Install and Manage the JumpStart Server
Contents
1. Before YouBegin Unpack the JumpStart Server Connect the JumpStart Server to a Display Wall Connect Power an ann Turn the Server On Complete the MicroTiles Connection Wizard Change the Display Wall Settings Update the Java Software Update the ECU and MicroTiles Firmware Disable DHCP coi sx ame 0 ee et Rm A Input and Output Connections Output Signals 2 Port DVI I Input Module No DVIsignal Recognizing Hard Drive Failures Turn the Server Off Specifications ssisivsssv RE UR VERS Main Chassis Main Memory I O Interfaces an aon Ko a moe a eR RR JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 iac dno a e eb d 5 CHRISTIE Storage ni uni ex tenen ark Me ge eee Vl ae By EE Y QS de 20 Power Requirements 20 Peripheral Devices sua a ee ee 21 Graphics Output AMD FirePro W600 21 DVI Input CO2I SL iii varaan on kh JE BORCA RR EROR EUR 22 Embedded PCI Express Gigabit NIC Server Adapter 23 Safety ine ey dei blood o AE v o ae ho edi ad Rode adi 24 Electromagnetic Compatibility 24 Reliability and Serviceability 24 Quality u a0 Aa eb dhe a abate a
2. For the most current technical documentation Eastern Europe ph 36 0 1 47 48 100 Middle East ph 971 0 4 299 7575 Spain ph 34 91 633 9990 please visit www christiedigital com Singapore ph 65 6877 8737 Beijing ph 86 106561 0240 Shanghai ph 86 21 6278 7708 Japan ph 81 3 3599 7481 South Korea ph 82 2 702 1601 CHRISTIE
3. CHRISTIE Power Precautions A power cord is included with your JumpStart server Before operating the JumpStart server make sure that you are using a power cord socket and power plug rated for your location Use only an AC power cord recommended by Christie Do not attempt operation if the AC supply and cord are not within the specified voltage and power range Do not allow anything to rest on the power cords Locate the server where the cord cannot be damaged by persons walking on it or objects rolling over it Never operate the server if a power cable appears damaged Do not overload power outlets and extension cords as this can result in fire or shock hazards Ensure the equipment is properly connected to the supply circuit and follow equipment ratings to avoid overloading the circuits Reliable grounding of rack mounted equipment should be maintained Particular attention should be given to supply connections rather than direct connections to the branch circuit Failure to observe these warnings could result in death or serious injury Installation Considerations When installing the JumpStart server in a closed or multi unit rack assembly the ambient temperature cannot exceed 35 C 95 F The maximum ambient temperature limit applies to installations at elevations of 1525m 5000 feet or lower For installations above 1525m 5000 feet lower the temperature by 1 C 1 8 F for every additional 305m 1000 feet
4. of elevation To allow unrestricted airflow around the JumpStart server maintain a distance of 15 24cm 6 inches or greater between the server and walls or other obstructions When installing the JumpStart server in a rack avoid uneven mechanical loading to reduce the risk of personal injury or equipment damage JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHAISTIE Introduction JumpStart Server Symbols These symbols can appear on the JumpStart server Symbol Precaution Indicates the presence of hazardous energy A circuits or electrical shock hazards Indicates that the area contains no user or field amp serviceable parts and electrical shock hazards may be present When present near an RJ 45 receptacle 1 indicates a network interface connection component Contact with the hot surface may cause personal injury A Indicates the presence of a hot surface or hot Electrostatic Discharge Precautions Electrostatic discharge ESD can damage electronic NOTICE components such as the system board CPU and modules ESD damage can shorten a component s life expectancy or render it useless Follow these precautions to reduce the risk of ESD damage to components e Ground yourself to the server chassis and ground the chassis to a proper ground point when working with a static sensitive component or assembly e If possible work on a grounded surface like a mat Keep electrostatic sensitive
