1. which may have occurred in shipping If there are damages please contact your dealer immediately 3 2 Setting Up 1 Place the mattress on top of the bed frame Please note for the foot end Mattress can be secured firmly by fixing the elastic straps at the bottom bed frame Warning Please cover the mattress with a cotton sheet to avoid direct skin contact and for patient s comfort 2 Hang the pump onto bed rail foot end and adjust a suitable wideness of hangers 3 Connect air tube connector from air mattress to the pump unit When click is felt or heard the connection is completed and Secured Warning Check and ensure the air tubes are not kinked or tucked under mattress 4 Plug into mains electrical outlet Warning Before inserting the plug into the mains make sure it is suitable for the local main voltage Warning Put the plug into socket of grounded AC power 5 Then turn the main power switch ON The power switch is located on the right side panel of the pump unit Warning Ensure the CPR connectors are sealed completely Grounding Before any connection to the output connectors is made the unit shall be connected to grounding conductor via the three core main cable the grounding is only a functional grounding Installation tips are listed below After installation the extra wire of the power cord if any should be neatly arranged to avoid any tripping accidents The equipment should be firmly placed at posit
2. II peso e le dimensioni del materasso sono state prese senza la gommapiuma Attenzione Le specificazioni sono valide anche per le zone dove c lo stesso voltaggio ITALIANO XX LEVITAS Simbolo BF indica che il prodotto ha un livello della protezione contro scossa elettrica per essere classificato un apparecchio di tipo BF Il simbolo dell apparecchio di Classe II 2 quadrati che indicano che l apparecchio ha un doppio isolamento A Attenzione leggere le istruzioni IPXO Apparecchio chiuso senza protezione contro l entrata dell acqua Il prodotto non deve essere smaltito insieme a rifiuti urbani Pu essere consegnato presso gli appositi centri di raccolta differenziata predisposti dalle amministrazioni comunali Precauzione e avvertenze Attenzione Per ridurre il rischio di scossa elettrica e Staccare sempre la spina immediatamente dopo l uso e Non utilizzare l apparecchio in bagno Non far cadere l apparecchio nell acqua o in altri liquidi e Non cercare di recuperare il prodotto caduto in acqua e staccare immediatamente la spina Avvertenze Per ridurre il rischio di ustioni scosse elettriche incendi o lesioni a persone e Sorvegliare con particolare attenzione l uso del prodotto da su o vicino a bambini ed invalidi e Usare il prodotto solo per l uso indicato nel presente manuale e Non utilizzare accessori non raccomandati dal produttore e Non usare l apparecchio nel caso in cui il filo o la presa siano danneggia
3. Tasto fa Funzione Power Premere per accendere il sistema Per gonfiaggio completo del materasso sono necessari circa 15 minuti Le installazioni standard sono per il ciclo in modalita alternato di 5 minuti la pausa di rotazione 10 minuti Allarm Mute Attiva e disattiva l allarme sonoro Premere il tasto per disattivare l allarme sonoro L allarme suoner di nuovo se dopo 3 minuti la pressione non ancora tornata ai livelli normali Panel Lock Fissa le impostazioni scelte e ne impedisce il cambiamento Per riattivare il pannello tenere il bottone premuto per 3 secondi Low Pressure Indicator Indica il livello di pressione del materasso Spia spenta condizione normale il materasso pu essere usato normalmente Spia gialla la pressione non ha raggiunto il livello installato gialla lampeggiante la pressione bassa Autofirm Assicura il massimo gonfiaggio del materasso Tutte le funzioni sono disattivate fino a che questo bottone viene premuto di nuovo Questo ciclo dura per 20 minuti dopo di che torneranno automaticamente le impostazioni prestabilite Static Interrompe il ciclo alternato di gonfiaggio del materasso trasformandolo in materasso normale Premere di nuovo per riavviare il ciclo alterno Seat Inflate gonfiaggio posizione seduta La pressione aumenta nella zona d appoggio del corpo per dare maggior comfort mentre il paziente seduto e per agevolare l alzarsi dal letto Disattivare questa funz
