        TSPA Manual - Aqua Spa Pak
         Contents
1.     30     Spa Not Heating  Flow Chart       If the soa seems to not be heating the water   follow this troubleshooting flow chart to identify the source of the problem           yes md     v     Hi Are there any error        messages  FLO  FLC  etc    Refer to appearing on the top Make sure the  the error side display  temp  set point  message is higher than the  specific actual water temp     section     ys      lt Q     m    Is the heater on icon appearing  on the top side control display     ys     lt Q  v  ys      lt Q     m  Can you read Measure the water temp   240 vac between and compare it with    the two terminals temp  value displayed  of the heater on the top side control  E    ystem  AS Is the difference works fine   greater than  2  F        Check iftemp  probe    is touching water or    ea if hot air coming from    the back is affecting    Replace its reading  U se foam  the board  to isolate the back of  the probe     rys   lt x        no E    Are the      Replace  ree bites temp  probe  rope with spare   to the         element   w    es            no  4 line  Try to aaa the wires the boar  to the board  amp  the element  m    Still not heating        the element     31 TSPA Power Spa Packs Service M anual    EE spa ls Not Heating     If the spa seems to not be heating the water   perform the following tests to correct the problem        le Verify if there is an error message displayed on the top side control   If it is the case  refer to the specific section 
2.    3   Start decreasing the pressure switch The process to adjust the pressure  setting by turning the adjustment switch remains the same except that  screw counter clock wise very slowly eo have to decrease the setting  until the FLO message disappears  alf a turn at the time    Then  decrease another 1 4 of turn  more  le ee the setting by half a  urn    4   Run the pump in nigh speed for 30  seconds  you should not see an FLO 2   Press any key and wait for 5  message  seconds    5e Turn the pump off and wait 30 seconds  Ifthe silt is too high  an FLO  You should not see an FLC message  message will appear and the   pump will be turned off    6  Run the pump in low speed for 30        seconds  You should not see an FLO 3   Continue the operation until  message  the FLO message does not   reappear    7  Ifyou see an FLO or an FLC message     restart the adjustment procedure     If you are not able to adjust the  pressure switch  change it        TSPA Power Spa Packs Service M anual    Parts List                       Ref   Part Number Description Retail US Cdn  1 282AD0064 P25 Screws for bonding lug  package of 25  spay 7 59  2 210EA0183 P10 Bonding lugs  package of 10  8 02 10 91  3 282AE0022 P10 Screws for mounting feet  package of 10  8 47 11 51  4 250AB0036 P25 Grommets for cable opening  package of 10  5 46 1 42  5 9920 400150 J amp J mini connector for pump 1 7 26 9 88  5 9920 400152 J amp J mini connector for pump 2  single speed 6 68 9 09  5 9920 400150 J amp J mini 
3.    TSPA Power Spa Packs Service M anual    ee GC Trips     If everything is connected and nothing seems to work  there is probably a  problem with the power supply  Perform the following tests to identify and    correct the problem        Note that in new installations  GFCI trippings due to miss wiring are very common   If the breaker is wired properly  GFCI trippings can be caused when the total amount of current    drawn by the spa exceeds the rating of t    e breaker  Such an occurrence is very unlikely since    each output of the spa pack is individually fused and fuses will blow before the GFCI trips     A current leak to the ground will also make the GFCI trip  If one of the components is faulty  and there is a leak of more than 5mA  the GFCI will trip to prevent electrocution     There are different models of GFCI used on the market  Note that our illustrations are generic                     From electrical box To spa  le Verify ifthe GFCI is properly  connected   GH Important  A connections    gt  Neutral of the GFCI    must be connected  to the neutral bus     Neutral from the spa  must be connect  to the breaker     From electrical box    To spa    2   Ifitis not  verify the GFCI wiring  diagram and reconnect it                    3   Ifthe GFCI is properly connected but  still tripping  unplug all outputs  including the two wires of the heater   amp  the light cord        Ifthe GFCI still trips  replace the  transformer     If it stops tripping  reconnect one  co
4.   properly  refer to the pump  section of this manual  4    Verify if the pressure switch cable is  properly connected to the pressure  3   Make sure to clean the filter switch and the board    and to look for air locks  closed   trap valves or anything that could   limit the flow of water        TSPA Power Spa Packs Service M anual 12    FLO Error Message A                      50   4e Turn all pumps off  7   Ifthe FLC message does not  For systems with a circulation pump  appear on the display  the  the circulation pump parameter problem could be either  should be set to 1  not 2  for the with the switch cable or  following test  the board    5   Ifthe problem has not been solved  Remove the plastic cover  lower the set point to 60   by pressing and replace the cable   on the down arrow key  Then short  the two terminals of the pressure 8   Replace the board ifthe FLO  switch with the jumper cable  error message is still displayed   on the top side control    6  An FLC message should appear on  Refer to the  How to replace  the display  the board  section    The FLC message identifies the  pressure switch as the source of  the problem   If the installation is older than 2 years   replace the pressure switch an  recalibrate it   If the installation is recent  try to  readjust the pressure switch  If it is  not possible  replace the switch    Refer to the  H ow to adjust the  pressure switch  section of this  manual    13 TSPA Power Spa Packs Service M anual    TSPA Power Spa
5.  194 79  27 530AA0035 3 5 5Kw in line heater 176 14 239 55  27 530AA0025 3  4 5Kw in line heater 176 14 239 55  27 530AB0087 5 5Kw element for in line heater 88 23 119 99  27 530AB0074 4 5Kw element for in line heater 88 23 119 99  28 9917 100187 TSPA 1 plastic cover 30 48 41 45  29  282AB0136 P25 Screws to hold the plastic cover  package of 25  4 46 6 06  30 9917 100124 W hite metal cover 33 37 45 39  30 9917 100172 Black metal cover 33 37 45 39  31 EQGX165 Board for TSPA 1 P122 P222 01 LS H 34 5 JJM CC 329 78 448 50  31 EQGX214 Board for TSPA 1 P122 P222 B1 O 1 LS LW H5 5 AMP OM 358 96 488 19  31 EQGX219 Board for TSPA 1 P122 P222 B1 0 1 L2S LW H35 5 JJM BF 359 01 488 25   9920 400125 10 foot temperature probe 19 21 26 12   9920 400245 25 foot temperature probe 23 88 32 48    A       TIT TRESESESELELEEEE EE       a       4 S   re  URL LF   F    o      d       Prices subject to change without prior notice        TSPA Power Spa Packs Service M anual       Wiring Diagram                                                                                                                                                      CIRCULATION a J  PUMP g fat  g      BLOWER 2      z a  g  PUMP  2     i H  JIA  PUMP  1 fl n ry  LIT ZN    net Des OE  on   __   AC 3 ej  POWER IN Zz  S  Em    d  aL  TEMPERATURE  SENSOR  PRESSURE  HI LIMIT SWITCH  SENSOR  Pump 1 Ozone Heater  Red P31 Black P21 Black 1 P13  White P32 White P22 Black 2 P14  Black P33 Green P23 Green   Ground Ground  Green P34  Pump
