1. Pinpoint Triggering Provides the Most Flexible and Highest Performance Triggering with over 1400 Combinations to Address Virtually Any Triggering Situation Small Footprint and Light Weight Digital Phosphor Oscilloscopes DPO7000 Series Data Sheet m 12 1 Largest XGA Touch screen Display in the Industry Communications Mask Testing Clock Recovery from Serial Data Streams 64 bit NRZ Serial Pattern Trigger for Isolation of Pattern dependent Effects up to 1 25 Gb s NRZ Serial Test Pattern Triggering Low speed Serial Protocol Triggering I2C SPI RS 232 CAN Technology specific Software Solutions Provide Built in Domain Expertise for Ethernet USB 2 0 Compliance Testing Jitter Timing Eye Diagram Power DDR Memory bus analysis CAN and LIN Network Features amp Benefits Design 3 5 GHz Bandwidth Model for Serial and Digital Applications OpenChoice Software with Microsoft Windows XP OS Enables Built in 2 5GHz 1 GHz and 500 MHz Bandwidth Models for all Applications pe arige Mende Ana eo Up to 40 GS s Real time Sample Rate on One Channel and up to 10 GS s on All Four Channels Applications Up to 400 Megasamples Record Length with MultiView Zoom Feature Signal Integrity Jitter and Timing Analysis for Quick Navigation Verification Debug and Characterization of Sophisticated Designs gt 250 000 wims s Maximum Waveform Capture Rate Debugging and Compliance Testing of Serial Data Strea
2. Degrees radians group delay IRE and mV units Rectangular Hamming Hanning Kaiser Bessel Blackman Harris Gaussian Flattop2 Tek Exponential As an arbitrary math expression User definable filters Users specify a filter containing the coefficients of the filter Filter files provided A function that generates a Waveform Database pixmap from a sample waveform Sample count can be defined Window Functions Waveform Definition Filtering Functions Mask Function Display Characteristics Characteristic Display Type Display Size Display Resolution Waveform Styles Description Liquid crystal active matrix color display Diagonal 307 3 mm 12 1 in XGA 1240 horizontal x 768 vertical pixels Vectors Dots Variable Persistence Infinite Persistence Color Palettes Normal Green Gray Temperature Spectral and User defined Display Format YT XY 14 www tektronix com Computer System and Peripherals Characteristic Operating System CPU PC System Memory Hard Disk Drive CD R W Drive DVD Drive Mouse Keyboard Input Output Ports Port Front Panel Probe Compensator Output Recovered Clock for DPO7254 or DPO7354 only Recovered Data for DPO7254 or DPO7354 Description Windows XP Intel Pentium 4 3 4 GHz processor 2 GB Rear panel removable hard disk drive 80 GB capacity Front panel CD R W drive with CD creation software application Read only Optical wheel mouse USB interface Order 1
3. Sem us pen eT the need of an external down converter You get the functionality of a vector oe eb gia ne ne signal analyzer a spectrum analyzer and the powerful trigger capabilities I7i din Seon Lou Sam Goes narce of a digital oscilloscope all in a single package Whether your design ws validation needs include wideband radar high data rate satellite links or ma go i frequency hopping communications SignalVu vector signal analysis 007 at ae software can speed your time to insight by showing you time variant behavior of these wideband signals 101 56 dBm r Scale 1 37 us Position 0 000 s Scale 399 770 us SignalVu enables detailed analysis in multiple domains 10 www tektronix com Characteristics Vertical System Input Channels Bandwidth DSP Bandwidth Enhance Rise Time DSP Bandwidth Enhance Hardware Analog Bandwidth 3 dB Rise Time 10 to 90 typical Digital Phosphor Oscilloscopes DPO7000 Series DPO7054 DPO7104 DPO7254 DPO7354 4 n a n a n a 3 5 GHz 1 n a n a n a 115 ps 500 MHz 1 GHz 2 5 GHz 2 5 GHz 460 ps 300 ps 160 ps 145 ps 310 ps 200 ps 100 ps 95 ps Rise Time 20 to 80 typical DC Gain Accuracy Bandwidth Limits 1 with offset position set to 0 Depending on instrument model 3 0 GHz 2 5 GHz 2 GHz 1 GHz 500 MHz 250 MHz or 20 MHz Input Coupling AC DC GND 1 MQ 1 with 13 pF 2 pF or Input Impedance software selectable 50 Q 1
4. and power plug when ordering DPO7054 also includes 4 P6139A 500 MHz 10x passive probes Probes and accessories are not included in the oscilloscope warranty Refer to the data sheet for each probe for its unique warranty and calibration terms www tektronix com 15 Data Sheet Options Instrument Options Option Record Length Options Description Opt 2RL 80 MSamples max 20 MSamples ch Opt 5RL 200 MSamples max 50 MSamples ch DP07254 DPO7354 only Opt 10RL 5 400 MSamples max 100 MSamples ch DPO7104 DP07054 only Opt 2SR 2 Double maximum real time sample rate DPO7104 40 GS s 1 channel 20 GS s 2 channels 10 GS s 3 or 4 channels DPO7054 20 GS s 1 channel 10 GS s 2 channels 5 GS s 3 or 4 channels Software Options Opt DDRA 9 DDR Memory Bus Analysis Opt DJA DPOJET Jitter and Eye diagram Analysis Advanced Opt DJE DPOJET Jitter and Eye diagram Analysis Essentials Opt LSA Low speed Serial Analysis includes CAN LIN Trigger Decode and Analysis Opt MTM Mask Testing for Serial Communication Standards up to 1 5 Gb s Includes hardware clock recovery on DPO7254 DP07354 Opt LT Limit Testing Opt ASM Advanced Event Search and Mark Opt ET3 3 TDSET3 Ethernet Compliance Test Software Opt USB 4 TDSUSBS USB 2 0 Compliance Test Software only Opt UWBE8 Ultra Wideband Spectral Analysis Essentials Does not include WiMedia compliance tests Opt UWB 8 Ultra Wideband Spectral Analysis Software Includes WiMedia co
5. 015 432 000 000 015 736 000 Accelerating the research of specific events in an acquired waveform Limit Testing Opt LT This feature consists of comparing an acquired waveform to boundaries These boundaries are typically defined by the user to specify a tolerance band around a reference waveform If any part of the acquired waveform falls outside of the limit the software returns a failure message and the location of the failure is shown on the waveform Communications Mask Testing Opt MTM This feature provides a complete portfolio of masks for verifying compliance to serial communications standards It supports 156 Standards Masks ITU T 64 Kb s to 155 Mb s ANSI 11 102 1 544 Mb s to 155 Mb s Ethernet IEEE 902 3 ANSI X3 263 125 Mb s to 1 25 Gb s Sonet SDH 51 84 Mb s to 622 Mb s Fiber Channel 133 Mb s to 2 125 Gb s USB 12 Mb s to 480 Mb s IEEE 1394 491 5 Mb s to 1 966 Gb s Rapidl O up to 2 Gb s OIF Standards 1 244 Gb s Video 143 18 Mb s to 1 485 Gb s CAN and LIN Timing and Protocol Decode Software Opt LSA When you need to ensure seamless and reliable operation of a CAN or LIN network this option enables CAN bus triggering and provides the solution to measure oscillator tolerance propagation delay and simultaneously decode CAN and LIN messages with the protocol leveraging the trigger capabilities This option is offered on DPO7354 DPO7254 DPO7104 and DPO7
