Home

Keysight Technologies 34401A Digital Multimeter

image

Contents

1. Keysight Technologies Inc DEKRA Certified ISO 9001 2008 Quality Management System Keysight Channel Partners www keysight com find channelpartners Get the best of both worlds Keysight s measurement expertise and product breadth combined with channel partner convenience www keysight com find 34401A KEYSIGHT TECHNOLOGIES open standard that extends the AdvancedTCA for general purpose and semiconductor test Keysight is a founding member of the AXle consortium ATCA AdvancedTCA and the ATCA logo are registered US trademarks of For more information on Keysight Technologies products applications or services please contact your local Keysight office The complete list is available at www keysight com find contactus Americas Canada 877 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States 800 829 4444 Asia Pacific Australia 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 800 11 2626 Japan 0120 421 345 Korea 080 769 0800 Malaysia 800 888 848 Singapore 800 375 8100 Taiwan 0800 047 866 Other AP Countries 65 6375 8100 Europe amp Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 reland 1800 832700 srael 1 809 343051 taly 800 599100 Luxembourg 32 800 58580 etherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt 1 DE Opt 2 FR Opt 3 IT Unit
2. 0 0004 0 0020 0 0005 0 0035 0 0005 0 0005 0 0001 100 0000 V 0 0020 0 0006 0 0035 0 0006 0 0045 0 0006 0 0005 0 0001 1000 000 V 0 0020 0 0006 0 0035 0 0010 0 0045 0 0010 0 0005 0 0001 3 5 Hz 1 00 0 03 1 00 0 04 1 00 0 04 0 100 0 004 5 10 Hz 0 35 0 03 0 35 0 04 0 35 0 04 0 035 0 004 100 0000 mV 0 Hz 20 kHz 0 04 0 03 0 05 0 04 0 06 0 04 0 005 0 004 20 50 kHz 0 10 0 05 0 11 0 05 0 12 0 05 0 011 0 005 50 100 kHz 0 55 0 08 0 60 0 08 0 60 0 08 0 060 0 008 eae 00 300 kHz 4 00 0 50 4 00 0 50 4 00 0 50 0 20 0 02 mie 3 5 Hz 1 00 0 02 1 00 0 03 00 0 03 0 100 0 003 5 10 Hz 0 35 0 02 0 35 0 03 0 35 0 03 0 035 0 003 1 000000 V to 0 Hz 20 kHz 0 04 0 02 0 05 0 03 0 06 0 03 0 005 0 003 750 000 V 20 50 kHz 0 10 0 04 0 11 0 05 0 12 0 04 0 011 0 005 50 100 kHz 0 55 0 08 0 60 0 08 0 60 0 08 0 060 0 008 00 300 kHz 4 00 0 50 4 00 0 50 4 00 0 50 0 20 0 02 00 0000 Q mA current source 0 0030 0 0030 0 008 0 004 0 010 0 004 0 0006 0 0005 000000 kQ mA 0 0020 0 0005 0 008 0 001 0 010 0 001 0 0006 0 000 0 00000 KQ 00 pA 0 0020 0 0005 0 008 0 001 0 010 0 001 0 0006 0 000 Resistance 100 0000 KQ O uA 0 0020 0 0005 0 008 0 001 0 010 0 001 0 0006 0 000 000000 MQ 5 0 uA 0 002 0 001 0 008 0 001 0 010 0 001 0 0010 0 0002 0 00000 MQ 500 nA 0 015 0 001 0 020 0 001 0 040 0 001 0 0030 0 0004 00 0000 MQ 500
3. nA II 10 MQ 0 300 0 010 0 800 0 001 0 800 0 001 0 1500 0 0002 0 00000 mA lt 0 1 V burden voltage 0 005 0 010 0 030 0 020 0 050 0 020 0 0020 0 0020 C current 00 0000 mA lt 0 6 V 0 010 0 010 0 030 0 005 0 050 0 005 0 0020 0 0005 000000 A lt 1 0V 0 050 0 010 0 080 0 010 0 100 0 010 0 0050 0 0010 3 00000 A lt 2 0V 0 100 0 010 0 120 0 020 0 120 0 020 0 005 0 0020 3 5 Hz 1 00 0 04 1 00 0 04 1 00 0 04 0 100 0 006 000000 A 5 10 Hz 0 30 0 04 0 30 0 04 0 30 0 04 0 035 0 006 True rms 0 Hz 5 kHz 0 10 0 04 0 10 0 04 0 10 0 04 0 015 0 006 AC current 3 5Hz 1 10 0 06 1 10 0 06 1 10 0 06 0 100 0 006 3 00000 A 5 10 Hz 0 35 0 06 0 35 0 06 0 35 0 06 0 035 0 006 0 Hz 5 kHz 0 15 0 06 0 15 0 06 0 15 0 06 0 015 0 006 3 5 Hz 0 10 0 10 0 10 0 005 Frequency 10 Hz 0 05 0 05 0 05 0 005 or period 1OOMVto 750V tg _ pou 0 03 0 03 0 03 0 001 40 Hz 300 kHz 0 006 0 01 0 0 0 001 Continuity 000 0 Q mA test current 0 002 0 030 0 008 0 030 0 010 0 030 0 001 0 002 Diode test 0000 V mA test current 0 002 0 010 0 008 0 020 0 010 0 020 0 001 0 002 1 Specifications are for 1 hr warm up and 6 digits slow ac filter 2 Relative to calibration standards 3 20 over range on all ranges except 1000 Vdc and 750 Vac ranges 4 For sinewave input gt 5 of range For inputs from 1 to 5 of range and lt 50 kHz add 0 1 of range additional error 5 750 V range limite
