Home

Data Sheet 85006-0067 -- FireWorks Specifications & Ordering

image

Contents

1. EST Life Safety amp Communications FireWorks Graphical Command Interface Hardware and Ordering Information For detailed application and operation information please see Data Sheet 85006 0049 Overview FireWorks is a family of software and hardware options that work in concert with Edwards Emergency Communication System Mass Notification System Life Safety System ECS MNS LSS FireWorks provides an intuitive user interface taking what could be an overwhelmingly large amount of information and presenting it in an easy to understand format FireWorks does this by dividing major system functions into easy to manage viewports These viewports make the system intuitive to use because information is presented logically FireWorks is event driven This greatly increases the user s ability to deal with system events by eliminating the confusion some times experienced when systems present all information at once FireWorks automatically prioritizes the events for the user in an Event Viewport Here the highest priority event is displayed first and the lowest priority event is displayed last This allows the user to quickly determine which events warrant the most immediate attention Each of the other supporting viewports provides specific informa tion and or control options that relate to the event highlighted in the Event Viewport Related information may include event action information specific tasks the user may need
2. of 4 Screen Resolution Speakers Mounting Environment Touch Screen Brightness Approvals 1440 x 900 VGA Two built in speakers in display head Use FW 19LCDWRACK rack mount kit O to 49 C 32 to 120 F 5 to 93 RH noncondensing Capacitive w USB Controller 230 cd m typical UL ULC see Note 1 Monitors 22 black Liquid Crystal Display FW 22LCDWTS Dimensions W x H x D 20 2 x 15 9 x 8 7 in 513 08 x 403 86 x 221 8 mm Diagonal Viewing area Weight Power Screen Resolution Speakers Mounting Environment Touch Screen Brightness Approvals 16 5 Ibs 7 48 kg with touch screen and base 120 VAC 1 5 A 60 Hz 180 W max 1680 x 1050 WSXGA Two built in Speakers Desk mount O to 49 C 82 to 120 F 5 to 938 RH noncondensing Capacitive w USB Controller 300 cd m typical depending on panel spec UL ULC see Note 1 Monitors 42 black Liquid Crystal Display FW 42LCDWTS Dimensions Ala x252 5 0 In W x H x D 1049 x 640 x 127 mm Diagonal Viewing area Weight 70 lbs 32 kg Power 120 VAC 1 97 A 60 Hz 236 W max Screen Resolution 1920 x 1080 Speakers N A Mounting Wall mount Order kits separately 0 to 49 C 32 to 120 F Environment Touch Screen Brightness Approvals Cables 5 to 938 RH noncondensing Capacitive touch screen 500 cd m typical UL ULC see Note 1 Comes with standard VGA power and USB cable Software Options FW CGSUL FW CG
3. S SV SV FW 1S FW 4S FW 10S FW DARCOM FW IPMON1000 Color Graphics Software supports Text Annunciation Graphics and Reports Must be run on UL listed PC Provides a full featured Event driven six viewport graphic display Supports IRC 3 EST2 FCC and ESTS systems Allows Text annunciation with graphics Provides event driven six viewport graphic display No common control Use with IRC 3 EST2 FCC and EST3 systems SiteVision Allows use of existing CCTV monitors with control of CCTV system No on screen control provided at FireWorks PC Operates with FW CGS UL series software Supported CCTV systems See Note 2 SiteVision Provides on Screen annunciation of CCTV at FireWorks PC Allows control of cameras through CCTV matrix or multiplexer Operates with FW CGS UL series software Supported CCTV Systems See Note 2 FW VIDTVC required order separately One seat Web client Used in conjuction with FW 1S provide 4 additional concurent remote client seats for a total of 5 concurrent seats supported Used in conjunction with FW 1S and FW 4S to provide a total of 15 concurrent remote client seats Provides connectivity for 1 to 8 Digital Alarm Receivers IP Monitoring for 1000 connections to iO series panels Requires companion software option FW DARCOM 85006 0067 Issue 3 EDWARDS Contact us Email edwards fire fs utc com Web wwwest fire com EST is an EDWARDS brand 1016 Corporate Park Drive M
