Home
AWC MP - Stel Welding Division
Contents
1. 1 UR COOLER 2 SCREW M6x16 N 3 SCREW M5x12 4 TROLLEY 5 CAP Safety SCREW M6x16 7 DOOR PANEL 8 B SCREW M5x12 View From A ASSEMBLY SEQUENCE 1_Remove screws M5x12 8 and door panel 7 2_Insert the input cable with plug into the trolley Take it out from the back hole remove first the plastic cap Fasten the input cable with screws M5x12 3 on the back panel see view A IMPORTANT OPERATION 1 Remove the plastic cap 5 2_Once the Cooler is install fasten the safety screw M6x16 6 COOLING LIQUID FILL UP 1_Turn off Cooler and Power Source and remove the cooler plug before filling up with liquid 2 Remove the safety screw 6 3_Pull out the Cooler and fill up with liquid 4_Push back the Cooler and fasten the safety screw 6 13
2. If you want to connect the A W C MP to the single phase mains voltage replace the special ILME 4 WAY plug with an ordinary single phase plug connecting the supply wires and the earth lead to the earth contact AII the operations must have effected from a qualified operator EATHINING To ensure user protection the welding machine must absolutely be correctly connected to the earth system INTERNATIONAL SAFETY REGULATIONS It is indispensable to provide good earthing by means of the yellow green lead in the power cable in order to avoid discharges due to accidental contacts with earthed objects The chassis which is conductive is electrically connected with the earth lead if the equipment is not suitably connected to earth it may cause electric shocks which are dangerous for the user WARNING At the first set up the cooler might have the alarm on because the liquid is not present on the pipes Wait few minutes or tum on and off the cooler few times WARNING If torch is not connected the coller will aways have the alarm on HYDRAULIC CONNECTION Connect the water delivery pipe of the torch to the water output coupling on the A W C MP Connect the water return pipe of the torch to the water input coupling on the A W C MP PRECARIOUS POSITION WARNING If the generator falls it may cause injuries Do not operate or move the generator if it is in a precarious position Do not place the generator on inclined
3. accensione FAWC MP potrebbe segnalare allarme mancanza liquido Questo perche i tubi possono essere vuoti Aspettare qualche minuto affinch il liquido entri in circolo oppure effettuare qualche riaccensione ATTENZIONE Se la torcia non viene collegata PAWC MP da sempre segnale di allarme COLLEGAMENTI IDRAULICI Collegare al raccordo di uscita acqua all A W C MP il tubo di mandata dell acqua della torcia Collegare al raccordo di ingresso acqua all A W C MP il tubo di ritorno dell acqua della torcia AVVERTANZA POSIZIONAMENTO PRECARIO Se il generatore cade pu causare infortuni Non mettere in funzione o spostare il generatore nel caso si trovi in posizione precaria Non posizionare il generatore su piani inclinati superiori a 10 DESCRIZIONE PANNELLO FRONTALE Interruttore Principale Led allarme ottico mancanza circolazione ND A acqua Apparecchio in funzione Uscita acqua fredda tubo blu della torcia Fusibile Segnale acustico mancanza circolazione acqua Ritorno acqua calda tubo rosso della torcia aA N MESSA IN OPERA Eseguire tutti i collegamenti elettrici ed idraulici Azionare l interruttore generale della saldatrice in modo da dare tensione all A W C MP Azionare l interruttore generale portandolo in posizione ON per far funzionare l A W C MP Verificare che l acqua circoli nel circuito idraulico della torcia e ritorni nel serbatoio Controllare pe
4. SCONNECT THE ILME 6 WAY CONNECTOR FROM YOUR WELDING MACHINE DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT electrical Do not dispose of equipment together with normal waste In observance of European MM Directive 2002 96 EC on Waste Electrical and Electronic Equipment and its implementation in accordance with national law electrical equipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility As the owner of the equipment you should get information on approved collection systems from our local representative By applying this European Directive you will improve the environment and human health IN CASE OF MALFUNCTIONS REQUEST ASSISTANCE FROM QUALIFIED PERSONNEL 10 CONNECTION PIN ILME 4 WAY CONNECTOR viewed from GENERATOR SIDE WIRING DIAGRAM PIN 1 and PIN2 Power supply 115 230Vac PIN 1 and PIN3 Power supply 400Vac Earth lead 11 EXPLODED VIEW AND SPARE PARTS 18 N DESCRIPTION CODE 1 Basement 620561 2 Front Label 61129 3 Fuse 64250 4 Red Quick Coupling 63024 5 Blue Quick Coupling 63145 6 7 Fuse Holder 64776 8 Pressure Switch 64777 9 Line Switch 64702 10 11 Radiator 63555 12 Fan 64223 13 Auxiliary transformer 64637 14 PCB 613031 15 16 Power Cable 613062 17 18 19 Pump 64181 20 21 Tank 613034 12 ASSEMBLY INSTRUCTION COOLER
