Устройство водяного охлаждения - чиллер SunRise PH-LW15-BLP

image

Contents

1. l Technical SUPPORT PE SS 16 7 1 Circuit diagram 7 2 Cooling system diagram 1 General information 1 1 Touser Thank you for choosing SUNRISE laser chiller Please read the manual thoroughly before operating the machine Please keep your manual receipt AC pass and warranty card for further use Don t spoil any label on the machine so that you can enjoy our service Please contact your local dealer or our service center if you need any further help This manual is only apply in our standard model only reference for customized model 1 2 Unpacking Your chiller is packed in special carton package please reserve the carton and other packing stuff before you can make sure chiller is running properly If the chiller doesn t work the chiller could be replaced for a new one within 7 days after you receive the chiller If you have found any damage in the delivery please contact logistic company and your local dealer for submitting damage claim This sign marked all Safety related chapter in this manual the sign marked on the machine is reminding for safety operation This sign means high voltage danger Please read all the instructions on safety notice and operation carefully Notes Uint conversion table 1 Cooling capacity 1W 3 44BTU h 1W 0 86Kcal h 60HZ 50HZ refrigeration cooling capacity is about equal to 1
2. LW15 BLP 17A Circuit Diagram NTC2 NICI Cooling magnetic vaive DY2 Bypass magnetic valve Water pump Flow switch Fan Capacitor COM Compressor C MP MF FS DY1 gt rej N Sa lt 16 T u 5 m ooking Inner Thread DN15 1 2 Drain Inner Thread DN15 1 2 operatio LXWXH mm 330X450X600 NOTE Water temp stability is 0 5 C the max ambient is 400 Watet temp setting range from 5to25C The filer is made of polypropylene and the filtration hole is 5u min diameter Nominal working condition Abore technical parameter is based on ambient temp 30 C outprt water temp 250 All the specifications are srbjected to revise without further Notice 4 2 4 Dimensions Note No filter TATTOO LLL La TE A ND HT min i i ss S x s M SHAHN KA SNN ee k 6 Trouble shooting Warning For gualified staff only danger voltage exists after power on 6 1 System not working No cooling or pump not working Whether the power wire is connected to the socket Whether the power is ready Whether the power switch on the panelis on 6 2 Pump not working properly Check water level whether the pump is pumping water or not Check whether the motor of the pump is working Check whether the recirculation system is blocked 6 3 Pump insufficient pumping Please check whether the voltage is
3. suffocation hazard caused by gas leakage 3 Make sure the machine is properly grounded Electric shock may occur if the machine is installed without grounded Don t stretch anything into the equipment The high speed fan will be damaged by foreign material In case of abnormal running appear cut off the power contact our local dealer for instructions Fire hazard electric shock etc might occur if keep running the machine under abnormal conditions Don t operate the machine with wet hands Electric shock may occur Don t repair the chiller by yourself In safety sake please ask our dealer or a professional staff to repair it Don t install the chiller in a flammable and explosive place Neutral liquid and liquid whose gravity and heat transmission are similar with water are required in order to protect the water pump water with solid particles are not allowed when replace the liquid please note the pump can t be run without water In cold areas proper anti freezing measures should be done Warning please cut off the power before installation 3 2 Site reguirements Ambient temperature and relative humidity RH Our chiller suitable for install indoors ambient temp from 5C to 35C RH less than 80 No condensation Location The chiller should be installed on solid horizontal surface the closer to the laser equipment the better cooling performance will achieve keep the chil
4. too low Please check whether the diameter of the pipe is too small Please check whether the fluid viscosity is too high Please check the connection tube carefully 6 4 insufficient cooling or No cooling Please check whether the voltage is too high or too low Please check whether the air discharge side has been blocked Please check ambient temp high ambient temp will make the compressor halt for a short time Solution for no error codes display I Insufficiency cooling O Please check whether the condenser radiator and air filter is dirty Whether the temp of the installation site is too high and ventilation condition is bad Slightly refrigerant leakage E3 error has been reported yet 4 Whether the chiller has exceeded its designed lifetime replace a new compressor might be a solution II Unstable temperature If the chiller is keeping chilling or the water temperature is keep rising please check the voltage of power supply Normal voltage range 197 242V since over low voltage will make the cooling magnetic valve and bypass magnetic valve fail to alternate M No water flow or low water flow Please check below Whether there s air inside the water pump check whether the filter under the water tank is blocked whether the pump capacitor is working and the pump relay is closed 5 Maintenances Required periodic maintenance 5 1 Condenser vent hole air filter Condenser vent hole air filter should kee
