1. San Tube temp sensor W15 RTI SW water level 7 Main switch 2 ate W16 BK BK I 671819110 YLI BL WH BK RD Fan motor X 9 X5 Xi X8 XT FUSE1 50T 3 15A 250VAC FUSE2 50T 0 250VAC 12 X101 AC BN gr di L BL 1 N X10 x9 X104 AC N xe E V V CONP2 CPI YL GN V V X103 X102 B Capacitor Power 50Hz 220V lt lt BK RD RD 1 du HS Motor protector 5 1 4RD 5GN N AY 24 Indicatorlamp Indicator lam E 5 2 j or water level Q gt 1802 d Compressor Fig 1 8 Dehumidifier 1 5 2 Circuit diagram for CFO 5E CF0 8E This circuit diagrams are subject to change without notice Please refer to the ones stuck on the machines W13 ST OR Temp sensor Fan motor 2s ICE N g 3 8 8 W12 Wi N A RD BN BN X6 MH RD AP1 7 u H OR GN APC gt BK 1456 ON FUSELSOT 315A 250VAC BK FUSE2 50T 0 24 290VAC 18 X4 AV BN x5 BL
2. X5 X7 YL GN 2 Capacitor BK BK BK RD i Ss 0 19 Motor protector 5 9 lt 1 3GR 3 4RD 5GN Switch for Indicator lamp water level Compressor Fig 1 9 DEUM LA tb xw TE Power 50Hz 220V Dehumidifier 1 6 PCB function manual Control for M type A Main control function Dehumidify B Aim of the control 1 Fan motor include drying clothes dehumidifying and silence 2 Compressor 3 Full lamp 4 Power lamp C The input parameter of the PCB 1 Temperature of the environment T Ring Detect only before the starting of the compressor 2 Temperature of the tube of the Evaporator T Tube the same tube temperature sense as T Ring 3 Liquid switch S Liquid 4 Quick detect switch 5 Work mode of the main switch D Work voltage 220 230V Frequency 50Hz E Systematic diagram of the dehumidifying cycle evaporator condenser Humidity air gt Dry air COMPRESSOR gt Drainage tank F The way of the control in each mode This unit have only one Main Switch including OFF silence dehumidifying and drying clothes When the unit is connected with power the power lamp light 1 OFF turning the switch to OFF the unit will stop running 2 Silence compressor startup fan motor is running at low wind speed 3 Dehumidifying compressor startup fan motor is running at medium wind speed 4 Dryin
3. 26233432 26233432 26233432 26233432 Evaporator 26 R 01036501 01036501 01036503 01036503 5 EE 01136501 01136501 01136503 01136503 Fixing clamp 20196501 20196501 20190000 20190000 Cover of propeller housing 12104110 12104110 12104110 12104110 Positioning sticker E 10511133 10511133 10511133 10511133 Nut 70310133 70310133 70310133 70310133 Centrifugal fan 10356501 10356501 10356501 10356501 Grille 22416551 22416551 22416551 22416551 Motor L 15016501 15016501 15016501 15016501 Propeller housing Ft 12102010 12102010 12102010 12102010 PCB ERR 1701 30021002 30021002 PCB 18F1 30021001 30021001 Comp Capacitor Compressor afafafajajoafafjajafajaja zxfalalolalo min The data are subject to change without notice Dehumidifier 1 5 Circuit diagram 1 5 1 Circuit diagram for CF0 5M CF0 8M This circuit diagrams are subject to change without notice Please refer to the ones stuck on the machines Indoor temp sensor 5 Switch for
4. 0 58 Evaporator Aluminum fin copper tube Row fin distance mm 8 1 8 Working area m 0 053 Condenser uminum fin copper tube Row fin distance mm 8 1 8 Working area m 0 053 Compressor model Reciprocating Compressor Power W AE1340YZ AE1360YZ 297 AE1370YZ Protect equipment 4TM232PFB 4TM424PFB 4TM435PFB Starting method Working current A PTC 1 9 Working temp Exhaust temperature lt 115 C Throttling method Capillary Fuse A 3 15 Noise dB A Width mm 47 dimension Height mm Depth mm Net weight kg Refrigerant Refrigerant charge g The technical data are subject to change without notice Please refer to the nameplate of the unit Dehumidifier 2 3 Outlines and dimensions Fig 2 2 Fig 2 3 302mm Fig 2 4 Fig 2 5 18 Dehumidifier Blank 19 Dehumidifier 2 4 Explosive view and spare parts list 16 LV i Y Fig 2 6 90 Dehumidifier Table 2 2 z o Description Part No 5 CF0 7M A lt 22206512 22206512 22206512 10516508 10516508 10516508 Board for i
