1. n oo onn n Second Backwash is optional Table 2 below shows the order of the cycles when the valve is set up as a filter If the control valve is set to regenerate for a filter it allows the option of having the regenerant refill after the rinse cycle or have the regenerant prefill before regeneration If chosen to have the regenerant prefill before regeneration the prefill starts two hours before the regeneration time set During the 2 hour period in which the regenerant is being made treated water is still available For example regeneration time 2 00am prefill option selected downflow filter Fill occurs at 12 00am start of backwash cycle occurs at 2 00am Tables 5 and 6 Page 5 show the length of the cycles when different program codes are selected When the control valve is used as a non regenerating filter backwash only it allows the option to specify one backwash or two backwashes If two backwashes are specified two rinses occur Tables 5 and 6 Page 5 show the length of the cycles when the valve is set up as a filter When used as a non regenerating filter the downflow piston must be installed the regenerant piston removed injector plugs must be installed in both the DN and UP injector locations and the refill eloow must be replaced with a refill port plug Table 2 Regeneration Cycles for Filtering See NOTE on page 3 WS1CS amp WS1 25CS Downflow WS1CS amp WS1 25CS Downflow
2. STEP 3 IS Day Override When Gallons Capacity is set to OFF sets the number of days between regenerations When gallon capacity is set to AUTO or to a number sets the maximum number of days between regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a number allowable range from 1 to 28 a regeneration initiation will be called for on that day even if sufficient number of gallons were not used to call for a regeneration Set Day Override using V or A buttons number of days between regeneration 1 to 28 or See Table 8 Setting Options Page 8 for more detail on setup Press NEXT to go to Step 4 IS Press REGEN to return to previous step STEP 4 IS Next Regeneration Time Hour Set the hour of day for regeneration using or A buttons AM PM toggles after 12 The default time is 2 00am This display will show REGEN on 0 GAL if on 0 is selected in Step 8 SS Page 9 or Step 7 FS Page 10 Press NEXT to go to Step 5 IS Press REGEN to return to previous step STEP 5 IS Next Regeneration Time Minutes Set the minutes of day for regeneration using W or A buttons This display will not be shown if on 0 is selected in Step 8 SS Page 9 or Step 7 FS Page 10 Press NEXT to exit Installer Displays amp Settings Press REGEN to return to previous step To initiate a manual regeneration immediately press and hold
3. 1 5 inch e 1 25 inch Gray Ring Gray Plug Gray Distributor O ring Retainer NOTE The WS1CS downflow piston is a solid amber color The WS1CS upflow piston is black and amber EFFECTIVE MAY 2012 FORM TECHCS MANUAL N GIES 847 888 6924 swtwater BLUFF 990 com e WEB SITE www info swtwater com MAIL E
4. SAFE TECHNOLOGIES NC OPERATION amp INSTRUCTION MANUAL TECH CS SERIES CONTROL VALVES FILTERS SOFTENERS CONDITIONERS MINE Les AE Wie CS AE MAY 2012 Table of Contents 3 Control Valve Function 4 Cycles of Operation 4 Table 1 Regeneration Cycles for Softening 4 Table 2 Regeneration Cycles for Filtering 5 Table 3 Downflow Softener Program Codes for WS1CS or WS1 25CS 5 Table 4 Upflow Softener Program Codes for WS1CS or WS1 25CS 5 Table 5 Downflow Regenerating Filter Program Codes for WS1CS or WS1 25CS 5 Table 6 Downflow Non Regenerating Filter Program Codes for WS1CS or WS1 25CS 6 Table 7 Time Clock and Demand Initiated Regeneration DIR Options 7 General Instructions 8 Table 8 Setting Options 9 Softener Setup 10 Filter Setup 11 Installer Displays amp Settings 12 User Displays amp Settings 12 General Operation 12 Regeneration Mode 12 Manual Regeneration 13 Set Time of Day 13 Power Loss 13 Error Message 13 Diagnostics 15 Valve History 16 Drawings and Part Numbers 16 Front Cover and Drive Assembly 17 WS1CS Drive Cap Assembly Downflow Piston Upflow Piston Regenerant Piston 8 Spacer Stack Assembly 18 WS1 25CS Drive Cap Assembly Downflow Piston Upflow Piston Regenerant Piston 8 Spacer Stack Assemblies 19 WS1CS and WS1 25CS Identification 19 WS1CS with 1 050 inch
