Home

TLK 31 D - bei der EURO COLD CS GmbH

image

Contents

1. FENBSOSESEOE S u SUPPLY ADAPTER 12 VDC _ AC SUPPLY P A For the instruments equipped with RS485 serial communication it s indispensable that the programmed Lore For additional info please have a look at the KEY01 or A01 instruction manual parameter PACS is 5 PROGRAMMABLE PARAMETERS Here following are described all the parameters available on the instrument Some of them could be not present or because they are depending on the type of instrument or because they are automatically disabled as unnecessary Group SP parameters relative to the Set Point Par Description Range Def Note 1 nSP Number of the 1 2 1 programmable Set point 2 SPAt Active Set point 1 nSP 1 3 SP1 Set Point 1 SPLL SPHL 0 4 SP2 Set Point 2 SPLL SPHL 0 5 P2HL Upper Pr2 1999 9999 9999 measurement limit for differential control TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 10 6 P2LL Lower Pr2 1999 9999 1999 measurement limit for differential control 7 SPLL Low Set Point 1999 SPHL 1999 8 SPHL High Set Point SPLL 9999 9999 Group InP parameters relative to the measure input Par Description
2. change SP1 Value time min If it is desired an automatic cycle from the power on instead it is necessary to program the par nSP 2 to program the two Set Point values SP1 and SP2 and naturally to program the par SLor dur t and SLoF with the desired values TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 7 In this case at the end of the cycle all the ramps won t be more active A PV U nit SP 1 AUTO change Set time min Examples with starts from values lower than SP and with decreasing of SP Note In case of PID control if Auto tuning is desired whilst the ramp function is active this will not be carried out until the tuning cycle has been completed It is therefore recommended that Auto tuning be started avoiding activating the ramp function and once the tuning is finished deactivate Auto tuning Auto OFF program the desired ramp and if it automatic tuning is desired enable the Self tuning function 4 10 SOFT START FUNCTION All the parameters referring to the Soft Start functioning are contained in the group IrEG The Soft Start function only works through PID control and allows the limitation of control power when the instrument is switched on for a programmable period of time This is useful when the actuator driven by the instrument may be damaged excess power supplied when the application is not yet in the nor
3. ige Abweichungen w hrend des Abstimmzyklus weil die Variable aus Prozessgr nden steigt oder abf llt aufweist In dem Fall wird das oszillierende Autotuning empfohlen das einige ON OFF Regelungszyklen durchf hrt die bewirken dass der Prozesswert zwischen dem Wert der abgeschlossenen Set Points schwankt die zu einer Regelung vom Typ PID mit den w hrend des Autotunings ermittelten Werten berwechseln 6 Die Programmierung der Parameter verlassen 7 Den Regler an die zu steuernde Anlage anschlie en 8 Das Autotuning durch Ab und Einschalten des Ger tes starten wenn der Parameter Auto 1 oder 2 bzw durch Aktivieren des Men punktes tunE im Hauptmen oder ber die entsprechend programmierte Taste U Nun wurde die Autotuning Funktion aktiviert und dieser Zustand wird durch Blinken der Led AT ST signalisiert TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 7 Der Regler nimmt nun an der berwachten Anlage zur Berechnung der Parameter f r die PID Regelung eine Reihe von Einstellungen vor Bei Auto 1 oder Auto 2 und falls zu Beginn des Autotunings der Istwert bei Func HEAt als SP SP 2 oder gr er bei Func CooL als SP SP 2 war erscheint auf der Anzeige ErAt und das Ger t versetzt sich in den normalen Betriebsmodus nach den zuvor programmierten Parametern Um die Fehlermeldung ErAt zu l schen muss der Regler
4. AL2H 1999 alarm AL2 or Minimum set alarm AL2 for high or low alarm 40 AL2H High threshold band AL2L 9999 9999 alarm AL2 or Maximum set alarm AL2 for high or low alarm 41 HAL2 Alarm AL2 hysteresis OFF 9999 1 42 AL2d Activation delay of OFF 9999 OFF alarm AL2 sec 43 AL2i Alarm AL2 activation in no yES no case of measuring error Group AL3 parameters relative to alarm AL3 Par Description Range Def Note 44 OAL3 Output where alarm Out1 Out2 OFF AL3 is addressed Out3 Out4 OFF 45 PrA3 AL3 alarm process Pr1 Pr2 Pr1 measurement reference P1 2 P1 L 46 AL3t Alarm AL3 type LoAb HiAb LoAb see AL1t LHAb LodE HidE LHdE 47 Ab3 Alarm AL3 functioning 0 31 0 see Ab1 48 AL3 Alarm AL3 threshold AL3L AL3H 0 49 AL3L Low threshold band 1999 AL3H 1999 alarm AL3 or Minimum set alarm AL3 for high or low alarm 50 AL3H High threshold band AL3L 9999 9999 alarm AL3 or Maximum set alarm AL3 for high or low alarm 51 HAL 3 Alarm AL3 hysteresis OFF 9999 1 52 AL3d Activation delay of OFF 9999 OFF alarm AL3 sec 53 AL3i Alarm AL3 activation in no yES no case of measuring error TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 11 Group LbA parameters relative to Loop Break Alarm ASi Tacitazione Par Description Range Def Note allarmi 54 OLbA Output wher
5. Mediante il tasto U se il parametro USrb CHSP Mediante gli ingressi digitali opportunamente programmati attraverso il par diF diF CHSP SP1 2 SP1 40 HE Co Automaticamente tra SP1 e SP2 nel caso venga impostato un tempo di mantenimento dur t vedi par 4 8 Set point SP1 SP2 SP3 SP4 saranno visibili in funzione del numero massimo di Set point selezionato al parametro nSP e saranno impostabili con un valore compreso tra il valore programmato al par SPLL e il valore programmato al par SPHL Nota negli esempi che seguono il Set point viene indicato genericamente come SP comunque operativamente lo strumento agir in base al Set point selezionato come attivo 3 AVVERTENZE PER INSTALLAZIONE ED USO 3 1 USO CONSENTITO Lo strumento stato concepito come apparecchio di misura e regolazione in conformit con la norma EN61010 1 per il funzionamento ad altitudini sino a 2000 m L utilizzo dello strumento in applicazioni non espressamente previste dalla norma sopra citata deve prevedere tutte le adeguate misure di protezione Lo strumento NON pu essere utilizzato in ambienti con atmosfera pericolosa infiammabile od esplosiva senza una adeguata protezione Si ricorda che l installatore deve assicurarsi che le norme relative alla compatibilit elettromagnetica siano rispettate anche dopo l installazione dello strumento eventualmente utilizzando appositi filtri
6. Ww TLK 31 D TERMOREGOLATORE ELETTRONICO CON REGOLAZIONE DIFFERENZIALE TLK 31D 00 oo Pn Drammen dude ISTRUZIONI PER L USO Vr 01 ITA cod ISTR MTLK31DITA1 TECNOLOGIC S p A VIA INDIPENDENZA 56 27029 VIGEVANO PV ITALY TEL 39 0381 69871 FAX 39 0381 698730 internet http www tecnologic it e mail info tecnologic it Nel presente manuale sono contenute le informazioni necessarie ad una corretta installazione e le istruzioni per l utilizzo e la manutenzione del prodotto si raccomanda pertanto di leggerlo attentamente e di conservarlo La presente pubblicazione di esclusiva propriet della TECNOLOGIC S p A la quale pone il divieto assoluto di riproduzione e divulgazione anche parziale se non espressamente autorizzata La TECNOLOGIC S p A si riserva di apportare modifiche estetiche e funzionali in qualsiasi momento e senza alcun preavviso Qualora un guasto o un malfunzionamento dell apparecchio possa creare situazioni pericolose o dannose per persone co se o animali si ricorda che l impianto deve essere predisposto con dispositivi aggiuntivi atti a garantire la sicurezza La Tecnologic S p A ed i suoi legali rappresentanti non si ri tengono in alcun modo responsabili per eventuali danni a per sone cose o animali derivanti da manomissioni uso impro prio errato o comunque non conforme alle caratteristiche del lo strumento INDICE 1 DESCRIZIONE STRUMENTO 1 1 DESCRIZIONE GENERA
7. Anzeigegenauigkeit je nach F hlerausf hrung 1 0 1 Gesamtgenauigkeit 0 5 fs 1 digit Erfassungsgeschwindigkeit 130 ms Art der seriellen Schnittstelle RS 485 optoisoliert Kommunikationsprotokoll MODBUS RTU JBUS Serielle bertragungsgeschwindigkeit w hlbar zwischen 1200 38400 Baud Display 4 stellige rote Ledanzeige H he 12 mm Konformit t Vorschrift EWG EMC 2004 108 CE EN 61326 Vorschrift CEE NS 2006 95 CE EN 61010 1 7 5 TABELLE DER MESSBEREICHE EINGANG dP 0 dP 1 PTC KTY81 121 55 150 C 55 0 150 0 C SEnS Ptc 67 302 F 67 0 302 0 F NTC 103 AT2 50 110 C 50 0 110 0 C SEnS ntc 58 230 F 58 0 230 0 F TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 15
8. Den Parameter Cont Pid stellen 3 Bei Steuerung mit einfacher Wirkung ist der Parameter Func nach dem ber Ausgang 1rEG zu steuernden Prozess einzustellen 4 Einen Ausgang als 2rEG konfigurieren wenn das Ger t eine Anlage mit doppelter Wirkung steuert 5 Den Parameter Auto wie folgt einstellen 1 wenn das FAST Autotuning automatisch bei jeder Ger teeinschaltung gestartet werden soll sofern der Istwert kleiner bei Func HEAt als SP SP 2 oder gr er bei Func CooL als SP SP 2 2 wenn das FAST Autotuning automatisch bei der n chsten Ger teeinschaltung gestartet werden soll sofern der Istwert kleiner bei Func HEAt als SP SP 2 oder gr er bei Func CooL als SP SP 2 ist und nach Abschluss der Einstellung automatisch der Parameter Auto OFF gestellt wird 3 wenn das FAST Autotuning von Hand durch Aktivieren des Punktes tunE im Hauptmen bzw durch Bet tigen der entsprechend programmierten Taste U USrb tunE gestartet werden soll sofern der Istwert kleiner bei Func HEAt als SP SP 5 oder gr er bei Func CooL als SP SP 5 4 wenn es w nscht da der FAST Autotuning automatisch am nderung des Sollwert oder Ende der programmiert Zyklus von Soft Start gestartet wird Sofern der Istwert kleiner bei Func HEAt als SP SP 5 oder gr er bei Func CooL als SP SP 5 ist 1 wenn beim Einschalt
