1. Pin Port Bit Type Pin Port Bit Type 1 C DO K1 Relay NC 23 A D3 Input 4 2 C D1 K2 Relay NC 24 A D3 Input 4 3 C D2 K3 Relay NC 25 A D4 Input 5 4 C D3 K4 Relay NC 26 A D4 Input 5 5 C D4 K5 Relay NC 27 A DS Input 6 6 C D5 K6 Relay NC 28 A DS Input 6 7 C D6 K7 Relay NC 29 A D6 Input 7 8 C D7 K8 Relay NC 30 A D6 Input 7 9 A DO Input 1 31 C DO K1 Relay NO 10 A DO Input 1 32 C DI K2 Relay NO 11 A D1 Input 2 33 C D2 K3 Relay NO 12 A DI Input 2 34 C D3 K4 Relay Common 13 A D2 Input 3 35 C D3 K4 Relay NO 14 A D2 Input 3 36 C D4 K5 Relay NO 15 No Connect 37 C DS K6 Relay NO 16 C DO K1 Relay Common 38 C D6 K7 Relay NO 17 C DI K2 Relay Common 39 C D7 K8 Relay NO 18 C D2 K3 Relay Common 40 A D7 Input 8 19 C D4 K5 Relay Common 41 A D7 Input 8 20 C DS K5 Relay Common 42 No Connect 21 C D6 K6 Relay Common 43 No Connect 22 C D7 K7 Relay Common 44 No Connect Sealevel Systems Inc 15 PLC 16 PCI User Manual Optional Terminal Block Kit Item KT108 Another option for termination of the PLC 16 PCI is the Terminal Block Kit Item KT108 This kit includes an HD44 Male to HD44 Female six foot cable Item CA185 and a 28 Pin Terminal Block Item TB08
2. Direct Hardware Control In systems where the user s program has direct access to the hardware i e DOS the table below gives the mapping and functions that the PLC 16 PCI provides Function Available Port Address Hex Port Type RD A Base 0 Input Port Opto Input B Base 1 Not Assigned RD WR C Base 2 Output Port Reed Relays D Base 3 Not Assigned RD Read RD WR Read or Write Reading the Inputs The inputs are active Low If no voltage is applied across one of the differential inputs it returns a binary one 1 on that bit If an AC or DC voltage is applied it returns a binary zero 0 on that bit Writing the Outputs The output ports are the only ports that can be written The relays on a standard PLC 16 PCI are normally open To close a relay a binary one 1 must be written to the appropriate bit Reading the Outputs The relay ports can also be read to determine the status of the various relays A read will return the ones complement or opposite of the value that is currently written to the port Sealevel Systems Inc 12 PLC 16 PCI User Manual Register Description All ports are set to input after reset or power up Address Mode D7 D5 D3 D2 D1 ie er for je aoa e pa ii ji pone Pee gt ii e mexa jiem jer jar ju fer fe e fe jar jar i PENR REN EOS EC EC DE KE IRC1 E Base 6 0 0 0 0 0 0 0 Ji Ki KR Gn 2422 KAN EGE PE Ba Interrup
3. INO 2NC C4 2NO DO SNC 01 SNO D2 ae ji INO gt RC 2 D4 ONC 7166 AND DE NE jz 6NO NC 7NO NE NC Normally Closed 8NO NO Normally Open RC Relav Common IC Isolated Input Common Sealevel Systems Inc 17 PLC 16 PCI User Manual Optional Cable Pin Assignments Item CA184 Part Number CA184 is an optional cable for use with the PLC 16 PCI The CA184 has an HD44 connector that breaks out to one DB37 Female connector for Inputs and one DB37 Male connector for Outputs This cable was designed to make our products more easily integrated into systems that may have previously used Sealevel legacy I O interface products The CA184 cable mimics several of the pin out options found on Sealevel PCI and ISA legacy products and provides a direct connection to the 37 pin Terminal Block Part Number TB02 KT The following tables show the pin out for this cable Input Port Pin Assignments DB37 Female Sealevel Systems Inc 18 PLC 16 PCI User Manual Output Port Pin Assignments DB37 Male GL RE e D3 K4 D5 K6 D6 K7 ren r J Sealevel Systems Inc 19 PLC 16 PCI User Manual Electrical Characteristics Features Specifications Sealevel Systems Inc 20 e 8 SPDT Form C relays e Eight optically isolated inputs e DB44 Female connector
4. SEALEVEL PLC 16 PC User Manual gt My G Ny Ra Dy ti 2 gt lt t ji Soe e ltem 8011 Sealevel Systems Inc Sealevel com Phone 864 843 4343 Table of Contents A Introductions natal site este tata zz g as ea di aeae eeaeee essor seset Other Sealevel PCI Digital I O Products 4 Before You Get Startedt c 5c c0cs40 0e0e504404004406000462040606030004605000 0006040600046044 0e 0604060030 40440000040600 00000406 0604066 D 5 What s Included Optional Items 5 Software Installation ii ii idi gi Windows 98 ME NT 2000 XP Installation 6 Linux Installation 7 Physical tistalla ON i i a neo d Programming the PEC T6 PC L e i e J Programming for Windows 9 Programming for Linux 9 Digital I O Interface 9 Input Port 10 Output Ports Form C Relavs 11 Output Port Pin Assignments HD44 Female 11 Direct Hardware Control 12 Reading the Inputs 12 Writing the Outputs 12 Reading the Outputs 12 Register Description 13 Interrupt Control 13 HD44 Female Pin Assignment 15 Optional Terminal Block Kit Item KT108 16 Silk Screen TBO8 Terminal Block 17 Optional Cable Pin Assignments Item CA184 18 Input Port Pin Assignments DB37 Female 18 Output Port Pin Assignments DB37 Male 19 Electrical Characteristics sissa ue a a aa a nn d a kesa DO Features 20 Sealevel Systems Inc 2 PLC 16 PCI User Manual SL9014 12 2013 Specifications 20 i 20178111 e KE e MY App
