Home

LOGIQ S7 Expert

image

Contents

1. Operator Message Biopsy Guide Line and Zone Heart Rate General System Parameters System Setup Pre programmable Categories User Programmable Preset Capability Factory Default Preset Data Languages English French German Spanish Italian Portuguese Russian Greek Swedish Danish Dutch Finnish Norwegian Japanese message only OB Report Formats including Tokyo Univ Osaka Univ USA Europe and ASUM User Defined Annotations Body Patterns Customized Comment Home Position Complete User Manual available on board through Help F1 User Manual and Service Manual are included on CD with each system A printed manual is available upon request CINE Memory Image Memory 384 MB of Cine Memory Selectable Cine Sequence for Cine Review Prospective Cine Mark Measurements Calculations and Annotations on Cine Playback Scrolling timeline memory Dual Image Cine Display Quad Image Cine Display Cine Gauge and Cine Image Number Display Cine Review Loop Cine Review Speed Image Storage On board database of patient information from past exams Storage Formats e DICOM compressed uncompressed single multiframe with without Raw Data e Export JPEG JPEG2000 WMV MPEG 4 and AVI formats Storage Devices e USB Memory Stick 64MB to 4GB for exporting individual images clips e CD RW storage 700MB e DVD storage R 4 7GB e Hard Drive Image Storage 112GB Compare old images with current exam Reload o
2. Line Density e Scanning Size FOV or Angle depending on the probe see probe specifications e B Colorization e Reject e Suppression e SRI HD e Edge Enhance Digital M Mode Adjustable e Acoustic Power e Gain e Dynamic Range e Gray Scale Map e Frequency e Sweep Speed e M Colorization e M Display Format e Rejection Anatomical M Mode M Mode cursor adjustable at any plane Can be activated from a Cine loop from a live or stored image M and A capability Available with Color Flow Mode Curved Anatomical M Mode Digital Spectral Doppler Mode Adjustable e Acoustic Power e Gain e Dynamic Range e Gray Scale Map e Transmit Frequency e Wall Filter e PW Colorization e Velocity Scale Range e Sweep Speed e Sample Volume Length e Angle Correction e Steered Linear e Spectrum Inversion e Trace Method e Baseline Shift e Doppler Auto Trace e Time Resolution e Compression e Trace Direction e Trace Sensitivity Digital Color Flow Mode Adjustable e Acoustic Power e Color Maps including velocity variance maps e Gain e Velocity Scale Range e Wall Filter e Packet Size e Line Density e Spatial Filter e Steering Angle e Baseline Shift e Frame Average e Threshold e Accumulation mode e Sample Volume Control e Flash Suppression e Quantification Option Digital Power Doppler Imaging Adjustable e Acoustic Power e Color Maps including velocity variance maps e Gain
3. SYS PCCA Systolic Proximal Common Carotid Artery e TCD Transverse Cerebellum Diameter DIAS PCCA Diastolic Proximal Common Carotid Artery esad S4 10 D e THD Thorax Transverse Diameter MUG Rig a o n o SYS DICA Systolic Distal Internal Carotid Artery i o Phased Array Sector Probe e TIB Tibia Length B daia sae ee Endo Micro Convex Probe 2 e ULNA Ulna Length DIAS DICA Systolic Distal Internal Carotid Artery Applications Pediatrics Neonatal Aodomen a Applications OB GYN Urology Transvaginal Estimated Fetal Weight EFW by SYS MICA Systolic Mid Internal Carotid Artery Transrectal Biopsy Guide available None e AC BPD AC BPD FL DIAS MICA Diastolic Mid Internal Carotid Artery Biopsy Guide Single Angle disposable with a e AC BPD FL HC e AC FL a a a l RAB4 8 D e AC FHC e AC HC SYS PICA Systolic Proximal Internal Carotid Artery disposable bracket E8385MJ 8 e BPD APTD TTD FL BPD APTD TTD SL DIAS PICA Diastolic Proximal Internal Carotid Artery oa OREA Convex Volume Probe A and Ratios TU SYS DECA Systolic Distal External Carotid Artery Applications Abdomen OB GYN Urology e FL HC HC AC DIAS DECA Diastolic Distal External Carotid Artery ML6 15 Biopsy Guide Sn naan o AFlAmniotie Flid ind e S a oO reusable bracket H46 01AE CI Cephalic Index Amniotic Fluid Index SYS PECA Systolic Proximal External Carotid Artery Matrix Array Linear Probe single angle reusable H48621Y e CTAR Card
