1. R schiage Wyreless Access Addendum INSTALLING CONFIGURING amp OPERATING PANEL INTERFACE MODULE RS485 Apollo Version PIM OTD 485 APL The most current version of this document is available for download at http www irsupport net HD schiage Wyreless Access IR Security amp Safety 575 Birch St 866 322 1237 866 322 1233 fax P N M053 017 A SD schiage Wyreless Access 575 Birch St Forestville Ct 06010 866 322 1237 866 322 1233 Fax World Wide Web http www irsupport net Copyright 2003 2004 Ingersoll Rand all rights reserved No part of this document can be reproduced transmitted or transcribed in any form by electrical mechanical optical manual or otherwise without the prior written consent of Ingersoll Rand Ingersoll Rand reserves the right to alter or revise the content of this document as needed to support future product revisions without obligation to notify any persons of specific changes The use of trademarks trade names or other product identification is solely for reference purposes All other product brand names are trademarks or registered trademarks of their respective holders Ingersoll Rand believes the information in this document to be accurate and reliable Ingersoll Rand does not guarantee results from the use of this information Ingersoll Rand assumes no responsibility obligation or liability for the information presented in this document
2. s CR7 amp CR10 start to flash the SA SB switch can be released This places the PIM OTD 485 APL in the CDT communication mode If the CDT is shut down and restarted the PIM OTD 485 APL must be reset as indicated above to return to the CDT communication mode 2 1 1 PIM OTD 485 APL Configuration Once the CDT shows that the PIM OTD 485 APL is connected the Addresses tab on the CDT s PIM panel is used to configure the PIM OTD 485 APL s emulation addresses There are three fields on the Addresses tab Unique Addr Lo amp Addr Hi The Unique field shows the PIM OTD 485 APL unique address and should never be changed without instructions from Schlage Technical Support The Addr Lo indicates the lowest reader address that the PIM OTD 485 APL will emulate and Addr Hi indicates the highest Table 2 1 shows the allowable range of values for the Addr Lo amp Addr Hi fields on the CDT Addresses tab PIM Model Addr Lo Addr Hi PIM OTD 485 APL Table 2 1 CDT Addr Lo amp Addr Hi Fields Range of Values After setting the Addr Lo amp Addr Hi fields to the desired values click the Set button to send these values to the PIM OTD 485 APL Rules for setting Addr Lo amp Addr Hi Addr Hi must always be equal to or greater than Addr Lo For multiple PIM OTD 485 APLs on the same communications port there cannot be any address overlap in other words on the same communications port there can be only one PIM OTD 485 APL emulating a specific A
3. MAXIMUM ACCESS CONTROL PANEL MODEL ENCLOSURE eae LOCATION INTERFACE DESCRIPTION PIM PIMOTD 48S APL 485 APL plastic indoor RSIS ANT REMOTE plastic aa indoor Optional remote omni outdoor directional antenna ANT 6DB FLAT plastic ali indoor Optional remote directional outdoor panel antenna 6 dB gain ANT 6DB YAGI A TER EE Ta indoor Optional remote directional yagi outdoor antenna 6 dB gain Table 1 2 PIM OTD 485 APL Sales Model Table IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 6 of 13 a Wyreless Access 2 Installing the PIM OTD 485 APL 2 1 Configuring the PIM OTD 485 APL to Emulate Apollo Readers The Schlage Configuration amp Demonstration Tool CDT version 1 4 or higher must be used to configure each PIM OTD 485 APL to emulate the desired number and address of ARK ASR or AI Readers The PIM OTD 485 APL must be connected to the PC running the CDT using a serial connection either RS485 or RS232 NOTE When using an RS232 connection any RS485 connection must be disconnected for the CDT to operate properly Remember to re connect the RS 485 when done configuring Once the PIM OTD 485 APL is powered and connected to the PC and the CDT is running press and hold either the SA or SB switch on the PIM OTD 485 APL while pressing and releasing the Reset switch on the PIM OTD 485 APL Once the PIM OTD 485 APL LED
4. 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 13 of 13