5. Error and a number are alternately flashing on the display contact the OEM for help This indicates that the valve was not able to function properly Diagnostics STEP 1 DI Press and A simultaneously for three seconds If screen in Step 2 DI does not appear in 5 seconds the lock on the valve is activated To unlock press W NEXT A and SET CLOCK in sequence then press V and A simultaneously for 3 seconds STEP 2 DI Days Since Last Regeneration This display shows the days since the last regeneration occurred Press the NEXT button to go to Step 3 DI Press REGEN to exit Diagnostics STEP 3 DI Gallons Since Last Regeneration This display shows the number of gallons that have been treated since the last regeneration This display will equal 0 zero if a water meter is not installed Press the NEXT button to go to Step 4 DI Press REGEN to return to previous step Diagnostics continued on next page Page 14 STEP 4 DI STEP 5 DI STEP 6 DI SET a AT STEP 7 DI A 1155 w Hl SET S Des T A TV STEP 10 DI SET RETURN TO NORMAL MODE STEP 4 DI Gallons Reserve Capacity Used for Last 7 Days If the valve is set up as a softener a meter is installed and Gallons Capacity Step 7 SS Page 9 is set to Auto this display shows Day 0 for today and flashes the Reserve Capacity Pressing the A button will show Day 1 which would be yesterday a
6. If a power loss lasts less than 8 hours and the time flashes on and off the time of day should be reset and the non rechargeable battery should be replaced 1 Noryl is a trademark of General Electric Page 4 Cycles of Operation Table 1 below shows the order of the cycles when the valve is set up as a softener It allows the option of having the regenerant refill after the rinse cycle or have the regenerant prefill before regeneration If chosen to have the regenerant prefill before regeneration the prefill starts two hours before the regeneration time set During the 2 hour period in which the brine is being made treated softened water is still available For example regeneration time 2 00am prefill option selected downflow softener Fill occurs at 12 00am start of backwash cycle occurs at 2 00am Tables 3 and 4 Page 5 show the length of the cycles when different program codes are selected Table 1 Regeneration Cycles for Softening See NOTE on page 3 WS1CS amp WS1 25CS Downflow WS1CS amp WS1 25CS Downflow WS1CS amp WS1 25CS Upflow WS1CS amp WS1 25CS Upflow Regenerant Refill After Rinse Regenerant Prefill Regenerant Refill After Rinse Regenerant Prefill 1st Cycle Backwash 1st Cycle Fill 1st Cycle Regenerate 1st Cycle Fill 2nd Cycle Regenerate 2nd Cycle Service 2nd Cycle Backwash 2nd Cycle Service 3rd Cycle Second Backwash 3rd Cycle Backwash 3rd Cycle Rinse 3rd Cycle Regenerate
7. press NEXT and V simultaneously for 3 seconds STEP 2 SS Mode Choose SOFTENING using or A buttons Press NEXT to go to Step 3 SS Press REGEN to exit Softener Setup STEP 3 SS Refill Set Refill Option using W or A buttons PoST to refill the brine tank after the final rinse or to refill the brine tank two hours before the regeneration time set Press NEXT to go to Step 4 SS Press REGEN to return to previous step STEP 4 SS Program Code Enter the desired program code from Table 3 or Table 4 Page 5 Prior to selecting a Program Code verify the correct valve body main piston regenerant piston and stack are being used and that the injector or injector plug s are in the correct locations See Compliance Table in WS1 and WS1 25 Drawings and Service Manual Press NEXT to go to Step 5 55 Press REGEN to return to previous step STEP 5 SS Hardness Enter the ion exchange capacity in grains of hardness as calcium carbonate for the system based on test data using V or A buttons Press NEXT to go to Step 6 SS Press REGEN to return to previous step STEP 6 SS Salt Enter the pounds of salt per regeneration using W or A buttons Press NEXT to go to Step 7 SS Press REGEN to return to previous step STEP 7 SS Gallons Capacity Set Gallons Capacity using V or A buttons AUTO reserve capacity automatically estimated and gallons capacity automatically calculated from grains capacity
