1.  and remove ice chute    5  The breaker may be removed from the auger  and evaporator without disturbing the auger    a  Use spanner wrench and unscrew breaker  cover from breaker  left hand threads    b  Unscrew auger stud from top of auger    c  Unscrew 4 allen head cap screws holding  breaker to evaporator    d  Lift up  and remove breaker bearing assembly  from auger  amp  evaporator    6  Service the bearing  Check for rust  rough spots  and damage     Step 5  a Step 5 b    ICE SWEEP       SPANNER  WRENCH  use  on units built  before 1991     ZT   BREAKER    COVER             a  The bearing is pressed into the breaker  to  remove the bearing and replace it an arbor press  is needed    b  Replace lower seals before installing new  bearing in breaker    Note  seals must be pressed in with a tool pushing  against the outer edge only  they will not install by  hand    Replace parts as required  Re grease bearing with  Scotsman part no  19 0609 01 bearing grease   Replace top seal  and check the o rings  replace if  cut or torn    7  Reverse to reassemble  specific tools and  materials are required to install properly    a  Add food grade grease such as Scotsman part  number 19 0569 01 to the seal area before  installing on the auger    b  Check the seal to shaft areas for cuts  or rough  spots  none are permitted     Step 5 c and Step 6    BEARING __        C3 SEALS  es  cy f    lar   SLOTTED        Fret I COLLAR  Gi          Ra     amp                           Va       DIV
2.  circuit board with the ELECTRICAL POWER OFF     checked out  Make all connections to the    ITT  INSTRUCTIONS FOR USING TESTER  model FC1  Optional  order part no  A33942 001      These instructions assume that the unit will not run  and prior investigation of electric power   controls  and mechanical parts indicates that the electronic circuit may be at fault      If the  Reset  indicator  located in the  reset  switch  is off and the  NO WATER  indicator is lit   but inspection shows that the water level in the reservoir is above the top of the water level  sensor  OR the  BIN EMPTY  indicator is off while inspection shows that the ice level sensors are    properly aligned  clean and not obstructed  use the  Bin Control Note  All testing is done with the  electrical power on  the master switch on  and all  reset switches    reset      1  Unplug    photo trans    and    LED    connectors from  the circuit board   2  Plug    photo trans    and    LED    connectors from  the tester into the circuit board    a  Move the    bin full    switch on the tester to Full   The light on the tester should be ON   If the light on the tester is not on  the circuit board  should be replaced          PHOTO TRANS    LIGHT GOES       tester as follows    b  If the light on the tester IS on  move the    bin  full    switch to Bin Empty  The light on the tester  should go OFF  and the Bin Empty light on the  circuit board should go ON    If the Bin Empty light is ON  wait 10 20 seconds for  the
3.  machine to start  if the machine starts  replace  the ice level sensors    If the Bin Empty light does not come ON  the  circuit board should be replaced        LIGHT GOES ON    OFF       ON  SWITCH TO   BIN EMPTY   SWITCH TO   FULL   August 1994       Page 26    CIRCUIT BOARD TESTING    Water Level   1  Unplug    water sen    connector from control  board    2  Plug    water sen    connector from Scotsman  tester into circuit board    a  Move    water    switch on tester to No Water  position  The No Water light on the circuit board  should go ON  If not  replace the circuit board    b  Move the    water    switch on the tester to the  Water position  The No Water light on the board          should go OFF  If not replace the circuit board  If    the light does go off  replace the water level sensor   If the Bin Empty light is ON  wait 10 20 seconds for    the machine to start  The machine should start     August 1994    Page 27       FM2400RH       
4.  running with a minimum of    problems     Maintenance and Cleaning should be scheduled at a minimum of twice per year   LLL    MTT TTNN AARNING I HT  Electrical power will be ON when doing in  place cleaning  Switch it OFF before  completing the cleaning procedures   LLL  ICEMAKING SYSTEM  In place cleaning    1  Check and clean any water treatment devices   if any are installed     2  Pull out and remove the front panel    3  Move the ON OFF switch to OFF    4  Remove all the ice from the storage bin    5  Remove the cover to the water reservoir and  block the float up    6  Drain the water reservoir and freezer assembly  using the drain tube attached to the freezer water  inlet  Return the drain tube to its normal upright  position and replace the end cap    ITA TTINNARNING I THT  Scotsman Ice Machine Cleaner contains  Phosphoric and Hydroxyacetic acids  These  compounds are corrosive and may cause  burns  If swallowed  DO NOT induce vomiting   Give large amounts of water or milk  Call  Physician immediately  In case of external  contact  flush with water  KEEP OUT OF THE  REACH OF CHILDREN   A   7  Prepare the cleaning solution  Mix eight  ounces of Scotsman Ice Machine Cleaner with  three quarts of hot water  The water should be  between 90 115 degrees F    8  Slowly pour the cleaning solution into the water  reservoir until it is full  Wait 15 minutes  then  switch the master switch to ON     9  As the ice maker begins to use water from the  reservoir  continue to add m
