1. in a 3 phase transformer is magnetic circulation that occurs in a figure 8 pattern between coils A B and C Many people attempt to convert surpus 3 phase welders to single phase power by connecting some or all coils of the welding transformer to be powered by a single phase line While this frequently results in a certain amount of operational Capacity it is usually very limited either output current or voltage and poor arc stability The reason for poor and limited performance is because the 3 phase transformer is designed in such a way that magnetic circulation occurs in a figure 8 through each coil in sequence but when using the common methods the sequence doesn t exist so the transformer s magnetic strength is crippled by eddy currents The Haas Kamp conversion method utilizes a wiring technique that does precisely that by connecting the two outer coils of the transformer 180 degrees out of phase and driving the MIDDLE coil 90 degrees out of phase the magnetic flow sequence circulates through the transformer core as was originally designed Once the sequence has been established the cores are able to generate output and as a result the welding supply s output is same as if it were running on genuine three phase power W Coils A and C are 180 C E degrees out of phase y mmm Alternations at L1 and L2 cause magnetic alterations around
2. the perimeter of the core B y E Be NON L YN c NNI L2 L1 Current to Coil B being driven through A L2 L1 capacitors is phase shifted by 90 degrees While A and C are reversing B is inducing a crossing current forcing circulation through the center of the core This phase shift works in all four quadrants of the AC cycle between alterations of the A and C coils hence the transformer core s magnetic sequence is retained E E b EC C E B B L2 L1 A L2 L1 Basic Procedure The basic procedure for any Haas Kamp conversion is simple O Isolate the individual coils of the main power transformer Second is to isolate any other segments additional single phase loads like fan control transformers and other devices O Configure the main transformer so that windings can be fed 240v single phase power and next is to wire the two outer primaries A and C to incoming 240v but wire the C phase BACKWARDS in relation to A phase O Connect the B phase center coil to incoming mains through capacitors to provide 90 degrees of phase shift at the welder s Full Load Amps rating O Configure and connect all ancillary devices cooling fans control transformers etc to the single phase line connection points
3. to Y couldn t be much easier the commensurate boost in output voltage brings it right back to where output SHOULD be and testing indicates output current and duty cycle are not hindered by the change var f if i O ce DODUUDL UgUUL JOUL JUUUL t POUN P JUL SEL HY eJ TU shorting bar T ae 57 ES Dt ik l DEJE E ME i EE y NEG POSITIVE LOW sragnazkeR HIGH GAINING ACCESS Converting the CP 200 The Miller CP 200 s electrical connections occur in two basic locations first is on the main terminal strip TE1 and the second is on the top terminals of the welding output contactor This requires gaining access to the welder s internals removing existing connections and making proper new connections followed by mounting new componentry testing and reassembly Remove any hardware necessary to remove top and side covers from the welder It will be necessary to remove wire feeders or other equipment attached to the top or sides Your Miller CP 200 operations and service manual identifies how to remove covers to reach this panel recommend removing both sides and top cover as it makes working on the machine much easier PREPARE TERMINAL STRIP 1 Find the top terminal of main terminal strip 2 With a permanent marker mark this terminal as amp 1 and continue downward There will be three groups of four terminals so 1 4 5 8 9 12 3 On the right s
4. O Make any alterations necessary to make proper welder control and if necessary adaptations to put the welding transformer output in proper realm for operation in the CP 200 this means changing secondary side from Delta to Y configuration CP 200 challenges The CP 200 presents some interesting twists first being that the CP 200 started on is a 480 240v machine but the primary windings are connected in Y configuration there s six coil windings two on each phase When voltage selection jumpers are set to 240v each coil is wired in parallel and when jumpers are in 480v all coils are in series With the y centerpoint in place that means that each LEG of the Y is actually a 277v winding when in series and 138 5v when in parallel TEJ a _ 2 i r i Lo i a jr pw ae PE E J mmm mm r O LO ss Ea L a d L2 L LATE GAD 951 PE 0000 Lago 000 0000 2000 10000 B D NEGO POSITIVE LOW araniiizen HIGH Circuit Diagram No C4 901 857 14 This conversion entails disconnecting the centerpoint and treating each phase like a 240v load which means we re only driving the 277v coil to a portion 240v of it s design voltage We re down by 14 That means that when our indicated output voltage on machine s front panel indicates 17v we should only see 14 7 and at 28v we ll only see 24 2v This is a pretty big drop Fortunately the CP 200 s OUTPUT is configured as delta and converting it