8. Distributor Tube Opening Identification 19 WS1 25CS with 1 32 inch Distributor Tube Opening Identification 19 WS1 25CS with 32mm Distributor Tube Opening Identification Page 3 Control Valve Function This glass filled Noryl 1 or equivalent fully automatic control valve is designed as the primary control center to direct and regulate all cycles of a water softener or filter When the WS1CS or WS1 25CS control valve is manufactured as a softener the control valve can be ordered to perform downflow or upflow regeneration When the WS1CS or WS1 25CS control valve is set up as a filter the control valve can be set to perform downflow regeneration or simply backwash The control valve can be set to regenerate on demand consumption of a predetermined amount of water and or as a time clock passage of a particular number of days The control valve can be set so that a softener can meet the Water Quality Association WQA Standard S100 or NSF ANSI Standard 44 efficiency rating NOTE It is NOT recommended to change control valves from downflow to upflow brining or vice versa in the field The valve bodies for downflow and upflow are unique to the regeneration type and should not be interchanged A mismatch of valve body and regeneration piston will result in hard water bypass during service The control valve is compatible with a variety of regenerants and resin cleaners The control valve is capable of routing the flow of water in the necessary pat
9. Regenerant Refill After Rinse Regenerant Prefill 1st Cycle Backwash 1st Cycle Fill 1st Cycle Backwash 2nd Cycle Regenerate 2nd Cycle Service 2nd Cycle Rinse 3rd Cycle Second Backwash 3rd Cycle Backwash 3rd Cycle Second Backwash oo Second Backwash is optional Second rinse only occurs if Second Backwash option is selected Table 3 Downflow Softener Program Codes for WS1CS or WS1 25CS Program 1st Brine Slow 2nd Code Backwash Rinse Backwash 5 5 W 5 NO A 0 W va U u a ES N ea ek li li ap _ U U N O1 N amp O1 CO1 C1 e U ap 0145 10 10 65 __ 10 65 aa 16 16 605 __6_ 75 0 N A C1 EM _ 9 _ RR RSS NIN IN IN IN OJO N O1 O1 A O NO ERN O O A O O N N T N e O N 5 Table 4 Upflow Softener Program Codes for WS1CS or WS1 25CS Program 1st Brine Slow 2nd Code Backwash Rinse Backwash Table 5 Downflow Regenerating Filter Program Codes for WS1CS or WS1 25CS Table 6 Downflow Non Regenerating Filter Program Codes for WS1CS or WS1 25CS Program 1st 1st 2nd 2nd Code Backwash Fast Rinse Backwash Fast Rinse P80 NOTE
10. and water hardness oFF regeneration based on day override number of gallons 20 to 50 000 See Table 8 Setting Options Page 8 for more detail Press NEXT to go to Step 8 SS Press REGEN to return to previous step STEP 8 SS Regen Time Set Regeneration Time Option using W or A buttons NORMAL means regeneration will occur at the preset time on 0 means regeneration will occur immediately when the gallons capacity reaches 0 zero or NORMAL on 0 means regeneration will occur at one of the following the preset time when the gallons capacity falls below the reserve or the specified number of days between regenerations is reached whichever comes first or after 10 minutes of no water usage when the gallon capacity reaches 0 zero See Table 8 Setting Options Page 8 for more detail Press NEXT to exit Softener Setup Press REGEN to return to previous step Page 10 STEP 1 FS REGEN SET CLOCK STEP 2 FS SET FILTERING SET di ver V wem SET STEP 4 5 P 10 HEB FILL SET CLOCK STEP 6 FS SET SET SET TIME REGEN l1 NORMAL A V jum RETURN TO NORMAL MODE Filter Setup This is a quick reference setup procedure STEP 1 FS Press NEXT and simultaneously for 3 seconds If screen in Step 2 FS does not appear in 5 seconds the lock on the valve is activated To unlock pr
11. the REGEN button for three seconds The system will begin to regenerate immediately The control valve may be stepped through the various regeneration cycles by pressing the REGEN button Page 12 User Displays 8 Settings General Operation CAPACITY REMAINING When the system is operating one of two displays will be shown Pressing NEXT will alternate between the displays One of the displays is always the current Time of Day The second display is one of the following Days Remaining or Capacity Remaining Days Remaining is the number of days left before the system goes through a regeneration cycle Capacity Remaining is the number of gallons that will be treated before the system goes through a regeneration cycle The user can scroll between the displays as desired REGEN TODAY will show if a regeneration is expected Tonight If the system has called for a regeneration that will occur at the preset time of regeneration the words REGEN TODAY will appear on the display When water is being treated i e water is flowing through the system the word SOFTENING or FILTERING flashes on the display if a water meter is installed Regeneration Mode Typically a system is set to regenerate at a time of low water usage An example of a time with low water usage is when a household is asleep If there is a demand for water when the system is regenerating untreated water will be used BACKWASH When the system begin