5.  the  bin extension BX87  install heavy  duty leg kit KLP4 and place the bin  into position    Remove the paper tape from the bin  edge gasket  and install the bin  extension onto the B90    Remove the paper tape from the bin  extension top edge  and using a  mechanical lift  install the FM2400RH  onto the top of the storage bin  assembly    Fasten the ice machine to the bin  using  4  5 15 18 2 5  cap screws   Level the assembly by    a  Turning the leg levelers in or out  on the standard legs    b  Use shims under the heavy duty  legs of the KLP4    Locate the Nameplate  The  nameplate is located on the back  panel of the machine  and contains  the electrical characteristics  particular to the unit being installed                             BX87 BIN       EXTENSION          2  7 B90 STORAGE BIN       Refrigeration Installation  MUM AUTON   The skills of a refrigeration technician are required The FM2400RH 32B comes with a dry nitrogen  to connect the ice machine to the buildings holding charge  Purge and evacuate before  refrigeration system  connecting to a refrigeration system     TULL  Local Codes must be observed     A P trap should be installed where there will be  more than 10    of vertical rise in the suction line     FOR THE ELECTRICIAN  CONFORM TO ALL APPLICABLE CODES    August 1994  Page 3    FM2400RH    Electrical Connections     Locate the nameplate for the current requirements   and then determine the wire size and type per the  National Electric Code  The ma
6.  the master switch   but is otherwise ready to go  switching the master  switch to on and pressing the start reset switch  does the following      The bin empty light on the circuit board goes on    There is a 15 second delay    e  f there is enough water in the reservoir  the  circuit board will allow the machine to start up   Start up consists of     The liquid line relay and auger motor relay  become energized  connecting power to the  windings of the auger motor     The auger motor starts  and the centrifugal  switch closes  connecting power to the liquid  line valve coil       The liquid line valve opens  and the refrigerant  flows to the thermostatic expansion valve and  into the evpaorator       As ice goes past the ice level sensors  the bin  empty light will stay on  and the machine will  continue to run  unless the ice stays between  the sensors for more than 15 seconds  bin full    At that point  the bin empty light goes out  and  the machine shuts down     FM2400RH    Shut Down consists of     The liquid line relay opens     The liquid line valve closes  ice making stops      The auger motor is run by the circuit board for  2 5 more minutes  clearing out ice in the  evaporator  and then    The auger motor relay opens  and the auger  motor stops   If the ice level sensor is clear  bin empty  for more  than 15 seconds  the machine will start up again   Another purpose of the circuit board is to turn the  machine off if there is not enough water in the  machine      
7. 8    FM2400RH    A  Check the liquid line valve relay   The relay is on the circuit board  if it does not supply power to the liquid line valve  the  valve will not open   1  Check for power at the valve coil  if none   a  Check for power at the liquid line valve relay at the circuit board   If there is power at the relay  but none at the liquid line valve coil   Check for an open wire between the relay and the valve   2  Check the valve coil  If the coil is open  replace the liquid line valve   3  Check the auger drive motor centrifugal switch  If  when the drive motor is running   contact 4  black wire removed  has no power  and all of the above switches have been  checked  replace the centrifugal switch  or the drive motor   4  If the liquid line valve relay on the circuit board has power on the NO contact  but not on the COM  contact  replace the circuit board     August 1994  Page 19    FM2400RH  REMOVAL AND REPLACEMENT    WATER RESERVOIR   1  Shut off the water supply to the icemaker    2  Remove front panel and reservoir cover    3  To remove float only   A  models  pry the  mounting flanges apart enough to lift one float  pivot pin out of the flange hole  and pull float up  and out of the reservoir   B  models  disconnect  water inlet tube  push in the tab behind the  reservoir and pull valve assembly out of the  reservoir tank    4  To remove reservoir  disconnect water inlet  compression fitting at reservoir inlet    5  Remove drain hose from reservoir    6  Remove 