6.  2 Circulation Pump Connectors  Red P27 Black P18 Keypad P1  White P28 White P19 Temp  sensor P4  Black P29 Green P20 Transfo  P12  Green P30 Pressure switch P8  Hi Limit sensor P10  Blower Light Connector  Black P24 Black P15  White P25 White P16  Green P26  TSPA Power Spa Packs Service M anual 62    Professional Repair Kits    All you need in a single case     fa                GECKO    Gecko s professional repair kit contains  all you need to properly service and repair  Gecko s line of power spa packs     e    Top side controls   e Temperature probes   e Pressure switch cables  e Flowswitches      Elements   e Heater wires   e Transformer   e Ground lugs   e Gromets      Standoffs   e Light cords      Strain reliefs for light cord  e Plugs   e Fuse kits   e Screws       Call 1 800 78 GECKO    to order or for more info        TSPA SERVICE MANUAL       COMPLETE  SERVICE GUIDE  WITH STEP BY STEP  INSTRUCTIONS ON     e  GFCI TROUBLESHOOTING  LJ  LOW LEVEL PROGRAMMING  e  UNDERSTANDING   amp  CORRECTING  ERROR MESSAGES  LJ  SYSTEM MALFUNCTIONS  e  PART REPLACEMENT  INSTRUCTIONS     amp  MORE    C    GECKO    1 800 78 GECKO   www gecko electronic com                
7.  Packs Service M anual    14    FLC Flow Chart G    If an FLC message  problem with the pressure switch  pump is off but  water pressure is detected  appears on the top side control display  follow  this troubleshooting flow chart to identify the source of the problem        For packs manufactured before 1 198  you have to press a key after each step to reset the system          yes      lt       _ 0    Disconnect the  pressure switch cable        Does an FLO error message  appear on the top side control  when the pump is working           yes      gt      no na  E intsllation   Replace the  Ba oleae  two years   1      j Replace the    Ape pressure switch   switch       Replace the  board   Replace the  pressure switch  if the FLC  message still  appears on  the display  when you start    or stop the pump     15 TSPA Power Spa Packs Service M anual    Be FLC Error Message    The FLC message is related to the pressure switch   If the system detects any pressure when the pump is off  the message  FLC will appear on the display           For packs manufactured before 1 98  every time the FLC message appears on the display  the  message will remain on until a key  any key  is pressed  You have to press a key between each of  the following corrective steps     Power can remain On when the following steps are performed        Ifthe top side control does not  display the FLO message  remove    1  Disconnect the pressure switch cable  2    If an FLO message appears on the top the pl
8.  or  240 vac for 240 vac  blower key   at the blower    output on  the boar   in high speed   fold  I  F ys      lt  gt      m        i Does the  lower restart    a few minutes   VI  It is possible eine Replace  that the blower the  shut off   does not have blower       sufficient air entry   Replace  In blower low prog   the  change the blower blower  number o pee fuse   to 2     If this change  gill does not  correct the situation   create an opening  to let more air go  under the skirt     41    Replace  the board  if the blower  is still not starting     TSPA Power Spa Packs Service M anual    Blower Does Not Work     If the blower does not work   perform the following tests to correct the problem        To increase the life of the relay  we are using a circuit called snubber on the blower relay   With this type of circuit  if no blower is connected to an output and the relays are open   the voltmeter will still read voltage of around 60 volts  This is normal     It is important to measure voltage when the blower is connected to the pack   Power must remain On     1   Verify the blower low level program   ming parameters are set properly   Code  BL  0  no blower   1  1 speed blower   2  2 speed blower   3  3 speed blower output     S      a       4 3  Ifthe blower on icon does not  appears on the top side control  display  replace the top side control     Blower on  Icon    2   Verify ifthe blower on icon appears  on the top side control display  when you press on the blo
9.  the problem stil  persists     Replace the board if  the problem still  persists     27 TSPA Power Spa Packs Service M anual    o Nothing Works     If everything is connected and nothing seems to work  there is probably a  problem with power supply  Perform the following tests to identify and  correct the problem                 1   On the terminal block  measure the 3   Measure the voltage between  voltage between line 1  black  and line 2  red  and neutral  white    line 2  red   You should get  120 vac     You should get  240 vac        2   Measure the voltage between 4  Ifyou do not get good readings   line 1  black  and neutral  white  there must be a problem with the  You should get  120 vac  electrical wiring     Call an electrician        TSPA Power Spa Packs Service M anual 28    If you are getting good voltage readings but nothing seems to work   perform the following tests to correct the problem           1   Verify ifthe top side control is  properly connected to the board        2   Replace the transformer fuse  if there is still nothing working                 3   If nothing works  clean the pins of  the transformer orange connector   A small coating of film may cause a  bad connection        4e Replace the transformer if the  problem persists     5   Ifthe problem is still not solved   replace the board   Refer to the   How to replace the board  section         29    TSPA Power Spa Packs Service M anual    Nothing Works     TSPA Power Spa Packs Service M anual
10.  thermometer  optional              Required   pack parts   Regulation sensor Transformer  Hi Limit sensor Pressure switch  TSPA system board Fuses   or complete spa pack  Top side control    Gecko Electronic Inc  sells Professionnal Repair Kits that include everything needed for TSPA power spa pack servicing   Go to last page of this manual for more information     ee Electrical Wiring    Proper wiring of the electrical service box  GFCI box and pack terminal  bloc is essential           a       Electrical Box GFCI Pack Terminal Bloc    1   Make a visual inspection for signs of mis wiring   Refer to supplied wiring diagrams   Call an electrician if necessary        TSPA Power Spa Packs Service M anual    GFC Flow Chart Jn    If the GFCI trips     follow this troubleshooting flow chart to identify the source of the problem  e          yes  lt  gt  no       Isthe    GFCI  property va  connected   Verify  the wiring  yes      lt  amp    no diagram  amp   reconnect it   Unplug  everything  including  the two wires  ofthe heater  amp   the light cord   iad GFCI w  Pra aa  still tripping  Reconnect  one component  at the time  BEA until the  Replace GFCI starts  he to trip   transformer  Replace  the defective  component     yes     ee     no    Ifthe    GFClis A    still tripping   There is disconnect Replace  a problem the incoming the GFCI   with the power line   cable     Cal Is me  all an GFCI sti  electrician  tripping     Replace  the board  if the GFCI  is still tripping  