12. A regeneration will occur if the actual Reserve Capacity is less than the Gallons Capacity remaining The actual Reserve Capacity is calculated by using the estimated Reserve Capacity and adjusting it up or down for actual usage The estimated Reserve Capacity for a given day of the week is the maximum value stored for the last three non trivial water usages i e more than 20 gallons per day in seven day intervals General Instructions The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation These procedures are Softener Setup Filter Setup Installer Displays amp Settings User Displays amp Settings Diagnostics Valve History p UII D II These procedures can be accessed in any order Details on each of the procedures are provided on the following pages At the discretion of the manufacturer the field technician can access all settings To lock out access to Diagnostic and Valve History displays and modifications to settings except Hardness Day Override Time of Regeneration and Time of Day by anyone but the manufacturer press W NEXT A and SET CLOCK in sequence after settings are made To unlock so other displays can be viewed and changes can be made press W NEXT A and SET CLOCK in sequence When in operation normal user displays such as Time of Day Capacity Remaining or Days Remaining are shown When stepping through a procedure if no buttons are pr
13. For non regenerant filters 1 The regenerant piston is removed 2 Injector plugs are installed in both the UP and DN holes under the injector cap NOTE The program codes listed on this page should be used only as a guideline Any program code listed can be applied to a softener or filter application for WS1CS valves Page 6 Table 7 Time Clock and Demand Initiated Regeneration DIR Options Reserve Capacity gou Regenerant CHRO Day Override n g Only y Capacity yao If desired enter a value less than ves Yes Yes Any Number estimated capacity Automatically calculated Any Number Yes Yes j Ceara enter je uc c Yes Yes Yes Any Number Any Number estimated capacity Kon None Day Override and Gallons Capacity can not both be set to oFF at the same time The control valve with a water meter can be set for Demand Initiated Regeneration DIR only Time Clock operation only or DIR and Time Clock whichever comes first depending upon what settings are selected for Day Override and Gallons Capacity 2 See Table 7 above If a control valve does not contain a meter the valve can only act as a Time Clock and Day Override should be set to any number and Gallons Capacity should be set to OFF For DIR Softeners there are two options for setting the Gallons Capacity Step 7 SS Page 9 or Step 6 FS Page 10 The Gallons Capacity is automatically calculated if set to AUTO Reserve Capacity is aut
14. GEN to return to previous step DAY AL dix en A V nom m 235 SET dox c A V eem HIE aleja RETURN TO NORMAL MODE NOTE Values in Steps 3 VH through 7 VH cannot be reset Page 16 Front Cover and Drive Assembly n WA Mon on 3 ioven wesies Dive Braekel ant Sing ip 25 Board wih Batey 1 _ s iovo Dine Reduing f gt on wstsbmeGertne WS1CS AC Adapter 120V 12V Drawing Number Parts 2 through 6 may be purchased as a complete assembly Part No LC V3002 WS1CS Drive Assembly AC Adapter US International Supply Voltage 120 VAC 230 VAC Supply Frequency 60 Hz 50 Hz Output Voltage 12 VAC 12 VAC Output Current 500 mA 500 mA When replacing the battery align Correct positives and push down to fully seat Orientation Battery lt Battery replacement is 3 volt lithium coin cell type 2032 GS Battery Fully Seated Page 17 WS1CS Drive Cap Assembly Downflow Piston Upflow Piston Regenerant Piston 8 Spacer Stack Assembly n ive P N LC V3011 is labeled with DN and P N LC V3011 01 is labeled with UP NOTE The regenerant piston is not used in backwash only applications Black Plug Page 18 WS1 25CS Drive Cap Assembly Downflow Piston Upflow Piston Regenerant Piston 8 Spacer Stack Assembly Lova