5. Manage the JumpStart Server CHAISTIE Before You Begin Before you start your installation Turn the display wall and master ECU on Select a location for the JumpStart server that has access to power and can be connected to the display wall Select a location for the server that has unrestricted airflow so that the maximum temperature of 35 C 95 F is not exceeded If mounting the server in a rack avoid uneven mechanical loading Optional rail kit required 128 100102 01 Make sure the MicroTiles installation includes 1 to 6 ECUs anda single master ECU Ensure that your network provides Internet access for the JumpStart server The MicroTiles Web interface requires Adobe Flash which is not pre installed on the server because of license restrictions Unpack the JumpStart Server Remove the accessories box from the JumpStart server box Pull the JumpStart server out of the box with the handles on the upper corners of the server Remove the keyboard and mouse from the accessories box Connect the JumpStart Server to a Display Wall The JumpStart server includes an AMD FirePro W600 display module and 6 Mini DisplayPort to DVI adapters With this configuration you can connect a maximum of 6 display devices to the JumpStart server DVI D connection requires Extended Display Identification Data EDID which is detected at startup 1 Turn the ECUs and display wall on JumpStart Server Operation Manual 020 10101
6. MicroTiles Connection Wizard displays a message and provides a link to the MicroTiles Web interface Click the link and then click Configuration gt Firmware Upgrade gt ECUs and MicroTiles For more information see the MicroTiles User Manual 020 100329 XX at www microtiles com Click Downloads gt User Manuals Disable DHCP To work with JumpStart the ECU must be networked with DHCP disabled If you enable DHCP the MicroTiles Connection Wizard displays a message and provides a link to the MicroTiles Web interface Click the link and then click Configuration gt Ethernet In the DHCP list select Disabled and then click Apply For more information see the MicroTiles User Manual 020 100329 XX at www microtiles com Click Downloads gt User Manuals JumpStart Server Operation Manual 15 020 101018 01 Rev 1 04 13 Install and Manage the JumpStart Server CHAISTIE Input and Output Connections You can use a DVI I connection to connect the JumpStart server to other devices such as a computer To use RGB HDMI or Component connections a VGA HDMI or Component to DVI I adapter is required The maximum resolution of a DVI I connection can be WUXGA resolution 1920 x 1200 x 24 bit digital or QXGA resolution 2048 x 1536 x 24 bit analog The DVI I capture frame rates are determined by the number of simultaneous captures and the resolution Output Signals The Mini DisplayPort connectors on the rear of JumpStart server a
7. components in their static safe packaging until you are ready to install Always avoid touching pins leads or circuitry JumpStart Server Operation Manual 3 020 101018 01 Rev 1 04 13 Introduction CHAISTIE Technical Support If you are unable to resolve your issue contact Christie support e North and South America 1 800 221 8025 or tech support christiedigital com e Europe Middle East and Africa 44 0 1189 778111 or techsupport emea christiedigital com e Asia Pacific tech asia christiedigital com Related Documents For information about using the JumpStart client software see the JumpStart User Manual 020 101155 xx For information about using JumpStart with Christie MicroTiles see the JumpStart Quick Start Guide 020 100918 xx 4 JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHAISTIE Install and Manage the JumpStart Server This section provides information and procedures for installing and connecting your JumpStart server to a display wall A display wall with one ECU and a single row of MicroTiles cannot contain more than 15 MicroTiles The EDID resolution of a single MicroTile subarray might be set so that the incoming signal is larger than the native resolution of the MicroTile 720x540 pixels This could result in cropped images and videos To make sure the entire incoming signal is displayed use the master ECU web interface to set the EDID values manually What s
8. the RGB signals will be ignored en separate or composite sync is input e Sync can be bi level e No signal means no signal should be applied to the input JumpStart Server Operation Manual 17 020 101018 01 Rev 1 04 13 Install and Manage the JumpStart Server CHAISTIE No DVI signal If you do not see output on any of the display devices it is possible there is a problem with the EDID Close all applications Select Start gt Shutdown Disconnect the JumpStart server from AC power Change the cables or re seat the connectors Reconnect the JumpStart server to AC power JN LIC M Er Turn the JumpStart server on and confirm the configuration is correct Recognizing Hard Drive Failures Occasionally a failed hard drive can resume operation after you restart the JumpStart server or after you remove and then reinstall the hard drive If you continue to use a failing hard drive you could lose data Replace all hard drives that show symptoms of failure When a hard drive begins to fail a PosT message with a list of failed hard drives appears when JumpStart server is restarted The POST message continues to appear whenever the JumpStart server is restarted and a functional hard drive is detected Turn the Server Off When you press the power standby button some power supply components and internal circuitry remain active until the JumpStart server is disconnected from AC power When you turn the JumpStart server of