6. 1 MQ 1 mV div to 10 V div Input Sensitivity Vertical Resolution 50 Q 1 mV div to 1 V div 8 bit gt 11 bit with averaging 150 V CAT I derate at 20 dB decade to 9 Vrus above 200 kHz Max Input Voltage 1 MQ 5 Vrus with peaks less than 24 V Max Input Voltage 50 Q Position Range 5 divisions 1 mV div to 50 mV div 1 V Offset Range Offset Accuracy 50 5 mV div to 99 5 mV div 1 5 V 10 Divisions 100 mV div to 500 mV div 10 V 505 mV div to 995 mV div 15 V 10 Divisions 1 Vidiv to 5 V div 100 V 5 05 V div to 10 V div 150 V 10 Divisions 1 mV div to 9 95 mV div 0 2 offset value position 0 1 div 1 5 mV 10 mV div to 99 5 mV div 0 35 offset value position 0 1 div 1 5 mV 100 mV div to 1 V div 0 35 offset value position 0 1 div 15 mV 1 01 V div to 10 V div 0 25 offset value position 0 1 div 150 mV Delay between any two channels lt 100 ps 50 Q DC coupling and equal V div at or above 10 mV div typical Channel to channel Isolation Any Two Channels at Equal Vertical Scale Settings typical gt 100 1 at lt 100 MHz gt 30 1 between 100 MHz and 2 5 GHz gt 20 1 between 2 5 and 3 5 GHz 1 3 GHz for sine wave of more than 4 div amplitude typically Time Base System DPO7054 DPO7104 DPO7254 DPO7354 Time Base Range with Opt 2SR Time Resolution in ET IT mode with Opt 2SR 50 ps div to 1000 s div 25 ps div to 1000 s div 25 ps
7. DPO7UP with Opt RLO2 From standard configuration to Opt 2RL configuration RL05 From standard configuration to Opt SRL configuration RL010 5 On DPO7254 or DPO7354 from standard configuration to Opt 10RL configuration RL25 From Opt 2RL configuration to Opt 5RL configuration RL210 5 On DPO7254 or DPO7354 from Opt 2RL configuration to Opt 10RL configuration RL510 5 On DPO7254 or DPO7354 from Opt SRL configuration to Opt 10RL configuration To upgrade DPO7000 Series with DVI 8 Opt DVI RTE Opt RTE or TDSRT Eye software LSA Opt LSA 18 www tektronix com Option Description LT Opt LT ASM Opt ASM DDRA 9 Opt DDRA DJAM Opt DJA DJEM Opt DJE ET3 3 Opt ET3 USB 4 Opt USB UWBE 8 Opt UWBE UWB 8 Opt UWB MTM Opt MTM PWR Opt PWR SVEM Opt SVE SVP 10 Opt SVP SVM 10 Opt SVM Other Upgrades PTM s To upgrade DPO7254 or DPO7354 with Opt PTM CP2 7 TDSCPM2 ANSI ITU Telecom pulse compliance testing software requires Opt MTM on DPO7000 Series J2 TDSDDWM2 disk drive analysis software 2 DPO7054 and DPO7104 only 3 Requires Ethernet Test Fixture 4 Requires TDSUSBF USB Test Fixture Greater than 2 GHz bandwidth required for high speed USB 5 DPO7254 or DPO7354 only 6 Probe requires TPA BNC adapter 7 Requires Opt MTM 8 DPO7354 only 9 Requires DJA and ASM 10 Requires Opt SVE or SVEM CE e ISO 9001 Product s are manufactured in ISO registered facilities BY THE UTO COU
8. Internal DC Coupled 0 7 div DC to 50 MHz increasing to 1 2 div at rated analog bandwidth typical 2 5 div at 3 5 GHz with DSP Bandwidth enhance External Auxiliary Input 250 mV from DC to 50 MHz increasing to 350 mV at 1 MQ 290 MHz typical Trigger Characteristics A Event and Delayed B Edge Glitch Runt Width Transition Time Time out Event Trigger Types Pattern State Setup Hold Window all except Edge Pattern and State can be Logic State qualified by up to two channels I2C SPI and RS 232 standard CANbus available as Opt LSA Trigger on address data and special handshaking states and other conditions Auto Normal and Single User selectable it corrects the difference in timing between the trigger path and the acquired data path it supports all Pinpoint trigger types on both A and B Events except pattern trigger and not available in FastAcq Main Delayed by Time Delayed by Events Reset by Time Reset by State Reset by Transition All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time Communications related Requires Opt MTM Triggers Support for AMI HDB3 BnZS CMI MLT3 and NRZ encoded communications signals Select among isolated positive or negative one zero pulse form or eye patterns as applicable to the standard Serial Pattern Trigger On DPO7254 or DPO7354 only and requires Opt PTM Up to 64 bit serial word recognizer bi
9. Oscilloscopes DPO7000 Series Trigger Modes Mode Description Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC noise reject HF reject and LF reject Glitch Trigger on or reject glitches of positive negative or either polarity Minimum glitch width is down to 170 ps typical with rearm time of 250 ps for DPO7254 or DPO7354 Width Trigger on width of positive or negative pulse either within or out of selectable time limits down to 225 ps Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Event can be time or logic qualified Time out Trigger on an event which remains high low or either for a specified time period Selectable from 300 ps Transition Trigger on pulse edge rates that are faster or slower than specified Slope may be positive negative or either Setup Hold Trigger on violations of both setup time and hold time between clock and data present on any two input channels Pattern Trigger when pattern goes false or stays true for specified period of time Pattern AND OR NAND NOR specified for four input channels defined as high low or don t care State Any logical pattern of channels 1 2 3 clocked by edge on channel 4 Trigger on rising or falling clock edge Window Trigger on an event that enters or exits a window defined by two user adjustable thresholds Event can
10. as a touch screen shallow menu structures intuitive graphical icons knob per channel vertical controls support for right mouse clicks mouse wheel improvements saving of waveforms and measurements available in Preview mode Export Save Recall menu improvements Digital Phosphor Oscilloscopes DPO7000 Series Interoperability with Logic Analyzers for Digital Design and Debug Tektronix Integrated View iView data display enables digital designers to solve signal integrity challenges and effectively debug and verify their systems more quickly and easily This integration allows designers to view time correlated digital and analog data in the same display window and isolate the analog characteristics of the digital signals that are causing systems failures No user calibration is required And once set up the IView feature is completely automated More Insight into Your Complex Electrical Design for Characterization and Compliance Testing Such as a simple math expression waveform mask testing a pass fail compliance test event searching event marking or a custom application that you develop yourself the DPO7000 Series Oscilloscopes offer the industry s most comprehensive set of analysis and compliance tools A Wide Range of Built in Advanced Waveform Analysis Tools Waveform cursors make it easy to measure trace to trace timing characteristics while cursors that link between YT and XY display modes make it easy to i
