SeccoProf EL Service Manual

image

Contents

1. OLIMPIA SPLENDID TECHNICAL FEATURES Secco Prof Power Supply 230V 50Hz Input Power 270C 65 U R 520 W 2 2A Max Input Power 32UC 80 U R 620 W 2 7A Dehumidification Capacity 2700C 65 U R liters 18 24 h 0 230 kg Air Flow 380 m 3 h C OPERATING WORKINGLIMITS O o Min working conditions in dehumidification mode DB WB OLIMPIA SPLENDID INTRODUCTION The dehumidifier is fitted with an electronic logic system which controls operation and optimises consumption and performance The keys and information on the control panel have the following meanings 1 Start Stand by key 2 Desired humidity temperature increment key 3 Desired humidity temperature decrement key 4 Humidity indication key 5 Detected ambient humidity blinking Selected humidity 6 Condensate collection tank full or tank shortage LED ON Continuous discharge function enabled LED BLINKING with frequency 1 25Hz Tank empty oresent with continuous discharge disabled LED OFF 7 Operating mode selection key 8 DRYING MODE indications LED ON 9 DEHUMIDIFICATION MODE indications LED ON SELECTING FUNCTIONS Stand by Key 1 This key activates the dehumidifier or puts it in Stand by mode Humidity set point The set point can be adjusted from 30 to 90 Rh in steps of 5 pressing the UP Key 2 or DOWN Key 3 keys increases or decreases the set point val
2. itch off only in the following cases cut in of the tank full switch operation in defrosting mode alarms the switching off of fan always delays for 30 seconds compared with compressor DEFROSTING MODE lf there is a frost condition evaporator temperature lt Ft and compressor ON the compressor remains on for a maximum time equal to Co minutes at the expiry of which air defrosting takes place fan on and compressor off which terminates when the pre set temperature is reached evaporator temperature gt St compatibly with the minimum compressor OFF duration of 5 minutes If the formation of frost is detected and the compressor is stopped due to reaching of the set point before the expiry of Co the fan remains on until the end of defrosting temperature is reached OPERATION WITH CONTINUOUS DISCHARGE To operate the dehumidifier with continuous discharge carry out the following operations e Take the tank out of the appliance e Connect the rubber pipe provided in the outfit to the condensate collection tank at the top of the tank compartment e Secure the pipe with the metal clamp provided e Simultaneously press the increment key 2 and decrement key 3 for three seconds with the machine in function The activation of this function is indicated by the flashing tank symbol 6 The continuous discharge function is cancelled if the empty tank is refitted OLIMPIA SPLENDID ALARM CODES Display Likely Cause Sugge
3. s present input closed Pressing the key 3 the software refresh the standard display as evaporator temperature Pressing the key 7 the software refresh the standard display as relative humidity value Press the stand by key or disconnect the power supply to quit the auto test mode OLIMPIA SPLENDID SECCO PROF WIRING DIAGRAM A1 Electronic card power A2 Electronic card control B1 Humidity feeler B2 Evaporator sensor F1 Compressor thermal cut out K1 Compressor relay K2 Fan control M1 Motor driven compressor M2 Fan S1 Tank presence micro switch S2 Tank full micro switch T1 Transformer X1 Power supply terminal board X2 6 pole connector X3 5 pole connector X4 2 pole connector
4. sted Solution Indication Hr flashing Relative humidity drops below very low values lt 22 Activate the dehumidifier with higher ambient humidity conditions Humidity sensor broken Change humidity sensor or model tE flashing The ambient evaporator temperature sensor Change ambient temperature is damaged sensor or whole PCB according to the model Lo flashing The ambient temperature is too low It means that after Activate the dehumidifier with 30 minutes of operation in defrosting mode compressor higher ambient humidity stopped and fan working the defrosting temperature conditions does not exceed St Alarm reset automatically after room temp rise up St Range scheduled Compressor in defrosting ON time Compressor minimum OFF time prt 90 90 A Frostaccumulation temperature o St ot 9 3 End of defrosting temperature AUTOTEST MODE By pressing the keys 3 7 for 3 seconds in sequence with the unit in Stand by the following sequence is started each phase has a duration of 3 seconds switch on of all symbols of the displays display of the software release activation of the fan and compressor displaying the code At The compressor remains ON continuously independently of the set point and the tank level switch the pause between stop and subsequent start and the defrosting function are also excluded The tank level symbol is active if the tank is absent switch open off if the tank i
5. ue by 5 Mode Key 7 Pressing this button the following operating modes can be set e DEHUMIDIFICATION indicated by the drop symbol led ON During first 5 seconds the display will show the detected humidity flashing numbers e DRYING indicated by the HI symbol light on the display and corresponding HI led ON this indicates that the dehumidifier is running continuously at maximum power OLIMPIA SPLENDID FUNCTION DETAILS e DEHUMIDIFICATION indicated by the drop symbol light on the control panel Compressor and fan are switched on if the minimum OFF time Cf has elapsed and if the relative humidity value is higher than the set point 3 compressor and fan remain ON as long as the relative humidity value is above the set point 3 when below the set point 3 compressor and fan switch off the fan switch off is delayed by 30 seconds with respect to the compressor and remain off for a minimum time equal to Cf measured as from switch off of the compressor at the end of which compressor and fan are switched back on again if the relative humidity value is greater than the set point 3 Compressor and fan switch off only in the following cases cut in of the tank full switch operation in defrosting mode alarms the switching off of fan always delays for 30 seconds compared with compressor e DRYING MODE Compressor and fan are switched on if the minimum OFF time Cf has elapsed Compressor and fan sw

Download Pdf Manuals

image

Related Search

Related Contents

Software User`s Manual ACDIVOCA mobile phone based  Philips Permanent filter CRP727  Air Navigation Pro Manuel de l`utilisateur  Piega SUB 1 MKII User's Manual  Manual do Agente Censitário de Informática- ACI  Sample Gas Cooler EGK 10  Freno hidráulico de pistón único Instalación y  Sencor SMW 6022 microwave  BD baignade.cdr  VisualVNC – Mode d`emploi pédagogique  