1. CSA INTERNATIONAL Certificate of Compliance Certificate 2328979 Master Contract 229815 Project 2447463 Date Issued August 16 2011 Issued to Sennheiser electronic GmbH amp Co KG Product Engineering ENP Am Labor 1 Wedemark 30900 Germany Attention Mr Volker Bartsch The products listed below are eligible to bear the CSA Mark shown with adjacent indicators C and US for Canada and US or with adjacent indicator US for US only or without either indicator for Canada only Sam Taw Issued by Sam Tam C US PRODUCTS CLASS 2226 51 AUDIO AND VIDEO EQUIPMENT Commercial Audio Equipment CLASS 2226 81 AUDIO AND VIDEO EQUIPMENT Commercial Audio Equipment Certified to US Standards PART A Conference system consisting of center unit model ADN CU1 rated 100 240V 50 60Hz 245W cord connected class I grounded and consoles ADN D1 for delegates and ADN C1 for chairmen rated 52 8Vdc 1 75A powered by center unit PART B Conference system model ADN PS US rated 100 240V 50 60Hz 385W cord connected class I grounded APPLICABLE REQUIREMENTS CAN CSA C22 2 No 60065 03 Incl AM1 Audio Video and Similar Electronic Apparatus Safety Requirements UL Std No 60065 2007 Audio Video and Similar Electronic Apparatus Safety Requirements DQD 507 Rev 2009 09 01 CSA INTERNATIONAL Supplement to Certificate of Comp
2. alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product 3 WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE AND OBJECTS FILLED WITH LIQUIDS SUCH AS VASES SHOULD NOT BE PLACED ON THIS APPARATUS or equiv DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 3 PROJECT 2447463 Date Issued August 16 2011 4 TO COMPLETELY DISCONNECT THIS APPARATUS FROM THE AC MAINS DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE AC RECEPTACLE or equiv 5 THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY ACCESSIBLE or equiv b Optional as needed Verbatim for the US if applicable Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug
3. 11 across both diodes and possible abnormal charging current to 2 6mA if battery is fully discharged to OV and 12V supply is shorted directly to R76 which requires multiple faults to occur Marked in Service Manual CAUTION DANGER OF EXPLOSION IF INCORRECTLY REPLACED or Adjacent to the Battery REPLACE ONLY WITH SAME OR EQUIVALENT TYPE External Power Out Connections Type Two ports for providing power to consoles Adjacent Markings 2 x 52 8Vdc 1 75A dc symbol is used in place of dc Note USB outputs were tested with worst case loading DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 8 PROJECT 2447463 Date Issued August 16 2011 PARTB ADN PS US General The subject device is a conference system used same certified power supply in PART A Weight of Equipment 4 3 kg Pollution Degree 2 Insulation Material Group IIIb Maximum Rated Ambient Temperature 35 C Circuit AC Line Coupling Inductive through an isolating switch mode transformer Enclosure Tabletop style combustion resistant Secured together by screws Overall Dimensions Approx 190mm D by 420 mm W by 100 mm H with feets General Construction Rating Part Material Thickness Manufacturer Type Thickness Top sides Painted sheet steel 1 3 mm Bottom rear and Sheet steel 1 3 mm inner left and right sides and inner front
4. A Accepted for commercial equipment or moulded or silk screened onto the enclosure CSA Nameplate LR 113693 MH18055 Manufacturer BDF AG Type CSA 0 15 Type B Label Stock Tesa 6930 for use indoor and outdoor on plastic or metal Material Matte Black Acrylate Label Stock with laser printing Laser Printer DPL Nexus Marker by ACI Laser Note Bilingual Markings for products with CSA Mark Jurisdictions in Canada may require these markings to be also in French It is the responsibility of the manufacturer to provide bilingual marking where applicable in accordance with the requirements of the Provincial Regulatory Authorities It is the responsibility of the manufacturer to determine this requirement and have bilingual wording added to the products Additional Markings Factory identification more than 1 factory Owner s Manual a Mandatory 1 Heading IMPORTANT SAFETY INSTRUCTIONS before operating instructions 2 Explanation of graphical symbols Lightning Flash and Exclamation Mark Fig 19 DU as follows or equivalent a Lightning Flash Symbol with The Lightning Flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons b Exclamation Point Symbol with The exclamation point within an equilateral triangle is intended to
