        G2 Optima Plus® Flushometer
         Contents
1.    1    Screwdriver Bak Chek   Stop CP     complete  3 4    Screwdriver Bak Chek   Stop CP     complete  Control Stop Repair Kit t   Control Stop Repair Kit     CP Bonnet  t   CP Bonnet     Vandal Resistant Control Stop Cap Assembly    Vandal Resistant Control Stop Cap Assembly    3 4    Decorative Stop Cap   1    Decorative Stop Cap    Item  No  Code No  Part No    1  0325160 EBV 138 A  0325161 EBV 139 A  0325166 EBV 149 A  0325167 EBV 150 A   2  0325168 EBV 142 A   3  0325172 EBV 130 A  0325170 EBV 132 A   4  0325169 EBV 131   5  0325804 EBV 14  0325210 EBV 168  3325524 EBV 31 A   6  3325450 EBV 129 A C  3325451 EBV 129 A U   7  0325171 EBV 134   8  3325456 EBV 145 A  3325089 EBV 1010 A   9  3325453 EBV 136 A   10  SEE CHART NEXT PAGE     Refer to Page 3 2 3 for instructions regarding solenoid replacement    ACCESSORIES   11  0325107 EBV 91   12  0305823 EBV 22   13  0325170 EBV 132 A   VALVE COMPONENT PARTS   14  3323182 V 651 A   15  0393004 V 600 AA  0393006   600 AA  3393007   600 AA   16  0306125 F 5 AW  0306140 F 5 AU  0306146 F 5 AT   17  0308676 H 550   18  0308801 H 551 A   19A  5308696 H 553   19B  5308381 H 552   20  3308386 H 700 A  3308384 H 700 A   21  3308853 H 541 A  3308856 H 543 A   22  0308612 H 622  0308843 H 577   23  3308772 H 1010 A  3308790 H 1009 A   24  3325816 EBV 1019 A  3308866 H 574   25  3325814 EBV 1017 A    Handle Cap     Metal    t For use with 1    and 3 4    H 700 A and 1    H 600 A Bak Chek   screwdriver control stop    For use with H 60
2.   FLEX TUBE  DIAPHRAGM    Repair Parts and Maintenance Guide    G2 Optima Plus   Flushometer    OVERRIDE BUTTON         COVER    LOCKING RING STOP COUPLING    f    CONTROL STOP        SUPPLY FLANGE  FLUSH CONNECTION     VACUUM BREAKER  TI  SPUD COUPLING    REGULATORS    The flush volume of the flex tube diaphragm kit is controlled by the  regulator  Regulators are identified by color  Some flex tube diaphragm kits  are supplied with multiple regulators  The installer must make sure the  proper regulator is used when installing the flex tube diaphragm kit     REGULATOR  SOLD 6 PER PACKAGE     OUTLET COUPLING    SPUD FLANGE       Regulator   Code No  Part No  Description Color   5325122 EBV 95 Urinal 0 5 gpf 1 9 Lpf GREEN  5325122 EBV 95 Urinal 1 0 gpf 3 8 Lpf GREEN  5325129  EBV 102 2 Urinal 1 5 gpf 5 7 Lpf BLACK  5325130  EBV 102 1 Urinal 3 5 gpf 13 2 Lpf WHITE  5325122 EBV 95 Closet 1 28 gpf 4 8 Lpf GREEN  5325122 EBV 95 Closet 1 6 gpf 6 0 Lpf GREEN  5325130  EBV 102 1 Closet 3 5 gpf 13 2 Lpf WHITE  5325128 EBV 101 Closet 2 4 gpf 9 0 Lpf BLUE    EBV 1020 A and EBV 1022 A are supplied with multiple flush volume regulators   The installer must use the correct regulator when installing the kit     REGULATOR   MUST BE  INSTALLED    O RING PAST O RING     Gs  EIS       FLEX TUBE  DIAPHRAGM    082009    SLOAN     SOLENOID REPLACEMENT    Code No  PartNo  Description  3325453 EBV 136 A Solenoid operator    blue module         1  Turn off water and relieve pressure by loosening Tailp
3.  Enlarged by pass in diaphragm  Replace flex tube diaphragm   D  Control stop not adjusted properly  Readjust control stop     E  Inadequate volume or pressure at supply  Increase water pressure  or supply  flow  to valve  Consult factory for assistance     8  Too much water to fixture     A  Wrong flush volume regulator installed in flex tube diaphragm kit   Install the correct regulator     B  Control stop not adjusted properly  Readjust control stop     C  Wrong Optima Plus model installed  i e   3 gpf model installed on 1 0  or 1 5 gpf urinal fixture     D  Dirt in diaphragm by pass  Clean under running water or replace flex  tube diaphragm     Note  The EBV 46 A beam deflector is no longer required or available  for the G2 Optima Plus     CARE AND CLEANING INSTRUCTIONS    DO NOT use abrasive or chemical cleaners to clean the G2 Optima Plus  they  may dull the luster and attack the plastic cover and the chrome finish of the  Flushometer  Use ONLY mild soap and water  then wipe dry with clean cloth  or towel  While cleaning the bathroom tile  the Optima Plus should be  protected from any splattering of cleaner  Acids and cleaning fluids can  discolor or remove chrome plating        