9. ISTR MTLK31DITA1 PAG 10 Quando si tenta di entrare in programmazione da tastiera mentre Gruppo InP parametri relativi all ingresso di misura in corso una comunicazione tramite la porta seriale lo strumento Par Descrizione Range Def Note visualizza buSy ad indicare lo stato di occupato 9 SEnS Tipo sonde in ingresso Pte ntc ntc fe 10 Pr2 Presenza sonda 2 yES no yES shield 11 dP Numero di cifre 0 1 0 A In decimali B ene 12 Unit Unita di misura della C F C END temperatura 13 FiL Filtro digitale ingresso OFF 20 0 1 0 RS485 fi sec Interface 14 OFS1 Offset della misura Pr1 1999 9999 0 A B law a ano a B anD 15 OFS2 Offset della misura Pr2 1999 9999 0 108 9 101819 101819 16 rot Rotazione della retta di 0 000 2 000 1 000 misura TLK31 n 1 TLK31 n 2 TLK31 n N 17 InE Condizioni per funz Our Or Ur OUr OPE in caso di errore 4 16 CONFIGURAZIONE PARAMETRI CON KEY 01 e A01 di misura Lo strumento dotato di un connettore
10. OAL1 Ausgang f r Alarm AL1 Out1 Out2 Out2 Out3 Out4 OFF 40 AL2H Oberer Alarmgrenzwert AL2 f r Bandwert Alarme oder H chster alarmgrenzwert AL2 sollwert f r tiefstwert alarm und h chstwert alarm AL2L 9999 9999 TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 12 TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 13 41 HAL2 Hysterese auf Alarm OFF 9999 1 1 Start zu jeder AL2 Z ndung 42 AL2d Einschaltverz gerung OFF 9999 OFF 2 Start zur ersten Alarm AL2 sec Z ndung 43 AL2i Alarmaktivierung AL2 no yES no 3 Start Handbuch bei Messfehler 4 Start nach SoftStart Gruppe AL3 Parameter des Alarms AL3 oder zum Wechsel Set Par Beschreibung Bereich Def Note Point i 44 0AL3 Ausgang f r Alarm AL3 Outt Out2 OFF 62 SELF Aktivierung Selftuning_ no yES no Out3 Out4 63 Pb Proportionalband 0 9999 50 OFF 64 Int Integralzeit OFF 9999 200 45 PrA3 Prozesswert f r Alarm Pr1 Pr2 Pr1 sec AL3 P1 2 P1 L 65 dEr Vorhaltezeit OFF 9999 50 46 AL3t Alarmart ALS LoAb HiAb LoAb SEC siehe AL1t LHAb LodE 66 FuOc Fuzzy overshoot control 0 00 2 00 0 5 Hi
11. Valore di scostamento OFF 9999 2 per funzionamento indice 79 Edit Modifica Set e allarmi SE AE SAE con procedura rapida SAE SAnE SE Set editabile e Al larmi non editabili AE Allarmi editabili e Set non editabile SAE Set e allarmi editabili SANE Set e allarmi non editabili 80 PASS Password di accesso ail OFF 9999 OFF parametri di funzionamento Gruppo SEr parametri relativi all a comunicazione seriale Par Descrizione Range Def Note 81 Add Indirizzo della stazione 0 255 1 per comunicazione seriale 82 baud Baud rate porta seriale 1200 2400 9600 9600 19 2 38 4 83 PACS Accesso programmaz LoCL LorE LorE tramite porta seriale LoCL No progr solo da tastiera LorE Si progr sia da seriale che da tastiera 6 PROBLEMI MANUTENZIONE E GARANZIA 6 1 SEGNALAZIONI DI ERRORE Errore Motivo Azione E1 La sonda Pr1 pu essere Verificare la corretta E1 interrotta o in connessione della cortocircuito oppure sonda con lo strumento misurare un valore al di e quindi verificare il fuori dal range consentito corretto funzionamento E2 La sonda Pr2 pu essere della sonda E2 interrotta o in cortocircuito oppure misurare un valore al di fuori dal range consentito Valore di processo non disponibile ErAt Autotuning non Premere il tasto P per eseguibile perch non far
12. connection of the probe InF Ramp not active unit min circuit or may measure a with the instrument and 74 St P_ Soft Start power 100 100 0 value outside the range check the probe works 75 SSt Soft Start time OFF OFF allowed correctly 0 1 7 59 E2 The probe Pr2 may be nF E2 interrupted or in short hrs min circuit or may measure a Group PAn parameters relative to the user interface value outside the range Par Description Range Def Note allowed 76 USrb Funzione del tasto U noF tunE noF Process measurement noF nessuna OPLO Aac not available funzione l 3 ASI CHSP ErAt Auto tuning not possible Push key P in order to tune Avvio Autotuning OFF because the process make the error o Selftuning value is too higher or too message disappear OPLO Regolazione lower Once the error has manuale open loop been found try to Aac Reset memoria repeat the auto tuning allarmi TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 12 7 3 MECHANICAL DIMENSIONS PANEL CUT OUT AND MOUNTING mm 78 noAt Auto tuning not finished Check the functioning of within 12 hours probe and actuator and try to repeat the auto tuning LbA Loop control interrupted Check the working of Loop break alarm probe and actuator and 9 swap the instrument to rEG control ErEP Possible anomaly of the Push key P EEPROM memory I
13. the condition occurs in case of under range or probe breakage Our the condition occurs in case of over range or under range or probe breakage Through the diSP parameter of the PAn unit it is possible to decide what the display is to show normally this could be the reading of probe Pr1 Pr 1 the reading of probe Pr2 Pr 2 the difference of temperature Pr1 Pr2 P1 2 the regulation voltage Pou the active Set Point SP F the operative Set Point when there are ramps activated SP o or the alarm limit AL 1 2 3 AL1 AL2 AL3 ISTR MTLK31DENG2 PAG 4 Regardless of that set on the diSP parameter it is possible to show the variables Pr1 Pr2 and Pr1 Pr2 in rotation by pressing down and releasing the U key the display will show the code that identifies the variable P2 1 Pr2 P1 2 and its measurement After 15 seconds following the last time the U key is pressed this type of display ends automatically Again in the group PAn the par AdE is present that defines the 3 led shift index functioning The lighting up of the green led indicates that the process value is within the range SP AdE SP AdE the lighting up of the led indicates that the process value is lower than SP AdE and the lighting up of the led indicates that the process value is higher than SP AdE 4 2 OUTPUTS CONFIGURATION The instrument s outputs can be programmed by entering the group of parameters Out w
14. 1 rEG 2 rEG 1 rEG N B Per gli strumenti dotati di porta di comunicazione seriale LIEGE Useita diregola ALNO AENG RS485 indispensabile che il parametro PACS sia impostato zione ALi X OFF LorE 2 rEG Uscita di regola Per maggiori informazioni e le indicazioni delle cause di errore NER x a i na ALno Uscita di allarme vedere il manuale d uso relativo al dispositivo KEY 01 normalmente aperta 5 PARAMETRI PROGRAMMABILI IO Di seguito vengono descritti tutti i parametri di cui lo strumento pu ALni Uscita di allarme essere dotato si fa presente che alcuni di essi potranno non normalmente chiusa essere presenti o perch dipendono dal tipo di strumento utilizzato con funz led negato o perch sono automaticamente disabilitati in quanto parametri non 21 O2F Funzione dell uscita 2 1 rEG 2 rEG ALno necessari vedi O1F ALno ALnc Gruppo SP parametri relativi al Set Point ALni OFF Par Descrizione Range Def Note 22 O3F Funzione dell uscita 3 1 rEG 2 rEG ALno 1 nSP Numero Set point 1 4 1 vedi O1F ALno ALnc programmabili ALni OFF 2 SPAt Set point Attivo 1 nSP 1 23 O4F Funzione dell uscita 4 1 rEG 2 rEG ALno 3 SP1 Set Point 1 SPLL SPHL 0 vedi O1F ALno ALnc 4 SP2 Set Point 2 SPLL SPHL 0 ALni OFF 5 SP3 Set Point 3 SPLL SPHL 0 Gruppo AL1 parametri relativi all allarme AL1 6 SP4 Set Point 4 SPLL SPHL 0 Par Descrizione Range Def Note 7
15. 50 wird der Einstellausgang 10 Sekunden lang aktiviert bleibt dann 10 Sekunden lang deaktiviert und so weiter solange der Messfehler besteht Im Parameter InE kann auch bestimmt werden welche Einfangsfehler dazu f hren dass das Ger t die im Parameter OPE eingestellte Leistung abgibt Folgende Eingaben sind f r den Parameter InE m glich Or Der Zustand wird vom Overrange bzw vom F hlerbruch bestimmt Ur Der Zustand wird vom Underrange bzw vom F hlerbruch bestimmt Our Der Zustand wird vom Overrange oder Underrange bzw vom F hlerbruch bestimmt Mit dem Parameter diSP in der Gruppe PAn kann f r das Display die normale Anzeige z B der Messung des F hlers Pr1 Pr 1 oder des F hlers Pr2 Pr 2 der Temperaturdifferenz Pr1 Pr2 P1 2 der Regelungsleistung Pou des aktiven Set Points SP F des Set Points f r den Betrieb wenn die Rampen aktiviert sind SP o und der Alarmschwelle AL1 2 3 AL1 AL2 AL3 ausgew hlt werden Unabh ngig von der Einstellung f r den Parameter diSP k nnen die Variablen Pri Pr2 und Pr1 Pr2 im Rotationsverfahren angezeigt werden Dazu die Taste U dr cken und loslassen Auf dem Display erscheinen jetzt abwechselnd der Code f r die Identifizierung der Variablen Pr 1 Pr 2 P1 2 und dessen Wert Dieser Anzeigemodus schaltet sich automatisch 15 Sekunden nachdem die Taste zum letzten Mal gedr ckt wurde aus Zur Gruppe PAn
16. 58 PrrG Valore di processo per Pr1 Pr2 P1 2 HidE LHdE regolazione P1 2 37 Ab2 Configurazione 0 31 0 59 HSEt Isteresi regolazione 0 9999 1 funzionamento allarme ON OFF o Soglia AL2 disinserzione Soft Start vedi i AL1t 60 CPdt Tempo ritardo OFF 9999 0 38 AL2 Soglia allarme AL2 AL2L AL2H 0 protezione sec 39 AL2L Soglia inferiore allarme 1999 AL2H 1999 compressore 2 rEG AL2 a finestra o limite 61 Auto Abilitazione dell autotu 4 3 2 1 0 inferiore del set AL2 per ning Fast 0 allarmi di minima q OFF Non abilitato 1 2 3 4 massima 1 Avvio ad ogni 40 AL2H Soglia inferiore allarme AL2L 9999 9999 accensione AL2 a finestra o limite 2 Avvio alla prima inferiore del set AL2 per accensione allarmi di minima o 3 Avvio manuale massima 4 Avvio dopo SoftStart 41 HAL2 Isteresi allarme AL2 OFF 9999 1 o al cambio Set Point 42 AL2d Ritardo attivazione al OFF 9999 OFF 62 SELF Abilitazione selftuning no yES no larme AL2 sec 63 Pb Banda proporzionale 0 9999 50 43 AL2i Attivazione allarme AL2 no yES no 64 Int Tempo integrale OFF 9999 200 in caso di errore di sec m sura 65 dEr Tempo derivativo OFF 9999 50 Gruppo AL3 parametri relativi all allarme AL3 sec Par Descrizione Range Def Note 66 FuOc Fuzzy overshoot control 0 00 2 00 0 5 44 OAL3 Uscita destinata all al Out1 Out2 OFF 67 teri Tempo di ciclo uscita 0 1 130 0 20 0 larme AL3 Out3
