Home
SaniTEE Manual LETTER current - Bio
Contents
1. BIO MICROBICS INCORPORATED Better Water Better World Sani T Wastewater Screens Installation amp Service Manual FOR USE WITH SNT416 SNT418 SNT818 SNT 838 SNT1618 and SNT1638 SaniTEE Manual Bio Microbics Inc Revised December 2009 SaniTEE is a registered trademark of Bio Microbics Inc INSTALLATION amp SERVICE MANUAL FOR USE WITH SNT416 SNT418 SNT818 SNT838 SNT1618 SNT1638 GENERAL INFORMATION If you have questions regarding any Bio Microbics products please contact us 800 753 FAST 3278 or 913 422 0707 e mail onsite biomicrobics com DELIVERY INSPECTION SaniTEE screens are carefully manufactured and inspected at the factory prior to shipment Before and after uncrating the unit check the packaging for signs of shipping damage If there is evidence of damage or abuse notify Bio Microbics Inc at 800 753 3278 or 913 422 0707 About SaniTEE Wastewater Screens SaniTEE self cleaning wastewater deflection screens commonly known as septic tank effluent filters are designed to reduce suspended solids discharged in septic tank effluent by promoting natural sedimentation and excluding gas lifted particles from entering the outlet pipe Additionally SaniTEE s patented keyhole weir helps to attenuate surge flows delivering a more consistent flow for further treatment or dispersal These features help extend the life of a drain field reduce orifice clogging in effluent disposal s
2. 18 1 A 4 SaniTEE fits a standard 4 septic tank outlet tee or sweep Schd 35 40 amp 80 The center of the SaniTEE9 MUST be at least 38 inches 96 5 cm off the bottom of the tank a A short section of pipe may be attached to the bottom of the outlet tee to retain floatables 2 Place the SaniTEE into the outlet tee DO NOT USE GLUE The SaniTEE should fit snugly into the outlet tee 3 OPTIONAL EXTENDING SWAB HANDLES The exterior cleaning swab pipes may be easily extended using 4 schd 80 pipe and matching couplings Cut 24 pipes to the desired length glue and connect each extension pipe to the existing pipes using slip to slip couplings When completed glue the supplied swab handle to each pipe end 4 Reattach the SaniTEE handle with solvent welding to the 4 Schd 80 swab shaft or added extension pipe INSTALLATION PROCEDURE SNT818 838 1618 amp 1638 SNT818 amp SNT1618 amp SNT 1638 Notch amp Key E 1 Install the Top Diverter using concrete anchor bolts general rules for anchoring into concrete dictate bolt penetration lt 50 of wall Assure that it is placed correctly with respect to the manhole and other features of the tank See the drawings of each SaniTEE model for precise dimensions Properly seal any areas to prevent leaking 2 Place the SaniTEE9 into the Top Diverter The SaniTEE should fit snugly into Top Diverter with the Top Diverter key fittin
3. Inc is not responsible for consequential or incidental damages of any nature resulting from such things as but not limited to defect in design material or workmanship or delays in delivery replacements or repairs THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESSED WARRANTIES ANY WARRANTY IMPLIED BY LAW INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS IN EFFECT ONLY FOR THE WARRANTY PERIOD SPECIFIED ABOVE NO REPRESENTATIVE OR PERSON IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR TO ASSUME FOR BIO MICROBICS INC ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS Contact your local distributor for parts and service E Kee if ON WAHR Ree ac L r3 U rad rt Module System Serial Number System Designer Name Designer Phone Health Official Name Health Official Phone Manufacturer Name Bio Microbics Inc Manufacturer Phone 1 800 753 FAST 3278 Installed By Installer Phone a BIO MICROBICS Maintenance Provider Name INCORPORATED 8450 Cole Parkway Shawnee KS 66227 USA s Ph 913 422 0707 Fax 913 422 0808 Maintenance Provider Phone 800 753 FAST 3278 www biomicrobics com
4. g becomes more frequent than usual check the tank s sludge levels as it may need to be pumped Good septic system maintenance includes regular removal of sludge Check with local officials for recommendations or requirements LIMITED WARRANTY Bio Microbics Inc warrants that the SaniTEE product will be free from defects in material and workmanship for a period of one year from the date of purchase During the warranty period if any part is defective or fails to perform as specified when operating at design conditions and if the equipment has been installed and is being operated and maintained in accordance with the written instructions provided by Bio Microbics Inc Bio Microbics Inc will repair or replace at its discretion such defective parts free of charge Defective parts must be returned by owner to Bio Microbics Inc s factory shipping pre paid if so requested The cost of labor and all other expenses resulting from replacement of the defective parts and from installation of parts furnished under this warranty shall be borne by the owner This warranty applies only to the SaniTEE screen and does not include any of the plumbing drainage septic tank or disposal system Bio Microbics Inc reserves the right to revise change or modify the construction and or design of the SaniTEE screen or any component part or parts thereof without incurring any obligation to make such changes or modifications in present equipment Bio Microbics
