1. z 8 9 Fullstop Comma Query POINT LIGHTING CORPORATION Plant 61 West Dudley Town Rd Bloomfield CT Tel 01 860 243 0600 USA Mail P O Box 686 Simsbury CT 06070 email info pointlighting com Fax 01 860 243 0665 website www PointLighting com POINT oa LIGHTING CORPORATION MAINTENANCE AND SERVICE INSTRUCTIONS If the PHB LED beacon has stopped flashing turned off or the light output has noticeably decreased the beacon will need repairs The repairs may be performed in the field by a knowledge technician or may be returned to Point Lighting for repairs In the case of services in the field Point Lighting will provide a separate Service Manual 1S37001 M Service This Service Manual explains in detail how to troubleshoot any beacon problem and how to replace a failed internal component A PFB 37001 M Serive Manual can be obtained by contacting Point Lighting or emailing info pointlighting com Opening the beacon for service without contacting Point Lighting will voids the warranty If the beacon needs to be returned to Point Lighting for repairs return instructions can be obtained by contacting Point Lighting or emailing info pointlighting com PoINT LIGHTING CORPORATION Mail P O Box 686 Simsbury CT 06070 Plant 61 West Dudley Town Rd Bloomfield CT Tel 01 860 243 0600 USA Fax 01 860 243 0665 email info pointlighting com website www PointLighting com
2. 0 6875 17 5 i BOLT HOLES FORM A SQUARE WITH SIDES 9 375 238 POINT LIGHTING CORPORATION Mail P O Box 686 Simsbury CT 06070 Plant 61 West Dudley Town Rd Bloomfield CT Tel 01 860 243 0600 USA Fax 01 860 243 0665 email info pointlighting com website www PointLighting com POINT oa LIGHTING CORPORATION WIRING INSTRUCTION NOTE The PHB LED Beacon must be protected by a current limiting circuit breaker at the source of system power NOTE All electrical connections must be made inside a suitable junction box within 6 feet of the fixture The junction box is provided by others Unauthorized wiring modifications inside the PHB LED beacon will void the warranty NOTE All wiring connections and splices must be made using proper electrical practices per the National Electric Code NEC as well as any local electrical codes NOTE This product contains metal oxide varistor type surge protection Due to the leakage current inherent in this surge protection Point Lighting does not recommend using ground fault interrupter or similar type circuit breakers Circuit breakers such as GFI Ground Fault Interrupter ELCB Earth Leakage Circuit Breaker or similar type circuit breakers may experience nuisance tripping The PHB LED Beacon is shipped with six 6 feet of SOOW cable The cable has three 3 conductors colored black white and green Cable Information gt Jacket Black PVC gt Conductors Three 3 conductor 14 AW
3. 00 USA Fax 01 860 243 0665 email info pointlighting com website www PointLighting com POINT it 2013 02 August 2012 LIGHTING e CORPORATION FIGURE 3 AC FIXTURE WIRING DIAGRAM 120 OR 220 VoLT AC a LINE POWER BLACK Z NEUTRAL WHITE GROUND GREEN FIGURE 4 DC FIXTURE WIRING DIAGRAM 12 24 or 48 VoLT DC T T a lt POSITIVE BLACK lt NEGATIVE WHITE GROUND GREEN f POINT LIGHTING CORPORATION Mail P O Box 686 Simsbury CT 06070 Plant 61 West Dudley Town Rd Bloomfield CT Tel 01 860 243 0600 USA Fax 01 860 243 0665 email info pointlighting com website www PointLighting com PAIN ARNG CORPORATION IS37001 M 02 August 2012 Page 6 of 7 POWER UP PROCEDURE Once the PHB LED Beacon has been installed properly the system power may be activated The PHB LED Beacon will take about 2 seconds to initialize light output and start the Morse code sequence The PHB LED beacon will repeat the Morse code sequence until power is removed The sequence follows International Morse Code Standards on characters and timing Compare the sequence observed from the PHB LED beacon to Figure 5 International Morse Code Characters to ensure the PHB LED beacon is flashing the correct message FIGURE 5 INTERNATIONAL MORSE CODE CHARACTERS Ae N B o x P D Q E R F s G T H u I v J zs w K s x b a Y M
4. AN AND DRY CONDITIONS DO NOT ATTEMPT ANY TESTING OR REPAIR PROCEDURE NOT STATED IN THE MANUAL CONTACT POINT LIGHTING FOR RETURN REPAIR SERVICE INSTRUCTIONS FURTHER SERVICE INSTRUCTIONS CAN BE FOUND IN THE SERVICE MANUAL IS37001 M SERVICE WARNING DO NOT INSTALL AIR TERMINALS LIGHTNING RODS NEAR OR ON ANY POINT LIGHTING FIXTURES AIR TERMINALS WILL INCREASE THE POSSIBILITY OF FAILURES AND WILL VOID THE FACTORY WARRANTY FIXTURE GROUND WIRES MUST NOT BE CONNECTED TO BUILDING TOWER LIGHTNING PROTECTION SYSTEM DOWN CONNECTORS IMPORTANT NOTICE The installer assumes full responsibility for the proper application and safe installation of this unit in accordance with these instructions the National Electric Code and all other state and local codes and practices POINT LIGHTING CORPORATION accepts no responsibility for damages to property or injury to personnel for the improper use of this product or its failure under any circumstances POINT LIGHTING CORPORATION s warranty is limited to the replacement of the defective unit only if the failure is the result of a manufacturing defect PAIN ARNG CORPORATION IS37001 M 02 August 2012 Page 2 of 7 PRODUCT OVERVIEW Input Voltage Range 93 144 V 50 60 Hz 120 Volt AC Nominal 176 264 V 50 60 Hz 220 Volt AC Nominal 10 8 13 2 V 12 Volt DC Nominal 21 6 26 4 V 24 Volt DC Nominal 43 2 52 8 V 48 Volt DC Nominal Wattage 102 2 watts Peak AC Only 109 2 w
