Home

07 Electrosurgery 2007

image

Contents

1. to 75dBA e tact with the patient The alarm is signalled b ca see contact wi e patient The alarm is signalled by an E moutmitavannine intermittent beep together with a flashing red light on the Split or not split patient plate allowed front panel In this condition HF emission for cut and Last working condition storing Electrical Class EN60601 1 MDD 93 42 EEC Class Patient circuit Conform to EN60601 1 4 1998 E e a a ioral OVT Alarm The unit includes an internal circuit protection Kit of 6 short autoclavable electrodes diam 2 4 mm warning when the current delivery lasts too much long User manual available in English Spanish Italian French Polish Code 27139 DIATERMO NYLON BAG black See page 25 coagulation operation is switched off Diatermo MB 122 MB 160 standard accessories MB single use two button handles MB operative foot switch usable as alternative to handle FOOTSWITCHES AND BOARD It allows selection from pedal of CUT and COAG functions GIMA Antiexplosion and waterproof Footswitches for MB 122 132 160 200 202 30568 Standard footswitch on o5 Waterproof MB footswitch Doub es a S S S 30557 Main board specify model and serial number of diatermo with order 84 on o h We GUNNA ELECTROSURGERY Diatermo MB 200 and MB 202 mono bipolar 200 DIATERMO MB 202 g g g Skin Plate asa Re HEN Electronic Control Code 30542 DIATERMO MB 200 200 Watt
2. 12 months accessories not included Norms IEC 601 2 2 IEC 601 1 CE 93 42 EEC Coag output 80W 0 5 kV Coag 3 output spray SOW 42kV 2000 Ohm Bipolar output 525 kHz Cut output 90W 0 5 kV 100 Ohm 100 Ohm 1 Service manual Italian English 3 Short general surgery ball electrode 1 User manual Italian English Spanish 86 EULIA ELECTROSURGERY Slit A S Pype mtini aoe TA e RIEA ak Hospital HF Electrosurgical Units 250 and 400 Watt ARGON eo BE 7 CIMA Programme Memory m Gn ATERMO MB 400 ae Auto start stop bipolar in Plate flectronic C oe al Code 30694 DIATERMO MB 250 Code 30696 DIATERMO MB 400 DIATERMO MB250 and MB400 are high frequency electro surgical equipments suitable to deliver current for monopolar cut and coagulated cut with different levels of coagulation bipolar cut and coagulation During bipolar coagulation there is an automatic Autostart Autostop system activating when coagulation is reached A range of ten different modes and power levels can be easily stored and recalled It is possible to use either single plate neutral electrodes or split conductive zone electrodes in order to Technical specifications MB250 MB400 Work condition memorization Digital power visualization Continuous check control Automatic control of the plate patient connection Automatic control of the impedance Automatic control of excessive time for distribution Automatic co
3. Manual available in English Italian Spanish French Maximum output power BIPOLAR W 40 Crest Factor CUT V5 Crest Factor BLEND Dal Crest Factor COAG FORCED 2 0 Crest Factor COAG SOFT V7 Crest Factor BIPOLAR LS Working frequency 600 kHz Weight Kg 8 Size LxHxD mm 360x150x265 Operating voltage switchable 115 230 V 50 60 Hz Fuses 230Vac 5x20 TIMED 2x 3 15A Fuses 115Vac 5x20 TIMED 2x 6 3A Five steps adjustable sound level from 55 to 75 dBA Self check Power accuracy output warning Split or not split patient plate allowed Repetition of timed delivery Timed delivery Last working condition storing Electrical Class EN60601 1 MDD 93 42 EEC Class Patient circuit 83 ELECTROSURGERY Diatermo MB 122 and MB 160 mono bipolar 120W 160 W FOOT SWITCH o Mb l ope Te MODEL TAERE OUTPUT COA FRI Qt UT FRI gt PNE EO m Q 600 KHz de ie IP21 EW Ie e 16W 2002 600 KHz o a WARNING NO OPERATOR SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL A nt 10sec 25s FORCED SOFT BLEND COAG COAG BIPOLAR Code 30540 DIATERMO MB 122 mono bipolar 120 W Technical specifications Code 30541 DIATERMO MB 160 mono bipolar 160 W Minimum preselectable power Level step MB 122 and 160 are HF electrosurgical units suitable to Re Re a DOW e CUT CRD 56 eG effect middle monopolar or bipolar electrosurgery Maximum output power BLEND W 90 2002 By selection
