Contents

1. of nails in case of haematoma length 18 cm 163
2. e 30540 DIATERMO MB 122 mono bipolar 120 W e 30541 DIATERMO MB 160 mono bipolar 160 W MB 122 and 160 are HF electrosurgical units suitable to perform middle monopolar or bipolar electrosurgery By selection of the modes of operation they provide pure cut coagulated cut forced coagulation soft coagulation and with forceps bipolar coagulation The use of either split or normal neutral plate is allowed MB 160 is recommended in case of damp operational fields for instance mucous with consequent need to have reserve of usable power For these reasons MB 160 is suggested for Gynecological and orthopedic surgery Leading Edge Technology This advanced concept device enables highly professional surgery intervention thanks to ergonomic and safety features derived from high power theatre apparatus Complete safety Open Circuit OC Alarm warns the user that connection into the neutral plate has not been made or that the cable is disconnected or the neutral plate is not in contact with the patient The alarm is signalled by an intermittent beep together with a flashing red light on the front panel In this case HF emission for cut and coagulation operation is switched off OVT Alarm The unit includes an internal circuit protection warning when the current delivery lasts too much Diatermo MB 122 MB 160 standard accessories MB single use two button handles MB operative foot switch 30577 usable as alternative to handle MB flat neutr
3. 1 200 C 2 200 F made in Italy interchangeable tips with nickel chrome wire SEJM e33 iS LB a i y i 5 ka a F replaceable batteries J A reusable handles 1 Wide application in gynaecology orthopedy ear nose throat dermatology plastic and reconstruction surgery ZNA 30599 o INTERCHANGEABLE TIP CAUTERIES m Eeka MINIMUM ORDER 10 TIPS 30598 Cautery handle AA tip not included 30601 cee 30600 gt 30599 High temp long fine tip sterile box of 10 C dous e 30600 High temp large tip sterile box of 10 30601 High temp fine tip sterile box of 10 E HIGH TEMPERATURE ELECTROCAUTERIES e 30580 ELECTROCAUTERY 1 200 C fine tip made in Italy Electrocautery is a sterile bipolar battery operated disposable device for the C 0086 cauterization of small vessels the temperature of the tip is 1 200 C With a fine tip required in most of the surgeries e 30582 GYNAECOLOGY CAUTERY 1 200 C fine tip Same as 30580 but with the tip fixed on a 12 cm long shaft 7 en es i wh e 30581 ELECTROCAUTERY 600 C fine tip seinen 5 PAOS i 30580 30581 ff 30582 THICK TIP FINE TIP Same as 30580 but with lower temperature 600 C 30582 PROT Expecially designed for ophthalmology al alata ig gt ony e 30583 EMERGENCY ELECTROCAUTERY 800 C Thick tip po Meo ss Same as 30580 but with thick tip for the perforation 30580 Weight 65g
4. 100 times Same as 30554 but with a screw clamp locking system ensuring a safe contact and adapting to different electrode diameters High insulation to prevent liquid damage For electrodes 2 4 mm e 30551 KIRKY SINGLE USE HANDLE STERILE Single use handle with click push buttons for cut and coag Includes blade electrode minimum order 10 pcs e 30553 GIMA SINGLE USE HANDLE STERILE Same as 30551 minimum order 10 pcs 1 pin plug HANDLES for diatermo 50 80 106 108 These handles are provided with a 1 Pin socket 4 mm fitting all Gima Diatermo and most of electrosurgical units in the market These handles do not have push buttons e 30519 AUTOCLAVABLE 50 80 106 108 HANDLE Autoclavable handle without buttons provided with a 3 meter long cable and a blade electrode It can be autoclaved up to 50 times e 30518 KIRKY SINGLE USE 50 80 106 108 HANDLE STERILE Single use handle without button with blade electrode with 4 mm PIN connection minimum order 10 pcs MICROSURGERY Microsurgery accessories for all GIMA Diatermo and electro depilators e 30552 MICROSURGERY HANDLE e 30560 MICROSURGERY NEEDLE e 30537 ELECTRODE BRUSH 50x50 mm Disposable sterile radiopaque abrasive tip cleaner pad Box of 100 MB HANDLES autoclavable up to 100 times 30550 autoclavable up to 60 times type connector for all above handles C 106 HANDLES 0519 autoclavable 30
5. 30635 DIATERMO MB 400D DIATERMO MB300 and MB400 are high frequency electro surgical equipments suitable to deliver current for monopolar cut and coagulated cut with different levels of coagulation bipolar cut and coagulation TWIN OPERATIVE ACTIVITY two output channels for monopolar cutting two independent setting and output channels for the most frequent monopolar coagulation CONTROLLED CUTTING PROCEDURES enhanced cutting current for eschar free incision cutting current with selectable coagulating property for bleeding controlled dissection low capacitive coupling by slow BLEND current for endoscopic procedures TWIN CONTROLLED COAGULATION PROCEDURES SPEEDY coagulation and DEEP coagulation available to two operators SPRAY coagulation by hand switch or foot switch controls EXTENSIVE BIPOLAR FEATURES bipolar cutting current with selectable bleeding control Slow BLEND cutting current TECHNICAL SPECIFICATIONS MB300 MB400 MB 300 Maximum out power monopolar pure CUT 300 W 300 0 Maximum out power monopolar cut coag CUT80 250 W 3000 Maximum out power monopolar cut coag CUT60 200 W 3000 Maximum out power monopolar cut coag CUT40 150 W 3000 Maximum out power monopolar cut ENHANCED 200 W 500 0 Maximum out power monopolar cut coag BLEND 200 W 300 0 Maximum out power monopolar coag SPEEDY 100 W 500 Q Maximum out power monopolar coag DEEP 100 W 200 0 Maximum out power monopolar coag SPRAY 70