15. Press the NEXT button to go to Step 8 DI Press REGEN to return to previous step STEP 8 DI Gallons Total Used Since Last Reset The total number of gallons used since last reset will be displayed This display will equal 0 zero if a water meter is not installed Press the NEXT button to go to Step 9 DI Press REGEN to return to previous step STEP 9 DI Days Total Number Since Last Reset The total number of days the control valve has been in service since last reset will be displayed Press the NEXT button to go to Step 10 DI Press REGEN to return to previous step STEP 10 DI Regenerations Total Number Since Last Reset The total number of regenerations that have occurred since last reset will be displayed Press the NEXT button to exit Diagnostics Press REGEN to return to previous step When desired all information in Diagnostics may be reset to zero when the valve is installed in a new location To reset to zero press NEXT and V buttons simultaneously to go to the Service screen and release Press V and A simultaneously to reset Diagnostic values to zero Screen will return to User Display Page 15 Valve History STEP 1 VH 1 VH STEP 1 VH Press V and A simultaneously for three seconds and release Then press V and A simultaneously again and release If screen in Step 2 VH dex Net AC res does not appear in 5 seconds the lock on the valve is activated To unlock press NEXT A and SET CLOCK in seq
16. STEP 7 FS Regen Time Set Regeneration Time Option using W or A buttons NORMAL means regeneration will occur at the preset time on 0 means regeneration will occur immediately when the gallons capacity reaches 0 zero or NORMAL on 0 means regeneration will occur at one of the following the preset time when the specified number of days between regenerations is reached or after 10 minutes of no water usage when the gallon capacity reaches 0 zero See Table 8 Setting Options Page 8 for more detail Press NEXT to exit Filter Setup Press REGEN to return to previous step SET CLOCK SET HARDNESS STEP 1 15 CATV em STEP 2 15 cu ser i CLOCK RETURN TO NORMAL MODE Sele AT STEP 3 15 Zn CV Ten STEP 5 15 Page 11 Installer Displays amp Settings STEP 1 IS Press NEXT and A simultaneously for 3 seconds STEP 2 IS Hardness Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the V or A buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon can be increased if soluble iron needs to be reduced This display will show nA if FILTERING is selected in Step 2 FS Page 10 or if AUTO is not selected in Step 7 SS Page 9 Press NEXT to go to Step 3 IS Press REGEN to exit Installer Displays amp Settings
17. acity reaches 0 Time of regeneration will not be allowed to be set because regeneration will always occur Reserve capacity automatically estimated NORMAL Regeneration occurs at the next Regen Set Time when gallons capacity falls below AUTO em Any number the reserve capacity or the specified number of days between regenerations is reached or regeneration occurs after 10 minutes of no water usage when gallon capacity reaches 0 Reserve capacity not automatically estimated NORMAL Regeneration occurs at the next Regen Set Time when the specified number of Any number Any number on 0 days between regenerations is reached or regeneration occurs after 10 minutes of no water usage when gallon capacity reaches 0 Reserve Capacity estimate is based on history of water usage NOTE Filters should only use the shaded options on O Reserve capacity automatically estimated Regeneration occurs when gallons capacity falls below the reserve capacity at the A LY SET CLOCK SET SOFTENING l AA STEP 3 55 Sa STEP 4 55 SET P Ee T A TV Tem STEP 5 55 Tee SET WF on RETURN TO NORMAL MODE Page 9 Softener Setup This is a quick reference setup procedure STEP 1 SS Press NEXT and Y buttons simultaneously for 3 seconds If screen in Step 2 SS does not appear in 5 seconds the lock on the valve is activated To unlock press W NEXT A and SET CLOCK in sequence then
18. ess W NEXT A and SET CLOCK in sequence then press NEXT and WV simultaneously for seconds STEP 2 FS Mode Choose FILTERING using Y or A buttons Press NEXT to go to Step 3 FS Press REGEN to exit Filter Setup STEP 3 FS Refill Set Refill Option using W or A buttons PoST to refill the brine tank after the final rinse or to refill the brine tank two hours before the regeneration time set Press NEXT to go to Step 4 FS Press REGEN to return to previous step STEP 4 FS Program Code Enter the desired program code from Table 2 Table 5 or Table 6 Page 5 Prior to selecting a Program Code verify the correct valve body main piston regenerant piston and stack are being used and that the injector or injector plug s are in the correct locations See Compliance Table in WS1 and WS1 25 Drawings and Service Manual Press NEXT to go to Step 5 FS Press REGEN to return to previous step STEP 5 FS Refill Volume Enter oFF if regenerant is not used i e backwash only or enter the refill volume in gallons using W or A buttons Press NEXT to go to Step 6 FS Press REGEN to return to previous step STEP 6 FS Gallons Capacity Set Gallons Capacity using V or A buttons oFF regeneration based on day override number of gallons 20 to 50 000 See Table 8 Setting Options Page 8 for more detail Press NEXT to go to Step 7 FS Press REGEN to return to previous step