5. 2 times 2 Temperature F TC K t C 5 9X T CF 32 T T 9 5 t C 32 t K 273 T C 3 Pressure unit conversion table series 1 019265 7 50062X 107 9 86923X10 1 45039x 10 Ikgf cm 9 80665 X 10 0 980665 735 559 0 967841 14 2235 4 Length linch 25 4mm 1mm 0 0394inch 5 Weight 1Lb 454g 1Kg 2 203Lb 6 Volume loz 28 4lcc 1 35 2007 2 General Information 2 1 Content Laser chiller operators manual 2 2 Productintroduction 2 2 1 Type Code Explanation Code for Client With Flow Switch Type of Pump Usage Water S Super High Lift Pump gt H High Lift Pump Chiller for Laser how Lift Pump Product family Cooling Capacity Heat exchange X0 1KW a B Back Exhausti ng S Split Type C Side Exha usti ng W Water Cooli ng NOTE ln case of no the above code means the function is not provided 2 2 2 Applications Our chillers are eguipped with digital display electronic temp Controller one key operation for varies settings and malfunction prompt function other steps will be realized by memories automatically In order to optimize and improve cooling efficiency and performance adjustable cooling system is also available for our chiller which outstandingly prolonged the life time of the compressor and enhanced temp Control Stability 2 2 3 Product Characteristics 1 Compact design convenient for installation and operation 2 All refrigerat
6. Shenzhen Sunrise Industrial Co Ltd Add No 4 the 4th Tengfeng Road the 3 Industry Zone Fenghuang Fuyong Baoan District Shenzhen China PG 1918103 Tel 86 755 3393 5303 Fax 86 755 29974586 email info dly china com URL http www dly china com LASER CHILLE Rs PH LW15 BLP 17A Notes Notes Table of Content 1 General Information l 1 1 To User 1 2 Unpacking 2 General Introduction 9 2 1 Content 2 2 Product Summary 2 3 Technical parameter 2 4 Dimensions 3 Installation and Start UQ sae 777777777 6 3 1 Safety notice 3 2 Installation location reguirements 3 3 Power 3 4 System connection 3 0 3 6 3 7 Water supplement Closed loop system Start up 4 Operation WW zdi VM d MAM 10 4 1 Temp Controller 4 2 Error codes and trouble shooting o Malintenance VES TONO v 14 5 1 Condenser vent hole filter screen 5 2 Water circuit 5 3 Water level 9 4 Periodic cleaning 6 Breakdown maintenance LS 6 1 Chiller not working 6 2 Pump not working 6 3 Pump not Pumping 6 4 Nocooling or insufficient cooling
7. ion components are international brand which can offer good and stable cooling effects Automatically cooling and heating alternating the display accuracy can reacht 0 1 C and temperature stability ist 0 3 C 0 5C 3 Use famous brand electric fan which offersbig air volume low noise and long life 4 The materials for the water cycling system are industry plastic stainless pump PVC connectors which are rust resistant 9 Eguipped with flow switch which can output protect signal 6 Equipped with high and low temperature alarm signals output it can be normal open or normal close signal as options f Use digial temperature controller which is designed by sunrise and produced by famous oem manufacturer One button operation the machine runs by memory automatically 2 7 2 Cooling system Flow Switch Ooo Evaporator o Capillary Y Coolin Drier Filter olencid Valve ASQ n nat 11111 1LLTLILTITLLITTTIT CCCI PTE MU INT po Cooling System Sketch k NO U NNN J 1 llii TITUL LLL LLL I TT J MINUET gt o IL 11 Us a C s Q gt o 60 M O o e s s a C 5d X 55 860 N O O D S T m 2 A 9 gt AU SV 0O CO N 00 16 2 3 Technical Specifications 7 Maintenance and technical support 7 1 Circuit Diagram a am 1 5mm 2 72 2 5mm 2 220V 50Hz or 60Hz PH
8. ler off the heating source at least 4inch 1 4meters such as heating tube and boiler Please install the chiller at place where drainage system is available in order to keep the installation place clean in case of any leakage occurs please don t install the chiller in erosive gas humidity dusty places or indoors with high temp Our chiller is equipped with wheel which makes it easier for installation and operation the front wheel could be locked to secure the unit Avoid voltage drops by using properly grounded power outlets wired with 14 gauges or larger diameter wire If possible be close to the power distribution panel Using an extension cord may cause low line voltage problems the voltage loss should be with 10 from the extension cord if this is inevitable The heating discharged by the fan is 1 4 times than the rated cooling capacity so the air draft and air discharge side shouldn tbe too close to wall The air discharge side should reserve at least 0 8m the installation site should ventilate well the air draft and air discharge volume of the site should be a bit large than the chiller or use air condition with larger cooling capacity than the heat discharge of the chiller to cool the installation site 3 3 Power connection Make sure the power wire rightly connected and current freguency should be match with the reguirements marked on the label which was pasted on the back of the chiller 3 4 Connection accessories P