6. DISPOSABLE NON WOVEN GROUND PADS adult ped 30559 CABLE FOR PLATES 2 5 m 159 E MONOPOLAR HANDLES FOR ELECTRODES WITH 2 4 mm GIMA autoclavable electrosurgery pencils with CUT COAG switch have been studied and tested to offer maximum reliability and functionality to the operator MB handles are provided with a 3 Pin plug Valleylab type fitting all Gima mono bipolar Diatermo MB 120 122 132 160 200 202 240 250 380 400 and most of bipolar electrosurgical units Asoen Lab ES Generator EMC Statome Danieli Braun Berchtold Ohmeda Ritter Conmed Eschmann Bovie Martin Kontron Bard Birtcher 771 Cobi Valleylab Led Erbe e 30554 MB AUTOCLAVABLE HANDLE 100 times Autoclavable handle with 2 large click push buttons provided with a 3 meter long silicone cable and a blade electrode It can be autoclaved up to 100 times electrode 20 times For electrodes 2 4 mm e 30545 MB AUTOCLAVABLE HANDLE 100 times Same as code 30554 but with a 5 m long silicone cable e 30550 PRIMA MB AUTOCLAVABLE HANDLE 60 times Autoclavable handle with 2 large click push button provided with a 3 meter long silicone cable and a blade electrode It can be autoclaved up to 60 times For electrodes 2 4 mm e 30548 STAR AUTOCLAVABLE HANDLE 30 times Same as code 30554 but autoclavable up to 30 times electrode is autoclavable up to 20 times For electrodes 2 4 mm e 30539 ORION PLUS AUTOCLAVABLE HANDLE
7. W 2000 Q Maximum out power monopolar coag SPRAY ARGON 70 W 2000 Q Maximum out power bipolar CUT 95 W 1500 Maximum out power bipolar cut coag CUT80 95 W 1500 Maximum out power bipolar cut coag CUT60 95 W 1500 QMaximum out power bipolar cut coag CUT40 60 W 150 Q Maximum out power bipolar cut coag BLEND 90 W 1500 Maximum out power bipolar cut coag BLEND 70 W 100 0 Working frequency monopolar bipolar Patient circuit 425 kHz 525 kHz F Selectable input voltage 115 230 Vac Mains frequency 50 60 Hz Electrical input voltage 1000 VA Size WxHxD mm 470x150x400 Weight 17 5 Kgs Controls Patient Plate circuit monitoring Output power monitoring Self check control Safety EN60601 1 EN60601 1 2 EN60601 2 2 Electrical Class CF MDD 93 42 EC Class II b automatic Start Stop coagulation functions SURGEON AND PATIENT TOTAL SAFETY acceptability of contact impedance between patient body and return electrode continuously monitored by Skin Plate Electronic Control SPEC H F Leakage currents continuously monitored mains fluctuation automatically compensated before delivery of HF power PERSONALIZED PROCEDURES independent choice of coagulation currents and power levels by each of two operators up to 10 procedures can be configured and re called EXTENSION DRIVER AND INTERLOCK SIGNALS driven output connection to external Argon Plasma unit and Smoke Evacuator unit AUTOMATIC SELF DIAGNOSIS auto
8. 0 1000 15 MDD 93 42 EEC Class Il b Maximum output power BIPOLAR CUT W 120 2500 15 Patient circuit Working frequency 600 kHz Duty cycle action pause in seconds 10 30 155 BM MONOPOLAR AND BIPOLAR ELECTROSURGICAL UNITS 120W AND 200W fan Mima f 30631 S u e eee e 30631 DIATERMO MB 120 FLASH e 30633 DIATERMO MB 200 FLASH MB FLASH are a High Frequency ElectroSurgical equipment suitable for precision monopolar and bipolar surgery and micro surgery without tissue alterations MB FLASH allow surgical treatments with programmable timer operations up to milliseconds or with traditional mode MB FLASH allow pure CUT cut coagulation BLEND incision with reduced production of eschar ENHANCED superficial coagulation FORCED COAG deep coagulation in absence of necrosis SOFT COAG and BIPOLAR coagulation Digital reading of delivered power and the surveillance through microcontroller of the operational functions assure absolute reliability of the working conditions MB FLASH allow a highly professional surgery through ergonomic and safety features TECHNICAL SPECIFICATIONS MB 120F MB 200F Max output power CUT 120 W 250 0 200 W 250 0 Max output power BLEND 90 W 200 OQ 120 W 200 0 Max output power ENHANCED 90 W 2500 120 W 250 Q Max output power FORCED COAG 80 W 150Q 150 W 1500 Max output power SOFT COAG 60 W 100Q 90 W 100 0 Max output power BIPOLAR COAG 60 W 50 Q 80 W 50 Q Working frequency 600 kHz 600 kHz RF power pulse
9. 1 30651 Tip size mm round points mm round points mm round points 2mm round points _ _ xm mm round points mm round points mm round points mm round points mm round points 0 3 mm points 0 3 mm points 0 3 mm points mm round points 0 25 mm points 0 25 mm points 0 5mm points 0 5 mm points 0 5 mm points Straight tip Straight forceps 30656 Irrigation UNIVERSAL EUROPEAN CONNECTION Our forceps are provided with a standard European connection enabling their use with GIMA Diatermo and electrosurgery units from the main European manufacturers 30622 Length cm inches e 12 1 cm 14 cm 15 9 cm 17 8 cm 434 52 6 7 CUSHING 30623 JANSEN BAYONET aE Straight tip C 0120 Size GENERAL PLASTIC 1 mm round points EDA GENERAL PLASTIC 0 5 mm points ADSON GENERAL PLASTIC 1mm round points UNIVERSAL US GENERAL PLASTIC 1mm round points CONNECTOR Length Tip style cm inches 15 6 STRAIGHT 18 7 STRAIGHT 20 73 STRAIGHT 18 7 ANGLED 20 734 ANGLED 18 7 STRAIGHT 20 73 STRAIGHT 11 5 4 5 STRAIGHT 11 5 4 5 ANGLED 12 1 4 STRAIGHT Tip size mm mm mm mm mm mm mm i d 0 7 mm 0 7 mm 1mm C Eom coagulation A tip material with excellent thermal properties prevents the sticking of tissues The non stick effect is permanent and will not reduce with the use of forceps EE Se 30473 30474
