Home
LXS AWL MIOL-B System Operation and Maintenance ma
Contents
1. E mail info luxsolar com Page 20 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING CONNECTIONS J Optional Input LN tH T v SINCRO FAIL INPUT 7 59 N COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 21 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING MAIN DATA OUTPUT VOLTAGE No Load Max output voltage 210 VDC With Load Max Output working voltage 150VDC Self Protected circuit against LED reverse polarity connection Self Protected circuit against LED short circuit Auxiliary Alarm Relay de energized for alarm or no power Protection Fuse 5x20 3 15 AT on inlet phase Synchronizations flash output available via AC Net For 115Vac application add autotransformer input 115Vac output 230Vac optional Continuous power supply 100 130 V dc for max 60W dip switch 1 amp 2 must be set at 0 200 260 Vdc for max 150W Inrush current select D curve as for motor starter or delayed fuse f the AT150 electronic is powered without LEDs connected the AT150 will enter in safe mode within 500ms than no power will be available at LED o
2. MIOL B MIOL C Order code 4 5 L864 LXS Series 200 Manufacturer code Visible light infrared LEDs Flashing B B Base Steady burning C W Wall Single light S SUM S Side Twin light T R Remote PSU 180 1 L Local PSU 360 2 SIDE VIEW TOP VIEW PELL Ke amp T a 17 8 yoy Le N a HORIZONTAL VERTICAL LEVEL ADJUSTEMENT SCREWS 3 LEVEL INDICATOR FIXING PLATE rev 01 COMBUSTION AND ENERGY info Iuxsolar com www luxsolar com Ph 39 0341 260926 LXS S COMBUSTION AND ENERGY SRL Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 5 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 2 OVERVIEW The beacons are pre assembled in factory and can operate with their own power supply circuits The necessary power feed the beacon is 1 10 of the power needed for the same beacon incandescent type This manual has to be read and understood before doing maintenance on the system or doing the start up For the system functioning and first start up please refer to document F A T included in the data book Each lamp has a special breathing valve to prevent moisture presence This device Equalizes pressures to pr
3. N En fe COMBUSTION AND ENERGY SRL ES P Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 23 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 10 MAINTENANCE AWL beacons maintenance has to be done in accordance with ICAO rules Airport Service Manual Part 9 Airport Maintenance Practices 1984 par 2 6 Light Maintenance Procedure Maintenance procedure can be resumed as follow 1 AWL beacons cleaning intervention Dust and sand brought by wind to the beacons offen reduce the intensity of the light so they have to be removed The same thing has to be done for water left on the glass by bugs For this reason every two months it is necessary to clean the Beacons glass with water and suitable fluids Pay attention Do not use corrosive or oily products If there will be meteorological phenomenon with dust the beacons cleaning is required 2 Damaged beacon replacement As soon as the broken beacon is detected replace it immediately with a new one Do not try to repair it on quote test and repair the beacons only in laboratory 3 Periodic check Climatic conditions lens degrade and the reduction of the intensity emitted from light source are the causes of possible reduction of the intensity of AWL beacons ICAO rules provide that if the
4. info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 11 TROUBLESHOOTING Very important Some of the tests below have to be done with live system For this reason they should only be undertaken by qualified experienced personnel familiar with the equipment involved Preliminary tests to be done without power supply Verify the interconnection cables installation correct pins bolts tighten etc Verify that all green connectors on all electrical devices inside the panel are fixed correctly to the related electronic boards Verify that all the fuses integrity Verify that all the automatic switches are in ON position Verify that the system receive 230Vac power supply or 24Vdc as option Verify if black burnt mark are present on electrical components Please find here below some fault conditions with dedicated solution All the operations that require repolacement of components have to be done without power supply Fault all MIOL C beacons are off Probable causes there is no electrical power supply to the system automatic switches into off position main switch into O position fused terminals open Solutions give power supply to the system turn automatic switches into on position turn main switch into 1 position close fused terminals Fault one MIOL AC or MIOL C beacon is in fault condition Proba
