Home

600 Series Security Windows

image

Contents

1. nd Min distance from the top of the sill M aminj to the floor mm 15 MODEL 601 603 Before you begin installing your Ready Access Drive Thru Window you must determine what type of installation will be required Example Wood Framing Masonry Framing etc See Chart on page 11 for Masonry and Glazing Rough Opening Sizes The window must be installed square and plumb Installation illustrations are for reference only Construction and local codes will determine the proper installation of the window Contact Ready Access for more information Y ry Rough Opening H Rough Opening Min distance from the top of the sill to the floor 914mm 16 WARNING TWO PEOPLE ARE REQUIRED FOR THE LIFTING AND INSTALLATION OF THE WINDOW 1 Confirm that the customer supplied frame is made to accommodate the dimensions 2 Confirm that AC power has been run and is ready for connection to the window 3 Check shipping carton for any shipping damage and remove window from the carton 4 Check window for any shipping damage NOTE There are two wall mounting applications The mounting space can be surrounded either by sidelights windows or masonry In both cases the upper part
2. STANDARD OPTIONS e 2 standard window dimensions with 3 glass types are available See Chart on Page 9 e Aretrofit kit is available for the Model 600 Single Door Slider that easily upgrades the window from a manual self closing operation to a MOER or fully automatic operation e An inside outside stainless steel shelf is also available Model 601 603 The Model 601 has a moveable Service Panel This offers the option of servicing customers personally The service panel self latches each time it closes and features a deadbolt lock and night security bar for complete security during closed hours The Model 603 has a Stationary Panel In high risk areas the fixed glass allows for ample visibility without the risk of face to face contact An optional full sized S S inside counter available Manual or Electric Operations The Model 601 Single Door Slider helps to keep building costs down by offering the window in a manual self closing or MOER operating styles Or for those who experience heavier traffic an electric operating style is also available Self Closing MOER and Electric models meet health department requirements for self closing units Ease of Operation In a manual self closing operation and MOER the inside attendant pulls the door handle to open the door With a fully automated operation the operator simply steps into the presence sensor and the movable window panel will slide open When the operator steps out of the
3. REVISION OR DRAWN BY SC REVISION DATE 2 13 04 DATE 2 13 04 GAUGE ROUE RES LATEST REVISION NOTE DESCRIPTION A Hanging Hardware Kit PART NO 85183400 43 Ready Access 1815 Arthur Drive West Chicago Illinois 60185 Tel 630 876 7766 Tel 800 621 5045 Fax 630 876 7767 Email ready ready access com Website www ready access com 600 INSTALLATION SERVICE OPERATIONS MANUAL 11 19 08
4. cable drive assembly S hook cable spring chain bearing Replace the defective component Beam Break Lamp is ON and the door open but they do not close Loose or broken wires Secure or Replace the cable assembly Defective electric eye assembly gt Disconnect the cable for the electric eye and press the BEAM TEST button If the door operate properly the eye is defective Replace the eye assembly Defective PCB assembly gt Disconnect the cable for the electric eye and press the BEAM TEST button If the door do not operate properly the PCB is defective Replace the PCB assembly The door closes fully but open back up as soon as the door comes in contact with the frame Loose or broken wires to the limit switches or the PCB assembly Secure or replace the cable assembly Limit switch striker is loose or out of alignment Tighten and or align the striker plate Defective controller unit Replace the controller unit Loose Cable and Chain Tighten the cable pulley 31 Issue Probable Cause Resolution The CLOSE DELAY switch is not working properly Loose or broken connection to the PCB Assembly Secure the cable connector to the PCB assembly or replace the control PCB cover Defective CLOSE DELAY switch Replace the control PCB cover Motor continues to run after the door is fully opened Loose or
5. 601 Service Opening Size passes the California restricted opening requirements 11 MODEL 602 604 47 50 a 4 50 1206mm 7 114mm i 34 75 SO 60 50 883mm 1537mm y 17 00 17 00 432mm 432mm Y Y 432mm 47 50 1207mm i 60 50 153 mm 17 00 432mm MODEL 604 dom Dimensions Height Service Glazing Rough Masonry Rough In Inches Including Opening Size Opening Size Opening Size WxHxD Drawer WxH WxH WxH 47 x 6034 48 x 61 472 x 48 x 17 60 H 20 x 34 Y 1213mm x 1543mm 1219mm x 1549mm 47 34 x 53 48 x 53 4 472 x 35 x 17 5234 H 20 x 27 1213mm x 1346mm 1219mm x 1353mm Model 602 Service Opening Size passes the California restricted opening requirements 12 Safety Information WARNING To avoid the risk of fire Electric Shock or injury to persons observe the following 1 Before servicing or cleaning the unit switch the power off at the mechanical switch near the unit Installed by an Electrician or the electrical entry service panel circuit breaker Load Center switched on accidentally OSHA LOCK OUT TAG OUT procedures are to be observed to prevent power from being 2 Any Installation and or Electrical work must be done by QUALIFIED
6. 85002910 Solenoid and Hook Assy 5 20220003 AC Terminal Block R L 1 85002920 Solenoid and Hook Assy 6 20110281 Micro switch L R 2 Call for 120V Power Supply 7 20200142 Kilrol Pulley 2 Call for 220V Power Supply 8 85001800 Cable and Chain Assy Int l Call for Control PCB Assy Call for Electric Chassis L R 4 Call for Motor w Locked Clutch Call for Electric Chassis R L Call for Motor w Encoder Note For serial s 103800 and older only one micro switch is required up SERIES 600 lt 73 MOTOR AND LOCKING CLUTCH ASSEMBLY 85186800 SERIAL 103800 AND BEFORE All Electric Models Replacement Clutch Assy Part Number 85152700 SERIES 600 MOTOR W ENCODER 83186850 SERIAL 103801 TO PRESENT 36 Lock Latch 85004400 Self Closing 85004300 Electric 85003200 Roller Block Assembly 20220001 85003600 Mounting Block Roller Grove Bearing 85004500 Thumb Turn ho FOR ELECTRIC ONLY 37 20090086 Dead Bolt Lock w Faceplate y 1 O 20090084 Mortise Thumb Turn 20110021 Intercom Speaker 20110020 Phone 20110022 Power Supply 38 600 Security Window 2 3 LATE NIGHT LOCK BAR 601 Security Window 603 Security Window LATE NIGHT LOCK BAR 39 LATE NIGHT LOCK BAR 602 Secu
