1. Ttem Qty Weight Description Material TS ND 1 1 578 8 Carter winder CF8M 20602 20277 2 71 9 0 Push button PTFE 25 car 20022 40452 32 1 0 Socket set screw M3x5 A2 40850 DIN 913 4 2 0 8 Spring of wiper 1 4310 12611 5 1 18 9 Axle of wiper AISI 316 20023 40453 6 1 0 1 O Ring 26 07x1 78 FFPM 20526 Tul 2 6 Gasket for sight amp cover Caoutchouc 20029 40459 8 1 0 2 Gasket for sight glass FEP 21036 40985 9 1 0 6 Wiper PTFE 12097 30700 10 1 2 0 Slotted pan head mach screw M2 5x8 A2 40705 ISO1580 11 1 41 2 Frame of sightglass 1 4301 20024 40454 12 1 13 2 Sightglass Verre 20026 40456 A 13 6 4 0 Socket head cap screw M4x30 A2 40310 DIN 912 14 1 0 4 O Ring 244 17x1 78 FFPM 20046 15 1 57 3 Sightglass holder PVDF 21046 30524 TOLERANCES UNLESS OTHERWISE SPECIFIED Weight 16 1 5 5 Wiper PTFE 10535 30237 Norm Size Over 6 so 100 300 100 ISSUE 1 10 08 2009 17 1 7822 Tape assy w o winder 35m 10389 40803 Fit Te e 30 100 300 1000 2000 9 2451 2 Eff 18 2 1 0 Slotted pan head mach screw M4x5 A2 40701 ISOT580 Fine x 10 05 0 1 015 02 03 05 0 MPSA 9 1
2. NS 9o jp Item Qty Weight Description Material TS ND 1 1 578 8 Carter winder CF8M 20602 20277 2 1 9 0 Push button PTFE 25 car 20022 40452 3 2 1 0 Socket set screw M3x5 A2 40850 DIN 913 4 2 0 8 Spring of wiper 1 4310 12611 5 1 18 9 Axle of wiper AISI 316 20023 40453 6 1 0 1 O Ring 26 07x1 78 FFKM 20526 TNA 2 6 Gasket for sight amp cover FKM 20029 40459 8 0 2 Gasket for sight glass FEP 21036 40985 9 0 6 Wiper PTFE 12097 30700 10 1 2 0 Slotted pan head mach screw M2 5x8 A2 40705 501580 11 412 Frame of sightglass 1 4301 20024 40454 12 1 13 2 Sightglass Verre 20026 40456 A 13 6 4 0 Socket head cap screw M4x30 A2 40310 DIN 912 14 1 0 4 O Ring 244 17x1 78 FFKM 20046 15 1 57 3 Sightglass holder PVDF 21046 30524 WEEE fet r vane TE 10535 30257 c SES LESS THERE SPECIES ETET 17 1 688 4 Tape assy w o winder 30m 10368 40520 Fit Te 6 30 109 300 1000 2000 Angles 2467 0 Eff eE 18 2 1 0 Slotted pan head mach screw M4x5 A2 40701 Fine x oos o1 ots o2 os os o1 MPSA 19 1 11 3 Wiper holder 14301 20028 40458 REMOVE ALL BURRS AND SHARP EDGES YYYN 20 1 20 O Ring 261 91x3 53 FFKM 20524 p cosi od E
3. TOLERANCES UNLESS OTHERWISE SPECIFIED Weight Norm Size 6 30 100 300 1000 FP to 78 736 toh 306 1999 2000 95 2178 2 Eff ISSUE 1 19 08 2008 Fine 005 01 015 02 03 os o MPSA REMOVE ALL BURRS AND SHARP EDGES YYYN Drawn Control 1 2 Replacement for Replaced by UPR 19 08 2008 Sampler 2 GTX TS 20148 Storage tube assy ND 30610 This drawing is our property and must not without our En raf Tanksystem SA permission BE copied or mage available others RUE DE L INDUSTRIE 2 CH 1630 BULLE The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 d I 2o ST f Tn f ol H TSO COSC SOY ul Wu REVISIONS Is Modification Date Visa 2 M coano soud gt Fonte inox 14 12 11 cpi ATEX Certified Product No modifications permit ted without the approval of the authorised person 13 12 11 10 9 Item Qty Weight Description Material TS ND 111 122 6 Crank casted CF8M 21034 30933 2 1 9 9 Finger 1 4401 21047 40991 3 1 8 6 Bearing 15x19x10 Bronze 21049 4 1 0 7 Ball 5 556 7 32 1 4435 11129 5 1 0 0 Spring 1 431
4. ssue 3 TSB 7021 E doc Enraf Tanksystem SA Anne es C c September 3 2008 1 of 4 Apparatus Identification HERMetic Sampler Type GT GT Chem GTX Chem GTN Chem A4 GT4 Apparatus Classification Sampling Equipment Statement of Conformity Based on sample product test results using appropriate standards industrial environment and in accordance with the following EC Directives we Enraf Tanksystem SA hereby declare under our sole responsibility that the above HERMetic Samplers are in conformity with EC ATEX Directive 94 9 EC Equipment and protective systems intended for use in potentially explosive atmospheres ATEX EC Type Examination Certificate KEMA O6ATEX0027 I 1G cllBT6 Sample Product Testing for ATEX Tested by Kema Quality B V Utrechtseweg 310 P O Box 5185 6812 AR Arnhem The Netherlands Standards Used EN13463 1 2001 Non electrical equipment for potentially explosive atmopheres Part 1 Basic method and requirements EN13463 5 2003 Non electrical equipment for potentially explosive atmopheres Part 5 Protection by constructional safety Notified Body Kema Quality B V Utrechtseweg 310 P O Box 5185 6812 AR Arnhem The Netherlands Notified Body Number 0344 Report ID KEMA 2090419 Quality Assurance notification Baseefa ATEX 1536 Notified Body Baseefa Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom Notified Body Number 1180 Manufacturer ENRAF TANKSYSTEM SA
5. 41 26 91 91 500 Fax 41 26 91 91 505 ATEX Certified Product No modifications permit ted without the approval of the authorised person Bande coup e 478 mm tape cut at 478 mm Description Tape 40m Metric inch Rivet 2 2 x 2 1 Swivel hook with clasp Washer for tape connector Norm Size Over 6 30 100 300 Fit TOLERANCES UNLESS OTHERWISE SPECIFIED Weight i 1000 1000 angie e23 cy ISSUE 1 23 06 2008 To 6 30 100 300 1000 Fine t 0 05 0 1 0 15 0 2 0 3 Drawn CPI Sampler 2 GT 90s 0 1 945 02 63 93 9 MPSA REMOVE ALL BURRS AND SHARP EDGES 1000 Control 1 1 24 06 2008 oS for Replaced by ND T 10389 Tape assy w o winder 35m REF ND 30564 20320 This drawing is our property and must not without our Enraf Tan ksystem SA permission be copied or made available to others The receiver is responsible for every misuse RUE DE L INDUSTRIE 2 CH 1630 BULLE Tel 41 26 91 91 500 Fax 41 26 91 91 505 ATEX Certified Product No modifications permit ted without the approval of the authorised person La emay Weight Description 1 _ 97 Check valve seat 1 0 7 Ball e 5 556 7 37 14455 ito 1 0 Spring 14810 20103 1 1 6 Spring holder 1 4401 20105 40808 1 1 3 Tube 1 4401 20099 40804 1 0 0 O Ring 4 47x1 78 FFPM 21050 1 6 0 Sac
6. 7 3 2 Tape cleaning If tape requires cleaning it has to be unwound preferably on another reel 7 4 Tape wiper adjustment or replacement Check the wear of the wiper If necessary adjust it or replace it Unscrew the 2 wing screws to remove the carter winder Dismantle the wiper holder by unscrewing the 2 screws Remove the wiper of its box Use the Allen key 1 3 mm to set the 2 wipers screws properly or exchange it Put back the wiper holder and tighten the 2 screws Reassemble the carter winder on the storage tube and tighten the 2 wing screws 7 5 Tape replacement Remove the carter winder from the sampler 2 wing screws M5x20 Remove the tape wiper Unwind totally the old tape Remove the cover for winder 5 screws M4x10 side opposite to crank Slacken the tape from the core Remove it and unscrew the screw M4x30 tightening to the core Put the new tape Fasten the tape to the core with screw M4x30 Wind the new tape Put back the cover for winder and tighten the 5 screws M4x10 Put back and adjust the tape wiper Put back the carter winder and tighten the 2 wing screws M5x20 Check the tape winder for gas tightness 0 3 bar 4 4 psi before using again 7 6 Bearings Bearings are involved in the electrical safety of this device In case of exchange use only original spare parts 50442 SGTX 1305 18 HERMetic Sampler GTX Chem Honeywell 7 7 Storage of HERMetic devices For a proper storage of HERMetic pro
