Home

영문 쥬라곤 고급형부화기 설명서 앞 - Poultry Supplies from

image

Contents

1. PX 20RD Rpt sd J KEON Digital Incubator www R com co kr USER S MANUAL Professional Incubator 1 Safety Cautions ACAUTION Be careful the details below when you use Do not use a damaged Do not pull the cord when power cord or loose taking out the power cord outlet and keep wet hands away from connecting plug Risk of electric shock or fire Never pull the plug out of Do not twist or crush Do not insert multiple the outlet during the electric cord connecting plugs in an incubation period outlet Risk of electric shock or fire Incubation will be interrupted Risk of electric shock or fire Risk of fire or electrical overload an Cautions al Be careful the details below when you use Do not install in dusty or Do not install under the dirty environment direct sunlight Do not install in moist or Do not install in excessively humid environment cold or hot conditions cigarette smoke etc Do not use any other non standard parts except those provided Risk of damage or fire within Risk of fire or interference with the incubator the incubation process Risk of fire or electric shock Risk of interference with Risk of damage or hatching the incubation process failure Do not cover the Install away from heat Ensure that the incubator is Do not turn the incubator ventilating opening sources installed on a stable surface upside down away from edges Do
2. For circulating warm air Tray Tray for Vermiculite incubation sand and reptile eggs Air inlet vent For inlet of air from outside View Window For a clear view of the incubation process duplicated View Window Water Cap jy To facilitate water top up for the humidity control Digital Control Center See description of the function and operation Locking Button Main Body 1 Main Body 2 3 Basic Components iii Main Body 1 Power Cord User s Manual Water Cap gt When the machine failed to power on even if you pluged in remove the fixing piece like the picture by screwdriver Insert the power cord in the socket at the back of the main body gt You can find assembled PCB when open the cover Remove faulty fuse with screwdriver gt Replace with new fuse 250V 2 0A 5 20mm Lock the three locking buttons at the front and rear of the incubator Ver E 3 2 6 Before use xe Environment conditions of the incubation room for the installation of reptile incubator Temp 22 25 C Humidity 30 50 If the incubation room temperature does not meet the required temperature it can not be controlled automatically with the set incubation conditions BRO nRa 900cc Room temperature should be about 4 lower than incubator setting temperature Figure 6 Figure 1 gt In case of low humidity incubation 7
3. 0 85 Fill the vermiculite incubation sand which is to be purchased separately into the small incubating tray as shown in Fig 1 gt In case of high humidity incubation 90 or more In case the incubating environment is to be maintained 90 or higher in humidity fill the small incubating tray with 900cc of water as shown in Fig 1 1 and put the vermiculite into it as shown in Fig 1 before mixing them That would facilitate the control of high humidity and remove the need of water filling 1 Before starting incubation fill water into the water tank of main body 2 as Fig 2 for humidification A Remove water from the tank before moving the incubator Otherwise the incubator can be out of order 2 Humidification heater part Fig 5 of the main body 1 should be soaked inside of water tank when assembling with main body 2 Be sure to check this and cover the view window for connecting power cord gt If you are going to incubate without water in the incubator you should turn off humidification function Refer to How to turn off Humidification Function ae Do not apply force or shock to heater on the upper part of the body lips It may be the cause of failure Some foreign body can be stick to the heater part after hatching but there is no problem Refer to the How to Clean 3 After setting the incubation environment of the egg install tray inside of the incubator and operate it for 30 to 40 minute