5. 003 x R Input Current input voltage 1 1V resistor value Maximum voltage 1 1 square root of 25 resistor value The following table shows the ranges associated with the resistor Note The turn off voltage for all resistors is less than 1V Because through hole resistors are utilized they cannot be easily replaced If modification is necessary Sealevel can do this for an additional charge Important The input circuits are not intended for monitoring 120 volt AC circuits In addition to being too high a voltage for the circuits it is dangerous to have that high a voltage on the card Sealevel Systems Inc 10 PLC 16 PCI User Manual Input Port Pin Assignments HD44 Female The inputs are not polarized and can be wired in either direction 9 10 11 12 w REM ee ML ZE a ae 29 30 40 41 Output Ports Form C Relays The PLC 16 PCI provides 8 Form C SPDT Electro mechanical relays These relays have three connections Normally Open NO Normally Closed NC and a Common The relays are all de energized at power on Data to the relays is latched by a write to the baset2 address On off status of the relays can be read back by a read at the base 2 address Output Port Pin Assignments HD44 Female Port C Bit Normally Closed Normally Open N NE E DI K2 D2 K3 D4 K5 D5 K6 a E EEE Sealevel Systems Inc JV lt PLC 16 PCI User Manual
6. detect the operating environment and install the proper components Next depending on your browser select the Run this program from its current location or Open option Follow the information presented on the screens that follow 7 A screen may appear with the declaration The publisher cannot be determined due to the problems below Authenticode signature not found Please select the Yes button and proceed with the installation This declaration simply means that the Operating System is not aware of the driver being loaded It will not cause any harm to your system 8 During setup the user may specify installation directories and other preferred configurations This program also adds entries to the system registry that are necessary for specifying the operating parameters for each driver An uninstall option is also included to remove all registry INI file entries from the system Windows NT Card Installation After accomplishing the above steps bring up the Control Panel and double click on the SealO Devices icon To install a new card click Add Port Repeat this procedure for as many SealO cards as you wish to install Sealevel Systems Inc 6 PLC 16 PCI User Manual Linux Installation Note You MUST have root privileges to install the software and drivers 1 2 Login as root Mount the CDROM by typing mount t iso4860 dev hdc cdrom Note Your cdrom may not be dev hdc it c
7. e PCI 2 1 Bus compatible Input Ports e Turn On Current e Isolator Diode Drop e Resistor Power Max e Maximum Input Range Output Relavs e Tvpe e Contact Max Power Rating e Contact Voltage Maximum e Contact Current Maximum e Contact Resistance Initial e Rated Life Mechanical Minimum Electrical Minimum e Contact Speed Operate Release Bounce Temperature Range e Operating e Storage Power Requirements e 5VDC 380mA 3mA 1 1 VDC 1 W 5 30 VDC VAC Bifurcated Gold clad silver palladium 30 W DC 60 VA AC 60 VDC VAC 2A AC DC RMS 100 10 Million Closures 5 Million Closures Full Load 2 mS 1 mS 7 mS 0 C 709C 509C 105 C PLC 16 PCI User Manual Physical Dimensions e PCB Length 4 9 12 4 cm e PCB Height 4 2 10 7 cm including Gold fingers Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask over tin nickel Sealevel Systems Inc 21s PLC 16 PCI User Manual Example Circuits Input Circuit input Input Port Bit Common Form C Output Circuit Normally Closed Common Normally Open Output Port Bit Sealevel Systems Inc 22 PLC 16 PCI User Manual Appendix A Troubleshooting Following these simple steps can eliminate most common problems