5. STEP BY STEP MLLER CP 200 Haas Kamp Single Phase Conversion Applicability The following procedure identifies step by step conversion process for the Miller CP 200 constant voltage welding power supply series manufactured in the vicinity of 1973 It MAY be applicable to other years however there are several variations of the CP 200 supply It is necessary for you to research YOUR model and year to verify that wiring connections indicated here MATCH your welding supply s vintage On the front of every MILLER CP 200 is the model number AND serial number Miller s website has a lookup function in the RESOURCES tab attempt to do a document search for your serial number If none is found send your serial number to Miller s site support they will Email you a copy of the original manual in PDF format They are truely wonderful people Read through the entire process and compare each indicated step and corresponding drawing indication with your welder s wiring diagram AND internal connections If at ANY point you find that your connections are not identical to those indicated here do NOT use this procedure About the Haas Kamp conversion The Haas Kamp method utilizes a simple process for fully powering a 3 phase welding transformer with single phase power In a properly powered 3 phase transformer the incoming power s 3 phase sequence occurs at 120 degree intervals 360 divided by 3 120 degrees The operating result
6. by flattening a piece of 3 4 copper pipe bending and drilling to fit Some contactor terminals are in same plane this one happens to have center pole higher than the others so I had to do some bending to make it fit MAKE NEW POWER CONNECTIONS 1 Using 3 8 nutdriver loosen all terminal strip nuts and remove all jumpers 2 Remove nuts from terminals 1 4 5 8 9 and 12 3 Install blue 10awg wire on terminal 5 4 Install blue 10awg wire on terminal 8 5 Install jumper from terminal 6 to 7 6 Install red 10awg wire from terminal 9 to terminal 4 7 Install another red 10awg wire 24 long on terminal 4 lay it down near capacitors 8 Apply red tape to wire 9 Trim and apply ring lug and connect to terminal 4 along with fan power wire 20 and install nut 9 Install black 10awg wire from terminal 12 to terminal 1 10 install another black 10awg wire 24 long on terminal 2 lay it down near capacitors 11 1 2 13 Verify all connections double check torque on all terminal strips Apply ring lug to wire 10 and connect to terminal 1 along with fan power wire 40 and install nut Install jumper from terminal 10 to 11 Terminal strips are brass do not overtighten as they will break L TE um Lp Ly O E tr Lr a Jap E a ay E i Tenta nm oe Pat ee pi H E F ira lE Es VU ep ade MOUNT AND CONNECT CAPACITORS Mounting capacitors is entirely dependant upo
7. d or become contaminated at which time the contacts will increase in resistance thus getting hot during welding The contact surfaces can melt off as illustrated here If you look on previous pages you ll see that this one contact appeared discolored It is probably the reason why the welder was taken out of service noticed the discoloration but decided to continue and check it out once this was all done Contacts for the stock FURNAS brand contactor are probably available through Miller Replacing the contactor with a standard type is also a viable option This application requires about 7kw of capacity up to 50v and around 75A per terminal under intermittant duty Coil operates on 120vac Broken wires to one of the transformer windings This commonly occurs as a result of working on the terminal strip Copper wires going to the transformer primary are solid and can be rather brittle Failure mode here is a welder that works fine for a little while then intermittantly becomes weak but will return at full strength after cooling off Best way to find broken wires on these is to disconnect all power then reach behind the panel and push on each connecting wire to see if it s broken from it s terminal Correct broken wires by crimping and soldering on a new terminal to the wire but scrub the wires clean first as they re coated with insulating varnish
8. ide of main terminal strip are three large power terminals Label these A B and C starting from TOP 4 Remove nut and ground lug from bottom terminal strip bolt then bottom and top terminal strip retainer bolts 5 Gently pull terminal strip away about an inch so that connections on rear of terminal strip are visible wo gd rk ed Tiga eg ee eed ed ee bho e eee a a sa Geer TOS LEE ee ere r to F prr Sm mad Rm pm TEN E erica C NOS arab je Use pei pa p p Lb do Due B DOEEUM ees Fd dress i im ac nre md eas rm za cha mdi wg 5 ES BPS PE BA DE Maree hls ped inda ge ers ee nnl see to hd ee eer za 200 208 VOLTS e He da th o 3230 VOLTS NV NU ui 130 VOUS ra ee mia amp a Da Bs 60 veo Figure 1 3 5 rgan Wehea Jure Lig Area WEG PRE Und cns Tr curta Wan hs d nami ee es thon unn ot cg camur T perd edis bea mg dem drin cuneum alti F barr m cumwhs un oang m nus arman rusy scum mo a fr ae midi ku DER ou eua lag Wa Hep ma mollem A Boss Des go i erro an aed cee es er j d maium Tee amid cwm ee giga AMATEAS LOM Abs HLH aad POG V aem annr rul nos re pant ac el dua ivan pam d mara pusim n n fo aoe dcc Gh peg a Eom Ei deu Cube Pa Pm PS coed rer mumal ami chan vee oe de gea chm BEYIRTIWE Eug ETAF FH ub chee eters Deed Fer rimimi mii om chm im wi RPA TT manm armas E eee ca es ace IU S O a il D E Tamia J r Fisting Orbis ima m Cee HP h