4. 0 A 3 4    screwdriver Bak Chek   control stops          SLOAN     The Sloan Valve Company introduced its Optima Plus   battery operated  sensor Flushometer in 1992  revolutionizing the flushing of water closets  and urinals  In both new construction and retrofit applications  the use of the  Optima Plus has become the standard method for many facilities to improve  restroom hygiene and ensure handicap accessibility compliance     In May  2003 Sloan introduced the G2 Optima Plus     The G2 Optima Plus builds on the success of the original product and offers  many technological advancements to further improve on performance and  reliability expected of sensor operated plumbing  In addition to a new  aesthetic design  the G2 Optima Plus features a new state of the art  electronic and optical package and a unique solenoid operator that keeps the  moving components of the solenoid completely isolated from the water  supply  This ensures long life and low maintenance regardless of local   water condition     The G2 Optima Plus replaces the original Optima Plus product  which was  phased out of production in mid 2003     The Sloan G2 Optima Plus automatic battery powered Flushometer relies on  an infrared sensor to detect a user and activate a flushing cycle  No physical  contact with the Flushometer surface is necessary  assuring sanitary  protection  G2 Optima Plus Flushometers are ADA compliant devices     The Flushometer is triggered by means of an active infrared sensor  The  
5. JUSTMENT PROCEDURE    For the first ten  10  minutes of operation  a visible red light flashes in the    sensing window of the G2 Optima Plus Flushometer when a user is  detected  This visible red light feature can be reactivated after ten  10   minutes by opening and closing the battery compartment door or holding  the override button for  1  minute     Check the range by stepping toward the unit until the red light flashes   indicating the sensor   s detection of a user  Adjust the range potentiometer  screw located on top of the sensor module a few degrees CLOCKWISE to  increase the range or a few degrees COUNTERCLOCKWISE to decrease the  range  Repeat this adjustment until the desired range is achieved     Always determine the sensing range with metal cover and lens  window on top of the unit     Important  Adjust in small increments only  Range potentiometer  adjustment screw rotates only 3 4 of a turn  DO NOT over rotate     When range adjustment is satisfactory  replace the rubber plug  Reinstall  override button and tighten the two screws on top of the unit     Repair Parts and Maintenance Guide    G2 Optima Plus   Flushometer       7 64    ALLEN WRENCH    COVER ASSEMBLY    ELECTRICAL CONNECTOR  RECEPTACLE       BATTERY COMPARTMENT COVER        COUNTERCLOCKWISE    G    Decreases  Range    CLOCKWISE    9    Increases             062006    SLOAN     Repair Parts and Maintenance Guide    G2 Optima Plus   Flushometer    TROUBLESHOOTING AND MAINTAINING THE SLOAN G2 OPTIMA 
6. Optima Plus sensor emits a continuous invisible light beam  When a user  enters the beam   s effective range  the beam is reflected into the Optima  Plus scanner window  The user is now detected  After the user moves out of  the effective range of the sensor  a signal is sent to the Flushometer  solenoid and  after appropriate arming and or flush delays  the flush cycle   is initiated     FLEX TUBE DIAPHRAGM KIT   Regulator  Code No  Part No  Description Color    3325003 EBV 1023 A Urinal 0 5 gpf 1 9 Lpf  GREEN  3325000 EBV 1022 A Urinal 1 0 gpf 3 8 Lpf GREEN  3325000 EBV 1022 A Urinal 1 5 gpf 5 7 Lpf t BLACK  3325001 EBV 1020 A Urinal 3 5 gpf 13 2 Lpf t WHITE  3325031  EBV 1024 A Closet 1 28 gpf 4 8 Lpf GREEN  3325001 EBV 1020 A Closet 1 6 gpf 6 0 Lpf   GREEN  3325014  EBV 1021 A Closet 2 4 gpf 9 0 Lpf BLUE  3325001 EBV 1020 A Closet 3 5 gpf 13 2 Lpf WHITE  