Contents
1. SECCOPROF 38 1 Data sheet Descrizione Capacta di deumiificazone 1 Volume deumidificabie minimax Potenza di iscaldamento Potenza assorbita in deumidificazione 1 Assorbimento nominale in deumidificazione 1 Potenza assorbita massima in deumidificazione 2 Assorbimento massimo in deumidificazione 2 Potenza assorbita massima in deumidificazione U L U Assorbimento massimo in deumidificazione U L U Potenza assorbita max in deumidific riscaldamento U L U Max power absorption in dehumidif heating mode U L U OLIMPIA SPLENDID Unit di misura Unit Valori Value E S m w w A w A Ww A Assorbimento max in deumidific riscaldamento U L U Max absorption in dehumidif heating mode U L U Grado di protezione Protection level Max pressione di esercizio lato bassa pressione Maximum operating pressure low pressure side Capacita tanica Tank capacity m h Max pressione di esercizio lato alta pressione Maximum operating pressure high pressure side Dimensioni imballo Larg x Alt x Prof Peso senza mbalo Peso con mbalo Portata aria max Air volume max Dimensioni prodotto Larg x Alt x Prof Dimensions W x H x D Gas refrigerante carica Refrigerant gas charge Tensione di alimentazione minima massima Marcature di conform Enti certificatori Certification Mark CONDIZIONI LIMITE DI FUNZIONAMENTO OPERATIONAL LIMITS Temperature di esercizio massi
2. 30 C blinking 30 90 blinking Room air Temperature and relative humidity measured OFF HI Dry working function OFF Hr blinking Humidity sensor room air NTC sensor malfunction OFF tE blinking Evaporator NTC sensor malfunction OFF LO blinking Low temperature alarm 9 C 50 C At Autotest mode evaporator temperature value Co 5 50 Setup mode compressor defrosting ON time Cf 3 15 Setup mode compressor minimum OFF time Ft 9 9 Setup mode frost accumulation temperature St 0 9 Setup mode end of defrosting temperature tC 20 40 Setup mode set point temperature in combined mode 3 Buzzer and backlight OLIMPIA SPLENDID Activation mode Corresponding information Single short pulse Keys pressed on control board confirmation Two short pulses System activation through SW1 Three short pulses Parameter EEprom writing confirmation Five short pulses Autotest and Set up modes activation Intermittent for 15 seconds Tank micro switch opening Probe malfunctions Evaporator exchanger low temperature malfunction seconds 4 1 STAND BY MODE display mode set point etc 4 Working modes description 4 2 AIR CLEANING MODE When selected by SW2 see par 2 the fan is switched on while is switched off only in the following cases the tank switch opens or any alarm occurs When this function is selected the symbol S6 is switched ON while dig
3. 5 7 Setup mode By pressing the keys SW5 SW3 for 3 seconds in stand by mode it shall be possible to enter the setup function 5 beeps confirm that the function has been enabled When the function is active on DL1 and DL2 it shall be shown the parameter mnemonic whereas on DL3 and DL4 the current parameter value By pressing SWS it shall be possible to select the next parameter by pressing SW5 SW3 or SW5 SW4 SW5 first it shall be possible to increase or decrease the value In this case when the SW5 key is released the current value is stored in the memory 3 beeps confirm that the new parameter value has been stored but all new parameters will be stored in the EEprom memory only when the setup function is stopped by pressing SWI In order to quit the setup mode press the SW1 key or disconnect the power supply The default values shown in the table below are programmed during the electronics test process Hange m Mnemonic Parameters set Description scheduled a ee o omm 6 ALARMS 6 1 PROBES ALARM Any failures in the probes are displayed by Hr or tE blinking for the humidity sensor probe ambient probe and evaporator probe respectively in the case of a failure in the probes all the loads are de activated except the fan whose switching off has to be delayed by 30 seconds and an intermittent acoustic signal is emitted which can be silenced by pressing any key with duration of 15 seconds OLIMPIA SPLENDID
4. DL4 is shown 2 in order to recognize the proper SW release during EOL check inspection hot gas valve output power board output ER is switched ON for 6 seconds and S3 blinks then is switched OFF both fan and compressor are switched ON the LCD shows the code At on digits DL3 and DL4 and evaporator probe temperature on digits DL1 and DL2 The compressor remains ON continuously regardless of the RH set point and tank microswitch condition the defrosting function is disabled and compressor can be powered even if Cf minutes have not elapsed from previous compressor shut down OLIMPIA SPLENDID The tank level symbol S4 is switched ON if the tank is absent full microswitch open and remains OFF if the tank is present board input closed By pressing the key SW5 the unit shows the measured room air temperature and relative humidity values like during normal operations Once the compressor has been switched ON by pressing the key SW3 the hot gas valve power board output ER is energized and the symbol S3 is shown in blinking mode on display in addition to other displayed symbols By pressing again the key SW3 the hot gas valve and symbol S3 are switched back OFF In autotest mode in case any probe alarm Hr or tE occurs the relevant alarm code blinks on the LCD display without any acoustic signal emission Press the stand by key SW1 or disconnect the power supply to quit the auto test mode