4. in due cartoni separati per assicurare il fissaggio dei contenuti Aprire i colli per rimuovere la pompa e il materasso Controllare la pompa e il materasso per eventuali danni causati dal trasporto Se gli oggetti sono danneggiati contattare immediatamente il rivenditore 3 2 Installazione Posizionare il materasso su di un piano ai piedi del letto in modo che i raccordi per la connessione dei tubi dell aria siano posizionati verso i piedi del letto II materasso pu essere legato ai piedi del letto con dei lacci elastici Attenzione Coprire il materasso con lenzuola di cotone per evitare il contatto diretto con la pelle del paziente 2 Attaccare la pompa al letto e aggiustare la larghezza dei ganci 3 Connettere il tubo di collegamento ai connettori della pompa La connessione completa ed assicurata quando si sente un click Attenzione Controllare che i tubi non siano piegati sotto il materasso 4 Collegare la spina alla presa elettrica Attenzione Prima di attaccare la spina alla presa elettrica controllare che i dati riportati sull apparecchio siano conformi alla vostra rete elettrica Attenzione Collegare la spina solo alla presa con messa a terra AC 5 Portare l interruttore in posizione ON L interruttore situato sul lato destro del pannello della pompa Attenzione Assicurarsi che i connettori CPR siano sigillati accuratamente ITALIANO 4 Operazioni Nw LEVITAS 4 1 Descrizione delle funzioni
5. livello prestabilito del gonfiaggio raggiunto quando si spenge l indicatore della pressione di gonfiamento basso Low Pressure Indicatore Ora pu essere usato il materasso Attenzione Per verificare che il livello di gonfiaggio adatto stato ottenuto inserire il palmo della mano tra un elemento gonfiato e il corpo del paziente Il contatto con il paziente dovrebbe essere minimale 4 5 Sgonfiaggio Emergenza Per sgonfiare il materasso in caso di emergenza disconnettere semplicemente il connettore posizionato nella sezione di testa del materasso per sgonfiare velocemente le prime 4 celle Il materasso rimane in funzione tranne la sezione sgonfia Per gonfiare di nuovo le celle attaccare il connettore ed aspettare alcuni minuti 4 6 Gonfiaggio posizione seduta Seat Inflate La pressione nella zona d appoggio del corpo aumenta per dare il comfort mentre il paziente seduto e per agevolare l alzarsi dal letto Disattivare questa funzione quando il paziente si sdraia di nuovo per evitare la pressione troppo alta nella zona del corpo 4 7 Funzione Protezione dei talloni Ultime celle del materasso sono costruite per proteggere i talloni del paziente riducendo la pressione 4 8 Allarme pressione bassa Low Pressure Quando si verificato uno stato di pressione insolitamente bassa per un periodo prolungato si accende un allarme visivo LED giallo lampeggiante e sonoro Controllare che tutte le connessioni siano sicure e installate corr
6. MA LTM 630 01A N LEVITAS Distribuito da Distribuited by Moretti S p A Via Bruxelles 3 Meleto 52022 Cavriglia Arezzo Telefono 39 055 96 21 11 Fax 39 055 96 21 200 www morettispa com info morettispa com e LTM630 NEOPRO 10000 MANUALE D ISTRUZIONE NEOPRO 10000 INSTRUCTION MANUAL Prodotto da Produced by Apex Medical Corporation Taipei Taiwan Rappresentante in Europa EU Representative APEX MEDICAL S L Alameda de Reaclde 50 Despacho 304 48008 Bilbao Vizcaya Spain ITALIANO xA LEVITAS sistemi terapeutici della Serie Neo sono conformi alla Direttiva 93 42 EEC e sono stati sottoposti alle procedure della verifica conformit stabiliti dalla direttiva Codice LTM620 Grazie per aver acquistato il materasso antidecubito e pompa della linea LEVITAS by Moretti fabbricata secondo i pi alti standard di qualit e sicurezza e conforme alla direttiva europea sui dispositivi medici 93 42 CEE LEGGERE ATTENTAMENTE IL MANUALE PRIMA DELL USO Destinazione d uso prevenzione e trattamento delle piaghe da decubito 1 Informazioni generali sistemi terapeutici della serie Neo sono prodotti usando le tecnologie e i materiali d avanguardia per garantire la migliore qualit il massimo comfort e la minor rumorosit possibile La maggior parte dei sistemi terapeutici della serie Neo sono raccomandati per la prevenzione e il trattamento delle piaghe da decubito incluse quelle di IV grado sistem