7. ATEX Tape cleaning device Available bottles Maintenance Specifications subject to change without notice 50442 SGTX 1305 KEMA O6ATEX 0027 Il 1 Gc IIB T6 Ta 20 to 80 C Adjustable tape cleaner Zone bottom spot running sampling bottles modular design easy exchange of parts HERMetic Sampler GTX Chem Honeywell 9 Drawings amp Declaration of Conformity These documents are enclosed in following pages 9 1 Sampler O z Option according to specific order esd SSC SCRIPTION mma me SemerGCem G xs sms saperak orema me ume lt a winder FRM assy O G axo nea Caner winder FFKM assy 5m xe me Sempehtems O ws wma GmkmwF x mm WePIE e mm Tape assy wo winderaom G i imm Tape assy wiowinderasm me aen KmmpeaveswFRK swa mme mettendo FFM assy O G mer w __Botlom bole 040 FFKM assy o ami zm Sete oorr o ame zw Running bole 401 FKKM 9 2 Valves Important Valves are supplied separately from Samplers There are not included in Sampler scope of supply 39 o O aes ime VaweGzSSW z tange DUI weahoroap cames 10082 Vave C2 S SEC 2 tange DU securiy cover ace ime Vave C2 SS L Z fange DUJ bind cover 30391 10076 Valve C2 SS W 2 female weather cap 30374 10078 Valve C2 SS SEC 2 female security cover 830596 1
8. TOLERANCES UNLESS OTHERWISE SPECIFIED Weight Wore Size Over 30 100 300 wo 5437 Th ISSUE 2 16 2 1999 Fit To 30 100 300 1000 2000 9 0 Eff Fine 0 05 0 17 0 15 0 2 0 3 0 5 0 1 MPSA Body DUJ 14408 REMOVE ALL BURRS AND SHARP EDGES 3110 Ea Seat 53 66 x 6 PTFE Spore Control 1 2 Replacement for Replaced by Stem packing 17 23 9 x 8 5 2pces PTFE Z UPR 27 11 1996 CP 06 01 1997 ND ND Gland AISI 304 2 Nut AISI 304 Va ves TS 10082 Spring washer ACE S HERMetic Compact Valve C2 SS SEC No 20287 andle AISI304 PE 7 fl DUJ End cap 1 4408 3B REF ND Ball DIN 1 4436 ES ange Stem AISI 316 R x This d ty ond must not without Gasket 86 90 x 2 5 PTFE s nba a ab iue Merced Enraf Tanksystem SA a permission be copied or made available to others Gasket 17 19 x 1 PTFE Th 1 ible f RUE DE L INDUSTRIE 2 CH 1630 BULLE Washer for cable on valve AISI 304 e e receiver is responsible for every misuse Tel 41 26 91 91 500 Fox 41 26 91 91 505 TS 10413 ND 202853 Valve fits on flange DIN PN10 DN50 DIN PN16 DN50 DIN PN25 DN50 DIN PN40 DN50 JIS JIS ANS Body DUJ 5K 50 10K 50 150lbs 2 1 4408 2105 2125 Seat 53 66 x 6 PTFE Stem packing 17 23 9 x 8 5 2pces PTFE Gland AISI 304 Nut A
9. 0 401 1 4432 3 O Ring 234 65x1 78 FFPM Seat PTFE 25 car Spot upper valve 1 4401 TOLERANCES UNLESS OTHERWISE SPECIFIED We cp ss so e PE UE Fine t 0 05 0 1 0 15 0 2 0 3 05 0 1 REMOVE ALL BURRS AND SHARP EDGES Drawn Control 1 1 Replacement for Replaced by UPR 05 09 2008 ND Sampler 2 GTN Chem TS 20134 Spot bottle 0 40 FFKM ND 20253 This drawing is our property and must not without our E nraf Tanksystem SA RUE DE L INDUSTRIE 2 CH 1630 BULLE permission be copied or made available to others The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 ATEX Certified Product No modifications permit ted without the approval of the authorised person R AN A A A A E A T T E E E T E T T T E E E T E A E E E E I T E E E A T T E E E T A T T E E E A E T E E E A E E T T E E A A T T T E MME NN aaa ae 2 aasa S SSS E 02787004 me OR ZA VVOO wr ar tar a AW a a A A A E E T A A A A S AE E E E E A E A E AE E A E E E A ea sr wn AM hr 494 EE E AET E AE E DE D A EE AE E E E EE A AEE AEE A EE E m CE Y AE AE E E A E A A E A A E A AE Sh AAT A A a e recA SA hss 0 Seat PTFE 25 car 7 Bottom plug 1 4401 2 O Ring 225 12x1 78 FFPM O Ring 234 65x1 78 FFPM Stem 1 4401 806 7 Bottle 0 40 1 4432 67 0 Calibration plug 1 4401 22 9 Cap PTF
10. 11 3 Wiper holder 14301 20028 40458 REMOVE ALL BURRS AND SHARP EDGES YYYN 20 1 2 0 O Ring 261 91x3 53 FFPM 20524 Drawn Control 1 1 Replacement for Replaced by 21 1 27 1 Tape holder PTFE 25 car 21041 40989 CP 11 08 2009 ND ND 22 1 3 0 Slotted cheese head mach screw M4x30 A2 40800 ISO1207 NT 23 2 199 Washer PTFE 25 car 20607 41014 Speciality TS 98112A 24 2 287 5 Cover CF8M 20603 30539 24 12 1 207 Gorey ean 22 20009 30539 Carter winder FFKM assy __ Nb 20330 26 5 2 0 Socket head cap screw M4x10 A2 40302 DIN 972 35 m REF ND 20158 20190 27 5 2 0 E head cap screw M4x12 A2 EE DIN 912 E 28 1 214 7 Crank assy 0545 i ina 282 0 2 FOI Forseal ring 216 PTFE 25 car 21059 This drawing is ou property andimust not without our Enraf Tanksystem SA F3012 17 6 Bearing 16x22x12 Bronze 71062 permission be copied or made available to others RUE DE L INDUSTRIE 2 CH 1630 BULLE 31 1 23 8 Washer 20606 30540 The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 ATEX Certified Product No modifications permit ted without the approval of the authorised person Description COUPE A A 1423 0 Tube assy 640 9 Female quick coupler 10 0 Special nut G 1 4 16 6 Bushing G 1 4 G 1 8 AISI 316 52 1 Valve G 1 4 female Cylindrical thread 5 5 Pivot A1 84 Wing screw 7 5 Elbow 6
11. Em Replaced b 21 1 27 1 Tape holder PTFE 25 car 21041 40989 CPI 22 11 2010 ND ND 22 1 3 0 Slotted cheese head mach screw M4x30 A2 40800 ISO1207 23 2 75 6 Washer 14404 20607 41014 Sampler 2 GT TS 10316 24 2 287 5 Cover CF8M 20603 30539 i 24 2 267 5 Cover_ Crem 20603 30539 Carter winder FFKM assy ND 20281 26 5 2 0 Socket head cap screw M4x10 A2 40302 DIN 912 REF ND 20158 20190 2715 20 Socket head cap screw M4x12 A2 40303 EIE 28 1 214 5 Crank assy 10314 30 inq i P 2812 0 2 FOI Forseal ring 216 PTFE 25 car 21059 This drawing Is our property sind must net without our Enraf Tanksystem SA 3012 17 8 Bearing 16x22x12 Bronze 21062 permission pe copied or made available b others RUE DE L INDUSTRIE 2 CH 1630 BULLE 31 1 23 8 Washer 20606 30540 The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 COUPE A A J i Z a 9 eoe PA s N M Y COUPE B B ATEX Certified Product No modifications permit ted without the approval of the authorised person
12. identify the spare part by TS number and description Refer to section Drawings Some spares might be repairable in this case send part to any authorized service center or to the factory In case of urgency replacement units can be available while stocks last 50442 SGTX 1305 Honeywell 3 7 Service and Repair The customer should take care of the freight and customs clearance charges If units are sent on freight collect the charges will be invoiced to the customer When returning units or parts for repair to the factory please fill out a service request form see next page Traceability information is engraved on a plate fixed to the sampler The serial number of the unit is as follows SX followed by a 4 digits number When returned to Enraf Tanksystem SA equipment must be contamination free If it is determined that the customers equipment is contaminated it will be returned to the customer at the customers expense Contaminated equipment will not be repaired until such time that the customer decontaminates the said equipment HERMetic Sampler GTX Chem Honeywell Service Request Customer s address ccccecceccecceccecceccecceceuceeceecauceecaecaucaeeeeseeseceeeeeeees Telephone e A l e coo CER RRRKE E Type OT UN liifo aep EEA a 50442 SGTX 1305 6 HERMetic Sampler GT