5. 6502 Isolation sheet 01236501 01236501 01236501 Compressor and fittings AE1340YZ 00100153 AE1360YZ 00100154 AE1370YZ The data are subject to change without notice ELE 00100152 afaj ofafjafa pljafjajajafa afafajafa aa fa fa far far far far far sr Dehumidifier 2 5 Circuit diagram This circuit diagrams are subject to change without notice Please refer to the ones stuck on the machines WATER SWITCH TUBE TEM SENSOR loo cou Nan XT2 e MAIN SWITCH 4BN gp FAN MOTOR SBK 9RD A X105 X8 IN BN X101 BL LN B BL E X102 X104 pe V Y POWER 220 230V 50Hz LED 1772 M O TYE GN E E COMPRESSOR Fig 2 7 2592 Dehumidifier 2 6 PCB function mannul A Main control function Dehumidify B Aim of the control 1 Fan motor include low speed and high speed 2 Compressor 3 Full lamp 4 Power lamp C The input parameter of the PCB 1 Temperature of the environment T Ring Detect only before the starting of the compressor 2 Temperature of the tube of the Evaporator T Tube the same tube temperature sense as Ring 3 Liquid switch S Liquid 4 Quick detect sw
6. Dehumidifier 1 CFO 5E CF0 5M CFO 8E CFO 8M type 1 1 Summary CF0 5M CFOSE CF0 8M Fig 1 1 Fig 1 2 Dehumidifier 1 2 Technical specifications Table 1 1 Model CFO0 5E CF0 8M Power supply 1Ph 220 230V 50Hz Dehumidifying Capacity L day Rated input W Rated current A 0 9 1 8 Air flow 120 150 Fan speed rpm Motor Output power W 520 450 400 570 510 450 Working capacitor uF Fan type piece Axial fan 1 Diameter length 234 46 Evaporator Aluminum fin copper tube Row fin distance mm 10 1 8 12 1 6 Working area m 0 047 0 056 Condenser Aluminum fin copper tube Row fin distance mm 10 1 3 12 1 3 Working area m 0 047 0 056 Compressor model Rotary Compressor Power W XB357VMCC 170 YB645VMCC 295 Protect equipment LYDN 96X LYGN 78X Starting method Working current A capacitor 0 8 1 4 Working temp Exhaust temperature lt 115 C Compressor capacitor uF 4 8 6 5 Throttling method Capillary Fuse A Noise dB A Width mm dimension Height mm Depth mm Net weight kg Refrigerant Refrigerant charge g The technical data are subject to change without notice Please refer to the nameplate of the unit Dehumidifier 1 3 O
7. Jiesheng Sheng Zhiguo CONTENT 1 CF0 5E CF0 5M CFEO BM type 1 me 1 1 2 Technical Soo a 3 1 3 Q tlines and CIMTGTISIOING PENNE UU TS 4 1 4 Explosive view and spare parts list nun ne ia 6 USIA AU E PAP EET 8 LO PCB MCR I ee DUN 10 2 CF0 5M A CFO 7M A type zu untere 15 2 Me MIMI MN 15 2 2 Technical specifications nee 17 2 9 Outlines and dimensions sii ee 18 2 4 Explosive view and spare parts 20 25 Circuit diagram ee 22 26 PGB UNION 23
8. compressor start for 10 minutes if detect T Tube lt 5 C for continuous 3 minutes compressor will stop and Fan motor maintain running state when T Tube 4 C or the time of the defrosting reach 20 minutes compressor will reset and fan motor maintain running state 5 High temperature mode when T Ring gt 35 the high temperature mode startup Fan motor only can ran at high speed and mode key is inactive F Quick check function When S quick detector is in short circuit running one second will consider as one minute This function only use for test in usual time S quick detector should break 43 Dehumidifier 44 Dehumidifier 2 CF0 5M A CFO 7M A CFO 8M A type 2 1 Summary Wa M mm D LS a a P HO 9 3 ma 7 r iii nonss e a _ AA Fig 2 1 15 Dehumidifier 2 2 Technical specifications Table 2 1 Model CF0 5WA CFO 7M A CF0 8M A Power supply 1Ph 230V 50Hz Dehumidifying Capacity L day 12 16 20 Rated input W Rated current A 250 420 1 9 Air flow M9 h 150 Fan speed rpm Motor Output power W 900 740 Working capacitor uF Fan type piece Axial fan 1 Diameter length 16
9. g clothes compressor startup fan motor is running at high wind speed 10 Dehumidifier G Protect function 1 Work range set T1 4 C T2235 C when T Ring lt T1 1 C or T Ring gt T2 1 C compressor doesn t start in order to protect the units from working in bad environment and fan motor maintain running state 2 3 minutes protect After you stop running put through power supply to renew start fan motor startup compressor automatically delay 3 minutes to startup 3 Water full protection when water is full in water tank Full Lamp will light compressor will stop and fan motor maintain running state 4 Anti freezing function After the compressor start for 10 minutes if detect T Tube lt 5 C for continuous 3 minutes compressor will stop and Fan motor maintain running