11. be time or logic qualified Trigger Delay by Time 5 ns to 250 s Trigger Delay by Events 1 to 10 000 000 events Comm Provided as part of Opt MTM Support for AMI HDB3 BnZS CMI MLT3 and NRZ encoded signals Protocol trigger on DP07054 DPO7154 DPO7254 or DPO7354 I2C SPI and RS 232 CAN Protocol trigger on DP07054 DPO7154 DPO7254 or DPO7354 as part of Opt LSA Serial Pattern option Captures serial data stream with built in clock recovery PTM for NRZ standards up to 1 25 Gb s Extended with pattern lock triggering to capture repeated acquisitions of long serial test patterns Search and Mark Events Event Description Basic Mark any events and document waveforms Search positive negative slopes or both on any channels Event table summarizes all found events All events are time stamped in reference to trigger position Users can choose to stop acquisitions when an event is found Search glitches or runts as well as transition rate pulse width setup and hold time out window violations or find any logic or state pattern on any number of channels Search DDR read or write bursts with Opt DDRA Advanced www tektronix com 13 Data Sheet Waveform Measurements Measurement Description Automatic Measurements 53 of which 8 can be displayed on screen at any one time measurement statistics user definable reference levels measurement within gates isolating the specific occurrence within an acquisit
12. div to 1000 s div 7 50 ps div to 1000 s div 1 ps 500 fs 250 fs 500 fs 250 fs 7 5 ns to 250 s Time Base Delay Time Range sto 2808 Channel to channel Deskew Range 75 ns Delta Time Measurement Accuracy Trigger Jitter RMS 1 5 psrms typical with enhanced triggering OFF lt 100 fsrms with enhanced triggering ON Jitter Noise Floor Time Base Accuracy lt 1 psrms lt 2 ps peak for record duration lt 10 us typical lt 2 5 psrms for record duration lt 30 ms lt 65 parts trillion for record durations lt 10 s 2 5 ppm Aging lt 1 ppm per year www tektronix com 11 Data Sheet Acquisition System Real time Sample Rates 1 channel max with Opt 2SR 2 channels max with Opt 2SR 3 4 channels max with Opt 2SR Equivalent Time Sample Rate max Maximum Record Length per Channel with Standard Configuration with Record Length Opt 2RL with Record Length Opt 5RL with Record Length Opt 10RL DPO7054 DPO7104 DPO7254 DPO7354 10 GS s 20 GS s 40 GS s 20 GS s 40 GS s E 5 GS s 10 GS s 20 GS s 10 GS s 20 GS s a 2 5 GS s 5 GS s 10 GS s 5 GS s 10 GS s 4 TS s for repetitive signals 40 M 1 CH 20 M 2 CH 10 M 4 CH 80 M 1 CH 40 M 2 CH 20 M 4 CH 200 M 1 CH 100 M 2 CH 50 M 4 CH Maximum Duration at Highest Real Time Resolution 1 CH Resolution with Opt 2SR Max Duration with Standard Record with Opt 2SR Max Duration with Opt 2RL with Opt 2SR Max Duration w
13. 054 as Opt LSA Protocol Analysis 3 5 x Syne Scope to Selected Row Put Marker on Selected Row Set Zero Timestamp to Mito Controls Trig EE OOOO ODOR a Toos Save SensorWim Stuff BitWfm View atti onfigure Sorden MI 203 11ms M2 343 11ms AT 60 004ms M3 201 45ms M4 22095m AT sasems Ei CAH DW Protocol Analysis for Chi LIH Protocol Analysis for Ch2 al 9 23304ms Remor 12 12312 0 280 97ms_ DATAS ae 1218 0000 esaz0ms 1218 0000 ecosom 12 180000 eaveims izoa cessm 12 180000 10231m 1204 12080 106 51ms 12 180000 11236m 12180000 t105em 1218 0000 1207em 1218 0000 1249ems an dr me na mea dn a DATAS 1209 1203 0 28322ms DATAE 2304840 0 269 38ms DATAS 21 760040 0 307 51ms DATAS 2 12912 0 34256ms DATAS 0 s60 tims remor 0 222 80m REMOT 1209 120 0 283 11ms EXP 2 0Vidiv I c AEG Sous 500MSI s 2 0ns pt GTP 100mA div a Single Seq ET 1 36W S5 0ps 1 acqs RL 25 0k ee December 02 2005 DPOPWR xJ e Measurement Sources Select f Power Device Switching Loss M Chi I Ch2 Results Min Max Average Min Max Average _ f Ph 23 2mW 24 8mW 24 0mW 174nJ 186nJ 180nJ Report WI 362mW 370mW 365mW 2 71uJ 2 78uJ 2 74uJ SES NALA Avg Loss 421mW Avg Energy 3 16uJ Power Measur
14. 19 7083 00 for small keyboard fits in pouch USB interface and hub Description Front panel pins Amplitude 1 V 20 into a 250 Q load 500 mV from base to top into a 50 Q load frequency 1 kHz 5 BNC connector 1 25 Gb s Output swing 2130 mV into 50 Requires option to enable BNC connector 1 25 Gb s Output swing 200 mV into 50 Q Requires option to enable only USB 2 0 Port Aux Trigger Input Side Panel Parallel Port Audio Ports Keyboard Port Mouse Port USB Ports LAN Port Serial Port VGA Video Port Oscilloscope VGA Video Port Rear Panel Power Analog Signal Output Amplitude Bandwidth One USB 2 0 connector See Trigger specification IEEE 1284 DB 25 connector Miniature phone jacks PS 2 compatible PS 2 compatible Four USB 2 0 connectors RJ 45 connector supports 10Base T 100Base T and Gigabit Ethernet DB 9 COM1 port DB 15 female connector connect a second monitor to use dual monitor display mode Supports basic requirements of PC99 specifications DB 15 female connector 31 6 kHz sync EIA RS 343A compliant connect to show the oscilloscope display including live waveforms on an external monitor or projector 100 to 240 Vrms 10 47 to 63 Hz lt 550 W 115 Vrms 10 360 to 440 Hz CAT lt 500 VA BNC connector provides a buffered version of the signal that is attached to the Ch 3 input 50 mV div 20 into a 1 MQ load 25 mV div 20 into a 50 load 100 MHz i
15. Digital Phosphor Oscilloscopes DPO7000 Series Cables Cable GPIB Cable 1 m GPIB Cable 2 m RS 232 Cable Centronics Cable Accessories Accessory Mini Keyboard USB interface Keyboard USB interface Service Manual Instrumented DIMM for DDR3 Transit Case Video Display Clamp Order Rackmount Kit Front Hard drive Option for Rackmount Kit Removable HD Spare Oscilloscope Cart WaveStar Description Order 012 0991 01 Order 012 0991 00 Order 012 1298 00 Order 012 1214 00 Description Order 119 7083 00 Full size keyboard with 4 port USB hub Order 119 6297 00 Order 071 1740 xx Order scope NEXVu card for UDIMM Raw Card E Contact www nexustechnology com Order 016 1970 00 Order 013 0278 xx Order 016 1985 xx Order 0161979 xx Order 065 0744 xx Order K420 requires 407 5192 00 bracket set Windows application for remote access www tektronix com 17 Data Sheet Test Fixtures Fixture Description TDSUSBF Test fixture for use with Opt USB Probe Calibration Power Order 067 1686 xx Deskew Fixture Ethernet Test Fixture Order through Crescent Heart Software http www c h s com Adapters Adapter Description AMT75 1 GHz 75 Q adapter P6701B 6 Optical electrical converter multi mode P6703B 6 Optical electrical converter single mode Instrument Upgrades To upgrade your DPO7000 Series Oscilloscope order option as noted Option Description To upgrade record length