11.  water should be over 35  F to perform the following steps   Press a key after each step to reset the system   Power can remain On     3   Reconnect the probe     If the Prr message is still displayed  on the top side control  replace   E 956KO the probe with a spare and place  Cae its head directly in the spa water        Ifthe problem is solved  replace the    probe   1   Verify if the regulation probe  the 4  Replace the board if the problem has  sensor located in the spa  is pro  not been corrected     perly connected        2   Disconnect the probe connector  and try to clean the probe connector  pins  A small coating of film may  cause a bad connection        TSPA Power Spa Packs Service M anual 18    PrH Flow Chart       If a PrH message  potential problem with the Hi Limit sensor  appears on  the top side control display  follow this troubleshooting flow chart to  identify the source of the problem        Press a key after each step to reset the system     Check if the Hi Limit  probe  the sensor located  in the heater barrel   is properly connected     Unplug the probe connector  and try to clean the pins on  the board  a small coating of film may  cause a bad connection    Reconnect the probe     Replace the probe with  a spare and verify if  the problem is solved     If it is  replace the  probe with the spare     Replace the board if  the problem has not been  corrected     19 TSPA Power Spa Packs Service M anual    ee rh Error Message    The Prh message is relate
12. Circulation Pump Flow Chart       If the circulation pump seems to not be working  follow this  troubleshooting flow chart to identify the source of the problem        Verify that the circulation pump low level prog   is set properly     Increase set point  2   above actual water temp   to start circulation pump            yes      lt  lt      no    Do you  read   20 vac for an  20 vac circ  pump   or  240 vac for 240 vac   at the circ  pump             output on  the board   Replace ae  the circulation eplace  pump  the circulation  pump fuse   Replace  the board     49 TSPA Power Spa Packs Service M anual    Circ  Pump Does Not Work     If the circulation pump does not work   perform the following tests to correct the problem  A       To increase the life of the relay  we are using a circuit called snubber on the circ  pump relay   With this type of circuit  if no circ  pump is connected to an output and the relays are open   the voltmeter will still read voltage of around 60 volts  This is normal     It is important to measure voltage when the circ  pump is connected to the pack   Power must remain On     1   Verify the circ  pump low level program   ming parameters are set properly   Code  CP  0  no circulation pump   1  circulation pump off when water temp  is  2  F higher than set point   2  circulation pump on all the time        e      3   Remove the plastic cover and measure  100 OF      the voltage betw een the black and  ate    white wires of the circulation pump  
13. Is it a new the pressure switch with a jumper  Replace the board   intsllation   less than Does an FLC error Msi  2 appears on the top side  two years   rer control display   Replace  o N the pressure  switch   Adjust  the pressure  switch     11 TSPA Power Spa Packs Service M anual    FLO Error Message    The FLO message is related to the pressure switch   If the system does not detect any pressure when the pump is manually or  automatically turned on  the message FLO will appear on the display        FLO    For packs manufactured before 1198  every time the FLO message appears on the display  the  message will remain on until a key  any key  is pressed  You have to press a key between each of  the following corrective steps     Note that there must be enough water in the spa for it to be used normally  The FLO message can  occur when the spa filter is dirty or when something limits the flow of water in the pipe     For packs manufactured after 7 98  the heater is shut off when an FLO message appears   For packs manufactured in 97 and before  the pump and the heater are shut off when  an FLO message appears     Power can remain On when the following steps are performed     1   Verify the the circulation pump  low level programming parameters  are set properly   Code  CP  0  no circulation pump   1  circulation pump off when  water temp  is 2  F higher than set point  2  circulation pump on all the time        2   Verify if the pump is working   If the pump is not functioning
14. TSPA POWER SPA PACK  SERVICE MANUAL    50       o     Visual step by step guide to easily  identify  amp  correct technical prodlems     men    IS       o    Topics covered in this manual are as follows        Power  amp  ground check  Electrical wiring 4  GFCI 5       Programming  Low level programming 8       Error messages appearing on the top side control display             FLO 11  FLC 15  Prr 17  Prh 19  HL 21  Freeze 25  Troubleshooting  N othing seems to work  27  Water is not being heated  31  Pump 1 or pump 2 does not work  35  Blower does not work  41  Light does not work  44  O zone generator does not work  47  Circulation pump does not work  49  Keys do not work  51  How to  Replace a board 53  Replace a heater 57  Adjust a pressure switch 59  Miscellaneous  Parts list 60  Wiring D iagram 62    Professional Repair Kit Info 63       In order to be as useful as possible  this manual was written in two distinct formats   Problem solving solutions are described with trouble shooting flow charts and    step by step procedures     They should be used together  flow charts giving a global overview of specific  problems while step by step procedures are more detailed        Tools  amp  Parts A    Tools  test equipment and components are necessary to  perform service calls on a TSPA power spa pack           Required tools   Pliers 38  open end wrench  Phillips  amp  flat screwdrivers Jumper cable  11 32  nut driver Multimeter  1 4  open end wrench GFI tester  amp  digital