4. be naturally dried in order to remove moisture inside of the incubator Assemble the parts in the reverse order of disassembly gt In case of you operate humidification function there can be moss on the humidification heating part It doesn t effect in function and you just need to clean it with soft brush after hatching A Do not inflict an impact to the humidification heating part Or it will be damaged A Do not clean the product with organic solvents such as benzene and paint thinner 16 How to calibrate Temp Humidity This calibration function is to reset the temperature and humidity of the incubator to correct values using your thermometer and hygrometer It is better not to calibrate the incubator as normal thermometer and CAUTIONS hygrometer are not reliable than incubator factory setting How to calibrate Fill vermiculite to three fourths of the internal tray Fix temperature or hygrometer at 2 cm above Tinj the bottom of the tray and operate it for one hour before starting its calibration Be sure to check Z CAUTIONS before you calibrate temperature or humidity gt After start incubation press SET UP button and go to T CAL on incubation process If you press ENTER here WARNING will show on LCD It goes to calibration Mode automatically after 5 sec Then calibrate the temperature with UP DOWN button and press ENTER button for saving How to calibrate Humidity It is same with the way calibrating t
5. cubation environment press QUICK SET button to move to the next stage This will be converted to incubation screen after five seconds gt You shift to next mode with pressing QUICK SET button 1 to 4 times You can also use it when you want to check incubation conditions under incubation gt Auto Incubation Optimum incubation conditions for the species of reptiles are memorized in micro chip With this function you can easily operate this incubator Select the species of reptile at MENU screen with QUICK SET button and press ENTER button for about 2 sec for starting incubation gt Other Manual Incubation Other Manual incubation is for incubating the species of reptiles which is not memorized in the incubator User can set the incubation condition according to their needs LCD Display will indicate as the graph above Press MENU button at basic screen and select Others with UP DOWN button and then ENTER button Set the temperature humidity and daily temperature gap as your needs and press ENTER button gt What is Daily Temperature Gap Function This function is for making the incubation condition same with natural conditions It creats the highest temperature time zone by sun in nature artificially This function helps the hatching rate raise with optimum incubation conditions by the user directly set the proper temperature and time 12 How to turn off Humidification Function m gt You can turn off humidification fu
6. emp Gap Time Setting Screen in the day by user User can input temperature and time to make the optimum environments for incubation of reptiles Initial settings three hours i A Daily Temp Gap Temperature Setting It increases the daytime temperature by set temperature and the daytime period by set time 3 in the above STEP 3 In case of reptiles it is quite often to set the temperature higher than the incubation temperature by 1 5 C Initial settings depending on types of reptiles Eg In case of reptiles their incubation temperature is 26 1 C If the daytime period is set to three hours and daytime temperature to 1 5 C the incubation temperature changes from 26 1 C to 27 6 C for three hours once a day tots Hi Temp Set eae sor Z 0 0C 7 N START Hi Temp Set Daily Temp Gap Temperature Setting Screen gt QUICK SET button This button is used to reset the incubation environment temperature humidity daytime temperature during auto or manual incubation If QUICK SET button is pressed temperature window blinks in the incubation progressing screen When changing temperature set the temperature with up down button and press enter button after resetting It will be then stored and converted to incubation screen after five seconds ay Oy frees amp 26 1 c P24 Hour 80 Daily Temp Gap Setting Screen If you do not want to change the in
7. emperature on H CAL 17 Specification ii Power AC 100V 120V 50 60Hz AC 220V 240V 50 60Hz 40 95 ltcan be changed according to the conditions NetWeight 45K o O Size W 500X L 410X H 160 mm 250V 20A 5x 20mm Visit our web site www r com co kr for more information on our products and other informations Update of information download the necessary information from resource room in Recom homepage R com digital reptile incubator is designed for easy and convenient use For the improvement of the functions of the incubator design how to use etc can be changed without notice in advance am gt AUTO ELEX CO LTD www R com co kr www autoelex com e COMPANY 612 DukAm Ri JuChon Myeon GimHae City GyeongNam KOREA e TEL 82 55 337 2560 Direct to sales team 82 55 337 2561 3 2567 Office FAX 82 55 337 2568 e E MAIL auto autoelex com Sales team A Hatching result can be changed by a large number of factors Autoelex Co Ltd will not be held responsible for loss of eggs or reptiles under any circumstances such as hatching failure user s carelessness power failure or malfunction