16. N FOR CERSACATON Digital Phosphor Oscilloscopes DPO7000 Series www tektronix com 19 Data Sheet www tektronix com Contact Tektronix ASEAN Australasia 65 6356 3900 Austria 41 52 675 3777 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 07 81 60166 Brazil 55 11 40669400 Canada 1 800 661 5625 Central East Europe Ukraine and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 33 0 1 69 86 81 81 Germany 49 221 94 77 400 Hong Kong 852 2585 6688 India 91 80 42922600 Italy 39 02 25086 1 Japan 81 3 6714 3010 Luxembourg 44 0 1344 392400 Mexico Central South America amp Caribbean 52 55 54247900 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 090 02 021797 Norway 800 16098 People s Republic of China 86 10 6235 1230 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 82 2 6917 5000 Russia amp CIS 7 495 7484900 South Africa 27 11 206 8360 Spain 34 901 988 054 Sweden 020 08 80371 Switzerland 41 52 675 3777 Taiwan 886 2 2722 9622 United Kingdom amp Ireland 44 0 1344 392400 USA 1 800 426 2200 For other areas contact Tektronix Inc at 1 503 627 7111 Updated 30 October 2008 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other
17. al time bandwidth than is possible with PSD fy band free en sytle spectrum analyzer based solutions Spectral Analysis and Digital Down i Conversion of RF data is fast and easy and the down converted frequency span of interest may be exported for further analysis in tools such as RSAVu ALE i and MATLAB UWB in addition adds With automatic packet TFC and data rate detection support for all band groups Time Frequency Codes and data rates WiMedia PHY 1 2 analysis provides a complete solution Rapid visualization debug and report generation of the Spectrograms Power Spectral Density QPSK DCM Constellations EVM vs Symbol Constellation Configure WFM File Packet Selection WiMedia Analysis Settings Next File f Band Group 1 Mj TFC Auto Data Rate Auto v radio1_bgitfc1bps480 wfm AE Gusto LT ADI 000 EI EVM vs Subcarrier Common Phase Error vs Symbol and Voltage vs Time _ plots and complete measurements are captured and documented for each IOIEN Ic test condition SignalVu Vector Signal Analysis Opt SVE SVP SVM Easily UWB WiMedia analysis and measurements validate wideband designs and characterize wideband spectral events ea EEIE peer By combining the signal analysis engine of the RSA6100A Real Time so er Spectrum Analyzer with that of the industry s widest bandwidth digital ign amen ima ee mou sodi oscilloscopes you can now evaluate complex signals up to 20 GHz without Ze
18. andard feature and includes Start condition Missing Acknowledge Restart Data Read Address and or Data Frame in a 10 bit or 7 bit format with a specific selection to choose whether or not to include the R W bit Digital Phosphor Oscilloscopes DPO7000 Series File Edit Vertical Horiz Seq Trig Display Cursor Measure Mask Math MyScope Analyze Utilities Help B j j j j j j U j j j T j j j j T T j j T j a 200mV div 10 0ns 10 0GS s 100ps pt GTP 200mV div Sample 1 261 acqs September 12 2005 Trigger Setup Hold A Setup Hold Acquire A Event E A Event Trigger Type Source Setup Time Trigger if Y v Setup Hold Ch 1 Ck n 1 58ns topo Data Level Ck Re dazi E ee dan x cas _300ps Clock Source a Settings Ch2 v Clock Edge Shared v Clock Level era 200mV File Edit Vertical U T T Jungs PAAR VI lot etd Andie WIR ita A n SI VERO REN DD REGIS e Ta seal 20 0us 5 0MS s 200ns pt Sample 6 940 acqs September 12 2005 Atvent Trigger Type e a Special Address Address Value Data Direction c z CE T Address None z o1 ae Either X Data Threshold Binary _ 1 2V elec Hex Clock Source mn Include R W Ch 2 v 4 V pa in address sce T I i Clock Threshold Start Address RW Ack Data Ack Stop 1 2V Condition zond Easily trigger on a specific 12C address SPI Serial Peri
19. astAcq acquisition mode Accelerate the Debug of Complex Electrical Designs FastAcq Acquisition Mode Expedites Debugging by Clearly Showing Imperfections More than just color grading FastAcq enabled by Tektronix proprietary DPX acquisition technology captures signals up to more than 250 000 waveforms per second on all 4 channels simultaneously dramatically increasing the probability of discovering infrequent fault events And with a simple turn of the intensity knob you can clearly see a world others don t see because frequency of occurrence is color coded Some oscilloscope vendors claim high waveform capture rates for short bursts of time but only the DPO7000 Series enabled by DPX technology can deliver these fast waveform capture rates on a sustained basis saving minutes hours or even days by quickly revealing the nature of faults so sophisticated trigger modes can be applied to isolate them File Edit Vertical HoriziAcq Trig Display Cursor Measure Mask Math MyScope Analyze Utilities Help B T T T U T T T T j T T T I U T WA AI U T U T U T FA DA N r ci Glitch 529mv 2 5ns 40 0GS s 25 0ps pt Sample 448 acqs September 09 2005 Isolate glitches down to 200 ps wide The Ability to Trigger an Oscilloscope on Events of Interest is Paramount in Complex Signal Debug and Validation Whether you re trying to find a system error or need to isolate a section of a co
20. below 60 C noncondensing Upper limit derated to 45 RH above 30 C up to 50 C Altitude Operating 10 000 ft 3 048 m Nonoperating 40 000 ft 12 190 m Random Vibration Operating 0 000125 G2 Hz from 5 to 350 Hz 3 dB octave from 350 to 500 Hz 0 0000876 G2 Hz at 500 Hz Overall level of 0 27 Grws Nonoperating 0 0175 G2 Hz from 5 to 100 Hz 3 dB octave from 100 to 200 Hz 0 00875 G2 Hz from 200 to 350 Hz 3 dB octave from 350 to 500 Hz 0 006132 G2 Hz at 500 Hz Overall level of 2 28 Grws Regulatory Electromagnetic 93 68 EEC EN61326 1997 A1 1998 A2 2000 Compatibility Certifications UL 3111 1 CSA1010 1 15011469 EN61010 1 IEC 61010 1 Ordering Information DPO7000 Series Product Description DPO7054 500 MHz Digital Phosphor Oscilloscope DPO7104 1 GHz Digital Phosphor Oscilloscope DPO7254 2 5 GHz Digital Phosphor Oscilloscope DPO7354 3 9 GHz Digital Phosphor Oscilloscope for Serial and Digital applications All Models Include Accessory pouch front cover mouse quick start user manual 071 173x xx DPO7000 Series product software media DPO7000 Series operating system restoration media Optional applications software media performance verification procedure PDF file GPIB programmer s reference on product software media calibration certificate documenting NIST traceability Z 540 1 compliance and ISO9001 power cord one year warranty Note User to specify quick start user manual language