4. 00 times Same as 30554 but with a screw clamp locking system that not only guarantees a safe contact but also adapts to the different electrode diameters Code 30551 KIRKY SINGLE USE HANDLE STERILE Single use handle with click push buttons for cut and coag Includes blade electrode minimum order 10 pcs Code 30553 GIMA SINGLE USE HANDLE STERILE POLO IES Same as 30551 minimum order 10 pcs PAE R DPE COE for all above handles These handles are provided with a 1 Pin socket 4 mm that fits all 106 HANDLES Gima Diatermo and majority of electrosurgical units in the market C These handles do not have push buttons Autoclavable handle without buttons provided with a 3 meters long cable and a blade electrode A lt 0086 It can be autoclaved up to 50 times Code 30518 KIRKY SINGLE USE 106 HANDLE STERILE 30518 single use Single use handle without button with blade electrode 22 1 pin 4mm with 4 mm PIN connection socket for above handles minimum order 10 pcs MICROSURGERY Microsurgery accessories for all GIMA Diatermo and electro depilators Code 30552 MICROSURGERY HANDLE Code 30560 MICROSURGERY NEEDLE ELECTRODE BRUSH Code 30537 ELECTRODE BRUSH 50x50 mm Disposable sterile radiopaque abrasive tip cleaner pad Box of 100 Monopolar Forceps Scissors and Cables Monopolar forceps are provided with a 4 mm NEL tip 2mm connection for standard monopolar cables FDA These can be use
5. 66 METAL PLATE without cable Code 30563 CABLE FOR PLATES 5 m Code 30559 CABLE FOR PLATES 2 5 m EUNA ELECTROSURGERY Monopolar Handles with or without switches CE MB HANDLES GIMA autoclavable electrosurgery pencils with CUT COAG aii switch have been studied and tested to offer maximum reliability and functionality to the operator MB handles are provided with a 3 Pins socket Valley Lab type that fits all Gima mono bipolar Diatermo MB 122 132 160 200 202 240 380 and majority of bipolar electrosurgical units Aspen Lab ES Generator EMC Statome Danieli Braun Berchtold Ohmeda Ritter Conmed Eschman Bovie Martin Kontron Bard Birtcher 771 Cobi Valley Lab Led Erbe z Code 30554 MB AUTOCLAVABLE HANDLE 100 times i Autoclavable handle with 2 large click push button provided with 30548 a 3 meters long silicone cable and a blade electrode It can be autoclaved autoclavable up to 30 times up to 100 times 20 times electrode For electrodes 2 4 mm Code 30548 STAR AUTOCLAVABLE HANDLE 30 times Same as code 30554 but autoclavable up to 30 times electrode C 0086 30551 single use 30553 C lt 0120 single use 30547 screw type autoclavable up to 100 times is autoclavable up to 20 times For electrodes 2 4 mm Code 30549 STAR 5 AUTOCLAVABLE HANDLE 30 times Same as STAR but with a 5 meters long silicone cable Code 30547 ORION AUTOCLAVABLE HANDLE 1
6. Code 30546 DIATERMO MB 202 200 Watt DIATERMO MB200 and MB202 are HF electrosurgical units suitable to effect middle monopolar or bipolar electrosurgery The available waveforms and peak voltage value as well as the accurate HF leakage current operation for polypectomy TURP intrauterine resections endometriosis excision etc The units allow the accurate preset of the output power with as low as 1 Watt resolution and to perform coagulation with high crest factor current to get an elevated thermal effect as well as with low voltage low crest factor current to get coagulation in absence of carbonization Ten different programs related to ten different operative conditions could be stored and easily recalled by the surgeon The use of either split or normal neutral plates are allowed A special electronic circuit Skin Plate Electronic Control continuously warns the plate to patient contact safety and unwanted short circuit in the connecting cable An over time warning OVT is provided to prevent excessive heating of the tissue around the surgical target due to too long current delivery time DIATERMO MB202 furthermore can be used with current delivery time equal to that of actuation of the output power switch as well as with preset current delivery time in the range from 1 ms up to 999 ms The output pulse can be automatically repeated 1 to 250 times The presetting of the current delivery time is propre for collecting of bioptic sampl