5. 39 0341 260926 COMBUSTION AND ENERGY SRL Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 3 of 33 rev 2 00 info ce2k com www luxsolar com WWNW Ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl gt QS LUXSOLAR LUXSOLAR AERONAUTICAL LIGHTING AIRCRAFT WARNING LIGHTS MIOL B MIOL C KEY FEATURES Based on LED technology e 2 000 cd night mode RED flashing for MIOL B e 2 000 cd night mode RED steady burning for MIOL C Long life time gt 10 years life expectancy Low consumption Stabilised light output Lightweight and compact Low wind load factor Alarm remote status control Easy to install No RF radiations Light output alignment device Patented beacon EU 001929910 0001 Canada 145 189 USA D673 474 OPTICAL FEATURES Cd emission 0 5 and 4 Horizontal beam radiation 360 Vertical beam spread 4 PMMA lens OPTIONS Twin version two galvanically separated circuits in the same fixture Anti bird protection Beacon support bracket Power supply AC or DC GPS Global Position System syncro Infrared available ELECTRICAL FEATURES e Average power consumption for MIOL B e20fpm 9W e Average power consumption for MIOL B e40fpm 12W e Average power consumption for MIOL B 60fpm 15W e Average power consumption for MIOL C steady burning 54W
6. LUXSOLAR AERONAUTICAL LIGHTING LED1 and LED2 refer to the power supply circuit so once the system is power supplied they have to be on and fixed Instead LED3 refers to the output so in this case we have three conditions Normal operation if is on and it flashes according to the MIOL B lamps The flash of all LED3 leds is synchronized Faulty operation it is on and it flashes very fast with very weak light The flash is not synchronized with the other LED3 leds Third condition it is off because it refers to an electronic board that doesn t have to work in the current mode for example a day board during night Once the fault condition is detected please contact our technical office by phone or email for further assistance Electronic board PSU regulatory compliance The AT 150 LXS LED DRIVER PSU is designed to allow the Warning Beacons to comply with ICAO rules and FAA EASA specifications The AT 150 LXS LED DRIVER PSU is designed according to the directive 2004 108 EC Electromagnetic Compatibility the conformity is given by the compliance of the following Europen Standards EN 61547 Lighting devices EMC immunity EN 61000 3 2 EMC Part 3 2 EMC limits for current 16A on each phase CEI EN 55015 limits for radioemissions on lighting 2006 95 EC Low Voltage Directive the conformity is given by the compliance of the following Europen Standards EN 61347 1 Lamp Controlgear part 1 general and safety requirements
7. code ATB150 LXS for 230Vac or ATC150 LXS for 24Vdc LPS components in the drawings These boards make the LEDs flashing and they also check the lamp status They work all together only during the day and they are divided as per below Electronic boards LPS 1 2 3 work only during night mode They have Nr 08 DIP switches and the correct configuration is the following For all LPS 1 2 3 2 7 0 8 OFF a DIP A43 ON The electronic board check continuously the beacon status and in case of fault it switches on automatically the fault signalling lamps and the fault contact The fault condition is activated even if only one of the two boards detect a fault condition In addition They have a glass fuse on the input circuit They have the input circuit electrically insulated from the output one They have an input They are protected against reverse connection They are protected against LED short or open circuit Once the system detect fault condition it is possible to understand visually which is the electronic board in this condition Please refer to the highlighted LEDs on the picture below be COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 17 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl
8. A N A 10 Table 6 2 fixed obstacle ee Yellow Blue Flashin ES Tu d 40 40 Table 6 2 mobile obstacle P Low intensity Type B fixed obstacle Low intensity vehicle LE ENF ame ees ES Type c High intensity Flashing _ lice White 40 60 fom 200 000 20 000 2 000 Table 6 3 High intensity Flashing k Type B White 40 60 fom 100 000 20 000 2 000 Table 6 3 Document extract from ICAO Annex 14 Aerodromes Volume Table 6 1 Characteristics of obstacle lights COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 7 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING As you can see there are three big categories of lights low medium and high intensity type The differences are related to the intensity of lights colours flashing or fixed and when the lamps are on or off during the day night Some combinations of lights are also possible for example medium intensity AC In this case the lamp will be white flashing during the day and red flashing during the night If the lamps are flashing type and installed on the same structure they have to be synchronized On the light intensity of medium and high lamps type there is a tolerance of 25 be COMBUSTION AND ENERGY