21. e resolution The last mode is called the Manual mode because it ensures direct and independent control of the sample rate and record length With the MyScope Feature Create Your Own Control Windows With Only the Controls Features and Capabilities that You Care About Easily create your own personalized toolbox of oscilloscope features in a matter of minutes using a simple visual drag and drop process Once created these custom control windows are easily accessed through a dedicated MyScope button and menu selection on the oscilloscope button menu bar just like any other control window You can make an Digital Phosphor Oscilloscopes DPO7000 Series Horizontal 10GS s 100ps Click and Drag Controls onto the Tab below Glitch _ Width _ Timeout P n tom A TriggerType Setup Hold Edge Runt Transition _ Comm SetupHold Serial v Serial Video Window CAN Bus SPI I2C RS232 Drag and drop menu items of interest to create the MyScope control window unlimited number of custom control windows enabling each person who uses the oscilloscope in a shared environment to have their own unique control window MyScope control windows will benefit all oscilloscope users eliminating the ramp up time that many face when returning to the lab after not using an oscilloscope for a while and enables the power user to be far more efficient Everything you need is found in o
22. ement and Analysis Optional Power Measurement and Analysis Opt PWR Analyze power dissipation in power supply switching devices and magnetic components and generate detailed reports in customizable formats The Hi Res acquisition mode delivers greater than 8 bits of vertical resolution on single shot or repetitive signals at bandwidth up to 125 MHz The powerful and flexible measurements math and math on math capabilities make it an ideal solution for performing power measurements such as voltage current instantaneous power and energy for power device designers The new TekVPI interface provides smart communication between the oscilloscope and the probe TekVPI probe interface also provides more power to the probe interface allowing customers to directly connect current probes to the front of the oscilloscope Digital Phosphor Oscilloscopes DPO7000 Series TB 200mV 4 0ns Ci WAC 4 0ns 25 0GS s IT 8 0ps pt ma Horz Diy 10 4ns foa RL 5 0k March 12 2001 File Tests Results Utilities Help TDSET3 Select Result Summary 1000BASE T i RZ Template Test Point A Report Configuration Device Details URIS Configure So ii Hi Connect Report File rtGeneratoriLayouts 1000T rp p Clear Results Result Details Manual Fit Advance Enable Preview View Wim 1000 T gt Template gt 4 Data gt Ch1 Avg gt 64 Disturber gt No Ethernet compliance testing File Edit Vertical Horiz Acq Tr
23. ence Standard 10 million data points per channel on the DPO7000 Series Optional up to 400 million total data points on 2 5 GHz and 3 5 GHz models Optional up to 200 million total data points on the 500 MHz and 1 GHz models Easily manage this deep record length provide detailed comparison and analysis of multiple waveform segments with the MultiView Zoom feature Automatically scroll through deep records visually or create a math expression to instantly highlight differences Highest performance probing solutions for differential and single ended voltage signals as well as current measurement because accurate design verification depends on high bandwidth access to critical signals and high fidelity signal capture Tektronix Active probes achieve high speed signal acquisition and measurement fidelity Unmatched Versatility Get the Most of Your Oscilloscope by Fully Controlling its Waveform Acquisition and Display Parameters You have the choice of three horizontal time base modes of operations If you are simply doing signal exploration and want to interact with a lively signal you will use the Automatic or interactive default mode that provides you with the liveliest display update rate If you want a precise measurement and the highest real time sample rate that will give you the most measurement accuracy then the Constant Sample Rate mode is for you It will maintain the highest sample rate and provide the best real tim
24. ig Display Cursor Measure Mask Math MyScope Analyze Utilities Help 9 I I I I T j j j j GIP 100mV div ns 40 0GS s 25 0ps pt Single Seq 1 acqs RL 80 0k 21 juli 2006 Results Summary Signal Quality Check Eye Diagram Test Rise Time Pass CES Press the Result Status Plot Buttons for details of that test Monotonic Property Additional information Eye Diagram Signal Rate Fall Time EOP Width Overall Result Pass EOP Width Bits USB compliance testing Optional Ethernet Compliance Testing Opt ET3 Provides compliance testing for 10 100 1000Base T signals Optional USB Compliance Testing Opt USB Provides compliance testing for USB 2 0 signals Optional DDR Memory System Analysis Opt DDRA Accelerate the validation of a memory system based on DDR1 LP DDR1 DDR2 DDR3 or DDR variants technology like GDDR3 This new DDR search algorithm automatically detects the rates and the voltage levels of the data and strobe signals and marks every occurrence of read or write bursts You can then generate an eye diagram of the data or perform JEDEC standard measurements qualified on read or write bursts with DPOJET www tektronix com 9 Data Sheet pont a Optional Ultra Wideband Spectral Analysis and Ultra Wideband Spectral permane me peers ae Analysis Essentials UWBE Ultra Wideband microwave optical and electrical signals require more re
25. ion Opt C3 Calibration Service 3 Years Opt C5 Calibration Service 5 Years Opt D1 Calibration Data Report Opt D3 Calibration Data Report 3 Years with Opt C3 Opt D5 Calibration Data Report 5 Years with Opt C5 Opt R3 Repair Service 3 Years Opt R5 Repair Service 5 Years Recommended Accessories Probes Probe TCP0150 TCP202 6 TDP0500 TDP1000 TDP1500 TDP3500 TAP3500 TAP2500 TAP1500 TCP0030 TPA BNC P6139A P6158 P6247 6 P6243 6 P6245 6 P6248 6 P6250 8 P6251 8 P6330 6 P6246 6 P6101B TCPA300 TCPA400 6 P5200 P5205 P5210 6 P5100 P6015A Description 20 MHz TekVPI AC DC 150 A current probe DC coupled current probe 500 MHz TekVPI high voltage differential probe 1 GHz TekVPI high voltage differential probe 1 5 GHz TekVPI high voltage differential probe 3 5 GHz TekVPI high voltage differential probe 3 9 GHz TekVPI active single ended probe 2 5 GHz TekVPI active single ended probe 1 5 GHz TekVPI active single ended probe gt 120 MHz TekVPI AC DC 30 A current probe TekProbe BNC Level 2 to TekVPI adapter 500 MHz passive probe 3 GHz 20x low C probe 1 GHz differential probe 1 GHz active probe 1 5 GHz active probe 1 5 GHz differential probe 500 MHz TekVPI high voltage differential probe 1 GHz TekVPI high voltage differential probe 3 GHz differential probe 400 MHz differential probe 1x passive probe 15 MHz Series current measurement systems High voltage differential probes High voltage probes
