Home
        ACCESSORY DOWNWARD DEFLECTOR HOOD
         Contents
1. 6 598 5       5H0795780000    February  2015    INSTALLATION INSTRUCTIONS   30    60    and 90   downward deflector hoods  and vertical air deflector blades   Models HD HDB  HDS HDC PTP  PTC BTC       ACCESSORY DOWNWARD DEFLECTOR HOOD    VERTICAL AIR DEFLECTOR BLADES          A WARNING TABLE OF CONTENTS    Gas supply shall be shut off and the electrical power Instructions     Downward Deflector Hood  disconnected before proceeding with the conversion  Instructions     Vertical Air Deflector Blades  Failure to do so could result in fire  explosion  electrical   shock  or the unit starting suddenly resulting in injury     IMPORTANT      The use of this manual is specifically intended for a  qualified installation and service agency  All installation  and service of these kits must be performed by a       qualified installation and service agency      These instructions must also be used in conjunction  with the Installation and Service Manual originally  shipped with the appliance  in addition to any other  accompanying component supplier literature        THIS MANUAL IS THE PROPERTY OF THE OWNER   PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB     INSTALLATION     DOWNWARD DEFLECTOR HOOD    Deflector Hood Model Application      The 30    60   and 90    Downward Deflector Hoods are 2  Remove the screw on the right lower face of the unit    designed for use on propeller and blower unit heaters   when facing the unit air outlet  and attach the hood right  side p
2. ades from the unit heater on  which the vertical louvers are to be installed  This is to  allow working room for attaching the top and bottom  vertical louver brackets  These blades will be replaced  after the brackets are installed  To remove the spring  loaded louver blades  grasp the blade and apply  pressure against the blade retaining spring  After  compressing the spring  the tab on the opposite side of  the blade can be removed from the unit     Note  Do not lose the louver blade retaining springs as  they will be required later to reinstall the blades     2  Place one of the vertical louver mounting brackets on the  bottom edge of the unit discharge opening so that the  flanges of the bracket are facing down with one flange on  the inside edge of the bottom panel on the unit heater   see detailed view in Figure 4 2   Attach with  10 x 1      screws supplied with the kit     3  Repeat the process outlined in Step 2 for the top vertical  louver mounting bracket except note that the flanges of  the bracket should face upward  see Figure 4 2      4  Replace the two louvers removed from the unit heater in  Step 1  To install the spring loaded louver blades  place  the louver blade retaining spring over the left end tab of  the blade and guide the spring into the recessed dimple  in the left side panel of the heater  Apply pressure to  compress the spring and then insert the metal tab on the                 ma Win               at          _       opposite end of the blade 
3. anel onto the unit with unit screw previously    removed by screwing through the existing hole     3  Insert the hood top panel into the top of the unit air outlet  opening  hemmed edge toward the hood outlet  bent  edge toward the unit  with the right side panel on the  outside of hood right top flange  see Figure 2 1   Fasten  the panels with the  10 x 1     self drilling screws provided     4  Attach the hood top to the flange inside the air outlet of    Assembly Installation l a the unit with the  10 x 1     self drilling screws provided   The recommended procedure for assembly and installation is through the holes in the hood top     described as follows     Note  If the Downward Deflector Hood is being installed  on an existing unit that has a 2 Point Suspension  Kit installed  the Suspension Kit may need to be  adjusted  Refer to the 2 Point Suspension Kit  Installation Manual  6 567  for further instructions     5  Mount the left side hood panel to the hood top with the    1  Before beginning installation of the accessory hood  screws provided but do not fasten to the unit casing at  remove all of the spring loaded louver blades from the this time  Be sure to mount the left side on the outside of  unit heater on which the hood is to be installed  These the hood top flanges     blades  except for one  will be relocated in the face of the  hood assembly after the hood is attached to the unit  heater  To remove the spring loaded louver blades   grasp the blade and apply 