5. STEL MANUALE DI ISTRUZIONE PER GRUPPO DI RAFFREDDAMENTO INSTRUCTION MANUAL FOR LIQUID COOLING SYSTEM AWC MP Info www stelgroup com tel 39 0444 639525 DECLARATION OF CONFORMITY According to The Low Voltage Directive 2006 95 EC The EMC Directive 2004 108 EC The RoHS Directive 2011 65 EU Type of equipment Liquid Cooling System Type of designation 600363000L Awc MP Brand name or trade mark STEL Manufacturer or his authorized representatives established within the EEA Name address phone website STEL s r l Via Del Progresso 59 36020 Castegnero Vicenza Italy Tel 39 0444 639525 Fax 39 0444 639682 www stelgroup it The following harmonized standard in force within the EEA has been used in the design EN 60974 2 Arc welding equipment Part 2 Liquid Cooling System EN 60974 10 Arc welding equipment Part 10 Electromagnetic compatibility EMC requirements Additional information Restrictive use Class A equipment intended for use in locations other than residential By signing this document the undersigned declares as manufacturer or the manufacturer s authorized representative established within EEA that the equipment in question complies with the safety requirements stated above Date Signature Position 01 01 2013 Andrea Barocco General Manager Nine SICUREZZE LO SHOCK ELETTRICO PU UCCIDERE Disconnettere la macchina dalla rete di alimentazione prima di intervenire
6. ber Symbol of the type of welding machine Reference to the construction standards B POWER OUTPUT Symbol of the process Range of the Power Range of the Pressure C POWER SUPPLY Power supply symbol number of phases and frequency Assigned power supply voltage Maximum power supply current Maximum effective power supply current identifies the line fuse D OTHER CHARACTERISTICS Degree of protection INSTALLATION WARNING The good operation of the A W C MP is ensured by correct installation you must therefore proceed as follows Position the machine in such a way that there is no obstacle to the air circulation ensured by the internal fan the internal components require suitable cooling Ensure that the fan does not send deposits or dust into the machine Avoid impacts rubbing and absolutely exposure to dripping water excessive heat sources or any abnormal situations CONNECTION The A W C MP must be connected to your machine by means of the special ILME multi pole plug supplied with the A W C MP Before making the electrical connections between the A W C MP and your generator ensure that the latter is switched off and disconnected from the mains If you want to connect the A W C MP to the three phase mains voltage replace the special ILME 4 WAY plug with an ordinary three phase plug connecting the supply wires to ONLY TWO of the contacts of the plug and the earth lead to the earth contact
7. e puliti completamente prima di procedere alla saldatura ventilare l area potenzialmente infiammabile prima di usare la macchina non usare la macchina in atmosfere che contengano concentrazioni elevate di polveri gas infiammabili o vapori combustibili PREVENZIONE CONTRO SHOCK ELETTRICI Prendere le seguenti precauzioni quando si opera con un generatore di corrente tenere puliti se stessi ed i propri vestiti non essere a contatto con parti umide e bagnate quando si opera con il generatore mantenere un isolamento adeguato contro gli shock elettrici Se l operatore deve lavorare in ambiente umido dovr usare estrema cautela vestire scarpe e guanti isolanti controllare spesso il cavo di alimentazione della macchina dovr essere privo di danni all isolante CAVI SCOPERTI SONO PERICOLOSI Non usare la macchina con un cavo di alimentazione danneggiato necessario sostituirlo immediatamente se c la necessit di aprire la macchina prima staccare l alimentazione Aspettare 5 minuti per permettere ai condensatori di scaricarsi Non rispettare questa procedura pu esporre l operatore a pericolosi rischi di shock elettrico non operare mai con il generatore se la copertura di protezione non al suo posto assicurarsi che la connessione di terra del cavo di alimentazione sia perfettamente efficiente Questo generatore stato progettato per essere utilizzato in ambiente professionale ed indus
