Home
SmarTemp Control fx 2.0
Contents
1. For a Spanish version of this document scan this QR Code SmarTemp Control fx Installation Operation Instructions Notes SmarTemp Control fx Installation Operation Instructions Notes Jebasto Feel the Drive Webasto Thermo amp Comfort N A Inc 15083 North Road Fenton MI 48430 USA Phone 810 593 6000 Fax 810 593 6001 Emall info us webasto com Internet http Amww webasto us http Amww techwebasto com Org 3 2015 Rev N A Ver 1 0
2. Jlebasto Feel the Drive SmarTemp Control fx 2 0 Digital Timer Interface Installation Operation Instructions General Thank you for choosing Webasto to meet your heating needs The Webasto SmarTemp Control fx 2 0 enables you to preset start up cycles of your Webasto heater 7 days a week with 4 individual times each day Operation The Webasto SmarTemp Control fx 2 0 is controlled using a rotary dial around the outside of the unit to scroll through menu options Simply click the selection button 0 to make your choice The following sections will define each menu item and its default setting Compatibility All Coolant Heaters the SmarTemp Control fx 2 0 has an output of 1A for the heaters ON OFF signal Heaters requiring a higher amperage signal will require a relay to accommodate different specifications See electrical connections for details Note Relay not included Mounting Procedure 1 Find a suitable mounting location on a flat surface if possible in a visible area CAUTION Always install in an area protected from the effects of weather and contamination 2 Use the drilling dimensions to lightly mark the two mounting holes Optional Step To route wire harness through the mounting surface drilla 17mm hole as notated on the drilling dimensions image NOTE Always make sure there are no obstacles behind the mounting location prior to drilling 4 Secure the Webasto SmarTemp Control fx 2 0 using the tw
3. port is not used for heater diagnostic purposes on SmarTemp Control fx 2 0 LCD Screen Legend Mode Auto or Manual Auto Mode Manual Mode TU Current Day TU lt Current Day TU lt Current Day Day and Time 8 15 Timer Active 8 15 lt Current Time 8 15 Current Time Auto gia ala Auto Mode gt iis 12 are HesterON Manual Mode usa Te Heater ON p gt 00 59 p gt 00 59 I NOTE When Auto is visible timers are enabled Runtime Remaining Runtime Remaining SmarTemp Control fx 2 0 Installation Operation Instructions Menu Descriptions Two modes are possible Manual Auto mode enables the pre defined timer programs Manual ON OFF functionality is still possible while in this mode Manual Mode allows the heater to be operated via the Webasto button on the SmarTemp Control fx 2 0 While in Manual Mode all Auto Mode functionality is permanently disabled Note While in manual mode the heater will continue to operate based on the pre defined Duration set by the user See Duration for further detail Language Language changes between English French and Spanish English Duration allows user to select the heater runtime of the heater Set range is between 60 minutes 10 120 minutes selectable by 10 minute increments Note Duration time for all timers will default to the set duration time User will have the ability to manually change duration for each timer Error Code This section will
4. the true runtime of the heater Itself Note For warranty purposes a diagnostic printout Is still required where applicable This hour meter is for reference only A password can be set to prevent access to the advanced Options menu Enter a 4 OFF digit code passcode to begin securing the Options menu Note This is typically used in fleet vehicle applications This displays the firmware version of the Webasto SmarTemp Control fx 2 0 Installed Version Select this to return to the previous screen N A IMPORTANT The Red status indicators heater ON and LCD screen backlight turn off after 30 seconds A touch of any button or a turn of the rotary knob will re activate these lights If the Webasto button is used to re activate these lights an additional press of this button is necessary to turn the heater off Note that when the heater is ON the display is active Installation Operation Instructions SmarTemp Control fx 2 0 Technical Information Rated Voltage 12 24V Operating Voltage Range 9V 32V Low Voltage Disconnect Range 12V 11 12 5V 24V 21 25 5V Operating Temperature 40 185 F 40 85 C NOTE Display visible to 22 F 30 C Installation Dimensions L x H x D 2 7 x 2 2 x 60 69 4mm x 55 5mm x 15 2mm 62mm 2 7 16 Use this drawing for dimensional reference only This is NOT a Template 8mm sad 5mm 3 16 D 17mm 11 16