9. 8 01 Rev 1 04 13 CHxISTIE Install and Manage the JumpStart Server 2 Identify the master ECU A flashing green LED light on the right side of the back panel identifies the master ECU 3 Connect the smaller end of each Mini DisplayPort to DVI adapter to the port on the back of the server Be careful not to insert the adapters into the connectors the wrong way Port Description 1 DVI 2 Mini DisplayPort 4 Connect the other end of each cable to a DVI extension cable not supplied 5 Connect the extension cable to a display device in any order 6 Connect the keyboard and mouse to the USB ports on rear of the JumpStart server If you are connecting the server directly to the master ECU Q with an Ethernet cable and you are not using a router make sure the IP addresses on the server and master ECU are configured on the same network To configure the IP address of the server consult with your network administrator JumpStart Server Operation Manual 9 020 101018 01 Rev 1 04 13 Install and Manage the JumpStart Server CHAISTIE 7 Connect one end of a CATS Ethernet cable not provided to the Ethernet port on the rear of the JumpStart server 8 Connect the other end of the CATS Ethernet cable to an Ethernet port on the master ECU Connect Power 1 Connect the power cord packaged separately to the AC inlet on the rear of the JumpStart server 2 Connect the three pronged end of the power cord to a ground
10. Christie JumpStart Server a Operation Manual 020 101018 01 CHRISTIE Christie JumpStart Server Operation Manual 020 101018 01 NOTICES COPYRIGHT AND TRADEMARKS 2013 Christie Digital Systems USA Inc All rights reserved All brand names and product names are trademarks registered trademarks or trade names of their respective holders REGULATORY The product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the product is operated in a commercial environment The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of the product in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense This Class A digital apparatus complies with Canadian ICES 3 A NMB 3 A Cet appareil num rique de la classe A est conforme la norme ICES 3 A NMB 3 A du Canada 9 7 ze YFTE AT SE AAMAS A 7 7 e 9 xtv a EE ASA OAS F ssp BRA AR Je AANA ARE AS Eo qug GENERAL Every effort has been made to ensure accuracy however in some cases changes in the products or availability could occur which may not be reflected in
11. H and V sync composite sync 1 0Vp p 2dB 0 79Vp p 1 26Vp p 0 7Vp p 2dB 0 56Vp p 0 88Vp p 2V 75 ohms Embedded PCI Express Gigabit NIC Server Adapter Network Interface Compatibility Data Transfer Method Connector Network Transfer Rate 10Base T Half Duplex 10Base T Full Duplex 100Base TX Half Duplex 100Base TX Full Duplex 1000BaseTX Half and Full Duplex Cable Support 10Base T 10 100 1000Base TX JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 10 100 1000 T IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3ab 1000Base T PCI Express four lanes x4 RJ 45 10Mb s 20Mb s 100Mb s 200Mb s 2000Mb s Cat 3 4 5 UTP up to 100m 328ft Cat 5 UTP up to 100m 328ft 23 Specifications CHAISTIE Safety e CAN CSA C22 2 No 60950 UL 60950 1 e EN IEC 60950 1 Electromagnetic Compatibility Emissions FCC CFR47 Part 15 Subpart B Class A Unintentional Radiators CAN ICES 3 A NMB 3 A CISPR 22 EN55022 Class A Information Technology Equipment Immunity CISPR 24 EN55024 EMC Requirements Information Technology Equipment Marking The controllers are designed to comply with the rules and regulations required for the product to be sold in various regional markets including USA Canada European Union Australia New Zealand Kuwait China Korea Japan Mexico Ukraine Russia South Africa and Saudi Arabia Reliability and Se