4. ebane NC 27302 In Canada contact Chubb Edwards Email inquiries chubbedwards com Web www chubbedwards com 2013 UTC Fire amp Security Americas Corporation Inc All rights reserved Specifications subject to change without notice Edwards is part of UTC Climate Controls amp Security a unit of United Technologies Corporation Notes Ordering Information Standalone Workstations FWULSW7 FWULSRAIDW7 Workstation see notes Dual Core 3 0 GHz processor comes with Windows 7 Ultimate 64 bit DVR RW 4 Gig RAM memory 500 Gig Hard drive on board sound card on board video 8 USB ports auto ranging 120 220Vac 50 60 Hz power supply Order serial interface card or network interface card monitor mounting hardware Fireworks Application software and other optional cards separately Same as FWULSW 7 but with a 500 Gig RAID Hard drive array configured as RAID 1 for redundant drive mirroring Optional Components FW SP4I FW NIC FW MOD FW HDSW7 FW HDSRAIDW7 FW NCCAS Monitors FW 19LCDWTS FW 22LCDWTS FW 42LCDWTS Serial Port for UL ULC listed FWL5W7 or FWULSRAIDW7 workstations Provides four serial ports Occupies one PCI slot Maximum two FW SP4I cards per workstation UL ULC Listed Ethernet 100Base TX Network Interface Card Modem for UL ULC listed systems 56K baud V 90 Replacement hard drive for FW UL57 computer Replacement hard drive for FWULSRAIDW7 computer Network conduit adapter Provide
5. eceiver Connectivity Provides the ability to monitor and display events from fire and security panels of different manufactures at a common location 85006 0067 Issue 3 Typical Direct Connections Compatible Compatible Optional Edwards Edwards Panel Network Edwards Redundant Data Connections Fire Panel Fire Panel Fire TTT OULU COLE Panel Compatible oo Edwards dial Digital Fire Panel Alarm Receiver CTL eC Notes Security RS 232 lines are supervised and power limited Maximum length 50ft 15 24 m Panel each FireWorks meets UL864 category UJOZ when UPS backed up and rack mounted or when used with PCCA5 Contact your AHJ for other application configurations Typical Network Deployment Dedicated Ethernet Network MN FVPN wy MN NETRLY4 Non Dedicated Network ESIK Control Panel 7 Note FireWorks meets UL864 category UJOZ when UPS backed up and rack mounted or when used with PCCA S When using Ethernet an FW NIC and FW NCCAS are required Contact your AHJ for other application configurations Installation and Mounting FireWorks meets UL requirements when desk floor or rack mounted For floor and desk mounting a PCCA 5 ordered sepa rately must be used for conduit connection of PC to junction box The FireWorks workstation must be UPS backed Uninterruptible Power supplies UPS meeting UL1481 Power Supplies for Fire Pr
6. l mount bracket kit single display vertical 42 wall mount bracket kit dual display vertical Computer rack mount kit 4 EIA panel spaces required C W slides amp handles Keyboard Rack mount kit Black 2 EIA panel spaces required Rack mount slides for use with FW RACK PC Blank plate One EIA panel Space 1 75 x 19 See Note 3 Blank plate Two EIA panel Spaces 3 5 x 19 See Note 3 Blank plate Three EIA panel Spaces 5 25 x 19 See Note 3 Accessory Enclosure for mounting Mini Mux at FireWorks workstation UL 864 FireWorks Communications Ethernet Port Command amp Control Unmanaged Layer 2 Ethernet Switch 6 5 Amp Auxiliary Power Supply 10 Amp Auxiliary Power Supply Ethernet controllable multi I O module 4 unsupervised inputs amp 4 unsupervised outputs Comes with one MN NRKB1 Voice Over Internet Protocol VoIP encoder decoder includes power and audio cable 10 Position 4 pole terminal kit for use with MN NETRLY4 or MN FVPN MN COM1S or MN NETSW1 mounting bracket for MFC A enclosures or on 3 CHAS7 85006 0067 Issue 3 EL 72 90
7. otective Signaling Systems and UL 864 category UTRZ required Page 2 of 4 85006 0067 Issue 3 Specifications FireWorks CPU FWUL5W7 and FWUL5SRAIDW7 Computer Type Harddrive Dimensions Weight Keyboard and mouse Power Supply RAM Operating System Fire Systems Monitored Controlled Communication format Log text Graphic Zoom fields History archive Operator Log On Log Off Operating Temperature Relative Humidity Optical Drive Mounting Approvals USB Ports PCI Expansion Slots Serial Ports Network Interface RAID 1 hard drive array Industrial Grade Dual Core 3 0 GHz Intel processor 800MHz front side bus 500 GB 17 wx 22 5 dx7 h 432 mm x 572 mm x 177 mm 44 lbs 20 0 kg Actual Weight depends on the installed options Standard 101 key black Black two button PS2 mouse 350 Watts voltage range selected automatically Acceptable inputs are 100 127 nominal Vac 50 60 Hz 6 Amps max 200 240 nominal Vac 50 60 Hz 3 Amps max PC comes with conduit adapter for AC connection when desk or Tower mounting 4 GB standard Windows 7 Ultimate 64 Bit ESTS or EST2 non networked iO Series IRC 3 FCC EST8X can be connected only through an EST3 panel network RS 232 and or TCP IP connections to systems via optional cards 65000 characters per event Max Unlimited 82 max recommended Subject to hard drive space budget 2 meg per 10 000 events Three security control acces