17. Ab1 0 NORMAL BEHAVIOUR The alarm is always activated when there are alarm conditions 1 ALARM NOT ACTIVATED AT SWITCH ON If when switched on the instrument is in alarm condition the alarm is not activated It will be activated only when the process value is in non alarm conditions and then back in alarm conditions PV AL1 exemple with absolute low alarm ALARM DELAY the alarm output may behave in two different ways depending on the value added to par Ab1 0 ALARM NOT DELAYED The alarm is immediately activated when the alarm condition occurs 2 ALARM DELAYED When the alarm condition occurs delay counting begins as programmed on par AL1d expressed in sec and the alarm will be activated only after the elapsing of that time ALARM LATCH the alarm output may behave in two different ways depending on the value added to par Ab1 0 ALARM NOT LATCHED The alarm remains active in alarm conditions only 4 ALARM LATCHED The alarm is active in alarm conditions and remains active even when these conditions no longer exist until the correctly programmed key U USrb Aac has been pushed PV AL1 gt tim e 0 Ab1 4 exemple with absolute high alarm ALARM AKNOWLEDGEMENT the alarm output may behave in two different ways depending on the value added to par Ab1 0 ALARM NOT AKNOWLEDGED The alarm always remains active in
18. Alarm wird aktiviert wenn der Istwert den im Parameter AL1 eingegebenen Alarmgrenzwert unterschreitet Es ist zu den Abs AL1L und AL1H zu gliedern mit dieser Beschaffenheit m glich tiefster alarmgrenzwert sollwert und h chster alarmgrenzwert sollwert HiAb ABSOLUTER H CHSTWERTALARM Der Alarm wird aktiviert wenn der Istwert ber den im Parameter AL1 eingegebenen Alarmgrenzwert berschreitet Es ist zu den Abs AL1L und AL1H zu gliedern mit dieser Beschaffenheit m glich tiefster alarmgrenzwert sollwert und h chster alarmgrenzwert sollwert off LodE RELATIVER TIEFSTWERTALARM Der Alarm wird aktiviert wenn der Istwert den Wert SP AL1 unterschreitet Es ist zu den Abs AL1L und AL1H zu gliedern mit dieser Beschaffenheit m glich tiefster alarmgrenzwert sollwert und h chster alarmgrenzwert sollwert HidE RELATIVER H CHSTWERTALARM Der Alarm wird aktiviert wenn der Istwert den Wert SP AL1 berschreitet Es ist zu den Abs AL1L und AL1H zu gliedern mit dieser Beschaffenheit m glich tiefster alarmgrenzwert sollwert und h chster alarmgrenzwert sollwert HidE LHAb ABSOLUTER BANDWERT ALARM Der Alarm wird aktiviert wenn der Istwert den im Parameter AL1L eingegebenen Grenzwert unterschreitet oder den im Parameter AL1H eingegebenen Grenzwert berschreitet LHdE RELATIVER BANDWERT ALARM Der Alarm wird aktiviert wenn der Istwert den Wert SP AL1L unterschreitet oder wenn er den We
19. Anstieg der Differenz Pr1 Pr2 widersetzt Umgekehrt wird die Betriebsart Func HEAt f r die Anwendungen eingesetzt bei denen sich die Differenz Pr1 Pr2 durch die Wirkung des Stellantriebs erh ht und sich folglich dem nat rlichen Abfall der Differenz Pr1 Pr2 widersetzt Nat rlich haben die Betriebsart Neutraler Bereich oder die doppelte Wirkung beide eine kontrastierende Wirkung Temp SP1 HSEt Beispiel f r die Differenzregelung ON OFF On FA mit Func CooL Achtung Der Regler wurde schon werkseitig f r die Differenzregelung und die Anzeige der Temperaturdifferenz Pr1 Pr2 programmiert TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 5 4 4 EIN AUS REGELUNG 1 rEG Alle Parameter der EIN AUS REGELUNG befinden sich in der Gruppe IrEG Diese Regelart kann durch Einstellen des Parameters Cont On FS oder On FA aktiviert werden und wirkt auf den als 1 rEG konfigurierten Ausgang nach der programmierten Messung dem aktiven Sollwert SP der Betriebsart Func und der Hysterese HSEt Das Ger t nimmt bei Cont On FS eine EIN AUS REGELUNG mit symmetrischer Hysterese vor bzw bei Cont On Fa eine EIN AUS REGELUNG mit asymmetrischer Hysterese Der Regler verh lt sich dabei wie folgt bei umgekehrtem Wirkungssinn oder Heizen FunC HEAt deaktiviert er den Ausgang wenn der Istwert den Wert SP HSEt bei symmetrischer Hyst
20. BT 2006 95 CE EN 61010 1 min 12 mm N 7 5 TABELLA RANGE DI MISURA INPUT dP 0 dP 1 PTC KTY81 121 55 150 C 55 0 150 0 SEnS Ptc 67 302 F 67 0 302 0 F NTC 103 AT2 50 110C 50 0 110 0 C SEnS ntc 58 230 F 58 0 230 0 F 7 6 CODIFICA DELLO STRUMENTO TLK31abcdefghhD a INGRESSO T termistori PTC NTC b USCITA OUT1 R Arel O Uscita in tensione per SSR c USCITA OUT2 R Arel O Uscita in tensione per SSR Non presente d USCITA OUT3 R Arel O Uscita in tensione per SSR Non presente e USCITA OUT4 R Arel O Uscita in tensione per SSR Non presente f INTERFACCIA DI COMUNICAZIONE S Interfaccia Seriale RS 485 Nessuna Interfaccia g INGRESSI DIGITALI I Presenti Non presenti hh CODICI SPECIALI TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 14 Ww TLK 31 D ELECTRONIC THERMOCONTROLLER WITH DIFFERENTIAL CONTROL MODE Tl ey OPERATING INSTRUCTIONS Vr 02 ENG cod ISTR MTLK31DENG2 TECNOLOGIC S p A VIA INDIPENDENZA 56 27029 VIGEVANO PV ITALY TEL 39 0381 69871 FAX 39 0381 698730 internet http www tecnologic it e mail info tecnologic it FOREWORD This manual contains the information necessary for the product to be installed correctly and also
21. C Temperatur 13 FiL Digitaler Eingangsfilter OFF 20 0 1 0 sec 14 OFS1 Offset der Messung Pr1 1999 9999 0 15 OFS2 Offset der Messung Pr2 1999 9999 0 16 rot Rotation der 0 000 2 000 1 000 Messgeraden 17 InE Betriebszustand fir Our 0Or Ur OUr OPE bei Messfehler Our Overrange und Underrange Or nur Overrange Ur nur Underrange 18 OPE Ausgangsleistung bei 100 100 0 Messfehler 19 dIF Funktion noF AaC noF Digitaleingang ASi Hold noF keine Funktion OFF CHSP Aac Reset SP1 2 gespeicherter Alarm HE Co ASi Alarm quittiert HoLd Erfassung des Messwertes OFF Zustand OFF CHSP Auswahl Sequenz aktiv Sollwerte SP1 2 Sollwerte SP1 oder SP2 HE Co Auswahl HEAt mit SP1 oder CooL mit SP2 Gruppe Out Parameter der Ausg nge Par Beschreibung Bereich Def Note 20 O1F Funktion Ausgang 1 1 rEG 2 rEG 1 rEG 1 rEG Hauptregelausg ALno ALnc ang Alni OFF 2 rEG Nebenregelausg ang ALno Alarm norm auf ALnc Alarm norm zu ALni Alarm norm zu mit Hinweis vom Vorder led des Ger tes leugnet 21 O2F Funktion Ausgang 2 1 rEG 2 rEG ALno siehe O1F ALno ALnc ALni OFF 22 O3F Funktion Ausgang 3 1 rEG 2 rEG ALno siehe O1F ALno ALnc ALni OFF 23 O4F Funktion Ausgang 4 1 rEG 2 rEG ALno siehe O1F ALno ALnc ALni OFF Gruppe AL1 Parameter des Alarms AL1 Par Beschreibung Bereich Def Note 24
22. O1F 02F 03F 04F programmando il parametro relativo all uscita desiderata ALno se l uscita di allarme deve essere attivata quando l allarme attivo mentre disattivata quando l allarme non attivo Alnc se l uscita di allarme deve essere attivata quando l allarme non attivo mentre disattivata quando l allarme attivo ALni se si desidera lo stesso funzionamento di ALnc ma con fun zionamento del led frontale negato in questo caso il led frontale dello strumento segnala lo stato dell uscita Quindi accedere al gruppo ILbA e programmare al parametro OLbA su quale uscita dovr essere destinato il segnale di allarme L allarme di Loop Break viene attivato se la potenza di uscita rima ne al valore del 100 per il tempo impostato al par LbAt espresso in sec Per non dar luogo a falsi allarmi il valore di impostazione di questo parametro va eseguita tenendo conto del tempo di raggiungimento del valore di Set quando il valore misurato lontano da questo ad esempio all accensione dell impianto All intervento dell allarme lo strumento visualizza il messaggio LbA e si comporta come nel caso di un errore di misura fornen do in uscita la potenza impostata al par OPE programmabile nel gruppo InP Per ripristinare il normale funzionamento dopo l allarme selezionare il modo di regolazione OFF e quindi reimpostare il funzionamento di regolazion
23. Out4 1rEg sec OFF TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 12 68 Prat Rapporto potenza 0 01 99 99 1 00 2 rEg 1 rEg 69 ter2 Tempo di ciclo uscita 0 1 130 0 10 0 2 rEg sec 70 rS Reset manuale 100 0 100 0 0 0 71 SLor Velocit della prima 0 00 99 99 InF rampa InF InF Rampa non attiva unit min 72 dur t Tempo di mantenimen 0 00 99 59 InF to tra le due rampe InF InF Tempo non attivo hrs min 73 SLoF Velocit della seconda 0 00 99 99 InF rampa InF InF Rampa non attiva unit min 74 St P Potenza Soft Start 100 100 0 75 SSt Tempo Soft Start OFF OFF 0 1 7 59 InF hrs min Gruppo PAn parametri relativi all interfaccia operatore Par Descrizione Range Def Note 76 USrb Funzione del tasto U noF tunE noF noF nessuna OPLO Aac funzione ASI CHSP tune Avvio Autotuning OFF o Selftuning OPLO Regolazione manuale open loop Aac Reset memoria allarmi ASi Tacitazione allarmi CHSP Cambio Set att OFF messa in OFF della regolazione 77 diSP Variabile visualizzata Pr1 Pr2 P1 2 sul display P1 2 Pou Pr1 Valore misura Pri SP F SP o Pr2 Valore misura Pr2 AL1 AL2 P1 2 Valore misura AL3 Pri Pr2 Pou Potenza di regolazione SP F Set attivo SP o Set operativo AL1 Soglia AL1 AL2 Soglia AL2 AL3 Soglia AL3 78 AdE
24. SPLL Set Point minimo 1999 SPHL 1999 24 OAL1 Uscita destinata all al Outi Out2 Out2 8 SPHL Set Point massimo SPLL 9999 9999 lame ALS u TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 11 25 PrA1 Valore di processo per Pr1 Pr2 Pri 45 PrA3 Valore di processo per Pr1 Pr2 Pri allarme AL1 P1 2 allarme AL3 P1 2 26 AL1t Tipo allarme AL1 LoAb HiAb LoAb 46 ALSt Tipo allarme ALS LoAb HiAb LoAb LoAb minima assoluto LHAb LodE vedi AL1t LHAb LodE HiAb massima HidE LHdE HidE LHdE assoluto 47 Ab3 Configurazione 0 31 0 LHAb a finestra funzionamento allarme assoluti ALS LodE minima relativo vedi AL1t HidE massima relativo 48 AL3 Soglia allarme AL3 AL3L AL3H 0 LHdE a finestra relativi 49 AL3L Soglia inferiore allarme 1999 AL3H 1999 27 Ab1 Configurazione 0 31 0 AL3 a finestra o limite funzionamento AL1 inferiore del set AL3 per 1 non attivo allarmi di minima o all avviamento massima 2 ritardato 50 AL3H Soglia inferiore allarme AL3L 9999 9999 4 memorizzato AL3 a finestra o limite 8 tacitabile inferiore del set AL3 per 16 non attivo al allarmi di minima a cambio Set All relati