7. ELECTROSURGERY AARON CAUTERIES Interchangeable tips Replaceable batteries Reusable handles No sterilization necessary 30590 Tip not included GIMA Interchangeable tip cauteries code Minimum order 10 tips Cautery handle AA tip not included High temp loop tip sterile High temp 2 flex loop tip sterile Recommended for All tips DER ENT GYN ENT Change A Tip Cauteries with High Temperatures High temp 5 loop tip long size sterile GYNAECOLOGY High temp fine tip sterile DER CARDIO Code 30580 ELECTROCAUTERY 1200 C fine tip The Electrocautery is a sterile bipolar battery operated disposable device for the cauterization of small vessels the temperature of the tip is 1200 C With a fine tip required in most of the surgeries Made in Italy Code 30582 GYNAECOLOGY CAUTERY 1200 C fine tip Same as 30580 but with the tip fixed on a shaft 12 cm long Code 30581 ELECTROCAUTERY 600 C fine tip Same as above but with lower temperature 600 C Expecially designed for ophthalmology Code 30583 EMERGENCY ELECTROCAUTERY 800 C Thick tip Same as above but with thick tip that permits the perforation of nails in case of haematoma Weight 65 g Long life internal length 18 cm g lifi battery 60 min Histofreezer Cryotherapeutic aid for the treatment of warts Code 30585 HISTOFREEZER mini kit One 40 ml aerosol bottle 2 applicators 2 mm and 3 applicators 5
8. PHTHALMIC MICRO OPHTHALMIC MICRO their use with GIMA Diatermo and electrosurgery units from the main European manufacturers 30669 Mc PHERSON STRAIGHT OPHTHALMIC MICRO 30621 SEMKIN 30622 CUSHING 30623 JANSEN BAYONET IMA Z Length Straight ti Model Saas Application cian alag code Size ADSON m cm 4 m7 GENERAL PLASTIC SEMKIN GENERAL PLASTIC GENERAL PLASTIC GENERAL PLASTIC 1 mm round points 0 5 mm points 1 mm round points 1 mm round points 15 9 cm 6 1 4 UNIVERSAL US CONNECTOR Quality highly flexible silicone bipolar cables Autoclavable at 137 C 3 m long 10 Suitable for most generators see below compatibility and with connector for European or US forceps GIMA code Connector to forceps g 4 mm banana plug GIMA MB240 250 380 400 VALLEY LAB CONMED CODMAN OLYMPUS Connector to electrosurgical unit check beside compatibility list for brand and model BERTHOLD AESCULAP WOLF SIEMENS 90
9. PR 1 1 Class Class Group 2 B Duty Cycle action pause in seconds 10 30 Output power control by foot switch or finger switch Ten seconds delivery warning OVT Polycarbonate covered panels Conform to EN60601 1 1998 Conform to EN6060 1 1 2 2003 Conform to EN6060 1 2 2 2000 MONOPOLAR 2 control impedance stability of plate to patient contact during the surgical operation Control of the units is made by front panel keys and display mains inlet is located on the rear panel The units have automatic control systems to monitor the internal parameters and alert on possible damages errors The operational parameters used are constantly stored so that the last selected parameters are recalled every time the unit is switched on or the operative method is changed The level of sound can be adjusted every operator can choose his own level according to the environmental working conditions The units can work through handles with pushbuttons or handles without pushbuttons but with double foot switch It s possible to connect bipolar forceps to the unit for the bipolar functions Wide Dissipative Ventilation grille surface RS 232 interface ponete Unel Voltage selector Equipotential Connection plug for enslaved external unity Connection for enslaved Argon Plasma unity Standard Accessories 1 Power supply cord SIEM CEE 5 m 1 Two button handle autoclavable code 30547 5 Two butt
