Home
20RS03-00 E3 User Manual
Contents
1. 21 Label giving the board s article number revision and serial number 22 Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 MEN Mikro Elektronik GmbH 20RS03 00 E3 2010 12 15 Pin assignment of the power supply 4 pin M12 connector 15 Pin assignment of the Ethernet 4 pin M12 connectors 16 Pin assignment of the service interface 8 pin M12 connector 17 Default switch configuration at startup 18 Ethernet port status LEDS 23 oett o re ete teed 19 Powersupply status LED 5 oui uui Ra eR t binetak itano 19 Service port 19 Error codes signaled via service port LEDs 19 13 1 System Overview 1 1 Layout of the RS3 Figure 1 The RSS front view System Overview Detachable bezel Detachable Pressure compensating valve e e e e e e o ETH 1 ETH2 ETH3 POWER e e e e e e ETH4 ETHS ETH 6 Mm oo oO oO 000 ETH 7 ETH 8 SERVICE 1 2 Pressure Compensating Valve The sealed housing of the RS3 makes a pressure compensating valve necessary to prevent stress on the unit s housing seals Its hydrophobic and oleophobic ePTFE membrane protects from the unit s interior from water and common automotive fluids and resists blocking after contact with common automotive fluids It protects against contamination from dirt dust salt and road debris dow
2. Remote monitoring RMON and alarm generation Displaying the running configuration in the form of CLI commands DHCP client server and relay Management interfaces through SNMP v3 WebUI HTTP and HTTPS SSL Switch configuration can be loaded from external dongle Management Firmware Layer 2 Features TCP IP IPv4 IPv6 Transparent bridging QoS DiffServ and 802 1p traffic prioritization queuing polishing shaping VLAN aware bridging with GARP Static and dynamic VLANs through GVRP Dynamic learning of multicast groups through GMRP Rapid Spanning Tree Protocol and Multiple Spanning Tree Protocol to ensure loop free topology formation Reducing multicast traffic in the network through multicast snooping IGS IPv4 and MLDS IPv6 IGMP proxy Aggregating physical ports for increasing bandwidth and redundancy through link aggregation LACP Link Layer Discovery Protocol LLDP SNMP v1 v2c v3 agent and MIB support configuration save restore MEN Mikro Elektronik GmbH 3 20RS03 00 ES 2010 12 15 Technical Data Management Firmware Security Features User authentication using 802 1x Controlling management access through SNMP CLI and web only from autho rized managers MAC based access list ACL for traffic filtering Rate limiting and storm control to prevent packet flooding from malicious peers Supported Ethernet Standards Transparent bridging IEEE 802 1d 2004 VLAN IEEE 802 1q Rev D5 0 2005 Port bas
3. and three for the service port status The LEDs act as described in the following tables Table 5 Ethernet port status LEDs LED Description LNK Ethernet link status ON link established Q ACT Ethernet traffic activity status ON Ethernet traffic running Table 6 Power supply status LED LED Description PWR Input power status ON valid range Table 7 Service port LEDs LED Description RST Reset LED ON reset active e S 1 Micro controller LED function depends on software 2 Micro controller LED function depends on software The micro controller uses the service port LEDs connected to it to indicate the reason for an error during startup The status LED will blink or light up as listed in Table 8 Error codes signaled via service port LEDs until the system is restarted or completely powered off The supported error codes are as follows Table 8 Error codes signaled via service port LEDs Failure source os s RS232 UART fast fast Memory fast slow Marvell switch access slow fast Marvell switch internal PHYs slow on External PHYs slow slow Temperature sensor on fast IDPROM on on PoE on slow Firmware image off on Unspecified off fast Slow means blinking with a frequency of 1 Hz fast means blinking with a frequency of 10 Hz MEN Mikro Elektronik GmbH 19 20RS03 00 E3 2010 12 15 Mounting Opti