25. THE EVENT OF MEASUREMENT ERROR PrA1 ALARM PROCESS MEASUREMENT Through this parameter it is possible to set the process variable used by the alarm for operating In fact the alarm can operate considering the process variable as the value measured at input 1 Pr1 the value measured at input 2 Pr2 the difference between the two inputs Pr1 Pr2 P1 2 or can consider the difference between the two inputs Pr1 Pr2 but with a maximum limit and a minimum limit for the Pr2 measurement Pr2 P1 L AL1t ALARM TYPE different ways LoAb ABSOLUTE LOW ALARM The alarm is activated when the process value goes below the alarm threshold set on parameter AL1 and will be deactivated when it goes above the value AL1 HAL1 With this mode is possible to program the minimum and the maximum set of AL1 by AL1L and AL1H parameters HiAb ABSOLUTE HIGH ALARM The alarm is activated when the process value goes higher than the alarm threshold set on parameter AL1 and will be deactivated when it goes below the value AL1 HAL 1 With this mode is possible to program the minimum and the maximum set of AL1 by AL1L and AL1H parameters the alarm output can behave in six time OUT ALI j off Za LodE DEVIATION LOW ALARM The alarm is activated when the process value goes below the value SP AL1 and will be deactivated when it goes above the value SP AL1 HAL 1 With this
26. che permette il 48 OPE Potenza in uscita in ca 100 100 0 trasferimento da e verso lo strumento dei parametri di so di errore di misura funzionamento attraverso i dispositivi TECNOLOGIC KEY01 o 19 diF Funzione ingressi noF AaC noF TECNOLOGIC A01con connettore a 5 poli digitali ASi Hold Questi dispositivi sono utilizzabili per la programmazione in serie noF nessuna OFF CHSP di strumenti che devono avere la stessa configurazione dei funzione SP1 2 SP1 4 parametri o per conservare una copia della programmazione di uno Aac Reset memoria HE Co strumento e poterla ritrasferire rapidamente allarmi mediante DIG Per l utilizzo dei dispositivi KEY 01 o A01 possibile alimentare IN1 solo il dispositivo o solo lo strumento ASi Tacitazione allar Strumento alimentato e dispositivo non alimentato mi mediante DIG IN1 SUPPLY HoLd Blocco misura ren mediante DIG IN1 DODODDDOS OFF messa in OFF gt i della regolazione me S diante DIG IN 1 of i CHSP Selezione Set p point a rotazione me f i diante DIG IN1 SP1 2 Selezione Set si SP1 e SP2 median Strumento alimentato dal dispositivo te DIG IN 1 pet SP1 4 Selezione Set IITITITTTE mediante DIG IN 1 e 2 i HE Co Selezione S i HEAt con SP1 o CooL iti E i con SP2 mediante b q DIG IN 1 SUPPLY ADAPTER Gruppo Out parametri relativi alle uscite A Par Descrizione Range Def Note 12 VDC AC SUPPLY 20 O1F Funzione dell uscita 1
27. contained in the group PAn The parameter can be programmed as noF no function tunE Pushing the key for 1 sec at least it is possible to activate deactivate Auto tuning or Self tuning OPLO Pushing the key for 1 sec at least it is possible to swap from automatic control rEG to manual one OPLO and vice versa Aac Pushing the key for 1 sec at least it is possible to acknowledge the alarm see par 4 10 ASi Pushing the key for 1 sec at least it is possible to acknowledge an active alarm see par 4 10 TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 9 CHSP Pushing the key for 1 sec at least it is possible to select one of the 4 pre programmed Set Points on rotation OFF Pushing the key for 1 sec at least it is possible to swap from automatic control rEG to OFF control OFF and vice versa 4 14 DIGITAL INPUT The instrument can be equipped with an digital input The function of the digital input can be set through par diF contained in the group InP The parameter can be programmed as noF no function Aac Closing the contact connected to the digital input 1 it is possible to acknowledge the alarm see par 4 11 ASi Closing the contact connected to the digital input 1 it is possible to acknowledge an active alarm see par 4 11 Hold Closing the contact connected to the digital input 1 there is the hold o
28. di temperatura Pr1 Pr2 4 4 REGOLATORE ON OFF 1 rEG Tutti i parametri riguardanti la regolazione ON OFF sono contenuti nel gruppo IrEG Questo modo di regolazione attuabile impostando il parametro Cont On FS o On FA ed agisce sull uscita configurata come 1 rEG in funzione del valore di processo stabilito dal par PrrG del Set point SP attivo del modo di funzionamento Func e dell isteresi HSEt programmati Lo strumento attua una regolazione ON OFF con isteresi simmetrica se Cont On FS oppure con isteresi asimmetrica se Cont On Fa Il regolatore si comporta nel seguente modo in caso di azione inversa o di riscaldamento FunC HEAt disattiva l uscita quando il valore di processo raggiunge il valore SP HSEt nel caso di isteresi simmetrica oppure SP nel caso di isteresi asimmetrica per riattivarla quando scende sotto al valore SP HSEt Viceversa in caso di azione diretta o di raffredamento Func CooL disattiva l uscita quando il valore di processo raggiunge il valore SP HSEt nel caso di isteresi simmetrica oppure SP in caso di isteresi asimmetrica per riattivarla quando sale al di sopra del valore SP HSEt OUT 1 rEG HEAt On FS CooL On FS 4 5 REGOLAZIONE ON OFF A ZONA NEUTRA 1 rEG 2 rEG Tutti i parametri riguardanti la regolazione ON OFF a Zona Neutra sono contenuti nel gruppo IrEG Questo funziona
29. e o 2 possibile impostare un offset positivo o negativo che viene semplicemente sommato al valore letto dalla sonda prima della visualizzazione e che risulta costante per tutte le misure Se invece si desidera che l offset impostato non sia costante per tutte le misure possibile effettuare la calibrazione su due punti a piacere In questo caso per stabilire i valori da impostare ai parametri OFSt e rot occorrer applicare le seguenti formule rot D2 D1 M2 M1 OFS D2 rot x M2 dove M1 valore misurato 1 D1 valore da visualizzare quando lo strumento misura M1 M2 valore misurato 2 D2 valore da visualizzare quando lo strumento misura M2 Ne deriva che lo strumento visualizzer DV MV x rot OFS dove DV Valore visualizzato MV Valore misurato Esempio Si desidera che lo strumento visualizzi il valore realmente misurato a 20 ma che a 100 visualizzi un valore inferiore di 10 90 Ne deriva che M1 20 D1 20 M2 100 D2 90 rot 90 20 100 20 0 875 OFS 90 0 875 x 100 2 5 Mediante il par FiL possibile impostare la costante di tempo del filtro software relativo alla misura del valore in ingresso in modo TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 4 da poter diminuire la sensibilit ai disturbi di misura aumentando il tempo In caso di errore di misura lo strumento provvede a
30. fornire in uscita la potenza impostata al par OPE Questa potenza sar calcolata in base al tempo di ciclo programmato per il regolatore PID mentre per i regolatori ON OFF viene automaticamente considerato un tempo di ciclo di 20 sec es in caso di errore sonda con regolazione ON OFF e OPE 50 l uscita di regolazione si attiver per 10 sec quindi rester disattivata per 10 sec e cos via sino al permanere dell errore di misura Mediante il par InE possibile anche stabilire quali sono le condizioni di errore dell ingresso che portano lo strumento a fornire in uscita la potenza impostata al par OPE Le possibilit del par InE sono Or la condizione determinata dall overrange o dalla rottura del la sonda Ur la condizione determinata dall underrange o dalla rottura della sonda Our la condizione determinata dall overrange o dall underran ge o dalla rottura della sonda Attraverso il par diSP presente nel gruppo IPAn possibile stabilire la normale visualizzazione del display che pu essere la misura della sonda Pr1 Pr 1 la misura della sonda Pr2 Pr 2 la differenza di temperatura Pr1 Pr2 P1 2 la potenza di regolazione Pou il Set Point attivo SP F il Set Point operativo quando vi sono delle rampe attive SP o o la soglia di allarme AL1 2 3 AL1 AL2 AL3 Indipendentemente da quanto impostato al par diSP possibile visualizzare
31. geh rt auch der Parameter AdE dieser legt den Betrieb des 3 stelligen Led Abweichungsindex fest Durch Aufleuchten der gr nen Led wird signalisiert dass der Istwert im Bereich SP AdE SP AdE liegt das Aufleuchten der Led bedeutet dass der Istwert niedriger ist als der Wert SP AdE und das Aufleuchten der Led hei t dass der Istwert h her als der Wert SP AdE ist 4 2 KONFIGURATION DER AUSG NGE Die Ausg nge des Ger tes k nnen in der Parametergruppe Out konfiguriert werden und zwar je nach der Anzahl der im Ger t verf gbaren Ausg nge bestehen die folgenden Parameter O1F O2F s O3F O4F Die Ausg nge konfigurieren Hauptregelausgang 1 rEG Nebenregelausgang 2 rEG Alarmausgang normalerweise auf ALno Alarmausgang normalerweise zu ALnc Alarmausgang normalerweise zu aber mit Hinweis vom Vorder led des Ger tes leugnet ALni Ausgang deaktiviert OFF Die Kombination Ausgangsnummer Alarmnummer wird hingegen in der entsprechenden Alarmgruppe vorgenommen IAL1 AL2 oder IAL3 lassen sich f r die folgenden Betriebsarten 4 3 W RMEREGLER MIT ABSOLUTER TEMPERATUR ODER TEMPERATURDIFFERENZ Mithilfe des Parameters PrrG kann die Prozessvariable die der W rmeregler w hrend des Betriebs verwenden soll eingestellt werden Der W rmeregler kann als Prozessvariable den Wert der am Eingang 1 Pr1 oder am Eingang 2 Pr