7. Glazing Model 603 Thermo Pane Smash and Grab Level 1 Glazing Level 3 Glazing Model 604 Thermo Pane Smash and Grab Level 1 Glazing Level 3 Glazing Dimensions 9 4 50 114mm Masonry Rough Opening Size WxH 48 x 44 1219mm x 1118mm Model 600 47 50 1207mm i oe a 34 75 SO 883mm MODEL 600 See Chart for Opening Sizes Dimensions Service Glazing Rough In Inches Opening Size Opening Size WxHxD WxH WxH 472 x 43 x 4 20 x 35 414x438 1213mm x 1111mm 472 x 35 x 4V2 20 x 27 4 47 94 x 36 1213mm x 914mm 10 48 x 36 14 1219mm x 921mm MODEL 601 603 47 50 i 1207mm nti i i 34 75 SO 58 50 883mm 1486mm Y i 17 00 15 00 432mm 381 pu Y Y MODEL 601 a 2 00 432mm 51mm 47 56 AAA 4 T1208mm mi hai i 58 50 1486mm 15 00 Pe Y MODEL 603 17 00 i un 432mm 51mm Dimensions Height Service Glazing Rough Masonry Rough In Inches Including Opening Size Opening Size Opening Size WxHxD Drawer WxH WxH 47 34 x 58 Y 48 x 59 472 x 43V X 42 58 1 2 H 20 x 34 Y 1213mm x 1492mm 1219mm x 1499mm 47 34 x 51 48 x 51 w 472 x 35 x 4 50 34 H 20 x 27 1213mm x 1295mm 1219mm x 1302mm Model
8. broken wires to the limit switches or the PCB assembly Secure or replace the cable assembly Defective Open limit switch Replace the appropriate switch Defective controller unit Replace the controller unit The door does not fully close and goes into AUTOREVERSE to the fully open position Door may be sluggish in operations The CURRENT DETECT lamp will be illuminated before the CLOSE DETECT lamp goes out BEFORE REPLACING THE MOTOR CALL READY ACCESS FOR FURTHER INSTRUCTIONS Spilled soft drink syrup residue is under the door and on the weather stripping of guide block Clean the weather stripping counter and door guides on the bottom of the door with soda water Door are dragging on the counter top Adjust the door height and alignment Refer to the adjustments section of this manual Defective motor assembly gt To test for a defective motor open and close the door with the power OFF If the motor is faulty the red green MOTOR RUN lamp will not illuminate Replace the defective motor assembly Defective CONTROLLER unit Replace the CONTROLLER unit Loose Cable and Chain Tighten the cable pulley The BEAM TEST switch is not working properly The BEAM BREAK lamp is not illuminated and the door does not open Loose or broken connection to the PCB assembly Secure or replace the cable assembly Defective C
9. door open all the way back until the magnet sets Walk out of the sensor beam and the door will release from the magnet and it will self close Relock the deadbolt thumb turn and security lock bar The Automatic Mode is reached by turning ON the main power to the window Stepping in and out of the sensor s range opens and closes the door Automatic Operations Serial 103800 and Before On the controller unit turn the power rocker switch to the ON position Check that the red portion of the rocker switch is visible and that the red power lamp is illuminated Break the electronic eye beam or step into the sensor beam path The red beam break and green motor run lamps go on Step out of the beam path and wait 3 to 6 seconds for the door to close The red motor run lamp and red close detect lamps will illuminate After the door close note that the red power lamp and the current detect lamps are ON If the door does not operate correctly go to the troubleshooting guide in this manual If the door still do not operate properly then call Ready Access at 26 1 800 621 5045 6 The door can be operated manually by pulling the manual release located at the top of the door NOTE Turn the power off to the window to prevent any damage to the PCB Automatic Operations Serial 103801 to Present Hook up power Turn power on Window is ready for normal operation Test and check all operation of the door Observe o
10. of the window above the counter top window sill fits flush with the outside of the wall The illustrations will show the walls with the sidelights as this is the most common application Figure 3 and 4 Figure 3 Figure 4 NOTE If mounting the window in a masonry wall the window mounts flush with the outside finishing of the building Drill points are scribed directly into the masonry The outside edge of the mullion should be flush with the outside finishing of the building See Figure 3 and 4 5 Position the window and place it into the customer supplied frame As shown in Figure 3 and 4 6 With one person holding the window in place level the window using the shim shingles as needed 17 7 Using the window mounting holes as a template drill a quantity of 4 3 16 5mm diameter holes for mounting See Figure 5 AC leads to window R L Mount Flush With The Counter Top Mounting Holes lt A leads to window UR 7 a 3 16 Pilot Holes A __ Pre Diilled Figure 5 AC leads to window R L AC leads to window LIR gt Mounting Straps 8 Take the window back out and drill the mounting holes Set the anchors as needed 9 With one person holding the window in place from the outside set the mounting screws 10 When the window is fully secured seal