10. 518 single use FT pin 4mm plug for above handles mM MONOPOLAR FORCEPS SCISSORS AND CABLES 30612 _tip 2mm 30611 PL oe Metzenbaum GIMA code 30610 30611 30612 30613 30614 30615 Monopolar forceps are provided monopolar cables units in the market INSULATED MONOPOLAR INSTRUMENTS Monopolar cable 4mm pin Mc INDOE straight monopolar forceps 15 cm 6 Bayonet monopolar forceps 20 cm 7 1 2 Monopolar scissors straight 18 cm 7 Metzenbaum monopolar scissors straight 18 cm 7 Metzenbaum monopolar scissors curved 18 cm 7 30539 screw type Tripolar universal Valleylab C Eo with a 4mm connection for standard These can be used with all Gima LED Erbe and many other electrosurgical 160 mM UNIVERSAL HIGH QUALITY INSULATED BIPOLAR FORCEPS ELRO EAN CONNECTOR BIPOLAR FORGE Binner electrodes for ENT application GIMA code 30645 30646 30647 30648 30650 30656 30651 30658 30652 30653 30657 30654 30655 30660 30661 30662 30664 30665 30666 30667 30668 30647 30648 Ophthalmic Micro forceps ISO 9001 C alee FDA ISO 13485 s Length Model Ss cm inches BINNER EU 22cm 8Y2 BINNER EU 18cm 7 BINNER EU 18cm 7 BINNER EU 19cm 7 STRAIGHT EU 18cm 7 STRAIGHT with irrigation EU 18cm 7 STRAIGHT EU 20cm 73 4 STRAIGHT EU 20cm 73 4 STRAIGHT EU 18cm 7 STRAIGHT
11. 85x239 190x85x239 e 30625 DIATERMO 50 monopolar FA DA I A E E a e 30626 DIATERMO 80 monopolar a joie Mep Controls a E monitoring Output power monitoring suitable for minor monopolar surgery MDD 93 42 EC Class Il b DIATERMO 50 and 80 are radiofrequency electrosurgical units C nog1 Safety EN60601 1 EN60601 1 2 EN60601 2 2 Electrical Class I CF Diatermo 50 through the function selection makes pure cut cut coagulation CUT 1 CUT 2 and pure coagulation possible STANDARD ACCESSORIES Diatermo 80 has a multifunction selector which makes cutting Single use handle CUT cut coagulation BLEND coagulation COAG and micro a e foot switch 30577 l l etal plate 30566 cable 30559 coagulation MICRO possible The one board microcontroller Kit of 6 short autoclavable electrodes 2 4 mm length 5 cm and digital display guarantee high safety and reliability under 30501 2 4 7 9 10 see page 159 any conditions They offer outstanding professional surgical Power cable 2 m Shuko plug results due to their ergonomic and superior safety features User manual English Italian available on request French Spanish 154 MONO BIPOLAR ELECTROSURGICAL UNIT 200W icoscory FIRST AID GASTROENTEROLOGY GENERAL SURGERY GYNAECOLOGY NEUROSURGERY ORTHOPEDICS OTORHINOLARYNGOLOGY PEDIATRIC SURGERY PLASTIC SURGERY PNEUMOLOGY UROLOGY VASCULAR SURGERY VETERINARY e 30630 DIATERMO MB 200D 200 Watt minimally invasive surgi
12. ATOR An aspiration and filtering system for the smokes produced during the surgical procedures The smokes generated during the surgical procedures have a bad strong and persistent smell These smokes consist of water vapour organic gas visible or invisible solid particles and viral parts So a good aspiration and filtration eliminates bad smells reduce the bacteriological and or viral risks and improves vision of the zone of the operation area during the laparoscopic procedures Activation of the aspiration can be Automatic through the remote electronic system of automatic survey of the activation of the high frequency electrosurgical unit Manual Through a foot switch optional The aspiration flow can be adjusted to suit the specific needs For laparoscopic procedures there is a specific function L TECHNICAL SPECIFICATIONS 230 V 115 V on request 50 60 Hz 800 VA 1000 LPM 35 CFM 250 mbar 83 in H O ULPA with active carbons Mains voltage Mains frequency Electrical input power Max vacuum flow rate Max static suction Filter type Filter efficency 99999 Particles diameter 0 12 micron Size 370x144x319 mm Weight 4kg STANDARD ACCESSORIES ULPA filter 5 hours blue Aspiration kit Q filter pipe 22 mm length 2 4 m 4 handle aspiration kit adapter 10 mm 22 mm pipe 10 mm length 1 8 m clip to fix the pipe to the handle adapter to the handle Power cable quickly selectable Smo