10. d with all Gima Led Erbe APPROVED and many other electrosurgical units in the 0120 Monopolar cable 4 mm pin Straight monopolar forceps 19 cm 7 7 Metzenbaum Bayonet monopolar forceps 19 cm 7 7 Monopolar scissors 18 cm 7 Metzenbaum monopolar scissors straight 18 cm 7 Metzenbaum monopolar scissors curved 18 cm 7 89 ELECTROSURGERY Universal High Quality Insulated Bipolar Forceps Ophthalmic Micro forceps 30667 E Si 30654 Bayonet forceps SEa General forceps Binner forceps for ENT application MC PHERSON 30669 e I 30646 JEWELER 30665 por Angled tip pe angel C Ce 0120 ISO 9001 l T P A l ISO 13485 JEWELER 30666 STRAIGHT STR with irrigation STRAIGHT STRAIGHT STRAIGHT STRAIGHT BAYONET BAYONET STRAIGHT STRAIGHT STRAIGHT JEWELER JEWELER STRAIGHT STRAIGHT STRAIGHT STRAIGHT ANGLED ANGLED 45 STRAIGHT STRAIGHT STRAIGHT STRAIGHT ANGLED ANGLED STRAIGHT STRAIGHT ANGLED STRAIGHT STRAIGHT STRAIGHT ANGLED STRAIGHT ANGLED 1 mm round points 1 mm round points 1 mm round points 2 mm round points 1 mm round points 1 mm round points 1 mm round points 1 mm round points 0 3 mm points 0 3 mm points rrigation EUROPEAN CONNECTION Our forceps are provided with a standard European connection enabling 0 25 mm points 0 25 mm points 0 5 mm points 0 5 mm points OPHTHALMIC MICRO OPHTHALMIC MICRO O
11. es and for microsurgical dermatologic operationy like treatment of telangiectasias spider nevus angiomas etc Bipolar cable and forceps are not included in standard accessories Technical specifications Minimum preselectable power 0 0 Level step digital 1 1 Maximum output power CUT W 200 250Q 200 2509 Maximum output power CUT 90 W 200 250Q 200 2509 Maximum output power CUT 80 W 200 250Q 200 250Q Maximum output power CUT 70 W 200 250Q 200 2509 Maximum output power BLEND W 120 200Q 120 2009 Maximum output power COAG FORCED W 150 150Q 150 1S0Q Maximum output power COAG SOFT W 90 1009 100 100Q Maximum output power BIPOLAR W 100 100Q Maximum output power BIPOLAR COAG W 100 1009 Maximum output power BIPOLAR CUT W 120 2509 Crest Factor CUT ES Crest Factor CUT 90 1 6 1 6 Crest Factor CUT 80 1 7 I7 Crest Factor CUT 70 1 8 1 8 Crest Factor BLEND 2 Crest Factor COAG FORCED 2 0 2 0 Crest Factor COAG SOFT E Crest Factor BIPOLAR Crest Factor BIPOLAR CUT W 15 Crest Factor BIPOLAR CUT W I5 Working frequency 600 kHz 600 kHz Weight Kg 8 8 Size LxHxD mm 360x150x265 360x150x265 Selectable mains power Vac 115 230 115 230 Mains frequency Hz 50 60 50 60 Fuses 230Vac 5x20 TIMED 2x3 15A 2x 3 15A Fuses 115Vac 5x20 TIMED 2x 6 3A 2x 6 3A Power accuracy output warning system 9 Split or not split patient plate allowed Timed delive
12. ility to damage those beneath is available for the operation OUTPUT CONTROL Bipolar power distribution l w CUT Output power levels are adjustable though incremental z h encoders that allow the exact pre sets and repetition of the eA COAG values The output function is linearized and controlled by 23 ultra modern electronic micro controllers which will interrupt 3 power if any alarm condition happens E res 50 100 200 300 400 500 800 1200 1600 2000 10 50 100 150 200 400 600 800 1000 LOAD OHA LOAD OHM Technical specifications DIATERMO MB 240 DIATERMO MB 380 Standard Accessories Activation devices Bipolar ooed 1 Power supply cord SIEM CEE 5 m Dual bipolar footswitch Working Max power Peak to peak Load 1 Two button handle autoclavable code 30547 monopolar manual frequency 240 MB 380 voltage resistance 5 Two button handle cold sterilizable Monopolar footswitch Monopolar output 475 kHz 1 Cable for disposable plate manual Cut output 250W 375W 14kV 300 Ohm 5 Disposable plate Mains 115 230 Vac 50 60 Hz Cut coag 1 output 225W 340W 1 4 kV 300 Ohm 1 Water proof double foot switch Absorption 800 VA Cut coag 2 output 200W 300W L4kV 300 Ohm 3 Short general surgery blade electrode Class I CF Coag 1 output 150W 225W 1 4 kV 300 Ohm Weight 15 kg Coag 2 output 100W 150W 1 4kV 300 Ohm 3 Long general surgery blade electrode Size 370x470x h150 mm 3 Short general surgery needle electrode Warranty