7. ave proper position while reducing the interface pressure at the heel region only available in 10 mattress model 4 8 Low Pressure and Alarm Function When an abnormal low pressure is lasted for a long period the Low Pressure Indicator flashing yellow LED will light up with audible alarm Check if all the connections are securely made and that they are correctly installed as per installation instructions Warning If the pressure level is consistently low check for any leakage at air cells or connecting N LEVITAS ENGLISH tubes If necessary replace any damaged cells or tubes or contact local qualified dealer for repair If the control unit is equipped without audible alarm feature the Low Pressure Indicator will flash until the low pressure fault condition is solved If the control unit is equipped with audible alarm feature the Low Pressure indicator will flash and the alarm will sound when air pressure is below normal preset pressure To silent the alarm simply press the alarm mute button and it will be silent for 3 minutes however the Low Pressure Indicator still remains flashing After 3 minutes alarm buzzer will alert again if the pressure has not yet returned to normal 5 Cleaning Warning Ensure the pump unit is disconnected from the mains before cleaning 5 1 Pump Unit Wipe with a damp cloth and a mild detergent and keep it away from dust If other detergent is used choose one that will have no chemical effects on the
8. ble setting When the Low Pressure indicator is off it indicates the mattress has reached to its preset softness Patient can lie on the mattress Warning Check to see if the suitable comfort range or pressure setting is selected by sliding one hand between the deflated air cell and the patient to feel the patient buttock Users should be able to feel the minimal contact 4 5 Intubation Function To activate the emergency intubation simply disconnect the connector located at the head section to quickly deflate the first 4 air cells The whole mattress will still function normally except at this region To make mattress back to normal simply secure the connector and wait for a few minutes for inflation only available in models of 10 and 8 mattress 4 6 Seat Inflate Function When it is necessary for patient to sit on the bed or for easiness of getting in and out of mattress the seat inflate function provide extra pressure compensation in body region s cells for more suitable surface support only available in models of 10 and 8 mattress This function should be disable when user is in lying position to prevent too high pressure support at body zone 4 7 Heel Protection Function The last 5 air cells of mattress are interchangeable with a set of 5 and 18 air cells to provide a proper heel protection The 5 air cell provides the heel protection and 18 air cell provides the foot stopper These integrated air cells help patient to h
9. ccessfully approved to the following standards EN 60601 1 UL 2601 EN 60601 1 2 EN 55011 Class B EN 60555 2 Class A EN 60555 3 EN 50141 IEC 1000 4 4 IEC 1000 4 5 IEC 1000 4 2 1 2 Intended Use This product is an advanced alternating pressure relief replacement system suitable for highrisk patients This low air loss system is intended to help and reduce the incidence of pressure ulcers while optimizing patient comfort It is recommended for prevention and treatment of pressure ulcers up to stage IV 2 The Product The digital controlled pump unit which provides adjustable pressure and cycle time is compact and effective in pressure control and management The replacement mattress which offers a low air loss therapy provides patients a comfortable pressure support suiting for each individual The patented cell in cell design allows the inflation and deflation of air cells to be achieved in the shortest amount of time while providing the good pressure dispersion The inner cell also offers a sufficient weight support during a power failure the cell in cell bladder design is only available in models of 10 and 8 mattress 2 1 Product Description 1 Mattress 2 Pump unit 3 Air tube connector 4 Control panel ENGLISH xA LEVITAS 3 Installation 3 1 Unpacking The pump unit and mattress are packaged in a separate box to secure its contents inside Unpacking these boxes to remove the pump unit and mattress and check for any damage
