1. BIN LEVEL control knob to the OFF position Disconnect power and water to the unit Remove electrical control box cover and kick plate Remove existing bin drain tubing BE PREPARED FOR WATER TO DRAIN FROM BOTH THE STORAGE BIN AND DRAIN TUBING 2 Uncoil the 10 foot long discharge tubing and push one end completely onto the barbed discharge elbow of the pump and securely fasten it with the worm gear clamp See figure 1 Route the other end through the rear of the unit to a convenient drain location 3 Carefully slide the pump assembly into the base of the unit and fasten it to the base using two black snap fasteners pushing them through the holes in the bracket and the matching holes in the base of the unit Push white pre formed tube onto bin drain fitting and secure with one short tie wrap See figure 1 Bin Drain Fitting 0 Figure 1 Q Short Tie wrap Worm Gear Clamp i a P Discharge Hose ea Snap Fasteners o a FULLY ASSEMBLED PUMP DETAIL BLACK LOI I WHITE L02 c RED BIN LEVEL CONTROL 2 4 Unplug connector from power cord and connect pump harness to power cord and machine connector located near compressor 5 Restore power to the unit and with the ON OFF BIN LEVEL control still in the OFF position pour several quarts of water into the bin The drain pump should turn on and pump the water out of the bin perhaps cycling on and off several times during the process Pump cycling is norm
2. INSTRUCTIONS FOR DRAIN PUMP KIT DCE D Series ASSEMBLY INSTRUCTIONS Using the kit parts shown in the figure below mount the pump assembly P N 12 2503 21 sold separately to the bracket and assemble fittings hoses and electrical connector Two white pre formed hoses are included in the kit Use the hose with a straight end for old style bins having a tee fitting at the sump bin drain or use the hose with a formed elbow for current models having the sump drain routed inside the bin Note Before installing the discharge elbow onto the pump nipple visually inspect elbow for proper assembly of check valve and spring see detail A below Tighten the elbow so no more than two threads show and the elbow is pointing towards the REAR motor end of the assembly Electrical Discharge Elbow Connector White Pre Formed Long Tie Wrap Hose Chose 1 of 2 Discharge Elbow aN N PD NEG lt gt VS fa j O e Oo Ratchet Clamp Short Tie Wrap ch Sensing Tube ZY BLACK LOI WHITE L02 RED BIN LEVEL CONTROL Check Valve Spring lt e Detail A 17 3363 01 GRAVITY DRAIN CONVERSION INSTRUCTIONS Use these instructions to convert an existing gravity drain system to a pump drain system Unit must be completely accessible from the rear to complete the installation of discharge tubing If necessary remove the unit from it s built in location to provide full access 1 Set ON OFF
3. ITCH ao N y V4 RP p y SAFETY s m pan eae ae iT GN Y 2 1 y i IBIN E CUBE SIZE LEVEL BIN LeveL L i mii CONTROL y CONTROL CONTROL anor oo BK _ BU Q w BU Se os i W CUBE SIZE 9 icom JET N NI INITIATE Sy _ R HOT CAS FAN TIMER NO ee C Ss L SWITCH Aam Ne gt 6 PRESSURE i R VW BK 3 F NOTOR aca Ls fi emme R NO 1 WATER 2 row mge p ae sj TIMER 2 TIMER 2 mala R W WATER _ SOLENOID SOLENOID A W Z DRAIN RELAY CURRENT a PUMP 1 SOLENOID Se Gana a SWITCHES ON THIS UNIT oo SHOWN IN TIMED PORTION YS 42 OF THE FREEZE CYCLE 30 aa I L oo feozeessson WITH DRAIN PUMP IN OPERATION INSTALLATION INSTRUCTIONS 1 UNT MUST BE INSTALLED AND IN 3 ROVE 3 8 ID FLEXIBLE HOSE FROM LEFT FRONT OF M ACHINE 5 BY TURNING THE ON OFF SWITCH BIN LEVEL ACCORDANCE WITH LOCAL COES PER INSTRUCTIONS FOR DCE3PA IN SERVICE MANUAL CONTROL DIAL IN A CLOCKWISE DIRECTION 2 CONECT A POTABLE WATER LINE TO 1 4 NPT ON WATER 4 COWECT THE ELECTRICAL POWER CORD TO TO APPROXIMATE OPERATING RANGE MARKING 17 3353 01 VALE LOCATED IN HE FRONT ON TH MACHINE A PROPERLY WIRED AND CROWDED RKEPTICAL UNIT IS NOW IN AUTOMATIC OPERATION
4. al since the pump out rate of the drain pump is greater than the rate of drain through the bin 6 While the pump is discharging water THOROUGHLY CHECK THE ENTIRE DRAIN SYSTEM FOR LEAKS 7 Re install unit into built in or free standing location ENSURE THAT NO KINKS OCCUR IN WATER INLET OR DRAIN TUBING 8 Restore potable water supply and manually advance the unit s timer to the HARVEST position Turn the ON OFF BIN LEVEL control knob ON to the required operating range setting for the application Check unit for at least one cycle to ensure proper operation and to allow a final check for leaks of any kind 9 Re install control box cover and kick plate Conversion of a gravity drain system to a drain pump system is now complete IF DRAIN PUMP IF DRAIN PUMP S IS INSTALLED IS INSTALLED COMM R i 5 POWER IN BK J 1 NO are EARTH GROUND l DRAIN PUMP SAFETY GN Y ie PRESSURE BK PRESSURE 4 Zl SWITCH DRAIN SW

Download Pdf Manuals

image

Related Search

Related Contents

セットアップ ガイド  User Manual Danfoss Online  CMAX™ 28ST, 34ST BA 750ST, 750C, 850ST I  IronMail 6.5.1 E-Class Setup Guide  Radio Cassette  (クリーンキューム ® Wシリーズ)PDFカタログ  User Manual - Bodytronics  Page 1 Page 2 Page 3 « A tous les scribes et artistes pratiquants de  Citizen CH-485E User's Manual  OPERATING INSTRUCTIONS - RAYTECH  

Copyright © All rights reserved.
Failed to retrieve file