state when T Tube 4 C or the time of the defrosting reach 20 minutes compressor will reset and fan motor maintain running state 5 Tube Temperature Sensor Protect When detect T Tube lt 30 C T Tube gt 80 C system run into OFF mode only the power lamp light H Quick detect function When S quick detector is in short circuit running one second will consider as one minute This function only use for test in usual time S quick detector should break Control for E type A Main control function Dehumidify B Aim of the control 1 Fan motor include drying clothes dehumidifying and silence 2 Compressor 3 Mode lamp drying clot
10. hes dehumidifying and silence 4 humidity lamp continuous dehumidify 50 60 70 5 Full lamp C The input parameter of the PCB 1 Temperature of the indoor environment T Ring Detect only before the starting of the compressor 2 Temperature of the tube of the Evaporator T Tube the same tube temperature sense as T Ring Humidity of the indoor environment H Ring Power switch S switch Mode switch S mode Humidity select S humidity Liquid switch S Liquid Quick detect switch S quick detector CON DOO FW Dehumidifier D Systematic diagram of the dehumidifying cycle evaporator condenser Humidity air Dry air COMPRESSOR gt O Drainage tank E Main control function 1 Control key 1 S switch Control On and Off When adding electricity power lamp light press switch key to start running with default mode press switch key again to stop running 2 S mode Press this key you can control system s 4 mode corresponding mode indicator light will bright silence low wind speed dehumidify medium wind speed drying clothes high wind speed Starting default mode is dehumidify mode 3 S humidity Set dehumidify of room 4 kinds continuous dehumidify 50 60 70 corresponding mode indicator light will bright Starting default mode is con tinuum mode 2 Humidity control Press the humidity select key the unit will run continuously without the humidit
11. itch 5 Work mode of the main switch D Work voltage 230V Frequency 50Hz E Systematic diagram of the dehumidifying cycle evaporator condenser Humidity air Dry air COMPRESSOR gt O Drainage tank F The way of the control in each mode This unit have only one Main Switch including OFF LOW and HIGH three sites When the unit is connected with power the power lamp light 1 OFF turning the control switch to OFF the unit will stop running 2 Low Turn the control switch to Low compressor will start if only the condition permits and the fan motor will run at low speed 3 High Turn the control switch to High compressor will start if only the condition permits and the fan motor will run at high speed G Protect function 1 Work range set T1 4 C T2235 C when T Ring lt T1 1 C or T Ring gt T2 1 C compressor don t start in order to protect the units from working in bad environment and fan motor maintain running state 93 gt Dehumidifier 2 3 minutes protect After you stop running put through power supply to renew start fan motor startup compressor automatically delay 3 minutes to startup 3 Water full protection when water is full in water tank Full Lamp light compressor will stop and fan motor maintain running state 4 Anti freezing function If the compressor has run for 10 minutes and detect T Tube lt 5 C for continuous 3 minutes compressor will stop and Fan
12. motor maintain running state 5 Tube Temperature Sensor Protect When detect T Tube lt 20 C or T Tube gt 80 C system run into OFF mode only the power lamp light H Quick detect function When S quick detector is in short circuit running one second will consider as one minute But in anti freezing mode the quick detector will work in this way after compressor s starting for 20 seconds if checked tube temperature 5 C anti freezing starts work compressor stop and fan motor maintain running state The compressor will not start until detected tube temperature 4 C This function only use for test in usual time S quick detector should break 24 TECHNICAL SERVICE MANUAL Dehumidifier Series GREE ELECTRIC APPLIANCES INC OF ZHUHAI Jinji West Rd Qianshan Zhuhai Guangdong China Introduction In this technical service manual you will find rich references to Dehumidifier Series products including photos technical specifications explosive views spare parts lists and circuit diagrams Service people and engineers of Gree s customers and distributors would find it a very handysource of technical information of our products Technical Support Department GREE ELECTRIC APPLIANCES INC OF ZHUHAI Nov 2002 Editor In Chief Chen Jianmin Compiler Chen Zhian Ouyang Jun Tian Guoku Yang Rong Jia Tianwei Cao Xuan Wang Min Proofreader Zhang Yuanzhong He Jiefeng Jin Gang Li Gangxiang Designer of Cover Li
