Home

Ventilconvettori / Fan Coils FO FOH FM FMO Manuale di

image

Contents

1. D Comun Neutre Neutro Neutral Blue Blu Azul Bleu Blau 10 Commutatore 3 velocita Conmutador 3 velocidades 2 EE 2 Drehzablstufen o o O a 2 ua L 14 Bse A 5 Brown lt nu FI oz 2 Blue m 2 G TL 7 Lf o mM ex by Customer charge client a carico cliente cargo cliente DO NOT CONNECT IN PARALLEL DIFFERENT MOTORS NE PAS CONNAITRE EN PARALLELE MOTEURS DIFFERENTS NON COLLEGARE IN PARALLELO MOTORI DIFFERENTI VERSCHLEDENEN MOTOR NICHT PARALLEL VERBINDEN NO ENLAZAR EN PARALELO MOTORES DIFERENTES Mom NOMEFILE Pag 31 38 Collegamenti elettrici del motore ventilatore Fan motor electrical connections Unita serie FM FMO FM units A Low Petite Minima a FM Red Ro EE io Rot gt Medium Movenne Media Mittel Brown Marron Braun 3 i 5 speed switch A High Grande Massima Grosse Came bue oaas PX Black Noire Nero Negro Schwarz a ba NEM Commutatore 3 velocit Comun Neutre Neutro Neutral Conmutador 3 velocidades Blue Blu Az ul Bleu Blau Drehzah stufen r i E C pem N 5 Hi Aru E dh N 1 T
2. valid only for copper wires La caduta di tensione tra macchina funzionante e macchina ferma The voltage drop between operating and non operating unit must deve rimanere sotto al 3 se la caduta di tensione e maggiore del remain below 3 if the voltage drop is greater than 3 a bigger 3 e necessario usare una sezione di cavo superiore wire is required La sezione minima dei cavi deve essere 1 5 mm Minimum cross section of the wires 1 5 mm I COLLEGAMENTI ELETTRICI DEVONO ELECTRICAL CONNECTIONS MUST BE MADE ESSERE ESEGUITI SOLO DA PERSONALE ONLY BY QUALIFIED PERSONNEL AND MUST QUALIFICATO ED IN ACCORDO ALLE VIGENTI ACCOMPLISH THE LOCAL ELECTRICAL AND LEGGI E NORME DI SICUREZZA LOCALI SAFETY CODES AND ORDINANCES SEZIONE MINIMA DEI CAVI DI ALIMENTAZIONE ELETTRICA MINIMUM CROSS SECTION OF THE ELECTRIC SUPPLY WIRES NOMEFILE Pag 22 38 INSTALLAZIONE MECCANICA Scegliere una posizione tale da consentire una buona circolazione dell aria in uscita dal ventilconvettore e dell aria aspirata dal ventilconvettore Non ostruire il flusso dell aria di mandata o di ritorno con oggetti o pannelli Attorno al ventilconvettore lasciare spazio sufficiente per la pulizia e la manutenzione Ogni ventilconvettore deve essere installato in bolla allo scopo di assicurare un buon funzionamento ed un adeguato scarico dell acqua di condensa Per livellare il ventilconvettore regolare i piedini od i tiranti di appensi
3. 38 ELECTRICAL CONNECTIONS General rules BEFORE INSTALLING THE FAN COIL READ CAREFULLY THE WARNINGS AND THE SAFETY RULES ON PAGES 7 E 8 ELECTRICAL CONNECTIONS MUST BE MADE ONLY BY QUALIFIED PERSONNEL AND MUST ACCOMPLISH THE LOCAL ELECTRICAL AND SAFETY CODES AND ORDINANCES BEFORE INSTALLATION BE SURE THAT ELECTRICAL AND HYDRAULIC CONNECTIONS ARE ON OPPOSITE SIDES OF THE APPLIANCE AS AN ALTERNATIVE USE A WATERTIGHT ELECTRICAL BOX USE ONLY COPPER CONDUCTORS FOR WIRING CONNECTIONS THE TERMINAL BLOCKS OF THE FAN COIL ARE DESIGNED TO FIT ONLY COPPER WIRES WIRES MADE OF DIFFERENT MATERIALS I E ALUMINUM MAY OVERHEAT AND SO CAUSE SERIOUS DAMAGES TO THE FAN COIL NOMEFILE segue COLLEGAMENTI ELETTRICI INSTALLARE UN INTERRUTTORE BIPOLARE DI SICUREZZA CHE TOGLIE L ALIMENTAZIONE ELETTRICA AL VENTILCONVETTORE L INTERRUTTORE DEVE AVERE ADEGUATA PORTATA ESSERE FACILMENTE ACCESSIBILE ED IN PROSSIMIT DEL VENTILCONVETTORE AVERE DISTANZA MINIMA TRA I SUOI CONTATTI 3 mm EFFETTUARE I COLLEGAMENTI ELETTRICI IN ACCORDO ALLE VIGENTI LEGGI E NORME DI SICUREZZA LOCALI INSTALLARE E COLLEGARE LA MESSA A TERRA DEL VENTILCONVETTORE PRIMA DI OGNI ALTRO COLLEGAMENTO ELETTRICO EFFETTUARE I COLLEGAMENTI ELETTRICI RISPETTANDO GLI SCHEMI ELETTRICI DEL VENTILCONVETTORE RIPORTATI SUL PRESENTE MANUALE E SU OGNI VENTILCONVETTORE TOGLIERE SEMPRE L ALIMENTAZIONE ELETTRICA PRIMA DI ACCEDERE ALLA MACCHINA Pa
4. All by Customer charge client a carico cliente cargo cliente DO hal i l AS CONNAITRE EN PARALLELE MOTEURS DIFFERENTS TOR SC ILEDENEN MOTOR NICHT PARALLEL VERBINDEN IU 0 ES DIFERENTES Version from 01 2004 va NOMEFILE Pag 32 38 AVVIAMENTO 0 0 1 0 1 1 UC O DOPO L INSTALLAZIONE O DOPO OGNI INTERVENTO DI MANUTENZIONE ESEGUIRE I SEGUENTI CONTROLLI PRIMA DI AVVIARE IL VENTILCONVETTORE Ventilatore gira liberamente Bacinella raccolta condensa pulita e correttamente posizionata Tubi di scarico condensa puliti e funzionanti Tubi di scarico condensa con adeguata pendenza e privi di strozzature e contropendenze Evacuazione acqua di condensa adeguata Sezione tubi acqua adeguata Collegamenti idraulici completati Spurgo aria completato Pressione dell acqua entro i limiti operativi Sezione cavi elettrici adeguata Collegamenti elettrici completati e ben serrati Alimentazione elettrica entro i limiti operativi Collegamenti ai canali completati se unita canalizzata Filtro pulito e montato in posizione Aspirazione dell aria libera da ostacoli e ostruzioni Mandata dell aria libera da ostacoli e ostruzioni START UP AFTER THE INSTALLATION OR AFTER EACH MAINTENANCE MAKE THE FOLOWING CHECKS BEFORE STARTING THE FAN COIL F
5. Installare un interruttore bipolare di sicurezza che toglie l alimentazione elettrica al ventilconvettore l interruttore deve avere adeguata portata essere facilmente accessibile ed in prossimit del ventilconvettore avere distanza minima tra i suoi contatti 3 mm Installare e collegare sempre la messa a terra del ventilconvettore Non depositare materiale infiammabile o polveroso nei pressi dell apparecchio Non togliere le etichette dall interno del ventilconvettore PRESCRIZIONI DI SICUREZZA DURANTE L USO LA MANUTENZIONE LA RIPARAZIONE E pericoloso toccare il ventilconvettore se si hanno parti del corpo bagnate e piedi nudi manomettere i dispositivi di sicurezza e regolazione Spruzzare acqua o liquidi gas infiammabili sul ventilconvettore introdurre oggetti e le mani nelle griglie di aspirazione e mandata dell aria introdurre oggetti e le mani nel ventilatore Non torcere staccare tirare i cavi elettrici che fuoriescono dal ventilconvettore anche se questo disinserito dalla rete di alimentazione elettrica Prima di eseguire interventi di manutenzione riparazione togliere l alimentazione elettrica e assicurare l interruttore in posizione di aperto chiudere le valvole dell acqua attendere che l acqua raggiunga la temperatura ambiente indossare guanti da lavoro Prima di eseguire interventi di manutenzione assicuratevi che l alimentazione elettrica sia disinserita l