15. ackage of 5  8 00 10 88  8 530AB0020 P5 Gaskets for 3  heater  package of 5  10 03 13 64  9 530AB0055 N ut for 2  heater 4 90 6 67  9 530AB0013 N ut for 3  heater 5 39 7 33  10 282FB0104 P10 Metal standoffs for triac  package of 10  22 77 30 97  11  282FB0167 P25 Plastic standoffs for the board  package of 25  12 65 17 21  12 9920 400124 P5 Pressure switch cables  package of 5  11 81 16 06  13 282CA0092 P25 Nuts for transformer  package of 25  Uy 10 30  14 510AD0064 Pressure switch 28 43 38 67  15 9920 100020 120 volts transformer 45 59 62 00  15 9920 100050 240 volts transformer 59 59 81 58  16 9920 400123 P5 Heater cables for in line heater  package of 5  10 47 14 24  17 282AD0038 P25 Ground screws  package of 25  9 87 13 42  18 430AC0117 P10 Fuses for light  package of 10  11 14 15 15  19 430AC0054 P10 Fuses for circulation pump  package of 10  10 70 14 55  20 430AC0069 P10 Fuses for blower  package of 10  17 82 24 24  21 430AE0033 P10 Fuses for pump 1 and pump 2  package of 10  54 36 73 93       TSPA Power Spa Packs Service M anual 60    Parts List          Ref   Part Number Description Retail US Cdn  22 430AC0092 P10 Fuses for transformer  package of 10  11 14 15 15  23 282AB0128 P25 Screws for the triac  package of 25  7 68 10 45  24 430AC0054 P10 Fuses for ozone  package of 10  10 70 14 55  25  282AD0072 P25 Screws for the heater cable  package of 25  8 80 11 97  26 9920 400122 High limit sensor for in line heater 13 99 19 03  27 530AA0012 2 5 5Kw in line heater 143 23
16. astic cover and replace the   side control display when the pump is pressure switch cable    started  adjust the pressure switch if it   is anew installation  less than two 3  Replace the board if the FLC   years  or replace the pressure switch  error message is still displayed    Refer to the  How to adjust the on the top side control    pressure switch  section of this  Refer to the  How to replace   manual  the board  section of this  manual        TSPA Power Spa Packs Service M anual 16       Prr Flow Chart    If a Prr message  potential problem with the regulation sensor  appears on  the top side control display  follow this troubleshooting flow chart to  identify the source of the problem        Press a key after each step to reset the system     N ote that the water temperature  must be over 35  F to operate the spa     Check if the regulation  probe is properly connected     Unplug the probe connector  and try to clean the pins on  the board  a small coating of film may  cause a bad connection    Reconnect the probe     Replace the probe with  a spare and verify if  the problem is solved     If it is  replace the  probe with spare     Replace the board if  the problem has not been  corrected     17 TSPA Power Spa Packs Service M anual    ee Pre Error Message    The Prr message is related to problems with the regulation sensor   The system is constantly verifying if the reading of the temperature probe  is within normal limits           Note that the temperature of the
17. barrel feels hot c   If it is hot  verify if something is   obstructing the flow of water    closed valves or dirty filter   d     b  Ifit is not  verify if the Hi Limit probe  is properly connected    lt  3   F      a        O       i    Ti    na 4           Try to clean the probe connector  pins  A small coating of flm may  cause a bad connection     Reconnect the probe     Ifthe HL message is still appearing on  the display  replace the probe     Ifthe problem is not solved  replace  the board   Refer to the  How to  replace the board  section of this  manual     If the reading is at or higher than 19  F    Go to next page if the top side display  shows the right temperature     Go to page 24 if the display does  not show the right temperature        TSPA Power Spa Packs Service M anual    22    HL Error Message  in    If a digital thermometer reading of the water temperature is at or higher  than 119  F and the display of the top side control shows the right tempe   rature  perform the following tests            If the weather is very warm  4  Ifyou do not read 240 vac  the pump  may be overheating the water during  le Take off the spa cover  even during the filtration cycle   the night   Start the blower if the spa  is equipped with one  Wait until the    spa cools down  Add cold water if    necessary   tE        If the weather is not a factor     ie  N Enter the programming  i mode and lower the filtration cycle    duration       5e If you do read 240 vac  replace  the 
18. ber box control    2   First replace the bulb of    the spa light   5   Ifthe light on icon is displayed    but the light still does not work   remove the plastic cover and measure  38 oh the voltage between the two wires of  2 the light at high intensity  P15  amp  P16       connectors on the board     Light on If you have  12 vac  replace the  Icon light socket  3  If the light is still not working  FROM  verify if the light on icon appears  on the top side ore ey         when you press on the light key        A  4   Ifthe light on icon is not turned        l      I  on  use a spare top side control to   haO i    verify if the keypad is defective   If it is  replace the keypad  6    Ifyou do not read any voltage   replace the light fuse on the board   If not  replace the board     7    Ifthe problem persists  replace the  board   Refer to the  H ow to replace  the board  section         TSPA Power Spa Packs Service M anual 46       Qzonatator Flow Chart    If the ozonator does not work   follow this troubleshooting flow chart to identify the source of the problem        Verify that the ozone low level prog   is set properly     yes      lt Q     m  T Is the                yes      lt a  no    filtration     kon appearing    i p    Bes on the display  Stert  read a filtration cycle   220 vac for an The filtration cycle  20 vac ozonator icon should appear   or 240 vac for 240 vac  on the display   on the board   Replace Replace  the the  ozonator  ozonator  fuse   Replace  th
19. board   Refer to the  How to  2   Lower the set replace the board  section of this  point below the actual manual      temperature of the water     The heater on icon on the top side  control display should disappear        3   Remove the spa cover   With a voltmeter  read the voltage  between the two heater wires on  the board        23 TSPA Power Spa Packs Service M anual    tl Error Message    If a digital thermometer reading of the water temperature is at or higher  than 119  F and the display of the top side control does not show the right  temperature  perform the following tests        1   Verify ifthe temperature probe  is in contact with water and if  cold air coming from the back  can affect its readings     Use foam to isolate the probe  from cold air if it is the source  of the problem        2   Verify ifthe temperature probe  is properly connected     If it is  replace the probe     3   Replace the board ifthe HL error  message still appears on the display    Refer to the  How to replace the  board  section of this manual          TSPA Power Spa Packs Service M anual 24    Freeze Flow Chart    If a FrEE message appears on the top side control display   follow this troubleshooting flow chart to identify the source of the problem                               yws     lt   amp   Is the water temperature  of the spa lower than  the desired temperature   mys   lt  amp    amp   v  Do you  read n vac  to the  heater  UA  Refer to   Spa not heating   section     The sys