5. g into the SaniTEE notch z SaniTEE notch si LT D 1 W Top Diverter key 3 OPTIONAL EXTENDING SWAB HANDLES The exterior cleaning swab pipes may be easily extended using 74 schd 80 pipe and matching couplings Cut 4 pipes to the desired length glue and connect each extension pipe to the existing pipes using slip to slip couplings When completed glue the supplied swab handle to each pipe end 4 Reattach the SaniTEE9 handles by solvent welding them to the 3 4 Schd 80 swab shafts FINAL INSTALLATION INSPECTION amp START UP It is the responsibility of the installer to ensure that the septic tank containing the SaniTEE will not float due to hydraulic conditions at the site Your local Bio Microbics distributor may provide installation inspection services If you have questions call Bio Microbics at 800 753 FAST 3278 or 913 422 0707 Always secure all access covers in place so that people cannot enter the tank without the use of proper tools DO NOT use flame or WARNING spark near a septic tank s access points Gases emanating from septic tanks can explode if ignited or deadly if inhaled BEFORE THE UNIT IS BACKFILLED Fill the tank to the normal operating level Check for leaks in all water tight seals Backfill the excavation 0 OD gt Lastly record all pertinent information at the end of this manual please note SaniTEE s do not have a serial number but maybe used in co
6. njunction with a FAST system that can be referenced with OPERATION amp MAINTENANCE Simple maintenance The SaniTEE should be swabbed annually or cleaned each time the septic tank is pumped If sewage flow is noticeably slowed by the SaniTEE more frequent cleanings may be necessary For installations other than single family homes more frequent cleaning may be necessary Inspect the SaniTEE as needed to make that determination Always secure all access covers in place so that people cannot enter the tank without the use of proper tools DO NOT use flame or A WARNING Spark near a septic tank s access points Gases emanating from septic tanks can explode if ignited or deadly if inhaled Only qualified service staff should open access ports and or covers Infectious organisms exist in a septic tank If any contact with A WARNING wastewater immediately wash and disinfect all exposed areas and contact personal physician Failure to do so could result in severe sickness or death CLEANING SaniTEE 1 Grasp the handle s of the cleaning swab and forcefully move up and down several times extending the entire length of the screen For the 8 amp 16 models MOVE THE SWAB HANDLES EVENLY Be sure to clean with both swabs Optional If a more thorough cleaning is desired remove the SaniTEE out of the outlet top diverter and rinse the device off If sludge builds up on the bottom of the SaniTEE screen or if required cleanin
7. ptional 24 19 mm schd 80 PVC pipe amp fittings to extend swab handles PVC saw PVC primer and glue weather appropriate Outlet sealing material or gasket may be included with septic tank FOR SaniTEE SNT416 and SNT418 ONLY Outlet tee or sweep schd 35 40 or 80 FOR SaniTEE SNT818 SNT838 SNT1618 and SNT1638 ONLY Anchor bolts for securing SaniTEE top diverter to the tank 8 Hammer drill and masonry bits Dd 99 QI SS YS SYSTEM COMPONENTS SaniTEE 416 amp 418 SUPPLIED EQUIPMENT a swab srat 1eoseveaa 4 SaniTEE 175 1 16FINSNTE 416 1 16 slots Body 175 1 8FINSNTE 418 s slots 5 fi Internal Swab 180 4SWAB x E 1 30 4 12 0 5 SaniTEE SNT1618 amp SNT1638 SUPPLIED EQUIPMENT COMMON NAME PART NUMBER TOAN Top Cap 180 CAPSTPPH16 J External Swab Shafts 2 180 SPVC3 4 Top Diverter 180 DT16 Internal Swab 180 SWBRINT16 n 180 SANSNMB 1618 1 3 slots o 16 Sani TEE Body fI 180 SANSNMB 1638 9s slots External Swab 180 SWBREXT16 95 2 6 _ External Swab Shafts 2 180 SPVC3 4 37 9 7 External Swab 180 SWBEXT8 SaniTEE 818 amp 838 SUPPLIED EQUIPMENT COMMON NAME PART NUMBER EH es ENS TS 2 Top Cap 180 CAPSTPPH8 3 Top Diverter 180 DT8 4 Internal Swab 180 SWBINT8 180 SANSNMB818 818 1 8 slots 8 SaniTEE Body 180 SANSNMB838 838 3 8 slots A DANS INSTALLATION PROCEDURE SNT416 amp SNT4
8. ystems and allow flexibility in the use of different types of effluent pumps GENERAL LAYOUT Tank Inlet Swab Handle Outlet Diverter not included with SNT416 amp 418 SaniTEE Screen Interior Cleaning Swab Exterior Swab included with SNT818 838 1618 amp 1638 Onl y a septic tank If any contact with wastewater immediately wash and disinfect all exposed areas and contact personal physician Failure WARNING to do so could result in severe sickness or death LOCATION Hazards exist in confined spaces such as a septic tank All confined space precautions must be followed if entering a tank Always A fth Tem keep tank openings covered during storage and installation SaniTEE screens are located on the outlet s or baffle walls of septic tanks and may be located in the same position relative to the house and water supply as any conventional septic system However some basic guidelines should be followed Avoid locating any septic tank in high groundwater areas where the tank could possibly float up and become dislodged m The SaniTEE device should be placed in the manhole as close as possible to the tank s outlet end This manhole should have a minimum diameter of 18 3 The SaniTEE device should be placed in the center of this manhole MATERIALS REQUIRED FOR INSTALLATION Note other tools may be needed to complete installation Septic tank that meets all applicable requirements and standards O