Home
USER AND SERVICE MANUAL
Contents
1. A washable Soft Headband option is available for general purpose and universal use of the light RUN Turn on Nano by pressing the raised ON OFF button Adjust power levels by PRESSING AND HOLDING ON OFF button for 2 seconds Turn off anytime by pressing the ON OFF button again Light will remember the last power setting when turning on the next time Battery Indicator shows the status of the battery when the light turns on or off In case no lamp is connected the battery beeps and turns off automatically after a few seconds At low battery an audible beep alarms 1 minute before the light goes off To recharge simply plug in Power Adapter 5V charged WIRING to attach lamp wire to frame temple leg Use Shirt Wire Clip to fix the lamp wire on the collar of scrub on the back of your neck Angle Set cord to the male DC connector The battery charge indicator turns on while charging and turns off automatically when it is fully Angle set the lamp wire coming out of the Nano Headlamp to 7 conform to the contour of your loupe frame Use Wire Wrap Clip Wire Wrap Use Protection Cord to protect the lamp wire and extend the service life Minimize wire stress at the battery connection junction Avoid bending YES wire close to 90 degrees at the lamp wire to Protection Cord or Battery connection Place battery in one of the following configurations a P osition Battery Pack with the Battery Clip P ouch on the waist or belt of your scrub
2. pocket rim Route the wire straight up from your back Route the wire with minimum tension or stress at the Connector Wire J unction to extend wire lifetime Avoid bending 90 degrees at the junction b Place Battery Pack directly in your scrub pocket Make sure that Protection Cord is used Route the lamp wire with minimum tension or stress at the Connector Wire J unction to extend lamp wire lifetime Avoid bending 90 degrees at the Connector Wire J unction a Wire Clip H A SS Connector S E Wire E Junction LE a Protection Cord COMPOSITE FILTER Align the slot of the Composite Filter Clip to the Rim Ledge close to the front end of the Nano Headlamp housing Further align the Center Notch on the Headlamp to that of the Filter Wey Clip Snap on the Filter Clip for a secure fit TIPS Wire routing Route lamp wire to minimize stress DO NOT ROUTE OR BEND WIRE 90 DEGREES AT THE WIRE CONNECTOR UNCTION Use Protection Cord all the times to extend service life Battery Charge Battery Pack while not in use to extend battery life o _ Rim Ledge Clip Slot Center Notch Cleaning and Disinfecting Clean and disinfect Headlamp and Battery P ack with a soft cloth or tissue dampened with cleaning solution including Cavicide Lysol Isopropyl or Ethyl alcohol and equivalent AN Do not spray soak or autoclave Use Q tips to clean lens and electrical contacts by slightly damp
3. E 1825 Summit Ave 210 Molenstraat 15 Plano TX 75074 US 2513 BH The Hague Tel 800 763 6901 Netherlands Outside US 1 972 889 8857 Tel 31 0 70 345 8570 www dentlight com C lt Fax 31 0 70 346 7299 1 2015 v2 4
4. Liquid water rain extreme humidity ultrasonic autoclaving Tampering improper repairs or modifications that have not been carried out by a certified Service Center Use of other spare parts and accessories other than from the manufacturer such as incorrect power adapter Other acts which are not the faults of DentLight For service call 1 800 763 6901 in US to obtain RMA number Fill out RMA form online and return as instructed In case of a warranty claim the complete apparatus must be returned Alternatively contact your dealer for service return Troubleshooting Guide Error Indication Possible Solutions Light will not 1 No Battery Bar or no battery 1 Charge Battery Pack overnight turn on power indicating beep 2 Bad connection between the lamp and the 2 Battery full but beeps when lamp battery Replace battery or lamp or have it sent is connected back for service 3 Wire connector broken 3 Replace wire or return to manufacturer for component service Battery will not 1 Broken pins in battery DC plug Replace battery pack or return to manufacturer charge 2 Battery out of capacity for service Reorder and Optional Item Codes REF Description REF Description 8600112 8500021 8600020 Nano Headlamp 8500223 Soft Headband 8600130 Nano 2S Battery Pack 8500040Y Power Adapter 8600230 Nano 2C Battery Pack 8501012 xY US EU UK AU Australia DentLight Inc id Emergo Group EMERG EUROP
5. NentLight rr Setting New Standards through Innovation NANO INSTRUCTIONS FOR USE Nano Loupe Light Rev 2S and 2C Powered by Patent pending Optics and Teflon Nano Wire Technology Product Information Description and Indications for Use Nano Loupe Light is engineered to meet the demand for the smallest and toughest professional portable light requiring a small homogenous and well defined spot in the dental office physician s office hospital or emergency environment for any medical procedures These operating instructions provide recommendations and guidelines for the intended use of the light Please read them carefully System Components Nano Loupe Light consists of Nano Headlamp with durable nano engineered wire Composite F ilter Composite Filter Flip Paddle Wire Wrap Clip Wire Shirt Clip a Loupe E yewear Mounting Adapter Rechargeable Battery Pack Battery Clip Pouch Lamp Wire Protection Cord Power Adapter and Instructions for Use No Quantity Description One compatible mounting adapter per kit of user s choice Default kit if not specified is Universal Clip on 2S or 2C battery 2S Clip or 2C Pouch jn m a a D poi a EE DentLight et Product Safety Warnings and Cautions Prior to installation and activation of the light please read these instructions carefully and follow safety procedures as well as the specific safety comments and recommendations presented throughout the instruction