8. 1 Install software first After installing the software then proceed to adding the hardware This places the required installation files in the correct locations Read this manual thoroughly before attempting to install the adapter in your system Use Device Manager under Windows to verify proper installation Use the SealO Control Panel applet or the Device Manager s property page for card identification and configuration If these steps do not solve your problem please call Sealevel Systems Technical Support 864 843 4343 Our technical support is free and available from 8 00AM 5 00PM Eastern Time Monday through Friday For email support contact support sealevel com Sealevel Systems Inc 23 PLC 16 PCI User Manual Appendix B How To Get Assistance Begin by reading through the Trouble Shooting Guide in Appendix A If assistance is still needed please see below When calling for technical assistance please have your user manual and current adapter settings If possible please have the adapter installed in a computer ready to run diagnostics Sealevel Systems provides an FAQ section on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp Sealevel Systems maintains a Home page on the Internet Our home page address is http www sealevel com The latest software updates and newest manuals are available via o
9. KT The silk screen with diagram is shown on the following page The CA185 cable is wired straight through one to one The terminal block groups the common connections of the PLC 16 PCI into groups of four as shown e RCI Relay Common 1 ties together the ground pins for physical relays KI K4 logical DO D3 e g HD44 pins 16 17 18 and 34 are connected to simplify field wiring e RC2 Relay Common 2 ties together the ground pins for physical relays K5 K8 logical D4 D8 e g HD44 pins 19 20 21 and 22 are connected to simplify field wiring e The other eight screw terminals in each group 16 total are used to wire to the NO Normally Open or NC Normally Closed side of the relays These are labeled KI K4 and K5 K8 e ICI Input Common 1 ties together one side of the input pins for DO D3 and IC2 Input Common 2 ties together one side of inputs D4 D7 to simplify field wiring e The other four pins in each group 8 total are used to wire to the inputs These are labeled IDO ID3 and ID4 ID8 J m LS Un C Sealevel Systems Inc 16 PLC 16 PCI User Manual Silk Screen TBO8 Terminal Block The silk screen for the TB08 terminal block shows how the connections are labeled for ease in wiring and troubleshooting 90000000000000 e Seer eee x TB 8 Revision B INC Made in USA
10. PC case cover 3 Locate an available 5V PCI slot and remove the blank metal slot cover 4 Gently insert the PCI adapter into the slot Make sure that the adapter is seated properly 5 After the adapter has been installed the cables should be routed thru the opening in the bracket This bracket also features a strain relief function that should be used to prevent un expected cable removal 6 Replace the screw you removed for the blank and use it to secure the adapter into the slot This is required to ensure FCC Part 15 compliance 7 Replace the cover 8 Connect the power cord The PLC 16 PCI is now ready for use Sealevel Systems Inc 8 PLC 16 PCI User Manual Programming the PLC 16 PCI Sealevel s Seal O software is provided to assist in the development of reliable applications for the Sealevel Svstems familv of digital I O adapters Included on the Seal O CD are driver functions for use in accessing the I O as well as helpful samples and utilities Programming for Windows The Seal O API Application Programmer Interface provides a varietv of useful high level function calls implemented in a Windows dynamic link library DLL The API is defined in the help file Start Programs SealO SealO Help under Application Programmers Interface This help file also includes detailed information dealing with installation removal of the software and information about latencv logic states and device configu
11. best I O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured products We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field Sealevel products are designed and manufactured at its Liberty South Carolina facility allowing direct control over product development production burn in and testing Sealevel Systems Inc hereafter Sealevel warrants that the Product shall conform to and perform in accordance with published technical specifications and shall be free of defects in materials and workmanship for life In the event of failure Sealevel will repair or replace the product at Sealevel s sole discretion Failures resulting from misapplication or misuse of the Product failure to adhere to any specifications or instructions or failure resulting from neglect or abuse are not covered under this warranty Warranty service is obtained by delivering the Product to Sealevel and providing proof of purchase Return authorization must be obtained from Sealevel Systems before returned merchandise will be accepted Authorization is obtained by calling Sealevel Systems and requesting a Return Merchandise Authorization RMA number The Customer agrees to insure the Product or assume the risk of loss or damage in transit to prepay shipping charges to Sealevel and to use the original shipping container or equivalent Warran