12. In the Box e JumpStart server e Accessory Box e Product registration card e Quick Setup Guide e JumpStart Software CD e JumpStart Operation Manual e Keyboard and mouse e Mini DisplayPort to DVI D dongle e DVI to VGA adapter 2 per CO21 SL module e DVI to Component adapters 2 per CO21 SL module e DVI to HDMI adapters 2 per CO21 SL module JumpStart Server Operation Manual 5 020 101018 01 Rev 1 04 13 Install and Manage the JumpStart Server CHAISTIE Front Panel Components 1 Optical drive 2 b Power button 3 Hard drive activity light 4 eMe USB 2 0 port black 5 SSL USB 3 0 2 blue 6 Q Headphone connector 7 Microphone connector IEEE 1394a FireWire connector co S IO JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHAISTIE Install and Manage the JumpStart Server Rear Panel Components 1 Power cord connector 8 Audio line out connector green es gt 2 PS 2 mouse connector 9 green 9 Microphone connector pink o e USB 2 0 ports 4 black 4 J 45 network connectors 11 24 jJ Ko IEEE 1394a FireWire connector USB 3 0 ports 2 blue orange Bottom connector z is AMT enabled 5 Audio line in connector 12 PS 2 keyboard connector blue ie purple 6 Graphics card connector 1 3 k b Rear Power button 7 Security slot 14 Power supply Built In Self Test BIST LED JumpStart Server Operation Manual 7 020 101018 01 Rev 1 04 13 Install and
13. MB Power Reguirements Standard 800 Watt Custom PSU Range Line Voltage 100 240V Rated Input Voltage 100 240V Rated Input Freguency 50 60Hz Rated Input Current 3A 20 JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHKXxISTIE Specifications Peripheral Devices Keyboard Type Interface Mouse Type Interface Generic PS 2 or USB 2 button optical with scroll wheel PS 2 or USB Graphics Output AMD FirePro W600 Card Format Form Factor Graphics Memory Number of Output Channels Max Digital Output Resolution per Channel Max Resolution Bandwidth Min Resolution Bandwidth Max Cards per System Connectors Max Power Consumption Supported Display Modes DisplayPort Protocol JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 PCI Express Gen3 x16 Full Height Half Length 2GB GDDR5 6 4096x2160 4K 30bpp O 60Hz DisplayPort 1 2 2560x1600 WQXGA Dual Link DVI 1920x1200 WUXGA Single Link DVI 165MHz 25MHz 1 6 display channels 6 mDP connectors compatible with all other outputs with adapters 75 Watts All available in 16bpp and 32bpp 1 2 21 Specifications DVI Input CO2I SL CHRISTIE This table lists the frame rate for non interlaced sources and the field rate for interlaced sources Signals are displayed at a lower rate frames are dropped The CO2I SL capture card might be able to display resolutions not listed in the table H
14. ch serial port is the master ECU connected to Serial Port COM1 Md Baud Rate 115200 x Default 115 200 bps 6 Click Test If an error message appears make sure that your master ECU and display wall are on and that your JumpStart server is connected properly 12 JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHAISTIE 7 Click Next Install and Manage the JumpStart Server 8 Select one of these options MicroTiles Connection Wizard 4 MicroTiles Connection Wizard Step 4 of 6 Automatically configure MicroTiles resolution server will restart Recommended JumpStart will automatically set the EDID values on each ECU in order to achieve the maximum total canvas resolution supported by the graphic cards installed on the server Manually configure MicroTiles resolution Use the MicroTiles WebUl to adjust the EDID values on each ECU as desired Click here to access the Webll For more information on customizing EDID values click for Help Option Automatically configure MicroTiles resolution server will restart Recommended Manually configure MicroTiles resolution 7 Click Next twice JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 Description The MicroTiles Connection Wizard sets the extended display identification data EDID values on each ECU to achieve the optimal canvas resolution supported by the server If you have subarrays defined
15. e Rhee ed a ed ee 24 Environment aca Ki ana ae dank bed ow a rn oe dy C OE WR 25 JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHAISTIE Introduction This manual provides information and procedures for operating servicing and repairing the JumpStart server Only Christie accredited service technicians are authorized to service and repair the JumpStart server JumpStart software is designed to work with Christie MicroTiles but it can also be used with Christie rear projection and flat panel solutions JumpStart software manages tiled displays with up to four video inputs You can display multiple media files Microsoft Windows applications and live video on a 5 10 megapixel digital canvas Safety Warnings and Guidelines To make sure you remain safe read and observe all warnings and precautions before you service the JumpStart server General Precautions To prevent physical injury or equipment damage it is A DANGER important that you read Specifications on page 19 in its entirety before performing any service procedure covered in this manual e Do not modify any circuit e Disconnect ALL power to the JumpStart server before servicing Failure to observe these warnings could result in death or serious injury To reduce the risk of injury from a hot component allow the AWARNING surface to cool before touching JumpStart Server Operation Manual 1 020 101018 01 Rev 1 04 13 Introduction