13. other usage is authorized Unauthorized repair or component replacement by non original spare parts by the Purchaser will void this guarantee and may impair the good functioning of the instrument In no event shall Enraf Tanksystem SA be liable for indirect incidental or consequential loss or damage or failure of any kind connected with the use if its products or failure of its products to function or operate properly Enraf Tanksystem SA do not assume the indemnification for any accident or damage caused by the operation of its product and the warranty is limited to the replacement of parts or complete goods HERMetic Sampler GTX Chem 3 5 Certification Enraf Tanksystem SA is an ISO 9001 certified as company by Intertek and 8888 MED D by Det Norske WP p EN Senex DIN V Veritas Certification Certified GmbH Intertek Company The equipment has been approved as non electrical equipment for potentially explosive atmospheres by the following authorities ATEX KEMA O6ATEX 0027 II 1 Gc IIB T6 Ta 20 to 80 C If you need a copy of any of this certificate please contact Enraf Tanksystem SA Rue de l industrie 2 1630 Bulle SWITZERLAND Telephone 41 26 91 91 500 Telefax 3441 26 91 91 505 Web site www tanksystem com E mail tanksystem honeywell com 3 6 Spare parts Substitution of components may impact safety Use only original spare parts When ordering spares
14. 0 20103 6 1 0 0 O Ring 24 47x1 78 FFPM 21050 7 1 1 3 Tube 1 4401 20099 40804 8 1 1 6 Spring holder 1 4401 20105 40808 9 1 44 7 Knob PF 31 21048 40992 10 1 9 3 Washer PE HD 11052 40563 11 1 3 0 Prevailing torque hex nut M5 A2 40009 DIN 985 12 1 0 6 Cap for knob PE HD 11054 40182 13 1 0 5 Crank spring 1 4310 11500 TOLERANCES UNLESS OTHERWISE SPECIFIED Weight S N Si O 6 30 100 300 1000 E Ft Te e 30 100 300 1000 2000 9e 200 1 Eff ISSUE 2 14 12 2011 Fine 0 05 0 1 0 15 02 03 05 0 1 MPSA REMOVE ALL BURRS AND SHARP EDGES YYYN H Drawn Control 2 1 Replacement for Replaced by CPI 19 01 2012 ND ND Sampler 2 GT TS 10314 Crank assy FFKM ND 30545 REF ND 20281 This drawing is our property and must not without our Enraf Tanksystem SA permission be copied or made available to others RUE DE L INDUSTRIE 2 CH 1630 BULLE The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 Le x M 5 Ne I Lo S ATEX Certified Product No modifications permit ted without the approval of the authorised person eU E 4 COUPE A A 3Wiper holder 3 Wiper PTFE 25 car Spring for wiper PTFE 1 4310 Rod 2 5x20 Socket set screw M2 5x8 TOLERANCES UNLESS OTHERWISE SPECIFIED Norm Size Over 6 30 100 300 1000 Fit To 6 30 100 300 1000 2000 Fine oo5 01 015 o2 o3 o5 Weight 5
15. 0085 Valve C2 SS BL G2 Female blind cover 9 3 Declaration of Conformity 50442 SGTX 1305 21 HERMetic Sampler GTX Chem ATEX Certified Product No modifications permit ted without the approval of the authorised person COUPE A A 206 801 119 Description TOLERANCES UNLESS OTHERWISE SPECIFIED Weight Norm Size Over 6 30 100 300 1000 Fit To 6 30 100 300 1000 2000 9 5 12178 6 Eff ISSUE 1 19 08 2008 2 Storage tube assy A Carter winder FFKM assy 9 O Ring 256 74x3 53 Kit pump connector FFKM 4 Zone bottle 0 431 FFKM assy Pump Zephal 23 0 Sachet PEBD 90x75 Hexagon key 1 3mm x Carrying case S2GT Label Sampler Label U S Patent 5408890 Label Enraf Tanksystem Identification plate TS 10086 SX nnnn Round head grooved pin 1 4x4 Fine x oos 01 015 o2 o3 o5 0 1 REMOVE ALL BURRS AND SHARP EDGES Drawn Control 1 2 UPR 19 08 2008 Sampler 2 GTX Sampler GTX Chem Assembly This drawing is our property and must not without our permission be copied or made available to others MPSA Replacement for Replaced by ND TS 10086 ND 20324 Enraf Tanksystem SA RUE DE L INDUSTRIE 2 CH 1630 BULLE The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 ATEX Certified Pr
16. 01 MPSA REMOVE ALL BURRS AND SHARP EDGES YYYN Drawn Control 1 1 Replacement for Replaced by CPI 30 05 2011 ND ND Sampler 2 GT TS 10374 Zone bottle 0 43l FFKM assy Np 30293 REF ND 20158 This drawing is our property and must not without our permission be copied or made available to others The receiver is responsible for every misuse Enraf Tanksystem SA RUE DE L INDUSTRIE 2 CH 1630 BULLE Tel 41 26 91 91 500 Fax 41 26 91 91 505 ATEX Certified Product No modifications permit ted without the approval of the authorised person ISNA nL goer teers N D 45 lt 9 OL CAS A A esi A ae LI eens ial SS DL Bra hb ooo EZ FBS E DLL la a a a a a a a a E a a a a a a a a a a WA AGA SST eu LII Im va T De ja S ELS MET ZZ 7 N Ran D E A AE A E S EN Item Oty Weight Description Material TS ND 1 1 8 8 Bottom valve 1 4401 20125 40962 jA 0 1 O Ring 6 75x1 78 FFPM 12057 3 1 39 2 Seat PTFE 25 car 20131 30495 4 2 0 3 O Ring 234 65x1 78 FFPM 20045 51 71 1 Rod 1 4401 20126 40963 61 806 7 Bottle 0 40 1 4432 20112 30462 T 149 5 Top cover 1 4401 20128 30494 8 1 0 1 O Ring 29 25x1 78 FFPM 20527 9 1 7 5 Upper valve 1 4401 20130 40961 10 2 2 0 Hex nut M5 A2 40005 IS04032 1111 2 0 Socket set sc
17. 2 0 3 0 5 0 1 i i ER TE PLA z MPSA Body DUJ 14408 REMOVE ALL BURRS AND SHARP EDGES 3110 Ea Seat 53 66 x 6 PTFE Drawn Control f 2 Replacement for Replaced by Stem packing 17 23 9 x 8 5 2pces PTFE PR 27 11 1996 CPI 06 01 1997 ND ND Gland AISI 304 Nut AISI 304 Spring washer AISI 304 Valves TS 10083 HERMetic Compact Valve C2 SS W up 20291 is Date Visa Modification Handle AISIS04 PE A End cap 1 4408 2 fl ange DUJ REF ND Ball DIN 1 4436 Stem AISI 316 amem This drawing is our property ond must not without our Gasket 86 90 x 2 5 PTFE hai ib ob doen Enraf Tanksystem SA permission be copied or made available to others Gasket 17 19 x 1 PTFE 1 1 RUE DE L INDUSTRIE 2 CH 1630 BULLE The receiver is responsible for every misuse RUE DE LS INDUPIR IE 2 GH MESE HULLE Washer for cable on valve AISI 304 zl TS 10413 ND 20283 Valve fits on flange DIN PN10 DN50 DIN PN16 DN50 DIN PN25 DN50 DIN PN40 DN50 JIS 5K 50 JIS 10K 50 ANSI 150lbs 2 2125 2120 6 Irem Ot Weight Description Material 1S NDF a 1 4480 Compact valve C2 DUJ E 10413 20283 2 12 957 Security cover w lock 10508 40495
18. 2 ball valve 50442 SGTX 1305 14 HERMetic Sampler GTX Chem Honeywell 6 4 Operating the SPOT SAMPLING BOTTLE O 20253 20134 Spot bottle 0 40 FFKM Install the HERMetic Sampler GTX Chem with the sampling bottle on top of the HERMetic 2 ball valve by means of the quick connect coupling In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge the Sampler after it has been installed on the HERMetic 2 ball valve but before opening it Check that the HERMetic 2 ball valve is closed Open the transfer valve Install an inert gas bottle to the pump connector The inert gas pressure shall not exceed 0 3 bar Apply the inert gas through the pump connector to purge the HERMetic Sampler 1 1 1 1 1 5 After purging close the transfer valve akWND Prepare the hose connection from the transfer valve to the laboratory bottle Check that its capacity is at least 0 5 l Open the HERMetic 2 ball valve Lower the spot bottle to the level where the sample is to be taken Stop the bottle at this level and shake it rapidly up and down about 10 times on a 100 mm stroke This movement has a pumping effect as the bottom ball of the container opens and closes quickly Lift the bottle back into the HERMetic Sampler housing turn the crank until getting a catch that keeps the tape fully tight Close the HERMetic 2 ball valve Lower the sampling bottle unt