8. ADJUST THE TXV UNTIL THE EPR  HAS BEEN SET    The superheat setting is 4 8  F  Measure the  temperature of the evaporator outlet at the TXV  bulb  and check the low side pressure at the EPR  valve  Convert the pressure to temperature  using  a temperature pressure chart  and subtract the       amount from the outlet temperature  The result is  the superheat  Use an electronic thermometer     EPR  Evaporator Pressure Regulator Valve    This valve maintains a constant pressure on it   s  inlet  evaporators  side regardless of the pressure  on the outlet  suction  side  The EPR is factory set   adjust only if needed  After adjusting check TXV  superheat    Evaporators    Where the water is frozen into ice crystals  As the  water cools  it begins to turn into ice  and the  slowly turning auger lifts the ice  as it is being  made  and forces it up and out of the  breaker  or  spout where the extra water is compressed out of  the ice  The ice then drops through the chute  into  the storage bin     EPR VALVE 5 THERMO    THERMO VALVE    LIQUID LINE  VALVE                   EVAPORATOR             August 1994  Page 8    FM2400RH    COMPONENT DESCRIPTION  Control Box    Circuit Board  Controlling the ice machine  through sensors and relays  The sensors are  ice  level  and water level  The relays are for the gear  motor  with a built in time delay to clear the  evaporator of ice when the unit turns off  and for  the liquid line valve    Transformer  Supplies low voltage to the circuit  
9. D  SUPPLIED  WATER FILTER          WATER INLET    BIN DRAIN A       FLOOR DRAIN Eer                August 1994  Page 5    FM2400RH  FOR THE INSTALLER  Final Check List    1  Is the unit installed where the air and water  temperatures are within and will remain within the  limitations for the unit     2  Is there 6  clearance at the rear of the machine  for utility connections     3  Has the water supply line be checked for  pressures between 20 and 120     4  Has the unit been leveled     5  Has the shipping material been removed from  inside the cabinet     6  Have the electrical connections been made     7  Have the drains been installed and checked for  leaks     8  Has the refrigeration supply been installed and  checked for leaks     9  Has the bin and cabinet been wiped clean or  sanitized     10  Has the warranty registration card been  properly filled out and mailed to Scotsman     11  Has the owner been given the service manual  and been instructed on how to maintain the  icemaker     13  Has the owner been given the name and  telephone number of the local Scotsman service  agency     August 1994  Page 6    FM2400RH  INITIAL START UP    1  Remove the top and front panels  7  Switch on the other master switch  observe that   The liquid line valve opens  2  Open the water valve  and observe that the two The gearmotor runs  float reservoirs fill up with water and shut off  Within a short time  that side of the machine  begins to make ice   3  Switch on the electrical po
10. FM2400RH  TO THE OWNER OR USER     The service manual you are reading is intended to gearmotors  two liquid line valves  two control  provide you  and the maintenance or service boxes  two thermostatic expansion valves  and an  technician  with the information needed to install  EPR valve    start up  clean  maintain and service this ice   system     The FM2400RH  remote high side  is the freezer  portion of a commercial ice machine  It is designed  to be connected to the condensing section of a  refrigeration system  specifically a supermarket  R 502 system  It consists of two evaporators  two       Parts lists and wiring diagrams are in the center of this manual  printed on yellow paper     August 1994  Page 1    FM2400RH    FOR THE INSTALLER  Specifications    The FM2400RH is designed to fit the Scotsman  storage bins BH800 or B90  Leg kit KLP4 is  recommended when using both the B90 bin and  an extension     Installation Limitations  The FM2400RH is  BACK VIEW        lt         15 53        _      and performance  They meet or exceed the  standards of U L   N S F   and C S A    Scotsman assumes no liability or responsibility of  any kind for products manufactured by Scotsman  that have been altered in any way  including the  use of any parts and or other components not                 sie LINE CONNECTION 7    LIQUID LINE CONNECTION 12        o O                    he                 21 66     designed for indoor installations only  The machine  must also be in a controlle