4. curved drawing of M Mode generated from the cursor independent from the axial plane Q Analysis Multiple Time Motion trace display from selected points in the myocardium Stress Echo Option Advanced and flexible Stress Echo examination capabilities Provides exercise and pharmacological protocol templates 8 default templates Template editor for user configuration of existing templates or creation of new templates Reference scan display during acquisition for stress level comparison dual screen Baseline level Previous level selectable Raw data continuous capture Over 100 sec available Wall motion scoring bulls eye and segmental Smart stress Automatically set up various scanning parameters for instance geometry frequency gain etc according to same projection on previous level Virtual Convex Provides a convex field of view Compatible with CrossKBeam Available on all linear and sector transducers SRI HD Speckle Reduction Imaging Provides multiple levels of speckle reduction Compatible with Side by Side DualView Display Compatible with all linear convex and sector transducers Compatible with B Mode Color Contrast Agent and 3D imaging CrossXBeam Provides 3 5 7 or 9 angles of spatial compounding Live Side by Side DualView Display Compatible with e Color Mode e PW e SRI HD e Coded Harmonic Imaging e Virtual Convex Available on 9L D ML6 15 11L D L8 18i D 3CRF D C1 5 D RAB4 8 D
5. disposable with a e a A Multi Angle with a reusable reusable bracket H4906Bk OB Measurements Calculations T bracket H40452LP ENDO Endometrial thickness Sew en rh Gestational Age by tue 8C L8 18i D e GS Gestational Sac A Linear Probe e CRL Crown Rump Length Uterine RI PU OEOD Applications Vascular Small Parts Neonatal r oe a T o ications ascular Small Parts Neonatal a alll Follicular measurements Applications Went PE Pediatrics e BPD Biparietal Diameter c e AC Abdominal Circumference summary Reports Biopsy Guide available None Biopsy Guide available None e HC Head Circumference l e APTD x TTD Anterior Posterior Trunk Diameter by Transverse Vascular Measurements Calculations C1 5 D 3Sp D Trunk Diameter SYS DCCA Systolic Distal Common Carotid Artery Convex Probe e FTA Fetal Trunk Cross sectional Area BIAS DEE EEE E T E Phased Array Sector Probe iastolic Distal Common Carotid Arter aai E oS e HL Humerus Length l y Applications Abdomen Vascular OB Gyn Applications Cardiac Transcranial Abdomen e BD Binocular Distance SYS MCCA Systolic Mid Common Carotid Artery Urology a a ee e FT Foot Length re Biopsy Guide Multi Angle Reusable bracket ae DIAS MCCA Diastolic Mid Common Carotid Artery Biopsy Guide Multi Angle disposable with a H46222LC e OFD Occipital Frontal Diameter EEEE OE ee reusable bracket H40432LE e TAD Transverse Abdominal Diameter
6. 8C and IC5 9 D probes Controls Available While Live Write Zoom B M CrossxBeam Mode Gain TGC Dynamic Range Acoustic Output Transmission Focus Position Transmission Focus Number Line Density Control Sweep Speed for M Mode Number of Angles for CrossKBeam PW Mode Gain Dynamic Range Acoustic Output Transmission Frequency PRF Wall Filter Spectral Averaging Sample Volume Gate e Length e Depth Velocity Scale Color Flow Mode CFM Gain CFM Velocity Range Acoustic Output Wall Echo Filter Packet Size Frame Rate Control CFM Spatial Filter CFM Frame Averaging CFM Line Resolution Frequency Velocity Base Line Shift Controls Available on Freeze or Recall Automatic Optimization SRI HD CrossxBeam Display non compounded and compounded image simultaneously in split screen 3D reconstruction from a stored Cine loop B M CrossxBeam Mode Gray Map Optimization TGC Colorized B and M Frame Average loops only Dynamic Range Anatomical M Mode Max Read Zoom to 8x Base Line Shift Sweep Speed PW Mode Gray Map Post Gain Baseline shift Sweep Speed Invert Spectral wave form Compression Rejection Colorized Spectrum Display Format Doppler Audio Angle Correct Quick Angle Correct Auto Angle Correct Color Flow Overall Gain loops and stills Color Map Transparency Map Frame Averaging loops only Flash Suppression CFM Display Threshold Spectral Invert for Color Doppler Anatomical M Mode