19. 5 Eff REMOVE ALL BURRS AND SHARP EDGES Drawn Control 5 1 UPR 08 08 2007 Sampler 2 GT Wiper PTFE Angles 0 1 This drawing is our property and must not without our permission be copied or made available to others The receiver is responsible for every misuse A2 A4 ISSUE 1 8 8 2007 MPSA Replacement for Replaced by TS 10535 ND 30237 Enraf Tanksystem SA RUE DE L INDUSTRIE 2 CH 1630 BULLE Tel 41 26 91 91 500 Fax 41 26 91 91 505 ATEX Certified Product No modifications permit ted without the approval of the authorised person Bande coup e 478 mm Tape cut at 478 mm Description Tape 30 m Metric inch Rivet 2 2 x 2 1 Swivel hook with clasp Washer for tape connector Norm Size Over 6 30 100 300 Fit To 6 30 100 300 1000 TOLERANCES UNLESS OTHERWISE SPECIFIED Weight i 1000 2000 Angles 687 2 Eff ISSUE 1 23 06 2008 Fine 0 05 0 1 0 15 0 2 0 3 Drawn CPI Sampler 2 GT Tape assy w o winder 30m 905 4T 945 02 03 Ml MPSA REMOVE ALL BURRS AND SHARP EDGES 1000 Control 1 1 24 06 2008 MUS for Replaced by ND T 10368 REF ND 20280 20281 This drawing is our property and must not without our Enraf Tan ksystem SA permission be copied or made available to others The receiver is responsible for every misuse RUE DE L INDUSTRIE 2 CH 1630 BULLE Tel
20. ATES P O Box 6488 Fax 971 4 3242500 Shed 72 Jadaf Ship Docking Yard service maritronics com DUBAI UNITED ENERGY MARINE INTERNATIONAL LTD Tel 44 1525 851234 KINGDOM 12 Clipstone Brook Industrial Estate Fax 44 1525 852345 Cherrycourt Way info engmar com LEIGHTON BUZZARD BEDS LU7 4TX U S A TEXAS HONEYWELL HERMETIC Tel 1 281 930 1777 4522 Center Street Fax 1 281 930 1222 DEER PARK TX 77536 Toll free call in the USA 1 800 900 1778 hermetic honeywell com 50442 SGTX 1305 8 HERMetic Sampler GTX Chem Honeywell 5 Description 5 1 General The HERMetic Samplers are designed for closed sampling of liquids or chemicals which present a Fire Health or Air pollution Hazard The gas tight construction of these units avoids a pressure release from the tank and exposure to fumes during operation The equipment is designed and certified for use in potentially explosive atmospheres area 5 2 Sampling types Several kinds of samples can be realised with this sampler To get different samples 4 bottles are available Zone bottle Spot bottle Running bottle and Bottom bottle The Zone bottle allows sampling of the upper level inside the tank The Spot bottle allows sampling at a determinate height The running bottle allows sampling all along the displacement of the bottle inside the tank The Bottom bottle allows sampling of the tank bottom As far as the kinds of sampling are concerned please refer to ISO 3170 Petro
21. ATIONS 20 9 DRAWINGS amp DECLARATION OF CONFORMITY 21 9 1 SAMPLER 21 9 2 VALVES 21 9 3 DECLARATION OF CONFORMITY 21 50442 SGTX 1305 2 HERMetic Sampler GTX Chem Honeywell 2 Recommendation for safe use l This Operation and Service Manual is a guide in order to help the user to operate the instrument to safely and correctly Il Nevertheless the maker disclaims all responsibility and liability for damage resulting from the use of the equipment regardless of the cause of the damage Ul Attention is drawn to the possible hazard due to electrostatic charges which may be present in the tank This may happen in particular with static accumulator liquids i e liquids which have low conductivity of 50 picoSiemens metre pS m or less IV It is very important that the instrument is grounded to the tank before the bottle is introduced into the tank and remains grounded until after complete withdrawal from the tank A If the instrument is installed with the quick connect coupler grounding is effected through the quick connect coupler and the mating nipple of the valve provided that these parts are kept clean and free from corrosion in order to guarantee electrical conductivity If a grease is used for this purpose it must be one which contains graphite B If the instrument is not connected to the mating deck valve the instrument has to be also earthed by means of the grounding cable and clamp V It is anticipated that the user w
22. E 25 car 3 0 Circlip 010 AISI 431 16 5 Coupling stem 1 4401 0 0 Cotter pin 2x10 A2 TOLERANCES UNLESS OTHERWISE SPECIFIED Weight Nom Size O 6 3o 100 300 1000 NEN RN e 30 100 300 1000 2000 9 1146 3 Eff ISSUE 3 04 09 2008 Fine oos 01 ots o2 os os or MPSA REMOVE ALL BURRS AND SHARP EDGES YYYN f Drawn Control 1 1 Replacement for Replaced by UPR 04 09 2008 ND ND Sampler 2 GTN Chem TS 20117 Running bottle 0 40 I FFKM This drawing is our property and must not without our E nraf Tanksystem SA RUE DE L INDUSTRIE 2 CH 1630 BULLE permission be copied or made available to others The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 112 TS 10413 20283 SS XS ES g i A y le e m m Hh S Valve fits on flange DIN PN10 DN50 DIN PN16 DN50 a JIS 10K 50 N 2 S ANSI 150lbs 2 2120 6 Item t Weight Description Material TS 3 NDF a 1 4480 Compact valve C2 DUJ E 10413 20283 2 12 590 Cover with weather cap x 10415 41040 TOLERANCES UNLESS OTHERWISE SPECIFIED Weight Tae Se s uw o ooo 5070 T SSUE 2 16 2 1999 it To 6 30 100 300 1000 2000 0 Eff Fine 0 05 0 100 154 0
23. Honeywell Operation and Service Manual for HERMetic Sampler GTX Chem Portable Closed Sampling Device Note Before using the instrument please read this book DNY 3 Certified nr Company Intertek This document is subject to changes without notice Check updates on www tanksystem com or contact us at tanksystem honeywell com 50442 SGTX 1305 1 HERMetic Sampler GTX Chem Honeywell 1 Table of contents 1 TABLE OF CONTENTS 2 2 RECOMMENDATION FOR SAFE USE 3 3 GENERAL INFORMATION 4 3 1 SHIPMENT NOTE 4 3 20 INITIAL INSPECTION 4 3 3 DOCUMENTATION DISCREPANCIES 4 3 4 WARRANTY 4 3 5 CERTIFICATION 5 3 6 SPAREPARTS 5 3 7 SERVICE AND REPAIR 5 4 WORLDWIDE SERVICE STATIONS NETWORK OT 5 DESCRIPTION 9 5 1 GENERAL 9 5 2 SAMPLING TYPES 9 5 3 SAMPLING PRINCIPLE 10 5 3 1 CONNECTION AND GROUNDING SYSTEM 10 5 3 2 SAMPLING METHOD 11 5 3 8 LIQUID TRANSFER 11 6 OPERATION 12 6 1 CHECKING BEFORE USE 12 6 2 OPERATING THE ZONE SAMPLING BOTTLE 13 6 3 OPERATING THE BOTTOM SAMPLING BOTTLE 14 6 4 OPERATING THE SPOT SAMPLING BOTTLE 15 6 5 OPERATING THE RUNNING SAMPLING BOTTLE 16 7 CARE amp MAINTENANCE 17 7 1 SAFETY WARNING 17 7 2 CARE 17 7 3 SAMPLER CLEANING 18 7 3 1 CARTER WINDER 18 7 3 2 TAPE CLEANING 18 7 4 TAPE WIPER ADJUSTMENT OR REPLACEMENT 18 7 5 TAPE REPLACEMENT 18 7 6 BEARINGS 18 7 7 STORAGE OF HERMETIC DEVICES 19 7 8 TRANSPORTATION OF HERMETIC DEVICES 19 7 9 RECYCLING OF HERMETIC DEVICES 19 8 SPECIFIC