12. an HD44 male connector that breaks out to 28 screw terminals e Cable and Terminal Block Kit Part Number KT108 Includes CA185 TB08 KT 6 Snap Track and DIN rail clips e DB44 Male to DB37 Male Female V Cable Part Number CA184 Optional cable for 8011 with a DB44 connector that breaks out to one DB37 Female connector for Inputs and one DB37 Male connector for Outputs e DB37 Male Female Terminal Block Part Number TB02 KT Break out serial and digital connectors to 37 screw terminals for easy field connection The TBO2 terminal block is designed with both DB37 male and female connectors therefore it can be used with any DB37 board regardless of the board s port gender e Cable and Terminal Block Kit Part Number KT109 Includes CA184 two TB02 KT 6 Snap Track and DIN rail clips Sealevel Systems Inc 5 PLC 16 PCI User Manual Software Installation Windows 98 ME NT 2000 XP Installation Do not install the Adapter in the machine until the software has been fully installed 1 Start Windows 2 Insert the Sealevel Systems CD in to your CD drive 3 If Auto Start is enabled for this drive the software will automatically launch Otherwise point your browser to the Index htm on the root directory of the CD 4 Select Install Software 5 Select the Part Number for your adapter from the listing 6 Select Windows 98 ME NT 2000 XP The setup file will automatically
13. ed in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likelv to cause harmful interference in such case the user will be required to correct the interference at the users expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission To obey these directives the following European standards must be met EN55022 Class A Limits and methods of measurement of radio interference characteristics of information technology equipment EN55024 Information technology equipment Immunity characteristics Limits and methods of measurement EN60950 IEC950 Safety of information technology equipment including electrical business equipment Warning This is a Class A Product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to prevent or correct the interference Always use cabling provided with this product if possible If no cable is provided or if an alternate cable is required use high quality shielded cabling to maintain compliance with FCC EMC directives Sealevel Systems Inc 26 PLC 16 PCI User Manual Warranty WARRANTY Sealevel s commitment to providing the
14. endix A Troubleshooting scsi alada i ed ailesel o ae Ga l AD Appendix B How To Get Assistance sssssnsssensszznssenesnnnoennssennosenesensoennseenseenosensoensoensoennos 24 Appendix C Silk Screen 8011 PCB cecccccccccocccoccoccocosocooccooosocooccososecooccoscsecosecoscsvosevos 25 Appendix D Compliance NOotiCces cocccocccccosccocoocosccoooocoocoooosecooccosescosccosesecosecoscovosvcos 25 Federal Communications Commission Statement 26 Warranty ie a a l G B Ta elite ni ta A Sealevel Systems Inc 3 PLC 16 PCI User Manual SL9014 12 2013 Introduction The PLC 16 PCI provides 8 Form C relays that can switch and carry 2A loads making it suitable for latching power data or other electronic signals for control applications Eight optically isolated inputs rated for 5 30V are also provided to allow monitoring of off board switch closures relays or for any other general purpose monitoring needs The PLC 16 PCI is optimized for 24V DC AC usage The board is PCI bus specification 2 1 compliant The PLC 16 PCI is designed to be used with a variety of Operating Systems including Windows 98 NT ME 2000 XP Linux and DOS The Seal O API Application Programmer Interface included on CD with the PLC 16 PCI provides a variety of useful high level function calls implemented as a Windows dynamic link library DLL and as a Linux kernel module and library In addition to the API Seal O includes sam