11. IDER       August 1994  Page 21    FM2400RH  REMOVAL AND REPLACEMENT    TTT INNEXRNUNG IT TT    Disconnect electrical power  Handle the auger  with care  it has sharp edges     MTT    To Remove the Auger     Turn off the water to the machine  and unclip the  evaporator drain hose  pull it down and drain the  evaporator into the bin or a container     1  The top panel must be removed    2  Remove ice chute cover    3  Unscrew ice sweep    4  Loosen band clamp and remove ice chute body     5  The auger and breaker bearing may now be  removed as an assembly     a  Unscrew 4 allen head cap screws holding  breaker to evaporator     b  Lift up on breaker and remove auger from  evaporator     Note  If the auger is stuck  the breaker must be  removed from the auger     The breaker may be removed from the auger and    DIVIDER       evaporator without disturbing the auger     a  Use spanner wrench and unscrew breaker  cover from breaker  left hand threads     b  Unscrew auger stud from top of auger    c  Unscrew 4 allen head cap screws holding  breaker to evaporator    d  Lift up and remove breaker from evaporator   e  If the auger is stuck use a slide hammer type  puller to pull on the auger at the threaded hole   The size of that hole is 5 8  18     Inspect the auger  the critical areas of the auger  are    1  The auger body  It should be clean and  shining  Sometimes an auger will appear clean  when wet  but after it is dry it will be seen to be  stained  Scrub the auger with ice ma
12. When the water level in the reservoir falls  below the water level sensor  the machine will   shut down       When the water refills the reservoir  the   machine will start up again   Separate from the circuit board       f the spout switch opens  the machine will stop  immediately  through the relays on the circuit  board  and cause the reset switch on the circuit  board to light up  It must be manually reset at  the reset switch on the circuit board       The master switch is the manual control for  each system  but it is not a service disconnect     August 1994    Page 11    FM2400RH    OPERATION   Water Reservoir overflow or evaporator condensation is  Water enters the machine through the 3 8  male routed to the drain    flare at the rear of the cabinet  goes to the water Water cooled models have a separate water  reservoir which it enters through the float valve  circuit for the cooling water  it enters the fitting  The water then goes out the bottom of the at the rear  goes to the water regulating valve   reservoir tank to the bottom of the evaporator  then to the water cooled condenser and then    down the drain     WATER SCHEMATIC         WATER INLET          EVAPORATOR  WATER INLET    DRIP PAN DRAIN    August 1994  Page 12    OPERATION  Refrigeration    The remote high side LIQUID    supplies high pressure LINE  liquid R502 to the liquid a aioe eee   line connection on the Pe ae   ice machine  After the Sohal  sight glass  there are  two separate liquid lines   each 
13. a     FM2400RH    4  Place a small bead of food grade silastic sealant   such as 732 RTV or Scotsman part number  19 0529 01  on the area of the auger where the  water seal is to be mounted    5  Carefully push the water seal  rubber side  against the auger shoulder and the silastic    MMMM GAO TIONM TLL   Do not get any silastic onto the face of the seal   LLL   6  Allow the auger and seal to air dry until the  silastic is dry on the surface    7  If the original water seal was leaking  it  would be a good idea to inspect the interior of  the gearmotor           FOOD  EALANT  RE          August 1994  Page 23    FM2400RH    REMOVAL AND REPLACEMENT  Evaporator    To Replace the Evaporator     Assuming all the steps for removal of the thrust  bearing  breaker  auger  and water seal have been  performed      1  Shut the hand valves in the liquid and suction   lines to the evaporator being serviced  then   discharge the refrigerant    2  Unsweat the refrigerant connections    a  At the thermostatic expansion valve outlet   CAUTION    Heat sink the TXV body when unsweating or  resweating the adjacent tubing     b  At the suction line at the joint about 3  from the  evaporator   3  Remove the  evaporator     4  Unsweat the drier  from the liquid line    5  After installing a  new water seal in the  new evaporator  see   To Replace the  Water Seal   sweat in  the new evaporator at  the old connections   6  Install an new drier  in the liquid line    7  Evacuate the  system until  de
14. board    On Off Switch  Manual control for that side of the  machine    Reset Switch  Manual reset  Glows when the  unit shuts off from the ice discharge chute being  overftilled  pressure of the ice opening the  microswitch at the top of the chute     Not used on FM2400RH 32B         ON OFF SWITCH    TRANSFORMER    CIRCUIT  BOARD    TERMINAL STRIP    RESET SWITCH   Early Models Only     August 1994  Page 9    FM2400RH  COMPONENT DESCRIPTION  Evaporator       Evaporator  A refrigerated vertical tube filled Motor  A permanent split capacitor motor that  water and containing a water seal and auger  drives the gear reducer    Auger  A solid stainless steel double spiral auger  Bearing  As the ice is pushed up the evaporator   it pushes the ice crystals up to the top of the the auger is thrust down  and pressure from the  evaporator  auger thrust is taken up by this bearing     Water Seal  A two part  face  seal  the top half  rotating with the auger  the bottom half stationary   the sealing action being where the two seal  faces   meet     Ice Sweep  A plastic cap with  fingers   It revolves  with the auger to  sweep  the ice into the ice chute   Divider  Where the ice is compressed and much  of the extra water is squeezed out of it before it is          BEARING ICE SWEEP  DIVIDER  EVAPORATOR  WATER  SEAL       discharged into the bin     August 1994  Page 10    ELECTRICAL SEQUENCE    Refer the wiring diagram as needed   Each system is separate  If the machine is switched off at