10. dles on both sides of air tube connector into the pump unit slightly before push the connector into the pump unit e Make sure the connector is tightly secured by hearing click while pushing it into pump unit No air produced from some e This is normal since there are alternating and rotating mode air outlets of the air tube connector Air outlets take turn to produce air during their preset cycle time If your questions can t be answered with above information please contact your local agent directly They might require a technician to take care the problem 9 Technical Description Pump Specification Power supply AC100 120V 50 60Hz AC220 240 50 60Hz Fuse Rating 1A TIA Dimension LxWxH 37 x 27x 13 cm or 14 4 x 10 5 x 5 0 Weight 6 0 kg or13 2 Ib Environment e Temperature Operation 10 50 Storage 10 70 Shipping 10 70 e Humidity Operation 30 75 non condensing Storage 10 100 non condensing e Atmosphere 700 hPa 1060 hPa Classification e Class Il Type BF Applied Parts Mattress e Not suitable for use in the presence of a flammable anesthetic mixture e IPXO Enclosed equipment without protection against ingress of water e Continuous operation Mattress Specification e Dimension inflated LxWxH 200 x 90x 25 4 cm 78 7 x 35 4 x 10 e Weight 10 kg or22 Ib The weight and dimension of mattress is measured without foam Warning The specifications also apply tothose areas operatingwith the samepower
11. ettamente secondo le istruzioni d uso Se necessario sostituire gli elementi e i tubi danneggiati e contattare il rivenditore locale autorizzato ad effettuare le riparazioni Nel caso il panello di controllo non sia completo di allarme sonoro l allarme visivo Low Pressure pressione bassa lampegger finch la pressione non torner al livello prestabilito Se il panello di controllo completo di allarme sonoro il lampeggiare dell allarme visivo viene accompagnato da quello sonoro ITALIANO gt LEVITAS Per spegnere l allarme sonoro premere il bottone ALLARM MUTE L allarme sonoro di Low Pressure continuer a lampeggiare L allarme suoner ogni 3 minuti finch il livello di pressione non tornato ai livelli prestabiliti 5 Pulizia Attenzione Verificare che la pompa sia disconnessa dalla spina prima di iniziare le pulizie 5 1 La pompa Strofinare con panno umido e detergente neutro Tenere lontano dalla polvere Se viene usato un detergente non neutro verificare che il detergente scelto non abbia degli effetti chimici con la superficie plastica della pompa Lasciare asciugare completamente prima dell uso Attenzione Non immergere nell acqua o bagnare la pompa 5 2 Materasso Lavare con acqua calda e detergente neutro La coperta pu essere lavata con sodio ipoclorite diluito in acqua Lasciare asciugare completamente all aria aperta prima dell uso Non usare prodotti a base di fenolo Attenzione Se il livello di pres
12. i terapeutici delle serie Neo sono stati collaudati da enti indipendenti risultando conformi ai seguenti standard EN 60601 1 UL2601 EN 60601 1 2 EN 55011 Class B IEC 801 2 IEC 801 3 IEC 801 4 IEC 801 5 EN 61000 3 2 EN 61000 3 3 1 2 Uso consigliato NeoPro 10000 un sistema terapeutico a bassa perdita d aria destinato a prevenire la formazione delle pieghe da decubito e ad ottimizzare il comfort del paziente Consente di regolare la pressione in funzione delle singole parti del corpo individuali ed consigliato per la prevenzione e la cura delle piaghe da decubito fino alla IV grado 2 Il Prodotto Il sistema terapeutico NeoPro 10000 formata da una pompa a controllo digitale che permette di regolare sia la pressione sia la durata del ciclo in modalit alternata Il materasso che offre la terapia a bassa uscita d aria permette un riposo comodo riducendo la pressione e regolandola secondo le esigenze individuali Originale design cella dentro cella permette il gonfiaggio e lo sgonfiaggio delle celle d aria pi velocemente e garantisce l efficace dispersione della pressione La cella interna garantisce anche il supporto sufficiente del peso in caso dell interruzione del flusso della corrente 2 1 Pompa e materasso 1 Materasso 2 Pompa 3 Connettore del tubo d aria 4 Pannello di controllo A LEVITAS ITALIANO ND Pompa e materasso B 3 Installazione 3 1 Disimballo La pompa e il materasso sono imballati
