1. Adtemp Ii 413 Digital Fever Thermometer USE CARE amp MAINTENANCE Intended Use A digital thermometer is a device used to measure the body temperature of a patient by means of a transducer coupled with an electric signal amplification conditioning and display unit Safety Information e High prolonged fever requires medical attention especially for young children Please contact your physician e Do not allow children to take their temperatures unattended e Read the enclosed instructions carefully to ensure accurate temperature readings Temperature readings are affected by many factors including exercise drinking hot or cold beverages prior to taking a reading as well as technique e Do not allow children to walk or run during temperature taking The rigid probe could present a hazard Oral underarm and rectal temperatures vary by approximately 1 F 0 5 C e WARNING Keep battery out of children s reach Swallowing battery could be harmful Battery should not be recharged or placed into extreme heat as it may explode e CAUTION Do not take an axillary temperature through patient s clothing Direct probe cover to skin contact is required e CAUTION Biting the probe tip while taking a temperature may result in damage to the probe e CAUTION Do not autoclave Please note the cleaning procedures described in this manual How to take temperature ae 1 Place a probe cover carefully over the tip Figure 1 S
2. Specific legal rights stipulated in your state may guide this warranty If you have a legitimate claim under this warranty send item s postage paid to Service Center Attn Repair Dept 55 Commerce Dr Hauppauge NY 11788 Please include your name and address phone no proof of purchase and a brief note explaining the problem your return address and 2 00 to cover shipping and handling AMERICAN DIAGNOSTIC CORPORATION ADC Inspected in the U S A eat valt tel 631 273 9600 1 300 232 2676 Hauppauge NY 11788 El 09 l efa JOUU 1 oUU 2oc ic fax 631 273 9659 www adctoday com ADC UK Ltd email info adctoday com Unit 6 P014 1TH United Kingdom IB p n 93 413 00 rev 3 english Printed in China
3. elect oral underarm or rectal as your measurement Figure Site based on the individual requiring a temperature measurement NO Push the Multi Function button located beside the display window The thermometer will beep and the display will read 188 8 This is a function check indicating the unit is working properly The last measured temperature will be displayed for approximately 2 seconds Next the thermometer will read L F or L C Se The F or C symbol will flash when the unit is ready to measure temperature Please note that the Vz indicates a low battery See instructions for replacing battery before measuring temperature Do not expect an accurate temperature reading if this low battery indicator is present An ERR message in the window indicates your unit is not functioning properly DA Depending on the measurement site the unit will complete measurement in 30 oral 40 rectal or approximately 60 axillary seconds The display will flash and the unit will beep signaling completion on Read and record the temperature and time for reference The reading will automatically be stored in the memory 6 Push the Multi Function button to turn the unit off This will prolong the battery life If you do not turn the unit off it will shut off automatically in approximately 10 minutes Oral use for children 4 years and older 1 Do not drink hot or cold fluids exercise or perform othe
4. f the arm against the body Operation of the F C feature How to change the measuring scale From the OFF position hold down the MULTI FUNCTION button for 5 sec The thermometer will automatically change from F C or C F Release thebutton You may toggle between C and F After 3 sec in one scale the C or F will flash indicating ready to measure Changing the battery When the q appears in the lower right of the display the battery is exhausted and needs re placing Make sure a battery of the same type is on hand and proceed as follows Remove bat tery compartment lid Use a small Phillips screwdriver to remove battery Insert new equivalent battery type 1 55v LR41 or SR41 Ensure battery is correctly positioned with the facing up or towards the back of the unit Carefully replace the battery compartment lid Properly dis pose of the batteries keeping them from small children and heat Standards Complies with EN 12470 3 2000 and ASTEM E 1112 00 The manufacturer recommends a calibration check every 2 years How to care for this product e Use of probe covers is recommended to help avoid spreading germs and to keep the thermometer clean The thermometer should be cleaned after use even when probe covers are used e Clean the thermometer tip and probe only using isopropyl alcohol or soap and water e Store the unit in the protective case while not in use e Do not store or keep i
5. n direct sunlight or in high temperatures e Keep battery away from children e Do not open the thermometer except to replace the battery e Do not drop the thermometer as this may ruin the unit e The manufacturer recommends verifying the accuracy by an authorized laboratory Parts and Assembly RHE Probe Tip Display Window Multi Function Button Specifications Size D L x 3 4 W x 3 8 H 12 7cm L x 1 905cm W x 9525cm H Weight 0 388 oz 11 grams Display LCD Liquid Crystal Display Battery 1 55v LR41 Alkaline Battery Life Estimated 1 500 uses Measurement Time Oral 30 Seconds Rectal 40 Seconds Axillary 90 Seconds Measurement Range 90 0 F to 109 9 F 32 0 C to 43 9 C Accuracy 0 2 F 0 1 C between 96 0 F to 107 0 F 34 0 C to 42 0 C at a room temperature of 64 4 F to 82 4 F 18 C to 28 C Measurement Mode Real measurement with peak hold method Audible Alarm 1 beep at start up Continuous beep at measurement completion Auto Turn Off In approximately 10 minutes Memory Feature Stores last temperature taken Operation Environment 10 C to 40 C 50 F to 104 F Storage Environment 25 C to 55 C humidity of 15 to 95 noncondensing 30 second response time achieved in water bath test WARRANTY This Thermometer is guaranteed for a period of 24 months from date of pur chase This warranty does not cover batteries or damage resulting from improper handling or use
6. r activities that will raise or lower temperature readings when compared to your normal average temperature The mouth should remain closed up to 5 minutes before attempting a reading Figure 2 NO Place the probe tip well under the tongue as indicated Figure 2 oo Instruct children not to bite down on the probe DA The peak temperature should be reached in as little as 30 seconds Opening the mouth or improper placement of the probe tip could result in a longer time for a reading 30 second response achieved in water bath tests Rectal use 1 Commonly used for babies young children or when it is difficult to take an oral or underarm temperature NO After placing the probe cover on the thermometer lubricate with a water soluble jelly or petroleum jelly Se Gently insert the probe tip no more than 1 2 inch or 1 3 cm into the rectum Do not force the tip into the rectum if resistance is encountered DA Dispose of the used probe cover and wash the thermometer as recommended on The peak temperature should be reached in approximately 40 seconds Underarm Axillary use 1 Wipe underarm with a dry towel 2 Place probe tip in armpit and bring arm down against the body 3 The probe should be pointing upward in the same direction as your body if possible 4 The time required for an accurate underarm temperature may be 90 seconds or longer depending on placement of the probe and closure o