20. connector for pump 2  two speeds 7 26 9 88  5 9920 400148 J amp J mini connector for ozone 5 93 8 06  5 9920 400147 J amp J mini connector for blower 5 93 8 06  5 9920 400154 AMP connector for pump 1 7 26 9 88  5 9920 400169 AMP connector for pump 2  single speed 6 68 9 09  5 9920 400154 AMP connector for pump 2  two speeds 7 26 9 88  5 9920 400153 AMP connector for ozone 5 93 8 06  5 9920 400153 AMP connector for blower 5 93 8 06  5 9920 400169 AMP connector for circulation pump 6 68 9 09  5 9920 400165  amp  regular connector for pump 1 7 26 9 88  5 9920 400163  amp  regular connector for pump 2  single speed 6 68 9 09  5 9920 400165  amp  regular connector for pump 2  two speeds 7 26 9 88  5 9920 400162  amp  regular connector for ozone 5 93 8 06  5 9920 400161  amp  regular connector for blower 5 93 8 06  5 9920 400164  amp  regular connector for circulation pump 5 93 8 06  5 9920 400155 AMP connector for light  option LA  3 35 4 45  5 9920 400178 Light cord  option LS  IL 10 30  6 140AA0125 P10 Blank plate for J amp J mini and AMP  package of 10  10 90 14 82  6 140AA0133 P10 Blank plate for J amp  regular  package of 10  15 15 20 60  7 9917 100125 Left foot for 2  heater 13 37 18 18  7 9917 100126 Right foot for 2  heater 13 37 18 18  7 9917 100189 Left foot for 3  heater 13 37 18 18  7 9917 100188 Right foot for 3  heater 13 37 18 18  8 530AB0061 Tail pieces for 2  heater 5 39 7 33  8 530AB0039 Tail pieces for 3  heater 6 24 8 48  8 530AB0042 P5 Gaskets for 2  heater  p
21. d to problems with the H i Limit sensor   The system is constantly verifying if the reading of the Hi Limit sensor  is within normal limits           f MN       Gj  G         i  i     lt   w       U D       Press a key after each step to reset the system   Power can remain On     3   Reconnect the probe     If the Prh message is still displayed  on the top side control  replace  the probe with a spare and verify  if the problem is solved        1   Remove the plastic cover and 4e Replace the board if the problem  verify ifthe hi limit probe  the has not been corrected   sensor located in the heater  barrel  is properly connected        2   Disconnect the probe connector  and try to clean the probe con   nector pins  A small coating of film  may cause a bad connection        TSPA Power Spa Packs Service M anual 20       HL Flow Chart    If an HL message  potential problem with the Hi Limit sensor  appears on  the top side control display  follow this troubleshooting flow chart to  identify the source of the problem                                             Press a key after each step to reset the system   yes      lt  amp      o       _  Measure the temperature  of the water with a digital thermometer              yes      lt  gt  no Is the water temperature  i at or higher than 19  F   Do you read the right  water temp  on the display     EN  Verify ifthe mz  ys      lt  gt   m temperature probe  is touching the water Verify ifthe  Is the weather or if cold air from the tem
22. e board  ifyou  still have  no  voltage     47 TSPA Power Spa Packs Service M anual    Qzonator Does Not Work     If the ozonator does not work     perform the following tests to correct the problem                      To increase the life of the relay  we are using a circuit called snubber on the ozonator relay   With this type of circuit  if no ozonator is connected to an output and the relays are open   the voltmeter will still read voltage of around 60 volts  This is normal   It is important to measure voltage when the ozonator is connected to the pack   Power must remain On   1   Verify ifthe ozone low level program   ming parameters are set properly   Code  03    0  no ozone lamp     1  ozone activated during filter cycle       2  ozone output always on   E    3   Measure the voltage at the  98 ozonator outputs   P21  amp  P22  connectors on the board      VY You should read    120 vac for an 120 vac ozonator  Fiter cycle on  240 vac for an 240 vac ozonator   Icon  4  Replace the ozonator if you have  2   Verify ifthe filter cycle on icon good voltage   appears on the top side control Sacra   display  If not  start a filtration cycle  fuse  Refer to the user manual for 3 ol  information on how to start E    a filter cycle E 1 I  3 i  3    3 Ji  5   Replace the ozonator fuse if you  do not measure sufficient voltage   6   Replace the board if you still have  not any voltage   Refer to the   How to replace the board  section    TSPA Power Spa Packs Service M anual 48    
23. eshooting flow chart to identify the source of the problem        Verify that the light low level prog   is set properly     ys      lt  gt      mv  F  Did you    try to es      lt    no  replace 7                   the spa  light bulb  Try to   ERE  the lig  bub  VA      yes      gt    no Is the  li ht  still not  Does the   hg   light on icon  i ere  aperin Reps    the top side  top side control  control    display    when you  press on  the spa light  key  If it still does not  work  replace the board    ys      lt Q     m      oa    read Rvac  on the light  Replace output Replace the spa  the spa on the light fuse   light socket  board   in high    intensity      Replace the board    if the light is still not working     45 TSPA Power Spa Packs Service M anual    o Spa Light Does Not Work     If the spa light does not work   perform the following tests to correct the problem                              To increase the life of the relay  we are using a circuit called snubber on the light relay   With this type of circuit  if no light is connected to an output and the relays are open   the voltmeter will still read voltage of around 2 volts  This is normal   It is important to measure voltage when the light is connected to the pack   Power must remain On   1   Verify if the light low level program   ming parameters are set pro perly   Code  LI    0  no light  pa  1  12 volts O n O ff     2  12 volts 3 intensities     3  120 volts  circulation pump output     4  Internal fi
24. ide control display  when the pump 2 key Is pressed   verify if Pump 2 works in one of  the speeds        TSPA Power Spa Packs Service M anual    38    Pump 2 Does Not Work     If Pump 2 does not work in both speeds   perform the following tests to correct the problem               Pump 2 fuse  1   If Pump 2 still does not work 3   Turn Pump 2 to low speed  in both speeds  replace the pump 2 and measure the voltage between  fuse  the white and the red wires  connector  P27  amp  P28 connectors  on the board    2   If replacing the fuse is not effective or if The reading should be  240 vac     Pump 2 works in only one of two  speeds  read the voltage on the board  for both speeds  4    Ifthe voltage is as it should be   replace Pump 2     5   If not  replace the board        Turn Pump 2 to high speed and  measure the voltage between the white  and the black wires connector  P28  amp   P29 connectors on the board      The reading shoud be  240 vac        39 TSPA Power Spa Packs Service M anual    TSPA Power Spa Packs Service M anual    40    If the blower does not work     Blower Flow Chart       follow this troubleshooting flow chart to identify the source of the problem                  Verify that the blower low level prog   is set properly      i yes      gt         no    i Is the      yes      gt    no     ower on  4 icon appearing m  on the display  Do you of the top side Replace  read control the top   220 vac for an when you side control   20 vac blower press on the    