16. ed AC outlet The Input voltage must be capable of 100 240 VAC 9 7A Turn the Server On Press the power button on the front of the JumpStart server and wait until the Windows 7 operating system initialization completes If your JumpStart server is connected to Christie MicroTiles the MicroTiles Connection Wizard appears See Complete the MicroTiles Connection Wizard on page 11 10 JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHxISTIE Install and Manage the JumpStart Server Complete the MicroTiles Connection Wizard 1 If the MicroTiles Connection Wizard is not open right click the Christie MediaServer icon in the Windows task bar and select MicroTiles Setup Wizard If you cannot see the MicroTiles Connection Wizard disconnect one of outputs and connect it to a computer monitor Complete steps 2 to 8 and then disconnect the computer monitor and reconnect the connector to the JumpStart server 2 Click Next MicroTiles Connection Wizard g NicroTiles Connection Wizard Step 1 of 6 A MicroTiles display has been or will be connected to this computer Let s spend a few moments to setup JumpStart Note This wizard may reboot the server when complete T Disable wizard auto popup when MicroTiles detected If the display wall is already configured you are prompted to confirm that you want to clear the current configuration To continue click Yes 3 Select Ethernet or Serial Click N
17. ext If you selected Ethernet move to step 4 If you selected serial move to step 5 MicroTiles Connection Wizard pe MicroTiles Connection Wizard Step 2 of 6 Connect the JumpStart server and master ECU to the network via ethernet or connect the JumpStart server to the master ECU directly via serial port How is it connected Ethemet Tip How do locate the master ECU on the MicroTiles display If there are multiple ECUs only the master ECU will have a blinking green LED light C Serial JumpStart Server Operation Manual 11 020 101018 01 Rev 1 04 13 Install and Manage the JumpStart Server CHAISTIE 4 Complete these fields Field Description IP Address The IP address of the master ECU Port The master ECU port to which the JumpStart server is connected MicroTiles Connection Wizard K 4 MicroTiles Connection Wizard Step 3 of 6 Where is the master ECU on the network IP Address 192 168 232 192 Tip Hold down the button on the master ECU for 10 seconds to display the IP Address referred to on screen as Pair Remote Control Port 3002 default 3002 Test Note The test may take a minute or two 5 Complete these fields Field Description Serial Port The master ECU serial port to which the JumpStart server is connected Baud Rate The baud rate of the master ECU serial port MicroTiles Connection Wizard g MicroTiles Connection Wizard Step 3 of 6 Whi
18. f to perform maintenance disconnect the power cord from the AC power supply Failure to disconnect the power cord may increase the risk of personal injury electric shock or equipment damage 1 Close all applications 2 Select Start Shutdown 18 JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHAISTIE Specifications Main Chassis Drive Bays Expansion Slots Cooling Chipset Processor Operating System Application Software 3 x hot plug 3 5 SATA drive bays 2 x media drive bays 2x PCIe 3 0 x16 x16 mechanical 1x PCIe 3 0 x8 x8 mechanical 1x PCIe 2 0 x4 x8 mechanical 1x PCIe 2 0 x1 x4 mechanical 1x PCI 33MHz 1 x 92mm CPU fan 2 x rear exhaust fan 1 x front intake fan 1 x 60mm rear memory fan 1 x 40mm front memory fan Intel C602 Intel Xeon E5 1620 3 6GHz 10M Windows 7 Professional 64 bit JumpStart Display Wall Control Software Main Memory Type Standard Capacity Memory Protection DDR3 1600 RDIMM ECC 16GB 4 x 4GB Advanced ECC with online spare capabilities JumpStart Server Operation Manual 19 020 101018 01 Rev 1 04 13 Specifications CHAISTIE I O Interfaces Mouse 1 Keyboard 1 USB 2 0 Ports 5 1 front 5 rear 3 internal USB 3 0 Ports 4 2 front 2 rear IEEE 1394 Firewire 2 1 front 1 rear RJ 45 LAN 2 Storage Capacity 1 TB Interface Serial ATA Transfer Rate Synchronous Max 6GB s Rotational Speed 7200 RPM Cache Size 64