6. E MANUTENZIONE Pag 35 38 If the air filter is properly cleaned the coil does not need any maintenance Use a vacuum cleaner in case tha coil need to be cleaned If the coil is very dirty brush between fins with a stif nylon brush BE VERY CAREFUL TO AVOID ANY DAMAGE TO THE FINS OF THE COIL IF THE COIL REMAINS DIRTY OR MAKES A BAD SMELL ASK A SPECIALIZED TECHNICIAN FOR PROPER CLEANING AND MAINTENANCE segue PULIZIA E MANUTENZIONE PRIMA DI QUALSIASI INTERVENTO DI PULIZIA O MANUTENZIONE TOGLIERE L ALIMENTAZIONE ELETTRICA DEL VENTILCONVETTORE follows CLEANING AND MAINTENANCE DISCONNECT ELECTRICAL POWER SOURCE AND SECURE IN DISCONNECTED POSITION BEFORE SERVICING THE UNIT VENTILATORE E MOTORE DEL VENTILATORE FAN AND FAN MOTOR LA MANUTENZIONE DEL VENTILATORE E DEL MOTORE DEVE ESSERE ESEGUITA ESCLUSIVAMENTE DA PERSONALE APPOSITAMENTE ADDESTRATO Almeno una volta all anno e rimuovere eventuali depositi di polvere e sporcizia all interno delle coclee e assicurarsi che il ventilatore sia ben fissato e ben equilibrato I motori non necessitano di alcuna manutenzione in quanto le parti in movimento sono lubrificate a vita NON TENTARE DI LUBRIFICARE LE PARTI DEL MOTORE SI POTREBBERO FORMARE DELLE MORCHIE CHE BLOCCANO COMPLETAMENTE MAINTENANCE OF THE FAN AND THE FAN MOTOR MUST BE CARRIED OUT ONLY BY SPECIALLY TRAINED PEOPLE At least once a year the following operations must be c
7. Tubi Heating Cooling Water Coil 2 Rows 2 Rows 1 3 Rows 10 Tubes Unita orizzontali Horizontal Units Unita verticali Vertical Units 2R 1R 10T 3R 2R 10T 2R 1R 107 1 2 3 4 3 4 3 4 3 4 3 4 3 4 3 4 0 45 0 90 1 38 1 83 2 28 2 73 3 18 3 66 NOMEFILE Pag 19 38 CARATTERISTICHE TECNICHE DEL MOTORE VENTILATORE TECHNICAL CHARACTERISTICS OF THE FAN MOTOR I dati mostrati nelle seguenti tabelle si riferiscono al solo motore del ventilatore e non comprendono alcun accessorio quali ad esempio valvole o resistenze elettriche Data shown in the following tables are valid only for the fan motor and do not include any accessory i e valves or electric heaters Unita serie FO FM FMO FO FM FMO units Numero ventilatori Condensatore pF A an mm mn Number of fans Capacitor uF Power input Ber tee W Unita alta velocit bassa velocit alta velocit bassa velocit Unit size high speed low speed high speed low speed 01 1 NO 76 31 02 1 1 25 78 32 03 1 1 50 79 33 04 1 1 50 118 49 05 1 2 50 120 50 06 1 3 15 121 52 07 1 3 15 122 54 08 2 2 00 230 70 09 2 2 50 230 72 10 2 3 15 232 72 Alimentazione elettrica VAC Power supply VAC min 207 nom 230 max 253 Grado di protezione IP Protec
8. mm minimum cross section Choice proper cross section of the wires Current must be limited to 5 A mm voltage drop between not operating and operating unit must be limited to 3 Wiring Instructions The fan coil has a terminal block that is mounted on the internal side panel on the opposite side to the hydraulic connections The terminal block is ready to be connected to the fan speed selector switch or to the thermostats Both the fan speed selector switch and the thermostats are supplied as accessories and their connection to the unit is shown in the installation instructions supplied with them After the wires have been inserted in the terminal block tighten the screws on each terminal to assure a good electric contact Failure to accomplish this requirement may cause serious danger and possibility of fire NOMEFILE Pag 30 38 Collegamenti elettrici del motore ventilatore Fan motor electrical connections Unita serie FO FOH FO FOH units A Low Petite Minima Kleine FO v Red Rouge Rosso Rojo Rot pani F TE E FCU terminal block Vedium Movenne Media Mittel Brown Marron Braun Bornier V C x i Morsettiera Fan coil High Grande Massima Grosse T nal d Black Noire Nero Negro Schwarz pa in NC tal a 3 speed switch Klemmenleisten Commutateur 3 vitesse
9. nella sua posizione DISCONNECT ELECTRICAL POWER SOURCE AND SECURE IN DISCONNECTED POSITION BEFORE SERVICING THE UNIT The condensate drain pan must be checked before the beginning of the cooling season The condensate drain pan and the discharge hole may clog with scale remove scale withy proper chemical products The condensate drain pan may collect dirt that falls from tha coil and in case of vertical installation TI TIH TIM units may contain foreign materials that fall into the fan coil passing thru the air delivery grill Dirt and scale that are cumulated in tha drain pan may impair the evacuation of condensate water so causing water coming out from the fan coil To clean the condensate drain pan operate as follows e remove the drain pan from its operating position e Clean the drain pan with fresh water e wipe the drain pan carefully e place the drain pan back in its operating position BATTERIA DI SCAMBIO TERMICO HEAT EXCHANGING COIL NOMEFILE Con una adeguata pulizia del filtro la batteria non necessita di manutenzione Per pulire la batteria passare su di essa con un aspirapolvere Se la batteria e molto sporca prima di passare l aspirapolvere spazzolarla con una spazzola in nylon molto morbida FARE MOLTA ATTENZIONE PER NON DANNEGGIARE LE ALETTE DELLA BATTERIA SE LA BATTERIA RIMANE SPORCA OPPURE EMANA CATTIVI ODORI RIVOLGERSI A PERSONALE SPECIALIZZATO PER UNA CORRETTA PULIZIA
10. servomotor with microswitch di fine corsa e termostato and antifreeze thermostat MIXING DAMPER antigelo return spring in case of power only for CPR units chiusura a molla in caso di supply failure mancanza di energia elettrica RISCALDATORI in tubo di acciaio inossidabile stainless steel tubes AISI 304L ELETTRICI AISI 304 L con alette di acciaio with aluminized fins ELECTRIC HEATERS alluminato completi di termostati limite di sicurezza potenza da 0 7 a 5 KW per cadaun elemento con possibilit di collegare piu elementi fra loro alimentazione monofase 230 1 50 con contattori di sicurezza complete with safetv thermostats automatic or manual reset capacitv of each element from 0 7 to 5 kW different elements can be connected together power supplv 230 1 50 with safetv contactors NOMEFILE Pag 8 38 ESECUZIONE ESECUZIONI STANDARD ON DEMAND STANDARD A RICHIESTA CONFIGURATION CONFIGURATIONS VALVOLE DI di tipo on off o modulante on off or modulating valves REGOLAZIONE A 2 E attacco 1 2 o 3 4 Gas M connection 1 2 or 3 4 Gas M VIE montate sul ventilconvettore unit mounted with hydraulic kit complete di kit idraulico 2 AND 3 WAYS CONTROL VALVES KIT RUBINETTI detentori a manopola e a knob valves with handle and chiave key STOP VALVES montati sul ventilconvettore mounted on the unit with completi di kit idraulico hydraulic ki v
