Home
B.A.S.I.S. Exit Hardware Trim Motor Assembly Replacement Kit
Contents
1. Manual Note Ifthe lock has a proximity card reader it may have already been activated by the presence of an object near the card reader 2 Use the temporary operator card to access the lock The green light flashes and the locking mechanism unlocks 3 Turn the lever and open the door Indianapo BEST ACCESS SYSTEMS If the mechanism doesn t unlock refer to the following table For additional troubleshooting instructions see the B A S I S G Service Manual or the B A S 1 S V Service Manual LEDs Sounder You should Single Use the card at a moderate speed red flash Red 3 short Use the temporary operator card flashes tones provided with the lock Green Check the motor connection flashes Check the battery connection For locks with key override Insert and turn the key to unlatch the door For locks with deadbolt 4 From the inside of the door turn the turn knob and make sure that the deadbolt operates properly 2001 2002 Best Lock Corp dba Best Access Systems is Indiana T61865 Rev 1881394 ER 7991 12 Oct 2002
2. ing plate A Mounting standoffs Escutcheon gasket Screw T Lift finger 2 Mounting standoffs Figure1 Removing and reinstalling the mounting standoffs gasket and lift finger Primary harness Cable tie N N Mounting plate screws 0 2 Slot _ 9 N L Mounting plate O 0 Mounting plate screws Figure2 Removing and reinstalling the mounting plate BEST ACCESS SYSTEMS Indianapolis Indiana B A S 1 S Exit Hardware Trim Motor Assembly Replacement Kit Instructions a Cut the cable tie and discard b Remove the five screws and discard c Carefully remove the mounting plate 5 Remove the lever return springs from the yoke See Figure 3 C Remove the motor assembly Lever return 1 Disconnect the motor connector from the primary springs harness See Figure 4 2 Using a screwdriver pry the sounder off the LZ escutcheon Ns 3 Using a 3 32 hex driver remove the socket head on Yoke sai and spacer Remove the motor assembly from the escutcheon D Reinstall the motor assembly 1 Rotate the gear on the motor assembly until the locking lever is as close to the screw hole as possible See Figure 5 Note f the locking lever does not move freely as you turn the gear gently move the locking lever into position Figure3 Removing and reinstalling lever return springs 2 Position the motor assembly in the escutcheon as shown in Figure 4 and
3. ket into position on the escutcheon Press the gasket into place 5 Screw the six mounting standoffs onto the mounting plate Figure 1 F Reinstall the escutcheon on door For instructions see the B A S I S G Service Manual or the B A S LS V Service Manual A Gear lever Socket head screw hole Figure5 Rotating the motor assembly gear S Se eee Motor harness Motor assembly Locking lever Figure6 Rerouting the motor harness BEST ACCESS SYSTEMS 3 Indianapolis Indiana B A S 1 S Exit Hardware Trim Motor Assembly Replacement Kit Instructions G Test lock for proper operation To test the lock for proper operation before the lock is programmed use the temporary operator card that came with the lock This card is for temporary use only After permanent cards have been programmed for the lock the temporary card should be deleted 1 Use the temporary operator card to activate the lock When the lock detects the presence of a card for the first time the lock performs a series of diagnostic self tests If no problem is detected the lock responds with 4 red LED flashes simultaneous with 4 green LED flashes and 4 short tones If a problem is detected the lock s red LED and green LED simultaneously flash in a repeating pattern and no tones sound The lock s control electronics board must be replaced For instructions see the B A S 1 S G Service Manual or the B A S 1 S V Service
4. make sure that m the locking lever is inserted through the locking plate m the motor assembly pivot pin is sealed in the recess in the escutcheon 3 Place the spacer on the socket head screw Using a 3 32 hex driver reinstall the socket head screw Motor 4 Route the motor harness into the groove in the connector escutcheon See Figure 6 Sounder 5 Reinstall the sounder onto the escutcheon See Figure 4 6 Connect the motor harness to the primary harness Motor assembly Socket head screw Figure4 Removing and reinstalling the motor assembly 2 BEST ACCESS SYSTEMS Indianapolis Indiana B A S 1 S Exit Hardware Trim Motor Assembly Replacement Kit Instructions E Reinstall components 1 With posts on the mounting plate inserted in the lever return springs slide the mounting plate into the escutcheon Figure 3 Make sure that the locking plate fits into the slot in the mounting plate Secure with the five new screws Route the primary harness against the mounting plate post and secure the harness to the post with a cable tie See Figure 2 2 Position the lift finger on the escutcheon in the orientation noted in step 3a on page 1 3 Position the washer on the lift finger screw Tightly secure the lift finger with the lift finger screw 25 30 foot pounds of torque Figure 1 4 Starting at the bottom of the gasket peel away the protective backing a small amount at a time while unrolling the gas
5. pr a pana a H wy ACCESS SYSTEMS Overview These instructions describe how to replace the motor assembly in your B A S 1 S Exit Hardware Trim EXG or EXBV Components checklist In addition to these instructions this kit part number 1878973 contains Q 1 Tape for mounting the sounder Q 1 Motor assembly Q 1 Socket head screw Q 1 Spacer Q 5 mounting plate screws Q 1 Lift finger screw Q 1 Escutcheon gasket Tasks to perform A Remove the escutcheon from door For instructions see the B A S I S G Service Manual T63300 or the B A S I S V Service Manual T61805 B Remove old escutcheon gasket mounting plate lift finger lever return springs and electronics board Caution Before you handle the electronics board or any component connected to it make sure that you are properly grounded using an electrostatic discharge ESD protection kit Touching the board without proper grounding can damage sensitive electronics components even if you don t notice any static discharge 1 Unscrew the six mounting plate standoffs from the mounting plate Figure 1 2 Remove the gasket from the escutcheon and discard the gasket 3 Remove the lift finger a Note the orientation of the lift finger b Remove the lift finger screw and discard c Remove the washer and lift finger 4 Remove the mounting plate Figure 2 B A S I S Exit Hardware Trim Motor Assembly Replacement Kit Instructions _ Lb Mount
Download Pdf Manuals
Related Search
Related Contents
SCOTT RX 12 J-120 Technical Manual - Garland View Manual - ActiveXperts.com BIRDY 250 LED Manuel d`utilisation Puppy Jump Manual PEP-VIEW für BBK 2013 - Hochschule für nachhaltige Entwicklung RIDGID R82002 12 VOLT DRILL REPAIR SHEET RIDGID R82002 GE Astat Plus Soft start Manual Copyright © All rights reserved.