24. ISI 304 Spring washer AISI 304 Handle AISI304 PE End cap 1 4408 Ball DIN 1 4436 Stem AISI 316 Gasket 9 86 90 x 2 5 PTFE Gasket 17 19 x 1 PTFE Washer for cable on valve AISI 304 9o iS 2120 6 Irem ut Weight Description Material TS 3 ND f a a 4 amp 80 Compact valve C2 DUJ 10473 20283 2 370 Blind cover ass 10414 41034 TOLERANCES UNLESS OTHERWISE SPECIFIED Weight Tora Size Over 3 30 T 4850 Th lSSUE 2 16 2 1999 Fit To 30 100 30 1000 2000 9 O Eff Fine x 1005 01 1015 07 03 o5 or MPSA REMOVE ALL BURRS AND SHARP EDGES 3110 Ea Sf drawn Control 2 Replacement for Replaced by SLUPR 27 11 1996 CP 06 01 1997 ND Valves TS 10081 HERMetic Compact Valve C2 SS BL up 20288 REF ND 2 flange DUJ is Date visa voditi This draving is our property and must not without our pernission be copied or made available to others The receiver is responsible for every misuse Enraf Tanksystem SA RUE DE L INDUSTRIE 2 CH 1630 BULLE Tel 41 26 91 91 500 Fox 41 26 91 91 505 zl SS SESS BER M WS ENS F Weight Description Cover with weather cap 10415 41040 TOLERANCES UNLESS OTHERWISE SPECIFIED SSUE 3 25 6 1 999 Over 30 100 300 1000 ep pepe pespe
25. Rue de l industrie 2 1630 BULLE Switzerland nt m e Philippe Despagne General Manager Created modified Approved Released Remarks O O SSS O Update of the company logo Honeywell The prints of this document are not controlled under the quality management system unless printed on ORIGINAL paper KAQUALITYVSO 900117000 Checking ListsYTSB 7021 E doc Printed 28 08 08 14 25
26. X Chem Honeywell 4 Worldwide Service Stations network The updated list can be found on our website www tanksystem com COUNTRY COUNTRY ADDRESS 1 2TELEPHONEFAXEMAIL SWITZERLAND CANADA CHINA GERMANY GREECE JAPAN KOREA MEXICO NETHERLANDS amp BELGIUM ADDRESS ENRAF TANKSYSTEM SA 2 rue de l Industrie CH 1630 BULLE PYLON ATLANTIC A Div Of Pylon Electronics Inc 31 Trider Crescent DARTMOUTH N S B3B 1V6 HUA HAI EQUIPMENT amp ENGINEERING CO LTD Factory 7 Lane 1365 East Kang Qiao Road Kang Qiao Industrial Zone Pu Dong SHANGHAI P C 201315 CHRISTIAN BINDEMANN MARINE TECHNICAL SERVICES Antonie M bis Weg 4 HAMBURG 2523 SPANMARIN 86 Filonos Street GR 185 36 PIRAEUS DAIWA HANBAI CORPORATION LTD 2 10 31 Mitejima Nishiyodogawa ku OSAKA 555 0012 World Ocean CO LTD Rm1001 Hae deok Bldg 1212 11 Choryang dong Dong Gu BUSAN URBAN DEL GOLFO SA DE CV Julian Carrillo No 709 Nte COL LOS MANGOS 89440 Cd MADERO Tamps MEXICO B V TECHNISCH BUREAU UITTENBOGAART Brugwachter 13 NL 3034 KD ROTTERDAM 50442 SGTX 1305 7 Tel 41 26 91 91 500 Fax 41 26 91 91 505 Tanksystem honeywell com Tel 1 902 4683344 Fax 1 902 4681203 halifax_csr pylonelectronics com Tel 86 21 68183183 Fax 86 21 68183115 huahaish huahaiee com Tel 49 40 41918846 Fax 49 40 41918847 service mkecb com Tel 30 210 4294498 Fax 30 210 4294495 span
27. d must not without our En r af Tanksys t em 9A Handle End cap permission be copied or made available to others f The receiver is responsible for every misuse P T s EPIS tus md ri Ball 2 Stem Gasket 86 90 x 2 5 Gasket 17 17 x 1 Washer for cable on yalve z Uu v 2 xmIIAB IS U Weight yyesssssysssoos07 7 p Description 0 Body 2 female Material Weight Blind cover assy TOLERANCES UNLESS OTHERWISE SPECIFIED Description Eton 47030 Weight att ERES me am PISSE 2 25 5 1999 To 100 300 1000 2000 4300 Eff 0 3 Seat 9 53 66 x 6 Stem packing 2 17 23 9 x 8 5 2pces Fine t 0 05 0 1 0 15 0 2 a 0 5 0 1 MPSA REMOVE ALL BURRS AND SHARP EDGES 1 2 4110 E gt Drawn Control Replacement for Replaced by UPR 21o oaa Gland Nut Spring washer Valves TS 10085 Handle HERMetic Compact Valve C2 SS BL End cap Ball 2 2 Fenale Stem Gasket 86 90 x 2 5 This drawing is our property and must not without our Enraf Tanksystem SA 22640 Gasket 17 19 x ermission be copied or made available to others 22641 P p RUE DE L INDUSTRIE 2 CH 1630 BULLE Washer for cable pn valve SI 304 22648 The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 Honeywell Declaration of Conformity
28. ducts UTImeter Sampler Thermometer and related spare parts we recommend Clean the devices after use Remove batteries for prolonged storage Store batteries in a dry and cold location Store the goods in a safe dry and dust free location with an ambient temperature between 5 C to 45 C 7 8 Transportation of HERMetic devices For transportation of the device always strecht out the tape to avoid any move of the the bottle inside its storage tube 7 9 Recycling of HERMetic devices Equipment does not contain any dangerous materials inside which can harm the environment and people health during normal use or disposal However the utilization and recycling of the equipment after the end of its life must be implemented by an authorized organization in accordance to local legislation 50442 SGTX 1305 19 HERMetic Sampler GTX Chem Honeywell 8 Specifications General Specifications Tape length Tape graduation Tape resolution Tape accuracy Maximum tank pressure Liquid density Ambient temperature range Maximum liquid temperature Mechanical coupling Weight Dimensions up to 35 m 115 ft Metric English 1 mm 1 16 6 3mm 35 m x1 4 115 ft approx Atmospheric pressure 0 3 bar 4 4 psi up to 8kg dm 20 C to 80 C 4 F to 176F 80 C 176 F Q2 2 5 6 kg approx 801 x 118 mm approx Meets ISO 3170 Petroleum liquids Manual sampling Hazardous environments approvals
29. e sampler itself check and clean the unit and the bottle prior to use Clean the unit with an appropriate cleaner without impacting the unit or contamination risk of the next sample 5 3 3 Liquid transfer After sampling the liquid can be transferred into a laboratory bottle through a transfer valve The transfer of the liquid from the sampling bottle to a laboratory bottle occurs by gravity The opening of the bottle valve is realized by lowering the sampling bottle until its sitting on the ball of the valve A pump can be used to accelerate and complete the transfer of the fluid 50442 SGTX 1305 11 HERMetic Sampler GTX Chem Honeywell 6 Operation 6 1 Checking before use Before using the sampler e Check the good state of the device Check the cleanliness of the unit sampler and bottle to prevent any contamination of the sample Inspect the bottle tape end for breaks kinks and wear If there is some damage replace the tape before use Check of the attachment of the hook locking device on the tape Check the closure of the hook locking device according to Fig 1 The swivel hook has to be locked in use Tape inspection f ni Hook Unlocked Fig 1 Nota Clean the instrument of any excess of liquid after use Remove the carter winder and clean the storage tube This cleaning must be done very properly in particular when corrosive liquids are gauged such as strong acids or caustic
30. e transferred liquid falls between the two marks 0 3 and 0 35 in order to comply with API MPMS Chapter 8 1 requirements Close the transfer valve Remove the pump or the inert gas bottle Lift the sampling bottle and lock the crank Open the HERMetic 2 ball valve no more than 30 to drain any residual liquid back into the tank After draining close the HERMetic 2 ball valve Remove the HERMetic Sampler GTX Chem from the HERMetic 2 ball valve 50442 SGTX 1305 16 HERMetic Sampler GTX Chem Honeywell 7 Care amp Maintenance 7 1 Safety warning As this equipment has been certified as non electrical equipment for potentially explosive atmospheres Specific precautions have to be taken regarding maintenance of the device The user can exchange parts and modules if following points are observed 1 Never carry out any repair or trouble shooting in a hazardous area 2 Substitution of components may impact safety Use only original spare parts 3 Work shall be done only by maintenance personnel who has experience with equipment certified for use in potentially explosive atmosphere The design of the equipment is modular i e in case of damage check which modules or spare parts have to be replaced Order new parts according to enclosed drawings and specific item number TS The instrument consists of the following modules e Mechanical parts e Tape assembly e Tape cleaner 7 2 Care Clean the instrumen