3325001 EBV 1020 A Closet 4 5 gpf 17 0 Lpf    WHITE    t EBV 1020 A and EBV 1022 A are supplied with multiple regulators      A0 5 gpf  1 9 Lpf  urinal kit can be converted to a 1 0 gpf  3 8 Lpf  by cutting and removing the  smooth A 164 flow ring from the guide       For a 4 5 gpf  17 Lpf  water closet flush use EBV 1020 A with the white regulator  and cut and remove the  A 164 flow ring from the guide      Color of regulator to be used with flex tube diaphragm to obtain the listed flush volume     O RING  Code No  Part No  Description  5325056 EBV 83 O ring     6 per package       O RING  a  Code No  5325056     Ee     
7. PLUS   FLUSHOMETER    IMPORTANT  This product contains mechanical and or electrical  components that are subject to normal wear  These components should be  checked on a regular basis and replaced as needed to maintain the valve   s  performance     Never open Control Stop to where the flow from the valve exceeds the flow  capability of the fixture  In the event of a valve failure  the fixture must be  able to accommodate a continuous flow from the valve     ATTENTION INSTALLERS  With the exception of the control stop inlet   DO NOT USE pipe sealant or plumbing grease on any valve component or  coupling  To protect the chrome or special finish of Sloan Flushometers   DO NOT USE toothed tools to install or service these valves  Use our A 50  Super Wrench    or other smooth jawed wrench to secure couplings   Regulations for low consumption fixtures  1 6 gpt 6 0 Lpf closets and   1 0 gpt 3 8 Lpf urinals  prohibit use of higher flush volumes     1  Sensor flashes continuously only when user steps within range     A  Unit in start up mode  no problem  This feature is active for the first  ten  10  minutes of operation     2  Valve does not flush  sensor not picking up user   A  Range too short  increase the range     3  Valve does not flush  sensor picking up opposite wall or surface   or only flushes when someone walks by  Red light flashes  continuously for first 10 minutes even with no one in front of  the sensor     A  Range too long  shorten range   4  Valve does not flush ev
8. SLOAN     20       Earlier model with  EBV 36 A body     lt  gt   Fl  SS    012010    Repair Parts and Maintenance Guide    G2 Optima Plus   Flushometer    For use with Sloan   s G2 Optima Plus   Flushometer introduced May  2003     For older Optima Plus   Flushometers  produced from 1992     2003  and  Regal Pro   Optima Plus   Flushometers see pages 3 2 6 thru 3 2 11     SENSOR MODULE COMPONENT PARTS    Description  G2 Cover Ring Sensor Assembly     Water Closet  G2 Cover Ring Sensor Assembly     Urinal    G2 Cover Ring Sensor Assembly     Water Closet  w Zurn Ring    G2 Cover Ring Sensor Assembly      Urinal w Zurn Ring    Cover Assembly    Override Button Assembly includes screws  amp  hex  wrench    screws  2  and Allen Wrench Only  Lens Window Cover   Locking Ring CP   Locking Ring CP   Locking Ring     for Zurn Valves   G2 Electronic Module     Water Closet  G2 Electronic Module     Urinal   Cover Rest Plate    G2 Inside Cover Assembly  includes solenoid    metal cover only     Inside Cover Assembly  excludes solenoid   solenoid  For G2 Modules only    Flex Tube Diaphragm Kit    Trimpot Adjustment Screwdriver  strap Wrench  Allen Wrench    Vacuum Breaker Repair Kit   3 4    x 9    CP Vacuum Breaker   1 1 4    x 9    CP Vacuum Breaker   1 1 2    x 9    CP Vacuum Breaker   3 4    CP Spud Coupling   1 1 4    CP Spud Coupling   1 1 2    CP Spud Coupling   CP Stop Coupling   CP Adjustable Tailpiece 2 1 16    long   O ring     24 per package   Locking ring     12 per package