11. persons in accordance with all applicable codes standards and manufacturers recommendations and specifications 3 DO NOT insert fingers and or foreign objects into the Drive Thru Window DO NOT block or tamper with the unit in any manner while it is in operation 4 This product must not be used in Potentially Dangerous locations such as Flammable Explosive Chemical laden environment Installation Procedures Tools required to perform the installation e Electric Drill e Metal Drill bits Ye 3mm V4 6mm 1 2 13mm 1 25mm e Screwdrivers Slotted and Phillips e Hacksaw e Jack Utility Knife e Flat File Coarse e Caulking gun e W Nut Driver Materials required for installation Extension Cord Masonry drill bit 14 6mm 1 25mm 1 2 38mm Masonry Hole Saw 1 25mm Channel Lock Pliers Tape Measurer Wire Cutter Step Ladder Level e Window framing architect specified and installed in building Ready Access recommended material is 7s 3mm x 1 9 44 5mm x 4 102mm hollow aluminum tubing or glazing channel e Electrical Tape e Wire Nuts e Caulking silicone Color specific to the color of window e Connectors for conduit as required e Shingle type shims as required to level and plum the window Physical Installation Model 600 Before you begin installing your Ready Access Drive Thru Window you must determine what type of installation will be r
12. presence sensor the movable window panel will automatically close same for the MOER however the magnet will release the door and will self close The range for the presence sensor is adjustable to specific customer needs Security Transaction Drawer Security Transaction Drawer The stainless steel transaction drawer allows for the secure transfer of goods and currency without the risk of personal contact A large 18 5 16 W x 9 1 2 H x 14 9 32 Deep transfer area is large enough for a case of soft drinks while the money clip and change cup allow for the convenient handling of money The drawer automatically locks when closed and has a manual latch lock to prevent break ins when the facility is closed Features level 3 bullet resistance protection Speaker System The pre wired speaker system provides clear communication with customers without the need for face to face contact Quality Construction Anodized aluminum extrusions stainless steel and a selection of glass options combine to give you an attractive secure window that not only enhances building exteriors but will not rust pit or weather Finish This unit is currently available in a clear or bronze anodized aluminum finish or can be powder coat painted in a rainbow of color choices e Fully Assembled Ready to Install Ready Access windows are shipped completely pre assembled and fully glazed for lower installation costs Normal installation takes less than two hours e War
13. silicone or Teflon spray NOTE Do NOT use Grease or Oils Do NOT lubricate the motor clutch assembly Yearly Have a service technician come in and perform a maintenance check on the unit 29 Troubleshooting Guide SERVICE Issue Probable Cause Resolution Power switch in the ON position but the light is not illuminated No power to the controller unit gt Main Circuit breaker is defective or not ON gt The fuse on the power supply is blown gt Main power rocker switch is defective gt AC wiring is defective gt Reset or replace the main circuit breaker in the load center gt Replace the fuse on the power supply gt Test rocker switch with an ohmmeter Replace if necessary gt Check AC wiring for opens Replace if necessary Red Lamp s not illuminating Replace the PCB assembly cover The 4 pin power connector to the main PCB assembly is not secure Secure the connector s to the power supply The connector s to the rocker switch are not secure Secure the connector s to the rocker switch BEAM BREAK lamp is OFF and does not illuminate when the electric eye is broken Defective electric eye assembly gt Pressing the BEAM TEST button on the controller unit can test this The door should open pause and close If the door operate normally check other causes listed below Replace the electric eye assembly Loose electric eye cable
14. the outside of the window to the frame or building using silicone caulk 18 Electrical Installation 10 2003 Chassis Style All power must be connected and wired by a qualified electrician and must be in compliance with all state and local codes The incoming AC power line must be connected to the wires in the duplex box located in the top header Per Standard electrical code The green grounding wire is to be attached to the frame of the unit WARNING Use only 110 120V AC 60Hz source with a dedicated 15A mp circuit International power 220 240V AC 50 60Hz with a dedicated 8amp branch circuit WARNING This must be a dedicated circuit Other electrical equipment must not share the same line from the 15A mp circuit breaker WARNING Turning off the front panel rocker switches does not remove the 110 120 volts of electrical power form the unit WARNING To disconnect the power completely from this unit turn OFF the mechanical switch near the unit Installed by an Electrician or the electrical entry service panel circuit breaker panel Load Center for this unit e OSHA LOCK OUT TAG OUT procedures are to be observed to prevent power from being switched on accidentally 1 Remove the 2 screws holding on the AC access panel Do not remove the slide channel cover 2 Electrician to drill hole in unit as shown Install connector before running power line to unit 1 750 R L MODEL SHOWN 2 500 2
15. to update add or issue a new service manual at any time without notice thereby rendering all previous issues obsolete Please write the Serial Number and Installation Date for your drive thru window in the spaces provided Serial Number Date of Installation The serial number nameplate is located on the post CONTACT INFORMATION FOR SALES AND SERVICE CONTACT Ready Access Tel 630 876 7766 1815 Arthur Drive Tel 800 621 5045 West Chicago Illinois 60185 Fax 630 876 7767 Email ready ready access com Website www ready access com INTRODUCTION The Ready Access window is quality designed to give you years of reliable trouble free service Each window is shipped pre assembled fully glazed and ready for installation All Ready Access windows are thoroughly tested prior to shipping The 600 Series of Single Door Slider Windows are the only completely modular security drive thru system designed to meet your specific security needs With options including a selection of security glazing and four different operating methods this window is adaptable to your level of security needs The Model 600 drive up window comes in four versions manual self closing MOER and a fully automatic electric model The electric version is fully automatic with a manual override in case of a power outage The door will open and close by stepping into an out of the light beam sensor Do not attempt to assist the w