4. 60 dB lt 1 plc 3 ms or 800 us 0 dB Operating characteristics Function Digits Reading s dcV del and resistance 6 0 6 0 5 6 6 5 5 60 50 5 300 4 000 acV acl 6 0 15 slow 3 Hz 6 medium 20 Hz 6 0 fast 200 Hz 5 6 50 Frequency or period 6 5 9 8 4h 80 GP Ol Ae OO S For 1 kQ unbalanced in LO lead 500 V peak maximum For power line frequency 0 1 For power line frequency 1 use 40 dB or 3 use 30 dB Reading speeds for 60 Hz and 50 Hz operation Maximum useful limit with default settling delays defeated Speeds are for 4 2 digits delay 0 auto zero and display OFF 05 Keysight 34401A Digital Multimeter Data Sheet Measurement Characteristics continued System speeds Configuration rates 26 s to 50 s Autorange rate dc Volts gt 30 s ASCII readings to RS 232 55 s ASCII readings to GPIB 1000 s Maximum internal trig rate 1000 s Max ext trig rate to mem 1000 s Triggering and memory Reading HOLD sensitivity 10 1 0 1 or 0 01 of range Samples trigger 1 to 50 000 Trigger delay 0 to 3600 s 10 us step size External trigger delay lt 1 ms External trigger jitter lt 500 us Memory 512 readings Math functions NULL min max average dBm dB limit test with TTL output Standard programming languages SCPI IEEE 488 2 Keysight 3478A Fluke 8840A 42A Accessories included Test lead kit with probe all
5. Keysight Technologies 34401A Digital Multimeter Math Lo jar gt E dem Come n Nutt j j KEYSIGHT TECHNOLOGIES Data Sheet Product Discontinuance Notice The 34401A DMM and all associated options will be discontinued December 1 2016 The last date this product can be ordered is November 30 2016 For new product purchases Keysight recom mends the 34461A 6 digit Truevolt DMM For more information as well as to access to detailed migration guides please visit www keysight com find nextgenDMMs To contact a product selection expert visit www keysight com find contactus 02 Keysight 34401A Digital Multimeter Data Sheet Measurement capability 6 digit resolution 10 measurement functions DC AC voltage DC AC current 2 and 4 wire resistance diode continuity frequency period Basic accuracy 0 0035 DC 0 06 AC 1000 V max voltage input 3 A max current input System Capability 1000 readings second 512 reading memory www keysight com find dmm Superior performance The Keysight Technologies Inc 34401A multimeter gives you the performance you need for fast accurate bench and system testing The 34401A provides a combination of resolution accu racy and speed that rivals DMMs costing many times more 6 digits of resolution 0 0015 basic 24 hr dcV accuracy and 1 000 readings s direct to GPIB assure you of results that are accurate fast a
6. d to 100 kHz or 8 x 107 Volt Hz 6 Typically 30 of reading error at 1 MHz 7 Specifications are for 4 wire ohms function or 2 wire ohms using Math Null Without Math Null add 0 2 Q additional error in 2 wire ohms function 8 Input gt 100 mV For 10 to 100 mV inputs multiply of reading error x 10 9 Accuracy specifications are for the voltage measured at the input terminals only 1 mA test current is typical Variation in the current source will create some variation in the voltage drop across a diode junction 88 5 od og000000 eo mm eooo0 0e NA k 348 3 mm gt 04 Keysight 34401A Digital Multimeter Data Sheet Measurement Characteristics DC voltage Measurement method Continuously integrating multi slope IIl A D converter A