11. the circuit assure good operation and long life of the appliance limited energy consumption The piping must be properly sized proper diameter properly insulated to avoid condensate dripping and heat dissipation In general the water inlet is in the lower part of the coil the water outlet is in the upper part of the coil When valves and or stop valves are mounted due to space constraints it may be necessary to put the water inlet in the upper side and the water outlet is in the lower side of the coil Allowed materials for the condensate drain piping are PVC steel In any case after the piping has been connected to the unit tape sealant must be used to prevent water leakages BEFORE INSTALLING THE FAN COIL READ CAREFULLY THE WARNINGS AND THE SAFETY RULES ON PAGES 8 AND 9 PRESSIONE MASSIMA DI ESERCIZIO 2400 kPa 24 bar Pag 24 38 MAX OPERATING PRESSURE 2400 kPa 24 bar NOMEFILE segue COLLEGAMENTI IDRAULICI ASSICURARSI CHE L ACQUA DELL IMPIANTO SIA FILTRATA ESENTE DA SEDIMENTAZIONI CALCAREE O DI OSSIDI DI FERRO CHE POSSONO DANNEGGIARE LA BATTERIA DI SCAMBIO TERMICO E LE VALVOLE DI REGOLAZIONE SE NECESSARIO TRATTARE L ACQUA CON OPPORTUNI PRODOTTI CHIMICI ALLO SCOPO DI PREVENIRE FORMAZIONE DI CALCARE CORROSIONE CRESCITA DI ALGHE FORMAZIONE DI MORCHIE PER L ALLACCIAMENTO DELLA BATTERIA ALL IMPIANTO IDRAULICO USARE SEMPRE CHIAVE E C
12. to your order In case of damages write a description of the damages on the carrier s copy of the shipping documents take pictures of the damages sendi immediatly a letter to the carrier and send a copy to your dealer and or to the manufacturer specifying model and serial number An electric connection 230V single phase and an hydraulic connection to the water chiller boiler are necessary to allow proper working of the appliance The fan coils have been designed for installation in rooms where people live and for heating and or cooling of such rooms the fan coils must be used only for that purpose Each fan coil is checked and tested in the factory and is delivered to the customer only if properly working All repair maintenance operation must be carried out by qualified specialists Failure to observe the rules contained in this manual or any unauthorized modification tamper of the appliance can cause dangerous situations and will immediatly invalidate the warranty of the appliance The manufacturer is not responsible in case of damages caused by unauthorized changes or modifications to the appliance improper installation or improper use NOMEFILE Pag 11 38 NOMEFILE PRESCRIZIONI DI SICUREZZA ALL INSTALLAZIONE II ventilconvettore non deve essere installato all aperto in atmosfere esplosive o in ambienti eccessivamente corrosive umidi in ambienti con molta polvere
13. E H 15 465 15 5 6 E 480 Horizontal furred in units FILTER FRAME FOR DUCTED AIR RETURN goce e grr REAR ENTRY A09 N 18 21 25 30 35 47 59 NOMEFILE Pag 15 38 Modelli orizzontali con mobile Vertical horizontal with cabinet FMO NOMEFILE 11 1040 1240 1440 1640 1840 2040 630 830 1030 1230 1430 1630 720 920 1120 1320 1520 1720 600 800 1000 1200 1400 1600 700 900 1100 1300 1500 1700 34 0 38 5 46 0 52 0 67 0 73 5 80 5 Pag 16 38 Modelli verticali con mobile Vertical units with cabinet FM G de AS e SS LO QM gt Sd SS Ve 170 1840 2040 1740 1940 1400 1600 1480 1680 NOMEFILE Pag 17 38 Batteria ad acqua calda refrigerata 3 Ranghi 10 tubi 1 8 tubi Heating Cooling Water Coil 3 Rows 10 tubes 1 8 tubes Unita orizzontali Horizontal Units Unita verticali Vertical Units NOMEFILE Pag 18 38 Batteria ad acqua calda refrigerata 2 Ranghi 2 Ranghi 1 3 Ranghi 10
14. Non arriva acqua al ventilconvettore Il filtro amp sporco La batteria di scambio termico sporca C aria nel circuito idraulico Il ventilatore non gira o gira in modo non corretto Pag 37 38 TROUBLESHOOTING DISCONNECT ELECTRICAL POWER SOURCE AND SECURE IN DISCONNECTED POSITION BEFORE SERVICING THE UNIT BEFORE ANY CLEANING OR MAINTENANCE OPERATION READ CAREFULLY THE WARNINGS AND THE SAFETY RULES ON PAGES 8 9 10 IN CASEOF FAILURE ASK ONLY TRAINED PEOPLE FOR SERVICING THE UNIT The motor does not rotate at all or does not rotate properly a b c d e No electrical power coming to the fan coil Electrical connections are wrong are not according to the wiring diagrams The fan speed selector switch if installed is in a wrong position The seasonal changeover switch if installed is in a wrong position The setting of the thermostat if installed is wrong The fan coil does not cool heat properly a No water coming to the fan coil The filter is dirty clogged The heat exchanging coil is dirty clogged There is some air into the water circuit The fan dos not rotate at all or does not rotate properly NOMEFILE segue RICERCA GUASTI PRIMA DI QUALSIASI INTERVENTO DI PULIZIA O MANUTENZIONE TOGLIERE L ALIMENTAZIONE ELETTRICA DEL VENTILCONVETTORE II ventilconvettore perde acqua a La batteria di scambio termico rotta b Le connessioni idraul
15. ONTROCHIAVE FARE ATTENZIONE A NON DANNEGGIARE I TUBI IN RAME DELLA BATTERIA INSTALLARE SEMPRE DUE VALVOLE DI INTERCETTAZIONE DEL FLUSSO IDRAULICO UNA ALL INGRESSO ED UNA ALL USCITA DEL VENTILCONVETTORE Pag 25 38 follows HYDRAULIC CONNECTIONS BE SURE THE WATER INSIDE THE CIRCUIT IS FILTERED FREE FROM SCALE OR IRON OXIDES THAT CAN DAMAGE THE HEAT EXCHANGING COIL AND THE VALVES IF NECESSARY WATER MUST BE TREATED WITH CHEMICAL AGENTS IN ORDER TO PREVENT CREATION OF SCALE CORROSION GROWTH OF ALGAE CREATION OF SLUDGE TO CONNECT THE HEAT EXCHANGING COIL TO THE WATER CIRCUIT ALWAYS USE TWO SPANNERS BE CAREFUL AND AVOID ANY DAMAGE TO THE COPPER TUBES OF THE COIL ALWAYS FIT TWO GATE VALVES ON THE WATER CIRCUIT ONE VALVE ON THE WATER INLET OF THE FAN COIL AND ONE VALVE ON THE WATER OUTLET segue COLLEGAMENTI IDRAULICI LE VALVOLE MOTORIZZATE DI REGOLAZIONE DEVONO AVERE SPAZIO SUFFICIENTE PER LO SMONTAGGIO E NON DEVONO ESSERE MONTATE CAPOVOLTE TUBO DI SCARICO CONDENSA 1 CREARE UN SIFONE 2 DARE UNA PENDENZA DI ALMENO 50 mm m 3 NON CREARE CONTROPENDENZE 4 NON CREARE STROZZATURE 5 VERIFICARE GLI ALLACCIAMENTI VERSANDO ACQUA NEGLI SCARICHI DELLA BACINELLA VERIFICA DELL IMPIANTO 1 METTERE L IMPIANTO IN PRESSIONE 2 SFIATARE L ARIA PRESENTE NELLA BATTERIA 3 VERIFICARE ASSENZA DI GOCCIOLAMENTI NON ESEGUIRE L OPERAZIONE PRIMA DEI GIORNI FESTIVI IN MANCANZA DI PE
16. RSONALE DI CONTROLO POTREBBERO VERIFICARSI GRAVI DANNI PER INVERTIRE IL LATO ATTACCHI PROCEDERE COME QUI SOTTO DESCRITTO follows HYDRAULIC CONNECTIONS THE MOTORIZED WATER VALVES REQUIRE PROPER SPACE TO BE REMOVED AND MUST NOT BE MOUNTED UPSIDE DOWN CONDENSATE DRAIN PIPING 1 CREATE A DRAIN TRAP 2 CREATE A MINIMUM SLOPE 50 mm m 3 DO NOT CREATE COUNTERSLOPES 4 DO NOT FLATTEN OR KINK THE PIPE 5 CHECK THE CONNECTION BY POURING WATER INTO THE DRAIN PAN CHECK THE CIRCUIT 1 GIVE HYDROSTATIC PRESSURE 2 AIR VENT THE COIL OF THE UNIT 3 BE SURE THAT NO DRIPPING OCCURS DO NOT CHECK THE CIRCUIT JUST BEFORE A HOLIDAY BIG TROUBLES MAY OCCUR IF QUALIFIED CONTROL PERSONNEL IS NOT ON DUTY TO REVERSE THE WATER CONNECTIONS SIDE PROCEED AS HERE BELOW DESCRIBED NOMEFILE Pag 26 38 segue COLLEGAMENTI IDRAULICI Inversione del lato attacchi togliere il mantello svitando le due viti di fissaggio superiori togliere il pannello comandi se montato svitare le quattro viti superiori della lamiera posteriore togliere il pannello frontale superiore sfliare la batteria anteriormente ribaltare verticalmente capovolgere la batteria di 909 ruotare orizzontalmente la batteria di 1809 rimontare la batteria sul telaio rimontare il pannello frontale e riavvitare le quattro viti posteriori rimontare il pannello comandi se previsto dal lato opposto a quello degli attacchi rimontare i