4. by a slash indicate that this signal is IRQ either active low or that it becomes active at a falling edge in out Signal directions in signal mnemonics tables generally refer to the corresponding board or component in meaning to the board or component out meaning coming from it Vertical lines on the outer margin signal technical changes to the previous issue of the document MEN Mikro Elektronik GmbH 9 20RS03 00 E3 2010 12 15 About this Document Legal Information MEN Mikro Elektronik reserves the right to make changes without further notice to any products herein MEN makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose nor does MEN assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability including without limitation consequential or incidental damages Typical parameters can and do vary in different applications All operating parameters including Typicals must be validated for each customer application by customer s technical experts MEN does not convey any license under its patent rights nor the rights of others Unless agreed otherwise MEN products are not designed intended or authorized for use as components in systems intended for surgical implant into the body or other applications intended to support or sustain life or for any other application in which the failur
5. female D coded CONEC SAL 12D FKH4 2 P12 9 43 01248 Mating connector e g Harting 21032811405 R410925 Table 2 Pin assignment of the Ethernet 4 pin M12 connectors Pin Name Description i 1 TX Transmitter positive output S 2 RX Receiver positive input EV JB 3 TX Transmitter negative output a 4 RX Receiver negative input Each of the Ethernet ports has its own MAC address etc The unique MAC address is set at the factory and should not be changed Any A attempt to change this address may create node or bus contention and thereby render the switch inoperable The MAC addresses on the RS3 are LANI Ox 00 CO 3A AO xx x0 Ox 00 CO 3A A3 xx x0 LAN2 Ox 00 CO 3A AO xx x1 Ox 00 CO 3A A3 xx x1 LANS8 0x 00 CO 3A AO xx x8 0x 00 CO 3A A3 xx x7 where 00 CO 3A is the MEN vendor code A is the MEN product code the following four digits depend on the the serial number of the unit and the last digit corresponds to the interface 0 to 7 for ports 1 to 8 respectively xx xx is the hexadecimal serial number of the product which depends on your board e g 0x 00 2A for the serial number 000042 Example Port 2 of the unit with the serial number 0042 0x 00 2A has the MAC address Ox 00 CO 3A AO 02 Al For the unit s overall serial number please refer to Chapter 3 2 Finding out the Board s Article Number Revision and Serial Number on page 22 MEN Mikro Elektronik GmbH 16
6. 20R 03 00 E3 2010 12 15 R 3 Rugged niPios Managed Ethernet Switch Configuration example User Manual man mikro elektronik gmbh n rnberg RS3 Rugged MIPIOS Managed Ethernet Switch RS3 Rugged MIPIOS Managed Ethernet Switch The RS3 is a rugged IP67 stand alone managed Fast Ethernet switch It provides eight Ethernet channels on M12 connectors The switch supports full duplex and half duplex operation with auto negotiation high speed non blocking store and forward switching Quality of Service QoS support with four traffic classes IEEE 802 1p and three level 802 1x security as well as the logical segmentation of ports 802 1q VLANs The switch is fault tolerant and restores itself on its own If a link is temporarily unavailable frames can be sent via backup redundant links spanning tree protocol link aggregation and no data loss occurs Its built in test mechanisms make the RS3 an even more reliable component in the communication system A service port is accessible at the front panel on an M12 connector providing an easy way to configure the switch A command line interface is available via the RS232 at the service port and over Ethernet via Telnet or Secure Shell SSH The switch can also be configured via SNMP version 3 and through its HTTP web server Additionally the service connector can be used to attach an external dongle to store or update the switch configuration This mak