16. 7 DIA HOLE 32 4 500 CONTROL SENSOR AC connection access COVER PANEL panel is opposite the control and sensor panel 19 3 Wire the AC source line to the Terminal Block located in the header of the window AC Terminal Block WIRE TERMINAL BLOCK COLOR CODE RED HOT GREEN GROUND 2 WHITE COMMON NOTE TO GROUND UNIT USE PIGTAIL BY TERMINAL BLOCK THE LINE L1 IS INDICATED BY THE RED TAB AND THE RETURN NEUTRAL IS INDICATED BY THE WHITE TAB ON THE TERMINAL BLOCK FOR PIGTAIL LEADS COMING INTO TERMINAL BLOCK WIRE TIES PROVIDED TO SECURE FREE END OF THE WIRE LEADS TO PREVENT WIRES COMING IN CONTACT WITH MOVING PARTS NOTE USE COPPER CONDUCTORS ONLY 4 Turn ON the power to the unit Load center circuit breaker and power switch on the Control Panel 5 Test window operations See Testing Procedures 20 Initial Window Operation Testing Procedures Action Reaction Turn the power OFF at the rocker switch located on the controller unit Manually open and close the door several times When the door is opening the MOTOR RUN lamp will illuminate green When the door is closing MOTOR RUN lamp will illuminate red The POWER lamp must illuminate during both operations If neither of these lamps illuminate during any of the processes proceed to the Troubleshooting section Turn the power ON at the rocker switch located on the co
17. E CHART 600 Series B DIMENSION RANGE AT 36 FROM FLOOR UNIT HEIGHT DEGREE 0 5 10 15 20 25 43 1 2 1 4 1 2 8 11 1 2 15 19 1 2 35 3 4 B 1 3 1 2 6 9 1 2 12 15 1 2 30 q 3 5 8 10 13 23 Door Alignment Adjustments to the door height and alignment are accomplished by turning one or both of the eccentric nuts located at the top of the doorframe where it mounts to the slide track Figure 7 600 Series Upper Door Channel Figure 7 Adjusting Nuts 24 Calibration The only calibration available on the new style DC 3 PC board is setting the close delay timer using the dip switch package mounted near the ribbon cable connector The CLOSE DELAY TIMER is default set at 3 seconds i Follow the chart below for changing The CLOSE DELAY TIMER is default set a 3 seconds The CLOSE DELAY TIMER settings DIP SWITCH SETTINGS TIME IN SWITCH POSITION SECONDS 1 2737 475 AA100 1 ON OFF OFF OFF OFF CONNECTION SOLENOID 2 OFF _ON OFF OFF OFF CONNECTION 3 OFF OFF ON OFF OFF 4 OFF OFF OFF ON OFF 5 OFF OFF OFF OFF ON MOTOR 12 ON ON OFF OFF OFF CONNECTION 13 ON OFF ON OFF OFF 14 ON OFF OFF ON OFF 15 ON OFF OFF OFF ON 23 OFF ON ON OFF OFF 24 OFF ON OFF ON OFF 25 OFF ON OFF OFF ON 34 OFF OFF ON ON OFF 35 OFF OFF ON OFF O
18. H AA 100 O O 4 Fan Motor A Red y PA JUE J Black ni 271 hr LD S S Relay y 4 3 U A 8 g m f al Latch Solenoid E ES Microswitch UB UE E j vasetti y He Gm fet Of amp amp 8 8 PRESENCE SENSOR cross Detar Hee Dium CES n A T PORER e 6 o JE BEAM TEST CURRENT DETECT NR SWITCH IS LOCATED IN THE CONT ROL PANEL USED IN PRODUCTS DESIGN BY SRH MATERIAL Elec Components WORK TO DIMENSIONS DO NOT SCALE us TOL UNLESS SPECIFIED 600 Series Windows DATE 2 13 04 MATERIAL SPEC m SN XXXX TOL NOT REQ D 7 m ade TOL CLASS 030 REVISION B DRAWN BY SC w CSS ANGULAR TOL 1 REVISION DATE 1 30 09 DATE 2 13 04 GAUGE 1815 Arthur Drive West Chicago IL a 800 621 5045 634 876 7766 Fax 6 0 876 7767 LATEST REVISION NOT E DESCRIPTION o REV B REVISED FLY FAN CONTROL O PTION 600 Series Wiring Diagram PART NO N A Note Serial 4103801 to present 600 Series Windows have 2 Micro switches 42 Appendix A Adjusting or Re hanging the Door The distance of the door s above the mullion or counter top is adjusted by turning the eccent
19. Installation Service Operations Manual 600 Series Security Windows Model 600 Model 601 603 Model 602 604 Pass Thru Window Manual Self Closing MOER Electric TABLE OF CONTENT Topic Page Disclaimer 2 Serial Number Identification 2 Contact Sheet 2 Introduction 3 Product Information 4 Description 4 Specifications 9 Dimensions 10 Safety Information 13 Installation Procedures 13 Tools needed 13 Materials Needed 13 Physical Installation 14 Electrical Installation 19 Initial Operations and Testing 21 Adjustments and Calibrations 22 Operational Procedures Modes of Operation 26 Operations 26 Control Identification Explanation and Function 28 Maintenance Maintenance Schedule 29 Daily 29 Monthly 29 Yearly 29 Service Troubleshooting Guide Cause and Effect 30 Parts Lists Parts List Description Part Number 33 Drawings Exploded Views Schematics 34 Appendix A Adjusting or Re hanging the Door 43 DISCLAIMER READY ACCESS DISCLAIMS ANY LIABILITY FOR ANY DAMAGE OR HARM CAUSED TO THE MODEL 600 DRIVE THRU WINDOW IT S OPERATOR OR ANY OTHER EQUIPMENT HOWEVER CAUSED IF THE MODEL 600 DRIVE THRU WINDOW IS REPAIRED OR SERVICED BY ANYONE OTHER THAN AN AUTHORIZED SERVICE ENGINEER OR CONTRARY TO THE MANUFACTURERS WRITTEN INSTRUCTION CONTAINED HEREIN THIS MANUAL IS INTENDED FOR USE BY THE IN HOUSE OR AUTHORIZED FIELD SERVICE ENGINEERS AND SALES REPRESENTATIVES The manufacturer maintains the right
20. N 45 OFF OFF OFF ON ON MICRO SWITCH SENSOR CONNECTION CONNECTION The DC 2 PCB has 2 Two Potentiometers Window Select Choose settings by window style The WINDOW SELECT DIAL is used to set the type of door configuration for the model of the window Current Adjustment Adjusts the power to the motor The CURRENT DIAL is used to increase or decrease the current to the motor sensetivity This is used to set the auto reverse 25 Operation Procedures Modes of Operation The Model 600 Single Door Slider window has four modes of operation Manual Self Closing MOER and Automatic A ter installation of the Model 600 Manual or Electric Sliding window completion of the testing procedures and the installation of the decorative covers the window is ready for normal use The Manual Mode The opening and closing of the window is done by hand DO NOT OPEN OR CLOSE THE DOOR WITH ANY UNDUE FORCE Manual Operations 4 Unlock the deadbolt and thumb turn on the door drop the lock bar to the open position Release the manual latch and push the door open Push the door closed and allow the manual latch reset On the self closing unit let go of the door and it will self close Relock the deadbolt and thumb turn MOER Manual Open Electronic Release 1 2 3 4 Unlock the deadbolt and thumb turn on the door drop the lock bar to the open position Release the manual latch and push the