7. GE Healthcare LOGIQ S7 gt gt gt LOGIQ S Expert Amazing versatility Data Sheet 4 N N qe Sensational performance Smart design Specialized capabilities a 4 A gt Product Description The LOGIQ S7 Expert is a highly mobile and easy to use performance multipurpose color Doppler imaging system designed for Obstetrics Gynecology Cardiology Vascular Urology Small Parts Pediatric Neonatal Transcranial and Abdominal applications General specifications Dimensions and weight Scanning methods Height Standard 1750 mm 68 9 in Electronic Sector Tall 1115 mm 43 9 in Electronic Convex Width Keyboard 500 mm 19 7 in Electronic Micro Convex Caster 620 mm 24 4 in Electronic Linear Depth Maximum 856 mm 33 7 in Real Time 4D Volume Sweep Caster 790 mm 31 1 in Weight no Peripherals 90 kg 198 Ibs Transducer types Sector Phased Array Electrical power Convex Array Voltage 100 120 Vac or 220 240 Vac Microconvex Array Frequency 50 60 Hz Linear Array Power consumption maximum of 900 VA with peripherals Matrix Array Single CW Pencil Probes Volume Probes 4D Console design 4 active probe ports 1 non imaging Integrated HDD and DVD R W Operating modes On board storage for peripherals B Mode Integrated speakers Coded H T EE oded Harmonic Imaging M Mode Gel holder warmer Color Flow Mode CFM Power Doppler Imaging PDI PW Doppler with High PRF M Color Flow Mode Anatomical M Mode Front and r
8. al B or CrossxBeam PW Display CW Display Formats e Top Bottom selectable format e Side Side selectable format Virtual Convex Timeline only Display annotation Patient Name First Last and Middle Patient ID 2 Patient ID Age Sex and Birth Date Hospital Name Date format 3 Types selectable e MM DD YY e DD MM YY e YY MM DD Time format 2 types selectable e 24 hours e 12 hours Gestational Age from e LMP e GA e EDD e BBT Displayed Acoustic Output e TIS Thermal Index Soft Tissue e TIC Thermal Index Cranial Bone e TIB Thermal Index Bone e MI Mechanical Index of Maximum Power output Probe Name Map Names Probe Orientation Depth Scale Marker Lateral Scale Marker Focal Zone Markers Image Depth Zoom Depth B Mode Gain Dynamic Range Imaging Frequency Frame Averaging Acoustic Frame Rate Gray Map SRI HD M Mode Gain Dynamic Range Time Scale Doppler Mode Gain Angle Sample Volume Depth and Width Wall Filter Velocity and or Frequency Scale Spectrum Inversion Time Scale PRF Doppler Frequency Color Flow Mode Line Density Frame Averaging Packet Size Color Scale 3 types e Power e Directional PDI e Symmetrical Velocity Imaging Color Velocity Range and Baseline Color Threshold Marker Color Gain PDI Inversion Doppler Frequency TGC Curve Cine Gage Image Number Frame Number Body Pattern Multiple human and animal types Application Name Measurement Results
9. ble ultrasound contrast agents Because the availability of these agents is subject to government regulation and approval product features intended for use with these agents may not be commercially marketed nor made available before the contrast agent is cleared for use Contrast related product features are enabled only on systems for delivery to an authorized country or region of use LOGIQView Option Extended Field of View Imaging Available on 9L D ML6 15 11L D L8 18i D 3CRF D C1 5 D IC5 9 D 3Sp D RAB4 8 D 8C and S4 10 D probes For use in B Mode CrossxBeam is available on linear probes Auto