9. AVAILABLE COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 15 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 8 AWL SYSTEMS OPERATIONS The AWL system is designed to work for night mode only During normal operation all the MIOL B beacons are flashing accordingly to the light condition It is power supplied with 230Vac 50 60Hz voltage 1 phase neutral or 24Vdc as option The voltage have to be sinusoidal in Vac version only so no square UPS input voltage nor diesel generator type are allowed There are Nr 02 functional modes of the system Day mode all MIOL B beacons are switched OFF Night mode all MIOL B beacons are flashing with 2 000cd intensity The changing from all of these modes is made automatically by the system through the twilight sensor This device has to be installed in a safe area where artificial light is not present avoid false reading It detects the light difference between day and night so it switches the system into the correct mode During tests phase or commissioning it is possible to force the mode condition by covering or illuminating the sensor The sensor has an hysteresis of about 1 minute on the reading so the change is not immediate For the start up
10. SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 8 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl e LCS LUXSOLAR LUXSOLAR AERONAUTICAL LIGHTING 4 MIOL B LAMPS EMISSION TESTS The Medium Intensity Obstruction Lights MIOL for these systems are B type with 360 radial emission This means that they have the following intensity Switch off during daytime 2 000cd red flashing during night time Reference code number L864 LXS B Night mode red flashing Minimum Maximum Measured Intensity cd 2177 3 479 Emission cd 2600 2400 2200 2000 1800 1600 1400 1200 1000 800 600 400 200 10 8 6 4 2 0 2 4 6 8 10 Vertical Angle COMBUSTION AND ENERGY SRL Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 5 SAFETY NOTICE DANGER ELECTRICAL VOLTAGE The AWL system associated with the supplied equipment uses 230Vac as option 24Vdc and 170Vdc voltage to supply the beacons This voltage is present all the AWL panels and also inside alll the beacons In addition some components inside the AWL panels c
11. fa fede Capziano del Colle 30 07 2013 i i e 2 Ing Michele Peschiera Testing engineer Full report is available under request 13 WARRANTY be COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 32 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING LUXSOLAR Warranty Obstruction Lighting C amp E srl Luxsolar warrants the purchaser and the final user of AWL LED beacons Luxsolar that at the moment of their purchase the products were exempt of shortages and conform with ICAO Annex 14 requirements 3 years warranty for materials and labor For a period of five years from the purchase date Luxsolar at its unchallengeable opinion provides to repair or replace lacking product directly or through other companies and people Warranty is applicable only in case of factory default or assembly default 3 years warranty for light degradation For a period of five years from installation date Luxsolar at its unchallengeable opinion provides repair or replace directly or through other companies and people the product having a light intensity 776 lower than the intensity required according to ICAO Annex 14 June 2004 rules Warranty does not cover 1 advice or information complementa
12. light intensity is reduced under the 50 of the specified value it is necessary the replacement of the beacon By the way It is strongly prompted to replace the beacon if the light intensity is less than 70 A simple light sensor used overnight can indicate the light intensity value that has to be compared with the ICAO one The optimum working period of AWL beacons LED type can be define in 5 years before beacons replacement be COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 24 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING MAINTENANCE MODULE Please send us this report every six months starting from bill of materials date at Luxsolar by fax nr 39 0341 577747 Others way of sending will not be considered The compilation of this module is necessary for the warranty Date OT document aff x Peronin ODDO CIE COPS _ REDON State of functioning and preservation Very good Good Damaged Device MIOL C LED beacons Control panels Internal wiring Twilight sensor Interconnection cables COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 25 of 33 rev 2 00