21. ONTROLLER unit Replace the CONTROLLER unit Defective PCB assembly Replace the PCB assembly 32 Parts Lists Parts List Description Part Number Description Cable amp Chain Assy New Chassis Cable BEA Sensor to PCB New Chassis Current Part Number 85001800 20112104 Previous Part Number N A N A Note Po Door Assembly Call Manufacturer form part price and availability Door Guide Kit 185003400 IN S Electric Chassis L R CALL FOR N A Provide Serial Electric Chassis R L CALL FOR N A Provide Serial 33 Electric Eye Reflector Kit waist level 85000200 N A Not MOER or 275 after 2 99 Eye Switch Retrofit 84000300 N A Handle Manual Release 600 L R 185002420 N A New Style 2003 chassis Handle Manual Release 600 R L 185002410 N A New Style 2003 chassis Hanging Hardware Kit Adj Nut 2 185183400 65183401 Latch Spring 100650269 N A Lock Dead Lock CALL FOR N A Provide Serial Lock Face Plate CALL FOR N A Provide Serial Lock Mortise Thumb Turn CALL FOR N A Provide Serial Lock Pad CALL FOR N A Provide Serial Lock Self Latch 85004400 N A Lock Thumb Turn 21 19 130 85004600 N A PC Board DC3 CALL FOR N A Provide Serial Power Supply chassis only CALL FOR N A E Power Supply Int l chassi
22. ade Screwdriver and a 1 4 Nut Driver If the drive thru window stays open after the power is turned on and the beam break light is ON the sensor is detecting the floor or the counter top To adjust the presence sensor to the floor 1 Turn the power OFF to the drive thru window 2 Remove one of the plastic end caps from the sensor body Preferably the left side 3 Remove the black plastic lens cover Next to the Right Eye you will see an adjustment dial This dial is used for adjusting the sensor to the distance from the floor The dial is in a clock format The maximum distance is achieved at the 9 o clock position after the right eye clicks back into it s broadest setting The minimum distance is achieved at the 9 o clock position before the right eye clicks back into it s broadest setting NOTE TURN THE DIAL IN A COUNTER_CLOCK_WISE FASHION ONLY E SK 2 cx od y 4 SOT RIGHT EYE LEFT EYE M a a a Y p n T SENSOR WIRE DARK ON OFF ADJUSTMENT UNNECTOR JUMPER SETTINGS DIAL If the Drive Thru window stays open while standing far away from the wall or the window closes on you while you are passing product out to the customer Then the angle of the sensor needs to be adjusted Below are diagrams illustrating the different setting that can be done to adjust the di
23. contact Manual or Electric Operations The Model 602 Single Door Slider helps to keep building costs down by offering the window in a manual operating style Or for those who experience heavier traffic an electric operating style is also available The self closing MOER and electric models meet health department requirements for self closing units Ease of Operation In a manual self closing operation and MOER the inside attendant pulls the door handle to open the door With a fully automated operation the operator simply steps into the presence sensor and the movable window panel will slide open When the operator steps out of the presence sensor the movable window panel will automatically close same for the MOER however the magnet will release the door and will self close The range for the presence sensor is adjustable to specific customer needs Security Transaction Drawer Security Transaction Drawer The stainless steel transaction drawer allows for the secure transfer of goods and currency without the risk of personal contact A large 18 5 16 W x 9 1 2 H x 14 9 32 Deep transfer area is large enough for a case of soft drinks while the money clip and change cup allow for the convenient handling of money The drawer automatically locks when closed and has a manual latch lock to prevent break ins when the facility is closed Features level 3 bullet resistance protection NOTE This drawer is Optional for the Model 602 and Standard o
24. derwriters Laboratories as providing Level 1 9mm handgun protection per UL Standard 752 Model 604 e Level 3 Bullet Resistant Glazing Ideal for high risk businesses and locations Protects against break ins and attacks Glazing is recognized by Underwriters Laboratories as providing Level 3 44 Magnum handgun protection per UL Standard 752 Note Other glazing options available SPECIFICATIONS AND PERFORMANCE MODEL 600 Model Unit Actual Dimensions Weight Number Voltage Unit In Inches In Shipping USA International Amps WXHxD Carton Model 600 110 120 VAC 220 240 VAC 15 A US 472 x 43V2 x 4V2 150 to 450 Ibs 60Hz 50 60Hz 8 A Int l Glass dependant Model 600 110 120 VAC 220 240 VAC 15 A US 475 x 35 x 4V2 150 to 450 lbs 60Hz 50 60Hz 8 A Intl Glass dependant 601 603 110 120 VAC 220 240 VAC 15A US 475 x 43V2 x 4V2 280 to 310 lbs 60Hz 50 60Hz 8 A Intl Glass dependant 601 603 110 120 VAC 220 240 VAC 15 A US 475 x 35 x 4V2 280 to 310 lbs 60Hz 50 60Hz 8 A Intl Glass dependant 602 604 110 120 VAC 220 240 VAC 15 A US 472 x 438 x 17 300 to 410 lbs 60Hz 50 60Hz 8 A Intl Glass dependant 602 604 110 120 VAC 220 240 VAC 15 A US 472 x 3594 x 17 300 to 410 lbs 60Hz 50 60Hz 8 A Intl Glass dependant Glass Options Model 600 Thermo Pane Smash and Grab Level 1 Glazing Model 601 Thermo Pane Smash and Grab Level 1 Glazing Model 602 Thermo Pane Smash and Grab Level 1