13. mm Code 30586 HISTOFREEZER mix kit One 150 ml aerosol bottle 25 applicators 2 mm and 25 applicators 5 mm Code 30587 HISTOFREEZER kit 2 mm One 150 ml aerosol bottle and 50 applicators 2 mm Code 30588 HISTOFREEZER kit 5 mm One 150 ml aerosol bottle and 40 applicators 5 mm Electrodepilator Code 28340 ELECTRO DEPILATOR 400 This device ensures a definitive depilation with thermolitic method It delivers a current of radiofrequency to cause the heating and consequent coagulation of the papilla reached through the introduction of a needle into the follicle of the hair Provided with highly reliable electronic integrated components with RF intensity adjustable with continuity and luminous working signal 82 Histofreezer tsch hulpmiddel It comes complete with footswitch handpiece for depilation depilation needle and power cable 2 m 30552 HANDPIECE FOR DEPILATION 30560 DEPILATION OR MICROSURGERY NEEDLES 30568 FOOTSWITCH CE EULIA ELECTROSURGERY pa ssi ca units 50W and 80W Arma Net hi CRs MED Footswitch operating Code 30516 DIATERMO 106 50W monopolar Code 30517 DIATERMO 108 80W monopolar These HF electrosurgery units are particularly suitable for small operations and are recommended for veterinary dentistry first aid and dermatology work They offer precision of cut and immediate coagulation and give excellent results in a large range of applications from uteri
14. ne coagulation to microcoagulation Programmable Emission Time Unit nee Code 30544 DIATERMO MB 132 mono bipolar 120 W Technical specifications 30516 106 Output power CUT 50W 400 ohm COAG 40W 400 ohm BLEND 45W 400 ohm MICRO 30517 MB 108 80W 400 ohm 50W 400 ohm 60W 400 ohm 20W 600 ohm Working frequency 600 KHz 10 700 KHz 10 Size 180x180xh100mm 180x 180 xh 100 mm Weight 2 8 kg 4 kg Operating Voltage 115 230 V 50 60 Hz switchable Electric input power 90 VA 230 VA Fuse 2x PAT 2x2A Alarm for overheating Footswitch operating Norms EN60601 1Class I CF EN 60601 1 2 93 42 EEC Class IIb Made in Italy Warranty 12 months Diatermo 106 and 108 standard accessories KIRKY single use handle without buttons Operative foot switch Flat neutral plate with cable 30563 Kit of 6 short autoclavable electrodes 2 4 mm length 5 cm Power cable 2 m Shuko plug User manual available in English Italian Spanish French in dermatology Moreover you can choose from a wide variety of electrodes for any need The modes of operation CUT COAG BLEND and MICRO 30517 only can be easily selected by a switch on the front panel The complete isolation between patient and the unit and strict respect of international norms guarantee total safe unplugged or not in contact with the patient or he cable is disconnected In this condition HF emission for cut and coagulation operation is switched
15. ntrol of the supplied power level Bipolar coag with automatic activation disact Consistent with Argon unit Minimum preselectable power 0 Unitary power step for powers from 0 W to 50 W Power step 10 for powers higher than 50 W Digital level display Selection of power through push buttons Size LxHxP mm 470x150x380 Weight kg 18 Selectable mains power Vac 115 230 Mains frequency Hz 50 60 Fuses 230Vac 5x20 TIMED 2xT 4A 5A Fuses 115Vac 5x20 TIMED 2xT 8A 10A Electrical input power VA 800 1000 Electrical input current 230Vac Self check Patient circuit F Defibrillation proof Equipotential binding Metallic cabinet Monopolar and Bipolar application Diatermo MB 250 and MB 400 Working Max Power Maximum Modulation Duty Crest Frequency MB250 400 output voltage factor Cycle Factor Monopolar Applications 425 kHz Cut Cut Coag 80 Cut Coag 60 Cut Coag 40 Enhanced Cut Blend Speedy Coag Deep Coag Spray Coag Spray Coag Argon Bipolar Applications Bipolar Cut Bipolar Cut Coag 80 Bipolar Cut Coag 60 Bipolar Cut Coag 40 Bipolar Blend Bipolar Deep Coag 300 Q 1500 Vpp Electrical input current 115Vac A 7 9 Five steps adjustable sound level Power accuracy output warning Skin Plate Electronic Control plate patient control Split or not split patient plate allowed Working condition storing last 10 setup Electrical Class EN60601 1 ICF MDD 93 42 EEC Class II b EN55011 CIS