13. E BIPOLAR CABLES FOR MAJOR BRANDS Quality highly flexible silicone bipolar cables Autoclavable at 134 C up to 70 times 3 m long 10 Suitable for most generators with connector for European or US forceps e 30642 BIPOLAR CABLE ADAPTOR 30642 30640 30637 30643 30644 30639 BIPOLAR CABLE 30638 Connector to EU or US forceps g EU E US H EU E US nE EU E EU Compatibility 4 mm banana plug GIMA MB122 MB 122 D MARTIN ERBE list for brand and model GIMA MB120F 200F 200D MB132 MB160 MB 160D BERTHOLD SELECT 240 250 300D 380 400 400D MB200 MB202 AESCULAP DOWN VALLEY LAB WOLF SIEMENS CONMED CODMAN OLYMPUS E FOOTSWITCHES AND BOARDS coe FOOTSWITCHES FOR 50 80 106 MB 120 122 132 160 200 202 30577 Waterproof MB footswitch 2m cable 30578 Waterproof MB footswitch 3m cable ANTIEXPLOSION FOOTSWITCH FOR MB 120 122 132 160 200 202 30602 Double antiexplosion water proof MB footswitch ANTIEXPLOSION FOOTSWITCHES FOR MB 240 250 300D 380 400 400D 30603 Double antiexplosion water proof footswitch MB240 380 30604 Double antiexplosion water proof footswitch MB250 400 300D 400D MAIN BOARD 30557 Main board specify model and serial number of diatermo with order 30558 Output board for MB 240 250 380 400 specify as above 30602 3 4 It allows selection from pedal of CUT and COAG functions Antiexplosion and waterproof Mm ELECTROSURGERY SMOKE EVACUATOR e 30450 SMOKE EVACU
14. EU 20cm 73 4 BAYONET EU 16 5cm 6 BAYONET EU 18cm 7 BAYONET EU 20cm 734 STRAIGHT EU 18cm 7 STRAIGHT EU 18cm 7 STRAIGHT EU 20cm 734 ADSON EU 12 1cm 6 JEWELER 5 EU 11 5 cm 42 JEWELER 5 EU 11 5 cm 42 STRAIGHT EU 15cm 6 STRAIGHT 7 15cm 6 Mc PHERSON 10 2cm 4 30669 EE US CONNECTOR BIPOLAR roncers HE T 30621 GIMA code 30620 30621 30622 30623 E EUROPEAN NON STICK BIPOLAR FORCEPS SEMKIN Model ADSON SEMKIN CUSHING JANSEN BAYONET amp amp Connector Cc N NON STICK BIPOLAR FORCEPS Thanks to new Ag Tech non stick technology the forceps stay clean virtually eliminating the need for cleaning during GIMA code 30460 30461 30462 30464 30465 30468 30469 30472 30473 30474 161 D Model zZ J STRAIGHT STRAIGHT STRAIGHT STRAIGHT STRAIGHT BAYONET BAYONET JEWELER JEWELER ADSON EU JEWELER 30654 MC PHERSON 30669 a Bayonet forceps 30665 JEWELER 30666 Tip style Application ANGLED ENT STRAIGHT ENT ANGLED ENT ANGLED 45 ENT STRAIGHT GENERAL STRAIGHT GENERAL STRAIGHT GENERAL STRAIGHT GENERAL ANGLED GENERAL ANGLED GENERAL STRAIGHT GENERAL STRAIGHT GENERAL STRAIGHT GENERAL ANGLED GENERAL STRAIGHT GENERAL STRAIGHT GENERAL STRAIGHT GENERAL STRAIGHT OPHTHALMIC MICRO ANGLED OPHTHALMIC MICRO STRAIGHT OPHTHALMIC MICRO ANGLED OPHTHALMIC MICRO STRAIGHT OPHTHALMIC MICRO 30667 General forceps Angled tip 1 1
15. GY VETERINARY GASTROENTEROLOGY d ORTHOPEDICS Diatermo MB 120 only Diatermo MB 200 only Connection of neutral electrode is constantly monitored Safety control of patient plate contact using split neutral electrode Possibility to control the output functions and the delivery of output power by handle allows surgical operation without diverting attention from the surgical field Features patient to plate contact control split return electrode use allowed minimally invasive surgical treatment allowed Monopolar and Bipolar indipendent output auto Start Stop in Bipolar Coag working condition planning power delivery by pedal and or handle digital regulation and indication of the output power sound level control adjustable power increment RF power pulse emission time setting RF power pulse interval setting STANDARD ACCESSORIES MB two button autoclave handle Waterproof MB footswitch 30577 MB metal plate neutral electrode 30566 and cable 30559 2 disposable ground pads 30562 Kit 10 short standard electrodes 2 4 mm 3 needle 3 blade 3 ball electrodes 7 cm Power cable 5m Microsurgery handle 30552 Microsurgery needles 10 pieces Manual English Italian J ia csa MED CE 30633 e 30552 HANDPIECE FOR DEPILATION e 30560 DEPILATION OR MICROSURGERY NEEDLES e 30577 FOOTSWITCH 156 BM HOSPITAL HF ELECTROSURGICAL UNITS 240 AND 380 WATT f MATER
16. IMES sa rer E SINGLE USE STERILE ELECTRODES 2 4 mm GIMA_ Reference SINGLE USE ELECTRODES 2 4mm _ Reference GIMA N 13 See code number minimum order 24 pcs number code Length N 11 length 7 cm Sterile electrode length 15 cm 7M 12 30670 13 Needle electrode sterile electrode 33 30674 an Length 30671 11 Blade electrode sterile 31 30675 inanmam E N 34 13cm 30672 12 Ball 4 mm electrode sterile 32 30676 i Sterile electrode length 13 cm N 33 15cm Loop electrode 15mm x8 mm 34 30678 N 32 15cm E SINGLE USE METAL AND RUBBER PLATES 30574 rem rubber plate 30492 30493 30490 30494 30566 Adult Adult REM Pediatric disposable Adult pediatric metal plate disposable plate disposable plate plate disposable plate 30573 a e 30492 DISPOSABLE GROUND PADS WITH SOLID GEL adult rubber plate 20x15 cm 30490 DISPOSABLE GROUND PADS WITH SOLID GEL pediatric 30493 REM DISPOSABLE GROUND PADS WITH SOLID GEL adult 39573 RUBBER PLATE 20x15 cm without cable Adult ground plate with solid gel Single use plate individually packed 30574 REM RUBBER PLATE 20x15 cm without cable e 30563 CABLE FOR PLATES 5 m Universal cable to connect plates 30490 34095 to diatermo e 30575 CABLE FOR RUBBER PLATES Safety lock with universal connection bipolar 6 3 mm plug 30566 METAL PLATE without cable e 30494 DISPOSABLE NON WOVEN GROUND PADS adult ped 30563 CABLE FOR PLATES 5 m e 30495 REM