8. ent he must take extreme care and wear insulating footwear and gloves check the machine power cable frequently it must be free from damage to the insulation BARE CABLES ARE DANGEROUS Do not use the machine if the power cable is damaged it must be replaced immediately if it is necessary to open the machine first disconnect the power supply Wait 5 minutes to allow the capacitors to discharge Failure to take this precaution may expose the operator to dangerous risks of electric shock never work with the welding machine if the protective cover is not in place ensure that the earth connection of the power cable is perfectly efficient This generator has been designed for use in a professional and industrial environment For other types of application contact the manufacturer If electromagnetic disturbances are found it is the responsibility of the machine user to solve the problem with the technical assistance of the manufacturer 4 ER 5 1 i z ze ct DE PREVENTION OF BURNS To protect your eyes and skin from burns and ultraviolet rays wear dark glasses Wear suitable clothing gloves and footwear use masks with closed sides having lenses and protective glass according to standards degree of protection DIN 10 warn people in the vicinity not to look directly at the arc GENERAL CHARACTERISTICS The STEL cooling unit has been specially studied to obtain maximum performance with STEL mac
9. hines The A W C MP is able to distribute 2 litres min with torch connected with a power of 60W always ensuring perfect operation even when using the torch in extreme conditions The A W C MP has a protection circuit which intervenes in the event of a fault in the cooling system signalling the malfunction the yellow LED lights up on the panel and the acoustic alarm sounds DELIVERY OF THE MATERIAL The package contains N 1 AWC MP N 1 instructions manual Check that all the material listed above is included in the package Inform your distributor if anything is missing Check that the A W C MP has not been damaged in transport If you see any sign of damage consult the COMPLAINTS section for instructions Before working with the A W C MP read this instructions manual carefully COMPLAINTS Complaints for damage during transport If your equipment is damaged during transit you must present a claim to the carrier Complaints for faulty goods All the equipment shipped by STEL is subjected to strict quality control However if your equipment does not work properly consult your authorise dealer TECHNICAL DATA Ve DA Poem 69 Wa GO pur IEC_60974 2 U 240V 1450 60 Hz M max 11 A i U 460V 1450 60 Hz M max 0 65 A 10 A P 218 EEE P l min 0 5 kw pmax 0 35 MPa A IDENTIFICATION Name address of the manufacturer Type of welding machine Identification with reference to serial num
10. io delle apparecchiature dovr informarsi presso il nostro rappresentante in loco sui sistemi di raccolta approvati Dando applicazione a questa Direttiva Europea migliorer la situazione ambientale e la salute umana IN CASO DI CATTIVO FUNZIONAMENTO RICHIEDETE L ASSISTENZA DI PERSONALE QUALIFICATO SAFETY ELECTRIC SHOCK CAN KILL Disconnect the machine from the power line before working on the generator Do not work with deteriorated cable sheaths Do not touch bare electrical parts Ensure that all the panels covering the current generator are firmly secured in place when the machine is connected to the mains Insulate yourself from the work bench and from the floor ground use isolating footwear and gloves Keep gloves footwear clothes the work area and this equipment clean and dry NOISE CAN DAMAGE YOUR HEARING Protect yourself suitably so as to avoid damage FUMES AND GASES CAN DAMAGE YOUR HEALTH Keep your head out of the reach of fumes Provide suitable ventilation of the work area If the ventilation is not sufficient use an exhaust fan that sucks up from the bottom PREVENTION OF ELECTRIC SHOCKS Take the following precautions when working with a current generator keep yourself and your clothes clean do not be in contact with damp or wet parts when working with the generator maintain suitable insulation against electric shock If the operator has to work in a damp environm