19. essed within five minutes the display returns to a normal user display Any changes made prior to the five minute time out are incorporated The one exception is the Current Flow Rate display under the Diagnostic procedure The Current Flow Rate display has a 30 minute time out feature To quickly exit Softener Setup Filter Setup Installer Displays amp Settings Diagnostics or Valve History press SET CLOCK Any changes made prior to the exit are incorporated When desired all information in Diagnostics may be reset to 0 zero when the valve is moved to a new location To reset to 0 zero press NEXT and V buttons simultaneously to go to the Service screen and release Press A and V simultaneously to reset Diagnostic values to 0 zero Screen will return to User Display Sometimes it is desirable to have the valve initiate and complete two regenerations within 24 hours and then return to the preset regeneration procedure It is possible to do a double regeneration if the control valve is set to NORMAL or NORMAL on 0 in Step 8 SS Page 9 or Step 7 FS Page 10 To do a double regeneration 1 Press the REGEN button once REGEN TODAY will flash on the display 2 Press and hold the REGEN button for 3 seconds until the valve regeneration initiates Once the valve has completed the immediate regeneration the valve will regenerate one more time at the preset regeneration time Page 8 Table 8 Setting Options Gallons Rege
20. hs to regenerate or backwash water treatment systems The injector regulates the flow of brine or other regenerants The control valve regulates the flow rates for backwashing rinsing and the replenishing of treated water into a regenerant tank when applicable The control valve uses no traditional fasteners e g screws instead clips threaded caps and nuts and snap type latches are used Caps and nuts only need to be firmly hand tightened because radial seals are used Tools required to service the valve include one small blade screwdriver one large blade screwdriver pliers and a pair of hands A plastic wrench is available which eliminates the need for screwdrivers and pliers Disassembly for servicing takes much less time than comparable products currently on the market Control valve installation is made easy because the distributor tube can be cut 0 5 inch above to 0 5 inch below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distributor baskets The AC adapter power pack comes with a 15 foot power cord and is designed for use with the control valve The AC adapter power pack is for dry location use only The control valve remembers all settings for up to 8 hours if the power goes out and the battery is not depleted After 8 hours the only item that needs to be reset is the time of day other values are permanently stored in the nonvolatile memory
21. in salt fill with salt and wait at least two hours before regenerating SET 7 STEP 2 TD SET STEP 2 DI SET SE TTA Ten SET di Page 13 Set Time of Day The user can also set the time of day Time of day should only need to be set after power outages lasting more than 8 hours if the battery has been depleted and a power outage occurs or when daylight saving time begins or ends If a power outage lasting more than 8 hours occurs the time of day will flash on and off which indicates the time of day should be reset If a power outage lasts less than 8 hours and the time of day flashes on and off the time of day should be reset and the battery replaced STEP 1 TD Press SET CLOCK STEP 2 TD Current Time Hour Set the hour of the day using W or A buttons AM PM toggles after 12 Press NEXT to go to Step 3 TD STEP 3 TD Current Time Minutes Set the minutes of the day using W or A buttons Press NEXT to exit Set Clock Press REGEN to return to previous step Power Loss If the power goes out the system will keep time for up to 8 hours or until the battery is depleted If a power outage of more than 8 hours occurs the time of day will flash on and off which indicates the time of day should be reset The system will remember the rest If a power outage lasts less than 8 hours and the time of day flashes on and off the non rechargeable battery should be replaced Error Message If the word