5. C V 2 inlet EMI filter and on chassis earth male spade tab Insulated spade connectors on mains JST PS187 250V 25A 105C V 0 switch SMPS mains input connector CN1 JST VH 10A 250Vac de V 0 female 85C Note Plastic parts of this connector are not relied upon for contact Routing Sleeving of Wiring Primary wiring is sleeved to prevent contact with power supply secondary components Secondary wiring from SMPS output is dressed away from power supply and fans with wire ties that are adhesively secured to the inner bottom enclosure This is considered good workmanship and not critical for safety as there would be no hazard should the wiring become detached if the adhesive let go The adhesive is therefore considered not safety critical and is therefore not controlled in this report All other wiring is secondary and is short enough to not come in contact with bare primary parts or excessive temperatures Insulating Barrier Sleeving See critical components list Lithium Battery Evaluated UR Type Service replaceable only Manufacturer Energy One Electronics OmniCel MH47566 Cat No CR2032 Rating 3 0V 0 20mA nominal discharge current 200mAh 5 0V max charging voltage Mounting In PCB mounted battery clip Battery Isolation Circuitry R76 4 7kQ and D11 BATS54C R76 limits possible discharge current to 0 64mA requires fully charged battery and S C of D
6. Hz 385W cord connected class I grounded APPLICABLE REQUIREMENTS CAN CSA C22 2 No 60065 03 Incl AM1 Audio Video and Similar Electronic Apparatus Safety Requirements UL Std No 60065 2007 Audio Video and Similar Electronic Apparatus Safety Requirements This report shall not be reproduced except in full without the approval of CSA International Telephone 416 747 4000 1 800 463 6727 Fax 416 747 4149 www csa international org DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 2 PROJECT 2447463 Date Issued August 16 2011 MARKINGS Markings as given below and or described in the report appear on each unit Submittor s name or Master Contract No 229815 Model designation Electrical rating in volts hertz amperes or watts Period of manufacture date code S N 3 mo min period CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR together with the two graphical symbols a lightning flash with arrow point within an equilateral triangle and an exclamation point within an equilateral triangle appears on the removable cover to gain access The product may bear one of the following CSA markings CSA or CSA us or cCSAus Other covers Lightning Flash in triangle symbol Method A CSA Mark or a CSA Mark with the C US or NRTL C or US or NRTL indicator and other required information appears on a durable adhesive nameplate CS
7. TL C CSA Certified to CSA US requirements US or NRTL CSA Certified to US requirements UL UL Listed equipment sub system cUL UL Listed equipment sub system to CSA requirements UR UL Recognized component sub system cUR UL Recognized component sub system to CSA requirements A SAA B BSI CEB CEBEC D DEMKO FI FIMKO I IMQ K KEMA N F NEMKO O OVE S z SEMKO S SEV T TUV V VDE Note An asterisk following the Approval Code denotes a component marked with the Agency s approval mark as applicable PARTA ADN CUI ADN D for delegates and ADN C1 for chairmen General The subject device is a conference system consisting of a center unit that includes a power supply that powers the center unit itself and also consoles with microphones for use by chairmen ADN C1 and delegates ADN D1 The consoles for chairmen and delegates are identical except for upper shell the mesh cover the key insert and console ADN C1 has two additional keys Both ADN Cl and ADN D1 use the same printed circuit board Weight of Equipment 6 5kg Pollution Degree 2 Insulation Material Group HIb Maximum Rated Ambient Temperature 35 C Circuit AC Line Coupling Inductive through an isolating switch mode transformer Enclosure Center unit Table or Rack mount style combustion resistant Secured together by screws Consoles Tabletop style combustible Secured together by screws Over