17. MO ME Skin Plate Flactronic Control CONTEMPORARY DUAL MODE MB 240 and 380 can be used in the same time in monopolar mode by handle and bipolar mode by footswitch e 30690 DIATERMO MB 240 C E 005 Mi m CSQ OA Wil meo 30690 e 30692 DIATERMO MB 380 These HF electrosurgical units can be used to execute monopolar and bipolar surgery when high precision and reliability are essential as in the endoscopic surgery EASY TO USE Graphic icons allow an easy selection of the operation mode All operating conditions and selected output controls are represented by bright digital indications CUT The monopolar cut can be performed by pure sine current to obtain an incision with a minimum damage for the adjacent tissues and sure recovery for first intention Two different modes of modulation allow to reduce bleeding during monopolar cut In the bipolar mode the cut can be effected by pure sine current HEMOSTASIS When the surgical action requires the obliteration of a blood vessel the availability of currents with different coagulative powers enables this type of work both with monopolar and bipolar surgery FULGURATION When it is necessary to cause a superficial necrosis of wide areas protecting the deeper tissues a special coagulant current that dehydrates the superficial layer of the tissue and reduces the possibility to damage those beneath is available for the operation OUTPUT CONTROL Output power levels are adjustable th
18. NGOLOGY UROLOGY f GYNAECOLOGY VETERINARY DENTISTRY Diatermo MB160 only Diatermo MB120 only e 30628 DIATERMO MB 120D mono bipolar 120 W e 30629 DIATERMO MB 160D mono bipolar 160 W C G nee S MED MB 120D and MB 160D are high frequency electrosurgical units suitable for minor and medium surgery he iiis Er Net 4 MB allow pure CUT cut coagulation BLEND superficial TECHNICAL SPECIFICATIONS coagulation FORCED COAG deep coagulation in absence of MB 120D MB 160D necrosis SOFT COAG and with forceps BIPOLAR coagulation Max output power CUT 120 W 250 Q 160 W 250 Q The digital reading of delivered power and the monitoring Max output power BLEND 90 W 200 Q 120 W 200 Q of operative function by microcontroller guarantees absolute Max output power FORCED COAG 80 W 150 O 100 W 150 Q reliability of working conditions Max output power SOFT COAG 60 W 100 Q 80 W 100 Q MB allow a highly professional surgery through ergonomic Tecate ag Sey i Se as s and safety features The connection of neutral electrode is Patient circuit FE F constantly monitored Safety control of patient plate contact Selectable input voltage 115 230 Vac 115 230 Vac using split neutral electrode Mains frequency 50 60 Hz 50 60 Hz Possibility to control the output functions and the delivery of Electrical input power 300 VA 350 VA output power by the handle allows the surgical operation OR nary eee a eee without diverting at
19. al plate Power cable 2 m Kit of 6 MB 122 or 10 MB 160 short autoclavable electrodes diam 2 4 mm User manual available in English Spanish Italian French Polish PDE aTi r SOFT HLTH DOAL GWI te ee COAG TECHNICAL SPECIFICATIONS Minimum preselectable power Level step Maximum output power CUT W Maximum output power BLEND W Maximum output power COAG FORCED W 80 Maximum output power COAG SOFT W 60 Maximum output power BIPOLAR W Working frequency Weight Kg Size LxHxD mm Operating voltage switchable Mains frequency Hz Fuses 230Vac 5x20 TIMED Fuses 115Vac 5x20 TIMED Electrical input power VA Electrical input current 230Vac A Electrical input current 115Vac A Five steps adjustable sound level from 55 to 75dBA Self check Power accuracy output warning Split or not split patient plate allowed Last working condition storing Electrical Class EN60601 1 MDD 93 42 EEC Class Patient circuit MB122 0 1 120 2500 90 2000 1500 1000 40 1000 600 kHz 7 260x110x265 115 230 50 60 2x 3 15A 2x 6 3A 300 1 3 2 6 CF IB mM MONOPOLAR ELECTROSURGERY UNIT 50W TECHNICAL SPECIFICATIONS Let Agl hiPOLAg SiG TMA e 30516 DIATERMO 106 50W monopolar This HF electrosurgery unit is particularly suitable for small operations and is recommended for dentistry first aid and dermatology work It offers precision of cut and immediate coagulati
20. cal T Net brite IQ aad MB 200 is a high frequency electrosurgical equipment suitable for light treatment allowed w Sacro and medium surgery allows minimally invasive surgical procedure of monopolar and Bipolar indipendent output resection evaporation and coagulation auto Start Stop in Bipolar Coag MB 200 allows pure CUT Cut Coagulation BLEND incision with working condition planning C 0051 reduced production of eschar ENHANCED superficial coagulation power delivery by pedal and or handle FORCED COAG deep coagulation in absence of necrosis SOFT COAG digital regulation and indication of the output power and BIPOLAR coagulation Digital reading of delivered power and sound level control surveillance through microcontroller of the operational functions adjustable power increment assure absolute reliability of working conditions TECHNICAL SPECIFICATIONS MB 200 allows a highly professional surgery through ergonomic and Maximum output power CUT 200W 2500 safety features The connection of neutral electrode is constantly er Mani Tit Cpu porie EAko dae igi 2 oa 0e monitored Safety control of patient plate contact using split neutral ee Se Oe EnD TZON 200o N aximum output power FORCED COAG 150W 1500 electrode Possibility to control the output functions and the delivery Maximum output power SOFT COAG 90W 1000 of output power by the handle allows the surgical operation without Maximum output power BIPOLAR COAG 80W 500 div