9. en after adjustment     A  Range adjustment potentiometer set at full    max    or full    min    setting   Readjust potentiometer away from full    max    or    min    setting     B  Batteries completely used up  replace batteries     C  Problem with electronic sensor module  replace electronic sensor  module     5  Unit flashes 4 quick times when user steps within range   A  Batteries low  replace batteries   6  Valve does not shut off     A  By pass orifice in diaphragm is clogged with dirt or debris  or by pass  is clogged by an invisible gelatinous film due to    over treated    water   Remove flex tube diaphragm and wash under running water     Note  Size of orifice in the by pass is of utmost importance for the  proper metering of water by the valve  DO NOT ENLARGE OR  DAMAGE THIS ORIFICE  Replace flex tube diaphragm if cleaning  does not correct the problem       Dirt or debris fouling stem or flex tube diaphragm  Remove flex tube  diaphragm and wash under running water     O ring on stem of flex tube diaphragm is damaged or worn  Replace  O ring if necessary       Problem with solenoid  If cleaning does not correct problem  replace  with new solenoid operator     JJ    O    J    062007    7  Not enough water to fixture     A  Wrong flush volume regulator installed in flex tube diaphragm kit   Install the correct regulator     B  Wrong Optima Plus   model installed  i e   1 0 gpf urinal installed  on 3 5 gpf closet fixture  Replace with proper Optima Plus model     C 
10. iece  coupling and re tighten  Loosen and remove top screws along  with the outer cover assembly        2  Disconnect wire clip from battery door and remove module from  inner metal cover assembly        3  Remove Solenoid by turning counter clockwise  Remove any  remaining O rings or parts in orifice      i a    Back View       4  Remove black plastic Housing from the threaded end of new  Isolated Operator by unscrewing  counterclockwise   It is normal  to find fluid inside this housing        Front View    102008    For G2 Optima Plus   modules  identified by a    Repair Parts and Maintenance Guide    G2 Optima Plus   Flushometer    5  Make sure all O rings  2  are installed on the grey End cap  of the new Isolated Operator  Install Isolated Operator by  threading it  clockwise  into the Housing  Tighten with fingers  beyond just snug                gt           6  Mount module on inner cover assembly  Reconnect the plastic  clip on the battery door        7  Assemble outer cover assembly     T  UN       8  Turn on water at control stop  Installation complete         Close up       Note  Verify that rubber insert is installed             SLOAN     BATTERY REPLACEMENT    When G2 Optima Plus   has approximately 4 000 flushes left  the same red  light that appears at start up will flash four  4  times quickly whenever an  object is detected  When this occurs  we recommend changing the batteries  as follows     When required  replace batteries with four  4  alkaline type AA bat
11. teries   Note  Water does not have to be turned off to replace batteries     Loosen the two  2  screws on top of unit  Remove the complete cover  assembly  Lift the sensor module from its plate  Unplug the electrical  connector from battery compartment cover  Loosen the retaining screw on  battery compartment cover and remove battery compartment cover  Install  four  4  alkaline type AA batteries exactly as illustrated at right     Install battery compartment cover and secure with retaining screw  Make  certain that battery compartment cover is fully compressed against gasket  to provide a seal  Do not overtighten  Plug the electrical connector into the  battery compartment cover  Reinstall the sensor module onto the plate   Reinstall the complete cover assembly onto the plate  Tighten the two    2  screws on top of the unit     RANGE ADJUSTMENT  ADJUST ONLY IF NECESSARY     The G2 Optima Plus has a factory set sensing range    Water closet models     22  to 42   559 mm to 1067 mm    Urinal models     15  to 30   881 mm to 762 mm    The Factory setting should be satisfactory for most installations     If the range is too short  i e   not picking up users  or too long  i e   picking  up opposite wall or stall door  the range can be adjusted     Note  Water does not have to be turned off to adjust range     Loosen the two screws on top of the unit  Remove the override button   Remove the rubber plug from top of electronic sensor module to uncover  the potentiometer     RANGE AD
    