13. z tema ottico non Campo di frequenze 10 1 50Hz stacchi o danneggi picco picco 22 mm Ampiezza 60 m N 10 zu asse verticale Velocit cielo oct min Campione non almentszto durante la prova be COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 31 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 597 OL14 RO1 ver 0 Applicant COMBUSTION AND ENERGY SRL Via Dolzago 21 23848 Ogsiono LC Italia EUT Type MIOL AB L864 865 LX 5 200 EN 60068 2 6 2008 Frequency range 10 150 Hz peak to peak Amplitude 30 mm Amplitude 80 m s N 10 sweep on Vertical axis Visual inspection checking for Sinus Vibration 1 oct min sweep sate detachment of the optical system Vibrazione sinusoidale Sample not powered ducing test I pezione visiva veri amp ca che il wstema ottico non Campo di equenze 10 1 50Hz stacchi danneggi amp ezza picco picco 30 mm Ampiezza 80 m N 10 celi verticale Velocit ciclo oct min Campsone non alimentato durante la prova The Test Report comprises 6 pages The English version s the only official version of this test report Questo rapporto di prova contiene 6 pagine La versione inglese di questo rapporto di prova e l unica versione ufficiale che
14. 23848 Ossiono LC Italia EUT Type MIOL AB L864 865 LX 5 200 TEST AND RESULTS PROVE E RISULTATI Identi amp cazione prova Procedura di prova Requisito di prova Esito EN 60068 2 6 2008 Frequency range 5 150 Hz peak to peak Amplimde 7 5 mm Amplitude 20 m s N 10 sweep axis Vertical transversal and longitudinal nT NE COENE A dedic n a S MCN ENT ias dn detachment of the optical system Vibrazione sinusoidale ee Sample not powered during test I pezione visiva veri amp ca che il z tema ottico 1 stacchi o danneggi Campo di Eequeaze 5 190 PASS EN 60068 2 6 2008 Frequency range 5 150 Hz peak to peak Amplitude 15 mm Amplitude 40 m s N 10 sweep on Vertical axis Visual inspection checking for Sinus Vibration 1 oct min sweep rate detachment of the optical system PASS Vibrazione simusoidale Sample not powered during test CONFORME PASS I pezione visiva veri amp ca che il z tema ottico Campo fequenze 5 155 stacchi o danneggi arupaezza picco picco 15 mm Ampiezza 40 m s N 10 Geli asse verticale Velocit ciclo 1 oct mun Campione non alimentato durante la prova EN 60068 2 6 2008 Frequency range 10 150 Hz peak to peak Amplitude 22 mm Amplitude 60 m s N 10 sweep on Vertical axis Visual inspection checking for Sinus Vibration 1 oct mun sweep sate detachment of the optical system Vibrazione sinusoidale Sample not powered during test I pezione visiva veri amp ca che il
15. EN 61347 2 13 Lamp Controlgear part 2 13 Particular requirements for d c or a c supplied electronic controlgear for LED modules Combustion and Energy srl as manufacturer of AWL beacons and relevant Driver Circuits declares to operate in accordance with EN ISO 9001 2000 cert nr IQ 1200 15 and 89 392 CEE 91 368 CEE 93 AA CEE 93 68 CEE directives Combustion and Energy srl as manufacturer of AWL beacons and relevant Driver Circuits inform that the above part of devices can not be in service before that the full device on which it will be incorporated as to be declared in conformity to the rules 89 392 CEE be COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 18 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING PSU LAYOUT LLG 03 5 N COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 19 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING FIXING POINT FOR RACK MODE 135 N COMBUSTION AND ENERGY SRL Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926
16. LUXSOLAR AERONAUTICAL LIGHTING AWL AIRCRAFT WARNING LIGHT MIOL B TYPE OPERATION AND MAINTENANCE MANUAL be 9 COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com infoGce2k com Web www luxsolar com www ce2k com LUXSOLAR IX and LUXSOLAR are trademarks of Combusfi LUXSOLAR AERONAUTICAL LIGHTING INDEX e MIOL B Datasheet ordering code weight and dimensions Overview ICAO rules general concepts type of lamps MIOL lamps light emission tests Safety notice Typical general layout and system description Fixing details AWL systems operation Ie D Se dew e Fault detection electronic boards details and setting O Maintenance Troubleshooting MIOL B tests ICAO certification IP65 test Vibration test Climatic test report CO N Warranty be COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 2 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 1 MIOL B DATASHEET AIRCRAFT WARNING LIGHTS MEDIUM INTENSITY OBSTRUCTION LIGHT MIOL B MIOL C e LCS LUXSOLAR rev 01 COMBUSTION AND ENERGY info luxsolar com www luxsolar com Ph
17. ble causes there is no electrical power supply to the lamp one or more electronic board are in fault damaged LEDs inside the beacon wrong interconnection Solutions give power supply to the lamp replace the electronic board replace the beacon change the interconnection be COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 26 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 12 MIOL B TESTS ICAO CERTIFICATION IP65 TEST VIBRATION TEST CLIMATIC TEST REPORT ICAO TEST REPORT MINISTERE DE L COLOGIE DU DEVELOPPEMENT DURABLE ET DE L ENERGII Libert Frareraie REPUBLIQUE FRANGAISE CERTIFICATE OF COMPLIANCE Aeronautical ground lighting N 2014A018 Cancel and replace the certificate 2013A037 issued on 7th june 2013 For the following ground lightinc Medium intensity obstacle light type B Luxsolar Name L864 LXS CG B Power supply 230V AC Red 20 C 45 C Issued to Combustion and Energy SRL Temperature range Referring to the obstacle lighting requirements PRO STAC SE VIS 6003 V4 25 01 2013 By Service Technique de l Aviation Civile 23 September 2014 This certificate of compliance is only issued for the ground lighting d