5. The humidity probe signals the failure even if it measures a room relative humidity percentage below 22 a condition in which the unit must be deactivated Operation is automatically restored as soon as the relative humidity rises back above 22 6 2 LOW TEMPERATURE ALARM If after 30 minutes of operation in defrosting mode hot gas valve output ON and fan OFF the evaporator temperature does not exceed St then the compressor and hot gas valve are stopped the display shows the alarm code LO blinking and an emission of an intermittent acoustic signal is enabled which can be silenced by pressing any key with duration of 15 seconds Reset of this alarm status occurs automatically as soon as the evaporator temperature rises above the value stored in parameter St other than when the unit is switched to Stby mode and after a power mains interruption OLIMPIA 7 WIRING DIAGRAM SPLENDID AI Electronic card power Humidity temperature sensor card Electronic card control Humidity temperature sensor Evaporator sensor Compressor thermal cutout Bypass valve coil RY101 Bypass valve coil relay RY102 Compressor relay RY104 Fan relay M1 Motor driven A2 A3 BI IR a compressor M2 Fan SI Tank full microswitch 2 Tray presence microswitch S301 Signal key for the humidity room temperature detected S302 Desired humidity decrease key S303 Desired humidity increase key S304 Switc
6. ameter values can be stored in eeprom see related paragraph as the relative humidity value is above the set point 3 when below the set point 3 compressor and OLIMPIA SPLENDID fan switch off the fan is switched off 30 seconds later than the compressor and remain off for a minimum time equal to Cf measured from the compressor shut down at the end of which the compressor and the fan are switched back on again if the relative humidity value is greater than the set point 3 The relative humidity RH set point can be adjusted from 30 to 90 in steps of 5 By pressing the UP SW3 or DOWN SW4 keys the set point value is increased or decreased by 5 In this mode the defrosting function can operate as described in par 5 4 4 4 DRYING MODE When selected by SW2 see par 2 compressor and fan are switched on in continuous mode if the minimum delay time Cf has elapsed Compressor and fan shall be switched off in the following cases only the tank switch opens any alarm occurs the fan shall be always switched off after 30 secs from compressor shut down When this function is activated the symbol S2 is shown S3 blinking mode when hot gas valve output is ON and on digits DL3 and DL4 the message HI appears see par 2 In this mode the defrosting function can operate as described in par 5 4 5 Other functions and modes 5 1 Tank switch If the tank switch remains open for more than 2 seconds continuo
7. h on stand by key S305 Operating mode selection key TI Transformer XI 2 pole connector Zi Compressor capacitor Modello con valvola by pass Model with by pass valve Mod le avec valve de d rivation Modell mit Bypass Ventil Modelo con v lvula by pass Modelo com v lvula de by pass Model met bypass klep Movr Ao ue BaAB a by pass
8. its DL DL2 and DL3 DL4 show the actual room temperature and Relative Humidity values acquired button SWS is disabled The fan speed is the only one available power board output FANI 4 3 DEHUMIDIFICATION MODE Selected by SW2 and signalled by S1 S3 blinking mode when hot gas valve output is ON Compressor and fan power board output FAN1 are switched on if the minimum OFF time Cf has elapsed and if the relative humidity value is higher than the set point 3 compressor and fan remain ON as long As soon as the tank switch opens the unit has to switch off all the active loads except the fan whose switching off has to be delayed by 30 seconds switch on of the corresponding symbol in fixed mode and enable an intermittent acoustic signal for 15 seconds press any key with the acoustic alarm active or re close the microswitch to silence the alarm The board confirms any command by a brief acoustic signal and switching on the LCD backlight for 10 This mode can be selected by pressing SW1 key on the control board and is signalled by on In this condition if the key is pressed again all the functions previously selected are restored operating When switching to stand by mode all board outputs are switched OFF but if compressor was active the fan only continues to run for 30 seconds further before stopping In STAND BY mode and only in this mode it is possible to enter the parameter programming mode where new par
9. me Maximum operating temperature Temperature di esercizio minime Minimum operating temperature CONDIZIONI DI PROVA TEST PARAMETERS Cavo di alimentazione N poli x sezione mmq Power cable N pole x section mmq n 310 x 650 x 435 380 x 720 x 510 Tipo Type kg R134A 0 330 V F Hz V s e o m U L U DB 35 C WB 31 C L L U DB 2 C WB 1 C OLIMPIA SPLENDID 2 Control panel keys and display DL1 DL2 6 TT i e DL3 DLA Room air temperature Relative E H cho view 9 o L lA S1 Dehumidification S2 Drying mode S3 Defrosting enabled S4 Full water tank No water tank If blinking with frequency of 1 25Hz continuous discharge function is enabled SW1 Turn on Stand by key SW2 Mode selection key SW3 Humidity temp increasing key SW4 Humidity temp decreasing key SWS Room humidity temp key show on DL1 and DL2 the Room air temperature measured and on DL3 and DL4 the measured Room air relative humidity both in blinking mode and with duration of 5 seconds DL1 DL2 DL3 DL4 _In normal working operations they display the Set Temperature and Set Relative Humidity values respectively according to the function selected both in blinking mode and with duration of 5 seconds Furthermore following information can be shown Digit DLI and DL2 Digit DL3 and DIA Corresponding information OFF 30 90 Relative humidity set value 9 C