detection of scan direction Pre or post process zoom Rotation Auto fit on monitor Measurements in B Mode 3D Allows unlimited rotation and planar translations 3D reconstruction from Cine sweep Advanced 3D Option Acquisition of Color data Automatic rendering 3D Landscape technology 3D Movie Scan Assistant Option Factory Programs User defined programs Steps include image annotations mode transitions basic imaging controls and measurement initiation Elastography Option Available on ML6 15 9L D C1 5 D IC5 9 D and 11L D probes Semi Quantification TVI Option Myocardial Doppler Imaging with color overlay on tissue image Available on the sector probes Tissue color overlay can be removed to show just the 2D image still retaining the tissue velocity information Curved Anatomical M Mode free
10. e Velocity Scale Range e Wall Filter e Packet Size e Line Density e Spatial Filter e Steering Angle e Frame Average e Threshold e Accumulation mode e Sample Volume Control e Flash Suppression Continuous Wave Doppler Option Adjustable e Acoustic Power e Gain e Dynamic Range e Gray Scale Map e Transmit Frequency e Wall Filter e CW Colorization e Velocity Scale Range e Sweep Speed e Angle Correction e Spectrum Inversion e Trace Method e Baseline Shift e Doppler Auto Trace e Compression e Trace Direction e Trace Sensitivity Automatic Optimization Optimize B Mode image to improve contrast resolution Selectable amount of contrast resolution improvement low medium high Auto Spectral Optimize adjusts e Baseline e Invert e PRF on live image e Angle correction Coded Harmonic Imaging Available on all 2D probes B Flow Option Available on C1 5 D 9L D ML6 15 11L D and L8 18i D probes Background On Off Sensitivity PRI Line Density Edge Enhance Frame Average Gray Scale Map Tint Map Dynamic Range Rejection Gain Dual Beam B Flow Color Accumulation Coded Contrast Imaging Option Available on C1 5 D probe 2 Contrast Timers Timed Updates 0 05 10 seconds AAA LOGIQ S7 P Accumulation mode six levels Maximum Enhance Mode Flash Time Intensity Curve TIC Analysis Auto MI control The LOGIQ S7 Expert is designed for compatibility with commercially availa
11. ear handles User interface Operator keyboard Ergonomic full size keyboard i Curved Anatomical M Mode B Flow B Flow Color Option Extended Field of View LOGIQView Option Coded Contrast Imaging Option CW Doppler Mode Option TVI Mode Option Elastography Option 3D 4D Volume Modes Option Swivel adjustable Height adjustable 8 TGC pods 7 177 8 mm wide LCD touch screen Monitor 19 482 6 mm high resolution LCD Articulating monitor arm System overview y System standard features Applications TEE Advanced user interface with high resolution 7 wide Abdominal Obstetrical LCD touch screen Gynecological Breast Automatic Optimization Small Parts and Superficial Musculoskeletal CrossXBeam compounding Vascular Urological Speckle Reduction Imaging SRI HD Endocavitary Pediatric and Neonatal Fine Angle Steering Transcranial Cardiac Coded Harmonic Imaging Virtual Convex Patient information Database Image Archive on integrated CD DVD and hard drive Raw Data Analysis Real time automatic Doppler calculations OB Calculations Fetal Trending Multigestational Calculations Hip Dysplasia Calculations Gynecological Calculations Vascular Calculations Urological Calculations Renal Calculations Cardiac Calculations Remote capability InSite ExC On board electronic documentation MPEGVue Key Macro Network Storage Quick Save Quick Patient Entry System Options Auto IMT Elastography Elastogra