11. riodicamente che il livello dell acqua non sia sceso eventualmente rabboccare MANUTENZIONE ORDINARIA L efficienza del A W C MP nel tempo direttamente legata alla frequenza delle operazioni di manutenzione in particolare Per il gruppo di raffreddamento autonomo sufficiente avere cura della sua pulizia interna che va eseguita tanto pi spesso quanto pi polveroso l ambiente di lavoro Sfilare AWC MP dal carrello Togliere ogni traccia di polvere dalla parte interna dell A W C MP mediante getto d aria compressa con pressione non superiore a 3 bar torcia Controllare che tutte le connessioni elettriche siano ben fissate Controllare che tutte le connessioni idrauliche siano ben serrate ed efficienti Non esitare nel sostituire i componenti deteriorati Reinserire AWC MP nel carrello PRIMA DI OGNI INTERVENTO SCONNETTERE LA MACCHINA DALLA RETE PRIMARIA SCOLLEGARE IL CONNETTORE ILME 6 VIE DALLA VOSTRA SALDATRICE SMALTIMENTO APPARECCHIATURE ELETTRICHE ED ELETTRONICHE Non smaltire le apparecchiature elettriche assieme ai rifiuti normali In ottemperanza alla Direttiva Europea 2002 96 CE sui rifiuti da apparecchiature elettriche ed elettroniche e relativa attuazione nell ambito della legislazione nazionale le apparecchiature elettriche giunte a fine vita devono essere raccolte separatamente e conferite ad un impianto di riciclo ecocompatibile In qualit di proprietar
12. ssere collegato alla Vs macchina tramite speciale spina multipolare ILME in dotazione con L A W C MP Prima di effettuare connessioni elettriche tra L A W C MP ed il Vs generatore assicurarsi che quest ultimo sia spento e scollegato dalla rete Se si desidera collegare L A W C MP alla tensione di rete trifase sostituire alla speciale spina ILME 4 VIE una normale spina trifase collegando i fili di alimentazione a SOLO DUE dei contatti della spina ed il conduttore di terra al contatto di terra Se si desidera collegare L A W C MP alla tensione di rete monofase sostituire alla speciale spina ILME 4 VIE una normale spina monofase collegando i fili di alimentazione ed il conduttore di terra al contatto di terra Tutte le operazioni devono essere effettuate da un operatore qualificato MESSA A TERRA Per la protezione degli utenti il generatore dovra essere assolutamente collegato correttamente all impianto di terra NORMATIVE INTERNAZIONALI DI SICUREZZA E indispensabile predisporre una buona messa a terra tramite il conduttore giallo verde del cavo di alimentazione onde evitare scariche dovute a contatti accidentali con oggetti messi a terra Lo chassis che conduttivo connesso elettricamente con il conduttore di terra non collegare correttamente a terra apparecchiatura pu provocare shock elettrici pericolosi per l utente e un non corretto funzionamento del generatore ATTENZIONE Alla prima
13. sul generatore Non lavorare con i rivestimenti dei cavi deteriorati Non toccare le parti elettriche scoperte Assicurarsi che tutti i pannelli di copertura del generatore di corrente siano ben fissati al loro posto quando la macchina collegata alla rete di alimentazione Isolate Voi stessi dal banco di lavoro e dal pavimento ground usate scarpe e guanti isolanti Tenete guanti scarpe vestiti area di lavoro e questa apparecchiatura puliti ed asciutti IL RUMORE PU DANNEGGIARE L UDITO Proteggersi adeguatamente per evitare danni I FUMI ED I GAS POSSONO DANNEGGIARE LA VOSTRA SALUTE Tenere il capo fuori dalla portata dei fumi Provvedere per una ventilazione adeguata dell area di lavoro Se la ventilazione non sufficiente usare un aspiratore che aspiri dal basso WARNING AVERTISSEMENT vietato l utilizzo e l avvicinamento alla macchina da parte di persone portatori di stimolatori elettrici PACE MAKERS PREVENZIONE INCENDI Prendere le seguenti precauzioni per evitare incendi assicurarsi un estintore nell area di saldatura allontanare il materiale infiammabile dalla zona immediatamente vicina all area di saldatura raffreddare il materiale saldato o lasciarlo raffreddare prima di toccarlo o di metterlo a contatto con materiale combustibile non usare mai la macchina per saldare contenitori di materiale potenzialmente infiammabile Questi contenitori devono esser
