Home
SERVICE MANUAL - Appliance Factory Parts
Contents
1. After 15 seconds the display will revert back to room temperature Temperature is only adjustable in cool mode The time is adjustable between 1 12 hours Note By pressing both A W set buttons at the same time the display will toggle between Celsius and Fahrenheit After switching the air conditioner off you must wait 3 minutes before switching it back on again 4 OPERATION Air Conditioner Remote Control batteries not included The functions work the same as your air conditioner s touch controls All key function can be accessed from the remote control CONTROL PANEL Power Control LCD Display Time Temperature Set Control e Used for adjusting the timer and temperature e The default display on control panel is room temperature e When or key is pressed in On Off Fan Speed Control HIGH MED S LOW cool mode the set temperature is a displayed and may be adjusted After 15 seconds the display will revert back On Off Timer Control pa Off Timer Control cz to room temperature e Timer setting is available from 1 12 hours In running mode Cox by presina the Kaya Po ne Auto switch off y pressing y s In stand by mode a Auto switch on Press a or button to adjust the time setting for 1 hour interval WHY Fahrenheit Celsius button Notes Do not drop the remote control Do not place the remote control in a location exposed to direct s
2. OPERATING CYCLE 4 0 250 MODEL LS 40T1 4P OUTDOOR OUTPUT MOTOR POWER 33 OPERATING CYCLE 6 0 250 MODEL TURBINE WT 15T1 01 FAN MOTOR OUTPUT POWER 2 CAPILLARY 2 6 0 D 1 6 1 D 950 L EVAPORATOR 3R14S17FPI CONDENSER 3R14S21FPI REFRIGERANT 460 WEIGHT REFRIGERATOR SYSTEM DIAGRAM INDOOR RADIATOR DRUM INDOOR MOTOR EVAPORATOR INDOOR RADIATOR FAN OUTDOOR RADIATOR DRUM OUTDOOR RADIATOR FAN OUTDOOR MOTOR LIQUID ACCUMULATOR COMPRESSOR CAPILLARY CONDENSER AIR FILTER WATER BLADE WATER MOTOR SCHEMATIC WIRING DIAGRAM ate q BLUE
3. HAIER AMERICA SERVICE MANUAL AIR CONDITIONER HPRIOXCO Part Number AC 8888 148 S LU me ll la Ly Important points on service and flow chart for inspecting and repairing the unit Appearance out ward Troubleshooting Operation Remote control Technical specifications Refrigerator system diagram and schematic wiring diagram Exploded view Parts list M This manual is forthe use of technical personnel entrusted with maintenance Widetech reserves the right to change this dehumidifier s 115V 60Hz casing circuit and parts without notice Date 2006 06 15 Version 1 0 IMPORTANT POINTS ON SERVICE OPERATING SAFETY Please follow these instructions carefully e Unplug the unit to avoid any danger from electric shock before disassembling the unit for repair e If there is any sound of the refrigerant circulating when in operation avoid touching the cooling coils e f you need to perform any welding or soldering be sure you are in a well ventilated area e Only a qualified professional should perform any welding on the unit e When repairing the unit the specifications listed in this manual must be strictly adhered to when replacing any components e When replacing any electrical components they should be factory approved units Be sure that any electrical components are properly wired and in place FLOW CHART FOR INSPECTING AND REPAIRING THE UNIT AI
4. If batteries in the remote controller exhausted If the plug is not properly plugged If the set temperature is close to room temperature you can low the set temperature Air outlet be blocked by obstacle Take the obstacle away Run a short while only f the door or window open If there is other heater appliance work like heater or lamp etc Run but not cool The air filter is dirty please clean it Air outlet or intake be blocked Set temperature is too high Drain the water into a prepared container by the drainage pipe on the rear panel of the unit If still doesn t work please consult a qualified Do not run and water technician full indicator lights OPERATION CONTROL PANEL Fan Speed Control Warning Light E Display Ooo Ow Qeon Or O medium Hr ao Ormor Oran Orion E e o O O Power Timer Mode Fan Speed mom A gt Power Control T Timer Control Timer Temp Mode Control Set Controls Power Control The power control turns the unit on and off Warning Light A Condensed water may accumulate in the unit If the internal tank becomes full the Warning Light will shine and the unit will not operate until the unit has been drained Mode Control The Mode Control has 3 settings e Cool e Dehumidify e Fan The settings are adjusted with Mode Control button A light will indicate which setting is currently being used e Cooling Mode Durin