7. 20RS03 00 ES 2010 12 15 1 4 3 The service connector features an RS232 System Overview Service Interface RS232 I2C UART interface for maintenance purposes Further information about maintenance and configuration options is provided in the documentation of the RS3 firmware An I C connection is also available to connect an external dongle available from MEN for easy dumping or uploading of configuration data Connector types e 8 pin M12 connector female A coded CONEC SAL 12 FKH8 P12 9 43 01064 Mating connector e g CONEC SAL 12S RS8 2 G3 43 10980 Table 3 Pin assignment of the service interface 8 pin M12 connector Pin Name Description 1 3 3V Power supply for external dongle 2 RS232_RX RS232 receive data T 3 RS232_TX RS232 transmit data j 4 GND Ground l 2 5 SDA IC serial data input output for external dongle 5 ij General purpose I O 1 Apply active signal for more than 2 seconds 6 GPIO 1 Reset Apply active signal for more than 10 seconds Reset with restored factory settings 7 SCL 12C data clock for external dongle General purpose I O 2 8 GPIO 2 Used for detection of external dongle MEN Mikro Elektronik GmbH 20RS03 00 E3 2010 12 15 System Overview 1 5 Ethernet Switch The RS3 uses a manageable 8 port 10 100Base T switch component the Marvell 88E6095 The switch provides 10 100 Mbits s configuration possibility on each of
8. be complete it must have 9 characters Revision number Gives the hardware revision of the board Serial number Unique identification assigned during production If you need support you should communicate these numbers to MEN Figure 5 Label giving the board s article number revision and serial number Complete article number Article No O 06RS03 00 Serial No 000000 3 Serial number Rev 00 00 00 Revision number men MEN Mikro Elektronik GmbH 22 20RS03 00 E3 2010 12 15
9. demarks service marks or product names as designated by the companies who market those products The trademarks and registered trademarks are held by the companies producing them Inquiries concerning such trademarks should be made directly to those companies All other brand or product names are trademarks or registered trademarks of their respective holders Information in this document has been carefully checked and is believed to be accurate as of the date of publication however no responsibility is assumed for inaccuracies MEN Mikro Elektronik accepts no liability for consequential or incidental damages arising from the use of its products and reserves the right to make changes on the products herein without notice to improve reliability function or design MEN Mikro Elektronik does not assume any liability arising out of the application or use of the products described in this document Copyright 2010 MEN Mikro Elektronik GmbH All rights reserved S Please recycle Germany France USA MEN Mikro Elektronik GmbH MEN Mikro Elektronik SA MEN Micro Inc Neuwieder Stra e 5 7 18 rue Ren Cassin 24 North Main Street 90411 Nuremberg ZA de la Ch telaine Ambler PA 19002 Phone 49 911 99 33 5 0 74240 Gaillard Phone 215 542 9575 Fax 49 911 99 33 5 901 E mail info men de www men de MEN Mikro Elektronik GmbH 20RS03 00 E3 2010 12 15 Phone 33 0 450 955 312 Fax 33 0 450 955 211 E mail info men france fr www men france
10. ding to class Tx EN50155 Airflow natural convection Temperature range storage 40 85 C Relative humidity operation max 95 non condensing Relative humidity storage max 95 non condensing Altitude 300 m to 3 000 m Climatic tests according to EN50155 and EN68068 Shock and vibration tested according to EN61373 IP67 compliant Conformal coating on request Safety PCBs manufactured with a flammability rating of 94V 0 by UL recognized man ufacturers EMC Tested according to the following railway standards EN50121 radio disturbance EN61000 4 2 ESD EN61000 4 3 radiated disturbances EN61000 4 4 burst EN61000 4 5 surge Conforming to el requirements of the German Federal Motor Transport Author ity Tested according to the following automotive standards CISPR25 CISPR16 radiated emission ISO7637 2 conducted emission power line I807637 2 conductive immunity power line I807637 3 capacitive immunity signal line ISO11452 2 ISO11452 5 radiation immunity EN50121 radio disturbance Firmware Firmware for configuration and management included e For more information on supported operating system versions and drivers see online data sheet MEN Mikro Elektronik GmbH 5 20RS03 00 ES 2010 12 15 Block Diagram Block Diagram gt Front Ae connector Power Supply Local Supply 1 Options lt P Uni Voltage A nit Power Supervisor Configurati