8. etting 2 Humidity Setting OTHER MANUAL incubation UP DOWN button Selection of Reptiles Incubation Humidity Setting bay Temp Gap Seting 3 Daily Temp Gap Time Setting ENTER button 4 Daily Temp Gap Temperature Setting L Incubation starts MENU button Incubation completion UP DOWN button under incubation yes selection ENTER button incubation completion gt Incubation environments such as temperature humidity egg rotation etc are automatically controlled in automatic mode User only needs to select type of reptile User can change incubation environment if it is necessary SER Sue ral TEMPETON setting The reptile incubation temp on the menu screen is memorized in the micro chips User can optionally change the incubation temperatures Initial settings depending on types of reptiles Temperature Chameleon S 7 26 1 C l NEXT Temperature setting screen U A Humidity setting The reptile incubation Humidity on GMERZ Humidity 2 Cham eleon a NEXT Humidity setting screen the menu screen is memorized in the micro chips User can optionally change the incubation Humidity Initial settings depending on types of reptiles U Daily Temp Gap Time Setting U Hi Temp Cycle Daily Temp Gap function is to make the environment of incubator to be the hottest period Chame leon gt Hour l NEXT Hi Temp Cycle Daily T
9. nction when you don t fill water with your incubation or when you need low humidity incubaion under 40 gt Press QUICK SET button twice and ress DOWN button until OFF indicated at humidity setting Then press ENTER button OFF will show when the humidity is under 40 13 How to Terminate Incubation i gt If you press MENU button on incubation period System finish Are you sure messgae will show gt Select YES with UP DOWN button and then ENTER button If you leave the incubator alone without drying water after high humidity incubation the water inside of incubator condense and make waterdrop at the LCD display or control device For preventing this problem disassemble main body 1 and 2 and dry completely before storing You can dry the incubator as operating the incubator for about 1 to 2 hours after removing water 14 Incubator Initialization m ALL RESET For returning to the factory setting gt If you want to return to the initial set values please follow this sequence 1 Select All Reset at SET UP mode 2 Press Enter 3 Press OK 15 How to Clean after Hatching mamm gt Pull out the electric cord from connecting jack and also take out the plug from the outlet gt Unlock three of locking buttons at the front and back of incubator and disassemble the incubator gt Disassemble the incubator The bottom part shall be thoroughly cleaned with water and dried The upper parts shall
10. ng when you change the initial setting at discretion ERO Basic information of Incubator versoin Indication Professional A PX 20RD J profession ON Digital Incubator Rpt 44 www R com co kr Incubator 10 Easy Function Operation memm REFER TO HOW TO START INCUBATION FOR MORE INFORMATION Automatic Mode Gere Select omen Incubation the Species of Reptile D Sec Temp Setting the Species i Humid Setting of Reptile Daily Temp Gap Setting How to change Setting under Incubation case Aaa Seting QUICK SET Three times Daily Temp Gap setting Incubation Screen AE Select YES Termination on Incubation Are you sure Incubator Initialization Factory Setting CF How to change How to turn off S Humidification Function creen on Incubation In case of low humidity incubation 2 times UNDER 40 Other Manual Mode Incubation me D 337 5 K 807 aoc 55 5 By id etl eon poua Gham s PEA System finish 7 Alligator am HP ae GP amp YES oo Are you sure fe Ot e BCH MANU screen HOME screen before Screen showing starting incubation Screen showing incubation Screen showing incubation is in progress of other Reptiles is in progress completion of incubation QUICK SET button Selection of Reptiles Auto incubation p ENTER button Auto incubation starts after two seconds m Temperature setting Temperature Setting MENU button Incubation Temp Setting Humidity s