26. ion to take measurements on Amplitude High Low Maximum Minimum Peak to Peak Mean Cycle Mean RMS Cycle RMS Positive Overshoot Negative Overshoot Rise Time Fall Time Positive Width Negative Width Positive Duty Cycle Negative Duty Cycle Period Amplitude Related Time Related Frequency Delay Combination Histogram Related Area Cycle Area Phase Burst Width Waveform Count Hits in Box Peak Hits Median Maximum Minimum Peak to Peak Mean u Standard Deviation sigma p 1sigma u 2sigma u 3sigma Extinction Ratio absolute dB Eye Height Eye Width Eye Top Eye Base Crossing Jitter p p RMS 6sigma Noise p p RMS Signal Noise Ratio Cycle Distortion Q Factor Eye pattern Related Waveform Processing Math Characteristic Arithmetic Algebraic Expressions Description Add Subtract Multiply Divide Waveforms and Scalars Define extensive algebraic expressions including Waveforms Scalars User adjustable Variables and Results of Parametric Measurements e g Integral CH 1 Mean CH 1 x1 414xVAR1 Math Functions Average Invert Integrate Differentiate Square Root Exponential Logo Log e Abs Ceiling Floor Min Max Sin Cos Tan ASin ACos ATan Sinh Cosh Tanh Relational Boolean result of comparison gt lt gt lt Frequency Domain Spectral Magnitude and Phase Real and Imaginary Functions Spectra Vertical Units Magnitude Linear dB dBm Phase
27. ith Opt SRL 3 400 M 1 CH 200 M 2 CH 100 M 4 CH DPO7054 DPO7104 DPO7254 DPO7354 100 ps 10 GS s 50 ps 20 GS s 25 ps 40 GS s 50 ps 20 GS s 25 ps 40 GS s 7 4 ms 2 MS 1 ms Length and Sample Rate 2 Ms 1 ms 8 ms 4 ms 2 MS 4 ms 2 Ms z 20 ms 10 ms 5 ms 10 ms 5 ms E with Opt 2SR Max Duration with Opt 10RL Acquisition Modes FastAcq Acquisition Mode Maximum FastAcq Waveform Capture Rate Waveform Database Sample Peak Detect Averaging Envelope Hi Res FastFrame Acquisition Roll Mode 12 www tektronix com 10 ms DPO7054 DPO7104 DPO7254 DPO7354 FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events gt 250 000 wfms s on all 4 channels simultaneously Accumulate waveform database providing three dimensional array of amplitude time and counts Acquire sampled values Captures narrow glitches at all real time sampling rates 1 sample rate at lt 10 GS s From 2 to 10 000 waveforms included in average From 1 to 2x109 waveforms included in min max envelope Real time boxcar averaging reduces random noise and increases resolution Acquisition memory divided into segments maximum trigger rate gt 310 000 waveforms per second Time of arrival recorded with each event Frame finder tool helps to visually identify transients Up to 10 MS s with a maximum record length of 40 M Pinpoint Trigger System DPO7054 DPO7104 DPO7254 DPO7354 Sensitivity
28. l Horiz Acq rig di DPOJET Plots tts CESSI SS SS a aren ATI PR L Shi TEL Es Sasmne 297MHz 299MHz 301 MHz 303MHz 305MHz Description Mean StdDev Max Min pp Population Max cc Min cc TIE1 Math1 1 7230ps 6 2394ps 36 320ps 37 371ps 73 690ps 3295389 15 627ps 16 194ps TIE2 Math 1 7230ps 6 2394ps 36 320ps 37 371ps 73 690ps 3295389 15 627ps 16 194ps E Period1 Math1 1 3352ns 5 1212ps 1 3528ns 1 3202ns 32 685ps 1647673 24 042ps 22 904ps m RJ1 Math1 4 5448ps 128 63fs 4 7572ps 4 3311ps 426 05fs 22 0 0000s 0 0000s Current Acquisition 4 6602ps 4 6602ps 4 6602ps 0 00008 1 0 0000s 0 0000s gt FEES ES EE ST m Current TETTO 14 989ps 14 989ps 14 989ps 0 0000s 1 0 0000s 0 0000s TJ BERI Math1 78 660ps 1 6559ps 81 467ps 75 914ps 5 5536ps 22 0 0000s 0 0000s Current Acquisition 80 232ps 80 232ps 80 232ps_ 0 0000s 1 0 0000s 0 0000s Jitter Timing and Eye Diagram Analysis Jitter Timing and Eye Diagram Analysis Jitter Timing and Eye Diagram Analysis Opt DJA Tight timing margins associated with today s serial buses demand stable low jitter designs DPOJET extends the oscilloscope capability by making jitter timing and eye diagram measurements over contiguous clock and data cycles in a single shot real time acquisition With multiple measurements and a variety of analysis tools including spectral and trend plots DPOJET quickly shows system timing under variable conditions It al
29. mplex signal for further analysis like a DDR read or write burst Tektronix Pinpoint triggering provides the solution The Pinpoint trigger system uses Silicon Germanium SiGe technology to provide trigger sensitivity of up to the bandwidth of the instrument and allows selection of most trigger types on both A and B trigger circuits It can capture very narrow glitches with very little trigger jitter Other trigger systems offer multiple trigger types only on a single event A event with delayed trigger B event selection limited to edge type triggering and often do not provide a way to reset the trigger sequence if the B event doesn t occur But Pinpoint triggering provides a full suite of advance trigger types on both A and B triggers with Reset triggering to begin the trigger sequence again after a specified time state or transition so that even events in the most complex signals can be captured Other oscilloscopes typically offer less than 20 trigger combinations Pinpoint triggering offers over 1400 combinations all at full performance With Enhanced Triggering you can choose to compensate for the difference in time there is between the trigger path and the display path and eliminate virtually any trigger jitter at the trigger point In this mode the trigger point can be used as a measurement reference Trigger on the Most Relevant Bit Sequence of the Industry Standard Serial Bus I2C Inter Integrated Circuit triggering is a st
30. mpliance tests Opt PWR DPOPWR Power Measurement and Analysis Software Opt SVE SignalVu Essentials Vector Signal Analysis software Opt SVP 10 Advanced Signal Analysis including pulse measurements Requires option SVE Opt SVM 10 General purpose Modulation Analysis Requires option SVE DPO7254 DP07354 only Opt PTM 5 8b 10b protocol triggering and NRZ serial pattern triggering Includes hardware clock recovery up to 1 25 Gb s and pattern lock triggering Opt RTE 5 RT Eye Serial data compliance and analysis software DPO7354 only Opt DVI 8 Digital Visual Interface compliance test software Bundle Options Opt PS1 Power Bundle option includes TPA BNC adapter Probe Calibration and deskew fixture 067 1686 xx P5205 TCP0030 and Opt PWR 16 www tektronix com User Manual Options Option Description Opt LO English manual Opt L1 French manual Opt L3 German manual Opt L5 Japanese manual Opt L7 Simple Chinese manual Opt L8 Standard Chinese manual Opt L9 Korean manual Opt L10 Russian manual Power Plug Options Option Description Opt AQ North America Opt A1 Universal European Union Opt A2 UK Opt A3 Australia Opt A5 Switzerland Opt A6 Japan Opt A10 China Opt A11 India Opt A99 No power cord Service Options Probes and accessories are not included in the oscilloscope warranty Refer to the data sheet for each probe for its unique warranty and calibration terms Option Descript