9. or oth ree way valve inlet Laser Chiller Water inlet amp outlet installation diagram PTFE seal tape PVC connection 2 Strain the seal tape and twist around the connection 7 8 circles 3 Stretch the seal tape to its normal width then wrap the connection for 3 4 circles tighten up the seal tape before installation screw the connection gently in order to avoid PVC connection break 3 0 Water supplement Please add clean liguid in the water tank the water level should above the coil then cover the water tank 3 6 Closed loop system or bypass setting Please connect the chiller with peripheral eguipment the liguid flow direction is determined by the way of connecting liguid was pumped into chiller from inlet and pumped out from water outlet 3 7 Start up Cooling fluid Choose proper cooling fluid Notice Cooling fluid which is safe healthy environment friendly and compliance with our chiller is necessary fluid which is erosive and inflammable is not allowed Warning erosive and inflammable liquid is not allowed Warning Anti freezing liquid is necessary for operation under 8 C Warning Power off button can only turn the machine into standby 4 Operation 4 1 Temp Controller instruction Cooling System Display window Function summary Caup button press to increase setting value keep pressi ng to continuous increase Enter system menu o
10. p clean and periodically inspect in order to optimize the performance of cooling 5 2 Pure water filter Please rinse and replace the filter periodically 5 3 Liquid level Please check the water level periodically the water level should be above the coil water supplement is necessary if the water level is lower than the coil please replace the water frequently based on the actual water condition If the water flow is not normal please press the red button on the water filter to discharge the air inside the water circuit Please check whether the back water circuit is leakage and the water level is lower when there re bubbles in the soft tube and back water inlet 5 4 Clean the air filter periodically The air filter could be removed easily from both sides use gentle detergent to remove the dust clean the filter with clean water and fix the filter back after i s dry Water Water Hose 7 gt Compressed Air b Dust Filter Dust Filter View of Dust Filter cleaning 13 3 Installation and start up 3 1 Safety Notes Please ask our dealer or professional staff to install the chiller The person who installs the chiller must be certified by government recognized licensor if the chiller was not installed properly water leakage fire and wound electric shock may occur Take proper measures to prevent suffocation caused by refrigerant leakage Ifthe machine is installed indoor ventilation well could avoid of
11. r switch setting option w Down button press to decrea se setting value keep pressing to continuous decrea se CoPower switch save 8 return D In all setting interface the temp controller will save current parameters and exit setting interface for 10sec without operation Ifyou want to change the setting when alarm is showing press on off button to shut down the output 3 Press Return Power button to save and exit in any setting interface 4 Power off Press Return Power button for 3sec atany operation interface to halt system System on when power connects initial interface show for 1 5sec 2 Standby 3 System running
12. rocess pipeline There are 2 inner thread interfaces for water pipe connection and water inlet and outlet adapter is designed for connecting the accessories and working pipeline In order to keep the working site clean and safe please choose the right flexible tube and accessories based on the liguid temperature and reguired temp 4 2 6 startup option press up and down button to choose yes or no 4 3 Loadfactory default setting 4 4 Software version o Alarm prompt the LCD screen flashes when alarming on amp off every lsec default value 20C default value 0 1C Press set button to enter function option chosen option flashes press set button to enter next level setting 1 xx flashes press up and down button to adjust value 0 1 C for each press press set button to switch default value 20 C default value 0 1C 2 Function select menu to enter admin setting interface 2 1 xx flashes press up 8 down button 1min for each press default 1 min 2 2 High amp low temp Alarm flashes press set button to swich default value 40 C default value 5 C 2 3 Temp Compensation interface default value 0C 2 4 Compressor delay switch xx flashes up 8 down button 1min for each press default 1min 2 5 Function view 11 Connecting of water bypass and accessaries for water circulation water outlet stralght connect

Download Pdf Manuals

image

Related Search

Related Contents

AMR-RC SUPER DECATHLON 25%  HoMedics BPA-2000-EU blood pressure unit  EASY SALT SERIES  MANUEL D`UTILISATION Capteurs intelligents - Support  電波政策懇談会報告書(素案)(事務局)  Philips SHQ4217  4. Identificación y Solución de problemas  Manuel d`utilisation pour Torche TRACKER - All  U212460T Elliptis Linear Rev A.pmd  GBC 930-115 User's Manual  