25. equired Example Wood Framing Masonry Framing etc See Chart on page 10 for Masonry and Glazing Rough Opening Sizes m 48 819mm ID 3 43 3 4 Milmm gt ID 44 118mm ID ne GLASS STORE FRONT MASONRY WALL DAYLIGHT OPENING ROUGH OPENING 17 10 1 2 43 172 41 1 2 43 1 1 105mm RES Uo 1105mm 4 1060mm ID Y I Minu is 36 iN ci s fr n adt 36 c x the floor to the top or the sil rai 914mm E 914mm 1 f Y E d IAS que ISS NZ n KS EMZRANAT S SII MN LISS ESOS SAN ESG ES PSSS SES OG RRQ a A SSI LS SY SY NN RR SY S E SECTION THROUGH THE SECTION THRDUC GLASS STORE FRONT GH THE MASONRY WALL 14 MODEL 602 604 Before you begin installing your Ready Access Drive Thru Window you must determine what type of installation will be required Example Wood Framing Masonry Framing etc See Chart on page 12 for Masonry and Glazing Rough Opening Sizes The window must be installed square and plumb Installation illustrations are for reference only Construction and local codes will determine the proper installation of the window Contact Ready Access for more information W Rough Opening H Rough Opening
26. from the PCB Secure the cable connector 3 or 4 pin Loose or broken wire s in the electric eye cable Check that the electric eye cables are secure and not broken Defective lamp Replace the PCB assembly cover Defective PCB assembly Replace the PCB assembly The door will not AUTO REVERSE for an obstruction when closing and the motor continue to run The CURRENT DETECT lamp will not illuminate Loose or broken wires to the limit switches or the PCB assembly Secure or replace the cable assembly Defective controller unit Replace the controller unit 30 Issue Probable Cause Resolution When the beam is broken the door does not open The red POWER and BEAM BREAK lights and the green MOTOR RUN light on the CONTROLLER unit are ON Defective motor assembly gt To test for a defective motor open and close the door with the power OFF If the motor is faulty the red green MOTOR RUN lamp will not illuminate Replace the motor assembly Solenoid latch in the door is stuck or defective gt To test for a defective solenoid manually open the door halfway and break the beam The solenoid should retract the hook and the door should open pause and close Break the beam again to verify that the door are not opening gt Check the wiring to the solenoid Replace the solenoid Defective components on the
27. indow manually when in automatic mode damage can occur to internal parts This attractive and economical window is ideal for a drive thru or walk up application The large service opening is suitable for both large and small operations It is available in one standard width 47 2 and two standard window heights 35 34 H and 43 12 H The Model 601 drive up window has a moveable service panel and comes in four versions manual self closing MOER and a fully automatic electric model The electric version is fully automatic with a manual override in case of a power outage The door will open and close by stepping into and out of the light beam sensor Do not attempt to assist the window manually when in automatic mode damage can occur to internal parts The Model 603 has a Stationary Panel In high risk areas the fixed glass allows for ample visibility without the risk of face to face contact These attractive and economical windows are ideal for a drive thru or walk up application The large service opening is suitable for both large and small operations It is available in one standard size 47 gt W x 58 Y2 H x 4 12 D with additional heights available The Model 602 drive up window has a moveable service panel and comes in four versions manual self closing MOER and a fully automatic electric model The electric version is fully automatic with a manual override in case of a power outage The door will open and close by stepping
28. into and out of the light beam sensor Do not attempt to assist the window manually when in automatic mode damage can occur to internal parts The Model 604 has a Stationary Panel In high risk areas the fixed glass allows for ample visibility without the risk of face to face contact These attractive and economical windows are ideal for a drive thru or walk up application The large service opening is suitable for both large and small operations It is available in one standard size 47 Y W x 60 Y H x 17 D with additional heights available An optional full sized stainless steel interior exterior counter is available for most Ready Access windows When used with the READY ACCESS pass thru air curtain system the flush mounted single panel sliding window will provide the crew and customer with comfort during winter AA300 Only and a bug free environment during the summer Heated air curtain is available with 600 and 601 windows only PRODUCT INFORMATION Model 600 e The Model 600 has a moveable Service Panel This offers the option of servicing customers personally The service panel self latches each time it closes and features a deadbolt lock and night security bar for complete security during closed hours e Manual Self Closing MOER or Electric Operations The Model 600 Single Door Slider keeps building costs down by offering the window in a manual self closing or MOER operating style Or for those who experience heavier traffic a
29. n electric operating style is also available Self Closing MOER and Electric models meet health department requirements for self closing units e Ease of Operation In a manual self closing and MOER operation the inside attendant pulls the door handle to open the door With a fully automated operation the operator simply steps into the presence sensor and the movable window panel will slide open When the operator steps out of the presence sensor the movable window panel will automatically close same for the MOER however the magnet will release the door and will self close The range for the presence sensor is adjustable to specific customer needs e Quality Construction Anodized aluminum extrusions stainless steel and a selection of glass options combine to give you an attractive secure window that not only enhances building exteriors but will not rust pit or weather Track free bottom sill provides for a contaminant free surface e Finish This unit is currently available in a clear or bronze anodized aluminum finish or can be powder coat painted in a rainbow of color choices e Fully Assembled Ready to Install Ready Access windows are shipped completely pre assembled and fully glazed for lower installation costs Normal installation takes an average of two to four hours e Warranty and Service Support Your Ready Access window comes with a one year limited warranty on parts and labor provided by a worldwide service organization