17. Ventilconvettori Fan Coils FO FOH FM FMO Manuale di installazione uso manutenzione Installation use maintenance manual NOMEFILE Pag 1 38 NOMEFILE LEGGERE ATTENTAMENTE MANUALE I ventilconvettori sono dedicati al riscaldamento ed al raffrescamento di ambienti civili industriali commerciali sportivi essi trovano il loro impiego in numerosi impianti ove sia richiesto uno specifico sistema di distribuzione dell aria e in particolari condizioni funzionali Le destinazioni pi tipiche sono nell edilizia civile appartamenti ville residenze scuole ospedali ecc e commerciale uffici negozi supermercati ristoranti banche ecc Le caratteristiche essenziali di questi ventilconvettori sono elevata pressione disponibile dimensioni esterne contenute facilit di installazione orizzontale o verticale con e senza mobiletto e manutenzione ampia gamma di accessori disponibili Il riscaldamento ed il raffrescamento avvengono tramite circolazione nell apparecchio di acqua rispettivamente calda o fredda Pag 2 38 INDICE INDEX Scopo 2 Application 2 Configurazioni delle macchine 6 Configurations of the appliances 6 Identificazione della macchina 10 Identification of the appliance 10 Ricevimento della macchina 11 Receiving the appliance 11 Avvertenze generali 11 General warnings 11 Prescrizioni di sicurezza all installazione 12 Mandatory safety rules during installation 12 Prescrizioni
18. addizionale per riscaldamento max numero di ranghi 3 2 disponibili batterie ad espansione diretta max pressione di esercizio 2400 kPa 24 bar e max temperatura di esercizio 1209C height 250 mm 2 and 3 rows 200 mm 4 rows tubes 3 8 fins spacing 2 1 mm louvered fins brass connections and number of rows shown in the below table with manual drain and vent Attacchi delle batterie di scambio termico ottone Gas F Heat exchanging coils connections brass Gas F special circuits for best capacity in case of non standard operating conditions additional heating coil max rows 3 2 direct expansion coils max working pressure 2400 kPa 24 bar and max operating temperature 120 C Esecuzione standard Espansione diretta 2 ranghi 3 ranghi 241 341 Standard configuration Direct expansion 2 rows 3 rows 01 015 1 2 1 2 1 2 3 4 1 2 02 025 1 2 3 4 1 2 1 2 3 4 1 2 03 035 1 2 3 4 1 2 1 2 3 4 1 2 04 05 050 1 2 3 4 1 2 1 2 3 4 1 2 06 060 3 4 1 2 1 2 3 4 1 2 07 070 3 4 1 2 1 2 3 4 1 2 08 09 090 3 4 1 2 1 2 3 4 1 2 10 105 3 4 1 2 1 2 3 4 1 2 NOMEFILE Pag 7 38 ESECUZIONE ESECUZIONI STANDARD ON DEMAND STANDARD A RICHIESTA CONFIGURATION CONFIGURATIONS GRUPPO VENTILANTE piastra in acciaio zincato 1 mm motori potenziati per galvanized steel 1 mm thick powered motors for pressure verniciata a polveri epossidiche pr
19. alvola di bilanciamento e balancing valve with key knob detentore a chiave NOMEFILE Pag 9 38 RICEVIMENTO DELLA MACCHINA Ispezionare ogni ventilconvettore consegnato prima di accettarlo Assicurarsi della assenza di deformazioni e o rotture dell imballo Se un imballo appare danneggiato aprirlo immediatamente ed ispezionarne il contenuto prima di accettarlo verificare la carrozzeria del ventilconvettore la batteria di scambio termico la bacinella di raccolta della condensa i filtri la rotazione del ventilatore tutti gli eventuali accessori Non rifiutate la spedizione annotate i danni rilevati sulla bolla di consegna e fotografate i danni rilevati AVVERTENZE GENERALI Questo libretto costituisce parte intergrante del ventilconvettore e deve sempre accompagnare l apparecchio Dopo aver tolto l apparecchio dal suo imballo verificare che non ci siano danni e che l apparecchio corrisponda a quanto ordinato In caso di danni segnalare i danni per iscritto sulla copia della bolla di consegna del trasportatore fotografare i danni inviare immediatamente una lettera al trasportatore ed in copia al proprio rivenditore e o al costruttore citando il modello e la serie Un collegamento elettrico 230V monofase ed un collegamento idraulico con il gruppo frigorifero la caldaia sono necessari per il funzionamento dell apparecchio I ventilconvettori sono destinati al raffrescamento o riscaldame
20. an rotates freely Condensate drain pan free of construction debris other foreign materials and properly positioned Drain lines clean and operating Drain lines with proper slope without counterslope and resctrictions Condensate drain water evacuates properly Adequate cross section of water pipes Piping connections completed Air vent completed Water pressure inside operating limits Adequate cross section of electrical wires Electrical connections completed and tightened Power supply voltage inside the operating limits Duct connections completed ducted units only Filter is free of construction debris other foreign materials and correctly installed Air return flow is free of obstacles and obstructions Air delivery flow is free of obstacles and obstructions NOMEFILE Pag 33 38 PULIZIA E MANUTENZIONE PRIMA DI QUALSIASI INTERVENTO DI PULIZIA O MANUTENZIONE TOGLIERE L ALIMENTAZIONE ELETTRICA DEL VENTILCONVETTORE PRIMA DI QUALSIASI INTERVENTO DI PULIZIA O MANUTENZIONE LEGGERE ATTENTAMENTE LE AVVERTENZE E LE PRESCRIZIONI DI SICUREZZA A PAG 8 9 10 CLEANING AND MAINTENANCE DISCONNECT ELECTRICAL POWER SOURCE AND SECURE IN DISCONNECTED POSITION BEFORE SERVICING THE UNIT BEFORE ANV CLEANING OR MAINTENANCE OPERATION READ CAREFULLV THE WARNINGS AND THE SAFETV RULES ON PAGES 8 9 10 FILTRO Il filtro serve a bloccare corpi estranei sporco polvere pollini ed The function of the a
21. arried out e remove dust and dirt from the inside of the scroll e be sure the fan is properly fixed to the motor and is well balanced The fan motors do not require any maintenance as they are permanently lubricated NO ATTEMPT SHOULD BE MADE TO LUBRICATE THESE PERMANENTLY LUBRICATED MOTORS THE MOTOR MAY BE IL MOTORE CLOGGED BY SLUDGE COLLEGAMENTI Almeno una volta all anno assicurarsi che i morsetti siano ben At least one a year be sure the screws of the terminals are well ELETTRICI serrati tightened ELECTRICAL CONNECTIONS NOMEFILE Pag 36 38 NOMEFILE RICERCA GUASTI PRIMA DI QUALSIASI INTERVENTO DI PULIZIA O MANUTENZIONE TOGLIERE L ALIMENTAZIONE ELETTRICA DEL VENTILCONVETTORE PRIMA DI QUALSIASI INTERVENTO DI PULIZIA O MANUTENZIONE LEGGERE ATTENTAMENTE LE AVVERTENZE E LE PRESCRIZIONI DI SICUREZZA A PAG 8 9 10 IN CASO DI GUASTO PER LA RIPARAZIONE RIVOLGERSI ESCLUSIVAMENTE A PERSONALE APPOSITAMENTE ADDESTRATO Il motore non gira o gira in modo non corretto a b c d e Non arriva alimentazione elettrica al ventilconvettore I collegamenti elettrici sono sbagliati non corrispondono agli schemi elettrici La posizione del commutatore di velocit se installato sbagliata La posizione del commutatore stagionale se installato sbagliata La posizione del termostato se installato sbagliata Il ventilconvettore non raffresca scalda a sufficienza