18. e Nr 0 Base AWL Panel Nr 0I Twilight Sensor AT top level Nr O1 or 03 or 04 MIOL B beacons depend of the shape and diameter of the structure In the next page it is shown the typical interconnection diagram of the systems For further details please refer to the dedicated electrical drawing MIOL C1 MIOL C2 MIOL C3 MIOL C4 en TE AE TE MAIE AE TAE LEVEL Nr 04 MIOL C POWER SUPPLY CABLES 362 5sqmm gt D Be aE AWL CONTROL PANEL 5 or 2 ALARMS SIGMALS 16x1sqmm BY CLIE COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 11 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING CABLE GLANDS POLYAMIDE TYPE SINGLE SEAL INSTALL PROTECTED BY WEATHER CONDITIONS BOX MATERIAL CARBON STEEL PAINTING COLOUR RAL7035 DEGREE OF PROTECTION 1 65 NOTES p 2 w cable s w cable gland M25x1 5 MIOL C POWER SUPPLY CABLE AWL JB8 001 AWL CONIROL PANEL EXIERNAL LAYOUT JWE w cable gland M16x1 5 S ore w cable gland M25x1 5 Il stotnmoun N COMBUSTION AND ENERGY SRL Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 12 of 33 rev 2 00 info ce2k com Web www
19. e LED feeded at constant current e Lightning protection LXS MECHANICAL FEATURES e Anodised aluminium body with heat sink for natural draft air cooling e RAL7035 painted aluminium body lamp e Bottom wind collector for central heat sink cooling Borosilicate glass cover protection Silicon gasket Degree of protection IP66 Operating temperature 45 C to 55 C Storage temp range 45 C to 55 C Lamp unit weight 3 5kg APPLY TO e Airport Stack High building Chimney Tower crane Pipe line Bridge Radio and television Tower e Transmission line Wind turbine Wind mast measurement e Radar Antenna INTERNATIONAL REGULATION e ICAO Aerodromes Annex 14 Volume 1 6 Edition July 2013 Chapter 6 Medium intensity Type B flashing obstacle light MIOL B type or Type C steady burning obstacle light MIOL C type e FAA AC150 5345 43F 67 Lamp type L 864 or Twin L 864 e DGAC STAC approval 2013A037 e CE marking info luxsolar com www luxsolar com Ph 39 0341 260926 COMBUSTION AND ENERGY Document is subject to change without any notice COMBUSTION AND ENERGY SRL Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com info ce2k com Web www luxsolar com www ce2k com LXS and LUXSOLAR are trademarks of Combustion and Energy Srl rev Ol Page 4 of 33 rev 2 00 LUXSOLAR AERONAUTICAL LIGHTING AIRCRAFT WARNING LIGHTS
20. escribed above Any oher ground lighting resulting from any changes fo this latter must be submitted to the STAC approval aboratoire photometrief 2aviation civile gouv fr www stac aviation civile gouv fr Full report is available under request SN COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 27 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING IP65 TEST REPORT TEST REPORT IPTR 140870 0 PR Degrees of protection provided by enclosure IP code RICERCA amp SVILUPPO Degrees of protection against solid foreign object Model and or type reference Aircraft Warning Lights beacons TEST CONDITION Ambient temperature l EN 2I Test means Dust Chamber Depression z2U0mBar Duration of test B hour ingress of dust inside the enclosure Date of issue 2014 07 11 page 9 of 16 N N COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 28 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING TEST REPORT IPTR_140870 0 PR Degrees of protection prov
21. he implicit warranty of commercial use and suitability for other uses Damage limitations Under no circumstances LUXSOLAR will be liable for incidental or accidental damages and loss of profits or savings suffered by purchaser or third part that may be caused by its products or by failure of its products This limitation will be effective even if damage and loss have been caused by Luxsolar or its representative s negligence and even if Luxsolar is informed about the possibility of such damages and losses This limitation of liability may not apply to damages relating to personal injury or death in jurisdictions where such damages may not be disclaimed as a matter of law To obtain warranty service user has to ask by fax 39 0341 577747 and obtain the authorization return number of material ARM from Luxsolar Service Centre be COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 33 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl
22. ided by enclosure IP code RICERCA amp SVILUPPO Degrees of protection against water Model and or type reference Aircraft Warning Lights beacons Testing location Prima Ricerca amp Sviluppo Via Boscone 68 22077 Olgiate Comasco CO Italy 2014 02 11 Mo ingress of water inside the enclosure Date of issue 2014 07 11 page 12 of 16 Full report is available under request N N COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 29 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING VIBRATION TEST REPORT 597 OL14 RO01 ver 0 Applicant COMBUSTION AND ENERGY SRL COMBUSTION AND ENERGY SRL Via per Dolzago 21 23848 Oggiono LC Italia Qualilab s r l Via Trento 87 25020 Capziano del Colle BS Ver 0 30 07 2014 Aircraft Warning Lights beacons oec Modelio The test results and observation indicated in this test report refer exchasively to the sample tested It is not pezmutted to transfer the results to other system oc configuration The publication or duplication of this test report with enclozuze or Part of this test report oc enclosures without a written consent of the test laboratory i not permitted The test laborato
23. luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING e LCS LUXSOLAR NEL r AWL CONTROL t t t T ci ci c c 2 nu af Ins Li in Al i F POEs O COMBUSTION AND ENERGY SRL Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 13 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 10 H0 10 H0 e cs S u EC E O Hwiha tt II L L J M O iz d il ga l tl MIOL XM r e BOX MCl1 AWL JB 001 AWL CONTROL PANEL be COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 14 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 7 FIXING DETAILS Each beacon can be fixed to the structures in difference way see details below MEDIUM INTENSITY TYPE B L864 LXS B BASE TYPE INSTALLATION SIDE TYPE INSTALLATION FRONT VIEW 225 BOTTOM VIEW WITHOUT WIND COLLECTOR TYPES
24. ontain capacitors that will retain their charge for several minutes after the main power has been switched off To avoid risk of injury we recommend the following precautions Maintenance should only be undertaken by qualified experienced personnel familiar with the equipment involved After isolating the power supply wait at least 5 minutes before opening the panel This allows the capacitors to drain their charge Ensure the system is electrically isolated before attempting maintenance on cables DANGER HIGH BRIGHTNESS Do not look directly the light source LED during system functioning Considering the high brightness of this source there is an high risk to be dazzled and or to have temporary or permanent sight injury If during maintenance it will be necessary to leave the light on it will be mandatory to use adequate protection glasses for the whole time N COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 10 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 6 TYPE GENERAL LAYOUT AND SYSTEM DESCRIPTION MIOL B AWL systems is used when the structure 15 lower than 105m The lights are installed on the top of the structure RED AND WHITE MARKED and composed of the following material At base structur
25. otect housing enclosures and seals Prevent contamination to protect electronics Reduce condensation to protect against corrosion Q Ir passes K through the membrane qu Liquid and Water vapor molecules particles pass through the membrane are repelled SN COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 6 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 3 ICAO RULES GENERAL CONCEPTS TYPE OF LAMPS Rules Reference ICAO International Standards and Recommended Practices Annex 14 Aerodromes Volume Aerodrome Design and Operations sixth edition July 2013 ICAO Aerodrome Design Manual Part 4 Visual AIDS fourth edition 2004 ICAO Airport Service Manual Part 9 Airport Maintenance Practices 1984 par 2 6 Light Maintenance Procedure The Aircraft Warning Lights AWL beacons are designed in accordance to ICAO rules These rules define the all the optical characteristics of the lights the number to be installed and the allowed configurations Please refer to the table below Peak intensity cd at given Background Light Type Colour Type bindhee 2 Distribution flash rate Day Above Twilight Night Table 500cd m 50 500cd m Below 50cd m Low intensity Type A N
26. please refer to the step by step instruction included in the FAT document Each MIOL B beacon is power supplied with Nr 01 electronic boards code ATB150 LXS for 230Vac inlet or ATC150 LXS for 24Vdc inlet LPS components in the drawings These boards make the LEDs steady burning and they also check the lamp status For further details please refer to next Section 9 Once the system has been switched on and tested it works automatically using the twilight sensor so it is not necessary to change the mode status manually In case of system with multiple light on the AWL Control Panel can be installed fault status lamps one for each beacon or fault beacon level Inside the panel there are also fault signal contacts again one for each lamp When all the beacons are working correctly the signalling lamps are off and the contact are closed Instead if one or more lamps are faulty the corresponding signalling lamp switches one while the contact opens For further details please refer to next Section 9 be COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 16 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 9 FAULT DETECTION ELECTRONIC BOARD DETAILS AND SETTING Each MIOL B beacon is power supplied with Nr 01 electronic boards