6. eceiving your Nano light remove all components from the package and examine them If damage is apparent please contact your authorized DentLight distributor Mountin from whom your light was purchased Composite Wi Screw g Ww Nano Lm Wire 4 Mounting Filter Cross reference your loupes glass frame for the corresponding adapter For TTL loupes take out custom fixture logo plate at the center of the frame Assemble light using the loupe mounting adapter that Articulating you purchased with the light kit Hea dain Arm a L Adapter Heat Sink Place L adapter at the center of the frame Screw on Mounting Screw s directly or with the provided Mounting Plate Nut s using a Philips screw driver Tighten the mounting screw s Adjust the light to the most comfortable position to ensure that the Nano Headlamp is positioned at a distance away from the nose pad Direct the light to the center of your field of vision Route the Wire by bending in an angle to conform to the frame 1 Orascoptic Rudy frame 2 Orascoptic Titanium frame 3 Zeiss EyeMag Pro 4 Orange Adidas 5 Surgitel metal frame 6 Sheervision TTL b Universal Clip on Adapter Universal Clip on Adapter can be used on any frames with a relatively flat center bridge including most of the meta titanium frames prescription and safety glasses Press thumb and index finger on the top front and back flanges to open the spring loaded Clip on Slide into frame cent
7. ening the tip do not soak with Isopropyl alcohol Machine wash Soft Headband Product Specification Type of information won eooo 5000 6500 Light Intensity Level l 16000 150 x ONY Il veer 20000 Power Adapter Input 100 240V 50 60Hz Output 5V DC 2A Beam Size inch 2 8 14 inch distance hours Battery Lithium lon 2S and Lithium Polymer 2C Recharging time 3 hrs LED indicator on during charging and off when fully charged Lamp Dimension mm 18 diameter Life time of the device is two years in normal office use based on the life of the battery Replace the battery for continued use after that IEC 60601 1 2 45x76x15 2C 46x74x21mm 2S Weight grams Lamp 6 Battery 85 2C 140 2S Limited Life time WARRANTY Register your Nano light at www dentlight com DentLight Inc extends a Life time warranty on the LED bulb and one year warranty on the rest of the components including battery lamp and protection cord against defects in material and workmanship to the original purchaser of this product This warranty is valid providing factory inspection indicates that any such defect was developed during normal and proper use DentLight shall under no circumstances be liable for incidental special consequential damages and damage from misuse including the following expressed or implied Improper operation accident or neglect misuse or abuse such as physical damage drops cuts scratches etc
8. er then release for secure grip on the frame 90 degrees Frame Temple Route and bend the lamp wire to conform to the frame Use Wire Wrap Wire Wrap clip to secure the lamp wire on the Frame Temple DFV Designer Titanium Frame c U Adapter for Flip up Loupes U adapter is suitable for most flip up loupes on the market as listed below Slide in the U Adapter to the middle of the flip up bar Adapter Brand Model Frame Orascoptic Any frame LEGACY Surgitlel FLM Anyframe LEGACY PANORAMIC PeriOptix Any frame Biema Rose Micro Any frame Flipup Sheervision FLIP UP Any frame Keeler Flipup d Y Adapter Y adapter mounts to curved frames with center bridge thickness from 4 to 10 mm It comes with the corresponding number of Articulating Arms to fit onto your custom loupes OPEN THE VARIABLE CENTER SPACING enough to slide into the frame center bridge from a direction as shown in the illustration below Tighten adjustment screw for secure mount Adapter Brandname Model Frame Skylon Skyview Sports Nike 2 Half Jacket Radar Oakley Y DEV Yoeman Aluminum Pounce Revolve Nike Sheervision Under Armour Plastic Sheervision Del Rey Plastic Surgitel Oakley DFV Yoeman DFV Nike Mounting Summary The light mounting instructions above provides general e o Te guidance to light assembly steps Consult with DentLight for detailed instructions on custom loupe assembly and loupe adapters
9. s for use The manufacturer accepts no liability for any damage resulting from the improper use of this unit and or for any purpose other than those covered by these instructions L A CAUTION Heat sink metal ring end of Nano Headlamp will be hot when in use for extended period of time at Level Ill Do not touch with bare skin 2 A CAUTION Do not look directly at light emitted from the device Eye injury may result 3 Do not touch and open any electronics parts and circuit boards Warranty void if seal broken 4 Do not immerse Nano Headlamp in waters or solutions Warranty void in case of liquid damage 5 Charge batteries while not in use to extend the lifetime of the rechargeable battery a Do not short circuit battery b Donotstore above 60 C 140 F c Dispose of unserviceable batteries according to the national rules and regulations Batteries must not be incinerated Glossary of Symbols A number of symbols are used on the device accessories and throughout this manual it is important that the user operator of Nano understands the meaning of each symbol to avoid possible injury to the operator or and patient LE Please read before using this device Symbol is used to alert you to potential personal injuries and hazard Waste Electrical and Electronics Equipment WEEE Attention consult accompanying documents E European Authorized Representative es e C SN SerialNumber REF Product Number Start Up Upon r
Download Pdf Manuals
Related Search
Related Contents
Opus 600 - Beyerdynamic Copyright © All rights reserved.