5. R CONDITIONER CHECK THE POWER WON T START MORONER ii SWITCH PLUGANDSOCKET RE PLUGING THE ARE LOOSE POWER SUPPLY CORD TESTING BY TIMER FAILURE ELECTROSCOPE CHANGE THE PROTECTOR FAILURE PROTECTOR CHANGE THE CAPACITOR FAILURE CUPRCIROR WIRING ISLOOSE RE CONNECTING REFRIGERANT BARAGE CHANGE THE AIR CONDITIONERWITH15KG CM TROUBLE SHOOTING NITROGEN GAS FROM LOW PRESSURE SIDEAND THE SYSTEM DETECT THE LEAKING POINT BYSOAP USE OXYACETYLENE AND PLUS 5 RUNNING THE VACUUM CHANGE COOLANT AND SILVER SOLDER TO WELD THE EVACUATION FOR MORE PROCEED RUNNING TEST CRACKED POINTS THAN 15 MINUTES RUNNING TEST CHANGE THESWITCH AIR CONDITIONER COMPRESSOR WON T WON T COOL START PROPERLY APPEARANCE OUT WARD Control panel FRONT SIDE Handle hole Front panel Air filter Rear panel LLLI EY Air outlet Heat exchange goo c LJ Ww Power supply cord Water outlet drain TROUBLESHOOTING If the protector trip or fuse is blown Please wait for 3 minutes and start again protector device may be preventing unit Does not run fo Won
6. g the cooling mode the air is cooled and hot air is exhausted to the outside through the exhaust tube Adjust fan speed and air temperature to suit your desired comfort level Note The air exchange hoses must vent outside the room when using cool mode e Dehumidify Mode Air is dehumidified as it passes through the unit without being in full cooling mode If room temperature is 25 degree Celsius fan speed can be adjusted otherwise fan speed is fixed to Low Note The warm air exchange hoses must vent inside the room when using Dehumidify Mode not outside as it does when cooling lf the unit is vented outside some cooling will occur e Fan Mode Air is circulated throughout the room with no cooling Note unit does not need to be vented in Fan mode Fan Speed Control The Fan Speed Control has 3 settings High Medium and Low Timer Auto turn off With machine in running mode press timer button to select number of hours you would like the unit to run in air conditioning mode until it automatically shuts off Auto turn on With machine in stand by mode press timer button to select number of hours until you would like the unit to automatically start running in air conditioning mode Timer Temp set controls e Used for adjusting the timer and thermostat e The default display is room temperature e In cooling mode when A or y button is pressed the set temperature is displayed and may be adjusted
7. unlight Mode Control Press this button to change the operation mode in the order of Cool gt Dehumidify ene The remote control should be placed about 1 meter or more away from TV or any electical appliances Battery replacement Remove the cover on the back of the remote control and insert the batteries with the and poles pointing in the proper direction a ag Ont O Enr Oq n B 4 E CO 15v0 CO 15v8 Oo n CAUTION A Use only AAA or IEC RO3 1 5V batteries Remove the batteries if the remote control is not used for a month or longer Do not attempt to recharge the supplied batteries All batteries should be replaced at the same time do not mix old battery Do not dispose of the batteries in a fire as they may explode TECHNICAL SPECIFICATIONS AIR CONDITIONER ITEM UNIT HPR10XC6 OUTER DIMENSION 470W 900H 370D REFERENTIAL USING AREA 16 22 RATED VOLTAGE COOLING CAPACITY 115 60 DEHUMIDIFYING CAPACITY 1 6 RUNNING CURRENT 9 0 POWER CONSUMPTION 950 INDOOR AIR VOLUME 380 MODEL 2R12S3R126A INPUT POWER 740 OPERATING COMPRESSOR CYCLE 35 250 PROTECTOR MRA98503 or MRA98706 or MRA98706 9090 LOCKED ROTORAMPS 6 9 MODEL LS 13T3 4P INDOOR OUTPUT MOTOR POWER 17