30. n the Model 604 Window Speaker System The pre wired speaker system provides clear communication with customers without the need for face to face contact NOTE The speaker system is Optional for the Model 602 and Standard on the Model 604 Window Quality Construction Anodized aluminum extrusions stainless steel and a selection of glass options combine to give you an attractive secure window that not only enhances building exteriors but will not rust pit or weather Finish This unit is currently available in a clear or bronze anodized aluminum finish or can be powder coat painted in a rainbow of color choices e Fully Assembled Ready to Install Ready Access windows are shipped completely pre assembled and fully glazed for lower installation costs Normal installation takes less than two hours e Warranty and Service Support Your Ready Access window comes with a one year limited warranty on parts and labor provided by a worldwide service organization STANDARD OPTIONS e 2 standard window dimensions with 3 glass types are available See Chart on Page 9 e An inside stainless steel shelf is also available GLASS OPTIONS Model 602 e Insulated Glazing Offers thermo pane protection e Impact Resistant Glazing Offers protection against smash amp grab theft and forced entry e Level 1 Bullet Resistant Glazing Offers protection against smash amp grab theft forced entry and gunshots Glazing is recognized by Un
31. ntroller unit Break the electric eye beam to open the door The door will open With the power ON break the electric eye beam momentarily to open and close the door The door will open They will remain in the open position for either approximately 3 0 or 6 0 seconds before closing Default Settings With the power ON press the CLOSE DELAY button located on the controller unit once and break the electric eye beam to open the door The door will open and the length of time that the door remains open will toggle between 3 0 and 6 0 seconds before closing Default Settings With the power ON break the electric eye beam momentarily to open and close the door Insert an object at least 4 101 6mm wide between the door and the frame as the door closes The door will automatically reverse their action the door will open when an object is caught between or restricting the closing of the door 21 Adjustments and Calibrations SuperScan Presence Sensor Adjustment Instruction Once the window is installed and the power is hooked up to the drive thru window unit you will need to test and set the range of the presence sensor This is done to determine the best compatibility for your service applications The presence sensor can be adjusted in many ways to work with different applications The tools required to perform this test and adjustments are Phillips Head Screwdriver Straight Bl
32. p is red and indicates an overload has been detected This lamp may light on opening but Detect Lamp is automatically disabled The lamp will come on when the door is fully closed or when an obstruction has been encountered Beam Test Pressing the BEAM TEST button once will test the operations of the door without using the Switch electric eye or presence sensor To test the operator should not be in the path of the light beam or presence sensor Standing in the light beam while pressing the button will put the window into a test mode This will make the window continuously operate open and close automatically You must turn the power off and back on to reset the window Close Delay Pressing this button will toggle the length of time that the door remains open between 1 5 and 3 0 Switch seconds before closing 28 Maintenance Maintenance Schedule Scheduled maintenance should be performed on a regular basis This is to assure proper operation and performance of the Model 600 windows Daily Check the sill and drawer for foreign materials and or syrup Anything that might cause the window to bind up and not operate smoothly Use warm soapy water or carbonated water to clean the window Monthly Follow safety procedures before opening the unit Check the interior of the unit for any build up of any foreign materials using a dry cloth NOTE KEEP ANY LIQUIDS OFF THE INTERIOR COMPONENTS Clean moving parts and lubricate with
33. peration of window unit being operated by store personnel before leaving Bo mw Each operator must read the operations manual before operating the unit 27 Controls Identification Explanation and Function Controller Unit Lamps and Switches Function Power Lamp This lamp indicates that the power rocker switch is on and the controller is receiving power Motor Run Lamp The MOTOR RUN lamp indicates that power is being applied to the motor When the door is opening lamp will illuminate green When the door is closing the lamp will illuminate red The lamp also allows for the diagnostic checking of the motor and motor wiring To test turn the power OFF at the rocker switch and manually open and close the door This will cause the lamp to illuminate either green or red The POWER lamp must illuminate during both operations If neither of these lamps illuminate during any of the processes proceed to the Troubleshooting section Beam Break Lamp This lamp indicates that the electric eye beam or presence sensor beam has been broken and or the CLOSE DELAY timer is still timing out Close Detect This lamp is red and indicates that a CLOSE sequence has been initiated It will always light Lamp during a door closure and will go out just before the door contacts the frame When the lamp is out the automatic reverse feature is disabled Current This lam