11. not install where children or other people can touch with easy Inner temperature can rise Risk of damage to the incubator Risk of damage to incubator Water will pour out of the incubator Risk of knocking the incubator interrupting incubation case and interference with and eggs and user from and view window can be dropped or accidental interference with the incubation process accidental knocks or drops or damaged the controls Do not disassemble or Please ensure that no modify the incubator in small objects get into any way the holes on the incubator If the incubator sounds strange or emits smoke contact your service center Clean the incubator If the incubator requires thoroughly before storing repair disconnect from the power supply and please contact to your service center Risk if electric shock or fire Risk of electric shock or fire Risk of electric shock or fire Be sure to disconnect the electric cord Cleaning Cautions ACAUTION from the outlet before cleaning Do not spray cleanser Clean the incubator by a directly on the incubator soft cloth with a neutral surface detergent Brush away dust on the plug with a dry cloth Do not use chemicals like wax benzene alcohol thinner aromatic or lubricant etc For special cleaning of inner part per year contact to the service center 2 identification of Parts Power Connecting For connecting power cord Vents for air circulation
12. play FAN Operation Display 3Hr Daily Temperature Gap Power Failure Notification 0 0 Setting Value Display Current Temperature Display ane ie g A 20 Acc Temperature Abnormal Display SS 55 Current Humidity Display 40 OFF Humidification function OFF 9 SET UP Other Functions a Daily Temperature Gap Operation Display TCAL Z WARNING Fatal Damage Pee with Incorrect Calibration A Be sure to read CAUTIONS Calibration available after 5 Sec Temp calibration limits 9 9 C 9 9 C H CAL Humidity AA WARNING Besureto read CAUTIONS Caiibration available ater 5 Sec Calibration with Incorrect Calibration Humidity calibration limits 20 20 ALARM Alarm sounds when incubator temp is higher than setting value Abnomal because of room temp change or heating system disorder High Alarm Setting Range 0 0 C 5 0 C Default Setting 0 0 C ALARM Abnomal low Alarm Alarm sounds when incubator temp is lower than setting value because of room temp change or heating system disorder Setting Range 0 0 C 5 0 C Default Setting 0 0 Selecting Centigrade C and Fahrenheit F Default Value Centigrade C LCD Backlight management setting Always On Always BackLight On Always Off Always BackLight Off EventOn 20 Sec ON with Key input Default Value Always On ON OFF Setting for Melody other alarms Default Value ON Babee ALL RESET It returns to factory setti
13. s and put eggs into the tray 4 Bury a low half of the eggs into the Vermiculite as Fig 1 and fix them Check the conditions of the eggs once a week Remove unfertilized eggs incompletely developed eggs eggs covered with mold 5 Check the water for humidification everyday and fill it up as shown in Fig 4 Stop supply of the water when styrofoam ball floats A Do not reuse Vermiculite incubation sand after hatch Humidification Figure 4 Heater Part ea Figure 5 If the incubation room is not properly controlled for high humidity 90 95 pour 75cc of water into four edges of the tray See Fig 6 And pour 1000cc of water at the main body 2 Fig 3 7 Operation Part m Menu Button Select Reptiles Incubation Termination MENU Select Button a e __ Select Auto Manual soc Pass to next stage Wa SETUPS Rotites incubator a ae A utomatic Temperature and Humidity Control amp Daily Temperature Gap Function Input Button Enter input value Pass to next stage Setting Value Check Function auton gt Other function display Return to previous stage 8 Display Part Explanation iis con naweanorunction con NAMEAND FUNCTION Others Fia l y Snake m4 Tortoise Reptile Icon Display SSS Heater Stop Display aS p Ci Ga Heater Operation Display uit ee Gecko SSS Humidification Stop Display een al op lt Humidification Operation Dis

Download Pdf Manuals

image

Related Search

Related Contents

Owner`s Manual  Franke ARX 160 D  Français langue seconde - immersion 11 et 12    Xenon Projector Installation Guide – 2006 Honda  Gigabyte GA-H81M-D3H motherboard  Installation and operating instructions KEMPER KHS Mini System  NOVO-500 / 900 / 1500 / 2500  none 100514319 Instructions / Assembly  NUK Babyphone 10.256.266 (BM  

Copyright © All rights reserved.
Failed to retrieve file