27. ry given by Luxsolar 2 assembly and disassembly of products 3 Fault or lacks caused by accidents modifications wrong use environment temperature gt 55 C voltage value higher than the indicated one wrong maintenance abuse wrong installation and wrong storage Warranty conditions 1 The user has to communicate and detail the shortage or the reduction of light intensity before the end of the warranty period 2 Ship the product with a copy of the purchase order and the name of the original purchaser 3 The user has to pre pay all shipping costs including insurance from plant to Luxsolar and from Luxsolar to plant for repaired and or replaced parts 4 Luxsolar is authorized to detain repaired replaced parts 5 every six months starting bill of material s date User has to send the maintenance module entirely compiled to Luxsolar service center exclusively by FAX no 39 0341 577747 If this module will not be sent warranty will not be applied to repair replacement Warranty limitations this warranty will not cover other suppliers products All the replaced repaired products will be covered by warranty only for the remaining warranty period The replaced products will not be necessarily identical to original ones though having the same functionality Repairs replacements or compensations are the only remedies agreed by this warranty Luxsolar declines any other kind of warranty included without limitations t
28. ry not assumes any lability to party for any loss expense or damage occasioned by the use of this report Any use of the laboratome mame or one o its mark for the sale oc advertisement of the tested matezial product or service amst amp r t be approved in wrtmg by the test laboratory I dsultati e le osservazioni indicate in questo apporto di prova sono zifente evclusivamente 2 campioni testati Non permesso utilizzare i coultat e le osservazioni d questo apporto di prora per aitri ziztenx o configurazon Noa permessa la pabbicazone o la dupheazione completa o parziale di questo apporto d prora e dei suoi allegati senza un consenso scritto da parte del laboratode di prova laboratodio di prova non zi assume responsabilit nei confronti di terzi per danni o eventuali costi degvanti dall utilizzo dei dati presenti questo rapporto di prova Ogui uso del name del labonatono di prova e dei marchi per l vendita o pubblicizzare il prodotto testato deve essere prima approvato in forma zezitta dal labomtono di prora be COMBUSTION AND ENERGY SRL by Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 30 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING 597 OL14 RO1 0 Applicant COMBUSTION AND ENERGY SRL Dolzago 21
29. utput even if LED are reconnected To feed the LEDs please disconnect power supply wait at least 2 seconds and reconnect power supply The ATI50 has been designed to be connected to expansion card for dimmering and for communication be COMBUSTION AND ENERGY SRL ES Via per Dolzago 21 23848 Oggiono LC Italy Ph 39 0341 260926 E mail info luxsolar com Page 22 of 33 rev 2 00 info ce2k com Web www luxsolar com www ce2k com LUXSOLAR LXS and LUXSOLAR are trademarks of Combustion and Energy Srl LUXSOLAR AERONAUTICAL LIGHTING PSU CARD Dip Switch setting Function Jumper Note 0 0 Output for MIOL B amp 1 0 Output not to be used O Output not to be used Output for MIOL A multiple cards are required 0 Automatic Syncro 2 External Syncro 0 Flashing light internal or external syncro 1 Steady burning light bypass syncro 0 0 Not to be used 1 O 200mS ramp 14 mA msS 0 3 Not to be used 3 Not to be used 0 0 Frequency flashing 20 flash min 1 0 Frequency flashing 40 flash min 1 Frequency flashing 50 flash min 3 Frequency flashing 60 flash min 0 Normal functionality Acquisition Aux signal during the start 1 Only for flashing selection if steady burning set current will be automatically reduced 2 Dip switch 7 amp 8 will not be readied if external syncro is selected 3 Not applicable for MIOL A if set curent will be automatically reduced V
Download Pdf Manuals
Related Search
Related Contents
Trust Laser Mouse MI-6950R Nーー ネッ トワークの憂用について 2月 5 日 (金) よ り, 九州大学, 北海道 DWZ-M50/DWZ Sony XM-1002-HX Marketing Specifications H201-K-Frame User Manual Modulare System Management Konsole Modular System User's gUide User's gUide WARRANTY SUMMARY Period of Coverage Labour :6 Copyright © All rights reserved.