15. ould be dev hda dev hdb dev hdd or if you have a SCSI drive dev sda dev sdb dev sdc etc You may mount the CDROM to any location the cdrom is just a common example 3 Note Next change to the directory where you mounted the CDROM Ex cd cdrom software SealO Other linux The syntax is case sensitive Copy seaio tar gz to your home directory by typing cp seaio tar gz Change to your home directory by typing cd Unmount the drive and then Unzip and Untar the drivers and software by typing umount cdrom tar xvzf seaio tar gz Change to the SealO directory by typing cd SealO Now compile and prepare the drivers for use make install With the system off and unplugged install your SealO PCI card Plug system back in and boot Linux Login as root Load the driver by typing SealO load The driver has enabled the card and is ready to use and you now have the option to tun a test utility on it Skip to section Using the test software if you wish to do so at this time To set up Linux to automatically load the driver refer to a Linux manual concerning your specific distribution for help Sealevel Systems Inc 7 PLC 16 PCI User Manual Physical Installation The adapter can be installed in any 5V PCI expansion slot Do not install the Adapter in the machine until the software has been fully installed 1 Turn off PC power Disconnect the power cord 2 Remove the
16. ple code and utilities to simplify software development Other Sealevel PCI Digital I O Products PIO 24 PCI P N 8008 24 TTL Inputs Outputs PIO 32 PCI P N 8010 32 TTL Inputs Outputs PIO 48 PCI P N 8005 48 TTL Inputs Outputs PIO 96 PCI P N 8009 96 TTL Inputs Outputs DIO 16 PCI P N 8002 8 Reed Relay Outputs 8 Opto isolated Inputs REL 16 PCI P N 8003 16 Reed Relay Outputs DIO 32 PCI P N 8004 16 Reed Relay Outputs 16 Opto isolated Inputs ISO 16 PCI P N 8006 16 Opto isolated Inputs REL 32 PCI P N 8007 32 Reed Relay Outputs Sealevel Systems Inc 4 PLC 16 PCI User Manual Before You Get Started What s Included The PLC 16 PCI is shipped with the following items If any of these items is missing or damaged please contact Sealevel for replacement e PLC 16 PCI Adapter e Sealevel Seal O Software CD Optional Items Depending upon your application you are likely to find one or more of the following items useful for interfacing the PLC 16 PCI to real world signals All items can be purchased from our website http www sealevel com or bv calling 864 843 4343 e DB44 Male to DB44 Female 6 Cable Part Number CA185 High Densitv DB44 Male to Female extension cable e DB44 Male Terminal Block Part Number TB08 KT The TB08 KT designed for use with the Sealevel 8011 eases field wiring of 8 optically isolated inputs and 8 Form C relav outputs The terminal block has
17. r sensor and also isolated with respect to the host PC ground This means that signals such as low level AC line voltage motor servo voltage and control relay signals can be sensed or read by the PC without the risk of damage due to ground loops or ground faults Each sensor input pair has a current limiting resistor that is used to limit the input current to the opto isolator The opto isolator has two back to back diodes internallv This allows AC or DC signals to be sensed regardless of polaritv When the applied voltage is high enough to cause the led in the opto isolator to turn on the output of the opto isolator goes low O volts and the signal is read as a low logic level binarv 0 bv the PC When the input signal is too low to turn on the opto isolator the output goes high and the port bit is read bv the PC as a high logic level binarv 1 The input impedance of each isolated input is approximately 1K ohms factory default The opto isolator requires approximately 3mA to turn on The maximum input current is 50mA There are two things to consider when selecting the input resistor The first is turn on voltage for the circuit to sense and second is the maximum input voltage Maximum input voltage must not provide too much power to the input resistor and must also not overdrive the opto isolator input current specification The following formulas applv Turn on Voltage diode drop turn on current x resistance Ex 1 1