31. ms for Telecom User selectable Bandwidth Limit Filters for Better Low frequency and Datacom Industry Standards Measurement Accuracy Low speed Serial Bus Design I2C SPI CAN LIN RS 232 MyScope Custom Windows and Right Mouse Click Menus for ut i W Investigation of Transient Phenomena Exceptional Efficiency Event Search and Mark to Facilitate the Comprehension of Event Power Measurements and Analysis Relationships Spectral Analysis Tektronix Data Sheet 500 MHz DSF 250 0 MHz HW 20 0 MHz HW User selectable bandwidth limiting choices 500mV 100ps 51 5ms 50 5ms 500mV 2 0ps 51 2ms 51 2ms CTT 250mV 2 0ps 51 2ms 51 2ms Zoom in on four areas of interest simultaneously to compare them Unmatched Performance for Greater Insight Into Your Design to Get Your Work Done Faster The DPO7000 Series are the new generation of real time digital phosphor oscilloscopes and are the industry s best solution to the challenging signal integrity issues faced by designers verifying characterizing debugging and testing sophisticated electronic designs The family features exceptional performance in signal acquisition and analysis operational simplicity and unmatched debugging tools to 2 www tektronix com accelerate your day to day tasks The largest screen in the industry and the intuitive user interface provide easy access to the maximum amount of information Unmatched Acquisition Performance Sig
32. nal Fidelity of Tektronix Oscilloscopes Ensures Confidence in Your Measurement Results High sample rate on all models on all channels to capture more signal details transients imperfections fast edges 40 GS s on one channel on the 2 5 GHz and 3 5 GHz models Option 2SR to double the maximum real time sample rate for the 500 MHz and 1 GHz models High bandwidth up to 3 5 GHz matched across 2 3 or 4 channels and enabled by Tektronix proprietary DSP enhancement The user selectable DSP filter on each channel provides magnitude and phase correction plus extension to 3 5 GHz for more accurate signal fidelity for complex measurements The DSP filter on each channel can also be switched off to take advantage of true 2 5 GHz analog bandwidth for applications needing the highest available raw data capture The DPO7000 Series oscilloscopes include as a standard feature a series of user selectable bandwidth limit filters These filters preserve the instrument s bandwidth roll off characteristics flatness and phase linearity within the new frequency range thereby reducing the effects of out of band noise on measurements Now designers can purchase one instrument for their highest bandwidth needs and easily optimize it to handle lower frequency measurements as well Very low jitter noise floor and vertical accuracy for very accurate measurements Longest acquisition of the industry to provide more resolution and longer time sequ
33. ne control window rather than having to constantly navigate through menu after menu to repeat similar tasks www tektronix com 3 Data Sheet File Edit Vertical Horiz Acq Trig Display Cursor Measure Mask Math MyScope Analyze pH4 Ft tt tt ttt File Edit View Insert Format Tools Table Window Help Arial myo Si BZU ey 00 89 DEHA SRAY Bs na a BO0E Normal 16pt Times NewRoman 16 B Z U B 228 _ eooower e x eoeo y y V fre sf ip aes 2 0 000 a i 0006 6 le 22 wae TekWrToolbar xx 0004988 16 AMA i AE N ve amp 2 Mfg 0004984 16 26 s z 000498 14 22 ILs gga 0 aN 7 8 0004976 12 26 i5 2 Q Q N he 0004972 12 28 ao O OD Si gt Cc Gc Batch 16 0004968 14 24 288383383838328 s ala 0004964 12 2B Unit 2 000496 12 28 60 0004956 08 28 0004952 12 28 40 0004948 08 28 0004944 04 30 Capture data into Microsoft Excel using the unique Excel toolbar and create custom reports using the Word toolbar With OpenChoice Software Customize Your Test and Measurement System with Familiar Analysis Tools The analysis and networking features of OpenChoice software add flexibility to Tektronix Windows XP oscilloscopes Using the fast embedded bus waveform data can be moved directly from acquisition to anal
34. nto a 50 Q load Software Switchable BNC Connector External Time Base Reference In Time Base Reference Out Aux Trigger Output GPIB Port BNC connector time base system can phase lock to external 10 MHz reference BNC connector provides TTL compatible output of internal 10 MHz reference oscillator BNC connector provides a TTL compatible polarity switchable pulse when the oscilloscope triggers IEEE 488 2 standard Physical Characteristics Benchtop Configuration Dimensions mm in Height 292 11 48 Width 451 17 75 Depth 265 10 44 Weight kg Ibs Net 15 32 Shipping 28 9 63 75 Rackmount Configuration Dimensions mm in Height 331 12 29 Width 479 18 85 Depth from rackmounting 231 75 9 12 ear to back of instrument Weight kg Ibs Net 17 4 37 5 Rackmount Kit 25 55 Mechanical Cooling Required Clearance mm in Top 0 0 Bottom 0 0 Left side 76 3 Right side 0 0 Front 0 0 Rear 0 0 Digital Phosphor Oscilloscopes DPO7000 Series Environmental Characteristic Description Temperature Operating 0 C to 50 C excluding CD R W drive 10 C to 45 C including CD R W drive Nonoperating 40 C to 71 C Humidity Operating 5 to 95 relative humidity RH with a maximum wet bulb temperature of 29 C at or below 50 C noncondensing Upper limit derated to 45 RH above 30 C up to 50 C Nonoperating 5 to 95 relative humidity RH with a maximum wet bulb temperature of 29 C at or
35. nvestigate phase relationships and Safe Operating Area violations Select from 53 automatic measurements using a graphical palette that logically organizes measurements into Amplitude Time inv ir SBT T se rem toa Combination Histogram and Communications categories Gather further Gp ices tau ope some uppers eu insight into your measurement results with statistical data such as mean min max standard deviation and population Define and apply math expressions to waveform data for on screen results in terms that you can use Access common waveform math functions with the touch of a button Or for advanced applications create algebraic expressions consisting of live waveforms reference waveforms math functions measurement values scalars and user adjustable variables with an easy to use calculator style editor ain 20 048 20 0dB Basic spectral UI control window FFT To analyze your signal in the spectral domain use the basic spectral Filtering Enhance your ability to isolate or remove some important provides you with the best parameter or use advanced spectral with the component of your signal noise or specific harmonics of the signal by manual time base horizontal mode to directly control the frequency span creating your own filters or using the filters provided as standard with the center frequency and resolution bandwidth instrument www tektronix com 7 Data Sheet File Edit Vertica