21. e and blade electrode code number autoclavable at 121 C length width depth gt 30482 NEEDLE ELECTRODE 4mm 30686 50 Square loop electrode 13cm 10mm 8mm e 30483 BLADE ELECTRODE 4mm eae 30687 51 Loop electrode 13cm 15mm 8mm o 39484 BALL ELECTRODE 4mm 30688 52 Loop electrode 13cm 20mm 10mm S S electrodes autoclavable 150 times Sold in Hex of 5 Length 5 5 cm Mm AUTOCLAVABLE ELECTRODES 2 4 mm GIMA_ Reference code number AUTOCLAVABLE ELECTRODES 2 4mm Reference GIMA 4 2 3 4 5 6 7 8 9 10 145 16 17 number code length 5 cm minimum order 6 pcs length 10 cm 5 cm long electrodes reference number Jc 30501 1 Electrode wire 0 2 straight 21 30521 30502 2 Electrode wire 0 2 angled 45 22 30522 i 30503 3 Electrode bend 4 straight 23 30523 30504 4 Electrode bend 8 straight 24 30524 ii 30505 5 Electrode hook angled 45 25 30525 30506 6 Electrode wire 1 mm angled 45 26 30526 30507 7 Electrode straight slip knot straight 27 30527 30508 8 Electrode angled slip knot straight 28 30528 30509 9 Electrode ball point 3mm angled45 29 30529 30510 10 Electrode ball point 3 mm straight 30 30530 30500 SET Set of 10 electrodes SET 30531 length 7 cm minimum order 10 pcs length 15 cm 10 cm long electrodes reference number 15 cm 30511 15 Needle electrode 35 30532 21 22 23 24 25 26 27 28 29 30 35 36 37 30512 16 Blade electrode 36 30533 30513 17 Ball electrode 37 30534 _AUTOCLAVABLE 100 T
22. emission time 10ms 30sec 10ms 30sec RF power pulse interval 1 9 1 9 Patient circuit F F Selectable input voltage 115 230 Vac 115 230 Vac Mains frequency 50 60 Hz 50 60 Hz Electrical input power 300 VA 350 VA Size WxHxD mm 370x144x319 370x144x319 Weight 6 kg 6 kg Controls Patient Plate circuit monitoring Output power monitoring Self check control Safety EN60601 1 EN60601 1 2 EN60601 2 2 Electrical Class CF MDD 93 42 EC Class II b m ELECTRODEPILATOR e 28340 ELECTRO DEPILATOR 400 This device ensures a definitive depilation with thermolitic method It delivers a current of radiofrequency to cause the heating and consequent coagulation of the papilla reached through the introduction of a needle into the follicle of the hair Provided with highly reliable electronic integrated components with RF intensity adjustable with continuity and luminous working signal It comes complete with footswitch handpiece for depilation depilation needle and power cable 2 m TECHNICAL SPECIFICATIONS RF output frequency 1 9 10 MHz Modulation sinusoidal Maximum output power 7 2Watt Size 260x265xh 110 mm Weight 4 kg Operating voltage 115 230 V 50 60 Hz switchable Norms CEI 62 39 Class I BF OUTPATIENT SURGERY DERMATOLOGY VASCULAR SURGERY GYNECOLOGY DENTAL OTORHINOLARYNGOLOGY PEDIATRIC SURGERY FIRST AID PLASTIC SURGERY ENDOSCOPY OPHTHALMOLOGY NEUROSURGERY PODIATRY PNEUMOLOGY UROLO
23. erting attention from the surgical field Working frequency 600 kHz patient to plate contact control Patient circuit F split return electrode use Mains voltage 115 230 Vac Mains frequency 50 60 Hz STANDARD ACCESSORIES Electrical input power 350 VA MB two button handle autoclavable code 30547 Size WxHxD mm 370x144x319 Waterproof MB foot switch 30577 Weight 6 kgs MB flat neutral metal plate 30566 with cable 30559 Controls Patient Plate circuit monitoring Output power monitoring Kit 10 short standard electrodes diam 2 4 mm Self check control 3 needle 3 blade 3 ball electrodes 7 cm Safety EN60601 1 EN60601 1 2 EN60601 2 2 Electrical Class CF Power cable 5m Manual available in English Italian MDD 93 42 EC Class II b E DIATERMO MB 200 MONO BIPOLAR 200W e 30542 DIATERMO MB 200 200 Watts DIATERMO MB200 is a HF electrosurgical unit suitable to perform middle monopolar or bipolar electrosurgery The available waveforms and peak voltage value as well as the accurate HF leakage current operation for polypectomy TURP intrauterine resections endometriosis excision etc The units allow the accurate preset of the output power with as low as 1 Watt resolution and to perform coagulation by high crest factor current to get an elevated thermal effect as well as with low voltage low crest factor current to get coagulation in absence of carbonization Ten different programs related to ten different operative conditio
24. estruction or removal of living tissue Effective use on 9 benigne lesion types Verruca Vulgaris Common Warts Verruca Plantaris Plantar Warts Molluscum Contagiosum Lentigo Age Spots INVERT Condyloma Genital Warts a custom applicator canister a frozen Seborrheic Keratosis 2 mm disposable applicator for small lesions press valve until for 15 seconds for optimal applicator to lesion Acrochordon Skin Tags 5 mm disposable applicator for large lesions droplets start to form freezing temperature for 15 40 seconds Verruca Plana Flat Warts Saturated 2 mm applicators will stay cold for 90 seconds Actinic keratosis Facial and Non Facial Saturated 5 mm applicators will stay cold for 120 seconds E CHANGE A TIP CAUTERIES WITH HIGH TEMPERATURES BOVIE CAUTERIES made in USA interchangeable sterile tips gre replaceable batteries a cz reusable handles 30590 no sterilization necessary Fine tip not sterile included is a GIMA INTERCHANGEABLE TIP CAUTERIES Recommended code MINIMUM ORDER 10 TIPS ae 305950 30590 Cautery handle AA tip included All tips ao i a C 0413 30593 High temp loop tip sterile DER ENT 30594 30594 High temp 2 flex loop tip sterile GYN ENT P 30595 High temp 5 loop tip long size sterile GYNAECOLOGY l 30596 High temp fine tip sterile DER CARDIO 30596 30593 E REUSABLE HIGH TEMPERATURE CAUTERY WITH REPLACEABLE TIP CAUTERIES