25. mponent at the time until the  GFCI starts to trip  Replace the  defective component        TSPA Power Spa Packs Service M anual    GF Trips  MN    If the GFCI still trips even after the replacement of the transformer   perform the following tests to correct the problem              1   Disconnect the incoming power  lines     If the G FCI still aps there must  be aproblem with the cable   Call an electrician     2   Ifthe GFCI stops tripping   Replace the GFCI     3   Ifthe GFCI trips again   replace the board   Refer to  the  How to replace the board   section of this manual         7 TSPA Power Spa Packs Service M anual    o Lov Level Programming    Unique feature that allows the spa manufacturer to configure the spa  pack to their own needs        The configuration is programmed from the keypad and is stored into a permanent  memory  Most of the time  the user does not have access to this memory   However  ifthe configuration has not been set properly or if the end user has  accessed the configuration menu by mistake  it is possible that the system will not  function normally because wrong parameters have been entered     Enter Key    We suggest that you    review the configuration  of the low level program   3     ming every time you visit    a customer     im MM Specific settings are  supplied by the spa  manufacturer        Up and Down Arrow Keys Program Key    P11 Pill         Parameter Value    To access low level programming  the programmer must press the program ke
26. nclosure and slide the  heater from under the pack     5e Loosen the two  screws that hold        the mounting feet  on each side ofthe  pack  8    Slide the  heater out        9    e       Slide the new heater into place and  attach it to the enclosure using the  two nuts     The two nuts must be well tightened  because they are also used as a current  collector in case of heater failure     Unscrew the two wing nuts that hold  the plate to the heater and slide the  Hi Limit temp  sensor under the plate  and into the heater     Screw the two wing nuts just enough  to hold the sensor in place     Connect the two wires from the board  to the heater     It is important to hold both nuts of the  element when tightening  If you bend  or twist the end of the element  you  may damage it     Check if the two wires for the element  are well connected to the board     10   Reinstall the pressure switch and recon     nect its cables  in no particular order         TSPA Power Spa Packs Service M anual    58    How To Adjust a Pressure Switch ee       C  l         18    For systems manufactured For systems manufactured   since VV98  prior to 17 98    1   Turn the pump  or the circulation These systems are programmed with  pump  in low speed  software that shuts the pump off    every time an FLO message occurs   2   Increase the setting of the pressure    switch to 4 PSI  or until you have In this case  you have to press a key  an FLO message on the display   any key  to reset the system 
27. och  P18  amp  P19 connectors on the  LE board    The reading should be  aera  240 vac    120 vac for a 120 vac  on pump   Circ  pump fuse  2   Start the circulation pump by  increasing temp  set point to  2   higher than the actual water  temp            0ULCOO DCO ee Dg        4    If you do not read any voltage   replace the circ  pump fuse on  the board     5    If the problem persists  replace the  board   Refer to the  How to replace  the board  section         TSPA Power Spa Packs Service M anual 50    Keys Flow Chart o    If one of the keys of the top side control display seems to not be working   follow this troubleshooting flow chart to identify the source of the problem        Unplug the top side  control and  replace with spare  keypad           yes      lt  gt      no    Are the  keys working              Replace Replace  the keypad  the board     51 TSPA Power Spa Packs Service M anual    o Keys Don t Work      If the one of the keys seems to not be working  perform the following tests  to correct the problem                1    Replace the top side control  with a spare keypad     2  3  4         Check ifthe keys are responding     e    If they are  replace the keypad     e    If they are not responding   replace the board        TSPA Power Spa Packs Service M anual    52    How To Replace The Board    If the board of a TSPA pack has to be replaced   make sure to turn the power off           1   Remove the pack cover and 3  Unscrew the plastic cover   disconnec
28. of circuit  if no pump is connected to an output and the relays are open   the voltmeter will still read voltage of around 60 volts  This is normal     It is important to measure voltage when Pump 1 is connected to the pack     Power must remain On     le Verify if there is an error message  displayed on the top side control   If it is the case  refer to the specific  section of the error message     2   Verify if Pump 1 low level  programming parameters  are set properly   Code  P1  1  single speed pump   2  two speed pump     58   amp  4  Pump 1 on icon      3   Verify if Pump 1 on icon appears  on the top side control display  ee you press on the pump  ey        4   fit does not appear  use your spare  top side control to verify ifthe keypad  is defective     If it is  replace the keypad     If not  replace the board     5e If Pump 1 icon appears on  the top side control display  when the pump 1 as pressed   verify if Pump 1 works in one ofthe    speeds        TSPA Power Spa Packs Service M anual    36    Pump 1 Does Not Work     If Pump 1 does not work in any speed   perform the following tests to correct the problem               Pump 1 fuse  1   If Pump 1 does not work in either 3   Turn Pump 1 to low speed  speeds  replace the pump 1 fuse  and measure the voltage between  the white ac n a we      t  2   If replacing the fuse is not effective or if RR SEPA peaa  Pump 1 works in one of two speeds   read the voltage on the board for both The reading should be  240 vac   s
29. of the error message     ne Os    a         2   Ifitis not  verify if you can call for heat 4    If the icon is not appearing on the display     by increasing the temperature set point  with a digital thermometer  measure  Press on the Up Arrow key to increase the water temperature and compare  the temperature set point  your reading with the temperature    value displayed on the top side control     If the values are different  42  F   check  if the sensor is touching the water or if  hot air from the back is affecting its   a ee     readings     ts ve O E  Set point   Heater on  icon icon    3   Verify ifthe heater on icon appears  on the top side control display           The icon will be on when the  heater is working  It will flash if there    is a call for heat but the heater has 5   lIfso  use foam to isolate the back of  not started yet  the probe     6   If not  replace the temperature sensor  with a spare one     7    If the spa is still not heating  replace  the board        TSPA Power Spa Packs Service M anual 32    Spa Is Not Heating  i    If the heater on icon appears and the spa is still not heating  perform the  following tests to correct the problem                                Qa  o  i  a       gt   wiht  D oo 2  1   Remove the plastic cover and measure  the voltage between the two heater  screws on the board  2  If voltage reading is good  verify    ifthe heater wires are proper    Replace the board if you are connected to the element  y    not getting a 