8. Type Material Fasteners Mounting Instructions L shaped rack 2 5mm thick painted T25 Torx Provided User is instructed to remove specific screws mount ears sheet steel head screws and to use these screws to secure brackets Note For dimensions see Att 2 Ventilation Openings See attached photos Critical openings described below Location Dimensions mm Front panel 2 7mm holes covering an area approximately 35mm by 157mm Bottom 2 9mm holes covering an area approximately 39mm by 194mm Bonding The power supply cordset terminates at an appliance inlet EMI filter module A min No 18AWG 150mm long green or green yellow insulated bonding conductor joins the rear of the inlet EMI filter module to the chassis A female insulated spade connector connected to the male earth spade connector on the rear of the inlet EMI filter module is double crimped to the bonding wire The other end terminates singly with a double crimped female spade connector connected to a male spade connector that is cold welded to the chassis The IEC 417 5019 symbol is marked adjacent to the earth spade terminal on the chassis DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 7 PROJECT 2447463 Date Issued August 16 2011 Connectors INT Certified UR Evaluated V 2 min Location Manufacturer Cat No Rating Flame Rating Insulated spade connectors on rear of Stocko EH649 130
9. all Dimensions Center unit Approx 345mm D by 416 mm W by 87 mm H plus rubber feet approx 12mm high Consoles Approx 140mm D by 180mm W by 55mm H plus microphone approx 400mm high depending on bending of flexible microphone neck DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 6 PROJECT 2447463 Date Issued August 16 2011 General Construction Rating Part Material Thickness Manufacturer Type Thickness Center unit top and Painted sheet 1 1mm left and right outer steel sides Center unit outer Painted sheet 2 1mm front panel steel Center unit bottom Plated sheet steel 1 0mm rear and inner left and right sides and inner front Center unit LCD Polycarbonate 1 5mm Sabic Innovative 241 f V 0 0 75mm display window designated Plastics B V E45329 241R f2 Lexan or ML3491 For materials used in the construction of the consoles refer to the critical components list Adhesives Adhesives are used as part of a wire tie to secure secondary wire from SMPS to parts of the enclosure and neatly route the wire to the main secondary PCB This is considered good workmanship and not critical for safety as there would be no hazard should the wiring become detached if the adhesive let go The adhesive is therefore considered not safety critical and is therefore not controlled in this report Rack Mount Bracket
10. does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped COSCON i NO ALTERATIONS 1 Markings as detailed above 2 The power supply cord set described in the critical components list in this report is provided with the product FACTORY TESTS a Basic Dielectric The equipment at the conclusion of manufacture before shipment shall withstand for one sec without breakdown the application of a Nominal 120V 800V ac or 1130V dc b Nominal 240V 1500V ac or 2120V dc between live parts and exposed non current carrying metal parts The factory test may be made at existing room temperature The product factory tests shall not exceed 2000V ac Each transformer connected to the ac supply shall be subjected to the following dielectric strength test
11. ed above is identical to model ZWS240PAF see attached list of critical components Additional evaluation was conducted Att 3 except for the components detailed in this critical components list as necessary SMT within Densei Lambda CA72462 thermal class IEC60065 clause tested with PSU T1 155 C F 14 3 appliance Fan over COOLTRON FD8015B12W1 DC 12V 1 8W_ CSA 113 cURus E194726 SMPS and rea 82 UL 507 TUV enclosure insulation foil Bayer Makrofol FR y thickness V 0 tested with around SMPS 0 25 mm appliance UR E118859 Modular Jack Tyco AMP 6116522 1 DC 60 V 1 75A_ IEC 60065 cl Tested with RJ45 double 70 C 17 5 EN 61984 appliance type Following for PART A only System cable ELKA SDC CBL RJ45 AC 125 V 60 C CSA 210 UR E336118 International CAT 5 Line 24 AWG UL 758 Cord with RJ45 DQD 507 10 Rev 2011 03 25 Plug 10P10C MASTER CONTRACT 229815 REPORT 2328979 Page No 12 PROJECT 2447463 Date Issued August 16 2011 Component Manufacturer Type Model Value rating Standard Approval Trademark Reference Prim Cable Kahlig VW 1 AWGI8 JST connectors CSA 210 cURus switch to sw style solid white UL 758 E223795 PCB AWG18 1007 1569 JST colour E60389 180 SPS 51T 187 8 4 8x0 8 E60389 Drawing SVH 21T P1 1 3 2mm sw E60389 534842 SVH AWG 22 18 9 0mm 3 0mm E204071 Engler heat Sw E48762 shrink Thu