19. ld I choose OK Cancel 9 Click Open the AMD Control Panel if you are using multiple ECUs and want to show full screen applications or use the Christie Interactivity Kit across the entire canvas For more information see the Catalyst Pro Control Center online help k 4 MicroTiles Connection Wizard Step 6 of 6 In certain fullscreen applications it may be useful to enable Eyefinity Mode in the AMD Control Panel Open the AMD Control Panel Click here for Help 10 Click Next 11 Click Done Change the Display Wall Settings Right click the Christie MediaServer icon in the Windows task bar and select MicroTiles Setup Wizard 14 JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHAISTIE Install and Manage the JumpStart Server Update the Java Software Do not upgrade the Java software with the web server running 1 On the JumpStart server desktop right click Computer and then click Manage Double click Services and Applications in the left pane Double click Services in the right pane Right click Christie Web Server and then click Stop Click gt Start gt Control Panel gt Java 32 bit Click the Update tab Click Update Now Return to the Services list right click Christie Web Server and then click Start Update the ECU and MicroTiles Firmware To work with JumpStart your ECUs and MicroTiles need the latest version of firmware When you need to upgrade the firmware the
20. on b Damage caused by misuse improper power source accident fire flood lightning earthquake or other natural disaster c Damage caused by improper installation alignment or by product modification if by other than a Christie authorized repair service provider d Problems caused by combination of the equipment with non Christie equipment such as distribution systems cameras video tape recorders etc or use of the equipment with any non Christie interface device e Failure due to normal wear and tear f Warranty does not cover image retention PREVENTATIVE MAINTENANCE Preventative maintenance is an important part of the continued and proper operation of your product Please see the Service Manual for specific maintenance items as they relate to your product Failure to perform maintenance as required and in accordance with the maintenance schedule specified by Christie will void the warranty CHKISTIE Table of Contents Introduction Safety Warnings and Guidelines General Precautions Power Precautions Installation Considerations JumpStart Server Symbols Electrostatic Discharge Precautions Technical Support Related Documents Install and Manage the JumpStart Server What s In the Box Front Panel Components Rear Panel Components
21. owever the quality of the image cannot be assured Card Format Format Factor Video Capture Memory Number of Input Channels Max Cards per System Supported Input Resolutions Digital Supported Input Resolutions Analog Supported Input Resolutions HD HDCP Input Connector Type Power Consumption Power Requirements Horizontal frequency range Vertical frequency rangel Scan format Dot pixel clock rate Active pixels per scan line Active lines per field non interlaced frame 22 2 5GHz PCIe 1 0 x4 adapter Full Height Half Length 64MB triple buffered 2 DVI I connectors 2 4 channels 640x480 VGA 800x600 1024x768 1280x1024 1600x1200 1920x1080 1920x1200 WUXGA 640x480 VGA 800x600 1024x768 1280x1024 1600x1200 1920x1080 2048x1536 QXGA 480p 576p 720p 1080p Not supported DVI I or HD15 VGA HDMI Component with adapter 15 Watts Max 3 3V O 0 25A 12V 2A 15 110kHz 25 200Hz Progressive Analog 25 170MHz Digital 25 165MHz 640 min 2048 max analog 1920 max digital 480 min 1536 max analog 1200 max digital JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHRISTIE Sync types Polarity Input levels sync Input offset Nominal impedance R G B with sync R G B without Specifications Separate H and V Composite bi level Sync on green bi level DVI Single Link Positive or Negative separate
22. re capable of displaying WUXGA resolution 1920 x 1200 at 60 Hz For SXGA resolution the refresh rates are 60 75 Hz Mini DisplayPort to DVI D adapters are included with the JumpStart server Connect display devices or ECUs to the 6 Mini DisplayPorts on the output module Module 1 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 16 JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHAISTIE Install and Manage the JumpStart Server 2 Port DVI I Input Module Each DVI I input module has two DVI I connectors A source connected to the top connector is considered Input 1 Module 1 Module 2 wc It hi Input 1 ur Input 3 Input 2 k Input 4 The DVI I input module can accept these input signals DVI D DVI A DVI I RGB VGA HD15 to DVI I adapter RGB 3 4 5 wire proper adapter HDMI HDMI to DVI I adapter and Component Component to DVI I adapter This table lists the specifications for the standard input VGA connectors Signal RED GREEN BLUE Hor Vert Description Comp RGB with H amp V Red Green Blue H Sync V Sync Sync 5 wire 1 2 3 RGB with composite Red Green Blue Comp No sync 4 wire 1 2 Sync signal 3 4 5 RGB with sync on Red Green Blue No No green 3 wire 4 5 with sync signal signal e Syncsignals cannot be swapped between the Horizontal Composite and Vertical connectors e Sync signal s can be negative or positive polarity e Sync present on any of