13. ion where users doctors can easily access Nw LEVITAS ENGLISH 4 Operation 4 1 Function Description Control Button Function Description Power To turn on control unit It takes approximately 15 min to inflate the mattress The default settings are 5 min alternating cycle time level 1 comfort level 10 min flat level pause interval and 4 min turn level pause interval Allarm Mute Enable and disable the audible alarm feature Press this button to silent the audible alarm The alarm buzzer will alert again after 3 min if the pressure has not yet returned to normal condition Ta Panel Lock To lock the current setting and prevent other persons from changing them To unlock the panel press this button and hold it for 3 seconds Low Pressure Indicator 3 Conditions 1 No light normal condition mattress is operated accordingly 2 Yellow light pressure has not reached the preset setting 3 Flashing yellow light low pressure condition Autofirm For maximum inflation of mattress All other functions are disabled unless this button is pressed again This mode will last for 20 min and then it will return to default setting automatically A Static lo For non alternating mode of mattress To go back to alternating mode simply press this button again such as regular air mattress Seat Inflate Lal The Body zone s pressure will be increased higher than the preset setting to give a proper support for purpose
14. ione quando il paziente si sdraia di nuovo per evitare che la pressione sia troppo alta nella zona del corpo Comfort Range Gamma comfort Ci sono 6 livelli di comfort Usare tasto UP DOWN per scegliere il livello dal 1 pi morbido al livello 6 pi duro Cycle Time Ciclo alternato Ci sono 4 livelli del ciclo alternato Usare tasto UP DOWN per scegliere il livello della durata del ciclo di 5 10 15 oppure 20 minuti A LEVITAS ITALIANO 4 2 Istruzioni d uso 1 Premere l interruttore POWER nel display per avviare il sistema 2 Per rendere il gonfiamento pi veloce attivare la funzione AUTOFIRM premendo il pulsante Il ciclo dura 20 minuti dopo che il ritorno alle installazioni iniziali automatica 3 Terminato il gonfiaggio l operatore pu cambiare le installazioni secondo raccomandazione medica 4 3 CPR Le valvole CPR vengono attivate per uno gonfiaggio immediato del materasso in caso di interventi di rianimazione urgenti Tali valvole sono situate sul lato destra della testa del materasso connettori dei tubi d aria possono essere disconnessi dal materasso per uno sgonfiamento ancora pi veloce 4 4 Ciclo alternato di gonfiaggio Il livello di pressione del materasso pu essere aggiustato secondo 6 livelli diversi premendo il bottone sul pannello di controllo Inoltre il sistema dotato di cicli alternati di varia duratura 5 10 15 e 20 minuti Per scegliere l impostazione pi adatta consultare il medico Il
15. mamente agli elementi con i bottoni e le cinghie e Controllare che il materasso sia attaccato fermamente al letto Il connettore del tubo d aria e Premere leggermente i manici del connettore prima di connetterlo non si attacca alla pompa alla pompa e Assicurare di aver attaccato il connettore alla pompa fermamente Un click dovrebbe essere sentito per la verifica Non funziona l alternanza e Aspettare l inizio del ciclo di rotazione completo visto che il materasso di gonfiaggio potrebbe essere nella fase Flat level o nella pausa di rotazione Se il problema incontrato con il prodotto non stato elencato qui sopra contattare il vostro rivenditore per la risoluzione del problema 9 Caratteristiche tecniche Pompa Caratteristiche Alimentazione AC100 120V 50 60Hz AC220 240 50 60Hz Classe Fusibile 1A TIA Dimensioni Lunghezza x 37 x 27 x 13 cm Larghezza x Altezza Peso 6 0 kg Condizioni di funzionamento e Temperatura Operativit 10 C 50 C Magazzinaggio 10 C 70 C Trasporto 10 C 70 C e Umidit Operativit 30 75 non condensato e Atmosfera Magazzinaggio 10 100 non condensato 700 hPa 1060 hPa Classificazione Classe Il tipo BF IPXO Non adatto ad essere usato nella presenza dei anestetici infiammabili IPXO Apparecchio chiuso non protetto contro l entrata d acqua Operazione continua Materasso Caratteristiche Modello Dimensioni sgonfio LxWxH Peso LTM630 200 x 105 x 25 4 10 kg