12. f actuation V 0 Prim Cable Kahlig VW 1 AWG18 JST connectors CSA 210 cURus plug to switch 310 solid white UL 758 E223795 AWG18 310 bl style colour Stocko E223795 Drawing 1007 1569 br connectors E60389 516464 style 1007 1569 transparent E204071 JST SPS 51T colour E204071 187 8 4 8x0 8 Engler heat 3 2mm sw shrink 9 5mm sw Engler heat shrink DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 11 PROJECT 2447463 Date Issued August 16 2011 Component Manufacturer Type Model Value rating Standard Approval Trademark Reference Prim Cable Kahlig VW 1 AWG18 Stocko CSA 210 cURus Protective 150 connectors UL 758 E223795 earth cable gn ye style transparent between AC 1007 1569 colour inlet to chassis AWG18 150 Drawing 516468 Connector JST PS187 250V 25A UL94V 0 CSA LR20812 Insulation of 105 C CSA 182 3 UR E60389 quick connector solid white UL 1977 colour Connector Tyco 5 160432 4 28A 105 C CSA 182 3 CSA LR7189 metal part UL 1977 UR 66717 Insulation of Stocko EH649 min 130 C min UL94V 2 UR E172855 quick connector transparent colour PVC Tubing Polycons 810006005 6x0 5mm sw CSA 198 UR E245346 sleeved on UL 224 primary leads PSU TDK Lambda ZWS240PAF input IEC60065 A1 JPTUV 024689 48 JSE 100 240V UR E122103 50 60HZ 3 5 A re evaluated as output 52 8 V part of the 45A appliance Note The power supply list
13. female spade connector connected to a male spade connector that is cold welded to the chassis The IEC 417 5019 symbol is marked adjacent to the earth spade terminal on the chassis Connectors INT Certified UR Evaluated V 2 min Location Manufacturer Cat No Rating Flame Rating Insulated spade connectors on rear of Stocko EH649 130C V 2 inlet EMI filter and on chassis earth male spade tab transparent colour Insulated spade connectors on mains JST PS187 250V 25A V 0 switch solid white colour 105C SMPS mains input connector CN1 JST VHR 5N 10A V 0 female solid white colour ae de Note Plastic parts of this connector are not relied upon for contact Insulated spade connectors on Stocko EH649 130C V 2 Primary relay transparent colour Routing Sleeving of Wiring Primary wiring is sleeved to prevent contact with power supply secondary components Secondary wiring from SMPS output is dressed away from power supply and fans with wire ties that are adhesively secured to the inner bottom enclosure This is considered good workmanship and not critical for safety as there would be no hazard should the wiring become detached if the adhesive let go The adhesive is therefore considered not safety critical and is therefore not controlled in this report All other wiring is secondary and is short enough to not come in contact with bare primary parts or excessive temperat
14. lesius heat shrink Sec Cable Kahlig VW 1 AWG20 CSA 210 UR E223795 AWG20 530 rd style UL 758 E29179 534841 1007 1569 sw E60389 style 1007 1569 Molex 39 01 2025 5557 02R 210 39 00 0038 5559 T AWG 22 18 JST VHR 8N SVH 21T P1 1 SVH AWG 22 18 Sec Cable Kahlig VW 1 AWG18 CSA 210 UR E223795 AWG16 120 sw style UL 758 E29179 534802 1007 1569 Molex 39 01 2025 5557 02R 210 39 00 0077 5556 AWGI6 Foam for Kureta GmbH K ZK CP 150 25x15x10 9mm V 0 tested with mechanical appliance fixing at heat sink D2 D3 Secondary fuse Littelfuse No 372 TRS 250 V5 0A IEC60127 3 VDE licences in main unit 372150004xx CSA UL 248 14 116448 97187 cULus E67006 Poly switchin Tyco electric RKEF250 72 V 2 5 A CSA CA 3A CSA LR 78165 main unit IEC 60730 1 UL E74809 UL1434 T V Poly switchin Tyco electric SMD050 2 60 V 0 5A Tested with the main unit appliance LCD Display SABIC Polycarbonate min 1 5 mm IEC 60695 11 UR E45329 Window 241 241R f2 thick 130 C 10 ML3491 f transparent UL 94 rated V 2 DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 2328979 REPORT PROJECT 2447463 Page No 13 Date Issued August 16 2011 Component Manufacturer Type Model Value rating Standard Approval Trademark Reference PCB Material various FR4 V 0 min 120 C UL94 V 0 UR ZPMV2 Display switch board PCB Ma