15. chine cleaner  and hot water   MLINNARNINGITT LTT  Ice machine cleaner is an acid  Handle it with  extreme care  keep out of the reach of children   MTT  2  The water seal area  Because the auger has  been removed  the water seal will have to be  replaced  Remove the water seal top half from the  auger  and inspect the auger for minerals clean as  required        SLIDE HAMMER  PULLER       THREAD INTO THE  AUGER HERE       August 1994  Page 22    REMOVAL AND REPLACEMENT    MATT TLNN ARNUING  T THT  Disconnect the electrical power to the machine  at the building source BEFORE proceeding  with any repair   IAT   To Remove the Water Seal      Assuming all steps to remove the auger have  been performed      1  The gearmotor evaporator assembly will have to  be exposed     2  Remove the 4 hex head cap screws holding the  evaporator to the gearmotor assembly  Lift the  evaporator up and off of the gearmotor    3  Remove the snap ring or wire retainer from the  grove under the water seal    4  Pull or drive out the lower half of the water seal   To Replace the Water Seal     1  Lubricate the water seal with water  and push  the water seal into the bottom of the evaporator                            al res  RETAINING    s RING    slightly past the grove for the snap ring    2  Replace the snap ring and pull the water seal  down against it    3  The part of the water seal that rotates with the  auger must also be replaced  Remove the old part  from the auger and clean the mounting are
16. chine requires a    solid chassis to earth ground wire   Refer to the wiring diagram  The ice  machine should be connected to it   s  own electrical circuit  and be  individually fused    Voltage  when the unit is under full  load  must remain within the limitations  listed on page 2    LOW VOLTAGE CAN CAUSE  EQUIPMENT MALFUNCTION  AND OR DAMAGE   All external wiring should conform to  the National  State  and local electrical  codes  Usually the services of a  licensed electrician will be required     DETAIL OF  JUNCTION BOX    JUNCTION  BOX       POWER SUPPLY           SO ve l  on  Sa         AN a  ap          August 1994  Page 4    FM2400RH  FOR THE PLUMBER    CONFORM TO ALL APPLICABLE CODES    Drain System     All drains are of the gravity type  and must have a  minimum of 1 4  fall per foot of horizontal run  The  drains must be installed to conform to local  plumbing codes  The use of a vent at the machine  and at the bin will allow the system to drain  properly  Use only rigid tubing for drains  insulation  of the bin drain is recommended     SHUT OFF Se  Pa    Water Supply    The recommended water supply line is 3 8  O D   copper tubing  with a minimum operation pressure  of 20 PSIG  and a maximum of 120 PSIG   Connect to cold water using the male flare  connection at the back of the machine  Install a  shut off valve in an accessible space between the  ice maker and the water supply     3 8  MALE FLARE    3 4  FPT       VALVE SB    SS  e  4    VENT THIS DRAIN    FIEL
17. d environment where  the air temperature does not fall below 50  F   or  go above 100  F    The water temperature must be between 40  F   and 100  F    The electrical power supply must not drop below   5  of the lowest nameplate voltage or go above  10  of the highest nameplate voltage   SPECIFICATIONS    Scotsman Ice Systems are designed and  manufactured with the highest regard for safety          o      ELECTRICAL INLET       POTABLE WATER INLET 3 8  FLARE       DRAIN 3 4  FPT  specifically approved by Scotsman    Scotsman reserves the right to make design  changes and or improvements at any time   Specifications and designs are subject to change  without notice                                Model Number Dimensions  w o Bin  Ice Basic Minimum   Maximum BTU   s  H  x W  D  Type Electrical Circuit Fuse Required  Ampacity Size  FM2400RH 32B 27  X 42  X 24  Flake 208 230 60 1 2 7 15 16 000  August 1994    Page 2       FM2400RH  FOR THE INSTALLER    Select the Location    The unit can only be installed indoors TYPICAL INSTALLATION  ALLOW ROOM FOR SERVICE ACCESS  within the limitations described on   page 2    The ice machine will have to be   connected to the buildings R502 FM2400RH   refrigeration system  check to be  sure that the system has enough  extra capacity to handle a minimum  of additional 16 000 BTU   s per hour    110  F  liquid line temperature   assume a oF  evaporator  temperature     Storage Bin    Scotsman   s B90 will be the  presumed bin of choice  If using