16. manufacturer e Never operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Return the product to a service center for examination and repair e Keep the cord away from heated surfaces e Never block the air openings of this product or place it on a soft surface such as a bed or couch where their openings may be blocked Keep the air opening free of lint hair and other similar particles e Never drop or insert any object into any opening or hose e Connect this product to a properly grounded outlet only eThis device is Class Il equipment with functional earth no Protective Earth is provided GARANZIA Tutti i kit materasso antidecubito a bolle e compressore Serie Neo sono protetti da una garanzia di 24 mesi per ogni eventuale difetto di fabbricazione La garanzia non copre guasti forature o malfunzionamenti derivanti da un cattivo uso od installazione del prodotto e parti soggette ad usura e deterioramento L apparecchio verr riparato o sostituito gratuitamente a giudizio della Moretti S p A purch venga inviato tramite il rivenditore fiduciario dove stato effettuato l acquisto franco di porto e accompagna to dalla presente garanzia debitamente compilata WARRANTY All kit mattress antidecubitus and pump Serie Neo sets are guarantied for 24 months against any possible manufacturing fault The warranty covers neither damages per forations o
17. r bad functioning caused by mishandling or faulty installation nor parts sub ject to wear and tear Postage must be paid and the appliance must be sent together with the present guarantee coupon duly filled in Distribuito da Distribuited by Moretti S p A Via Bruxelles 3 Meleto 52022 Cavriglia Arezzo Telefono Telephone 39 055 96 21 11 Fax 39 055 96 21 200 www morettispa com info morettispa com A LEVITAS CAMORETTI LEVITAS CERTIFICATO DI GARANZIA WARRANTY CERTIFICATE Prodotto Product Acquistato in data Purchasing date Rivenditore Authorized dealer Via Street Localit Place Venduto a Purchased by Via Street Localit Place
18. replace air filter regularly if the environment is dirty This will help to improve the airflow Spare filters are available from the local distributers 7 3 Fuse Replacement 1 Disconnect the plug form mains power when a fuse is to be replaced 2 Remove the cover of the fuse holder by means of a small screwdriver 3 Insert a new fuse of the correct rating in and replace the cover of the fuse holder back Check the technical specification for correct fuse rating ENGLISH xA LEVITAS 8 Troubleshooting Problem Solution Power is not ON e Check if the plug is connected to mains e Check if there is any blown fuse Alarm is on audible amp visual e Check if the connection between air tube connector to pump unit is tightly secured e Check if all tubing connections along mattress are secured e Check if the CPR is sealed e Check if there are any leakage on air cells Patient is bottoming out Pressure setting might be inadequate for the patient adjust comfort range 1 to 2 levels higher and wait for a few minutes Mattress becomes too firm e The AUTOFIRM is activated for too long release some air by and pressure can t be lower down disconnecting the air tube connector and change to your preferred setting Mattress form is loose e Check if all the snap buttons and straps of mattress on all air cells are all securely fastened e Check if the mattress is fixed to the bed frame by elastic straps Air tube connector can t fit e Press han