15. liance Certificate 2328979 Master Contract 229815 The products listed including the latest revision described below are eligible to be marked in accordance with the referenced Certificate Product Certification History Project Date Description 2447463 August 16 2011 Addition of model ADN PS US 2328979 September 14 2010 Original Certification Descriptive Report and Test Results CSA INTERNATIONAL MASTER CONTRACT 229815 REPORT 2328979 PROJECT 2447463 Edition 1 September 14 2010 Project 2328979 Toronto Issued by David Briere P Eng Edition 2 August 16 2011 Project 2447463 Toronto Issued by Sam Tam Report pages reissued Addition of Photo 8 to 24 Contents Certificate of Compliance Page 1 Supplement to Certificate of Compliance Page 1 Description and Tests Pages 1 to 14 Photographs 1 to 24 Attachment 1 VDE CB report DE1 42864 M1 A1 Attachment 2 VDE CB report DE1 48159 PRODUCTS CLASS 2226 51 AUDIO AND VIDEO EQUIPMENT Commercial Audio Equipment CLASS 2226 81 AUDIO AND VIDEO EQUIPMENT Commercial Audio Equipment CERTIFIED TO U S STANDARDS PART A Conference system consisting of center unit model ADN CU1 rated 100 240V 50 60Hz 245W cord connected class I grounded and consoles ADN D1 for delegates and ADN C1 for chairmen rated 52 8Vdc 1 75A powered by center unit PART B Conference system model ADN PS US rated 100 240V 50 60
16. ly components that are eligible for substitution at the factory d Substitution of a CSA Certified component with a component Certified or Listed by another organization may result in annual sample pickup and Conformity Testing e Substitution of a Certified or Listed component with a component that is Recognized or Accepted is not permitted without evaluation and report updating COMPONENT SPECIAL PICKUP None DESCRIPTION Notes 1 The term INT following the component name denotes a certified component that can be replaced by another CSA Certified component or one from another certified source approved by OSHA SCC accredited body for the same application provided that it has an equivalent rating configuration size orientation mounting and that applicable minimum creepage and clearance distances are maintained from live parts to bonded metal parts and secondary parts 2 The term CT following the component name denotes a component that is subject to periodic re testing unless evidence of re testing equivalent to the CSA program is available 3 This report is supplemented by the attached IEC 60065 checklist DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 5 PROJECT 2447463 Date Issued August 16 2011 4 Approval codes all components are suitable for the application CorCa CSA Certified C US or NR
17. of the referenced report edition s Test data are kept in the Engineering Files at the CSA Toronto Office Project 2328979 Edition 1 All tests were conducted by VDE Tests marked with an asterisk were repeated at CSA International in Toronto for spot checking purposes The test of clause 13 was repeated only for working voltage from primary to secondary across the transformer gt VDE CB report DE1 42864 M1 A1 Project 2447463 Edition 2 Addition of model ADN PS US See attached VDE CB report DE1 48159 pr hehe VDE report DE1 48159 DQD 507 10 Rev 2011 03 25
18. outer front panel Painted sheet steel 2 3 mm For materials used in the construction of the consoles refer to the critical components list Adhesives Adhesives are used as part of a wire tie to secure secondary wire from SMPS to parts of the enclosure and neatly route the wire to the main secondary PCB This is considered good workmanship and not critical for safety as there would be no hazard should the wiring become detached if the adhesive let go The adhesive is therefore considered not safety critical and is therefore not controlled in this report Rack Mount Bracket N A Ventilation Openings See attached photos Critical openings described below Location Dimensions mm Front panel 2 6 mm dia holes covering an area approximately 150 mm by 33 mm Bottom 2 9 mm dia holes covering an area approximately 195 mm by 25 mm DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 9 PROJECT 2447463 Date Issued August 16 2011 Bonding The power supply cordset terminates at an appliance inlet EMI filter module A min No 18AWG 150mm long green or green yellow insulated bonding conductor joins the rear of the inlet EMI filter module to the chassis A female insulated spade connector connected to the male earth spade connector on the rear of the inlet EMI filter module is double crimped to the bonding wire The other end terminates singly with a double crimped