13. nstalling motor LRI 01336503 01336503 01336503 Fan motor iL 15016502 15016502 15016502 Pipeline ER RR 06106503 06106502 06106501 Board for installing controller Ll RA 01336502 01336502 01336502 PCB1901 imas 1901 30021009 30021009 30021009 o Top cover Knob ll 22246506 45036502 22246506 45036502 22246506 45036502 main switch 45016505 45016505 45016505 Condenser assy Evaporator assy EZ HH Re aad 01106507 01006507 01106506 01006506 01106506 01006506 Capacitor CBB61 2uF 450VAC H7 CBB61 2uF 450VAC 33010025 33010025 33010025 Terminal board 2 8 FRE 2 8 42011103 42011103 42011103 Water tray fe 7K E 20186506 20186506 20186506 Switch for water level WMT 45016506 45016506 45016506 Front plate Hif 20006506 20006506 20006506 Filter 11126506 11126506 11126506 Buoy 26116510 26116510 26116510 Water box Handle 20186509 26236501 20186509 26236501 20186509 26236501 Truckle 24236553 24236553 24236553 Strip for fixing power cord Meter base 01726505 01216502 01726505 01216502 01726505 0121
14. utlines and dimensions Fig 1 3 Fig 1 4 Fig 1 5 Fig 1 6 Dehumidifier Blank Dehumidifier 1 4 Explosive view and spare parts list Dehumidifier Table 1 2 Part No Description lt CF0 5M CFO 5E CF0 8M CF0 8E Air guider F 10512384 10512384 10512384 10512384 Front case f 01513420 01513420 01513420 01513420 Main switch SFG 45010301 45010301 Lo volt PCB Siagi LAR 18 1 30021001 30021001 Knob supporting plate 70411204 70411204 Button supporting plate 45037004 45037004 Knob 20106010 20106010 Protecting plate 01491531 01491531 01491531 01491531 Buoy supporter e bn 12497002 12497002 12497002 12497002 Buoy E 12497001 12497001 12497001 12497001 Water tank 20186505 20186505 20186505 20186505 Z 4 8UF 450VAC 33000028 33000028 Z 6 5UF 450VAC 33010032 33010032 Water tray E 12412050 12412050 12412050 12412050 Base assy IH 22226504 22226504 22226504 22226504 Castor 24236551 24236551 24236551 24236551 Crank LE 10546521 10546521 10546521 10546521 00100040 00100040 00100041 00100041 Gasket 3 70411201 70411201 70411201 70411201 LS mE 06106421 06106421 06102422 06102422 FE HR 70140555 70140555 70140555 70140555 WE A 11126503 11126503 11126503 11126503 Rear case 01513413 01513413 01513413 01513413 Handle F
15. y compare in 10 seconds 50 when detect H Ring lt 45 stop the unit H Ring gt 55 run the unit 60 when detect H Ring lt 55 stop the unit H Ring gt 65 run the unit 7096 when detect Ring lt 65 stop the unit H Ring gt 75 run the unit continuous dehumidify the unit runs continuously 3 Mode The system have 4modes Off Dehumidify Drying clothes and Silence OFF compressor and fan motor stop mode lamp and humidity lamp extinguish power lamp light Dehumidifying humidity lamp light others extinguish fan motor is running at medium wind speed compressor startup Drying clothes Drying clothes lamp light others extinguish fan motor is running at high wind speed compressor startup Silence Silence lamp light others extinguish fan motor is running at low wind speed com pressor startup 12 Dehumidifier 4 Protect function 1 Work range set T1 2 C T2238 C when T Ring lt T1 1 C or T Ring gt T2 1 C compres sor don t start in order to protect the units from working in bad environment and humidify lamp light humidify and switch key is active mode key is inactive 2 3 minutes protect After you stop running put through power supply to renew start fan motor startup compressor automatically delay 3 minutes to startup 3 Water full protection when water is full in water tank Full Lamp will light compressor and fan motor will stop 4 Anti freezing functior After the