19. s of user s sitting up and easiness of getting in and out of the mattress This function should be disable when user is in lying position to prevent too high pressure support at body zone only available in 10 and 8 mattress models Comfort Range 6 Comfort ranges of mattress Use UP DOWN button to adjust the comfort levels 1 is the softest amp 6 is the firmest Cycle time 4 Alternating cycle time Use UP DOWN button to adjust the cycle time of 5 10 15 20 minutes ENGLISH xA LEVITAS 4 2 Operating Instruction 1 Press the POWER button on the display panel to start the system 2 For faster inflation the AUTOFIRM function can be activated This mode will last for 20 minutes and then it will return to default setting automatically 3 After the mattress is fully inflated user can change the setting according to their preference or recommended by physician 4 3 CPR When there is an emergency to perform CPR on the patient quickly pull the CPR valves to release air from mattress The CPR valves are located at the head end right hand side of the mattress The air tube connector located on the pump unit indicated with PULL CPR sign can be disconnected for even faster deflation 4 4 Alternating Function Setup User can adjust pressure of air mattress by adjusting the comfortable range from level 1 to 6 The system also provides various alternating cycle time mode 5 10 15 20 minutes Please consult your physician for a suita
20. sione costantemente bassa verificare che non ci siano delle fessure negli elementi o nei tubi connettori Consultare il distributore per un detergente adatto in vendita nel paese d acquisto Attenzione Asciugare il materasso all ombra 6 Magazzinaggio e conservazione 1 Staccare le valvole CPR e sgonfiare il materasso affinch tutte le celle siano completamente sgonfie 2 Stendere il materasso capovolto 3 Proteggere l accoppiatore dei tubi d aria infilandoli dentro il materasso 4 Arrotolare il materasso cominciando dalla testa 5 Infilare le cinghie nei piedi del materasso intorno al materasso per fissarlo 7 Manutenzione 7 1 Generale e Controllare la spina e il filo per verificare che non siano eccessivamente consumati e Controllare che la coperta del materasso non presenti segni di usura o danneggiamenti e Verificare che i tubi siano staccati correttamente dal materasso e Controllare il connettore del tubo d aria per eventuali danni e Informare il produttore o il distributore per qualsiasi danno rilevato 7 2 Sostituzione del filtro d aria Il filtro d aria dovrebbe essere controllato e spolverato periodicamente e Staccare la coperta plastica situata nel retro della pompa e Il filtro riutilizzabile e pu essere lavato con l acqua e detergente neutro e Nel caso la pompa venga usata in un ambiente particolarmente polveroso consigliabile cambiare il filtro d aria regolarmente Questo aiuta a migliorare il fl
21. supply x BF symbol indicatethis product isaccording to thedegree of protectingagainst electric shock fortype BF equipment E The Symbol for class Il equipment 2 concentricsquare indicating doubleinsulation A Attention shouldread the instructions IPXO Enclosed equipment withoutprotection against ingressof water Disposal of Electrical amp Electronic Equipment WEEE This product should be handed over to an applicable collection point for the recycling of electrical and electronic equipment For more detailed information about the recycling of this product please contact your local city office household waste disposal service or the retail store where you purchased this product Nw LEVITAS ENGLISH Important safeguard Warning To reduce the risk of electrocution e Always unplug this product immediately after using Do not use while bathing e Do not place or store product where it can fall or be pulled into a tub or sink e Do not place in or drop into water or other liquid e Do not reach for a product that has fallen into water Unplug immediately Warning To reduce the risk of burns electrocution fire or injury to persons e This product should never be left unattended when plugged in Close supervision is necessary when this product is used by on or near children or invalids e Use this product only for its intended use as described in this manual e Do not use attachments not recommended by the