22. m is set to on 0 i e to immediately regenerate when the Gallons Capacity reaches zero 2 Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration The user cannot cancel this request except by resetting the control by pressing NEXT and REGEN buttons simultaneously for 3 seconds A unique feature of this control valve is the ability to display actual water usage for the last 63 days The values are initially stored as This means the value is unknown As days pass values are stored as 0 for no flow or the actual number of gallons The counting of the gallons starts at the regeneration time If no regeneration time can be set i e when the valve is set for immediate regeneration the counting of gallons starts at 12am Day 1 is yesterday Day 2 the day before yesterday etc As new values are added the oldest history disappears 2 See Installer Displays amp Settings Step 3 IS Page 11 Softener Setup Step 7 SS Page 9 and Filter Setup Step 6 FS Page 10 for explanations of Day Override and Gallons Capacity Page 7 Another unique feature is that the valve automatically calculates a reserve capacity when set up as a softener with Gallons Capacity set to AUTO and the Regeneration Time Option set to Normal or Normal on 0 The actual Reserve Capacity is compared to the Gallons Capacity remaining immediately prior to the preset regeneration time
23. nd flashes the Reserve Capacity used Pressing the A button again will show Day 2 the day before yesterday and the Reserve Capacity Keep pressing the A button to show the gallons for Days 3 4 5 and 6 The Y button can be pressed to move backwards in the Day series Press the NEXT button at any time to go to Step 5 DI Press REGEN to return to previous step STEP 5 DI Gallons 63 Day Usage History This display shows Day 1 for yesterday and flashes the number of gallons treated yesterday Pressing the A button will show Day 2 which would be the day before yesterday and flashes the number of gallons treated on that day Continue to press the A button to show the maximum number of gallons treated for the last 63 days This display will show dashes if a water meter is not installed Press the NEXT button at any time to go to Step 6 DI Press REGEN to return to previous step STEP 6 DI Flow Rate Current Turn the water on at one or more taps in the building The flow rate in gallons per minute will be displayed If the flow stops the value will fall to O zero in a few seconds This display will equal O zero if a water meter is not installed Press the NEXT button to go to Step 7 DI Press REGEN to return to previous step STEP 7 DI Flow Rate Maximum Last 7 Days The maximum flow rate in gallons per minute that occurred in the last 7 days will be displayed This display will equal O zero if a water meter is not installed
24. neration Day Capacity Time Option Override Reserve capacity automatically estimated AUTO NORMAL OFF Regeneration occurs when gallons capacity falls below the reserve capacity at the next Regen Set Time Reserve capacity automatically estimated AUTO NORMAL Any number Regeneration occurs at the next Regen Set Time when gallons capacity falls below the reserve capacity or the specified number of days between regenerations is reached Reserve capacity not automatically estimated Regeneration occurs the next Regen Set Time when gallons capacity reaches 0 Reserve capacity not automatically estimated OFF NORMAL Any number Regeneration occurs at the next Regen Set Time when the specified number of days between regenerations is reached Reserve capacity not automatically estimated Any number NORMAL Any number Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the specified number of days between regenerations is reached Reserve capacity not automatically estimated Regeneration occurs immediately when gallons capacity reaches 0 Time of AUTO on 0 regeneration will not be allowed to be set because regeneration will always occur we AUTO NORMAL on 0 next Regen Set Time or regeneration occurs after 10 minutes of no water usage when gallon capacity reaches 0 OFF when gallons capacity reaches 0 Reserve capacity not automatically estimated oFF Regeneration occurs immediately when gallons cap
