Home

PowerScan™ D8340

image

Contents

1. Datalogic Scanning Inc 959 Terry Street Eugene Oregon 97402 USA Telephone 541 683 5700 Fax 541 345 7140 An Unpublished Work All rights reserved No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning Inc or its subsidiaries or affiliates Datalogic or Datalogic Scanning Owners of Datalogic products are hereby granted a non exclusive revocable license to reproduce and transmit this documentation for the purchaser s own internal business purposes Purchaser shall not remove or alter any proprietary notices including copyright notices contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www scanning datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contact Datalogic page DISCLAIMER Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate however Datalogic reserves the right to change any specification at any time without p
2. com PATENTS This product is covered by one or more of the following patents Design Pat AU 310201 AU 310202 CN 693980 CN735959 HK 0602013 5M001 HK 0602013 5M002 JP 1305693 KR 30 0460940 US D570 843 S USD588 596 S US Pat 5 992 740 6 305 606 B1 6 517 003 6 808 114 B1 6 997 385 B2 7 387 246 B2 5 367 151 5 449 893 5 545 889 6 098 877 6 220 514 B1 6 412 698 B2 6 607 132 B1 6 817 529 B2 6 834 805 B2 7 948 214 B2 European Pat 789 315 B1 895 175 B1 1 128 314 B1 1 128 315 B1 1 396 811 B1 1 413 971 B1 1 816 585 B1 1 942 442 B1 Additional patents pending USING POWERSCAN D8340 SERIES READERS PowerScan D8340 readers automatically scan barcodes at a distance Simply aim and pull the trigger Code scanning is performed along the scan line emitted from the reading window This line must cross the entire code The best reading angles are indicated in the figure below ANNE TAEL Fi OK has TECHNICAL FEATURES PowerScan D8340 D8340 AR PowerScan D8330 Electrical Features PowerScan D8330 AR Power Supply 4 to 30 VDC 4V 5V 30V Sleep mode Good Read LED green Reading Indicators Good Read Spot green Beeper Reading Field 97 8 cm 38 5 in 12 5 m 41 0 ft Typical performance at 20 C 68 F 40 mils 100 mils reflective on high quality barcodes PCS Datalogic Test Chart Laser Features Power man 13m Laser Safety Class Class 2 EN 60
3. 825 1 CDRH Environmental Features Working Temperature 30 C to 50 C 22 to 122 F Storage Temperature 30 C to 70 C 22 to 158 F Protection Class about 295 g 10 4 oz Cable Length 2 m 6 ft 6 in ELECTRICAL CONNECTIONS The PowerScan D8340 D8340 AR scanner can be used with CAB 468 coiled cable and 9 pin male connector for direct connection to the DATAPLUS and DLD series decoders CAB 468 1 Not connected 5 TRIGGER Q 2 3 4 5 2 SCAN 6 BEEPER LED 3 Not connected 7 VIDEO 6 9 4 GND 8 LASER ON 9 VCC 9 pin male connector A definition of the terms used to identify the pins is as follows SCAN This scanner open collector output signal is used to synchronize the decoding logic with the scanner Each transition of this signal from low to high or high to low corresponds to the start of a scan The signal is a TTL level 57 ms period square wave see the following figure Video and Scan signals GND Supply ground and signal reference TRIGGER This output is connected to GND when the trigger is pressed and is left floating when the trigger is released BEEPER LED This scanner input drives the green decoding LED and the beeper in the scanner The LED turns on when a positive current is applied to the pin The beeper sound is obtained pulsating this current at a frequency of about 2 kHz The maximum voltage that can be applied to this input is 5 VDC VID
4. CAN D8xx e tutti i suoi modelli and all its models et tous ses mod les und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate are in conformity with the requirements of the European Council Directives listed below sont conformes aux sp cifications des Directives de l Union Europ enne ci dessous den nachstehenden angef hrten Direktiven des Europ ischen Rats cumple con los requisitos de las Directivas del Consejo Europeo seg n la lista siguiente 89 336 EEC EMC Directive e 92 31 EEC 93 68 EEC emendamenti successivi and further amendments et ses successifs amendements und sp teren Ab nderungen y succesivas enmiendas Basate sulle legislazioni degli Stati membri in relazione alla compatibilit elettromagnetica ed alla sicurezza dei prodotti On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety Bas e sur la l gislation des Etats membres relative la compatibilit lectromagn tique et la s curit des produits ber die Ann herung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Vertr glichkeit und Produktsicherheit entsprechen Basado en la aproximaci n de las leyes de los Pa ses Miembros respecto a la compatibilidad electromagn tica y las Medidas de seguridad relativas al producto Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti This declaration is
5. Ce manuel est aussi disponible en version frangaise Cliquez sur www scanning datalogic com En Internet estan disponibles las versiones actualizadas de los drivers y documentaci n de este producto Tambi n esta disponible la versi n en espanol de este manual Direcci n Internet www scanning datalogic com CONNECTIONS CONNECTING THE CABLE A Rubber gasket B Plastic boot C Cable spacer D Cover E Strain relief Slip the cover over the cable Push the plastic boot into the rubber gasket Take care that the tab on the plastic boot is aligned with the notch in the rubber gasket i Pos Push the plastic boot and gasket PX into the handle Ensure that the 9 Front marking on the plastic boot is facing out with the arrow pointing towards the front of the scanner Insert the cable into the socket of the plastic boot Insert the cable spacer into the cable wire and slide it towards the handle Push the cover along the cable towards the reader and hook it over the yellow tooth Insert the strain relief into the cover and tighten the screw to fix the whole assembly to the reader handle COMPLIANCE LASER SAFETY COMPLIANCE The laser scanner conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN60825 1 at the date of manufacture The laser light is visible to the human eye and is emitted from the output window 1 4 Laser warning and classification label 2 CAU