25. ke evacuator has an electronic control of the aspiration with the indication of the wearing status of the filters There are two different kinds of quickly replaceable ULPA type filters with active carbons the BLUE filter is the first filter and it is included with the unit for an initial time of use 5 hours the RED filter is an optional spare part developed for a long time use 20 hours They have connector of 7 8 e 30452 ULPA FILTER 20 hours RED spare e 30453 ASPIRATION KIT box of 6 e 30454 HANDLE ASPIRATION KIT sterile box of 12 e 30577 WATERPROOF MB FOOTSWITCH 2 m ULPA filter blue E i 30454 ie Handle aspiration kit Power cable w 162 Supplied with box and manual in GB FR IT DE ES NL PL Re ee eee Sn e 30587 HISTOFREEZER kit with applicator 2 mm a 170 ml aerosol bottle and 60 applicators 2 mm 7 i Raes e 30588 HISTOFREEZER kit with applicator 5 mm isto icto lictofreezer 170 ml aerosol bottle and 50 applicators 5 mm H Hi 5 Histofr e 30586 HISTOFREEZER large kit mixed applicators ta 170 ml aerosol bottle 30 applicators 2 mm EA Si 30 applicators 5 mm A r3 e 30585 HISTOFREEZER mini kit mixed applicators A One 80 ml aerosol bottle 15 applicators 2 mm 15 applicators 5 mm The Histofreezer portable cryosurgical system is a low cost highly effective cryosurgical agent This therapeutic treatment makes use of local freezing for the controlled d
26. matic diagnostic control of the complete functionality of electronic unit and connected accessories with coded report of failures SUITABLE IN OUTPATIENT SURGERY GENERAL SURGERY PAEDIATRIC SURGERY PLASTIC SURGERY THORAX SURGERY VASCULAR SURGERY DERMATOLOGY ENDOSCOPY GASTROENTEROLOGY GYNAECOLOGY NEUROSURGERY ORTHOPEDICS OTORHINOLARINGOLOGY PNEUMOLOGY UROLOGY VETERINARY J 30634 STANDARD ACCESSORIES 1 Power supply cord 5 m 1 Two button handle autoclavable code 30539 MB 400 5 Two button handle cold sterilizable code 30551 400 W 300 1 Cable for flat plate 30559 se y l x gt 5 Rem disposable ground pads 30565 500 W 3000 2 HP double Water proof foot switch 250 W 500 Q 3 Short general surgery blade electrode 7 cm 250 W 300 Q 3 Long general surgery blade electrode 16 cm 120 W 500 Q 3 Short general surgery ball electrode 4 mm 6 cm 120 W 200 Q 1 Electrode brush 100 W 2000 Q 1 User manual Italian English 100 W 20000 1 Service manual Italian English 95 W 1500 95 W 1500 95 W 150 60 W 1500 90 W 1500 70 W 1000 425 kHz 525 kHz F 115 230 Vac 50 60 Hz 1000 VA 470x150x400 17 5 Kgs 158 Width m LOOP ELECTRODES a 4mm ELECTRODES AnD eo 4 mm e 30480 AUTOCLAVABLE MB HANDLE 4 mm 100 times Autoclavable handle up to 100 times for 4 mm shaft GIMA Reference OOP ELECTRODES 2 4mm Shaft Electrode Electrode electrodes with 3 m silicone cabl
27. ns could be stored and easily recalled by the surgeon The use of either split or normal neutral plates are allowed A special electronic circuit Skin Plate Electronic Control continuously checks if the plate is DIATERMO MB 200 STANDARD ACCESSORIES MB two button handle autoclavable code 30547 handle in beside picture is not correct MB waterproof foot switch 30577 usable in alternative to handle safely connected to the patient and detects unwanted short MB flat neutral metal plate with cable circuit in the connecting cable An over time warning OVT is Kit 10 short standard electrodes diam 2 4 mm C 0051 provided to prevent excessive heating of the tissue around the Power cable 2 m Manual available in English Italian surgical target due to too long current delivery time TECHNICAL SPECIFICATIONS Crest factor Weight kg 8 Maximum output power CUT W 200 2500 1 5 Size LxHxD mm 360x150x265 Maximum output power CUT 90 W 200 2500 1 6 Selectable mains power Vac 115 230 Maximum output power CUT 80 W 200 2500 t7 Mains frequency Hz 50 60 Maximum output power CUT 70 W 200 2500 1 8 Fuses 115Vac 230Vac 5x20 TIMED 2x 6 3A 2x 3 15A Maximum output power BLEND W 120 2000 2 1 Power accuracy output warning system Maximum output power COAG FORCED W 150 1500 2 0 Split or not split patient plate allowed Maximum output power COAG SOFT W 90 1000 7 Electrical Class EN60601 1 I CF Maximum output power BIPOLAR COAG W 10
28. on and give excellent results in a large range of applications from uterine coagulation to microcoagulation in dermatology The modes of operation CUT COAG and 153 Coe MED C Em Output power CUT COAG BLEND Working frequency 50W 400 ohm 40W 400 ohm 45W 400 ohm 600 kHz 10 Size 180x180xh 100 mm Operating Voltage 115 230 V 50 60 Hz switchable Electric input power 90 VA Alarm for overheating Made in Italy DIATERMO MB 122 AND MB 160 MONO BIPOLAR 120w 160Ww MB160 Crest Factor 0 1 160 2500 15 120 2000 2 1 100 1500 2 0 80 1000 17 60 1000 15 600 kHz 7 260x110x265 115 230 50 60 2x 3 15A 2x 6 3A 350 les 3 I CF Il B Weight 2 8 kg Fuse 2x1 AT Footswitch operating Norms EN60601 1Class CF EN 60601 1 2 93 42 EEC Class IIb Warranty 12 months STANDARD ACCESSORIES KIRKY single use handle without buttons Standard foot switch 30577 Rod neutral electrode and cable Kit of 6 short autoclavable electrodes 2 4 mm length 5 cm Power cable 2 m Shuko plug User manual available in English Italian Spanish French BLEND can be easily selected by a switch on the front panel The complete isolation between patient and the unit and strict respect of international norms guarantee total safety MONO BIPOLAR ELECTROSURGICAL UNITS 120W AND 160W CASUALTY SURGERY PEDIATRIC SURGERY PLASTIC SURGERY VASCULAR SURGERY DERMATOLOGY FIRST AID OTORHINOLARY