25. omatically estimated based on water usage if AUTO is used The other option is to set the Gallons Capacity to a specific number If a specific number is set Reserve Capacity is 0 zero unless the value is manually set i e the manufacturer intentionally sets the Gallons Capacity number below the calculated capacity of the system The control valve can also be set to regenerate immediately or at the next regeneration time by changing the Regeneration Time Option Step 8 SS Page 9 or Step 7 FS Page 10 There are three choices for settings 1 NORMAL means regeneration will occur at the preset regeneration time 2 on 0 means regeneration will occur when the Gallons Capacity reaches 0 zero 3 NORMAL and on 0 NORMAL on 0 means the regeneration will occur at the preset regeneration time unless the Gallons Capacity reaches 0 zero If the Gallons Capacity reaches 0 zero the regeneration will begin 10 minutes after no water usage The user can initiate manual regeneration The user has the option to request the manual regeneration at the delayed regeneration time or to have the regeneration occur immediately 1 Pressing and releasing the REGEN button will flash REGEN TODAY on the display and the regeneration will occur at the delayed regeneration time The user can cancel the request by pressing and releasing the REGEN button This method of manually initiating regeneration is not allowed when the syste
26. s ws1 2508 Spacer Sak Uptow assemey s tewsme wszscspwesepme 1 _ 4a wS1 25CS Piston Downfow assemey J O ooo o s o twm AAA 7 Tube Opening 1 32 inch 1 NOTE The regenerant piston is not used in backwash only applications Grey Plug on all WS1 25 bodies Grey Ring Grey Distributor O ring retainer Only for valves that have a 32mm Distributor Tube Opening Page 19 WS1CS 8 WS1 25CS Identification WS1CS with 1 050 inch Distributor Tube Opening Identification Spacer Color Gray 5 A Sa Sen AE 3 ki qoa p p i m JM wu Li cu d abo ai a 1 25 inch Black Plug 1 25 inch NOTE The WS1CS downflow piston is a solid amber color The WS1CS upflow piston is black and amber WS1 25CS with 1 32 inch Distributor Tube Opening Identification DOWNFLOW amp BACKWASH UPFLOW Spacer Color Spacer Color Gray 1 25 inch 5 1 25 inch Gray Plug NOTE The WS1CS downflow piston is a solid amber color The WS1CS upflow piston is black and amber WS1 25CS with 32mm Distributor Tube Opening Identification DOWNFLOW amp BACKWASH UPFLOW Spacer Color Black Spacer Color Gray WA delet Ti a 1 25 inch A Bos Y DAN mt DU LXV V AA wel ay MA IS lh qu p koi A p AVAN
27. s to regenerate the display will change to include information about the step of the regeneration process and the time remaining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed Manual Regeneration CAPACITY REMAINING REGEN Jeli REGEN MA Sometimes there is a need to regenerate the system REGEN TODAY will sooner than when the system calls for it usually referred to as manual regeneration There may be a period of heavy water usage because of guests ora SET wa pe To initiate a manual regeneration at the preset delayed regeneration time when the regeneration time option is set to NORMAL or NORMAL on 0 press and release REGEN The words REGEN TODAY will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the request Flash if a regeneration is expected Tonight Note If the regeneration time option is set to on 0 there is no set delayed regeneration time so REGEN TODAY will not activate if REGEN button is pressed To initiate a manual regeneration immediately press and hold the REGEN button for three seconds The system will begin to regenerate immediately The request cannot be cancelled Note For softeners if brine tank does not conta
28. uence then press V and A simultaneously for 3 seconds and release Then press W and A simultaneously LOC Ble seems STEP 2 VH Software Version This display shows the software version of the valve Press the NEXT button to go to Step 3 VH Press REGEN to exit Valve History STEP 3 VH Flow Rate Maximum Since Startup This display shows the maximum flow rate in gallons per minute that has occurred since startup This display will equal O zero if a water meter is not installed Press the NEXT button to go to Step 4 VH Press REGEN to return to previous step STEP 4 VH Gallons Total Used Since Startup This display shows the total gallons treated since startup This display will equal O zero if a water meter is not installed Press the NEXT button to go to Step 5 VH Press REGEN to return to previous step STEP 5 VH Days Total Since Startup This display shows the total days since startup Press the NEXT button to go to Step 6 VH Press REGEN to return to previous step STEP 6 VH Regenerations Total Number Since Startup This display shows the total number of regenerations that have occurred since startup Press the NEXT button to go to Step 7 VH Press REGEN to return to previous step STEP 7 VH Error Log This display shows a history of the last 10 errors generated by the control during operation Press the W or A buttons to review each error recorded Press the NEXT button to exit Valve History Press RE