18. evaporator inlet hose from reservoir   7  Remove mounting screws from reservoir  bracket  and remove reservoir from icemaker   8  Reverse to reassemble     FLOAT    2  ASSEMBLY       FLOAT  MOUNTING                      BIN CONTROLS  Ice Level Sensors    1  Disconnect electrical power    2  Remove front panel    3  Remove control box cover    4  Locate ice chute  at the base of the chute  in  front of and behind it are two plastic bin control  mounts    5  Slide each bin control to the left  and in the  control box  disconnect the electrical leads  connecting the bin control to the circuit board    6  Reverse to reassemble  be certain that the bin  controls are aligned so that the ice level sensors  are visible  centered  through the holes in the cube  chute     CHUTE    SLIDE BIN  CONTROLS  IN AND OUT            FLANGES  A Model  Internal  Plunger  Float Valve  B Model  A se   August 1994    Page 20    FM2400RH    REMOVAL AND REPLACEMENT  Bearing And Breaker    Note  Removal of the auger  water seal   evaporator and gearmotor must begin at the top of  the assembly    To Remove the Breaker Bearing Assembly   MTT HINNAARNUING T HT  Disconnect the electrical power to the machine  at the building source BEFORE proceeding  with any repair   I   1  Remove panels and disconnect electrical power   2  Unscrew three studs and remove ice chute  cover    3  Unscrew and remove ice sweep    4  Remove insulation halves from outside of ice  chute  loosen band clamp under ice chute  lift up 
19. formation on removal of these  parts  see REMOVAL AND REPLACEMENT    1  To remove the auger  remove front and top  panel  If top panel cannot be removed  or if there is  less than 6  clearance over the top of the machine   the gearmotor evaporator may be slid out for  service access  See Removal And Replacement   2  Remove 3 hex studs holding ice chute cover to  ice chute  and remove cover    3  Unscrew and remove ice sweep    4  Loosen band clamp under ice chute  and  remove ice chute from evaporator    5  Remove 4 allen head screws holding breaker to  evaporator    6  Pull up on breaker to remove auger    Allow the auger to dry  the stainless steel of the  auger and evaporator must be clean and bright   Clean the auger and evaporator as required  DO  NOT HONE THE EVAPORATOR    7  Replace the water seal    8  Reverse to reassemble     August 1994  Page 16    FM2400RH  SERVICE DIAGNOSIS  Condition   No Ice Being Produced    STATUS  NOTHING OPERATES    A  Check  Voltage to the unit  restore it if there is none  Compare to the nameplate     B  Check  The master switch  switch ON if off     C  Check  The reset switch   on the circuit board   depress and release the switch  If the still does  not start  check  the spout switch     D  Check the spout switch  It opens from excess pressure of ice inside the ice chute  this should only  happen when the machine does not shut off when the ice storage bin is full  This switch will reset  when the ice melts  but the machine will not resa
20. full  switch on the tester to the full position  The bin full light  on the tester should be ON  if not  replace the circuit board   If the bin full light on the tester is ON  move the tester switch to  bin empty   the light on the tester should go OFF and the bin empty light on the circuit  board should go ON  If not  replace the circuit board  If it does as above   and the machine still does not run  replace the ice level sensors   3  If the transformer is fine  and the  no water  light is ON  check the water level sensor   a  Check the water level in the reservoir  restore if low  If the water level is ok   b  Remove the water level sensor from the reservoir and clean the tip if dirty   CAUTION  THE TIP IS MADE OF GLASS  c  Replace the water level sensor  If the no water light is still on  check that the   water sen  plug is firmly plugged into the circuit board   d  If the no water light is still on   1  Unplug the  water sen  connector from the circuit board   2  Plug  water sen  connector from the Scotsman Electronic Control tester into  the circuit board   a  Move the water switch on the tester to  no water  and the no water light  on the circuit board should go on  If not  replace the board   b  Move the water switch to the  water  position  the no water light should  go off  if not  replace the circuit board   c  If after the above  the machine still will not run  replace the water level  sensor    STATUS  GEARMOTOR OPERATES  BUT NO ICE IS MADE    August 1994  Page 1
21. hydrated  then  weigh in the  nameplate charge   Check for leaks    8  Install auger   breaker  breaker  bearing assembly   and ice discharge  chute in reverse order  of disassembly  See   To Reassemble  Evaporator and Auger        BEARING           To Reassemble the Evaporator and Auger   1  After the gearmotor has been inspected  fasten  the evaporator to the gear motor  torque the bolts  to 110 inch pounds    2  Lower the auger into the evaporator barrel   slightly turning it to match up with the drive end   Do Not Drop Into the Evaporator    3  Complete the reassembly by reversing the  disassembly for the breaker  amp  thrust bearing  assembly     AUGER    EVAPORATOR    DRIP PAN    DIVDER BREAKER       August 1994  Page 24    FM2400RH    REMOVAL AND REPLACEMENT  Gearmotor    To Remove and Repair the Gearmotor D  After replacing parts as required   if any   Assembly  reassemble the gearcase  The two smaller gears   Assuming that the procedures through removal of and the oil should be in the lower case  the output  the water seal have been performed   gear will be with the cover  As you lower the cover    1  Remove the electrical wires from the gear drive    motor     2  Unscrew the 4 cap screws holding the  gearmotor to the gearmotor plate     3  Remove the gearmotor from the ice maker     To Inspect the gearmotor    A  Remove the cap screws  holding the gearmotor case  halves together and pry the  two cases apart    B  To lift off the cover  lift up  until you can feel in