11. e of the MEN product could create a situation where personal injury or death may occur Should Buyer purchase or use MEN products for any such unintended or unauthorized application Buyer shall indemnify and hold MEN and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim of personal injury or death associated with such unintended or unauthorized use even if such claim alleges that MEN was negligent regarding the design or manufacture of the part Unless agreed otherwise the products of MEN Mikro Elektronik are not suited for use in nuclear reactors or for application in medical appliances used for therapeutical purposes Application of MEN products in such plants is only possible after the user has precisely specified the operation environment and after MEN Mikro Elektronik has consequently adapted and released the product ESM ESMini MDIS MDIS4 MDISS5S MENMON M Module M Modules SA Adapter SA Adapters UBox USM and the MBIOS logo are trademarks of MEN Mikro Elektronik GmbH PC MIP is a registered trademark of MEN Micro Inc and SBS Technologies Inc MEN Mikro Elektronik ESMexpress MIPIOS and the MEN logo are registered trademarks of MEN Mikro Elektronik GmbH All other products or services mentioned in this publication are identified by the tra
12. ed VLANs IEEE 802 1q Rev D5 0 2005 GVRP GMRP support IEEE 802 1d Rapid Spanning Tree Protocol IEEE 802 1d Multiple Spanning Tree IEEE 802 1s IEEE 802 1q Rev D5 0 2005 IGMP snooping draft ietf magma snoop 12 txt MLD snooping draft ietf magma snoop 12 txt Link aggregation IEEE 802 3ad 2005 Port based authentification with EAP IEEE 802 1x REV2004 Link Layer Discovery Protocol IEEE 802 1ab 2005 Priority based switching IEEE 802 1p Service Interface M12 connector at front RS 232 V24 PC interface for external dongle Front I O 8 Ethernet ports via M12 connectors 1 service interface via M12 connector 1 power input via M12 connector Link and activity Ethernet status LEDs 2 per channel Status LEDs for power reset and error codes Electrical Specifications Power input Nominal input voltage 24 VDC 9 to 36 V according to EN50155 EN50155 power interruption class S2 Isolation according to EN50155 1500 Vrms Power consumption 5 W MTBF Approx 200 000 h tbc 40 C according to IEC TR 62380 RDF 2000 MEN Mikro Elektronik GmbH 4 20RS03 00 ES 2010 12 15 Technical Data Mechanical Specifications Dimensions 220 mm x 130 mm x 70 mm without connectors Prepared for wall or DIN rail mounting with special mounting plates available separately Weight 1 9 kg Environmental Specifications Temperature range operation 40 70 C 85 C with up to 85 C for 10 minutes accor
13. es it easy to exchange the unit for service purposes The RS3 a member of the MIPIOS family of extremely rugged IP67 compliant products designed for Ethernet connectivity and highly demanding applications e g for redundancy systems The industrial grade unit is fully compliant with EN 50155 railway standard All components inside the enclosure are specified for 40 85 C operation thus enabling the device for EN 50155 class Tx operation Additionally the device is e1 certified by the German Federal Motor Transport Authority Convection cooling is sufficient There are no socketed components hardening the box against shock and vibration The internal electronics are prepared for conformal coating The Ethernet switch is prepared for wall or DIN rail mounting MEN Mikro Elektronik GmbH 2 20RS03 00 ES 2010 12 15 Technical Data Technical Data Switch Fabric Key Features Eight 10 100Base T ports at front panel Electrical isolation 1500 Vrms Auto negotiation High speed non blocking store and forward switching 8K MAC address lookup table with automatic learning and aging QoS Quality of Service support with 4 traffic classes IEEE 802 1p tagged frames Layer 2 switching Back pressure or IEEE802 3x flow control Automatic MDI MDI X crossover all ports Management Firmware System Features Saving and restoring user configurations Software upgrades through TFTP System logs syslog and e mail alerts for critical events