5. log the last 5 error codes and the date that it was set Highlight and No Errors select an error code for a full description If the heater produces an error code the status indicator lights will flash red and the error will display on the main screen Error codes cannot be reset through the Webasto SmarTemp Control fx 2 0 on the heater a Webasto PC Diagnostics tool needed Refer to the heater service manual for resetting an error code Note Diagnostics via blink code is not available on all coolant heaters Error Codes on products with no blink code functionality can still be obtained using the PC Diagnostics test tool Refer to the applicable service manual by visiting www techwebasto com for detailed PC diagnostics information Advanced Level adjustment see below Timer amp Time amp Date allows user to properly set the current date and time User also has the AM PM Date ability to switch between AM PM and 24 hour format If the 24 hour format is mm dd yyyy selected the date format will change to dd mm yyyy Use the rotary knob to choose the time date and the selection button to confirm each entry The Webasto button can be used to go back to the previous field if additional changes are needed There are 4 heater start up cycles possible 7 days per week The timer is separated into to three categories The user can select Mon Fri set each specific timer T1 T4 for a typical work week all at once A weekend Sat Su
6. n can be scheduled in the same manner or a full week by using the Mon Sun selection The custom link allows the user to set a specific timer T1 T4 for each individual day Timer When selecting a specific timer a sub menu will appear Edit Skip and Off To change the timer cycle select edit Changes are saved immediately The skip feature allows a timer cycle to be skipped one time within a 7 day period Timer will reactivate after this one time skip cycle Note To turn a specific timer off permanently select off SmarTemp Control fx 2 0 Installation Operation Instructions Default SW Version LVD Low Voltage Disconnect allows the user to adjust the battery voltage level at which the Webasto SmarTemp Control fx 2 0 will shut the heater off A warning LED and message will appear after 8 minutes of low voltage The warning will remain on for 2 minutes before the heater Is shut off If battery voltage is equal to or less than the threshold selected 0 1v the heater will not start i e if an 11 5v threshold is selected the heater cannot be started until B has reached 11 7v 12 volt Range between 11v 12 5v 24 volt Range between 21v 25 5v al Default allows the user to perform a reset to all default values Note A power loss will not reset user programmed values The hour meter logs the operating hours of an active ON signal to the heater This does not reflect
7. o supplied 4 screws 5 Apply the supplied Heater Off warning sticker in a highly visible location to the driver s area Refer to the example sticker below WARNING 6 Observe the Menu Descriptions section for proper menu setup SmarTemp Control fx 2 0 Installation Operation Instructions Electrical Connections SmarTemp Connector Pin out Pin Number Description Wire Color __ ia Hav Red o DEN TERMINAL INSERT 4 biagnostic Blink Code TUT SIDE OF CONNECTOR For terminal removal use Molex terminal removal tool P N 11 03 0044 http Awww molex com Diagnostic Blink Code functionality does not apply to most coolant heaters Refer to the Error Code section for additional information Relay Connection If applicable Heaters requiring higher amperage ON OFF signal will require a relay to accommodate different specifications If the connected heater requires more than a 1A ON OFF signal to start use the pin out of a standard relay as described below Relay Pin 30 Battery B power source Fused according to required heater amperage Relay Pin 86 Heater ON OFF signal wire from pin 3 of SmarTemp Control fx harness Relay Pin 87 Switched ON OFF signal to heater Component Description Webasto ON Off Button Rotary Knob Screw Cap LCD Screen Status Indicator Light s Selection Button Micro USB Service Port The micro USB service
Download Pdf Manuals
Related Search
Related Contents
User manual Manuel d`utilisation 人口のうごき(平成 年 月 日現在) 人口 人( 人) 男 人( 人) 女 人( 人) 世帯 Mini-Max - User Manual - Honeywell Process Solutions クランプ電力計CW140 Owner`s Booklet du TREMPLIN . Copyright © All rights reserved.
Failed to retrieve file