22. ce Do not remove the labels from the inside of the appliance In case of replacement of components use only spare parts supplied by the manufacturer If the fan coil is installed in very cold climates and a long unoperative period is forecasted the hydraulic circuit must be completely emptied in order to avoid risk of ice inside the tubes ice will cause big damages If a damper for external air is installed the cold air can cause ice inside the tubes of the coil and ice will break the tubes If necessary some glycole must be mixed with the water of the hydraulic circuit The coils are tested up to 3000 kPa 30 bar the maximum allowed operating pressure is 2400 kPa 24 bar the maximum allowed operating temperature is 120 C IN CASE THE AIR FILTER HAS TO BE CLEANED OR CHANGED BE SURE IT IS FITTED AGAIN IN THE APPLIANCE BEFORE RE STARTING THE FAN COIL LIMITI DI IMPIEGO BATTERIA DI SCAMBIO TERMICO E VENTILCONVETTORE minima temperatura del fluido di raffreddamento in assenza di 5 C massima temperatura del fluido di riscaldamento 120 C pressione massima di esercizio 2400 kPa 24 bar alimentazione elettrica tensione minima 207V massima 253V IN CASO DI INSTALLAZIONE IN AMBIENTI DOVE LA TEMPERATURA PUO SCENDERE SOTTO 0 C E NECESSARIO AGGIUNGERE GLICOLE ETILENICO ALL ACQUA SECONDO LA TABELLA SEGUENTE Pag 13 38 OPERATING LIMITS HEAT EXCHANGING COIL AND APPLIANCE minimum tempe
23. di sicurezza durante l uso manutenzione riparazione 12 Mandatory safety rules during use maintenance repair 12 Limiti di impiego 13 Operating limits 13 Smaltimento 14 Waste disposal 14 Masse e dimensioni 15 Masses and dimensions 15 Caratteristiche tecniche del motore ventilatore 20 Technical characteristics of the fan motor 20 Sezione minima dei cavi di alimentazione elettrica 22 Minimum cross section of the electric supply wires 22 Installazione meccanica 23 Mechanical installation 23 Collegamenti idraulici 24 Hydraulic connections 24 Collegamenti elettrici 28 Electrical connections 28 Avviamento 33 Start up 33 Pulizia e manutenzione 34 Cleaning and maintenance 34 Ricerca guasti 37 Troubleshooting 37 Dichiarazione di conformita Declaration of conformity SCOPO APPLICATION PRIMA DI INSTALLARE L APPARECCHIO QUESTO READ CAREFULLY THIS MANUAL BEFORE THE INSTALLATION OF THE APPLIANCE The fan coil units are designed to heat and cool industrial civil commercial sport premises they are specially suitable for a lot of installations where a specific air distribution system or special operating conditions are required The most typical installations are in civil premises apartments villas residence hospitals schools etc and commercial premises offices shops supermarkets restaurants banks etc The main characteristics of these fan coils are high available static pressure limited external dimensions easy installation hori
24. ducts both return and supply sides to avoid transmission of noise and vibrations through the ducts Don not install the fan coil where water dripping inside the appliance may happen Before installation be sure that electrical and hydraulic connections are on opposite sides of the appliance NOMEFILE Pag 23 38 NOMEFILE COLLEGAMENTI IDRAULICI Un corretto allacciamento idraulico ed una adeguata circolazione dell acqua nell impianto assicurano un buon funzionamento ed una lunga durata della macchina un consumo di energia limitato Le tubazioni devono essere di adeguato diametro coibentate per evitare gocciolamenti di condensa e dispersioni di calore Generalmente l ingresso dell acqua si trova sulla parte bassa della batteria e l uscita sulla parte in alto Il montaggio delle valvole e o dei rubinetti puo rendere necessario portare l ingresso sulla parte alta e l uscita sulla parte bassa a causa delle limitazioni di spazio Per le tubazioni di scarico della condensa e possibile usare come alternative tubi in PVC tubi in acciaio In ogni caso dopo aver collegato la tubazione alla macchina sigillare la connessione con nastro allo scopo di prevenire perdite PRIMA DI INSTALLARE IL VENTILCONVETTORE LEGGERE ATTENTAMENTE LE AVVERTENZE E LE PRESCRIZIONI DI SICUREZZA A PAG 8 E 9 HYDRAULIC CONNECTIONS Proper hydraulic connections and proper circulation of the water inside
25. e same temperature of the room wear safety gloves Before any maintenance be sure that the unit is disconnected from the electric power source the water valves are closed the water temperature is not dangerous too hot or too cold NOMEFILE segue PRESCRIZIONI DI SICUREZZA DURANTE L USO LA MANUTENZIONE LA RIPARAZIONE Bambini e persone inabili senza assistenza non devono usare il ventilconvettore Non togliere le etichette dall interno del ventilconvettore In caso di sostituzione di componenti usare sempre ricambi forniti dal costruttore In caso di installazione in climi particolarmente freddi svuotare completamente l impianto idraulico se si prevede un lungo periodo di fermo dell impianto allo scopo di evitare il rischio di gelo nelle tubazioni e conseguenti rotture In caso di installazione con serranda di presa d aria esterna fare attenzione all aria fredda che puo provocare la rottura per gelo dei tubi della batteria Se necessario aggiungere glicole all acqua del circuito Le batterie di scambio termico sono provate a 3000 kPa 30 bar e la massima pressione di esercizio 2400 kPa 24 bar la massima temperatura di esercizio 120 C IN CASO DI PULIZIA O SOSTITUZIONE DEL FILTRO DELL ARIA ASSICURARSI DI RIPOSIZIONARLO NELLA MACCHINA PRIMA DI AVVIARLA follows MANDATORY SAFETY RULES DURING USE MAINTENANCE REPAIR Children or disabled people must not use the fan coil without assistan
26. e valvole dell acqua siano chiuse a temperatura dell acqua non sia pericolosa troppo calda o troppo fredda Pag 12 38 MANDATORY SAFETY RULES DURING INSTALLATION The fan coil must not be installed outdoor in a too humid environment in explosive or corrosive environment ina very dusty environment A bipolar safety switch must be installed to disconnect the appliance from the electric power supply the switch must be properly sized be easily accessible and close to the appliance have a minimum 3 mm distance between its contacts The appliance must be properly connected to an electric earth Do not place flammable dusty goods close to the appliance Do not remove the labels from the inside of the appliance MANDATORY SAFETY RULES DURING USE MAINTENANCE REPAIR It is dangerous to touch the fan coil with wet parts of the body and bare feet to modify or tamper the settings of the safety devices to spray water or flammable liquids gas onto the fan coil to introduce foreign objects or the hands through the air intake and discharge grills to introduce foreign objects or the hands into the fans Do not bend pull detach the electric wires outcoming the fan coil even if it is disconnected from the power supply Before any maintenance repair disconnect electrical power source and secure in disconnected position close the water valves wait until the water is at th