5. 9 of 13 a Wyreless Access After setting the Panel field to the desired value for the WAPM being linked click the Start button to place the PIM OTD 485 APL into the link mode Power up or reset the WAPM to initialize the linking process between the PIM OTD 485 APL and the WAPM NOTE For proper operation the Panel field must only be set to the range of values for which the PIM OTD 485 APL has been configured to emulate Section 2 1 The Stop button can be used to abort the PIM OTD 485 APL link mode 2 4 PIM OTD 485 APL Alarms Each WAPM linked to a PIM OTD 485 APL can report five different types of alarms low battery reader tamper loss of RF communications lock motor stall and PIM tamper The PIM OTD 485 APL reports these alarms using specific APACS alarm addresses as shown in Table 2 7 Low Battery uerit TGE Table 2 7 Alarms Generated by a PIM OTD 485 APL 2 5 What Happens if the PIM OTD 485 APL Loses DC Power All of the configuration and linking information is stored in non volatile memory in the PIM OTD 485 APL Therefore if PIM OTD 485 APL DC power is lost or cycled upon restoring DC power the PIM will continue operation with the same configuration and linking information There is no need to re configure or re link 2 6 Using the PIM OTD 485 APL Reset Switch The Reset Switch S3 is used if the PIM OTD 485 APL does not seem to be working properly Pressing the Reset Switch has the same effect as cycling DC pow
6. addresses each PIM OTD 485 APL will emulate NOTE This manual is to be used in addition to the PIM Installation Manual M053 001 xxx and the Wyreless Access System Configuring and Operating Manual M053 007 xxx There are five steps to installing a PIM OTD 485 APL 1 Using the PIM Installation manual M053 001 xxx determine the optimum PIM OTD 485 APL mounting location and permanently mount the PIM OTD 485 APL in that location 2 Using the Apollo Installation Guidelines 100718 A and AAN 100 Access Alarm Network Controller Installation 01276 D manuals mount and install the AAN 100 and connect it to the PC that will be running the Apollo Access and Alarm Management Program APACS 3 Using this manual configure amp connect the PIM OTD 485 APL to the AAN 100 section 2 2 page 8 4 Using the Apollo Access and Alarm Management Program User s Manual 101505 A configure the software to work with the PIM OTD 485 APL 5 Using this manual link the PIM OTD 485 APL to all the WAPMs it will control section 2 3 page 9 IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 5 of 13 Table 1 1 and Table 1 2 show the PIM OTD 485 APL sales models and their major specifications Sales pIM OTD 485 APIL Closed Enclosure Opened Enclosure internal c Antenna or optional Table 1 1 PIM OTD 485 APL Enclosure
7. at the access control point may be required Regardless of which WPIM or WAPM module is used the communication link between the WPIM and WAPM is always RF This manual describes the installation and operation of a Panel Interface Module RS485 Apollo PIM OTD 485 APL a WPIM IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 4 of 13 SD schiage Wyreless Access 1 2 Panel Interface Module RS485 A pollo PIM OTD 485 APL The Panel Interface Module RS485 Apollo PIM OTD 485 APL is a product in Schlage s Wyreless Panel Interface Module WPIM category The PIM OTD 485 APL is the wireless interface to an Apollo AAN 100 Access Alarm Network Controller Figure 1 2 j r c Apollo AAN 32 a Wyreless 100 Access Access a RF Communication Point vee nO Communication xx AP Communication Point Alarm Module Controller Access Control Panel Location Access Point Location from to 16 Figure 1 2 PIM OTD 485 APL Block Diagram Each PIM OTD 485 APL is connected via a 2 wire polled RS 485 interface to an AAN 100 Each PIM OTD 485 APL can emulate up to 16 Apollo ASR ARK or AI readers therefore a PIM OTD 485 APL can control from 1 to 16 WAPM s The Schlage Configuration amp Demonstration Tool CDT is used to determine what and how many RS 485 polling
8. IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 2 of 13 SD schiage Wyreless Access INSTALLATION amp OPERATING INSTRUCTIONS TABLE OF CONTENTS 1 Wyreless Access System VV AS cctectstsscsseces tee sstenstsseieasiccossececentsassesostecccenteessecostesevsebescsesostececenbeeusecosseseusabeeyee 4 MHOC NW E E E E A E cack A EN A T E E E E A E E 4 1 2 Panel Interface Module RS485 Apollo PIM OTD 485 APL cccccccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 5 2 Tnstalline the PIVI O TD 485 24 PU sicssvascssccsccccipevissccsisasanesscsnceccceecanasedevanseuesenssevannceececeeusdeseussaessensvesessasseosanatesete 7 2 1 Configuring the PIM OTD 485 APL to Emulate Apollo Readers ccccccccccccccccccccceceeeeeeeeeeeeeeeeeeeeeeeeees 7 2 2 Connecting the PIM OTD 485 APL to the AAN LOQ ccccccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee es 8 2 3 Linking the PIM OTD 485 APL to WAPMS 0 ccc ccccccccccceceeeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE EEE EH 9 24 PIM OTD 4 5 APL Alarms te sates cece ictus dectoa e a aa E aai aiei 10 2 5 What Happens if the PIM OTD 485 APL Loses DC Powetr ccccccccccccccccccccccceeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeeees 10 2 6 Using the PIM OTD 485 APL Reset Switch nnnnnennnenenneeeennseneeesennnssnseersreerereresrsesrrrrrrrerrrrrrrrrrreree
9. RK ASR or AI reader address The ARK ASR or AI reader addresses emulated by a PIM OTD 485 APL must be consecutive 2 1 2 WAPM Configuration when using Apollo AI Magnetic Readers The CDT is used to configure a Wyreless Access Point Module WRI or WUSI to work with an Apollo AI Magnetic readers The Apollo Access Control system uses several different magnetic card formats Format M1 is the only format implemented to date Once the CDT shows that the PIM OTD 485 APL is connected and after the desired WAPM has been linked to the PIM OTD 485 APL the WAPM Configuration tab on the CDT 1s used to select the Apollo M1 magnetic card format Set the Card Conversion field on the Configuration tab to Apollo M1 and click the Set button wait for the Status to return to none NOTE If using an Apollo ARK or ASR proximity reader then the Card Conversion field must be set to none IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 7 of 13 SD schiage Wyreless Access 2 2 Connecting the PIM OTD 485 APL to the AAN 100 Note The following connection information assumes that the AAN 100 has an ASM 48 RS 485 device port module installed in the communication port to be used 2 2 1 PIM OTD 485 APL using an Original PIM PCB AAN 100 Communication Ports 3 6 PIM OTD 485 APL J6 R amp T Table 2 2 RS485 Connection O
10. e requirements for mobile transmitting devices this transmitter should only be used or installed at locations where there is normally at least a 20 cm separation between the antenna and all persons Do not co locate and operate in conjunction with any other antenna or transmitter Use only the Battery Pack specified in this instruction manual Do not subject Battery Pack to fire or high temperatures Do not attempt to recharge short out or disassemble Battery Pack Follow local regulations for alkaline battery disposal Immediately remove the batteries and discontinue use if the product is impacted after which the interior is exposed or the product emits a strange smell heat or smoke Changes or modifications not expressly approved by Schlage could void the users authority to operate the equipment IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax http www irsupport net Page 12 of 13 SD schiage Wyreless Access 5 Revision History X001 07 09 02 preliminary in house release for comments 08 07 02 added paragraph about putting PIM in CDT mode released for publication 002 08 08 02 added paragraph about restarting CDT released for publication 003 11 27 02 changed sales model numbers added dynamic channel switching table added 4 wire RS485 section released for publication IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860
11. ens 10 w aen SC AE a a se sdu ee nea ca cecuee le awced ee sdeedets se enucececwaueteonaueccedvauees 11 4 FCC Compliance VV NS oso goose neseececcsnacentevnac ennnen AN e EEEN Er RESEN NETTE EAEEREN EERE onidan 12 AE PCC 60 00 0 121106 segnen A AA ee ee ee 12 A W a a aa ea bw henna ote ona 12 S Revision FANS OEY aona E E 13 IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 3 of 13 a Wyreless Access 1 Wyreless Access System WAS 1 1 Overview Every access control system that uses Wyreless Access contains two different types of modules Figure 1 1 e at least one Wyreless Panel Interface Module WPIM and e atleast one Wyreless Access Point Module WAPM a a l Z Wyreless Wyreless Access Panel Access Control ace Interface RF Communication Point a o Panel Module Module WPIM WAPM Access Control Panel Location Access Point Location Figure 1 1 Wyreless Access System Block Diagram The WPIM is wired to the access control panel and ideally is installed very close to the access control panel The WPIMs installation location is determined by the location of the WAPMs with which it will communicate using RF The WAPM is installed at the access point where access will be controlled and or monitored Depending on the application and which WAPM is used some wiring