9. n the size and shape of capacitors found The Miller CP 200 requires oil filled MOTOR RUN type capacitors of 60 microfarad uF with voltage rating of at least 370vac Do NOT use MOTOR START capacitors or capacitors not rated for continuous duty AC and do NOT go below 370v Any voltage above 370 is fine 450v is recommended Mount capacitors in any convenient and safe location within the cabinet You will likely need to fabricate appropriate brackets to secure capacitors Keep in mind that the welder is inherently a dirty and vibration prone environment Solder 15k 5 watt resistor across terminals of each capacitor Connect 10AWG RED wire from terminal 4 to ONE lug of one capacitor Connect 10AWG BLUE wire from terminal 8 to OTHER lug of capacitor Connect 10AWG BLACK wire from terminal 1 to one lug of OTHER capacitor Connect 10AWG BLUE wire from terminal 5 to OTHER lug of capacitor PES Hay tel EU qa AA E i Connect incoming power cord BLACK to terminal A Connect incoming power cord RED to terminal B Connect incoming power cord WHITE if exists to terminal C This connection is only to prevent a white wire from hanging loose inside the cabinet Neutral is NOT used in this conversion Connect incoming power cord GREEN to remaining lug and bolt to terminal strip mounting lower mounting stud REASSEMBLY Reassembly of the welder is opposite of disassembly Make certain tha
10. rm bP S9g PITT Cod Ds Fas F REMOVE EXISTING CONNECTIONS 1 Cut jumper wire connecting terminal 1 to terminal 5 2 Cut jumper wire connecting terminal 5 to terminal 9 3 Cut fan power wire 40 connected to terminal 7 You ll have to pull the terminal strip out a little and follow it down from the zip tie d point up top 4 Cut fan power wire 20 connected to terminal 11 Again follow these from the fan wiring zip tied up at the top 5 Cut wire 8 connected at terminal 12 This is done from the right side of the terminal strip 6 Cut wire 9 connected at terminal 8 This is done from the right side of the terminal strip 7 Cut wire 10 connected at terminal 4 This is on the left side of the terminal strip 8 Follow wire 8 to where it meets front panel control switch Cut and remove Wire 8 9 Check all wire cut locations to make sure that no fragments of cut wire are exposed in such a way that they ll contact any other terminals or the chassis 10 Reinstall terminal strip Exercise care when installing terminal strip wires from coils are solid core and tend to be brittle If pulled too much they will break causing malfunction and possible short circuits CONVERT SECONDARY FROM DELTA TO WYE Disconnect and tape three large wires from upper terminals of power contactor Apply jumper bar across three upper terminals of power contactor NOTE Jumper bar can easily be made
11. t O Terminal strip TE1 is fully seated on mounting studs O Hardware holding terminal strip is secure and properly torqued O All power wiring is secured as fan vibration will loosen connections O Sliding brushes move freely without snagging wiring O Metal covers won t pinch and short wires Install all fasteners in proper locations some are self tapping while some may be machine screws Install all fasteners prior to tightening any so that you can make adjustments to front and rear panel positions Reinstall wire feeder and other accessories CORRECT ALL LABELS lt is very important that the unit be appropriately re labeled to indicate it s new power input use a permanent marker and identify 240v SINGLE PHASE at the cord exit point AND on the front panel legend also include a laminated copy of the new wiring diagram just in case the unit is ever opened for service or repairs TEST Power up and test the unit to verify that operation is all proper and that power output is within expected range Open Circuit Voltage indicated on meter will likely be a little different from that indicated on adjustment scale which is to be expected These welders coils were originally designed for 277v across each leg and in this circumstance they re getting 240v which is only 86 of original This results in a corresponding drop of 86 in the output The original output configuration was DELTA which yields a calculated outp
12. ut of 19 9v By changing the output to wye the indicated open circuit voltage jumps to 34 4 Under a stable arc condition expect to see it running at O Ata minimum scale indication of 19v measured 21v O Ata scale indication of 20v measured 23v O Ata maximum scale indication of 50v measured 51v O In operation observe 26v open circuit and 17v at 150A with feedrate of 270ipm running 0 035 ER 70S wire POSSIBLE SUSPECTS If your welding supply isn t operating properly check the following O Dirty contact surfaces in the voltage selection brushes O Poor contact at the main contactor Broken wires to one of the transformer windings Dirty contact surfaces in the voltage selection brushes Voltage selection for the CP 200 is by a moving brush arrangement across the welding transformer s secondary As shown in these photos the surfaces are subject to corrosion from air exposure as well as erosion from use A good scrubbing with an abrasive scrubbing pad i e Scotchbrite or similar makes them shiny and clean Access will require you to crank the control to full max scrub one side then full minimum to clean the other Make sure the brushes are moving freely while you re in there Poor contact at the main contactor The main welding contactor carries current only when the gun trigger is pulled These contactors are subjected to wear based on usage but also corrode a bit during disuse Over time they ll erode an