1. User Manual for NG D9300 Series Digital Control Color Monitor 2001 Aristocrat Technologies Inc All Rights Reserved ARISTOCRAT D9300 NG SET UP Setting up the Wells Gardner D9300 monitor is easy All you have to do is make a few simple connections and adjustments The procedure is as follows START UP The monitor starts automatically when you connect to the power source SINGLE CABLE CONNECTION The monitor connects automatically as it is inserted into the cabinet Use the standard extension cable 569106 to operate the monitor outside the cabinet 12 PIN DRAWER PLUG BEAU PLUG PIN NO DESCRIP TION PIN NO DESCRIPTION RED VIDEO Touchscreen RX GREEN Video Touchscreen GND Video Ground V SYNC Mains GND H SYNC CO 7 MT Y O BLUE Video 9 Touchscreen TX 10 Y O tt 10 11 2 I AMP 211759 1 Pin Locations Connection View 2001 Aristocrat Technologies Inc Page 2 of 4 e ARISTOCRAT D9300 SPECIFICATIONS Picture Tube e Size 18V 17 inch diagonal e Dot Pitch 0 25mm Signal Input e Video Input Analog Positive Signal 0 7V p p e Horizontal Sync TTL Level Positive or Negative Pulse e Scanning 28 KHz 70KHz e Vertical Inout TTL Level Positive or Negative pulse e Scanning 40 160Hz Power Supply e Power Input 120 240 VAC 50 60Hz e Fuse Rating 250V 3 15A e Power Consumption Normal less than 130W On Screen Display OSD Control OPERATING TEMPERATU
2. RE 0 C 55 C OPERATING HUMIDITY 10 90 Non condensing NET WEIGHT 17kg 37lbs Standard frame TECHNICAL FEATURES Microprocessor control with OSD On Screen Display menu Microprocessor recognizes the input computer signal and the signal output from the customer control board connected to the main board by a ribbon cable Universal AC Input Voltage Power supply operates on 120 240 VAC at 60 50Hz for use all over the world Protection Circuit for over current When an over current condition occurs in the circuit the protection circuit operates in order to prevent the components from electrical shock or other risks Override function A NO SIGNAL message is displayed on the screen if no signal is present at the signal input cable while the monitor is powered on Control panel If you require different display characteristics other than the factory mode presets of size position color settings use the control panel to program it to your requirements in each resolution mode These adjusted settings remain in memory even if you change resolution mode or turn off the monitor PC BUS CONTROL The monitor is designed with 2C BUS control for simplifying the circuitry The number of total components is less than 610 pieces 2001 Aristocrat Technologies Inc Page 3 of 4 ARISTOCRAT D9300 NG SAFETY PRECAUTIONS WARNING Persons not familiar with the necessary safety precautions on this unit should never attempt to service it
3. The following safety precautions are necessary during servicing 1 some parts such as a picture tube in this unit have special safety related characteristics for X RAY RADIATION protection For continued safety parts replacement should be undertaken referring to article 1 2 and 1 5 Many electrical mechanical parts in this unit have special safety related characteristics for protection against shock hazard and others These characteristics are often unnoticed by visual inspection and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage wattage etc Replacement parts which have these special characteristics are identified in the service manual and supplements by shading on the schematic diagram and in the parts list Before replacing any of these components read the parts list in the service manual very carefully When replacing the chassis in the cabinet always be certain that all the protective devices are properly installed such as insulating covers strain relief etc Thoroughly inspect the inside of the cabinet to see that no stray parts or tools have been left inside Before returning the monitor to EX stock always perform an AC leakage current check on the exposed metallic parts such as terminal screw heads metal overlays control shafts etc a To insure the set is safe to operate without danger of electrical shock plug the AC line cord di
4. rectly into a 120V AC outlet do not use a line isolation transformer during this check i Use an AC voltmeter having 5000 ohms per volt or more sensitivity in the following manner ii Connect a 15000 10w resistor parallel with a 0 15UF capacitor b Voltage measured must not exceed 0 3V RMS This corresponds to 0 2mA AC i Any value exceeding this limit constitutes a potential shock hazard and must be corrected immediately c Reverse the AC plug in the AC outlet and repeat the AC voltage measurements for each exposed metallic part 2001 Aristocrat Technologies Inc Page 4 of 4

Download Pdf Manuals

image

Related Search

Related Contents

Installation Manual  EPOXY BOND R  Williams/Kilburn House Manchester Customer Service Manual  Mémoire 2011 - Institut de médiation et d`arbitrage du Québec    Baixar Arquivo Pdf  ACTIVATEUR S    Garmin GPSMAP 76 Hand Held Marine GPS  

Copyright © All rights reserved.
Failed to retrieve file