Home
Owner`s Manual - Backyard Pool Superstore
Contents
1. of the amp XQ product Some states do not allow a limitation of damages so the foregoing limitation may not apply to you This warranty gives you specific legal amp rights and you may have other rights that vary from state to state ax INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES THIS WARRANTY IS IN LIEU OF ALL OTHER oe EXPRESS OR IMPLIED WARRANTIES ALL IMPLIED WARRANTIES INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF g FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY AND SHALL BE amp OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE amp This warranty service is available by either a returning the product to the dealer from whom the unit was purchased or b mailing postage prepaid 6 to the nearest authorized service center listed Please be sure to wrap the product securely when mailing to avoid shipping damage This warranty is a lt made by Intermatic Incorporated After Sales Service 7777 Winn Rd Spring Grove IL 60081 9698 815 675 7000 http Avww intermatic com Because of our commitment to continuing research and improvements Intermatic Incorporated reserves the right to make changes without notice in the specitications and material contained herein and shall not be responsible tor any damages direct or consequential caused by reliance on the material presented INTERMATIC INCORPORATED
2. SPRING GROVE IL 60081 9698 158PB12524 http 7 www intermatic com INSTALLATION OPERATION amp SERVICE MANUAL NTERMATIC Ad PBSOOE SERIES TIME CONTROLS 24 Hr Electronic Timer Replacement Upgrade Kits Model PB313EK Clock Supply Voltage 120 V 50 60 HZ Model PB314EK Clock Supply Voltage 240 V 50 60 HZ a GENERAL INFORMATION The PB300EK Series Electronic Timers are made to fit and replace most PB series Intermatic and certain other brand mechanical or electronic timers The connected load however must not exceed the rating of this vg timer The timer is completely enclosed and a replaceable lithium battery will hold up memory for up to three years The kit contains all the necessary hardware for a SELECT es ON AUTO OFF o speedy repair or exchange SPECIFICATIONS Intermatic Rating MYLAR INSULATOR 16A Resistive 8A FLA P 2 362 O EEEE Contact Configuration i 2 125 S74 ee 079 BEFORE INSTALLATION Single Pole Double Pole l m f fo Power Consumption BV A a YINTERMaTIC yO Battery Type N l ii 2 362 2 125 CR2032 1 5V Lithium oon ON AO OF mo NC Battery Life Q A ONO C O 3 Years Minimum T No of Programming Periods T A O 8 On 8 Off ai 1 102 INDEPENDENT ni CLOCK SUPPLY Mimon tatere 250 MALE QUICK CONNECT 1 minute
3. TERMINALS CAUTION e Prior to installation disconnect electricity at main panel e Make sure the clock supply voltage of the timer slated for replacement is the same as this timer e Make sure the intended load is within the capacity of this timer see specifications above 1 Both the old and the new timers have two sets of terminals LOAD and CLOCK SUPPLY Identify and mark the leads connected to these terminals 2A Old Timer with four 1 4 inch tabs Remove female terminals from tabs and remove timer Install new timer using the screws and nuts supplied Reconnect the two clock supply leads to CLOCK SUPPLY terminals and either one of the load leads to terminal C and the other load lead to N O normally open terminal 2B Old Timer with two CLOCK SUPPLY LEADS and two 1 4 inch LOAD tabs Disconnect leads at twist on wire connectors and remove female terminals from tabs Remove timer Install new timer using the screws and nuts sup plied Connect the stripped ends of either leads supplied to either wire nutted junctions Connect either one of the load leads to terminal C and the other load lead to N O normally open terminal 2C For other than Intermatic made timers timers with 5 tabs and or permanently attached leads identify first each lead or tab then follow 2A or 2B above and corresponding markings on back of new timer
4. http waterheatertimer org Intermatic timers and manuals html PB SETTING OPERATING INSTRUCTIONS Programming Instructions To Set or Change the Time of Day To clear entire memory press key Hold down the CLOCK key while pressing either the HOUR or MINUTE keys Continue pressing until the desired number is shown Then simply lift finger off the CLOCK key to set To Set Program ON OFF times Press TIMER key once to enter into program mode Display will show 1 ON Press the HOUR key and then the MINUTE key to select the desired first ON time Press TIMER key once Display will show 1 OFF Repeat previous step to select the desired first OFF time Repeat the entire sequence to complete up to eight total ON OFF times as desired When program ming is done press the CLOCK key then the SELECT key repeatedly until the indicator bar is above the word AUTO To Review Program Press TIMER key repeatedly When done press CLOCK key to return to the time of day To Cancel Change Part of the Program Press TIMER key repeatedly until the particular ON or OFF time appears Set new ON of OFF time See To Set Programs To Override the Automatic Operation one time Press OVR KEY TROUBLESHOOTING Symptom Possible Cause s Y ANTERMATIC Display Reset port to cancel all prior settings ON AUTO OFF Select Key Indicator LED ON when connected to power source and contacts are closed Func
5. tion Keys NOTE Timer will resume automatic operation with the next opposite setpoint To Override Automatic Operation Permanently Press SELECT key to move indicator bar to the desired ON or OFF position Note Timer will not resume automatic operation until indicator bar is repositioned above the word AUTO Corrective Action Blank Display Discharged battery Defective timer ee ee Replace battery ee eee er ee Replace timer Timer will not respond to programming Memory is full bps ik wa hie kbs Press to clear memory Timer will not function as programmed SELECT mode Timer is ON at all times Timer is in the wrong Timer is in ON mode Defective timer dae Pane ae Press SELECT key and move indicator bar over to AUTO ite bse EEE See above ee ee re Replace timer ONE YEAR LIMITED WARRANTY BS If within the warranty period specified this product fails due to a defect in material or workmanship Intermatic Incorporated will repair or replace os SS T at its sole option the unit free of charge This warranty applies only to the original purchaser and is not transferable This warranty does not apply amp to a damage caused by accident abuse mishandling dropping acts of God or any negligent use b units which have been subject to unautho Q Ko oa repair opened taken apart or otherwise modified c units not used in accordance with instructions d damages exceeding the cost
Download Pdf Manuals
Related Search
Related Contents
Télécharger - PORTAIL PBF CONEQ™ C1 通信ツール Communication Tool Getting Started - Sprint Support ー 踏台(上わく付き専用脚立) ー 取扱説明書 Ditec Traffic C EVGA 01G-P4-2753-KR NVIDIA GeForce GTX 750 1GB graphics card 取扱説明書 カタログ用抜粋版 2010.10 Lenovo IdeaPad U310 Touch Harbor Freight Tools 165 Amp_DC, 240 Volt, Inverter TIG/Stick Welder with High Frequency Start Product manual RCA L26WD21 Flat Panel Television User Manual Copyright © All rights reserved.
Failed to retrieve file