5. G gt Outer Diameter 5 inches 12 8 mm 55 inches 13 9 mm gt Maximum Voltage 600V gt UL Rated The fixture wiring instruction is different for AC and DC fixtures read the appropriate wiring section below AC Fixture Wiring 120 or 220 Volt AC Fixtures The fixture neutral zero wire is white splice the fixture neutral wire to the system neutral zero The fixture line power wire is black splice it to the system line hot The green wire is the fixture s ground splice it to the system ground See Figure 3 AC Fixture Wiring Diagram Make splices using proper electrical practices in suitable splice box per NEC and local codes Once the wiring has been connected properly see Power Up Procedure for details on Power Up procedure and system operations DC Fixture Wiring 12 24 or 48 Volt DC Fixtures The negative wire is white splice the negative wire to the system negative The positive wire is black splice it to the system positive The green wire is the fixture s ground splice it to the system ground See Figure 4 DC Fixture Wiring Diagram Make splices using proper electrical practices in suitable splice box per NEC and local codes Once the wiring has been connected properly see Power Up Procedure for details on Power Up procedure and system operations POINT LIGHTING CORPORATION Mail P O Box 686 Simsbury CT 06070 Plant 61 West Dudley Town Rd Bloomfield CT Tel 01 860 243 06
6. POINT cant 201 age 10 LIGHTING INSTRUCTION MANUAL to i PHB 37001 M POINT MORSE CODE BEACON MORSE CODE MESSAGE The Point LED Heliport Beacon US Patent 2011 0121734 A1 is a medium intensity identification beacon used to mark a heliport or airport location The Morse code option shall flash the message H unless the user specifies a different message The flash message is factory programmed and preformed by internal components of the beacon All exterior aluminum cast beacon parts shall be powdercoat painted aviation yellow for corrosion resistance that meets the US Military Standard Salt Fog Test conducted per MIL STD 810E method 509 3 Procedure I CATALOG NUMBERING SYSTEM Point Type Color Fixture Voltage Options PHB 37001 R Red 1 120 Volt AC MT Marine Treatment G Green 2 220 Volt AC M Flashing Morse Code Message C Clear White 3 12 Volt DC NC NVG Compatible Y Yellow 4 24 Volt DC 5 48 Volt DC CONFORMS TO WTER TE UL STD 1598 A UL STD 1598A us CERTIFIED TO CSA STD C22 2 No 250 0 WARNING TURN OFF THE ELECTRICITY AT THE SOURCE BEFORE INSTALLING WARNING OPENING THE BEACON BEFORE INSTALLATION VOIDS THE WARRANTY NO INTERNAL WIRING IS NECESSARY IN THE FIELD WARNING DO NOT OPEN THE BEACON UNLESS THERE HAS BEEN AN IN SERVICE FAILURE IF THE BEACON IS OPENED FOR ANY REASON THE UPPER AND LOWER LENS GASKETS MUST BE REPLACED WARNING ALL SERVICE MUST BE PERFORMED INSIDE A MAINTENANCE FACILITY UNDER CLE
7. atts Peak DC Only Average Wattage depends on Morse Code Message Volt Amps 162 4 VA 120 Volt Only Intensity 2 000 Candelas color 2 500 Candelas white Current 1 35 Amps Peak measured 120 V 50 60 Hz 0 69 Amps Peak measured 220 V 50 60 Hz 9 10 Amps Peak measured 12 Volt 4 54 Amps Peak measured 24 Volt Average Current depends on Morse Code Message Temperature Ratin 55 C 67F 131 Dimensions L x W x H 15 381 x 15 381 x 12 304 Inches mm Weight 41 Lbs 18 6 kg FIGURE 1 PFB 37001 OUTLINE DRAWING POINT LIGHTING CORPORATION Mail P O Box 686 Simsbury CT 06070 Plant 61 West Dudley Town Rd Bloomfield CT Tel 01 860 243 0600 USA Fax 01 860 243 0665 email info pointlighting com website www PointLighting com POINT og LIGHTING CORPORATION MOUNTING INSTRUCTION The base of the PHB LED Beacon is made of industrial grade cast aluminum for use in the most rugged environments The base has a four 4 hole bolt pattern on a 13 25 inch diameter bolt circle See Figure 2 Mounting Bolt Pattern The holes have a diameter of 6875 inches 17 5 mm Point Lighting recommends using 5 8 inch hardware supplied by other Mount the PHB LED Beacon securely on a flat horizontal surface the PHB LED Beacon must be level FIGURE 2 MOUNTING BOLT PATTERN DIMENSIONS INCHES 13 25 337 MILLIMETERS eat DIAMETER BOLT CIRCLE es i
Download Pdf Manuals
Related Search
Related Contents
2 Bedbug - KellySolutions.com HP Pavilion 17-f035nr Generator Operation Manual Flex 10 UG SP Les Licences Libres : creative commons Samsung SM-P550 Εγχειρίδιο χρήσης Toshiba Pocket PC e400 Wiley Professional ASP.NET 2.0 Security, Membership, and Role Management Severin EK 3056 Worldwide Lighting W83041C22 Instructions / Assembly Copyright © All rights reserved.