10. nction operation all outputs shall be switched OFF immediately and defrost function shall be aborted When the tank switch is enabled to work and is opened during a defrost session during Co count with hot gas valve output OFF or during hot gas valve output ON periods the unit behaves as usual all outputs are switched OFF the fan is switched OFF with 30 seconds delay acoustic signal and S4 symbol are enabled but when this switch is closed the interrupted defrost session shall be completed without resetting the Co counter if evaporator temperature conditions for defrosting are still present In this case too the compressor can be switched ON only when Cf minutes have elapsed starting from previous compressor shut down 5 5 Inhibition of Tank Full switch The tank full switch is ignored this function is accessed only if the level switch is open tank full or absent by keeping the SW3 SW4 keys pressed for 3 seconds 5 beeps confirm that the function has been enabled When the function is enabled the tank switch is ignored and the S4 symbol blinking indicates that the function is active The function is automatically terminated when the level switch is closed 5 6 Autotest mode When the unit is in Stby mode by pressing the keys SW4 SWS5 for 3 seconds SW4 first the following sequence is started 5 beeps confirm that the function has been enabled all LCD symbols are switched ON for 3 seconds the SW release is shown for 3 seconds on
11. pre set temperature St is reached evaporator temperature gt St when the hot gas valve output is switched back OFF and fan switched back ON standard working condition is restored OLIMPIA SPLENDID According to the above description the parameters Co and Ft refer to defrosting start condition higher Co and lower Ft values means higher ice accumulation on evaporator heat exchanger before defrosting whereas the parameter St refers to defrosting exit condition lower St value means shorter function duration As the compressor keeps always ON during defrost operations the hot gas valve activation period can be shorter than Cf minutes If the frost condition evaporator temperature lt Ft compressor ON and hot gas valve output OFF lasts for less than Co minutes then no defrosting operations shall occur In dehumidification mode if frost condition is detected and RH set point is reached within Co minutes the unit shall switch off the compressor and the fan 30 seconds later as usual and the defrosting function currently running is not completed If RH set point is reached during the hot gas valve output activation the unit must complete the defrosting function currently running before switching off the compressor keeps working with compressor and hot gas valve output ON and fan OFF until the evaporator temperature reaches St then all outputs can be finally switched OFF If Stand by mode is selected during any defrost fu
12. usly the unit has to switch off all the active loads except the fan that has to be switched off 30 seconds later switch on the corresponding symbol S4 in fixed mode and enable an intermittent acoustic signal for 15 seconds by pressing any key with the acoustic alarm active or by re closing the micro switch the alarm shall be silenced but still signalled If the switch is then closed for more than 2 seconds continuously the water tank alarm resets and the unit restores the previous working operation the compressor can be switched on again when Cf minutes have elapsed from its previous shut down 5 2 Auto recovery function The ON OFF status the set point the operating mode including tank switch inhibition are saved in EEprom memory After a black out or a power mains failure the unit recovers all operations previously set without observing any compressor Cf OFF time 5 3 Compressor switching Compressor can be switched ON only when Cf minutes have elapsed starting from previous compressor shut down 5 4 Defrosting function When a frost condition evaporator temperature lt Ft compressor ON and hot gas valve output OFF continuously occurs for Co minutes then defrosting takes place the compressor keeps ON the hot gas valve output is switched ON power board output ER and fan is switched OFF When hot gas valve output is ON the symbol S3 is shown in blinking mode on display see par 2 Defrosting function terminates as soon as the
Download Pdf Manuals
Related Search
Related Contents
BLU Studio 5.0 II 4GB 4G White rete - REcursive Template Engine Digipass app mobile - Manuel d`utilisation Introduction Now - Sonnet Technologies Lexmark Optra C710 Service Manual Manitowoc Ice K000187 User's Manual Anleitung - JETI model sro Standard commercial Commerce Equitable Fairtrade ION Audio Tailgater Bluetooth Copyright © All rights reserved.