4. e in the left  side panel of the hood  Apply pressure to compress the  spring and then insert the metal tab on the opposite end  of the blade into the tab clearance holes in the right hand  side panel of the hood  Repeat this procedure for all of  the louver blades  see Figure 2 1   Rotate the blades in  the desired direction of air flow  Do not operate the unit  with the blades in the closed position       Attach the included warning label to the lower front of the    discharge hood     Install the screw hole filler plugs to all remaining open  exterior holes     6 598 5    INSTALLATION     VERTICAL DEFLECTOR BLADES    Vertical Deflector Blade Model Application Figure 4 1     Vertical Blades Exploded View    The Vertical Deflector Blades are designed for use with  propeller and blower unit heaters  Installation of the  assembly is easiest prior to unit installation     Assembly Installation   The following section contains the recommended procedure  for assembly and installation of the vertical louver blade  assembly  Note that model sizes 30 156 feature a single  bank of louvers  Due to the larger discharge opening area   model sizes 175 200 feature two louver banks and sizes 250   400 feature four louver banks  refer to Figure 4 3   Asa  result  the instructions below need to be repeated for each  louver bank on unit sizes 175 and larger     1  Before beginning installation of the accessory vertical  louver blade assembly  remove the top and bottom  spring loaded louver bl
5. embled  it is necessary  to connect two 30   sections together for a 60   hood  and  three 30   sections for a 90   hood  See Figure 2 2     a  For hoods with multiple sections  connect the  sections together by attaching the left and right side  panels to the front of the previous section using the  upper and middle mounting holes on the side plates  with  10 x 1     self drilling screws     b  Install the hood top between the side panels with the  hemmed edge toward the hood outlet  deflector  blades   Fasten with  10 x 1 2  self drilling screws  provided     c  Install two or more  10 x 1   2 self drilling screws  through the top panel of the first hood and into the  top of the second hood top panel where they over  lap  Locate the screws 5    in from each side of the  hood and 1     back from the seam of the two top  panels     d  For model sizes 30 156  one fixed blade is supplied  with each kit  Extra fixed blades should be  discarded and only the fixed louver blade from the  first 30   section kit be used  refer to Step 7        Place the louvers removed from the unit heater in Step 1    into the outlet of the downward deflector hood  For  model sizes 250 and 300  the deflector hood kit includes  one additional louver blade and louver retaining spring  that are to be installed into the outlet of the hood  To  install the spring loaded louver blades  place the louver  blade retaining spring over the left end tab of the blade  and guide the spring into the recessed dimpl
6. into the tab clearance holes in  4  Louver Banks  the right hand side panel of the heater  Rotate the on Size Sa 400  horizontal blades in the desired direction of air flow  Do   not operate unit with the blades in the closed position     5  Insert the vertical louver bracket support rod through the  holes provided in the mounting flanges  Secure this  support rod with the acorn push nuts provided    6  Install the vertical louver blades into the top and bottom  brackets  using the same process as outlined in Step 4    7  Adjust deflector blades to obtain desired direction of heat  throw  Do not operate the unit with the blades in the  closed position     iii ah         i  I N       Modine Manufacturing Company has a continuous product improvement program   and therefore reserves the right to change design and specifications without notice     Modine Manufacturing Company e 1500 DeKoven Avenue e Racine  Wisconsin  USA 53403 2552  Phone  1 800 828 4328  HEAT  e www modinehvac com     Modine Manufacturing Company 2015 6 598 5    
7. pressure against the louver  blade retaining spring  After compressing the spring  the  tab on the opposite side of the blade can be removed Figure 2 3     Cross Member  from the unit  freeing the blade from the unit     Note  Do not lose the louver blade retaining springs as  they will be required later to install the blades into  the hood assembly     6  Model sizes 350 and 400 require a horizontal deflector  blade bracket cross member be installed  This is shown  in Figure 2 3     Figure 2 1   Hood Exploded View    350 400 Units  Only    _ 31 25    Outside Edge to    Front View Outside Edge       7  In each hood assembly kit for model sizes 30 156 is a  fixed deflector louver blade with serrated tabs at each  end to accept fastening screws  see Figure 2 1   Install  the blade between the outermost hood sides in the  bottom deflector blade position and fasten in place with   8 x 1    screws provided through the holes in the sides of  the hood and tightening  Locate the blade with the  curved surface up and the rounded corners toward the  outlet of the hood  Rotate the deflector to direct the air  flow in the desired direction  typically perpendicular to the  hood outlet face        2 6 598 5    INSTALLATION     DOWNWARD DEFLECTOR HOOD    Fasten the lower corner of the left side hood to the unit  face with a self tapping screw  Ensure that the assembly  and opening are square and the dimension from the  outside edges matches Figure 2 3     If 60   or 90   hoods are being ass
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
取扱説明書 - SERENE HOUSE  Carrozzina elettronica B500  ROLINE Gigabit Ethernet PCI Adapter RA-1000T32  SERVICIO AGRÍCOLA Y GANADERO DIVISIÓN SEMILLAS  los proyectos hacen los objetos eternos, las modas los  Casio AQ164WD-1AV User's Manual    cImportant - CNET Content Solutions  3) 暗 渠 排 水 用 機 械  Cooper Lighting QCT-1775WH User's Manual    Copyright © All rights reserved. 