30. peeds    120 vac for a 120 vac pump     4    If the voltage is as it should be   replace pump 1     5   If not  replace the board        Turn Pump 1 to high speed and  measure the voltage between the white  and the black wire connectors  P32  amp   P33 connectors on the board      The reading shoud be  240 vac     120 vac for a 120 vac pump        37 TSPA Power Spa Packs Service M anual    o Pump 2 Does Not Work     If Pump 2 does not work   perform the following tests to correct the problem        To increase the life of the relay  we are using a circuit called snubber on the pump relay   With this type of circuit  if no pump is connected to an output and the relays are open   the voltmeter will still read voltage of around 60 volts  This is normal     It is important to measure voltage when Pump 2 is connected to the pack   Power must remain On     le Verify if there is an error message  displayed on the top side control   If it is the case  refer to the specific    section of the error message     2    Verify the pump 2 low level  programming parameters  are set properly    Code  P2   1  single speed pump    2  two speed pump     96    e     Pump 2 on icon J    3   Verify if Pump 2 on icon appears  on the top side control display  ie you press on the pump  ey     de    De       If it does not appear  use your spare  top side control to verify if the keypad  is defective     If it is  replace the keypad     If not  replace the board     If Pump 2 icon appears on   the top s
31. perature probe  TE very warm  back can affect its is properly connected   reading   Take off If so  replace  the spa cover oe ad     v the probe   Even during Lower the set point  hengi  IN beow teaid  MA    Start the Replace SON ng   The pump is    blower if the overheating the Replace the  the spa is board  The heater on water during board if the  se icon on the display the filtration HL error  win one  of the top side control cycle  message stil  W ait until should disappear  L  Werthe appears   e spa Do you read filtration cycle  oe OM n 240 vac between the duration     i o two heater wires  WALI on the board   necessary    yes         no  m   i  When the HL    J message appears  F  _   Tak l does the heater on  Verify if something barrel feel hot  Verify if the HL probe  is obstructing the is properly connected   on orne water I Try to acan the  closed traps or pins an  dirty filters   E reconnect it  If the HL message is still  appearing on the display  replace the probe   l  Ifthe HL message is still appearing on the display   replace the board   21    TSPA Power Spa Packs Service M anual    tL Error Message    The HL message is related to the Hi Limit sensor  It will appear  on the display whenever water temperature at the hi limit sensor    exceeds 119  F        Press a key between each step to reset the system   Power can remain On     l   Measure the temperature of the  water with a digital thermometer     2    If the reading is below 19  F    a Check ifthe heater 
32. reading of  240 vac   If not  tighten the wires to the board  and the element     3   Ifthe problem has not been  solved  replace the element        33 TSPA Power Spa Packs Service M anual    TSPA Power Spa Packs Service M anual    34       If Pump 1 or Pump 2 does not work     Pump Flow Chart    follow this troubleshooting flow chart to identify the source of the problem                                   yes D gt      v  Are there any error  Hi messages  FLO  FLC  etc    appearing ay top  ae E  APA side display   the error  dra  specific     vs  lt W no  section  4    Is the pump lor 2  icon appearing    on the top Verify that Pump 1  amp   se omrol Pump 2 low level prog   i isplay are set properly   wnen you press ae If they are  replace the  the pump lor pump 2 key  top side control   Replace the  top side control            yes        lt Q     v    Is the pump working  on one or both speeds  If it still does  not work  replace  the board   yes      lt  gt   v J  p Replace pump 1    or pump 2 fuse  Hi  Pump s  still not working   yes      lt Q     m  Measure the voltage  on the board for both speeds  of pump lor pump 2   Do you read 240 vac  Hi for both speeds  1  Replace pump 1 Replace  or pump 2  the board   35    TSPA Power Spa Packs Service M anual    o Pump 1 Does Not Work     If Pump 1 does not work     perform the following tests to correct the problem        To increase the life of the relay  we are using a circuit called snubber on the pump relay   With this type 
33. res to  the board  A wiring diagram is  ee on the back of the power   ox cover and indicates where the  wires must be connected     18    Connect the heater cable     19    Reinstall the transformer and  connect it to the board     20   Connect the pressure switch and  the high temperature sensor  cables     21   Verify all the connections   Reinstall the plastic cover   Place its bottom part first     22   Connect the keypad and the  temperature sensor     23   Connect the power cable and  turn the power on        TSPA Power Spa Packs Service M anual    56    How To Replace The Heater o    Follow this procedure if the heater of a TSPA pack has to be replaced   M ake sure that the power to the pack has been turned off            Heater H eater Heating Pressure Heater  Nut Wing Nuts Element Switch Nut   amp  Plate Nuts       Before starting the removal procedure   e Disconnect the power input cables of the pack     Make sure that the water valves of the spa are closed       1   Disconnect the two connectors on 2   Unscrew the two wing nuts that hold  the top of the pressure switch and the plate of the heater and remove  unscrew and remove the pressure the Hi Limit temperature sensor  switch  from under the plate        57 TSPA Power Spa Packs Service M anual    ee tow Replace The Heater       6         3   With the wrenches  disconnect the  heater by removing the two nuts on  the top of the element     7       4 ey    a    4  Unscrew the two nuts that hold the  heater to the e