22. leading to a liquid  line valve  When the  individual ice level    sensor causes the circuit E  board to energize the m HAND VALV  liquid line valve  the    valve opens  allowing S  D    the liquid refrigerant to LIQUID LINE  P VALVE AD    enter that expansion  THERMO VALVE                                         valve  The thermostatic  expansion valve meters  the liquid refrigerant into                SUCTION LINE  EPR VALVE    August 1994  Page 13    FM2400RH    the evaporator  where it  boils off  evaporates   and absorbs heat  It  then moves through the  ball valve and into the  evaporator pressure  regulator valve  or EPR   The EPR keeps the  evaporator pressure  above a predetermined  point  even though the  suction line pressure of  the remote high side  system may vary  The  refrigerant  now a low  pressure gas  moves  into the suction line of  the remote high side  system     FM2400RH   MAINTENANCE AND CLEANING  ITT  A Scotsman Ice System represents a sizable investment of time and money in any company   s    business  In order to receive the best return for that investment  it MUST receive periodic    maintenance     It is the USER   S RESPONSIBILITY to see that the unit is properly maintained  It is always  preferable  and less costly in the long run  to avoid possible down time by keeping it clean   adjusting it as needed  and by replacing worn parts before they can cause failure  The following  is a list of recommended maintenance that will help keep the machine
23. ore cleaning solution  to maintain a full reservoir    10  After all of the cleaning solution has been  added to the reservoir  and the reservoir is nearly  empty  switch the master switch to OFF    11  After draining the reservoir  as in step 6  wash  and rinse the water reservoir    12  Remove the block from the float in the water  reservoir    13  Switch the master switch to ON   14  Continue ice making for at least 15 minutes  to  flush out any cleaning solution  Check ice for acid  taste   continue icemaking until ice tastes sweet   UHN ARNINGITTT IH  DO NOT USE any ice produced from the  cleaning solution    Be sure no ice remains in the bin   LLL   15  Remove all ice from the storage bin    16  Add warm water to the ice storage bin and  thoroughly wash and rinse all surfaces within the  bin    17  Sanitize the bin interior with an approved  sanitizer using the directions for that sanitizer    18  Replace the front panel     August 1994  Page 14    FM2400RH  MAINTENANCE    MM TLINNARNINGITL TIL  Disconnect electrical power before beginning   MT          1  The bin control uses devices that sense light  PEEL z  therefore they must be kept clean enough so that CONTROLS OUT  they can  see   At least twice a year  remove the OF CHUTE   bin control sensors from the base of the ice chute  Pa    and wipe the inside clean  as illustrated    2  The ice machine senses water level by a probe  located in the water reservoir  At least twice a  year  the probe should be removed from 
24. rt until the reset switch on the circuit board is pressed     E  Check the water level in the reservoir  The machine will not run if there is not enough water in the  reservoir     1  Restore adjust water level  See the next step     August 1994  Page 17    FM2400RH  SERVICE DIAGNOSIS  Condition   No Ice Being Produced    STATUS  NOTHING OPERATES    F  Check  The gear motor  if it will not run  the liquid line valve will not open  If no power to it   Check  The indicator lights on the circuit board  the bin empty light should be ON  the no water light  should be OFF    1  Ifthe bin empty and no water lights are off  check the transformer   a  Transformer  load  side should have 12 to 15 volts  If not  check the  line  side  The line  side should have between 208 230 volts  If the line side has the correct voltage and the  load side does not  replace the transformer   2  If the transformer is good  and the bin empty light is OFF  check the ice level sensors   a  Remove sensors by sliding them sideways out of the ice chute  Visually inspect them   clean if needed   b  Look through the ice chute  eye  hole for something blocking the ice chute   c  If the unit still does not run  replace the ice level sensors   d  If the bin empty light is still OFF  check the circuit board   1  Unplug  opto trans  and  LED  connectors from the circuit board   2  Plug  opto trans  and  LED  connectors from the Scotsman Electronic Control  Testor Model NM1 into the circiut board   a Move the  bin 
