1.    WARNING  Never use with a hardened mixing cannula     Note that while using bulk containers  the cans must be positioned at a height  higher than the device  Optional pad stands are available on request     Leave about 2 3 cm minimal filling inside the containers to avoid air to get into  the system and the need for demanding bleeding of the device              3 Application       Mixing and dosing of addition vulcanazing 1 1 two component silicones  For even dosage  of both components  both must have similar viscosity     Only use the device for this type of application           WASSERMANN    DENTAL MASCHINEN        Die Basis f  r Ihr Labor          4 Before starting         4 1 Transport    Before transporting the unit  ensure that it has been unplugged from the power socket   Make sure that it is packed correctly in order to avoid accidental damage       Be sure to check for any transport damage when unpacking the goods  Note down  any damage if found     4 2 Installation    Open the box  remove the packing materials  and carefully lift out the device and  accessories  Check the included accessories     Install the device on a stable  level surface   Do not install the SIDOMIX outdoors or in places without proper ventilation        Before start up  be sure the device reaches room temperature     Install the device in a place where it will not block the working area and the  functionality  take the dimensions into account      4 3 Storage    If the unit is to be stored 
2.   Only original spare parts are to be used  Responsibility for the product is voided      Servicing or repairs to the unit must only be carried out by qualified technicians     if unauthorised persons alter it or if inappropriate components are installed        12    WASSERMANN    DENTAL  MASCHINEN    Die Basis f  r Ihr Labor             9 Technical data         Mixing and dosing unit SIDOMIX  1 1     item no  172984    Dimension          width  290 mm  height  310 mm  depth  450 mm  Weight  11 5 kg  Voltage   220 240 V   50 60 Hz     115 V   50 60 Hz    Output  260 Watt     Other voltages upon enquiry        The noise level of the unit amounts to  lt  70 dB A      D The technical data are subject to change without prior notice        13    WASSERMANN    DENTAL  MASCHINEN        Die Basis f  r Ihr Labor             10 EC Conformity Certificate      in accordance with 2006 95 EG  low voltage guidelines  and 2004 108 EG  EMV  guidelines  and 98 37 EG  machinery guidelines        Manufacturer  WASSERMANN Product description  Mixing and dosing  Dental Maschinen GmbH unit  1 1  for  Rudorffweg 15   17 dental  D 21031 Hamburg applications  Model  SIDOMIX Item no  172984  Aapplicable DIN EN 61010 1 2004  standards  DIN EN 61000 6 3 2005    DIN EN 61000 6 1 2002  DIN 45635 1 1984  DIN EN 60335 1 2007    Hiermit wird best  tigt  dass die oben bezeichnete Maschine den genannten EG Richtlinien  entspricht  Diese Erkl  rung wird ung  ltig  falls die Maschine ohne unsere Zustimmung  ver  
3.  from the cans filled with two component silicone and screw  the adaptor set onto the cans   Warning  Screw the colour marked adapter onto the can filled with coloured  silicone compound     component B  Do not mix up  If you mix up the closings  even for a short time  the device must be disassembled and cleaned   Insert the can with quick closings into the entry on the back of the device  the can  will be upside down    Very important  Drill a ventilation hole using a drill or similar tool at the upper side  edge of the can to ensure proper ventilation        WASSERMANN    DENTAL MASCHINEN        Die Basis f  r Ihr Labor       When using 25 kg bulks    D Note that while using bulk containers  the cans must be positioned at a height  higher than the device  Optional pad stands are available on request   Remove the closings from the cans filled with two component silicone and screw  connection hoses onto the cans   Warning  Screw the colour marked connection hose onto the can filled with  coloured silicone compound     Component B   screw on  Do not mix up  If you  mix up the closings even for a short time  the device must be disassembled and  cleaned   Place the can  e g  on the optional pad stand  to make sure that it will be placed  higher than the dosage device  can will be upside down  and insert the connection  hoses with quick closings into the entry on the back of the device   Very important  Drill a ventilation hole using a drill or similar tool at the upper side  edg