31. ert gas bottle to the pump connector The inert gas pressure shall not exceed 0 3 bar Apply the inert gas through the pump connector to purge the HERMetic Sampler 1 1 1 1 1 5 After purging close the transfer valve akWND Prepare the hose connection from the transfer valve to the laboratory bottle Check that its capacity is at least 0 5 l Open the HERMetic 2 ball valve Lower the bottom bottle to reach the tank bottom When the bottle bottom valve hits the tank bottom the bottle fills up automatically Lift the bottle back into the HERMetic Sampler housing turn the crank until getting a catch that keeps the tape fully tight Close the HERMetic 2 ball valve Lower the sampling bottle until sitting on the ball of the HERMetic 2 ball valve This will open the valve of the sampling bottle Open the transfer valve Install the pump to the pump connector If the liquid is air oxygenating install the inert gas bottle set up at 0 3 bar maximum With the pump or with the inert gas transfer the liquid from the sampling bottle to the laboratory bottle When the transfer is completed close the transfer valve Remove the pump or the inert gas bottle Lift the sampling bottle and lock the crank Open the HERMetic 2 ball valve no more than 30 to drain any residual liquid back into the tank After draining close the HERMetic 2 ball valve Remove the HERMetic Sampler GTX Chem from the HERMetic
32. h that keeps the tape fully tight Close the HERMetic 2 ball valve Lower the sampling bottle until sitting on the ball of the HERMetic 2 ball valve This will open the valve of the sampling bottle Open the transfer valve Install the pump to the pump connector If the liquid is air oxygenating install the inert gas bottle set up at 0 3 bar maximum With the pump or with the inert gas transfer the liquid from the sampling bottle to the laboratory bottle When the transfer is completed close the transfer valve Remove the pump or the inert gas bottle Lift the sampling bottle and lock the crank Open the HERMetic 2 ball valve no more than 30 to drain any residual liquid back into the tank After draining close the HERMetic 2 ball valve Remove the HERMetic Sampler GTX Chem from the HERMetic 2 ball valve 50442 SGTX 1305 13 HERMetic Sampler GTX Chem Honeywell 6 3 Operating the BOTTOM SAMPLING BOTTLE oO 20247 20132 Bottom bottle 0 40 FFKM assy Install the HERMetic Sampler GTX Chem with the sampling bottle on top of the HERMetic 2 ball valve by means of the quick connect coupling In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge the Sampler after it has been installed on the HERMetic 2 ball valve but before opening it Check that the HERMetic 2 ball valve is closed Open the transfer valve Install an in
33. he Sampler with inert gas after installation on the HERMetic 2 ball valve but before opening the valve 2 1 Check that the HERMetic 2 ball valve is closed 2 2 Open the transfer valve 2 3 Install an inert gas bottle to the pump connector The inert gas pressure shall not exceed 0 3 bar 2 4 Apply the inert gas through the pump connector to purge the HERMetic Sampler 2 5 After purging close the transfer valve Prepare the hose connection from the transfer valve to the laboratory bottle Check that its capacity is at least 0 5 Draw two marks on the lab bottle at 0 3 and 0 35l Open the HERMetic 2 ball valve Lower the running bottle regularly to the appropriate depth but do not hit the tank bottom in order to keep the bottom plug closed all the time When the appropriate depth has been reached lift the running bottle back into the HERMetic Sampler GTX at the same regular speed Turn the crank until getting a catch that keeps the tape fully tight Close the HERMetic 2 ball valve Lower the sampling bottle until sitting on the ball of the HERMetic 2 ball valve This will open the valve of the sampling bottle Open the transfer valve Install the pump to the pump connector If the liquid is air oxygenating install the inert gas bottle set up at 0 3 bar maximum With the pump or with the inert gas transfer the liquid from the sampling bottle to the laboratory bottle When the transfer is completed check that th
34. het PEBD 90x75 d osas TOLERANCES UNLESS OTHERWISE SPECIFIED Weight ISSUE 4 4 2 8 2008 Over 6 30 100 300 1000 12 8 e re 6 30 100 30 1000 2000 9 134 Ef REMOVE ALL BURRS AND SHARP EDGES Drawn Control 2 1 Replacement for Replaced by UPR 1208208 Sampler 2 GT TS 20611 Kit pump connector FFKM ND 41021 This drawing is our property and must not without our Enraf Tanksystem SA permission be panied or made available Ia others RUE DE L INDUSTRIE 2 CH 1630 BULLE The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 ATEX Certified Product No modifications permit ted without the approval of the authorised person o i E A cv 7 D a ig X LI X V 4 t V if t J 2 3 PP A v i 505 Item Qty Weight Description Material TS ND TIa 872 3 Bottle 0 43 I 1 4404 20048 30294 2 1 113 1 Seat 1 4435 20049 40592 311 24 7 Bottom valve PTFE 20050 41062 411 4 2 Valve screw PVDF 20051 40593 5 1 0 3 O Ring 34 65x1 78 FFKM 20045 TOLERANCES UNLESS OTHERWISE SPECIFIED Weight ss Norm Size Over 6 30 100 300 1000 E Fit To 6 30 100 300 1000 2000 9e 1014 6 Eff UE 2 13 8 2008 Fine oos 01 0 15 02 o3 05
35. his product and his use is may be related to international national local or company regulations or standards It is the customer user responsibility to ensure that the way to use the device complies with such applicable regulations or standards VIII This device is a portable product It must not be permanently installed on the tank and must be disconnected after use and stored in a safe and dry area 50442 SGTX 1305 3 HERMetic Sampler GTX Chem Honeywell 3 General information 3 1 Shipment note The following parts should be included in the shipment 1 instrument 1 Allen key 1 3 mm 1 pump 1 or more bottles as ordered 1 Operation and Service Manual 3 2 Initial inspection Check the contents of the shipment for completeness and note whether any damage has occurred during transport Carry out the Initial test before installing the instrument to verify the good functioning If the contents are incomplete or if there is damage do not use the device A claim should be filled with the carrier immediately and Enraf Tanksystem SA Sales or Service organization should be notified in order to facilitate the repair or replacement of the instrument 3 3 Documentation discrepancies The design of the instrument is subject to continuous development and improvement Consequently the instrument may incorporate minor changes in detail from the information contained in the manual 3 4 Warranty 12 mon