32. in case of The led relative to 2 rEG output blinks during the phases of output fast processes the cycle times tcr1 and tcr2 have to have a low activation delay caused by Compressor Protection function value with a very frequent intervention of the control outputs In this case use of solid state relays SSR to drive the actuators is 4 6 SINGLE ACTION PID CONTROL 1 rEG recommended All the parameters referring to PID control are contained in the The Double Action PID control algorithm needs the programming of group IrEG the following parameters The Single Action PID control can be obtained by programming Pb Proportional Band par Cont Pid and works on the output 1rEG depending on the ter1 Cycle time of the output 1 rEG active Set Point SP on the functioning mode Func and on the ter 2 Cycle time of the output 2 rEG instrument s PID algorithm with two degree of freedom Int Integral Time In order to obtain good stability of the process variable in the event rS Manual Reset if Int 0 only of fast processes the cycle time tcr1 has to have a low value with dEr Derivative Time a very frequent intervention of the control output FuOC Fuzzy Overshoot Control In this case use of a solid state relay SSR is recommended for Prat Power Ratio or relation between power of the element driving the actuator controlled by output 2 rEG and power of the ele
33. is held down the user returns to the previous programming level until he exits the programming mode Outside the programming mode it permits visualisation of the output control power 4 U key This is used to display the temperatures read by the probes Pr1 and Pr2 and their difference Pr1 Pr2 It can also be programmed through the USrb parameter for Activating Autotuning or selftuning setting the instrument to manual regulation setting the alarm changing the active Set Point and deactivating the regulation 5 Led OUT1 indicates the state of output OUT1 6 Led OUT 2 indicates the state of output OUT2 7 Led OUT3 indicates the state of output OUT3 8 Led OUTA indicates the state of output OUT4 9 Led SET when flashing it indicates access to the programming mode 10 Led AT ST indicates that the Self tuning function is activated light on or that Auto tuning flashing is in progress 11 Led Shift index indicates that the process value is lower than the one programmed on par AdE 12 Led Shift index indicates that the process value is within the range SP AdE SP AdE 13 Led Shift index indicates that the process value is higher than the one set on par AdE 2 PROGRAMMING 2 1 FAST PROGRAMMING OF THE SET POINT This procedure permits rapid programming of the active Set Point and possibly the alarm thresholds see par 2 3 Push key P then release it and
34. la configurazione di funzionamento degli allarmi il cui interven to legato al valore di processo AL1 AL2 AL3 necessario pri ma stabilire a quale uscita deve corrispondere l allarme Per fare questo occorre configurare innanzitutto nel gruppo di para metri Out i parametri relativi alle uscite che si desiderano utiliz zare come allarmi O1F O2F 03F 04F programmando il parametro relativo all uscita desiderata ALno se l uscita di allarme deve essere attivata quando l allarme attivo mentre disattivata quando l allarme non attivo Alnc se l uscita di allarme deve essere attivata quando l allarme non attivo mentre disattivata quando l allarme attivo in que sto caso il led frontale dello strumento segnala lo stato dell allarme ALni se si desidera lo stesso funzionamento di ALnc ma con fun zionamento del led frontale negato in questo caso il led frontale dello strumento segnala lo stato dell uscita Nota In tutti gli esempi che seguono viene fatto riferimento allal larme AL1 Naturalmente il funzionamento degli altri allarmi risulta analogo Accedere quindi al gruppo IAL1 e programmare al parametro OAL1 su quale uscita dovr essere destinato il segnale di allarme Il funzionamento dell allarme AL1 invece stabilito dai parametri PrA1 VALORE DI PROCESSO PER L ALLARME AL1t TIPO DI ALLARME Ab1 CONFIGURAZIONE DELL ALLARME AL
35. le variabili Pr1 Pr2 e Pri Pr2 a rotazione premendo e rilasciando il tasto U il display mostrer alternativamente il codice che identifica la variabile Pr 1 Pr 2 P1 2 e il suo valore L uscita da questa modalit di visualizzazione avviene automatica mente dopo 15 secondi circa dall ultima pressione del tasto U Sempre nel gruppo PAn presente il par AdE che stabilisce Il funzionamento dell indice di scostamento a 3 led L accensione del led verde Indica che il valore di processo al l interno del campo SP AdE SP AdE l accensione del led che il valore di processo inferiore al valore SP AdE e l accensione del led che il valore di processo superiore al valore SP AdE 4 2 CONFIGURAZIONE DELLE USCITE Le uscite dello strumento possono essere configurate nel gruppo di parametri Out dove si trovano in funzione del numero di uscite disponibili sullo strumento i relativi parametri O1F O2F O3F 04F Le uscite possono essere configurate per i seguenti funzionamenti Uscita di regolazione primaria 1 rEG Uscita di regolazione secondaria 2 rEG Uscita di allarme normalmente aperta ALno Uscita di allarme normalmente chiusa ALnc Uscita di allarme normalmente chiusa ma con indicazione del led frontale dello strumento negata ALni Uscita disabilitata OFF L abbinamento numero uscita numero allarme viene invece effettuata nel gruppo relativo all
36. mit Dichtung Umweltbelastung 2 Betriebstemperatur 0 50 C Feuchte im Betriebsbereich 30 95 relative Luftfeuchte nicht kondensierend Transport und Lagertemperatur 10 60 C TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 14 7 3 MECHANISCHE MERKMALE AUSSPARUNG UND 7 6 CODIERUNG DES GER TES BEFESTIGUNG mm TLK31abcdefghhD a EINGANG T Thermistoren PTC NTC b AUSGANG OUT1 R Relaisausgang O Spannungsausgang VDC f r SSR c AUSGANG OUT2 R Relaisausgang O Spannungsausgang VDC f r SSR Nicht vorhanden d AUSGANG OUT3 R Relaisausgang O Spannungsausgang VDC f r SSR Nicht vorhanden R Relaisausgang O Spannungsausgang VDC f r SSR Nicht vorhanden min 12 mm BRACKETS f KOMMUNIKATIONSSCHNITTSTELLE S Serielle Schnittstelle RS 485 Fe Keine Schnittstelle 34 g DIGITALEINGANGE I Mit Digitaleingange Keine Digitaleingange hh SONDERCODIERUNGEN DOO vs TOO PANEL GASKET MAX 12 mm N 7 4 FUNKTIONSMERKMALE Regelung EIN AUS EIN AUS bei Neutraler Zone PID mit einfacher Wirkung PID mit doppelter Wirkung Messbereich je nach F hlerausf hrung siehe Tabelle
37. the display will visualise SP n where n is the number of the Set Point active at that moment alternatively to the programmed value To modify the value press UP key to increase it or the DOWN key to decrease it These keys change the value one digit at a time but if they are pressed for more than one second the value increases or decreases rapidly and after two seconds in the same condition the changing speed increases in order to allow the desired value to be reached rapidly Once the desired value has been reached by pushing key P it is possible to exit by the fast programming mode or it is possible to visualise the alarm thresholds see par 2 3 To exit the fast Set programming it is necessary to push key P after the visualisation of the last Set Point or alternatively if no key is pressed for approx 15 seconds the display will return to normal functioning automatically 2 2 SELECTION OF THE CONTROL STATE AND PARAMETER PROGRAMMING By pushing key P and holding it down for approx 2 sec it is possible to enter into the main selection menu Using the UP or DOWN keys it is then possible to roll over the selections OPEr to enter into the operating parameters menu ConF to enter into the configuration parameters menu OFF to swap the regulator into the OFF state rEG to swap the regulator into the automatic control state tunE to activate the Auto tuning or Self
38. the regulator acts on the regulation outputs so it keeps the difference Pr1 Pr2 equal to the Set Point value The difference between the two modes lies in the fact that the P1 L mode activates a limit in the regulator in terms of the calculation of the temperature difference according to the P2HL and P2LL parameters both contained in the ISP so that If Pr2 is gt P2HL the process value considered by the regulator is Pr1 P2HL If Pr2 is lt P2LL the process value considered by the regulator is Pr1 P2LL On exceeding the limits set P2HL and P2LL by the Pr2 tempera ture regulation takes place as if the Pr2 temperature is the value of the limit regardless of the value actually read The aim of this function is to limit the differential regulation within a maximum range of the Pr2 measurement With the differential regulation the working mode Func CooL is used for applications with which the action of the actuator reduces the Pr1 Pr2 difference thus countering the Pr1 Pr2 difference that naturally tends to increase Viceversa the Func HEAt mode is used for applications with which the action of the actuator increases the Pr1 Pr2 difference thus countering the Pr1 Pr2 difference that naturally tends to decrease Obviously the Neutral Zone mode or the double action mode will set off both actions to 4 4 ON OFF CONTROL 1 rEG All the parameters referring to the ON OFF c