6. EO This open collector scanner output is electrically identical to the barcode It supplies a series of pulses the length of which are proportional to the width of the elements within the barcode read A low output level corresponds to a bar The frequency of the pulses depends on the density of the code the distance from code and the programmed output scan frequency see the following figure Video and Scan signals LASER ON A positive voltage between 4 75 and 5 VDC is applied to this input by the decoder when the decoding logic senses the trigger is pressed this causes the laser to start scanning and the red LED to turn on VCC This input must be connected to the positive pin of the supply voltage 4 75 14 VDC When the LASER ON pin is positive all the current necessary to power the scanner flows through VCC WU TO LS Video and Scan Signals DATALOGIC SCANNING LIMITED FACTORY WARRANTY Warranty Coverage Datalogic warranties this product against defects in workmanship and materials for a period of 3 years from the date of shipment provided that the product is operated under normal and proper conditions Datalogic Scanning Datalogic hardware products are warranted against defects in material and workmanship under normal and proper use The liability of Datalogic under this warranty is limited to furnishing the labor and parts necessary to remedy any defect covered by this warranty and restore the product to its norm
7. TION 2 Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous visible laser light The laser scanner utilizes a low power laser diode Although staring directly at the laser beam momentarily causes no known biological damage avoid staring at the beam as one would with any very strong light source such as the sun Avoid that the laser beam hits the eye of an observer even through reflective surfaces such as mirrors etc The following information is shown on the laser scanner device class label DO NOT STARE INTO BEAM CAUTION CLASS 2 LASER LIGHT WHEN OPEN AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE This product complies with 21 CFR Subchapter J ITALIANO LUCE LASER NON FISSARE IL RAGGIO APPARECCHIO LASER DI CLASSE 2 FRAN AIS RAYON LASER EVITER DE REGARDER LE RAYON APPAREIL LASER DE CLASSE 2 DEUTSCH LASERSTRAHLUNG NICHT IN DEN STRAHL BLICKEN PRODUKT DER LASERKLASSE 2 ESPA OL RAYO L SER NO MIRAR FIJO EL RAYO APARATO L SERDE CLASE 2 LED CLASS Class 1 LED product This product conforms to EN60825 1 2001 CE COMPLIANCE Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authorit
8. al operating condition Repair or replacement of product during the warranty does not extend the original warranty term Products are sold on the basis of specifications applicable at the time of manufacture and Datalogic has no obligation to modify or update products once sold If Datalogic determines that a product has defects in material or workmanship Datalogic Shall at its sole option repair or replace the product without additional charge for parts and labor or credit or refund the defective products duly returned to Datalogic To per form repairs Datalogic may use new or reconditioned parts components subassemblies or products that have been tested as meeting applicable specifications for equivalent new material and products Customer will allow Datalogic to scrap all parts removed from the repaired product The warranty period shall extend from the date of shipment from Data logic for the duration published by Datalogic for the product at the time of purchase War ranty period Datalogic warrants repaired hardware devices against defects in workmanship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the orig inal warranty period whichever is longer Datalogic does not guarantee and it is not responsible for the maintenance of damage to or loss of configurations data and appli cations on the repaired units and at its sole
9. based upon compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf da das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con las siguientes normas EN 55022 Class A ITE August 1994 LIMITS AND METHODS OF MEASUREMENTS OF RADIO AMENDMENT A1 CLASS A ITE October 2000 DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT EN 61000 6 2 October 2001 ELECTROMAGNETIC COMPATIBILITY EMC PART 6 2 GENERIC STANDARDS IMMUNITY FOR INDUSTRIAL ENVIRONMENTS March 1st 2007 DATALOGIC PowerScan D8340 READERS QUICK REFERENCE GUIDE Ju 820035814 Rev E ly 2011 UPDATES AND LANGUAGE AVAILABILITY UK US The latest drivers and documentation updates for this product are available on the Internet Log on to www scanning datalogic com Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto Questo manuale disponibile anche nella versione italiana Collegarsi a www scanning datalogic com D Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation f r dieses Produkt Die deutschsprachige Version dieses Handbuches ist auch verf gbar Adresse www scanning datalogic com F Les versions mises a jour de drivers et documentation de ce produit sont disponibles sur Internet