14. fr Fax 215 542 9577 E mail sales menmicro com www menmicro com Contents Contents 1 System Overviews codecs bias sar oeosues tae nee Shas oe eons seu 14 LI Eayoutolihe R93 2552392 04m 9 0442 99 a dubi Uu o abd e baad 14 1 2 Pressure Compensating Valve 0 0 14 1 3 Baith COBHeGHOf s vua acted can cae GI ERURERURS ER SORT OLI ECD dosis 14 1 4 terfacesu ius cae then ur Y 244d ORE aad EN Ee aS ORE POE e Re 15 LI Power Inputs cue sesties pitini siege Satie aie 15 1 4 2 BEthernet Interface ioo eee nae d earmnaians caia s anges 16 1 4 3 Service Intertace RS232 DC 62 1 594 eR RR 17 LS Bihernet SWIC ican ax getex ti p geo aan pado ar e aloes 18 1 5 1 Configuration of the Switch 2er tme e 18 1 6 Front Panel Status LEDS 19 2 Mounting Opti nS 662 eh o rh e sete e res rh RR rss 20 2 1 Mounting the RSI 1o bnss aee eds eet tera eda 20 3 Appendix 5265 vEE ep pex eps n ERE ELSE UU URP DM eV eus 22 3 1 Literature and Web Resourcess eese 22 3 2 Finding out the Board s Article Number Revision and Serial Number22 MEN Mikro Elektronik GmbH 20RS03 00 E3 2010 12 15 Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 MEN Mikro Elektronik GmbH 20RS03 00 E3 2010 12 15 The RSS ODL VIEW 14 Earth connection and pressure compensating valve 14 Mounting the RS3 to the DIN rail mounting plate 20 Mounting the RS3 to the wall mounting plate
15. n its original ESD protected packaging Retain the orig inal packaging in case you need to return the board to MEN for repair MEN Mikro Elektronik GmbH 20RS03 00 ES 2010 12 15 About this Document About this Document AN This user manual describes the hardware functions of the switch and connection of peripheral devices It also provides additional information for special applications and configurations of the unit The manual does not include detailed information on individual components data sheets etc A list of literature is given in the appendix History Issue Comments Date E1 First issue 2010 11 26 E2 Removed mention of SIL4 from product description 2010 12 13 E3 Reworked block diagram config EEPROM and 2010 12 15 CPU switch device connection Conventions This sign marks important notes or warnings concerning proper functionality of the product described in this document You should read them in any case italics Folder file and function names are printed in italics bold Bold type is used for emphasis monospace A monospaced font type is used for hexadecimal numbers listings C function descriptions or wherever appropriate Hexadecimal numbers are preceded by Ox hyperlink Hyperlinks are printed in blue color The globe will show you where hyperlinks lead directly to the Internet so you can look for the latest information online IRQ Signal names followed by or preceded
16. n to 0 07 um 1 3 Earth Connection An earth connection can be established via the respective screw hole on the right side of the unit below the pressure compensating valve Use an M4 screw Figure 2 Earth connection and pressure compensating valve MEN Mikro Elektronik GmbH 20RS03 00 E3 2010 12 15 Pressure compensating valve Screw hole for earth connection System Overview 1 4 Interfaces 1 4 1 Power Input The RS3 usually comes with an internal 24 VDC nom 9 to 36 V wide range power supply led to a 4 pin M12 connector RS3 models models with other input voltage ranges are also available from MEN to suit individual projects needs The internal power supply is EN50155 compliant which implies that it has a built in power on threshold of 0 7xUn 16 8 V Once the unit is turned on the input voltage may drop as low as 9 V Connector types 4 pin M12 connector male A coded CONEC SAL 12 FSHA P12 9 43 01066 Mating connector e g CONEC SAL 12 RK4 2 A1 43 10020 Table 1 Pin assignment of the power supply 4 pin M12 connector Pin Name Description 7 1 VBAT Positive input 2 VBAT Positive input C i 3 VBAT Negative input 4 VBAT Negative input MEN Mikro Elektronik GmbH 15 20RS03 00 ES 2010 12 15 System Overview 1 4 2 Ethernet Interface The RS3 comes with eight Fast Ethernet ports on 4 pin female M12 connectors Connector types 4 pin M12 connector