12. f archived data sets Connectivity amp DICOM Ethernet network connection DICOM 3 0 Optional Verify Print Store Modality Worklist AMA LOGIQ S7 P Storage Commitment Modality Performed Procedure Step MPPS Media Exchange Off network mobile storage queue Query Retrieve Public SR Template e Structured Reporting compatible with vascular and OB standard Remote capability InSite ExC Physiological Input Panel Option Physiological Input ECG 2 lead Dual R Trigger Pre settable ECG R Delay Time Pre settable ECG Position Adjustable ECG Gain Control Automatic Heart Rate Display Report Writer Option On board reporting package automates report writing Formats various exam results into a report suitable for printing or reviewing on a standard PC Exam result reports can include patient info exam info measurements calculations images comments and physician diagnosis Standard templates provided Customizable templates Scanning Parameters Displayed Imaging Depth 0 33 cm Minimum Depth of Field 0 2 cm Zoom probe dependent Maximum Depth of Field 0 33 cm probe dependent Continuous Dynamic Receive Focus Continuous Dynamic Receive Aperture Adjustable Dynamic Range Adjustable Field of View FOV Image Reverse Right Left Image Rotation of 0 180 Digital B Mode Adjustable e Acoustic Power e Gain e Dynamic Range e Frame Averaging e Gray Scale Map e Frequency e
13. in rear AC Power Input Safety Conformance The LOGIQ S7 Expert is Classified to UL 60601 1 by a Nationally Recognized Test Lab Certified to CAN CSA C22 2 No 601 1 M90 by an SCC accredited Test Lab CE Marked to Council Directive 93 42 EEC on Medical Devices Conforms to the following standards for safety e IEC 60601 1 Medical electrical equipment Part 1 General requirements for safety e IEC 60601 1 1 Medical electrical equipment Part 1 1 General requirements for safety Collateral Standard Safety requirements for medical electrical systems e IEC 60601 1 2 Medial electrical equipment Part 1 2 General requirements for safety Collateral Standard Electromagnetic compatibility requirements and tests GE Healthcare 9900 Innovation Drive Wauwatosa WI 53226 U S A www gehealthcare com APAC INDIA T 81 42 585 5111 T 91 80 41801000 CHINA LATIN AMERICA T 86 21 3877 4045 T0800 122 345 EAGM USA CANADA T 9714 4296161 T 1 888 202 5528 or 97144296101 EUROPE T 49 212 28 020 imagination at work e IEC 60601 1 4 Medical electrical equipment Part 1 4 General requirements for safety Collateral Standard programmable electrical medical systems e IEC 60601 1 6 Medical electrical equipment Part 1 6 General requirements for basic safety and essential performance Collateral Standard Usability e IEC 60601 2 37 Medical electrical equipment Part 2 37 Particular requirements for the safety of
14. io Thoracic Area Ratio ee DIAS PECA Diastolic Proximal External Carotid Artery Applications Small parts Vascular Neonatal Measurements Calculations by ASUM ASUM 2001 Berkowitz VERT Systolic Vertebral Velocity Pe Bertagnoli Brenner Campbell CFEF Chitty Eik Nes Ericksen me A Pen Goldstein Hadlock Hansmann Hellman Hill Hohler Jeanty SUBCLAV Systolic Subclavian Velocity Biopsy Guide Multi Angle disposable with a CW Split Crystal Probe COC reusable bracket H40432LJ ae JSUM Kurtz Mayden Mercer Merz Moore Nelson Osaka Automatic IMT Applications Cardiac Pediatric University Paris Rempen Robinson Shepard Shepard Warsoff Tokyo University Tokyo Shinozuka Yarkoni summary Reports 11L D P6D Fetal Graphical Trending Linear Probe Urological Calculations Vascular Small Parts Neonatal CW Split Crystal Probe Pediatrics Applications Cardiac Pediatric Vascular Biopsy Guide Multi Angle disposable with a reusable bracket H40432LC Growth Percentiles Applications Bladder Volume Multi Gestational Calculations 4 Prostate Volume Fetal Qualitative Description Anatomical survey St Renal Volume Fetal Environmental Description Biophysical profile Generic Volume _Programmoble OB Tables 222 Post Void Bladder Volume Over 20 selectable OB Calculations Expanded Worksheets Inputs and Outputs HDMI Out Ethernet Network RJ45 External Audio Out USB 2x in front 1x