4. 1  Pe lite 2                                                         4  2 Safety Quldelnes nen 4  2 1 Safety symbols used in this manual           cee eee cece eter nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 4  2 2 Safety guideline S sa cic ch ee ea ee 5  3 Applicaton een aD ee 5  4 Before SMO  Me ee een m 6  4 1 ICT 6  4 2 NS CAN AO sxc CT T                                          6  4 3 ro 6  5  6 M                                                 6  5 Startup Installati  n nennen erahnen 7  G OBEN anne ee Em 9  1 Troubleshooting em 2  222 2 ee 10  8 Care and mainlenance cs 11  SING ee euere era 11  8 2 SEPIC Hd nee 11  8 3 VV TAINLY ans tT                                      11  84 Spare paS  iena E eE e EE aa aa a eaaa E Eaa EES 11  8 5 Scope of delivery   Accessories 2  i EURO ao utes cepa a due ved Ub atas sue LEONE UU 12  Disi eR             X                                     12  9 Technical data ea een ee 13    TOE Conformity Certificate anne Re 14    WASSERMANN    DENTAL MASCHINEN        Die Basis f  r Ihr Labor          1 Features            Mixing and dosing of addition vulcanazing 1 1 two component silicones  For even dosage  of both components  both must have similar viscosity     Advantages     Mixing head with separate output openings     mixing of A and B components while  mounting or dismounting the mixing cannula is impossible      Automatic production of homogene silicone material without any loss or bubbles at the  press of a button      Saves material an
5. WASSERMANN  DENTAL MASCHINEN    Die Basis f  r Ihr Labor    Mixing and dosing unit  SIDOMIX       USER MANUAL    C     WASSERMANN DENTAL MASCHINEN GMBH    WASSERMANN    DENTAL MASCHINEN        Die Basis f  r Ihr Labor       Dear customer     Thank you for choosing a product from the Wassermann range  Wassermann dental  equipment incorporates the highest standards of quality and the latest technology    In order to enjoy maximum performance and years of trouble free operation  please read  this instruction manual carefully before you connect this device and start work  and  operate the device according to the recommended guidelines  The operation safety and  the functionality of this device can only be guaranteed if you follow both the general safety  guidelines and the applying laws to prevent accidents as well as the precautions given in  this instruction manual  We are not liable for any damages which occur due to  inappropriate usage or faulty operation of this device     e Make sure that anyone using this device has read and understood this instruction  manual     Keep this instruction manual in a safe place where it can be referred to as required  at any time     Company address    Wassermann Dental Maschinen GmbH   Rudorffweg 15 17   D 21031 Hamburg  Germany   Tel     49  0 40   730 926   0 Fax    49  0 40   730 37 24  E mail  info wassermann dental com   URL  http  www wassermann dental com    WASSERMANN    DENTAL MASCHINEN        Die Basis f  r Ihr Labor       Index  
6. d time by filling more than one bowl at the same time with just a single  mixing cannula      Forced mixing by a disposable mixing cannula  pink with bayonet mount    Containers with quick couplings mounted directly on the device      Quick coupling for mounting of 1 kg and 6 kg  optional adapter set   or 25 kg  optional  pad stand and adapter set with connection hoses required        The included 2x2 litre material containers feature a quick coupling and can be used  immediately       Food switch available as option       2 Safety guidelines    2 1 Safety symbols used in this manual    Warning   This is a warning of risk situations and dangers   Failure to observe this warning could be life threatening  These warnings must    be observed     e Information   This symbol draws your attention to specific features that must be observed        WASSERMANN    DENTAL MASCHINEN        Die Basis f  r Ihr Labor       2 2 Safety guidelines    connections  The mixing of components would cause the silicone within the  device to harden  making extensive repairs of the device in the Hamburg plant  necessary       Always keep the two silicone components separated     never mix up the    Drill a ventilation hole using a drill or similar tool at the upper side edge of the 1  litre bottle or 6 kg or 25 kg can  Do not tighten the caps of the 2 litre material  containers  but just fit them loosely to ensure proper ventilation    After hardening and before further usage  fit a new mixing cannula  