17. on EEPROM Switch Device Management 10 100Base T CPU Service Port MEN Mikro Elektronik GmbH 6 20RS03 00 E3 2010 12 15 Configuration Options Configuration Options Ethernet Switch Functions Mechanical Specifications 4 Ethernet ports Electrical Specifications Other nominal input voltages 36 48 72 96 or 110 VDC Wide input range according to EN50155 0 7 x nominal voltage nominal voltage 1 25 x nominal voltage Please note that some of these options may only be available for large volumes Please ask our sales staff for more information For available standard configurations see online data sheet MEN Mikro Elektronik GmbH 7 20RS03 00 E3 2010 12 15 Product Safety Product Safety A Electrostatic Discharge ESD Computer boards and components contain electrostatic sensitive devices Electrostatic discharge ESD can damage components To protect the board and other components against damage from static electricity you should follow some precautions whenever you work on your computer Power down and unplug your computer system when working on the inside Hold components by the edges and try not to touch the IC chips leads or cir cuitry Use a grounded wrist strap before handling computer components Place components on a grounded antistatic pad or on the bag that came with the component whenever the components are separated from the system Store the board only i
18. ons 2 Mounting Options 2 1 Mounting the RS3 The RS3 is designed for mounting using one of two mounting plates a DIN rail mounting plate or a wall mounting plate available separately from MEN To attach the unit to the mounting plate remove the detachable bezel at the sides of the front panel to access the four holes two on each side reserved for the necessary screws as pictured above and below Figure 3 Mounting the RS3 to the DIN rail mounting plate Detachable bezel MEN Mikro Elektronik GmbH 20 20RS03 00 E3 2010 12 15 Mounting Options Detachable bezel Make sure to use the following screw types in the process A To fix the RS3 to the mounting plate 4 DIN 7985 M4 x 20mm A2 screws 4 MA washers To fix the wall mounting plate to the wall 4 DIN7985 M5 x min 12mm A2 screws 4 M5 washers MEN Mikro Elektronik GmbH 21 20RS03 00 E3 2010 12 15 Appendix 3 Appendix 3 1 Literature and Web Resources e RS3 data sheet with up to date information and documentation www men de products 06RSO3 html 3 2 Finding out the Board s Article Number Revision and Serial Number MEN user documentation may describe several different models and or hardware revisions of the RS3 You can find information on the article number the board revision and the serial number on two labels attached to the board Article number Gives the board s family and model This is also MEN s order ing number To
19. the eight Ethernet ports It is also possible to configure each port in half duplex or full duplex The device characteristics are 8 external ports configurable as 10 100 Mbits s MII interface Each external port is configurable in half duplex or full duplex mode Non blocking wire speed switching Store and forward mode Auto negotiation Port mirroring Port monitoring Flow control VLAN support Automatic MDI MDI X crossover all ports Port based frame priorization 1 5 1 Configuration of the Switch The RS3 loads the following standard configuration for all ports at startup Table 4 Default switch configuration at startup Setting Default Duplex mode Full Duplex Port speed Auto Negotiate VLAN port based Off QoS Quality of Service Off Port mirroring and port monitoring Off Port trunking Off All of the ports are individually configurable using an external dongle a command line interface via RS232 through the M12 service connector Telnet or Secure Shell SSH via SNMP Version 3 or via the unit s HTTP web server Further information about configuration options is provided in the documentation of the RS3 firmware MEN Mikro Elektronik GmbH 18 20RS03 00 E3 2010 12 15 System Overview 1 6 Front Panel Status LEDs The standard RS3 features a total of 20 status LEDs at its front panel Sixteen for the Ethernet port status two for each port one for the supply status
Download Pdf Manuals
Related Search
Related Contents
Code produit : 75041U EMFIPARQUET PRO ECO R8C/1A, R8C/1B Group Hardware Manual LifeSize ExpressTM-Installationshandbuch 1/2" impact wrench kit instruction manual manuel d`utilisation pour Good Usage Guide & Troubleshooting VIVID SERVICE MANUAL istisbl3kmc30 0.0.pmd Télécharger en PDF - Boulogne HP BMD00022 User's Manual Copyright © All rights reserved.
Failed to retrieve file