15. on Cine loop NNS LOGIQ S7 P Measurements Calculations General B Mode Depth and Distance Circumference Ellipse Trace Area Ellipse Trace Volume Ellipsoid Stenosis Area or Diameter Angle between two lines General M Mode M Depth Distance Time Slope Heart Rate General Doppler Measurements Calculations Velocity Time A B Ratio Velocities Frequency Ratio PS Peak Systole ED End Diastole PS ED PS ED Ratio ED PS ED PS Ratio AT Acceleration Time ACCEL Acceleration TAMAX Time Averaged Maximum Velocity Volume Flow TAMEAN and Vessel Area Heart Rate PI Pulsatility Index RI Resistivity Index Real time Doppler Auto Measurements Calculations PS Peak Systole ED End Diastole MD Minimum Diastole PI Pulsatility Index RI Resistivity Index AT Acceleration Time ACC Acceleration PS ED PS ED Ratio ED PS ED PS Ratio AMA LOGIQ S7 P Probes GYN Measurements Calculations 3CRF D 9L D HR Heart Rate Right Ovary Length Width Height Micro Convex Biopsy Probe Urea Probe TAMAX Time Averaged Maximum Velocity Left Ovary Length Width Height Applications Abdomen OB GYN Urology Applications Vascular Small Parts Pediatric PVAL Peak Velocity Value Uterus Length Width Height Biopsy Guide Single Angle disposable with Abdomen Volume Flow TAMEAN and Vessel Area Cervix Length Trace a reusable bracket 40442LR Biopsy Guide Multi Angle
16. phy Q Analysist Advanced 3D DICOM 3 0 Connectivity LOGIQView B Flow B Flow Color CF PDI Quantification B Steer Stress Echo Tissue Velocity Imaging TVI with Q Analysis Scan Assistant Report Writer Coded Contrast Imaging ECG AHA IEC Cables CW Doppler DVR Kit Real Time 4D 4D TUI VOCAL VCI Static AMA LOGIQ S7 P Cabinet High Mid Low Drawer Small Probe Adaptor Vertical Endocavitary Probe Holder Side Probe Holder Probe Cable Hanger 3 Pedal Foot Switch Isolation transformer Peripheral Options Integrated Options for e Digital BW thermal printer e Digital A5 Color thermal printer e DVD video recorder Digital A6 Color thermal printer External USB printer connection HDMI output available for compatible devices Foot Switch with programmable functionality Console Protective Cover Display modes Live and Stored Display Format full size and split screen both with thumbnails for still and Cine Review Image Format 4x4 and thumbnails for still and Cine Simultaneous Capability B or CrossxBeam PW B or CrossxBeam CFM or PDI B M B CrossxBeam Real time Triplex Mode B or CrossxBeam CFM or PDI PW or CW Option Selectable alternating Modes B or CrossxBeam PW B or CrossxBeam CFM PDI PW CW Option B CW Option Multi image split quad screen Live and or frozen B or CrossXBeam B or CrossxBeam CFM or PDI Independent Cine playback Time line display Independent Du
17. ultrasonic medical diagnostic and monitoring equipment e ISO 10993 1 Biological evaluation of medical devices Part 1 Evaluation and testing e NEMA UD2 Acoustic output measurement standard for diagnostic ultrasound equipment e NEMA UD3 Standard for real time display of thermal and mechanical acoustic output indices on diagnostic ultrasound equipment MI TIS TIB TIC EMC Emissions Group 1 Class B device requirements as per Sub clause 4 2 of CISPR 11 Elastography with semi Quantification Elastography Q Analysis described in this material has not been cleared by the U S FDA and is not available for promotion or sale in the United States Coded contrast imaging described in this material has not been cleared by the U S FDA and is not available for promotion or sale in the United States 2012 General Electric Company All rights reserved General Electric Company reserves the right to make changes in specifications and features shown herein or discontinue the product described at any time without notice or obligation Contact your GE Representative for the most current information GE and GE Monogram are trademarks of General Electric Company GE Medical Systems Ultrasound amp Primary Care Diagnostics LLC a General Electric company doing business as GE Healthcare Trademark of General Electric Company DOC1134676