10. discretion can return the units in the factory default configuration or with any software or firmware update available at the time of the repair other than the firmware or software installed during the manufacture of the prod uct Customer accepts responsibility to maintain a back up copy of its software and data Warranty Claims Process In order to obtain service under the Factory Warranty Customer must notify Datalogic of the claimed defect before the expiration of the applicable Warranty period and obtain from Datalogic a return authorization number RMA for return of the product to a desig nated Datalogic service center If Datalogic determines Customer s claim is valid Datalogic will repair or replace product without additional charge for parts and labor Customer shall be responsible for packaging and shipping the product to the designated Datalogic ser vice center with shipping charges prepaid Datalogic shall pay for the return of the prod uct to Customer if the shipment is to a location within the country in which the Datalogic service center is located Customer shall be responsible for paying all shipping charges duties taxes and any other charges for products returned to any other locations Failure to follow the applicable RMA policy may result in a processing fee Customer shall be responsible for return shipment expenses for products which Datalogic at its sole discre tion determines are not defective or eligible for warrant
11. rior notice Datalogic is a registered trademark of Datalogic S p A in many countries and the Datalogic logo is a trademark of Datalogic S p A all licensed to Datalogic Scanning Inc All other trademarks and trade names referred to herein are property of their respective owners SERVICE AND SUPPORT Datalogic provides several services as well as technical support through its website Log on to www scanning datalogic com and click on the links indicated for further information including PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software amp Utilities including Datalogic Aladdin a multi platform utility program that allows device configuration using a PC It provides RS 232 interface configuration as well as configuration barcode printing SERVICE amp SUPPORT Technical Support Product documentation and programming guides and Technical Support Department in the world Service Programs Warranty Extensions and Maintenance Agreements Repair Services Flat Rate Repairs and Return Material Authorization RMA Repairs Downloads Manuals amp Documentation Data Sheets Product Catalogues etc CONTACT US Information Request Form and Sales amp Service Network Datalogic Scanning Inc 959 Terry Street 07 Eugene OR 97402 USA dichiara che declares that the d clare que le bescheinigt da das Ger t declare que el POWERS
12. stomer may not assign or otherwise transfer its rights or obligations under this warranty except to a purchaser or transferee of product No attempted assignment or transfer in vio lation of this provision shall be valid or binding upon Datalogic DATALOGIC S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED ORAL OR WRITTEN STATUTORY OR OTHERWISE INCLUDING WITHOUT LIMITA TION ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PUR POSE OR NONINFRINGEMENT DATALOGIC SHALL NOT BE LIABLE FOR ANY DAMAGES SUSTAINED BY CUSTOMER ARISING FROM DELAYS IN THE REPLACEMENT OR REPAIR OF PRODUCTS UNDER THE ABOVE THE REMEDY SET FORTH IN THIS WARRANTY STATEMENT IS THE CUSTOMER S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS OR ANY INCIDENTAL CONSEQUENTIAL IN DIRECT SPECIAL OR CON TINGENT DAMAGES REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic Datalogic shall assume risk of loss or damage for product in Datalogic s possession In the absence of specific written instructions for the return of product to Customer Datalogic will select the carrier but Datalogic shall not thereby assume any liability in connection with the return shipment
13. y repair Warranty Exclusions The Datalogic Factory Warranty shall not apply to i any product which has been damaged modified altered repaired or upgraded by other than Datalogic service personnel or its authorized representatives ii any claimed defect failure or damage which Datalogic determines was caused by faulty operations improper use abuse misuse wear and tear negligence improper storage or use of parts or accessories not approved or supplied by Datalogic iii any claimed defect or damage caused by the use of product with any other instrument equipment or apparatus iv any claimed defect or damage caused by the failure to provide proper maintenance including but not limited to cleaning the upper window in accordance with product manual v any defect or damage caused by natural or man made disaster such as but not limited to fire water damage floods other natural disasters vandalism or abusive events that would cause internal and external component damage or destruction of the whole unit consumable items vi any damage or malfunctioning caused by non restoring action as for example firmware or software upgrades software or hardware reconfigurations etc vii the replacement of upper window cartridge due to scratching stains or other degradation and or viii any consumable or equivalent e g cables power supply batteries keypads touch screen triggers etc No Assignment Cu
14. y to use the equipment This device complies with PART 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference which may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense POWER SUPPLY This device is intended to be connected to a UL Listed CSA Certified computer which supplies power directly to the reader or else be supplied by a UL Listed CSA Certified Power Unit marked Class 2 or LPS power source rated 4 30 V minimum 420 mA which supplies power directly to the reader via the power connector of the cable WEEE COMPLIANCE For information about the disposal of Waste Electrical and Electronic Equipment WEEE please refer to the website at www scanning datalogic

Download Pdf Manuals

image

Related Search

Related Contents

Mod. 300 - MAXILIFT and COBRA Truck Cranes. North Eastern  INST.  Samsung ME711K/FAL Manuel de l'utilisateur  Black Box Portable Media Storage QCE-GK User's Manual  Belkin 24-Port CAT 5e Patch Panel  取扱説明書 - 1.22 MB  Rundbiegemaschine 8266 - Välkommen till Nossebro Mekaniska AB!    Haier FCD-JTHA40-III(ET) User's Manual  Cómo identificar las piezas de la aspiradora  

Copyright © All rights reserved.