8. s connection to FW NIC for Ethernet conduit Rack mount UL ULC 19 LCD 1440 x 900 capacitive TS order FW 19LCDWRACK Rack mount kit separately UL ULC Listed 22 16 9 LCD 115 Vac 1680 X 1050 resolution capacitive touchscreen with integral soeakers C W desk stand cable set driver disk UL ULC Listed 42 16 9 LCD 115 Vac 1920x1080 resolution surface acoustic wave SAW touchscreen with integral soeakers Comes cable set and driver disk Requires wall mounting bracket kit ordered separately Enclosures and Mounting Accessories RKU 61 24B FW 19LCDWRACK FW 42LCDHMkK1 FW 42LCDVMkK1 FW 42LCDVMkK2 FW RACKPCULS 1 All FireWorks workstations come standard with mouse control 2 FireWorks meets UL864 category UJOZ when rack mounted or when used with PCCA The system must be UPS backed up Approval by AHJ may be required for other applications 3 One EIA panel space is 1 75 in height While every effort is taken to ensure that specifica tions accurately represent FireWorks workstations Edwards reserves the right to change FireWorks computer hardware and or software specification without notice Page 4 of 4 FW RACKKB FW RACKSD BP1 BP2 BPS MFC A Accessories MN COM1S MN NETSW1 APS6A APS10A MN NETRLY4 MN FVPN MN TK10 MN BRKT2 19 Rack mount enclosure black color 35 EIA panel spaces available Rack mount kit for model FW 19LCDWTS monitor 42 wall mount bracket kit single display horizontal 42 wal
9. s levels Complete customization of user access attributes by password 0 to 49 C 32 to 120 F 5 to 95 non condensing DVD RW Desktop or floor mounting or Rack Panel mount in 19 RKU series Use RKU 61 24 when rack mounting UL ULC see Note 1 Eight USB ports two on front six on rear Four PCI slots one PCI express slot Order FW SP4i separately to obtain four serial ports occupies one PCI slot Order FW NIC and FW NCCAS for Ethernet 100Base TX connections occupies one PCI slot Specify FWULSRAIDW7 computer for standard features plus RAID 1 mirrored hard drive array Rack Mount LCD Monitors 19 black FW 19LCDWTS Dimensions W x H x D Diagonal Viewing area Weight Power Note 1 174x156 x 8 0in 441 96 x 396 24 x 203 2 mm 19 15 lbs 6 8 kg with touch screen and base 120 VAC 1 5 A 60 Hz 180 W max FireWorks is modularly listed under the following standards UL 864 categories UOJZ UOXX UL 294 category ALVY UL 636 category ANET UL 1076 category APOU UL 365 category APAW UL 1610 category AMCX ULC S527 and UL 2572 Please refer to FireWorks Installation and Service Manual for complete system requirements Note 2 Supported CCTV Systems Windows XP only Pelco Matrix Systems CM6700 series 8500 9500 Philips LTC8100 8200 8300 8500 8600 8800 8900 series Vicom Nova V142 Kalatel KTD 348 Note 3 Compatible digital alarm receiver is a Bosch D6600 Page 3
10. to perform in re sponse to the event or information about the area where the event has taken place any hazardous materials present in the area etc Access control card holder information images CCTV video audio messages web pages and graphical maps may also be presented to aid in the understanding of an event and how it should be man aged Page 1 of 4 Annunciation 42 Wall Mount Monitor 22 Desktop Monitor A Q AS Vi J 7300 1657 0213 Standard Features e UL ULC Listed for ECS MNS LSS and Security e Event driven configurable multiple viewport display Automatic prioritization of events simplifies the system for the user e Software only versions Where UL listings are not required FireWorks software allows the use of less expensive PCs for monitoring only functions while providing a full featured graphic display e Interactive life safety control e Optional Internet Connectivity Provides remote monitoring of FireWorks status Provides ability to run reports e Monitor and control for single or multi line Life Safety networks e HTTP HTTPS Communications Engine e Email events to multiple recipients automatically e Email events to multiple recipients automatically e Context sensitive event action messages Provides event specific instructional text e Use native graphic formats to create event maps Import most standard graphic formats such as wmf dwg and more e Optional Digital Alarm R