29. rough incremental biai ae r Til oc A special electronic circuit Skin Plate Electronic Control continuously warns the plate to patient contact safety and unwanted short circuit in the connec ting cable encoders that allow the exact pre sets and repetition of the values The output function is linearized and controlled by ultra modern electronic micro controllers which will interrupt power if any alarm condition happens SAFETY OF USE Circuits dedicated to the safety of operator and patient are the priority This ensure the leakage current is kept well under the international requirements values whatever the output condition Monopolar and bipolar output circuits are completely floating and the use of the defibrillator is allowed while the reference plate patient is connected RELIABILITY DIATERMO MB uses all solid state electronic circuits and is made with interchangeable units for a fast and effective maintenance Automatic control circuits protect the units from damage also in case of repeated improper use 380 mm wo eee ie ee mn aa G o F s a7_ a f x _ emjee 30692 TECHNICAL SPECIFICATIONS DIATERMO MB 240 DIATERMO MB 380 Activation devices Bipolar footswitch Dual bipolar footswitch Working Max power monopolar manual frequency 240 MB 380 Monopolar footswitch Monopolar output 475 kHz manual Cut output 250W 375W Mains 115 230 Vac 50 60 Hz C
30. tention from the surgical field Controls Patient Plate circuit monitoring Output power monitoring Features Self check control minimum Invasive surgery Safety EN60601 1 EN60601 1 2 EN60601 2 2 Electrical Class CF possibility to use bipolar forceps MDD 93 42 EC Class Il b possibility to use split neutral electrodes memorization of the last used settings tivation by pedal and or handle MP ange e Baon nane A power ac f y P mre i Waterproof foot switch 30577 usable as alternative to handle digital adjustment and indication of the output power MB flat neutral plate 30566 and cable 30559 adjustment of the acoustic indicator intensity Kit of 10 short autoclavable electrodes diam 2 4 mm Power cable 2 m User manual English Italian available on request French Spanish Polish mM MONOPOLAR ELECTROSURGERY UNITS 50W AND 80W TECHNICAL SPECIFICATIONS STANDARD ACCESSORIES DENTISTRY 50 80 DERMATOLOGY Max output power CUT 50 W 400 Q 80 W 400 Q OUT PATIENT SURGERY f Max output power CUT COAG1 45 W 4000 FIRST AID Max output power CUT COAG2 40 W 4000 Max output power BLEND 60 W 400 V sain Sure Max output power COAG 40 W 400 O 50 W 400 0 Max output power MICRO 20 W 600 Q Diatermo 80 only Working frequency 600 kHz 700 kHz Patient circuit F F i Selectable input voltage 115 230 Vac 115 230 Vac Mains frequency 50 60 Hz 50 60 Hz Electrical input power 200 VA 230 VA e Size WxHxD mm 190x
31. ut coag 1 output 225W 340W Absorption 800 VA Cut coag 2 output 200W 300W Class CF Coag 1 output 150W 225W Weight 15 kg Coag 2 output 100VW 150W Size 370x470xh 150 mm Coag 3 output spray 80W Warranty 12 months Bipolar output 525 kHz accessories not included Cut output 90W Norms IEC 601 2 2 IEC 601 1 Coag output 80W CE 93 42 EEC m LAPAROSCOPIC ELECTRODES o A 30606 m 30607 30605 157 Laparoscopic electrodes without suction for use with Diatermo MB 240 250 300 380 400 with connecting cable 4 mm 30609 STANDARD ACCESSORIES 1 Power supply cord SIEM CEE 5 m Peak to peak Load 1 Two button handle autoclavable code 30547 voltage resistance 5 Two button handle cold sterilizable 1 Cable for disposable plate 1 4 kV 300 Ohm 5 Disposable plate 1 4 kV 300 Ohm 1 Water proof double foot switch 1 4 kV 300 Ohm 3 Short general surgery blade electrode 1 4 kV 300 Ohm 3 Long general surgery blade electrode 1 4 kV 300 Ohm 3 Short general surgery needle electrode A2kV 2000 Ohm 3 Short general surgery ball electrode 1 User manual Italian English Spanish 0 5 kV 100 Ohm 1 Service manual Italian English 0 5 kV 100 Ohm GIMA eee LAPAROSCOPIC ELECTRODES 30605 _ L Hook electrode 36 cm 30606 J Hook electrode 36 cm 30607 Spatula electrode 36 cm 30609 Monopolar cable 4mm M F To generator B HIGH POWER ELECTROSURGICAL UNITS 300 AND 400 WATT e 30634 DIATERMO MB 300D e

Download Pdf Manuals

image

Related Search

electrosurgery electrosurgery electrosurgery dental electrosurgery unit electrosurgery machine electrosurgery vs electrocautery electrosurgery cpt code electrosurgery for warts electrosurgery tips electrosurgery device electrosurgery adalah electrosurgery generator electrosurgery definition electrosurgery dental code electrosurgery unit dental

Related Contents

Untitled  Alarm Box User Manual  Install and user manual  User manual  WirelessGuide_XJH_ES - Support  PRIMERGY TX200 S4 - Fujitsu manual server    rechargeable usb electronics charger cargador de electrónica  Whirlpool WOD51ES4ES Use and Care Manual  Management and outcomes in digestive cancer surgery  