23. rviceability Reliability MTBF of major 50 000 hours components Serviceability MTTR 15 minutes max Quality e Manufactured at the Christie Canadian facility certified for ISO 9001 2000 and ISO 14001 2004 24 JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 CHRISTIE Environment Operating Temperature Relative Humidity Altitude Shock Single event only Vibration random non continu ous Non Storage Operating Shipping JumpStart Server Operation Manual 020 101018 01 Rev 1 04 13 Specifications 5 C to 35 C 40 F to 95 F NOTE Derate by 1 degree C 1 8 degrees F for every 305m 1 000ft altitude over 1 525m 5 000ft 8 to 85 non condensing 0 to 3 048m 10 000ft max Half sine 40g 2 3ms 0 5g rms 5 300Hz Temperature 40 C to 60 C 40 F to 140 F NOTE Derate by 1 degree C 1 8 degrees F for every 305m 1 000ft altitude over 1 525m 5 000ft Relative Humidity 8 to 90 non condensing Shock Single event Half sine 160cm s 2 only 3ms 100g Square 422cm s 20g Altitude O to 9 144m 30 000 ft max Vibration random 2 0g rms 10 to 500Hz non continuous 25 xO000 102906 MO 2 x ASSY TECH DOCS JumpStart Srvr Corporate offices USA Cypress ph 714 236 8610 Canada Kitchener ph 519 744 8005 Worldwide offices United Kingdom ph 44 118 977 8000 France ph 433 0 1 41 210036 Germany ph 49 2161 664540
24. they are reset If automatic configuration fails a link to access the MicroTiles Web interface appears so that you can complete the configuration manually 1 Click Click here to access to the WebUI 2 Click Canvas Management gt Layout gt Subarray Configuration 3 Click Auto Subarray 4 Click Source Management gt Customize EDID 5 Adjust the Horizontal Size Vertical Size and Frame Rate to match your display wall When you adjust these settings the Bandwidth required to achieve them is dynamically updated We recommend that the bandwidth should not exceed 150 MHz When you are finished 6 Click Apply For more information see the MicroTiles User Manual 020 100329 XX 13 Install and Manage the JumpStart Server CHAISTIE 8 Adjust the Microsoft Windows desktop display settings When your adjustment is complete click OK To detect your current setup click Detect To show the numbers corresponding to your displays on your display wall click Identify Screen Resolution lol xj CH Mi Control Panel tems v Display v Screen Resolution Search Control Panel 2 Change the appearance of your displays a Ga u Display 1 DELL 2007FP z Resolution 1600 x 1200 recommended Orientation landscape Multiple displays Extend desktop to this display This is currently your main display Advanced settings Make text and other items larger or smaller What display settings shou
25. this document Christie reserves the right to make changes to specifications at any time without notice Performance specifications are typical but may vary depending on conditions beyond Christie s control such as maintenance of the product in proper working conditions Performance specifications are based on information available at the time of printing Christie makes no warranty of any kind with regard to this material including but not limited to implied warranties of fitness for a particular purpose Christie will not be liable for errors contained herein or for incidental or consequential damages in connection with the performance or use of this material recycled and reused This symbol means that electrical and electronic equipment at their end of life should be disposed of separately from regular waste Please dispose of the product appropriately and according to local regulations In the European Union there are separate collection systems for used electrical and electronic products Please help us to conserve the environment we live in K The product is designed and manufactured with high quality materials and components that can be GENERAL WARRANTY STATEMENTS For complete information about Christie s limited warranty please contact your Christie dealer In addition to the other limitations that may be specified in Christie s limited warranty the warranty does not cover a Damage occurring during shipment in either directi