7. e of the can to ensure proper ventilation        Replacing bottles cans   Remove the quick coupling bottle adaptor from the device by pulling up the lock  Screw the  quick coupling bottle adaptor onto the new bottle can and connect as explained above        D Take special care to never confuse the bottles or connection hoses A B     not even  for a short time     since the silicone within the connections and pipes hardens  instantly  The cleaning procedure is very demanding and may only be performed by  authorised repair companies     Note that while using bulk containers  the cans must be positioned at a height higher than  the device  Optional pad stands are available on request       Never use with a hardened mixing cannula        WASSERMANN    DENTAL MASCHINEN           Die Basis f  r Ihr Labor          6 Operation               Switch on the device  the toggle switch lights green     To clean the pipes and dosage pump  perform the following upon first start up as  well as when replacing the bottles  Position a container under the mixing head  without the mixing cannula  press the red button and hold it until both components  run evenly and without bubbles from the mixing cannula adaptors     Mount the mixing cannula by turning it 90   on the mixing cannula adaptor  clean  the adaptor before if necessary   Place the bowl or the model to be used for  doubling the system under the mixing cannula  Press the red button  1 1 mixed  silicone runs out of the mixing cannula     W
8. e recommend collecting a small amount of the mixture initially output and just  letting the substance output subsequently run into the form  You can fill more forms  without changing the mixing cannula as long as the period between the single  dosage operations lies within the dripping time of the used silicone  about 4 min     The dosage machine 1 1 dispenses mixed silicone as long as you press the red  button     After use  leave the mixing cannula attached to the device and allow the remaining  silicone to vulcanise  This closes the openings of both components sufficiently     A new mixing cannula must to be fitted after hardening and before further usage   WARNING  Never use with a hardened mixing cannula     Very important    Do not continue operation if one or both containers are empty  otherwise the  pipes will convey air  observe the minimum liquid level of the containers    2 3  cm             WASSERMANN    DENTAL  MASCHINEN    Die Basis f  r Ihr Labor          7 Troubleshooting       No silicone output     No silicone output     No silicone output     No silicone output     Silicone output  without 1 1 ratio     Silicone output  without 1 1 ratio        Mixing head clogged     A and B component  was mixed up   silicone within the  device system has  hardened     Minimum liquid level  of the silicone  containers was  reached  system has  sucked in air     Silicone components  do not have similar  viscosity    Gears within the  pump are not evenly  worn     Clean mixi
9. ect condition  If faults occur which  could harm operators or third parties  the unit should not be used until it has been  fixed   This warranty does not cover damage caused by improper use  external  mechanical causes  transport damage or interference with the unit by unauthorized  persons     Wassermann Dental Maschinen GmbH does not accept any liability when using  silicone compounds produced by other manufacturers  Doubling silicones may vary  in viscosity and abrasiveness of both components  therefore not all commercially  available doubling compounds may be suitable for usage with this dosage device     8 4 Spare parts    If necessary please contact our service hotline phone   0049  0 40   730 92 6 0       11    WASSERMANN    DENTAL MASCHINEN       Die Basis f  r Ihr Labor       8 5 Scope of delivery   Accessories    Included parts   Material container set with quick coupling  2x2 litres    Mixing cannula  pink 100 pieces    Accessories    Mixing cannula  pink 100 pieces   Foot switch   Retrofitting set for foot switch   Material container set with quick coupling  2x2 litres   Pad stand small for WaSil   WaSil soft 2 x 6 kg bulk   Pad stand large for WaSil   WaSil soft 2 x 25 kg bulk  Connection hoses complete  2 pieces   Adaptor set for WaSil   WaSil soft 2 x 1 kg bulk    Adaptor set for WaSil   WaSil soft 2 x 6 kg bulk    8 6 Repairs    Part no     172640    622022    Part no     622022    174175    172630    172640    172631    172632    172633    172634    172636  