12. er to the PIM OTD 485 APL IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 10 of 13 a Wyreless Access 3 Contacting Schlage For questions regarding Wyreless Access customerservice recognition source com sales recognition source com techsupport recognition source com www recognition source com 630 762 4450 630 762 4444 fax IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 11 of 13 a Wyreless Access 4 FCC Compliance amp Warnings 4 1 FCC Compliance This device has been authorized by the FCC Rules and Industry Canada This device complies with the limits for a Class B digital device and a Class B intentional radiator pursuant to Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The Wyreless Access System Component must be installed by qualified professionals or contractors in accordance with FCC part 15 203 Antenna Requirements Do not use any antenna other than the one provided with the unit 4 2 Warnings P N M053 017 A RF Exposure To comply with FCC RF exposur
13. riginal PIM PCB amp AAN 100 2 2 2 PIM OTD 485 APL using a RS485 PIM PCB configured for 2 wire communication AAN 100 Communication Ports 3 6 PIM OTD 485 APL J7 R amp T f TA amp RA TB amp RB Table 2 3 RS485 Connection RS485 PIM PCB amp AAN 100 2 2 3 PIM OTD 485 APL using a RS485 PIM PCB configured for 4 wire communication AAN 100 oom Ports 3 6 PIM OTD 485 APL J7 Table 2 4 RS485 Connection RS485 PIM PCB amp AAN 100 IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page 8 of 13 SD schiage Wyreless Access 2 3 Linking the PIM OTD 485 APL to WAPMs 2 3 1 How to Set an RF Channel Group The PIM OTD 485 APL uses dynamic channel switching to improve RF reliability Dynamic channel switching uses RF channel groups consisting of 3 RF channels There are 5 RF channel groups DIP switch SW7 on the PIM selects which of the 5 RF channel groups will be used Table 2 5 shows how to set SW7 to select the desired RF channel group RF Channel Switch 1 Switch 2 Switch 3 Switch 4 i 6 11 e e up e e up down a ara wn H aoun f ue H up Table 2 5 DIP Switch Setting to Select the RF Channel Group NOTE The first two switch settings select channel group 1 2 3 2 Linking WAPM s using the Configuration amp Demonstration Tool CDT The Schlage Configuration amp Demonstra
14. tion Tool CDT version 1 4 or higher must be used to link WAPM s to a PIM OTD 485 APL The PIM OTD 485 APL must be connected to the PC running the CDT using a serial connection either RS485 or RS232 NOTE When using an RS232 connection any RS485 connection must be disconnected for the CDT to operate properly Remember to re connect the RS 485 when done configuring Once the PIM OTD 485 APL is powered and connected to the PC and the CDT is running press and hold either the SA or SB switch on the PIM OTD 485 APL while pressing and releasing the Reset switch on the PIM OTD 485 APL Once the PIM OTD 485 APL LED s CR7 amp CR10 start to flash the SA SB switch can be released This places the PIM OTD 485 APL in the CDT communication mode If the CDT is shut down and restarted the PIM OTD 485 APL must be reset as indicated above to return to the CDT communication mode Once the PIM OTD 485 APL is connected to the PC and the CDT is running the Link tab on the CDT s PIM panel is used to control the PIM OTD 485 APL s Link Mode The Panel field must be set to indicate which WAPM is to be linked Table 2 6 shows the allowable range of values for the Panel field on the CDT Link tab PIM Model Panel Field PIM OTD 485 A PL Table 2 6 CDT Panel Field Range of Values for PIM Models IR Security amp Safety 575 Birch St Forestville Connecticut 06010 860 584 9158 860 584 2136 fax P N M053 017 A http www irsupport net Page
Download Pdf Manuals
Related Search
Related Contents
Manual de usuario Manual. - Liliana Bedienungsanleitung Herzlichen Glückwunsch Guia do Usuário DBC-Pro Driver Body Camera User Manual ABV 取扱説明書 - 山田照明 Sennheiser 92828 ear plug Motorola Moto G - Charity Mobile Philips I928 16GB Black manual de instruções trado tipo caneco modelos: tc-2 Copyright © All rights reserved.