18. ration For C language programmers we recommend using the API to access the PLC 16 PCI If you are programming in Visual Basic using the ActiveX control included with Seal O is advised Samples and Utilities A variety of sample programs and utilities both executable and source code are included with Seal O Further documentation on these samples can be found by selecting Start Programs SealO Sample Application Description Information about where the files are phvsicallv stored on vour disk is also included in this same file Programming for Linux Seal O for Linux consists of two major parts a kernel module and a librarv The kernel module is a simple IO pass through device allowing the librarv to handle the more sophisticated functions provided to Seal O users It is provided in a tarball format and can easilv be compiled and included in the kernel build Digital I O Interface The PLC 16 PCI provides two parallel input output I O ports The ports are organized as ports A B C and D Port A is an input port interfaced to opticallv isolated inputs while port C is the relav output port Sealevel Systems Inc 9 PLC 16 PCI User Manual Input Port Port A is an eight bit input port connected to optically isolated input sensors Each sensor can be used to interface a voltage input and then sense whether the voltage is on or off Each sensor is isolated with respect to a common ground from every othe
19. t Control ADO 0 CDO 0 0 0 When enabled interrupts are generated on Port A bit DO IRQEN Interrupt enable 1 enabled 0 disabled 0 on power up IRCO Interrupt mode select see table below IRCI Interrupt mode select see table below Interrupt Mode Select Table Interrupt source is Base 0 bit DO When selecting the Interrupt Type always disable interrupts prior to changing or setting states This will help prevent inadvertent or unexpected interrupts from occurring IRCI IRCO Interrupt Tvpe 0 0 Low Level 0 1 High Level 1 0 Falling Edge 1 1 Rising Edge Warning When using the High and Low Level interrupts an interrupt occurs when input DO changes to either a High or Low state This will cause the computer to remain in an interrupt state until the input state changes Sealevel Systems Inc 13 PLC 16 PCI User Manual Interrupt Read Reading the Interrupt Status port Base 5 clears any interrupt pending IRQST DO Interrupt Status 1 interrupt pending 0 none Sealevel Systems Inc 14 PLC 16 PCI User Manual HD44 Female Pin Assignment The table below describes the pin out for the HD44 Female connector on the 8011 board The previous pages explain Port A Inputs and Port C Form C Relay Outputs addressing and how to read and or write to them
20. ty is valid only for original purchaser and is not transferable Sealevel Systems assumes no liability for any damages lost profits lost savings or any other incidental or consequential damage resulting from the use misuse of or inability to use this product Sealevel Systems will not be liable for any claim made by any other related party This warranty applies to Sealevel manufactured Product Product purchased through Sealevel but manufactured by a third party will retain the original manufacturer s warranty Sealevel Systems Incorporated 2779 Greenville Highway P O Box 830 Liberty SC 24857 USA 864 843 4343 www sealevel com FAX 864 843 3067 email support sealevel com Technical Support is available Monday Friday from 8 a m to 5 p m Eastern time Sealevel Systems Inc DT PLC 16 PCI User Manual Trademarks Sealevel Systems Incorporated acknowledges that all trademarks referenced in this manual are the service mark trademark or registered trademark of the respective company Sealevel Systems Inc 28 PLC 16 PCI User Manual
21. ur FTP site that can be accessed from our home page Technical support is available Monday to Friday from 8 00 a m to 5 00 p m eastern time Technical support can be reached at 864 843 4343 RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION RMA NUMBER Sealevel Systems Inc 24 PLC 16 PCI User Manual Appendix C Silk Screen 8011 PCB 4 2 see oocosoca CB A in ua B50000000 200000000 pooodooocooco DICODOOOVoooOoooo D i BEL op BEL ops 8 IE 19004 r BBBBBBBBBBB PLG 16 PGI User Manual ZAMM LM O SB tc 20000000 C18 SES a K mm 888888888 B59009099 RP1 12_ iz 14_ 15 Res vs si ol IO R3 oCo ra 8811 MER HA b oL Jors ol Jo F6 oL Jo oL Je ojo 6 k Jp iine mm U 25 Sealevel Systems Inc Appendix D Compliance Notices Federal Communications Commission Statement CE FCC This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and us

Download Pdf Manuals

image

Related Search

Related Contents

  Cisco Prime LAN Management Solution 4.1, License, 50 devices  INSCRIPTIONS AU LYCEE DU MONT BLANCx  インライン で粉 菱宏量を連続監視  Autonomia a due - SILVIO  Juror Notices Online User Guide - Northern Ireland Court Service  Omega Speaker Systems DPS3301 User's Manual  IUCLID 5 Guidance and Support    Dispositivo medico sterile monouso: Speculum vaginale  

Copyright © All rights reserved.
Failed to retrieve file