D linearity 0 0002 of reading 0 0001 of range Input resistance 10 MQ or 0 1V 1 V 10 V ranges 100 V 1000 V ranges Input bias current Selectable gt 10 000 MQ 10 MQ 1 lt 30 pA at 25 C Input protection 1000 V all ranges dcV deV ratio accuracy V accuracy V put in accuracy relevance True RMS AC voltage Measurement method AC coupled true rms measures the ac component of the input with up to 400 Vdc of bias on any range Crest factor Additional crest factor errors non sinewave aximum of 5 1 at full scale rest factor 1 2 0 05 of reading C Crest factor 2 3 0 15 of reading Crest facto
7. ed Kingdom 0800 0260637 For other unlisted countries www keysight com find contactus BP 04 23 15 This information is subject to change without notice Keysight Technologies 2013 2015 Published in USA May 21 2015 5968 0162EN www keysight com
8. igator and grabber attachments Operating manual service manual test report and power cord General specifications Power supply 45 to 66 Hz and 360 to 440 Hz Power line frequency 100 V 120 V 220 V 240 V 10 automatically sensed at power on Power consumption 25 VA peak 10 W average Operating environment Full accuracy for 0 to 55 C full accuracy to 80 R H at 40 C Storage temperature 40 to 70 C Weight 3 6 kg 8 0 lbs Safety Designed to CSA UL 1244 IEC 348 RFI and ESD MIL 461C FTZ 1046 FCC Ordering Information Keysight 34401A multimeter accessories included Test lead kit with probe alligator and grabber attachments calibration certificate test report and power cord Also includes CD with IntuiLink software IVI and VXI PnP drivers Quick start tutorial user s guide command quick reference service guide and data sheet Options 34401A A6J ANSI Z540 compliant calibration Accessories Probes Leads Clip Accessories 11059A Kelvin probe set 11060A Surface mount device SMD test probes 11062A Kelvin clip set 34133A Precision electronic test leads 34134A DC coupled current probe 34136A High voltage probe 34138A Test lead set 34171B nput terminal connector sold in pairs 34172B nput calibration short sold in pairs 34330A 30 A current shunt E2308A 5 k thermistor probe Y1133A Low thermal external digita
9. l multimeter scanning kit Rackmount kits 34190A Rackmount kit Designed for use with only one instrument mounted on either the left or the right side of he rack 34191A 2U Dual flange Secures the instrument to the front of the rack kit This kit can be used with the 34194A dual lock ink kit to mount two half width 2U height instruments side by side 34194A Dual lock link Recommended for side by side combinations kit and includes links for instruments of different depths This kit can be used with the 34191A a 2U dual flange kit to mount two half width 2U height instruments side by side Vibration and shock MIL T 28800E Type III Class 5 sine only Warranty 1 year Other accessories 34131A Hard transit case 34161A Accessory pouch 34398A RS 232 cable 9 pin f to 9 pin f E5810B LAN GPIB gateway 06 Keysight myKeysight AXie LI DEKRA befiified 34401A Digital Multimeter Data Sheet myKeysight www keysight com find mykeysight A personalized view into the information most relevant to you www axiestandard org AdvancedTCA Extensions for Instrumentation and Test AXle is an the PCI Industrial Computer Manufacturers Group www lxistandard org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems Keysight is a founding member of the LXI consortium www keysight com go quality