22. surface of the plastic case of the pump unit All parts should be air dried thoroughly before use Warning Do not immerse or soak pump unit 5 2 Mattress Wipe down with warm water containing a mild detergent The cover may also be cleaned using sodium hypochlorite diluted in water All parts should be air dried thoroughly before use Do not use Phenolic based products for cleaning For suitable and locally available cleaner please ask your distributor Warning Dry the mattress on SUNLESS capitalized area after cleaning 6 Storage e Pull the CPR tags and make sure all cells are deflated Lay the mattress out flat and upsides down e Protect the air tube coupler by putting it in the inner side of mattress Roll the mattress from the head end towards the foot end Foot end straps can then be stretched around the rolled mattress to prevent unrolling 7 Maintenance 7 1 General e Check main power cord and plug if there is abrasions or excessive wear e Check mattress cover for signs of wear or damage Ensure mattress cover and tubes are stubbed together correctly e Check the air tube connections for any damage Report any problems or malfunctions to local distributors 7 2 Air Filter Replacement The air filter should be checked and dusted periodically e Snap out the plastic cover located on the back of the pump unit e The filter is reusable and can be washed gently with a mild detergent and water e Suggest to
23. ti non funzioni correttamente sia caduto danneggiato o bagnato Nei casi sopra citati si prega di rinviare il prodotto al distributore per eventuali verifiche e o riparazioni e Tenere il filo di alimentazione lontano da fonti di calore e Non bloccare le uscite d aria dell apparecchio e non posarlo su superficie morbide quali letto divano dove le uscite d aria potrebbero essere bloccate Tenere le uscite d aria libere da polvere capelli e similari e Non inserire oggetti nelle aperture presenti sull apparecchio e Collegare il prodotto ad una appropriata connessione elettrica A LEVITAS ENGLISH The Serie Neo is in conformity with the Medical Devices Directive 93 42 EEC and has been subjet to the conformity assurance procedures laid down in the Council Directive Codes LTM630 Thank you for purchasing the mattress antidecubitus and pump LEVITAS by Moretti which have been manufactured according to the highest quality and safety standards 93 42 CEE MPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING Use for antidecubitus treatment 1 1 General Information Neo series systems use most advanced technologies and mattress materials to deliver the best quality comfort and whisper quiet operations to you and your customers Most systems in Neo series are recommended for prevention and treatment of pressure ulcers up to and including stage IV pressure ulcers The Neo series range of systems have been independently tested and su
24. usso d aria filtri di ricambio possono essere acquistati dai distributori locali 7 3 Sostituzione del fusibile e Staccare la presa dalla spina prima di cambiare il fusibile e Staccare il coperchio del portafusibili con un cacciavite piccolo e Inserire il nuovo fusibile controllando che la classe del fusibile sia quella indicata nelle descrizioni tecniche A LEVITAS ITALIANO 8 Risoluzione dei problemi Problema Soluzione La pompa non si accende e Verificare il corretto collegamento della spina alla presa elettrica e Verificare che non ci siano dei fusibili guasti Allarme visibile e sonoro acceso e Verificare che il collegamenti fra connettore del tubo d aria e la pompa siano corretti e Verificare che tutti i collegamenti fra i vari tubi del materasso siano solidi e Verificare che la valvola CPR sia chiusa e Verificare che non ci siano delle crepe negli elementi del materasso Il paziente si immerge nel materasso Il livello di pressione prestabilito potrebbe essere insufficiente per sopportare il peso del paziente Aumentare il livello di pressione ed attendere per un paio di minuti Il materasso indurito con un e La funzione Autofirm rimasta attiva per un periodo di tempo troppo livello di pressione troppo alto lungo Disconnettere il connettore del tubo d aria per rilasciare l eccesso Cambiare le installazione prefissate Il materasso non stabile e Controllare che la base del materasso sia attaccata fer