36. il sitting on the ball of the HERMetic 2 ball valve This will open the valve of the sampling bottle Open the transfer valve Install the pump to the pump connector If the liquid is air oxygenating install the inert gas bottle set up at 0 3 bar maximum With the pump or with the inert gas transfer the liquid from the sampling bottle to the laboratory bottle When the transfer is completed close the transfer valve Remove the pump or the inert gas bottle Lift the sampling bottle and lock the crank Open the HERMetic 2 ball valve no more than 30 to drain any residual liquid back into the tank After draining close the HERMetic 2 ball valve Remove the HERMetic Sampler GTX Chem from the HERMetic 2 ball valve 50442 SGTX 1305 15 HERMetic Sampler GTX Chem Honeywell 6 5 Operating the RUNNING SAMPLING BOTTLE O 20216 20117 Running bottle 0 40 FFKM The calibration plug on top of the running bottle has to be adjusted according to the liquid to be sampled The plug is properly set up when the transferred quantity of liquid falls between 70 and 85 of the capacity of the sampling bottle i e between 0 3 and 0 35 API MPMS Chapter 8 1 8 3 3 3 Install the HERMetic Sampler GTX Chem with the sampling bottle on top of the HERMetic 2 ball valve by means of the quick connect coupling In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge t
37. ill have specific operating methods laid down to ensure safety when using this type of apparatus In this case the user s instructions shall be strictly observed VI In the absence of such instructions the following should be noted A If a metal sounding pipe is fitted beneath the deck valve or tank is inerted then sampling etc is permissible at any time with no restriction B If there is no sounding tube or tank is not inerted the following precautions shall be taken 1 If the cargo is not a static accumulator liquid i e its conductivity is more than 50pS m then sampling is permitted provided that the instrument is properly grounded and earthed before the bottle is inserted into the tank and remains earthed until the bottle has been removed from the tank 2 If the cargo is a static accumulator liquid i e its conductivity is less than 50 pS m then sampling is permitted provided that a The instrument is properly grounded and earthed before the bottle is inserted into the tank and remains earthed until the bottle has been removed from the tank b The apparatus is not introduced into a tank until at least 30 minutes have elapsed after completion of any loading operation or stopping the injection of inert gas C For further guidance refer to International Safety Guide for Oil Tankers and Terminals ISGOTT ISBN 10 85609 291 7 Fith Edition 2006 or consult the appropriate Legislative Authority for the installation VII T
38. leum liquids Manual sampling Different kinds of samplings Running A All these bottle are interchangeable please refer to S 6 1 For specific application other bottles exist For further information please contact The sampler is delivered as standard with zone sampling bottle All other sampling bottles are available as option 50442 SGTX 1305 9 HERMetic Sampler GTX Chem Honeywell 5 3 Sampling principle 5 3 1 Connection and grounding system All HERMetic products are easy to connect Indeed all HERMetic devices are equipped with a quick coupler for connection on a HERMetic ball valve Place the unit on the appropriate valve and activate the locking system Depending on the locking system either rotate the collar and actuate the lever or pull on the sleeve If the instrument is connected to genuine HERMetic valve grounding is effected through the quick connect coupler and the mating nipple of the valve No additional grounding strap is necessary For further information please refer to 2 Recommendation for safe use 50442 SGTX 1305 10 HERMetic Sampler GTX Chem Honeywell 5 3 2 Sampling method The sample is taken by a vertical move of the bottle inside the fluid The bottle is linked with a graduated tape A reading window allows monitoring the bottle location For complete explanation of sampling procedures please refer to S6 Operation Important note to avoid contamination of the sample taken by th
39. marin ath forthnet gr Tel 81 6 64714701 Fax 81 6 64729008 daiwa471 silver ocn ne jp Tel 82 51 462 2554 5 Fax 82 51 462 0468 info worldocean co kr Tel 52 833 2170190 Fax 52 833 2170190 urbansa prodigy net mx Tel 31 10 4114614 Fax 31 10 4141004 info tbu nl HERMetic Sampler GTX Chem Honeywell The updated list can be found on our website www tanksystem com COUNTRY ADDRESS TELEPHONE FAX E MAIL PORTUGAL CONTROLIS Lda Tel 351 21 2740606 Rua Conceic o Sameiro Antunes 26 E Fax 351 21 2740897 Cova da Piedade controlis port gmail com 2805 122 Almada RUSSIA NPP GERDA Tel 7 495 7558845 Vilisa Latsisa str 17 Fax 7 495 7558846 Building 1 info gerda ru 125480 MOSCOW SINGAPORE HUBBELL INT L 1976 PTE LTD Tel 65 6 2557281 322 Thomson Road Tel 65 6 2550464 SINGAPORE 307665 Fax 65 6 2532098 hubbell mbox2 singnet com sg SPAIN E N I Tel 34 94 4746263 Electronica y Neumatica Industrial S A Fax 34 94 4745868 C Jon Arrospide 20 Int eni tecnica Qeni es 48014 BILBAO SWEDEN INSTRUMENTKONTROLL Tel 46 31 240510 Lars Petersson AB Tel 46 31 240525 Varholmsgatan 1 Fax 46 31 243710 414 74 GOTEBORG Info instrumentkontroll se TURKEY YEDI DENIZ Tel 90 212 251 64 10 3 lines Setustu Izzetpasa Yok 1 Fax 490 212 251 05 75 TR 34427 Kabatas ISTANBUL servicestation yedideniz net dmgistanbul yahoo com UNITED ARAB MARITRONICS TRADING L L C Tel 971 4 3247500 EMIR
40. ne bottle 0 43l FFKM assy 10374 30293 6 1 1120 Pump Zephal 23 10379 Speciality TS 98113 7 1 0 0 Sachet PEBD 90x75 50335 8 1 0 0 Hexagon key 1 3mm Steel 50350 ISO2936 Sam pler GTX Chem ND 20336 9 1 6640 0 Carrying case S2GT Wood 50338 30338 35m REF ND 10 1 0 1 Label Sampler 50005 40344 3 11 1 0 1 Label U S Patent 5408890 50055 41107 This drawing is our property and must not without our 4 57 Fabel Enrat Tanksystem 500087540343 eut be co sel sie available to others E nraf Tanksystem SA 13 1 14 4 Identification plate TS 10086 SX nnnn 1 4301 50089 41316 P eee P N 7 RUE DE L INDUSTRIE 2 CH 1630 BULLE 14 2 0 1 Round head grooved pin 1 4x4 A2 40760 DIN1476 The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 COUPE A A re Dn LIS A Hh 9 ax CZ SZ SN ee I YES 20 COUPE B B ATEX Certified Product No modifications permit ted without the approval ofthe authorised person
41. oduct No modifications permit ted without the approval of the authorised person i s eo 4 N l i COUPE A A B z 1 MRO 9 Wo f mi ED A f PUTEM i 2 o9 Pe Ta T B 801 TOLERANCES UNLESS OTHERWISE SPECIFIED Weight Norm Size Over 6 30 100 300 1000 k Item Gty Weight Description Material TS ND ri re 3 30 100 305 toon 2000 Antes 12278 1 Eff ISSUE 1 10 08 09 1 1 2173 4 Storage tube assy 20148 30610 Fine oos 01 015 02 03 os ot MPSA 2 1 24512 Carter winder FFKM assy 35m 98112A 20330 REMOVE ALL BURRS AND SHARP EDGES YYYN E 3 T 19 O Ring 25674x3 53 FFKM 20538 Bas Coni 1 2 memes apace by 4 1 13 4 Kit pump connector FFKM 20611 41021 CPI 10 08 2009 ND ND 5 1 983 4 Zo