19. s for a period of one sec without breakdown An ac potential applied between each winding and the core and metal enclosure with all other windings grounded to the core and metal enclosure The test potential shall be DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 4 PROJECT 2447463 Date Issued August 16 2011 a For windings rated 30V and less 500V ac b For windings rated over 30V 800 1500V ac Note Transformer tests may be performed by the transformer manufacturer b Ground Continuity The equipment with protective grounding shall be tested as a routine production line test to determine that there is electrical continuity between the grounding pin of the attachment plug and the accessible dead metal parts of the equipment Alternatively a visual check may be made Warning The factory test s specified may present a hazard of injury to personnel and or property and should only be performed by persons knowledgeable of such hazards and under conditions designed to minimize the possibility of injury SPECIAL INSTRUCTIONS FOR FIELD SERVICES l Component Substitution a Critical components those identified by mfr name cat no are not eligible for substitution without evaluation and report updating b Component descriptions marked with the identifier CT are subject to annual pickup and Conformity Testing c Component descriptions marked with the identifier INT are the on
20. terial various FR4 V 0 min 120 C UL94 V 0 UR ZPMV2 Signal board PCB Material various FR4 V 0 min 120 C UL94 V 0 UR ZPMV2 IS ADN CU board PCB Material various FR4 V 0 min 120 C UL94 V 0 UR ZPMV2 ADN C1 DI1 ADN C1 DI1 various PA12 GF30 Terblend UL94 HB QMFZ2 E41871 Material of ABS PA enclosure Following for PART B only Primary Cable Kahlig VW 1 AWG18 JST connectors CSA 210 cURus set Switch to 150 solid white UL 758 E223795 relay and pcb colour E66717 Drawing E60389 534893 E204071 Relay Finder 66 series 30A 250A IEC EN 61810 1 VDE 40013190 66 82 9 024 000 Spacing re testing is between currently running the primary and with order secondary 8 mm 148466 Flammability IMQ classification cUL E81856 see certified for US burning test acc and Canada annex G on next page Secondary Tyco electric RKEF 250 72 V 2 5 A CSA CA 3A CSA LR 78165 polyswitches IEC 60730 1 UL E74809 Pos F1100 UL1434 TUV F1200 F1300 F1400 F1500 Base material various various Min V 1 UL94 UL of classified PCB Note A detailed list of components that were damaged during fault testing is maintained on file 1 an asterisk indicates a mark which assures the agreed level of surveillance DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 REPORT 2328979 Page No 14 PROJECT 2447463 Date Issued August 16 2011 TESTS The subject equipment was found to be in compliance with the following tests during the evaluation
21. ures Insulating Barrier Sleeving See critical components list Lithium Battery No battery External Power Out Connections None DQD 507 10 Rev 2011 03 25 MASTER CONTRACT 229815 2328979 REPORT PROJECT 2447463 Critical Components Note Page No 10 Date Issued August 16 2011 PART A The following critical components list was extracted from VDE CB report 580000 3330 0004 129760 and modified for corrections and clarity as necessary PART B The following critical components list was extracted from VDE CB report 580000 3330 0004 147417 and modified for corrections and clarity as necessary Component Manufacturer Trademark Type Model Value rating Standard Approval Reference Following for both PART A and B Power supply Shin Yang Connector SY 10A 125V CSA 21 42 CSA LR 105093 cord set Electric Elka 020 18AWG 182 3 UR E161496 Plug SY 050 UL 817 498 Line cord SJT 1977 EMC Schurter 5110 1033 1 250 Vac 10A EN133201 1994 ENEC 10 VDE Interference CSA 8 UL1283 cURus E72928 filter unit with integrated appliance inlet Mains switch Marquart 1858 1103 250Vac 5 100A IEC61058 ENEC 05 10 000 cycles IEC60065 clause KEMA Pollution degree 14 6 2124278 01 3 CSA 55 CSA contract 850C glow wire UL 1054 166260 project level 3 1544732 resistance to UR 41791 heat and fire Speed of making breaking is independent o