16. of the modes of operation they provide pure cut Maximum output power COAG FORCED W 80 150Q coagulated cut forced coagulation soft coagulation and with Maximum output power COAG SOFT W 60 Ne f Boal lat Th Feith lj Maximum output power BIPOLAR W 40 1009 orceps Ipolar coagulation Ihe use of either sp it or normal Crest Factor CUT neutral plate is allowed MB 160 is recommended in case of Crest Factor BLEND operational fields damp for instance mucous or tissue whose Crest Factor COAG FORCED composition is varying with consequent need to have reserve ist Factor COAG SOFT p ying q Crest Factor BIPOLAR of usable power For these reasons MB 160 is suggested for Working frequency Gynecological and orthopedic surgery Weight Kg Leading Edge Technology This advanced concept device oe Sa See oad ese We Operating voltage switchable 115 230 115 230 enables highly professional surgery intervention thanks to Mains frequency Hz 50 60 50 60 ergonomic and safety features derived from high power Fuses 230Vac 5x20 TIMED 2x 3 15A 2x 3 15A theatre apparatus Fuses 115Vac 5x20 TIMED 2x 6 3A 2x 6 3A Ee Electrical input power VA 300 350 Complete safety Open Circuit OC Alarm warns the user Electrical input current stacey 13 15 that connection into the neutral plate has not been made or Electrical input current 115Vac A 2 6 that the cable is disconnected or the neutral plate is not in Five steps adjustable sound level from 55
17. off OVH Alarm the unit incorporates an internal circuit protection to warn when the current delivery lasts too long Technical specifications Minimum preselectable power 0 Level step 1 Maximum output power CUT W 120 Maximum output power BLEND W 90 Maximum output power COAG FORCED W 80 Maximum output power COAG SOFT W 60 HF electrosurgical unit suitable to perform middle monopolar or bipolar electrosurgery By selection of the modes of operation MB 132 provides pure cut coagulated cut forced coagulation soft coagulation and with forceps bipolar coagulation The use of either split or normal neutral plate are allowed Technology and precision Using the digital keyboard MB 132 enables the user to regulate the HF emission time in cut or coagulation mode with great precision and to reproduce a previous intervention Moreover it includes a useful repeat function which enables the user to repeat set impulses from 2 to 9 times and a timer to monitor the elapsed time of the treatment or the whole operation Complete safety an acoustic alarm intermittent beep and a blinking red led on front panel warns user that the neutral plate is Diatermo MB 132 mono bipolar standard accessories Two button handle autoclavable code 30547 MB operative foot switch usable in alternative to handle MB flat plate neutral electrode Kit 10 short standard electrodes diam 2 4 mm Power cable 2 m Microsurgery handle Microsurgery needle
18. on handle cold sterilizable 1 Cable for disposable plate 5 Disposable plate 2 HP double Water proof foot switch 3 Short general surgery blade electrode 7 cm 3 Long general surgery blade electrode 10 cm 3 Short general surgery needle electrode 5 5 cm 3 Short general surgery ball electrode 4 mm 6 cm 1 Electrode brush 1 User manual Italian English 1 Service manual Italian English 10 kHz 10 kHz 10 kHz 1 25 kHz 8 12 kHz 1 kHz 1 kHz WW We WR Re N N Re 7s ON Es ON Gn Gy GO GN we Standard accessories 87 ELECTROSURGERY Loop Colposcopy Autoclavable Electrodes 0120 C Electrode section 0 2 mm tungsten wire N 43 GIMA Reference Colposcopy electrodes 2 4mm Shaft Electrode Electrode code number autoclavable at 120 C length width depth Loop electrode 8 mm Loop electrode 15 mm Loop electrode 20 mm 11l cm 8 mm 8 mm 11 cm 15 mm 15 mm 11 cm 20 mm 15 mm minimum order 6 pcs Electrode wire straight Electrode wire angled 45 Electrode bend 4 straight Electrode bend 8 straight Electrode hook angled 45 Electrode wire 1 mm angled 45 Electrode straight slip knot straight Electrode angled slip knot straight Electrode ball point 3 mm angled 45 Electrode ball point 3 mm straight Set of 10 electrodes minimum order 10 pcs Needle electrode Blade electrode Ball electrode length 10 cm Ref GAINES Ra