14. surfaces at an angle of more than 10 FRONT PANEL DESCRIPTION 1 Main Switch 2 Optical alarm led for lack of water circulation 3 Machine live led 4 Cold Water outlet blue tube on the torch 5 Fuse 6 Acoustic signal for lack of water circulation 7 Hot Water return red tube on the torch STARTING UP Make all the electrical and hydraulic connections Turn the main switch of the welding machine so that it feeds the A W C MP Turn the main switch to ON position to make the A W C MP work Ensure that the water is circulating in the hydraulic circuit of the torch and returning to the tank Periodically check that the level of the water has not fallen topping up if necessary MAINTENANCE The lasting efficiency of the A W C MP is directly linked with the frequency of maintenance operations in particular For the cooling unit it is sufficient to keep the inside clean the dustier the working environment the more frequently the inside should be cleaned Take out the AWC MP Remove every trace of dust from the inside of the A W C MP using a jet of compressed air with pressure not higher than 3 bar Check that all the electrical connections are firmly tightened Check that all the hydraulic connections are firmly tightened and efficient Do not hesitate to replace worn components Put in the AWC MP BEFORE ALL OPERATIONS DISCONNECT THE MACHINE FROM THE PRIMARY SUPPLY MAINS DI
15. te le apparecchiature spedite da STEL sono state sottoposte ad un rigoroso controllo di qualit Tuttavia se la Vs apparecchiatura non dovesse funzionare correttamente rivolgetevi al Vs concessionario autorizzato DATI TECNICI Stel srl Ma Del Progreso 8 Wau IEC 60974 2 M max 1 1 A M max 0 65 A A IDENTIFICAZIONE Nome indirizzo del costruttore Tipo generatore Identificazione riferita al numero di serie Simbolo del tipo di generatore Riferimento alla normativa di costruzione B DATI DI POTENZA Simbolo del processo di lavoro Valore della Potenza Valore della Pressione del circuito C ALIMENTAZIONE Simbolo per l alimentazione numero fasi e frequenza Tensione assegnata di alimentazione Massima corrente di alimentazione Massima corrente efficace di alimentazione identifica il fusibile di linea D ALTRE CARATTERISTICHE Grado di protezione INSTALLAZIONE ATTENZIONE Il buon funzionamento dell A W C MP assicurato da una sua adeguata installazione necessario quindi Sistemare la macchina in modo che non sia compromessa la circolazione d aria assicurata dal motoventilatore interno i componenti interni necessitano di un adeguato raffreddamento Evitare che il ventilatore immetta nella macchina depositi o polveri E bene evitare urti sfregamenti ed in maniera assoluta l esposizione a stillicidi fonti di calore o comunque situazioni anomale COLLEGAMENTO LA W C MP deve e
16. triale Per altri tipi di applicazione contattare il costruttore Nel caso in cui disturbi elettromagnetici siano individuati responsabilit dell utilizzatore della macchina risolvere la situazione con l assistenza tecnica del costruttore DESCRIZIONE GENERALE Il gruppo di raffreddamento STEL e stato appositamente studiato per ottenere le massime prestazioni con le macchine STEL L A W C MP infatti in grado di erogare 2 litri min con torcia collegata con una potenza di 60W assicurando sempre un perfetto funzionamento anche usando la torcia in condizioni gravose L A W C MP possiede un circuito di protezione che in caso di anomalia nell impianto di raffreddamento interviene segnalando la disfunzione si accende il LED giallo del pannello e l allarme acustico RICEVIMENTO L imballo contiene N 1 Gruppo di Raffreddamento N 1 manuale istruzione Verificare che siano compresi nell imballo tutti i materiali sopra elencati Avvisare il Vs distributore se manca qualcosa Verificare che il generatore non sia stato danneggiato durante il trasporto Se vi un danno evidente vedere la sezione RECLAMI per istruzioni Prima di operare con il generatore leggere attentamente questo manuale di istruzioni RECLAMI Reclami per danneggiamento durante il trasporto Se la Vs apparecchiatura viene danneggiata durante la spedizione dovete inoltrare un reclamo al Vs spedizioniere Reclami per merce difettosa Tut
Download Pdf Manuals
Related Search
Related Contents
PANDO Manual 2014 INT UL OK METODOLOGIA PARA AVALIAÇÃO E QUALIFICAÇÃO Manual DE Trackspot Special Analog Controller MULTI ENGINE DATA - ULM Technologie GOCLEVER Auto GPS/GPRS t USER MANUAL GOCLEVER BIG Tandberg Data Tandberg LTO2 Network Card User Manual Copyright © All rights reserved.
Failed to retrieve file