27. ean the filter using a vacuum cleaner e seil filtro troppo sporco e non si riesce a pulirlo sostituirlo e if the filter is too dirty and it s impossible to clean it the filter con uno nuovo must be replaced with a new one RIMONTARE IL FILTRO NEL AFTER CLEANING THE FILTER PLACE THE VENTILCONVETTORE DOPO LA PULIZIA FILTER BACK IN ITS OPERATING POSITION NOMEFILE Pag 34 38 segue PULIZIA E MANUTENZIONE follows CLEANING AND MAINTENANCE BACINELLA DI RACCOLTA DELLA CONDENSA CONDENSATE DRAIN PAN PRIMA DI QUALSIASI INTERVENTO DI PULIZIA O MANUTENZIONE TOGLIERE L ALIMENTAZIONE ELETTRICA DEL VENTILCONVETTORE La bacinella di raccolta condensa deve essere verificata prima dell inizio della stagione estiva La bacinella ed il foro di scarico possono riempirsi di calcare pulire eventuali depositi calcarei con appropriati prodotti chimici La bacinella pu contenere sporco caduto dalla batteria di scambio termico e in caso di installazione verticale TI TIH TIM pu contenere corpi estranei caduti nel ventilconvettore attraverso la griglia di mandata dell aria Lo sporco o il calcare accumulati nella bacinella possono impedire l evacuazione dell acqua di condensa e quindi provocare la fuoriuscita dell acqua dal ventilconvettore Per pulire la bacinella operare come segue e smontare la bacinella dalla sua posizione e pulire la bacinella lavandola in acqua e asciugare bene la bacinella e rimontare la bacinella
28. ecause standrd AUSILIARIA bacinella standard e gia drain pan is already prolonged prolungata a raccogliere la to collect valves condensate AUXILIARY DRAIN condensa delle valvole PAN POMPA DI SCARICO _ di tipo autoaddescante con self priming with control that CONDENSA blocco di rilevazione collegabile can be connected to electric CONDENSATE DRAIN PUMP ad elettrovalvole o allarmi fusibile valves and alarms fuse FILTRO rigenerabile classe G2 spessore efficienza G3 cleanable 10 mm thick G2 G3 efficiency class 10mm COn spessore 25 mm class 25 mm thick FILTER rete di protezione sui 2 lati lavabili protective net on both sides washable in maglia di acciaio zincato galvanized steel mesh in maglia di alluminio aluminum mesh zig zag in alluminio da 20 mm zig zag aluminum 20 mm thick NOMEFILE Pag 6 38 ESECUZIONE ESECUZIONI STANDARD ON DEMAND STANDARD A RICHIESTA CONFIGURATION CONFIGURATIONS BATTERIE DI in Cu Al con alette preverniciate copper tubes and aluminum precoated fins SCAMBIO TERMICO altezza pacco 250 mm per 2e con alette Cu Cu fins copper fins HEAT EXCHANGING COILS 3 ranghi 200 mm per 4 ranghi tubi 3 8 passo alette 2 1 turbolenziate attacchi in ottone e numero ranghi secondo tabella con sfiato e spurgo manuali con circuiti d acqua modificati per ottenere rese ottimali a condizioni diverse da quelle standard batteria
29. eguata sezione limitando la portata a 5 A mm assicurandosi che tra macchina funzionante e macchina ferma la caduta di tensione sia inferiore a 3 Istruzioni per il collegamento Il ventilconvettore dotato di una morsettiera posta sulla fiancata interna dal lato opposto rispetto agli attacchi idraulici La morsettiera gi predisposta per il collegamento al commutatore di velocit o ai termostati Sia il commutatore che i termostati sono forniti come accessori ed il loro collegamento alla macchina e descritto nelle istruzioni con essi fornite Dopo avere inserito i cavi nella morsettiera serrare bene le viti dei morsetti per assicurare un buon contatto elettrico La mancata osservanza di tale prescrizione causa una situazione di grave pericolo con possibilit di incendio follows ELECTRICAL CONNECTIONS ACCESSORIES THAT ARE NOT DESCRIBED IN THIS MANUAL REQUIRE SEPARATE POWER SUPPLY ALL POWER SUPPLIES MUST BE PROPERLY PROTECTED WITH SWITCHES AND FUSES Be sure the voltage is inside the allowed limits see Operating Limits and Technical Characteristics Be sure the electrical circuit upstream the appliance is properly sized to carry the current that is necessary to operate the fan coil see Technical Characteristics and all the other devices already installed or forecasted Minimum cross section of the wires 1 5 mm Wires to the auxiliary circuits switches controls interlocks etc must have 1 5
30. ello Sportellini ispezione Griglia di mandata Filtro A L Griglia Z lt FMO NOMEFILE Pag 5 38 CONFIGURAZIONI DELLE MACCHINE ESECUZIONE STANDARD ESECUZIONI A RICHIESTA CONFIGURATIONS OF THE APPLIANCES STANDARD CONFIGURATION ON DEMAND CONFIGURATIONS PANNELLATURA DEL TELAIO PORTANTE acciaio zincato 1 mm in lamiera zincata e verniciata a polveri epossidiche con spessori di coibentazione galvanized steel 1 mm thick galvanized steel epoxy coated insulated up to 25 mm inside or outside the unit CHASSIS fino a 25 mm interno o thermoacoustic insulation esterno all unit insulation class 0 BS con isolamento termoacustico isolamento in classe 0 BS BACINELLA acciaio zincato verniciato a in acciaio inossidabile galvanized steel epoxy painted stainless steel RACCOGLI polveri epossidiche con scarichi filettati externally insulated with screwed discharges CONDENSA coibentata esternamente con isolamento classe 0 BS polvethilene closed cells 6 mm insulation class 0 BS polietilene a cellule chiuse thick DRAIN PAN spessore 6 mm Class 1 fire proof resistenza al fuoco classe 1 double condensate discharge Y doppi scarico 18 mm per 18 mm for horizontal units and unita orizzontali e 20 mm 20 mm for vertical units per unita verticali BACINELLA non necessaria in quanto la non necessary b