25. ternal  contact  then pull the cover  towards the output gear end   and then lift the cover  with  drive motor attached  up and  away from the gear motor  case     Note  The case cover output  gear  bearings  and shaft are  One pressed together  assembly  Replace as a unit   C  Inspect the oil  gears  and  bearings  If the oil level and  condition is acceptable   quickly check the gears and  bearings  They are likely to  be fine if the oil is    If there is evidence of water  in the oil  rusty bearings and  gears  the oil having a  creamy white appearance  oil  level too high  carefully  inspect the bearings and  gears  If in doubt about the  condition of a part  replace it   The oil quantity is 14 fluid  ounces  do not overfill    Note  The gears and  bearings are available only  as pressed together sets     onto the lower case  cover will have to be moved  closer to the second gear after the output gear has  cleared the second gear top bearing    E  After the case is together  and the locating pins  are secure in both ends  replace all cap screws    4  Bench test the gearmotor  check for oil leaks   noise  and amp draw           DS  _ BEARING                   August 1994  Page 25    FM2400RH  CIRCUIT BOARD TESTING    MTT TTNNERNNGI LLII    These procedures require the machine to be connected to the power supply  The voltages of the  electronic circuit are very low  but HIGHER VOLTAGES ARE PRESENT IN THE UNIT  Do not    touch anything but the tester while the unit is being 
26. the    CLEAN THE ICE  LEVEL CONTROL  SENSORS    4  Check and tighten all bolts and screws         CLEAN THE  WATER LEVEL  SENSOR  MATTE  CAUTION  THE  TIMP IS MADE OF  GLASS  ICE SWEEP  MTT  SPANNER WRENCH   only needed on  units mfg  before  reservoir  and the tip wiped clean of mineral 1991   buildup     3  The bearing in the breaker should also be  checked at least two times per year     Check the bearing by     removing the ice chute cover         unscrewing the ice sweep     removing the water shed     using a spanner wrench and unscrewing the   breaker cover     unscrewing the auger stud  Inspect the assembly  looking for wear   See Removal and Replacement to replace bearing  or seals  Reverse to reassemble     August 1994  Page 15    FM2400RH  CLEANING    In some installations the water supply to the  icemaker will be so concentrated with dissolved  minerals   such as calcium carbonate  that as ice  is made  the evaporator and auger become  coated with the minerals  requiring a more frequent  cleaning than twice per year  If in doubt about the  condition of the evaporator and auger  the auger  can be removed so the parts can be inspected   Note  Water filters can filter out suspended solids   but not dissolved solids   Soft  water may not be  the complete answer  Check with a water  treatment specialist regarding water treatment     ALLEN HEAD  DIVIDER  AUGER SCREWS  AND SLOTED      COLLAR       Switch off electrical power  and shut off the  water suplly    For more in
27. wer  Waiter flows from the water reservoir  and the float    drops  letting in more water     4  Open the hand valves  in the liquid lines     8  With both sides operating  the sight glass  should remain full  and the low side pressure will  be about 30 psig    or   4 psig  Gearmotor amp  draw should not exceed the nameplate rating     5  Open the ball valves  in the suction lines      6  Switch on one master switch  and observe     The liquid line valve opens 9  Check the system very carefully for any  The gearmotor runs refrigerant leaks  repair as needed   Within a short time  that side of the machine  begins to make ice   Water flows from the water reservoir  and the float  drops  letting in more water     August 1994  Page 7    FM2400RH  COMPONENT IDENTIFICATION    Liquid line valve s    These valves operate to turn the ice making  process on and off    When the ice level drops in the ice chute  the ice  level sensor will cause the circuit board to close  the liquid line relay  which energizes the liquid line  valve for that side of the system  The liquid line  valve opens  and liquid refrigerant flows to the  thermostatic expansion valve    Thermostatic Expansion Valve   The metering device of each system  the valve s   sense the temperature of the suction line and vary  the amount of liquid refrigerant that passes  through the valve into the evaporator  thus  maintaining a constant level of refrigeration  TXV   s  are factory set  Do not adjust unnecessarily    DO NOT 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Téléchargez le dossier de presse de la semaine d`informations sur  CLS User Manual Description  ORTHOLIGHT Montage- und Bedienungsanleitung  mGUARD - Software de visualización para Mac OS  Manual de Usuario  MANUAL DE INSTALACIÓN USO Y  Epson LW-700 Quick Start and Warranty  Samsung Vaskemaskine 6 kg WF0602NXWG Brugervejledning  Polycom® SoundStation2W™  OxiSelect™ Hydrogen Peroxide Assay Kit    Copyright © All rights reserved. 