34. t the power input cables        2   Unplug all connectors located  at the upper right corner of the  power box  4e Lift the cover        53 TSPA Power Spa Packs Service M anual    Mn Replace The Board    If the board of a TSPA pack has to be replaced   make sure to turn the power off           5   Disconnect the transformer 7  Disconnect the high limit sensor  connector  and the pressure switch cable        6  Disconnect all wires of the pump  8    Disconnect the heater output  light and ozone outputs with the by removing the two screws  pliers  at the bottom of the board        TSPA Power Spa Packs Service M anual 54    How To Replace The Board  ia             9  Remove the ground and    the triac screws   11    Beginning on the left side  gently  lift the board until it is released   j from the snap    a    a  E   k    10    The board is held in place  by six plastic standoffs       Note that most recent models of T SPA  made in 98  come with new releasable  standoffs  U se pliers to release standoff heads       55    TSPA Power Spa Packs Service M anual    in Replace The Board       13    Verify if the plastic mounting studs  are damaged  If so  replace the  damaged ones     14    Align the new board with the  standoffs and snap into place        15    Reinstall the triac screw  It is  important to hold the triac in place  with pliers while screwing to avoid  bending the pins     Do not over tighten     16    Put the ground screw in place     17    Connect all connector wi
35. tem  is working  properly     25 TSPA Power Spa Packs Service M anual    ee lift Error Message    The FrEE message is related to the freeze protection of the system   The system will enter a protective mode if it detects water cold enough to  freeze the pipes        Brea 7    1       Power can remain On     1   With a digital thermometer  verify  the temperature of the water        2   Ifthe water temperature is lower than  the desired temperature  measure the    voltage to the heater     Ifyou read around  240 vac  the  freeze protection system is working    properly     Ifyou do not read  240 vac  refer to  the  Spa not heating  section of this  manual        TSPA Power Spa Packs Service M anual 26     Nothing Works   Flow Chart                If nothing seems to work   follow this troubleshooting flow chart to identify the source of the problem         yes  lt  gt  no    Do you read    240 vac    k  w  Verify if i D aa 5 There is  the top side between a problem  control is line 1 amp  neutral with the  properly   20 vac electrical  connected to between wiring   the board  line 2  amp  neutral  ee on the board  Call an  All eight pins electrician   must be plugged in   amp  the black wire  must be on top  of the plug     Replace the transformer  fuse if there is still nothing on  the top side control display     If still nothing works   clean the pins of the  transformer orange connector   asmall coating of film may  cause a bad connection      Replace the transformer if   
36. ter temp  is 2  F higher  than set point  2  circulation pump on all the time     Temperature probe calibration  Code  r  Value  46 0 to 55 9    On each temperature probe  there is a calibration tag with a 3 digit  number  ex   495  To insure a good calibration of the unit  you must  enter the same 3 digit number into this parameter  disregard the  position of the dot         TSPA Power Spa Packs Service M anual    TSPA Power Spa Packs Service M anual    10    FLO Flow Chart    If an FLO message  problem with the pressure switch  pump is on but no  water pressure detected  appears on the top side control display  follow  this troubleshooting flow chart to identify the source of the problem        For packs manufactured before 1 198  you have to press a key after each step to reset the system     N ote that there must be enough water  in the spa for it to be used normally     Verify ifthe circulation pump parameter of  the low level prog  is set properly                        yes            lt  gt  no    Is the pump working     Refer to the  pump not    working  section   ys      lt Q     m  Is there anything limiting    the flow of water into the pipes  a  Remove anything that is Verify ifthe pressure switch  obstructing the filter  cable is properly connected  Clear any air locks to the pressure switch and   amp  verify the water valves  the board     yes    gt  no    Lower the set point at 60  F and  ys   lt  amp   v turn the pump off L ov  Short the the two terminals of  
37. wer  key   The icon will flash if the  blower isin low speed      4 Ifit still does not work  replace  the board        TSPA Power Spa Packs Service M anual 42    Blower Does Not Work  AM    If the blower on icon appears on the top side control display but the blower  still does not work  perform the following tests to correct the problem           le Ifthe icon appears on the  top side display   measure the voltage at the  blower outputs  P24  amp  P25  connectors on the board   in  high speed     You should read   120 vac for an 120 vac blower  240 vac for an 240 vac blower    2    e    3    4    5    6       beak eid  eB hed  RIES  ji i    Sr  I  I a                 Blower fuse    Replace the blower fuse if you  do not measure sufficient voltage     Replace the board if you still have  not any voltage   Refer to the   How to replace the board  section      If you do not get a good voltage  reading  check if you can restart the  blower afew minutes after it had been  shut off     Replace the blower if does not start  after cooling down     If the blower does restart after  cooling down  it is possible that the  blower does not draw sufficient air     In low level programming  change  the blower of speed to 2     7   Ifthe problem persists  create a bigger    Opening to let more air go to the  blower        43    TSPA Power Spa Packs Service M anual    TSPA Power Spa Packs Service M anual    44    Spa Light Flow Chart       If the spa light does not work   follow this troubl
38. y   or the O n O ff key for a TSPA 2  and hold it for 20 seconds  After this period   the display will show the parameter code  one or two digits  and a value  two or  three digits      Use the Up and Down arrows to change the parameter value and the Pump 2 key  to go from one parameter to the next  You must go through all parameters to get  out this mode  If you do not want to change a parameter  just press Pump 2 to go  to the following one        TSPA Power Spa Packs Service M anual 8       Low Level Programming    List of parameters        10     Pump 1  Code  P1  Value  1  single speed pump  2  two speed pump     Pump 2   Code  P2   Value  0  no pump  1  single speed pump  2  two speed  pump     3  3 speed blower output     Light   Code  LI   Value  0  no light  1  12 volts O n O ff    2  12 volts 3 intensities  3  120 volts  circulation pump output    4  Internal fiber box control  Fiber light on blower output  Fiber motor on CP output     Ozone   Code  03   Value  0  no ozone lamp  1  ozone activated during filter cycle   2  ozone output always on    AUX configuration   Display  AU x   Value  0  nothing installed  1  EXMS Fiber box controller installed  2  DJS 1 massage controller installed    Time format  Code  TI  Value  12  12 hours format  24  24 hours format     Current selection  Code  Cu  Value  1  no restrictions  O  Heater off when 2 pumps are running at high speed     Circulation pump   Code  CP   Value  0  no circulation pump  1  circulation pump off when wa
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
FU_lantern user manual  Command Line User's Guide  光の性質 (PDF:591KB)  Jøtul F 602 CB - Heat `N Sweep  Notice evolution- FINAL.indd - Height Safety Products and Projects  Melissa Cordless Jug Kettle 245-005 User's Manual  Helmholtz Nanoelectronic Facility  User's Guide    Copyright © All rights reserved. 