31. evalenze fino a 50 Pa serie epoxy painted up to 50 Pa FOH units or 75 FAN ASSEMBLY uno o pi ventilatori FOH o 75 Pa serie FOHH one or more fans directly Pa FOHH units direttamente accoppiati con coupled with 4 poles motors motori a 4 poli IP 43 IP43 isolamento avvolgimenti in winding insulation F class classe F MOBILE DI in lamiera zincata da 1 a 1 2 in lamiera zincata verniciata in galvanized steel 1 to 1 2 mm galvanized steel painted in any COPERTURA mm verniciata a polveri qualsiasi colore a scheda RAL thick epoxy painted RAL 9010 RAL colour solo per serie FM FMO CABINET only for FM FMO units epossidiche RAL 9010 bianco puro completa di griglia di mandata in PVC colore RAL 7047 completo di griglia di mandata in acciaio verniciato o alluminio anodizzato con isolamento termoacustico di tipo ribassato con ripresa e o mandata frontale con controlli elettromeccanici o elettronici montati sull unita o a muro pure white complete with PVC air delivery grille colour RAL 7047 complete with air delivery grille in painted steel or anodized aluminum with thermoacoustic insulation low profile with front return and or supply with electromechanical or electronic controls mounted on the unit or on a wall SERRANDA DI in acciaio zincato con galvanized steel with gaskets MISCELA solo per guarnizioni di tenuta against air leaks serie CPR servomotore con microswitch
32. g 29 38 follows ELECTRICAL CONNECTIONS A BIPOLAR SAFETY SWITCH MUST BE INSTALLED TO DISCONNECT THE APPLIANCE FROM THE ELECTRIC POWER SUPPLY THE SWITCH MUST BE PROPERLY SIZED BE EASILY ACCESSIBLE AND CLOSE TO THE APPLIANCE HAVE A MINIMUM 3 MM DISTANCE BETWEEN ITS CONTACTS ALL ELECTRICAL CONNECTIONS ARE TO BE MADE IN ACCORDANCE WITH LOCAL ELECTRICAL AND SAFETY CODES AND ORDINANCES THE FAN COIL MUST BE PROPERLY EARTHED MAKE EARTH CONNECTION PRIOR TO ANY OTHER ELECTRICAL CONNECTION FOR WIRING AND INSTALLATION REFER TO THE WIRING DIAGRAM OF THE FAN COIL THAT ARE FITTED ON EACH UNIT AND SHOWN IN THIS MANUAL DISCONNECT ELECTRICAL POWER SOURCE AND SECURE IN DISCONNECTED POSITION BEFORE SERVICING THE UNIT segue COLLEGAMENTI ELETTRICI EVENTUALI ACCESSORI NON DESCRITTI NEL PRESENTE MANUALE RICHIEDONO UNA ALIMENTAZIONI SEPARATE ADEGUATAMENTE PROTETTE DA INTERRUTTORI E FUSIBILI Assicurarsi che la tensione di alimentazione sia entro i limiti prescritti vedere Limiti di impiego e Caratteristiche Tecniche Assicurarsi che l impianto elettrico sia dimensionato per erogare la corrente necessaria al ventilconvettore vedere Caratteristiche Tecniche ed alle altre utenze gi in uso o previste La sezione minima dei cavi deve essere 1 5 mm I cavi di collegamento dei circuiti ausiliari comandi controlli interblocchi etc devono avere sezione minima 1 5 mm Scegliere cavi di ad
33. iche perdono C La bacinella di raccolta condensa sporca e lo scarico ostruito d Il tubo di scarico della condensa ha una inclinazione sbagliata o non ha sufficiente inclinazione e Il tubo di scarico della condensa ostruito Pag 38 38 follows TROUBLESHOOTING DISCONNECT ELECTRICAL POWER SOURCE AND SECURE IN DISCONNECTED POSITION BEFORE SERVICING THE UNIT Water comes out from the fan coil The heat exchanging coil is broken There are some leakages from the hydraulic connections The condensate drain pan is dirty or the discharge hole is clogged The condensate piping has a wrong slope or the slope is not enough The condensate piping is clogged
34. ir filter is to remove foreign matter such as dirt altre impurit che potrebbero venire aspirate all interno del soot pollen and other impurities from the air passing through it FILTER ventilconvettore Said impurities may enter into the fan coil and damage it Si suggerisce di sostituire il filtro almeno una volta all anno la The filter should be replaced once a year the filter should be frequenza di sostituzione deve essere pi elevata in caso di impiego replaced more ferquently if the fan coil is used in a very dirty or del ventilconvettore in ambienti molto sporchi e polverosi dusty environment Tra una sostituzione e la successiva il filtro deve essere mantenuto Between one replacement and the next one the filter has to be pulito kept clean Un filtro sporco non filtra pi l aria ed inoltre A dirty filter does not filter the air passing through it and e penalizza fortemente le prestazioni del ventilconvettore e impairs the operating efficiency of the unit by restricting the air diminuendo il flusso d aria attraverso la batteria di scambio flow over the coil termico e favorisce lo sviluppo di batteri dannosi per l appparato e encourages the growth of bacteria that may be dangerous to respiratorio the health Per pulire il filtro operare come segue To clean the filter please operate as follows e estrarre il filtro dalla sua posizione e remove the filter from its operating position e pulire il filtro con un aspirapolvere e Cl
35. l mantello follows HYDRAULIC CONNECTIONS How to reverse the water connections side remove the cabinet unscrewing the two upper screws remove the control box if mounted unscrew the four upper screws of the rear panel remove the front upper panel remove the coil sliding it from the front side rotate the coil 90 upside down rotate the coil 180 horizontally place the coil back in its position place the front panel back in its positione and fix it with the four rear screws place the control box if any back in position on the opposite side of the water connections place the cabinet back in position NOMEFILE Pag 27 38 COLLEGAMENTI ELETTRICI Prescrizioni generali PRIMA DI INSTALLARE IL VENTILCONVETTORE LEGGERE ATTENTAMENTE LE AVVERTENZE E LE PRESCRIZIONI DI SICUREZZA A PAG 7 E 8 I COLLEGAMENTI ELETTRICI DEVONO ESSERE ESEGUITI SOLO DA PERSONALE QUALIFICATO ED IN ACCORDO ALLE VIGENTI LEGGI E NORME DI SICUREZZA LOCALI PRIMA DELL INSTALLAZIONE ASSICURARSI CHE I COLLEGAMENTI ELETTRICI SIANO DALLA PARTE OPPOSTA RISPETTO AGLI ATTACCHI IDRAULICI IN ALTERNATIVA MONTARE UNA SCATOLA ELETTRICA STAGNA UTILIZZARE ESCLUSIVAMENTE CAVI ELETTRICI IN RAME LE MORSETTIERE DEL VENTILCONVETTORE SONO DISEGNATE SOLO PER CAVI IN RAME CONDUTTORI IN ALTRI MATERIALI ESEMPIO ALLUMINIO POSSONO GENERARE SURRISCALDAMENTI E GRAVI DANNI AL VENTILCONVETTORE Pag 28
36. nto di ambienti solitamente occupati da persone e devono essere utilizzati esclusivamente per questo scopo Il ventilconvettore viene controllato e collaudato in fabbrica e consegnato al cliente funzionante in ogni sua parte Ogni intervento di riparazione o manutenzione del ventilconvettore e dei suoi accessori deve essere eseguito da personale qualificato Il mancato rispetto delle norme contenute in questa pubblicazione qualsiasi modifica non autorizzata qualsiasi manomissione dell apparecchio pu provocare situazioni di pericolo e fa decadere la garanzia Il costruttore non risponde di eventuali danni provocati da modifiche non autorizzate o manomissioni dell apparecchio installazione inadeguata o uso improprio RECEIVING THE APPLIANCE Check every fan coil before accepting it Be sure the packaging is not damaged or bended or broken In case of a damaged package open it immediatly and check the contents before accepting it check the chassis and the panels of the fan coil the hest exchanging coil the condensate drain pan the filters the proper fan rotation all the eventual accessories Do not refuse the shipping please write all the damages on the shipping document and take pictures of the damages GENERAL WARNINGS This manual is part of the fan coil and must always be with the appliance After removing the appliance from the packaging be sure that there are no damages and the appliance corresponds