10. for an extended period  protect it from moisture and dust        WASSERMANN    DENTAL MASCHINEN        Die Basis f  r Ihr Labor          5 Start up   Installation               Connect the power cord     Remove the closing plugs from the connections and dosage head     When using 2 litre material containers  included        Fill the material container with the relevant component   Warning  Insert the container filled with coloured silicone compound      component B   into the colour marked entry at the back of the device  Do not  mix up  If you mix up the closings even for a short time  the device must be  disassembled and cleaned   Very important  Do not tighten the caps of the material containers  but just fit them  loosely to ensure proper ventilation        When using 1 kg bottles    iD Remove the closings of the bottles filled with two component silicone and screw the  above mentioned metal quick closings  accessories  onto the bottles   Warning  Screw the colour marked quick closings onto the bottles filled with  coloured silicone compound     component B  Do not mix up  If you mix up the  closings even for a short time  the device must be disassembled and cleaned   Insert the bottles with quick closings into the entry on the back of the device  the  bottles will be upside down    Very important  Drill a ventilation hole using a drill or similar tool at the upper side  edge of the bottles to ensure proper ventilation        When using 6 kg bulks    D Remove the closings
11. ndert wird     This is to confirm that the above mentioned machine complies with the described EC  rules  This declaration becomes invalid if the machine is modified without our approval     Cette machine est conforme aux normes en vigueur de la Communit   Europ  ene  Cet  avis est nul et non avenant si cette machine est modifi  e sans notre accord     Esta m  quina  anteriormente mencionada  cumple con los limites requeridos por el  reglamento EC  Ahora bien  esta declaraci  n quedar   invalidada en caso de realizar  modificaciones al aparato sin nuestra aprobaci  n     Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven    EU normen  Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke  toestemming wijzigen aan de machine worden aangebracht     Place  date  Hamburg  20 07 2007 Company stamp        Signature      Wilfried Wassermann   Managing Director        14    WASSERMANN    DENTAL  MASCHINEN    Die Basis f  r Ihr Labor       Notes        15    WASSERMANN    DENTAL MASCHINEN    Die Basis fur Ihr Labor        Wassermann Dental Maschinen GmbH  Rudorffweg 15 17   D 21031 Hamburg   Phone   49  0 40 730 926 0   Fax   49  0 40 730 37 24  info wassermann dental com    www wassermann dental com    
12. ng head carefully   Warning  Silicone components must not get  in contact with each other     The device needs to be disassembled and  cleaned by a qualified technician     Add silicone compound and wait about 20  min  until silicone fills the pipes  Position a  container under the mixing head without the  mixing cannula  press the red button and hold  it until both components run out even and  without bubbles from the mixing cannula  adaptors  Clean the mixing head and connect  a new mixing cannula if necessary     We recommend using Wassermann doubling  silicones WaSil soft and WaSil     The device needs to be inspected by a  qualified technician        If the above recommendations do not solve the problem  contact your dental  depot or our service department        10    WASSERMANN    DENTAL MASCHINEN        Die Basis f  r Ihr Labor          8 Care and maintenance            8 1 Cleaning    The identification plate must always be kept in easily legible condition and must      Disconnect the power plug before starting any maintenance work   not be removed     Always keep the mixing cannula adaptor and the quick closings clean   8 2 Servicing    The SIDOMIX does not require any servicing  Just make sure that the device is kept clean   8 3 Warranty    D The warranty period for our equipment is 12 months  If faults occur within the   warranty period  contact your dental depot or get in touch directly with our Service  department   Your equipment should only be operated in perf
    
Download Pdf Manuals
 
 
    