42. rew M4x6 A2 40862 DIN 914 12 1 77 9 Load 1 4401 20127 40964 13 1 3 0 Slotted pan head mach screw M4x25 A2 40703 ISO1580 14 1 8 5Clip 1 4301 20129 40965 TOLERANCES UNLESS OTHERWISE SPECIFIED Weight Norm Size Over 6 30 100 300 1000 Fit Te e 30 100 300 1000 2000 9 5 1170 8 Eff ISSUE 1 05 09 2008 Fine t 0 05 0 1 0 15 02 03 05 0 1 MPSA REMOVE ALL BURRS AND SHARP EDGES YYYN Drawn Control 1 D 1 Replacement for Replaced by UPR 05 09 2008 ND ND Sampler 2 GTN Chem Bottom bottle 0 401 FFKM assy T TS 20132 ND 20247 REF ND This drawing is our property and must not without our E nraf Tanksystem SA RUE DE L INDUSTRIE 2 CH 1630 BULLE permission be copied or made available to others The receiver is responsible for every misuse Tel 41 26 91 91 500 Fax 41 26 91 91 505 ATEX Certified Product No modifications permit ted without the approval of the authorised person e lt 4 As eco T WZ atl a S Ue ZZ IL sc IL iet ie rou NT ERES LLL ear rr IY RRR KERR CORR Le ES K 489 LLS iz Lu x A7 UU 7 1 em NAET E AEE BEY AEEY AE E A SA A SS A A SY A A A A a ea rc cr A AD Br Noreen S077 7 5 Upper valve 1 O Ring 26 75x1 78 0 Hex nut M5 5 Spot cover PTFE 25 car Socket set screw M4x6 A2 Load 1 4401 Rod 1 4401 Bottle
43. s t a300 er Sn Description Material 4 j Eine 10 0 0 1105 02 10 3 10 5 01 MPSA E gt Body 2 female REMOVE ALL BURRS AND SHARP EDGES 4110 Seat 2 53 66 x 6 s Drawn Control 1 X Replacement for Replaced by Stem packing 2 17 23 9 x 8 5 2pces UPR 21 04 1994 ND ND Gland Nut Valves TS 10076 TE BETS HERMetic Compact Valve C2SS Nb 30391 j Fenole 4436 Handle 316 This drawing is our property and must not without our En r af Tanksys t em SA End cap Ball 2 permission be copied or made available to others The receiver is responsible for every misuse TE HT z UMS tas mid Pri Stem Gasket 86 90 x 2 5 Gasket 17 19 x 1 Washer for cable on yalve z Uu yv i 2 xmpII IS U i N FIZZ ING ZZZzzz SSSA SS SS SESS BER if ue S a Weight Description Security cover w lock 10408 40495 TOLERANCES UNLESS OTHERWISE SPECIFIED SSUE 3 25 6 1 999 Over 30 100 300 1000 s Hom men _ _ _ He 2000 totes 4746 Eff n Description Material y 1 Fine t 0 05 0 1 0 15 0 2 0 3 0 5 0 1 MPSA Body 2 female REMOVE ALL BURRS AND SHARP EDGES 4110 Seat 53 66 x 6 s Drawn Control 1 2 Replacement for Replaced by Stem packing 2 17 23 9 x 8 5 2pces UPR 21 04 1994 ND ND Gland Nut i TS 10078 51304 PE ND 30374 2 Fenale 4436 Spring washer 316 This drawing is our property an
44. soda for instance Store the instrument in a dry location 50442 SGTX 1305 12 HERMetic Sampler GTX Chem Honeywell 6 2 Operating the ZONE SAMPLING BOTTLE 80203 10374 Zone bottle 0 43 I FFKM assy Install the HERMetic Sampler GTX Chem with the sampling bottle on top of the HERMetic 2 ball valve by means of the quick connect coupling In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge the Sampler after it has been installed on the HERMetic 2 ball valve but before opening it Check that the HERMetic 2 ball valve is closed Open the transfer valve Install an inert gas bottle to the pump connector The inert gas pressure shall not exceed 0 3 bar Apply the inert gas through the pump connector to purge the HERMetic Sampler 1 1 1 1 1 5 After purging close the transfer valve akon Prepare the hose connection from the transfer valve to the laboratory bottle Check that its capacity is at least 0 5 l Open the HERMetic 2 ball valve Lower the bottle at a speed of at least 0 5 m sec If the lowering speed is too low the liquid will not flow through the bottle as the resistance of the ball to flowing needs to be higher than the its weight to keep open the bottom of the container Stop the bottle at the level where the sample is to be taken Lift the bottle back into the HERMetic Sampler housing turn the crank until getting a catc
45. t of any excess of liquid after use Remove the carter winder and clean the storage tube This cleaning must be done very properly in particular when corrosive liquids are sampled such as strong acids or caustic soda for instance Store the instrument in a dry location Check periodically whether the general state of the device is still OK Check periodically whether all the sealings are still OK Check periodically the gas tightness of the unit up to 0 3 bars with an appropriate leak detector Check the tape wiper for wear If necessary tighten it with the hexagonal key 1 3 mm Clean periodically the sampling bottle Check the valves of sampling bottles for liquid leakage Check periodically the tape for kinks Check periodically the bearings state Bearings have limited lifespan Check periodically at least every 6 months the continuity of grounding by measuring the electrical resistance between the hook lock or the sampling bottle and the quick connect coupler Resistance should not exceed 100 Q 50442 SGTX 1305 17 HERMetic Sampler GTX Chem Honeywell 7 3 Sampler cleaning It is required to fit the cleanliness level with the sample goals Where appropriate dismantle the sampler and clean the parts with an appropriate cleaner to prevent any contamination of the sample by the sampler itself 7 3 1 Carter winder To clean HERMetic Sampler carter winder can be easily removed as well and sampling bottle detached from tape
46. ths after installation but max 18 months after delivery ex works The Vendor undertakes to remedy any defect resulting from faulty design materials or workmanship The Vendor s obligation is limited to the repair or replacement of such defective parts by his own plant or one of his authorized service stations The Purchaser shall bear the cost and risk of transportation of defective parts and repaired parts supplied in replacement of such defective parts 50442 SGTX 1305 When returned to Enraf Tanksystem SA or any of its agreed Service Stations equipment must be contamination free If it is determined that the Purchasers equipment is contaminated it will be returned to the Purchaser at the Purchasers expense Contaminated equipment will not be repaired replaced or covered under any warranty until such time that the said equipment is decontaminated by the Purchaser The Purchaser shall notify by fax telex or in writing of any defect immediately upon discovery specifying the nature of the defect and or the extend of the damage caused thereby Where no other conditions have been negotiated between the Vendor and the Purchaser General Conditions 188 of United Nations shall apply This equipment has been certified as non electrical equipment for potentially explosive atmospheres for only those classes or categories of hazardous areas stated on the instrument label bearing the mark of the applicable approval authority No
Download Pdf Manuals
Related Search
Related Contents
ManualV1.10 Zenoah BC4310FW Brush Cutter User Manual Elixir™ User Manual HYKE-T - Motorisation Plus here> Betriebsanleitung Guia de Configuração Wireless 取扱説明書 - ミツバサンコーワ Copyright © All rights reserved.
Failed to retrieve file