39. to al par Ab1 0 COMPORTAMENTO NORMALE L allarme viene attivato sempre quando vi sono le condizioni di allarme 16 ALLARME NON ATTIVO AL CAMBIO DEL SET POINT Se dopo il cambio del Set Point lo strumento si trova nelle condizioni di allarme questo non viene attivato L allarme si attiver solo quan do il valore di processo dopo il cambio del Set non si portato nelle condizioni di non allarme e successivamente nelle condizioni di allarme AL1i ATTIVAZIONE ALLARME IN CASO DI ERRORE DI MI SURA consente di stabilire in che condizione si deve porre l allar me quando lo strumento ha un errore di misura yES allarme attivo no allarme disattivato 4 12 FUNZIONE ALLARME DI LOOP BREAK Tutti i parametri riguardanti le funzioni relativi all allarme di Loop Break sono contenuti nel gruppo ILbA Su tutti gli strumenti disponibile l allarme di Loop Break che inter viene quando per un motivo qualsiasi cortocircuito di una TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 9 termocoppia inversione di una termocoppia interruzione del carico si interrompe l anello di regolazione Per la configurazione dell uscita a cui destinare l allarme di Loop Break necessario prima stabilire a quale uscita deve corrisponde re l allarme Per fare questo occorre configurare nel gruppo di parametri Out il parametro relativo all uscita che si desidera utilizzare
40. used to control plants where there compressor short cycles is an element which causes a positive increase ex Heating and This function allows a control by time on the output 2 rEG an element which causes a negative increase ex Cooling activation independently by the temperature control request This type of control can be obtained when 2 outputs are The protection is a delayed after deactivation type programmed respectively as 1 rEG and 2 rEG and the par Cont This protection permits to avoid the output activation for a time Pid programmable on par CPdt expressed in sec the output The element causing a positive increase has to be connected to activation will occurs only after the elapsing of time CPdt the output programmed as 1rEG while the element causing a The time programmed on parameter CPdt is counted starting Negative increase has to be connected to the output programmed from the last output deactivation as 2 rEG Obviously whether during the time delay caused by the The Double Action PID control works on the outputs 1 rEG and compressor protection function the regulator request should stop 2 rEG depending on the active Set Point SP and on the the output activation foreseen after time CPdt would be erased instrument s PID algorithm with two degrees of freedom The function is not active programming CPdt OFF In order to obtain good stability of the process variable
41. 1 SOGLIA DI ALLARME AL1L SOGLIA INFERIORE ALLARME per allarme a finestra O LIMITE INFERIORE DEL SET DI ALLARME AL1 per allarmi di minima o di massima AL1H SOGLIA SUPERIORE ALLARME per allarme a finestra O LIMITE SUPERIORE DEL SET DI ALLARME AL1 per allarmi di minima o di massima HAL1 ISTERESI DEGLI ALLARMI AL1d RITARDO ATTIVAZIONE DELL ALLARME in sec AL1i COMPORTAMENTO ALLARME IN CASO DI ERRORE DI MISURA PrA1 VALORE DI PROCESSO ALLARME Attraverso il para metro possibile stabilire la variabile di processo utilizzata dall al larme per operare L allarme pu infatti operare considerando come variabile di pro cesso il valore misurato dall ingresso 1 Pr1 il valore misurato dal l ingresso 2 Pr2 oppure pu considerare la differenza tra i 2 ingressi Pr1 Pr2 AL1t TIPO DI ALLARME Si possono avere 6 differenti com portamenti dell uscita di allarme LoAb ALLARME ASSOLUTO DI MINIMA L allarme viene attivato quando il valore di processo scende al di sotto della soglia di allar me impostata al parametro AL1 per disattivarsi quando sale al di sopra della soglia AL1 HAL 1 Con questa modalit possibile impostare ai par AL1L e AL1H i limiti entro i quali possibile programmare la soglia AL1 HiAb ALLARME ASSOLUTO DI MASSIMA L allarme viene atti vato quando il valore di processo sale al di sopra della soglia di al larme impos
42. 1L 9999 9999 31 HAL1 Hysterese auf Alarm AL1 OFF 9999 32 AL1d Einschaltverz gerung Alarm AL1 OFF 9999 sec OFF 33 AL1i Alarmaktivierung AL1 bei Messfehler no yES no Gru ppe 1 AL2 Parameter des Alarms AL2 Par Beschreibung Bereich Def Note 34 OAL2 Ausgang f r Alarm AL2 Out1 Out2 Out3 Out4 OFF OFF 35 PrA2 Prozesswert f r Alarm AL2 Pr1 Pr2 P1 2 P1 L Pr1 36 AL2t Alarmart AL1 siehe AL1t LoAb HiAb LHAb LodE HidE LHdE LoAb 37 Ab2 Betriebskonfiguration Alarm AL2 siehe Ab1 0 31 38 AL2 Alarmgrenzwert AL2 AL2L AL2H 39 AL2L Unterer Alarmgrenzwert AL2 f r Bandwert Alarme oder Tiefster alarmgrenzwert AL2 sollwert f r tiefstwert alarm und h chstwert alarm 1999 AL2H 1999 5 P2HL Obere Grenze Wert Pr2 1999 9999 9999 f r die Differenzregelung 6 P2LL Untere Grenze Wert 1999 9999 1999 Pr2 fur die Differenzregelung 7 SPLL Tiefster Sollwert 1999 SPHL 1999 8 SPHL H chster Sollwert SPLL 9999 9999 Gruppe InP Parameter des Messeingangs Par Beschreibung Bereich Def Note 9 SEnS F hlerart am Eingang Ptc ntc ntc 10 Pr2 F hler vorhanden Pr2 yES no yES 11 dP Dezimalzahlen 0 1 0 12 Unit Mafeinheit der C F
43. 2 gemessen wurde oder die Temperaturdifferenz zwischen beiden Eing ngen Pr1 Pr2 P1 2 verwenden oder er geht von der Differenz der beiden Eing nge Pr1 Pr2 aus und legt einen H chstwert und einen Mindestwert f r die Messung Pr2 P1 L zugrunde Mit den Einstellungen PrrG P1 2 oder P1 L arbeitet der Warmeregler wie ein Differenzregler In diesen F llen wirkt der Regler auf die Regelausg nge so dass die Differenz Pr1 Pr2 immer dem Wert des Set Points entspricht Der Unterschied zwischen den beiden Betriebsarten liegt darin dass die Betriebsart P1 L in dem Regler einen Grenzwert f r die Berechnung der Temperaturdifferenz aktiviert der auf den Parametern P2HL und P2LL beruht beide sind in der Gruppe SP enthalten damit der Regler wenn Pr2 gt P2HL von einem Prozesswert Pr1 P2HL ausgeht der Regler wenn Pr2 lt P2HLL von einem Prozesswert Pr1 P2LL ausgeht Wenn die Temperatur Pr2 die festgelegten Schwellenwerte P2HL und P2LL berschreitet wird die Regelung so ausgef hrt als ob die Temperatur Pr2 unabh ngig von dem tats chlich erfassten Wert der Schwellenwert w re Mit dieser Funktion soll die Differenzregelung auf einen maximalen Messbereich Pr2 begrenzt werden Bei der Differenzregelung wird die Betriebsart Func CooL f r die Anwendungen eingesetzt bei denen sich die Differenz Pr1 Pr2 durch die Wirkung des Stellantriebs verringert und sich folglich dem nat rlichen
44. 4 10 SOFT START FUNKTION Alle Parameter des Soft Start Betriebs befinden sich in der Gruppe EG Die Soft Start Funktion ist nur bei vorhandener PID Regelung aktivierbar und gestattet eine Einschr nkung der Regelleistung bei Einschaltung des Ger tes w hrend einer vorgegebenen Zeit Dies ist dann n tzlich wenn der vom Ger t angesteuerte Verbraucher durch eine zu hohe Leistung besch digt werden k nnte die abgegeben wird wenn er noch nicht hochgefahren ist z B im Fall von einigen Heizelementen Der Betrieb wird durch die folgenden Parameter bestimmt St P Soft Start Leistung SSt Max Soft Start Zeit angegeben in hh mm HSEt Ausschaltung Zyklus Soft Start pflegt Gliedert einmal zu den gew nschten Werten der Z ndung die Parameter das Ger t es wird sorgen im Ausgang die zum Abs gegliederte Macht St P f r die zum Abs gegliederte Zeit SSt zu liefern oder bis zur Erreichung des absoluten Wertes gegliedert zum Abs HSEt Darin bt das Ger t Werk in manueller Regelung aus um automatisch in automatischer Regelung am Ende die Zeit SSt auszutauschen oder wenn der Wert von Proze zum zum Abs programmierten Wert HSEt gleich ist Zur Abschaltung der Soft Start Funktion ist der Parameter SSt OFF zu stellen TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 8 Tritt w hrend der Durchf hrung des Soft Start ein Messfehler auf wird die Funktio
45. ALE Il modello TLK 31 D un termoregolatore digitale a microprocessore single loop con regolazione ON OFF ON OFF a Zona Neutra PID a singola azione o PID a doppia azione diretta e inversa dotato di due ingressi per sonde di temperatura di tipo PTC o NTC attraverso i quali possibile realizzare la regolazione differenziale di temperatura ed pertanto utilizzabile nelle applica zioni che richiedono un controllo in funzione della differenza di tem peratura tra due diversi ambienti come ad esempio raffreddatori di fluido chiller sistemi di climatizzazione naturale degli ambienti attraverso il ricircolo dell aria riscaldamento attraverso pannelli solari termici o comunque in molte altre applicazioni dove sono richieste due misure di temperatura Il regolatore inoltre dotato delle funzioni di AUTOTUNING Fast e Oscillatorio SELFTUNING e FUZZY OVERSHOOT CONTROL per la regolazione PID Lo strumento offre la possibilit di disporre di due ingressi digitali programmabili e di interfaccia di comunicazione seriale RS485 con protocollo di comunicazione MODBUS RTU e con velocit di trasmissione sino a 38400 baud TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 1 Il valore di processo viene visualizzato su 4 display rossi mentre lo stato delle uscite viene segnalato da 4 led L apparecchio dispone inoltre di un indicatore di scostamento programmabile costituito da 3 led Lo strumento prevede l
46. ARAMETER 2 3 PROGRAMMIEREBENEN DER PARAMETER 24 REGELZUSTANDE 2 5 WAHL DES AKTIVEN SOLLWERTES 3 HINWEISE ZUR INSTALLATION UND ZUM GEBRAUCH 3 1 BESTIMMUNGSGEMASSER GEBRAUCH 3 2 MECHANISCHER EINBAU 3 3 ELEKTRISCHE ANSCHL SSE 3 4 ANSCHLUSSPLAN 4 BETRIEB 4 1 MESSUNG UND ANZEIGE 4 2 KONFIGURATION DER AUSGANGE 4 3 WARMEREGLER MIT ABSOLUTER TEMPERATUR ODER TEMPERATURDIFFERENZ 44 EIN AUS REGELUNG 4 5 EIN AUS REGELUNG BEI NEUTRALER ZONE 46 PID REGELUNG MIT EINFACHER WIRKUNG 4 7 PID REGELUNG MIT DOPPELTER WIRKUNG 4 8 AUTOTUNING UND SELFTUNING FUNKTIONEN 49 ERREICHEN DES SOLLWERTES BEI VORGEGEBENER GESCHWINDIGKEIT UND AUTOMATISCHE UMSCHALTUNG ZWISCHEN ZWEI SOLLWERTEN 4 10 SOFT START FUNKTION 4 11 BETRIEB DER ALARME 4 11 1 KONFIGURATION DER ALARMAUSG NGE 4 11 2 ALARMHYSTERESE 4 12 FUNKTION DES LOOP BREAK ALARMS 4 13 FUNKTION DER TASTE U 4 14 DIGITALER EINGANGE 4 15 SERIELLE SCHNITTSTELLE RS 485 4 16 KONFIGURATION DER PARAMETER MIT KEY 01 oder A01 5 PROGRAMMIERBARE PARAMETER 6 ST RUNGEN WARTUNG UND GARANTIE 6 1 FEHLERMELDUNGEN 6 2 REINIGEN 6 3 GEW HRLEISTUNG UND INSTANDSETZUNG 7 TECHNISCHE DATEN 7 14 ELEKTRISCHE MERKMALE 7 2 MECHANISCHE MERKMALE 7 3 MECHANISCHE EINBAUMASSE DURCHBOHREN DER TAFEL UND BEFESTIGUNG 7 4 FUNKTIONSMERKMALE 75 TABELLE DER MESSBEREICHE 76 CODIERUNG DES GER TES 1 BESCHREIBUNG DES GER TES 1 1 ALLGEMEINE BESCHREIBUNG Das Modell TLK 31 D ist ein digitaler Warmeregler mit S