36. pheral Interface triggering is a standard feature and includes triggering on a data pattern within a user definable frame RS 232 triggering is a standard feature CAN Controller Area Network triggering is an optional feature Opt LSA and includes synchronization to the Start or End of a CAN frame on any CAN high or CAN low signal triggering on Type of Frame Data Remote Overload Identifier Data Missing Acknowledge and Bit Stuffing error Analog HDTV EDTV Triggering for emerging standards like 1080i 1080p 720p and 480p as well as standard video triggering on any line within a field all lines all fields odd or even fields for NTSC SECAM and PAL video signals In addition IRE and mV graticules can be selected for easier measurements and visual inspection This is a standard feature www tektronix com 5 Data Sheet ng UL ULI a MI T DA Triggering on an analog HDTV trilevel sync signal and examining horizontal blanking interval Serial Pattern Triggering To debug serial architectures use the serial pattern triggering option for NRZ serial data stream with built in clock recovery available on models DPO7254 and DPO7354 only The instrument can recover the clock signal identify the transitions and decode characters and other protocol data With the combination of the Serial Trigge
37. r and Protocol Decode software you can see the captured bit sequences decoded into their words for convenient analysis for 8b 10b and other encoded serial data streams or you can set the desired encoded words for the serial pattern trigger to capture This serial trigger option covers NRZ serial standards up to 1 25 Gb s Pattern Lock Triggering adds a new dimension to NRZ serial pattern triggering by enabling the oscilloscope to take synchronized acquisitions of a long serial test pattern with outstanding time base accuracy Pattern lock triggering can be used to remove random jitter from long serial data patterns Effects of specific bit transitions can be investigated and averaging can be used with mask testing This feature is included as part of Option PTM on the DPO7254 and 7354 models Large 12 1 XGA Display Screen The DPO7000 Series has the largest display in the industry with a 12 1 XGA touch screen that gives up to 15 more waveform display than other oscilloscope series in its class 10 vertical divisions give you 25 more vertical measurement resolution 6 www tektronix com How does 12 1 display compare to the display size of other oscilloscopes Unmatched Usability The TekVPI probe interface provides versatility and ease of use enabled by intelligent bidirectional oscilloscope to probe communication The DPO7000 Series are fast responding instruments and contain a comprehensive suite of features such
38. resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 01 Apr 2009 4MW 19046 13 Tektronix
39. so provides Rj Dj on signals without a repeating pattern and without requiring a fixed pattern or length You can get insight into the signal characteristics like SSC profile using the analysis features and perform pass fail testing using eye diagram masks and limit files for testing against statistical limits using the compliance features This tool is available for the DPO7000 Series as Opt DJA and Opt DJE Advanced Event Search and Mark Opt ASM Event Search and Mark will relieve the user from the tedious task of examining data by highlighting important events skipping the unimportant ones and enhancing the comprehension of event relationships You can navigate between the events of interest effortlessly A basic event edge only search and mark is provided as a standard feature and support for more advanced event types like transition setup and hold or logic pattern is provided with the ASM option 8 www tektronix com zIAC Trig Display Cursors Measure Mask Math MyScope Analyze ilities e GIP 300mV div 500 8y 8 0G F 600mV 4 0ns GTP 300mV div 500 By 8 0G CTT 100mV 4 0ns TTP 100mV div 500 By 8 0G CIT 300mV 2 0ns FIT 600mV 4 0ns 20 6ns 19 4ns fT 300mV 2 0ns Single Seq acqs RL 500k Cons June 05 2007 CTD StHid 2 0us 25 0GS s 40 0ps pt Results Mark Table _ Transition E Transition Transition 164 9ns 000 000 E 44 96ns 000 000 000 119 960 Transition time 5 4ns A 000 000 304 000 000
40. ts specified in binary high low don t care or hex format Trigger on NRZ encoded data up to 1 25 Gb s Video Type Trigger Triggers from negative sync composite video field 1 Formats and Field Rates or field 2 for interlaced systems any field specific line or any line for interlaced or noninterlaced systems Supported systems include NTSC PAL SECAM and HDTV 1080 24sF 1080p 25 1080i 50 10801 60 1080p 24 720p 60 480p 60 Low speed Serial Protocol Trigger Type A Event only Main Trigger Modes Enhanced Triggering Trigger Sequences Clock Recovery System On DPO7254 or DPO7354 only and requires Opt PTM or MTM Clock Recovery Phase Fixed at FBaud 500 Locked Loop Bandwidth Frequency Range 1 5 MBaud to 1 25 GBaud Clock Recovery Jitter 20 psrms 1 25 Unit Interval RMS for PRBS data RMS patterns 20 psrms 1 25 Unit Interval RMS for repeating 0011 data pattern Tracking Acquisition 5 of requested baud typical Range Minimum Signal 1 divp p up to 1 25 GBaud typical Amplitude needed for Clock Recovery Trigger Level Range 12 divisions from center of screen Internal AUX Trigger TekVPI interface 5 V 50 Q 150 V CAT derate at 20 dB decade to 9 Vans above 200 KHz 1 MQ Line Fixed at 0 V Trigger Coupling DC AC attenuates lt 60 Hz HF Rej attenuates gt 30 kHz LF Rej attenuates lt 80 kHz Noise Reject reduces sensitivity Trigger Holdoff Range 250 ns min to 12 s max Digital Phosphor
41. ysis applications on the Windows desktop at much faster speeds than conventional GPIB transfers Tektronix implementation of industry standard protocols such as TekVISA interface and ActiveX controls are included for using and enhancing Windows applications for data analysis and documentation IVI COM instrument drivers are included to enable easy communication with the oscilloscope using GPIB serial data and LAN connections from programs running on the instrument or an external PC Or use the Software Developer s Kit SDK to help create custom software to automate multistep processes in waveform collection and analysis with Visual BASIC C C MATLAB LabVIEW LabWindows CVI and other common Application Development Environments ADE Integration of the oscilloscope with external PCs and non Windows hosts is also supported by the DPO7000 Series software solutions In addition the OpenChoice architecture provides a comprehensive software infrastructure for faster more versatile operations Data transfer programs such as the Excel or Word toolbar are used to simplify analysis and documentation on the Windows desktop or on an external PC 4 www tektronix com File Edit Vertical Horiz amp cq Trig Display Cursor Measure Mask Math MyScope Analyze iliti ns 40 0GS s 25 0ps pt Sample 273 408 acqs September 09 2005 Maximize the probability of capturing elusive glitches and other infrequent events with F

Download Pdf Manuals

image

Related Search

Related Contents

Martin BOURDANOVE / Informations  Manual de Instruções Bimby ® Clássica (TM31)  LM-5000 Manual del usuario - Franklin Electronic Publishers, Inc.  les de l`appareil - Migros  Method and apparatus for synchronization of two computer systems  IKEA FUGA AA-122454-1 User's Manual  Relazione annuale di bilancio 2009  取扱説明書  