OPTI R Analyzer Quick Reference Guide

image

Contents

1. 770 510 4444 or e mail technicalsupport optimedical com Outside the USA Please contact your local OPTI Medical Distributor 2007 OPTI Medical Systems Inc y Installation Component OPTI is a registered trademark of OPTI Medical Systems Inc y Y Calibrator Fluid Pack Master Cal Cassette Power Control Gas Bottle Powerdown Shutdown AT7036 I Zi gt OPTIMedical kS OPTI R Analyzer Quick Reference Guide Patient Sampling Syringe Press lt Run Sample gt at the ready display Insert new syringe adaptor into the cassette port Mix and place sample syringe on syringe adaptor Press lt OK gt to start sample aspiration Remove sample syringe when prompted Press lt OK gt after the syringe has been removed Read results at the completion of the measurement Press lt Home gt to return to the ready screen or lt Patient Info gt to enter patient data PE Capillary 1 Press lt Run Sample gt at the ready display 2 Insert capillary tip into the cassette port 3 Press lt OK gt to start sample aspiration 4 Remove capillary when prompted 5 Press lt OK gt after the capillary has been removed 6 Read results at the completion of the measurement 7 Press lt Home gt to return to the ready screen Refer to the operators manual or service manual for detailed instructions ee a td ail tel Edt Patent Data or Pross Ho
2. Menu Structure Ready Menu Data Manager QC Manager y Run QC Setup QC Auto QC Controls Auto QC Controls l S Measurement a gt Patient Results Patient Entry G y x Measurement l Reports Statitstics Diagnostic Reports Configuration C C J i So 7 l Patient Patient Auto QC Auto QC Control Control Calibration Calibration Y E System ae v iF 1 Time and Date Diagnostics Setup Utilities 4 j 1 i i Consumable 7 nee Status Control Tests Utilities l l y Versions Pack Level Fan i Barcode T Patient Entry Temperature Cassette Valve Test Printer Meas Param LEDs QC Meas FSet Optics Calc Param Barometric Gas Level Flow Normal Pressure Pump Ranges Display Correlation Touch Units RS232 Security Ethernet Printer Hardware Language OPTI R Consumables Ref No E Ca Cassettes BP7601 Fluid Pack BP7092 Gas Bottle BP7001 Peristaltic Pump Kit BP7118 Calibrator Cassette BP7535 Printer Paper HP0070 Syringe Adaptors BP7600 OPTI Check Tri level HC7008 Technical Support To contact technical support for assistance Inside the USA 1 800 490 6784 or
3. e sensor cassette before it has expired will result in the prema ture expiration of the sensor cassette Oo 6 months Peristaltic Pump Kit Replacement Open the printer cover Remove the pump by grasping the sides and pulling straight up Ay Carefully remove pump seals with tweezers or hemostats Properly dispose of expired pump and pump seals Rotate the pump shaft until the flat edge aligns with the new pump roller Firmly press the pump down onto the shaft Next press down on the pump roller to finalize installation Open the SMC and remove the I O port seals with hemostats or tweezers Properly dispose of the expired seals 10 Insert the new seals with the round side up and press firmly into place 11 Refer to the provided insert sheet for additional instructions Fluid Pack Replacement Remove expired pack and replace protective cap Press lt Install Pack gt on the display a Remove the protective cap from the new pack Insert new pack into fluid pack receptacle After calibration run any two levels of OPTI check control material to complete installation 6 Refer to the provided insert sheet for additional instructions en a et ee Gas Bottle Replacement 1 Remove expired gas bottle by turning counter clockwise P rog ram min g Au to Q C 2 Press lt Install Gas gt on the display 3 Swipe the gas bottle barcode located on the provided insert sheet and remove gas bottle cap 1 Press lt QC Manager gt t
4. me for Ready Mana ronan Eosulta Ready TIG ii Aoe pH 7 188 Poo 30 6 mmHg PO 62 3 mmHg 142 1 mmolL 3 047 mmol CAUTION Handle and dispose of all biological samples in accordance with your facility s policies Obtain appropriate medical attention in the event of any exposure to biological samples since samples may transmit infectious diseases Use the products only as directed in the operators manual Consumable Replacement Maintenance Tasks Cassette Replacement Weekly Cleaning the Analyzer 1 Open cover and remove expired cassette 1 Clean the analyzer s surface using a mild detergent and a soft cloth 2 Properly dispose of used cassette 2 Clean the SMC with an ammonia based cleaner or alcohol with a lint free cloth 3 Press lt New Cassette gt on the display 4 Swipe the 2 two cassette barcodes 3 months Running the Calibrator Cassette 5 Open pouch wipe cassette and insert it into the SMC ee 6 Close cover to begin calibration L re lt Utilities gt and then select the utilities tab at the top of 7 Refer to the provided insert sheet for additional instructions Been 2 Press lt Calibrator gt to begin Follow the on screen directions to run the calibrator cassette 4 After the calibration is complete press lt Home gt to return to the ready screen NOTE OPTI Medical recommends the calibrator measurement be performed between sensor cassette replacements Removing th
5. o enter the QC menu 4 Insert gas bottle into the instrument and turn clockwise to tighten 2 Select lt Auto QC gt under the setup heading 5 When prompted New Gas Bottle reply Yes if bottle is new 3 At the first time row press lt Edit gt 6 Ifthe gas bottle is used reply No and enter the number of weeks in use 4 Enter the scheduled time for this QC measurement and press 7 Refer to the provided insert sheet for additional instructions lt OK gt 5 Now select the levels to be run by checking the appropriate level s 6 Continue by moving to the next row and following the above steps 7 To perform auto QC on Saturday or Sunday check the cor responding box 8 When complete press lt Save gt to save the changes to memory 9 Press lt Home gt when finished to return to the ready screen

Download Pdf Manuals

image

Related Search

Related Contents

En savoir plus  取付・取扱説明書PDF  cahier des charges relzone  Frigidaire FGBD2434PB Energy Guide  Manual - Spectrum Controls, Inc.  vc175 digital-multimeter vc175 digital multimeter  REMARQUE : la marque Allemande REVUE-FOTO  User Manual  Title: Stretching Mode D`emploi Author: Lydie Raisin  Siemens Gigaset 4070_75isdn  