47. Alarmgrenzwerte sind editierbar 2 4 REGELZUST NDE Der Regler kann 3 verschiedene Zust nde annehmen Automatische Regelung rEG Regelung deaktiviert OFF und Handregelung OPLO Das Ger t kann von einem Regelzustand in den anderen bergehen ber die Tastatur durch anw hlen des gew nschten Zustands im Hauptmen ber die Tastatur durch Dr cken der Taste U und entsprechende Programmierung des Parameters USrb USrb tunE USrb OPLO USrb OFF kann vom Zustand rEG zu dem im Parameter programmierten Zustand bergegangen werden und umgekehrt Mit entsprechender Programmierung des Parameters diF diF OFF kann ber den Digitaleingang 1 von Zustand rEG auf Zustand OFF umgeschaltet werden Automatisch das Ger t versetzt sich nach Abschluss des Autotuning Vorgangs in den Zustand rEG Bei Einschaltung versetzt sich das Ger t automatisch in den Zustand in dem es sich vor der Abschaltung befand AUTOMATISCHE REGELUNG rEG Der automatische Regelzustand ist der normale Betriebszustand des Reglers W hrend der automatischen Regelung kann die Regelleistung durch Dr cken der Taste UP angezeigt werden F r die Leistung k nnen die Werte H100 100 Leistung am Ausgang mit umgekehrter Wirkung und C100 100 Leistung am Ausgang mit direkter Wirkung angezeigt werden DEAKTIVIERTE REGELUNG OFF Der Regler kann in den OFF Zustand versetzt werden d h
48. DI MANTENIMENTO Tutti i parametri riguardanti il funzionamento delle rampe sono contenuti nel gruppo IrEG E possibile fare in modo che il Set point venga raggiunto in un tempo predeterminato comunque maggiore del tempo che il siste ma impiegherebbe naturalmente Questo pu essere utile in quei processi trattamenti termici chimi ci ecc in cui il Set point deve essere raggiunto gradatamente in tempi prestabiliti Inoltre possibile fare in modo che dopo l accensione dello stru mento raggiunto il primo Set SP1 lo strumento commuti TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 7 automaticamente sul secondo Set SP2 dopo un tempo program mabile realizzando cosi un ciclo automatico Queste funzioni sono disponibili per tutti i tipi di regolazione pro grammabili Il funzionamento stabilito dai seguenti parametri SLor Pendenza della prima rampa espressa in unit minuto SLoF Pendenza della seconda rampa espressa in unit minuto dur t Tempo di mantenimento del Set Point SP1 prima di commutare automaticamente su SP2 espresso in ore e min Le funzioni risultano disattivate quando si impostano i relativi para metri InF Se si desidera il solo raggiungimento del Set Attivo es SP1 a velocit controllata sufficiente impostare il par SLor al valore desiderato La rampa SLor risulter sempre operativa all accensione d
49. G ein wenn der Istwert h her ist als SP HSEt Folglich muss das Element das den positiven Anstieg erzeugt an den als 1 rEG konfigurierten Ausgang und das Element das den negativen Anstieg erzeigt an den als 2 rEG konfigurierten Ausgang angeschlossen werden Wurde der Ausgang 2 rEG als Kompressorschaltung verwendet ist die Funktion Compressor Protection Verdichterschutz vorgesehen diese Funktion hat die Aufgabe ein st ndiges Ein und Ausschalten des Verdichters zu vermeiden Die Funktion bewirkt eine Zeitschaltung bei Aktivierung von Ausgang 2 rEG die unabh nging von der Austeuerung des Temperaturreglers ist TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 Beider Schutzart handelt es sich um eine Abschaltverz gerung Der Schutz besteht darin dass der Ausgang w hrend einer im Parameter CPdt angegeben in Sekunden vorgegebenen Zeit die nach der letzten Abschaltung des Ausgangs beginnt aktiviert wird d h eine m gliche Aktivierung kann erst nach Ablauf der Zeit CPdt erfolgen Sollte w hrend der Aktivierverz gerung wegen Hemmung der Funktion Cpmpressor Protection keine Ansteuerung des Reglers erfolgen wird die Aktivierung des Ausgangs nat rlich aufgehoben Die Funktion wird durch Programmierung von CPdt OFF deaktiviert W hrend aller Phasen der Aktivierverz gerungdes Ausgangs zur Hemmung der Funktion Compressor Protection blinkt die Led von des Ausgangs 2 rEG OU
50. Ger t gestattet hierzu wird die Einrichtung TECNOLOGIC KEY01 oder A01 mit 5 poligem Steckverbinder verwendet Diese Einrichtung wird zur serienm igen Programmierung von Ger ten verwendet die alle ber die gleiche Parameterkonfiguration verf gen sollen bzw zur Sicherung einer Kopie der Programmierung eines Ger tes damit diese schnell wiederhergestellt werden kann Bei Verwendung der KEY 01 oder A01 Einrichtung kann auch nur die Einrichtung oder nur das Ger t gespeist werden Gespeistes Ger t und nicht gespeiste Einrichtung KEY 01 SUPPLY A dalai gt q p g o b d b d b d p q Von der Einrichtung gespeistes Ger t FONBSOSESOSE S H SUPPLY ADAPTER 12 VDC AC SUPPLY Hinweis Bei Ger ten die ber den seriellen Kommunikationsport RS485 verf gen muss der Parameter PACS auf LorE stehen F r weitere Informationen und Hinweise zu Fehlerursachen siehe entsprechende Bedienungsanleitung der KEY 01 oder A01 Einrichtung 5 PROGRAMMIERBARE PARAMETER Nachstehend werden alle Parameter beschrieben ber die das Ger t verf gt Es wird darauf hingewiesen dass einige Parameter m glicherweise nicht angezeigt werden dies liegt entweder an dem verwendeten Ger tetyp oder an der Tatsache dass die betreffenden Parameter
51. HEAt Die Funktion ist nur bei nSP 2 verf gbar wenn sie aktiviert ist die Auswahl des aktiven Sollwerts ber den Parameter SPAt und die Taste U 4 15 SERIELLE SCHNITTSTELLE RS 485 Das Ger t kann mit einer seriellen Kommunikationsschnittstelle Typ RS 485 ausgestattet werden mit Hilfe dieser Schnittstelle kann das Ger t an ein Kommunikationsnetzwerk angeschlossen werden an dem auch andere Ger te Regler oder SPS angeschlossen sind und von einem Personal Computer als Anlagen berwachung gesteuert werden Der Personal Computer erfasst alle Betriebsdaten und erm glicht eine Programmierung aller Konfigurationsparameter des Ger tes Das im TLK 31 D verwendete Softwareprotokoll ist ein MODBUS RTU Protokoll das in zahlreichen SPS und in auf dem Markt erh ltlichen berwachungsprogrammen verwendet wird die Bedienungsanleitung des Kommunikationsprotokolls der Baureihe TLK ist auf Anfrage erh ltlich Der Schnittstellenkreislauf erm glicht den Anschluss von bis zu 32 Ger ten am gleichen Netz Um das Netz in Ruhestellung zu belassen ist ein 120 Ohm Widerstand Rt am Leitungsende anzuschlie en Das Ger t ist mit zwei Klemmen A und B genannt versehen die an die entsprechenden Klemmen in der Leitung anzuschlie en sind F r den Netzanschluss ist eine verflochtene Telefonkabelschleife zu verwenden Insbesondere bei einer sehr langen bzw gest rten Leitung und bei Leistungsunterschieden zwischen den Klemmen GND
52. Hinweis Ihm wird zum Alarm Bezug ALT in alle Beispiele gemacht die folgen Nat rlich erweist das Funktionieren der anderen Alarme sich als analog Die Gruppe AL1 des zu konfigurierenden Alarms ffnen und bei dem Parameter OAL1 programmieren f r welchen Ausgang das Alarmsignal bestimmt werden soll Der Alarmbetrieb wird durch die nachstehenden Parameter festgelegt PrA1 PROZESSWERT ALARM AL1t ALARMART Ab1 ALARMKONFIGURATION AL1 ALARMGRENZWERT AL1L UNTERER ALARMGRENZWERT f r Bandwert Alarme ODER TIEFSTER ALARMGRENZWERT SOLLWERT f r tiefstwertalarm und h chstwertalarm AL1H OBERER ALARMGRENZWERT f r Bandwert Alarme ODER H CHSTER ALARMGRENZWERT SOLLWERT f r tiefstwertalarm und h chstwertalarm AL1d ALARMEINSCHALTVERZ GERUNG in sec AL1i ALARMVERHALTEN BEI MESSFEHLER PrA1 PROZESSWERT ALARM Mit diesem Parameter kann die Prozessvariable f r den Alarm eingestellt werden Der Alarm kann als Prozessvariable den Wert der am Eingang 1 Pr1 oder am Eingang 2 Pr2 gemessen wurde oder die Temperaturdifferenz zwischen beiden Eing ngen Pr1 Pr2 P1 2 verwenden oder er geht von der Differenz der beiden Eing nge Pr1 Pr2 aus und legt einen H chstwert und einen Mindestwert f r die Messung Pr2 P1 L zugrunde AL1t ALARMART Es bestehen bis zu 6 verschiedene Verhalten des Alarmausgangs LoAb ABSOLUTER TIEFSTWERTALARM Der
53. ISATTIVATA OFF Lo strumento pu essere messo in stato di OFF il che significa che la regolazione e le relative uscite vengono disattivate Le uscite di allarme invece risultano normalmente operative REGOLAZIONE MANUALE BUMPLESS OPLO Tramite questa opzione possibile impostare manualmente la percentuale di potenza fornita in uscita dal regolatore disattivando la regolazione automatica Quando lo strumento viene messo in regolazione manuale la percentuale di potenza attuata l ultima fornita in uscita e pu essere editata mediante i tasti UP e DOWN In caso di regolazione di tipo ON OFF lo 0 corrisponde all uscita disattivata mentre un qualsiasi valore diverso da 0 corrisponde all uscita attivata Come nel caso della visualizzazione i valori impostabili per la potenza variano da H100 100 a C100 100 Per riportare il regolatore nello stato di regolazione automatica selezionare rEG nel men di selezione 2 5 SELEZIONE DEL SET POINT ATTIVO Lo strumento permette di preimpostare fino a 4 diversi Set point di regolazione SP1 SP2 SP3 SP4 e poi di selezionare quale rendere attivo Il numero massimo di set point viene determinato dal parametro nSP nel gruppo di parametri SP Il set point attivo pu essere selezionato Attraverso il parametro SPAt nel gruppo di parametri SP TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 3