10. nd repeatable Use it on your benchtop The 34401A was designed with your bench needs in mind Func tions commonly associated with bench operation like continuity and diode test are built in A Null feature allows you to remove lead resistance and other fixed offsets in your measurements Other capabilities like min max avg readouts and direct dB and dBm measurements make checkout with the 34401A faster and easier The 34401A gives you the ability to store up to 512 readings in internal memory For troubleshooting a reading hold feature lets you concentrate on placing your test leads without having to constantly glance at the display Mie AN kevsichT 2440 Use it for systems testing For systems use the 34401A gives you faster bus throughput than any other DMM in its class The 34401A can send up to 1 000 readings s directly across GPIB in user friendly ASCII format You also get both GPIB and RS 232 interfaces as standard features Voltmeter Complete and External Trigger signals are provided so you can synchronize to other instruments in your test system In addition a TTL output indicates Pass Fail results when limit testing is used To ensure both forward and backward compatibility the 34401A includes three command languages SCPI Keysight 3478A and Fluke8840A 42A so you don t have to rewrite your existing test software An optional rack mount kit is available Easy to use Commonly accessed attributes s
11. r 3 4 0 30 of reading Crest factor 4 5 0 40 of reading Input impedance 1 MO 2 in parallel with 100 pF Input protection 750 Vrms all ranges Resistance Measurement method Selectable 4 wire or 2 wire Ohms Current source referenced to LO input Maximum lead resistance 4 wire 10 of range per lead for 100 Q 1 kQ ranges 1 KQ per lead on all other ranges Input protection 1000 V all ranges DC current Shunt resistance 50 for 10 mA 100 mA 0 1 QO for1A 3A Input protection Externally accessible 3 A 250 V fuse Internal 7 A 250 V fuse True RMS AC current Measurement method Directly coupled to the fuse and shunt ac coupled true rms measurement measures he ac component only Shunt resistance 0 1 Q for1 Aand 3A ranges Input protection Externally accessible 3 A 250 V fuse nternal 7 A 250 V fuse Frequency and period Measurement method Reciprocal counting technique Voltage ranges Same as ac voltage function Gate time 1s 100 ms or 10 ms Continuity diode Response time 300 samples s with audible tone Continuity threshold Selectable from 1 Q to 1000 Q Measurement noise rejection 60 50 Hz dc CMRR 140 dB ac CMRR 70 dB Integration time and normal mode rejection 100 plc 1 67 s 2 s 60 dB 0 plc 167 ms 200 ms 60 dB 1 plc 16 7 ms 20 ms
12. uch as functions ranges and resolution are selected with a single button press Advanced features are available using menu functions that let you optimize the 34401A for your applications The included Keysight IntuiLink software allows you to put your captured data to work easily using PC applications such as Microsoft Excel or Word to analyze interpret display print and document the data you get from the 34401A You can specify the meter setup and take a single reading or log data to the Excel spreadsheet in specified time intervals Programmers can use ActiveX components to control the DMM using SCPI commands To find out more about IntuiLink visit www keysight com find intuilink 3 year warranty With your 34401A you get full documentation a high quality test lead set calibration certificate with test data and a 3 year warranty all for one low price 03 Keysight 34401A Digital Multimeter Data Sheet Accuracy Specifications of reading of range Temperature coefficient 24 hour 90 day 1 year 0 18 C Function Range Frequency etc 75 a 1G 23 5 C 23 5 C 28 55 C 100 0000 mV 0 0030 0 0030 0 0040 0 0035 0 0050 0 0035 0 0005 0 0005 1 000000 V 0 0020 0 0006 0 0030 0 0007 0 0040 0 0007 0 0005 0 0001 DC voltage 10 00000 V 0 0015