34. ranty and Service Support Your Ready Access window comes with a one year limited warranty on parts and labor provided by a worldwide service organization STANDARD OPTIONS e 2 standard window dimensions with 3 glass types are available See Chart on Page 9 e An inside stainless steel shelf is also available GLASS OPTIONS Model 601 e Insulated Glazing Offers thermo pane protection e Impact Resistant Glazing Offers protection against smash grab theft and forced entry Meets Florida Hurricane Zones e Level 1 Bullet Resistant Glazing Offers protection against smash amp grab theft forced entry and gunshots Glazing is recognized by Underwriters Laboratories as providing Level 1 9mm handgun protection per UL Standard 752 Model 603 e Level 3 Bullet Resistant Glazing Ideal for high risk businesses and locations Protects against break ins and attacks Glazing is recognized by Underwriters Laboratories as providing Level 3 44 Magnum handgun protection per UL Standard 752 Note Other glazing options available Model 602 604 The Model 602 has a moveable Service Panel This offers the option of servicing customers personally The service panel self latches each time it closes and features a deadbolt lock and night security bar for complete security during closed hours The Model 604 has a Stationary Panel In high risk areas the fixed glass allows for ample visibility without the risk of face to face
35. ric nuts located in the corners at the top of each door The exploded view of the assembly is shown in Figure 1 below When a door has dropped such that it impedes the movement of the door it is necessary to re adjust the door to a given distance above the counter top This is accomplished by loosening the two Locking Eccentric Nut combinations at the top of each door Loosening the small locking nuts allows the door to drop down and rest on the counter top Slide the door inward to the closed position and lock using the night lock Insert two shims about 0 100 in thickness under each door One at each end of the door is suggested A standard coffee stir or a tongue depressor is a bout 0 100 thick This allows the door to set at a preset distance off the counter top Starting with one of the Locking Eccentric Nut combinations turn the eccentric nut until you feel resistance and or notice that the door is beginning to rise Keeping the eccentric nut in that position tighten the locking nut down to approximately 30 Ibs in of torque Repeat the above step for each of the remaining Locking Eccentric Nut combinations Remove the shims The door should now be at the proper height as well as being square with each other A H j Accuride Slide We i asher Eccentric Nut Locking Nut WORI USED IN PRODUCTS DESIGN BY SRH MATERIAL Mechanical 131 BO 10 600 Series DATE 2 13 04 MATERIAL SPEC
36. rity Window A 604 Security Window TT M BN REF ID PART NUMBER DESCRIPTION 1 Call for Part Drawer 2 40010030 Bumper 3 Call for Part Adjustment Screw 4 Call for Part Lock Nut 40 2 85183400 HANGING AK HARDWARE E KIT Lae REF PART REF PART ID NUMBER DESCRIPTION ID NUMBER DESCRIPTION 1 See Parts Door Assembly 8 85004500 Latch Lock Thumb Turn List 2 85183400 Hanging Hardware Kit 9 20091180 Latch Lock Electric 3 Cable Clamp 9 85004400 Latch Lock Self Closing 4 66122300 Chain and Micro Switch 10 65103300 Door Handle Bracket 20220001 Mounting Block 11 20090084 Lock Mortise 6 85003600 Roller Grove Bearing Kit 12 20090086 Lock Assembly Dead 1 Bearing w Screws Electric Only Bolt w Faceplate 7 85003200 Roller Block Assembly 41 POWER SUPPLY T RANSFORMER Fly Fan Control Option O O INCOMING 110 120VAC POWER EIS 2 z COMMON Q A POWER swITC
37. s only ICALLFOR amp INA Provide Serial Serial A ELEC Roller Block Replacement Kit 2 Pos 85003200 N A Roller Grove Bearing KIT 85003600 20010030 ROLLER Screw for inside cover sensor striker 10010114 N A Sensor Assy BEA Model 600 85000800 N A Silicone Caulk 8 oz Aluminum 80050029 N A Silicone Caulk 8 oz Bronze 180050020 N A Solenoid 8 Hook Assy for Electric 185002920 IN A Chassis L R Solenoid amp Hook Assy for Electric 185002910 IN A Chassis R L Switch LIMIT FOR CHASSIS 85002200 N A Switch Micro 20110281 N A Wired Switch Cover Champagne 165184703 N A Exploded Views Drawings Page Part Number Description If Applicable 35 N A Header Assembly Exploded View 36 85186800 Motor and Locking Clutch Assembly 36 85152700 Clutch Assembly Exploded View 36 85186850 Motor W Encoder 37 65103500 Roller Block Assembly 37 85004300 4400 Lock Latch Assembly Thumb Turn 38 Me Lock Dead Bolt amp Speaker System 39 N A Window Frame Exploded View 600 601 602 603 604 41 N A Door Assembly Exploded View Schematics 42 N A Electrical Schematic Appendix A 43 N A Adjusting or Re Hanging the Door 34 600 SERIES WINDOWS R L SHOWN SERIAL 4 103801 TO PREBE REF PART REF PART ID NUMBER DESCRIPTION ID NUMBER DESCRIPTION 1
38. stance from the wall 19 DEGREES 20 DEGREES 29 DEGREES 22 To adjust the sensor further or closer to the wall follow the following steps 1 Remove the header cover from the drive thru window frame 2 Disconnect the sensor from the inline connector 3 Remove the 2 4 Hex head screws from the back of the cover that mounts the sensor to the cover 4 Once the sensor has been removed remove I Es is the eye control board from the sensor body Da 5 Position the white plastic clips around the eye control board as illustrated on the previous page 3g Reference the chart below to achieve the proper 250 200 159 109 FRE 50 0c setting that is needed for your application i i 6 Once setting has been determined insert the eye 12 A control board back into the housing Y I 7 Remount the sensor housing onto the cover 8 Reconnect the sensor wires 9 Attach the header cover to the drive thru window RANGE OF SENSOR FROM WALL REFERENCE CHART 600 Series A DIMENSION RANGE WITH 12 DEAD ZONE FROM FLOOR UNIT HEIGHT DEGREE 0 5 109 15 200 250 43 1 2 4 6 4 2 142 148 24 30 1 2 35 3 4 A 1 6 10 16 21 27 30 1 5 1 2 9 14 19 24 RANGE OF SENSOR FROM WALL AT THE WINDOW SILL REFERENC