37. one riferendosi al telaio della macchina Non utilizzare la batteria o la bacinella come riferimento perch sono appositamente inclinate Per evitare la trasmissione di vibrazioni attraverso i muri utilizzare supporti antivibranti Per evitare la trasmissione di vibrazioni attraverso le canalizzazioni dell aria sia di mandata che di ripresa interporre tra l apparecchio e le canalizzazioni opportuni raccordi antivibranti Non installare il ventilconvettore in luoghi dove vi il rischio gocciolamenti di acqua all interno dell apparecchio Prima dell installazione assicurarsi che i collegamenti elettrici siano dalla parte opposta rispetto agli attacchi idraulici MECHANICAL INSTALLATION Choose an area that can allow a proper circulation of the air both incoming to and outcoming from the fan coil Do not place any curtain or any object that can obstruct the unit air outlet and return Adequate clearances around the fan coil are necessary to allow easy access for maintenance and cleaning operations The fan coil must be mounted level to assure proper operation and drainage Level the fan coil by adjusting the supporting feet or the hanging rods level the unit by checking on the unit casing Do not use the coil or drain pan for leveling as they are pitched to provide proper drainage Use shock absorbers supports to avoid transmission of noise and vibrations thru the walls Put shock absorbers between the unit and the air
38. rature of the cooling water without glycole 5 C maximum temperature of the heating fluid 120 C maximum allowed operating pressure 2400 kPa 24 bar electric power supply minimum voltage 207V maximum 253V IN CASO OF INSTALLATIONS WHERE THE TEMPERATURE CAN DROP BELOW 0 C IT IS NECESSARY TO ADD ETHYLENE GLYCOL TO THE WATER ACCORDING THE FOLLOWING TABLE segue LIMITI DI IMPIEGO Il glicole etilenico viene usato per proteggere il circuito dal gelo e prevenire la rottura dei tubi La seguente tabella mostra la percentuale di glicole da aggiungere per ottenere una determinata temperatura di congelamento Massa e viscosita della miscela di acqua e glicole variano in funzione della temperatura e della concentrazione di conseguenza le prestazioni del ventilconvettore ne sono influenzate Il glicole viene solitamente utilizzato anche come inibitore contro la corrosione ed e necessario verificarne la concentrazione almeno una volta all anno follows OPERATING LIMITS Ethylene glycol is used to protect the circuit from freezing and to prevent the tubes to be broken The following table gives the percentage of glycol to add in order to obtain a specific freezing temperature The mix of water and glycol has a specific mass and viscosity which varies depending on the temperature and concentration consequently this affects the capacity of the fan coil Glycol is generally used as an inhibitor of corrosion so it i
39. s necessary to measure its concentration at least once a year Gli imballi i materiali di consumo le parti sostituite vanno smaltite in conformita alle disposizioni di legge in materia di sicurezza e protezione ambientale applicabili nel luogo di installazione Glicole in peso ee aerea Densita Densita Calore specifico Calore specifico e e A a Glycol in weight Glycol in volume a Volume Mass Volume Mass Specific Heat Specific Heat Volume Increase C at 50 C kg dm at 100 C kg dm kJ kg K kJ kg K 0 100 C 5 4 8 0 0 989 0 958 4 18 4 20 4 33 10 9 6 4 1 000 0 970 4 10 4 12 5 00 20 19 4 10 1 012 0 980 3 95 4 05 5 40 30 27 4 17 1 025 0 991 3 81 3 92 5 60 34 33 4 21 1 030 0 994 3 73 3 86 5 85 40 39 6 25 1 037 1 000 3 60 3 78 6 20 44 43 7 30 1 041 1 004 3 50 3 73 6 32 50 49 5 37 1 047 1 010 3 45 3 65 6 50 52 max 51 6 40 1 050 1 012 3 42 3 62 6 51 SMALTIMENTO WASTE DISPOSAL Packaging consumables replaced parts must be disposed according to the local safety laws and environmental protection laws NOMEFILE Pag 14 38 MASSE E DIMENSIONI MASSES AND DIMENSIONS ERE SINTE TETT G Modelli orizzontali E M g 2 p 3 ad incasso 1
40. tion degree IP 43 Classe di isolamento Insulation class F Numero di velocita Number of speed 7 Numero di poli Number of poles 4 NOMEFILE Pag 20 38 Corrente di rotore bloccato A Locked rotor current A NOMEFILE Unita serie FOH FOH units Pag 21 38 1 2 00 78 32 0 71 0 46 0 92 1 2 50 79 33 0 72 0 47 0 94 1 3 15 136 56 0 51 0 32 0 68 1 4 00 137 57 0 51 0 32 0 68 1 4 00 139 59 0 53 0 34 0 71 2 3 15 260 80 0 90 0 54 1 20 2 4 00 265 85 1 02 0 58 1 60 min 207 nom 230 max 253 43 F 7 4 SEZIONE MINIMA DEI CAVI DI ALIMENTAZIONE MINIMUM CROSS SECTION OF THE ELECTRIC ELETTRICA SUPPLY WIRES Le sezioni dei conduttori indicate nelle seguenti tabelle The cross sections of the wires that are shown in the sono following tables are le minime necessarie per l allacciamento alla rete di the minimum required to connect the fan coil to the alimentazione electric supply calcolate per una lunghezza massima di 10 m valid for wires maximum 10 m long calcolate per una portata massima di 5 A mm valid for a maximum current load 5 A mm valide per il solo motore del ventilatore e NON valid only for the fan motor and DO NOT include comprendono alcun accessorio valvole resistenze any accessory valves electric heaters pumps elettriche pompe controlli etc controls etc valide solo per cavi in rame
41. zontal and vertical with and without cabinet easy maintenance big choice of accessories Heating and cooling are given through hot or chilled water that circulates inside the appliance Modelli orizzontali ad incasso FO FOH Horizontal furred in models FO FOH Destinati alle installazioni ove non vi spazio a parete possono essere incassati a These appliances are suitable for installations where no space is available along soffitto the walls the appliances can be furred in or hanged on the ceiling Ducts can be La mandata dell aria puo essere canalizzata installed on the air deliverv La bacinella prolungata in modo da raccogliere la condensa delle valvole non occorre coibentare le valvole o utilizzare bacinelle ausiliarie Modelli orizzontali con mobile FMO Modelli verticali con mobile FM Horizontal models with cabinet FMO Vertical models with cabinet FM NOMEFILE Pag 3 38 Componenti principali Main components telaio portante mobiletto di copertura solo per serie FM FMO griglie di mandata solo per serie FM FMO filtro bacinella di raccolta condensa gruppo ventilatore motore elettrico batteria di scambio termico NOMEFILE Pag 4 38 Mobiletto di copertura e griglie di mandata solo per serie FM FMO Cabinet and air delivery grilles FM FMO series only Pannello porta Filtro Griglia di ripresa griglia posteriore Mant