19. ry repetition 1 999ms Electrical Class EN60601 1 I CF I CF MDD 93 42 EEC Class IIb IIb Patient circuit Duty cycle action pause in seconds Diatermo MB 200 MB 202 standard accessories MB two button handle autoclavable code 30547 handle in beside picture is not correct MB operative foot switch usable in alternative to handle MB flat neutral metal plate with cable Kit 9 short standard electrodes diam 2 4 mm Power cable 2 m Microsurgery handle Microsurgery needle 10 pcs only MB 202 Manual available in English Italian French only MB 202 85 ELECTROSURGERY Hospital HF Electrosurgical Units 240 and 380 Watt DIATERMO MB 240 5 J PEDAL MONO MANUAL r MONOPOLAR E BIPOLAR e OVH il A a a A Skin Plate EI i ectronic Control GINA CONTEMPORARY DUAL MODE MB 240 and 380 can A special electronic circuit Skin Plate Electronic Control continuosly 30690 be used in the same time in monopolar warns the plate to patient contact safety and unwanted short circuit in mode by handle and bipolar mode by footswitch the connecting cable Code 30690 DIATERMO MB 240 nos La PIA SAFETY OF USE Code 30692 DIATERMO MB 380 wr ea MeD Circuits dedicated to the safety of operator and patient are the These HF electrosurgical unit can be used to execute oes priority This ensure the leakage current is kept well under the monopolar and bipolar surgery in the many fields of values by the interna
20. sen Autoclavable electrodes 2 4 mm Cemaes dle code number number code 1 Single use electrodes 2 4 mm minimum order 24 pcs Sterile electrode Needle electrode sterile electrode Blade electrode sterile Ball 4 mm electrode sterile Sterile electrode Loop electrode 15mmx8mm Pediatric disposable plate 30562 disposable plate Code 30562 DISPOSABLE GROUND PADS WITH SOLID GEL adult Code 30567 DISPOSABLE GROUND PADS WITH SOLID GEL paediatric Code 30565 REM DISPOSABLE GROUND PADS WITH SOLID GEL adult Adult ground plate with solid gel Single use plate individually packed Code 30563 CABLE FOR PLATES 5m Universal cable to connect plates 30562 30565 30566 30567 to diatermo Safety lock with universal connection bipolar 6 3 mm plug 88 GIMA Reference Loop electrodes 2 4mm Shaft Electrode Electrode code number autoclavable at 120 C length width depth 50 13cm 10 mm 8mm 13 cm 15 mm 8mm 13 cm 20 mm 10 mm 15 16 17 17 cm Square loop electrode Loop electrode Loop electrode 3 4 5 T 8 ee 10 5 cm long electrodes reference number i ne AUTOCLAVABLE 10 cm long electrodes reference number 02 ee eS Oe ee eas i 30574 rem rubber plate 30566 metal plate i 30573 rubber plate 20x15 cm Code 30573 RUBBER PLATE 20x15 cm without cable Code 30574 REM RUBBER PLATE 20x15 cm without cable Code 30575 CABLE FOR RUBBER PLATES Code 305
21. tional requirements under every output application where high precision and reliability are essential condition Monopolar and bipolar output circuits are completely as in the endoscopic surgery floating and the use of the defibrillator is allowed while the EASY TO USE reference plate patient is connected Graphic icons allow an easy selection of the operation mode RELIABILITY l ee l All operating conditions and selected output controls are DIATERMO MB uses all solid state electronic circuits and is represented by bright digital indications made with interchangeable units for a fast and effective CUT maintenance Automatic control circuits protect the units from The monopolar cut can be performed by pure sine current to damage also in Cabe of repeated improper use obtain an incision with a minimum damage for the adjacent tissues and sure recovery for first intention Two different modalities of modulation allow to reduce bleeding during monopolar cut In the bipolar modality the cut can be effected by pure sine current HEMOSTASIS When the surgical action requires the obliteration of a blood vessel the availability of currents with different coagulative powers enables this type of work both with monopolar and bipolar surgery FULGURATION When it is necessary to cause a superficial necrosis of wide areas protecting the deeper tissues a special coagulant current that dehydrates the superficial layer of the tissue and reduces the possib