54. Int Integralzeit rS manuelle R cksetzung nur bei Int 0 dEr Vorhaltezeit FuOC Fuzzy Overshoot Control Prat Power Ratio oder Verh ltnis zwischen der Leistung des vom Ausgang 2 rEG angesteuerten Elements und der Leistung des vom Ausgang 1 rEG angesteuerten Elements 4 8 AUTOTUNING UND SELFTUNING FUNKTIONEN Alle Parameter der AUTOTUNING und SELFTUNING Funktionen befinden sich in der Gruppe IrEG Die AUTOTUNING Funktion und die SELTUNING Funktion gestatten eine automatische Einstellung des PID Reglers Die Funktion AUTOTUNING sieht die Berechnung der PID Parameter in einem Abstimmzyklus vom Typ FAST oder OSZILLIEREND vor nach Abschluss des Zyklus werden die Parameter vom Ger t gespeichert und bleiben w hrend der Regelung konstant Die SELFTUNING Funktion rule based TUNE IN beinhaltet hingegen die Steuerung der Regelung und eine fortw hrende Neuberechnung der Parameter w hrend der Regelung Beide Funktionen berechnen automatisch die Parameter Pb Proportionalband tcr1 Zykluszeit von Ausgang 1 rEG Int Integralzeit dEr Vorhaltezeit FuOC Fuzzy Overshoot Control und f r die PID Regelung mit doppelter Wirkung auch ter2 Zykluszeit von Ausgang 2 rEG Prat Das Verh ltnis P 2 rEG P 1 rEG folgenden Zur Aktivierung der AUTOTUNING Funktion ist wie folgt beschrieben vorzugehen 1 Den gew nschten Sollwert einstellen und aktivieren 2
55. LE 1 2 DESCRIZIONE PANNELLO FRONTALE 2 PROGRAMMAZIONE 2 1 IMPOSTAZIONE RAPIDA DEI SET POINT 2 2 SELEZIONE DEGLI STATI DI REGOLAZIONE E PROGRAMMAZIONE DEI PARAMETRI 2 3 LIVELLI DI PROGRAMMAZIONE PARAMETRI 2 4 STATI DI REGOLAZIONE 2 5 SELEZIONE DEL SET POINT ATTIVO 3 AVVERTENZE PER INSTALLAZIONE ED USO 3 1 USO CONSENTITO 3 2 MONTAGGIO MECCANICO 3 3 COLLEGAMENTO ELETTRICO 3 4 SCHEMA ELETTRICO DI COLLEGAMENTO 4 FUNZIONAMENTO 4 1 MISURA E VISUALIZZAZIONE 4 2 CONFIGURAZIONE DELLE USCITE 4 3 REGOLATORE CON TEMPERATURA ASSOLUTA O DIFFERENZIALE 4 4 REGOLATORE ON OFF 4 5 REGOLATORE ON OFF A ZONA NEUTRA 4 6 REGOLATORE PID A SINGOLA AZIONE 4 7 REGOLATORE PID A DOPPIA AZIONE 4 8 FUNZIONI DI AUTOTUNING E SELFTUNING 4 9 RAGGIUNGIMENTO DEL SET POINT A VELOCITA CONTROLLATA E COMMUTAZIONE AUTOMATICA TRA DUE SET POINT 4 10 FUNZIONE DI SOFT START 4 11 FUNZIONAMENTO DEGLI ALLARMI 4 12 FUNZIONE ALLARME DI LOOP BREAK 4 13 FUNZIONAMENTO DEL TASTO U 4 14 INGRESSI DIGITALI 4 15 INTERFACCIA SERIALE RS 485 4 16 CONFIGURAZIONE PARAMETRI CON KEY 01 O A01 5 PARAMETRI PROGRAMMABILI 6 PROBLEMI MANUTENZIONE E GARANZIA 6 1 SEGNALAZIONI DI ERRORE 6 2 PULIZIA 6 3 GARANZIA E RIPARAZIONI 7 DATI TECNICI 7 1 CARATTERISTICHE ELETTRICHE 7 2 CARATTERISTICHE MECCANICHE 7 3 DIMENSIONI MECCANICHE FORATURA PANNELLO E FISSAGGIO 7 4 CARATTERISTICHE FUNZIONALI 7 5 TABELLA RANGE DI MISURA 7 6 CODIFICA DELLO STRUMENTO 1 DESCRIZIONE STRUMENTO 1 1 DESCRIZIONE GENER
56. LS The menu OPEr normally contains the parameters used to program the Set Point however it is possible to make all desired parameters appear or disappear on this level by following this procedure Enter the menu ConF and select the parameter to be made programmable or not programmable in the menu OPEr Once the parameter has been selected if the LED SET is switched off this means that the parameter is programmable only in the menu ConF if instead the LED is on this means that the parameter is also programmable in the menu OPEr To modify the visibility of the parameter push key U the LED SET will change its state indicating the parameter accessibility level on menu OPEr and ConF off menu ConF only The active Set Point and the alarm thresholds will only be visible on the Set Point fast programming level described in par 2 1 if the relative parameters are programmed to be visible i e if they are present in the menu OPEr The possible modification of these Sets with the procedure described in par 2 1 is instead subordinate to what is programmed in par Edit contained in the group PAn This parameter can be programmed as SE The active Set Point can be modified while the alarm thresholds cannot be modified AE The active Set Point cannot be modified while the alarm thresholds can be modified SAE Both the active Set Point and the alarm
57. LorE it is programmable both from the keyboards and serial line If an attempt is made to enter the programming from the keyboard whilst a communication through the serial port is in progress the instrument will visualise buSy to indicate the busy state HOST PC PLC shield A Rt B 120 ohm GN RS485 Interface A B GND A B GND A B GND 1018 9 10 8 9 10 8 9 TLK31 n 1 TLK31 n 2 TLK31 n N 4 16 PARAMETERS CONFIGURATION BY KEY01 and A01 The instrument is equipped with a connector that allows the trans fer from and toward the instrument of the functioning parameters through the device TECNOLOGIC KEY01 or TECNOLOGIC A01 with 5 poles connector This device it s mainly useable for the serial programming of the instruments which need to have the same parameters configuration or to keep a copy of the programming of an instrument and allow its rapid retransmission To use the device KEY01 or A01 it s necessary that the device or instrument are being supplied Instrument supplied and device not supplied SUPPLY Usage eng S 7 oJ B d P d B d p q Instrument supplied from the device
58. NTROL 46 SINGLE ACTION PID CONTROL 4 7 DOUBLE ACTION PID CONTROL 4 8 AUTO TUNING AND SELF TUNING FUNCTIONS 49 REACHING OF SET POINT AT CONTROLLED SPEED AND AUTOMATIC COMMUTATION BETWEEN TWO SET POINTS 4 10 SOFT START FUNCTION 4 11 ALARM FUNCTIONS 4 12 LOOP BREAK ALARM FUNCTION 4 13 FUNCTION OF KEY U 4 14 DIGITAL INPUT 4 15 RS 485 SERIAL INTERFACE 4 16 PARAMETERS CONFIGURATION BY KEY01 or A01 5 PROGRAMMABLE PARAMETERS 6 PROBLEMS MAINTENANCE AND GUARANTEE 6 1 ERROR SIGNALLING 6 2 CLEANING 6 3 GUARANTEE AND REPAIRS 7 TECHNICAL DATA 7 1 ELECTRICAL DATA 7 2 MECHANICAL DATA 7 3 MECHANICAL DIMENSIONS PANEL CUT OUT AND MOUNTING 7 4 FUNCTIONAL DATA 7 5 MEASUREMENT RANGE TABLE 76 INSTRUMENT ORDERING CODE 1 INSTRUMENT DESCRIPTION 1 1 GENERAL DESCRIPTION The TLK 31D model is a digital thermoregulator with a single loop microprocessor with ON OFF regulation Neutral Zone ON OFF single or double action PID direct and inverse fitted with two inputs for PTC or NTC temperature probes by means of which it is possible to obtain differential temperature regulation It can therefore be used in applications that require a control for the temperature difference between two different environments such as liquid coolers chillers natural air conditioning systems through the recirculation of air heating by solar panels or in many other applications where two temperature readings are needed Furthermore the regulator is fitted with Fast an
59. PROGRAMMAZIONE PARAMETRI Il men OPEr contiene normalmente i parametri di impostazione dei Set point tuttavia possibile fare comparire o scomparire a questo livello tutti i parametri desiderati mediante la seguente procedura Accedere al men ConF e selezionare il parametro che si vuole rendere o non rendere programmabile nel men OPEr Un volta selezionato il parametro se il led SET spento significa che il parametro programmabile solo nel men ConF se invece acceso significa che il parametro programmabile anche nel men OPEr Per modificare la visibilit del parametro premere il tasto U il led SET cambier stato indicando il livello di accessibilit del parametro acceso men OPEr e ConF spento solo men ConF AI livello di impostazione rapida dei Set Point descritto al par 2 1 saranno resi visibili il Set Point Attivo e le soglie di allarme solo se i relativi parametri sono configurati come operativi sono cio presenti nel men OPEr La possibile modifica di questi Set con la procedura descritta al par 2 1 invece subordinata a quanto programmato al par Edit contenuto nel gruppo PAn Questo parametro pu essere impostato come SE II Set point attivo risulta editabile mentre le soglie di allarme non sono editabili AE Il Set point attivo risulta non editabile mentre le soglie di allarme sono editabili SAE Sia il S
60. Qualora un guasto o un malfunzionamento dell apparecchio possa creare situazioni pericolose o dannose per persone cose o animali si ricorda che l impianto deve essere predisposto con dispositivi elettromeccanici aggiuntivi atti a garantire la sicurezza 3 2 MONTAGGIO MECCANICO Lo strumento in contenitore 78 x 35 mm concepito per il montaggio ad incasso a pannello entro un involucro Praticare quindi un foro 71 x 29 mm ed inserirvi lo strumento fissandolo con le apposite staffe fornite Si raccomanda di montare l apposita guarnizione per ottenere il grado di protezione frontale dichiarato Evitare di collocare la parte interna dello strumento in luoghi soggetti ad alta umidit o sporcizia che possono provocare condensa o introduzione nello strumento di parti o sostanze conduttive Assicurarsi che lo strumento abbia una adeguata ventilazione ed evitare l installazione in contenitori dove sono collocati dispositivi che possano portare lo strumento a funzionare al di fuori dai limiti di temperatura dichiarati Installare lo strumento il pi lontano possibile da fonti che possono generare disturbi elettromagnetici come motori teleruttori rel elettrovalvole ecc 3 3 COLLEGAMENTI ELETTRICI Effettuare le connessioni collegando un solo conduttore per morsetto e seguendo lo schema riportato controllando che la tensione di alimentazione sia quella indicata sullo strumento e che l assorbimento degli attuatori collegati allo strumento non s
61. Range Def Note 9 SEnS Probes type Ptc ntc ntc 10 Pr2 Probe Pr2 presence yES no yES 11 dP Number of decimal 0 1 0 figures 12 Unit Temperature unit of C F C measurement 13 FiL Input digital filter OFF 20 0 1 0 sec 14 OFS1 Measuring Offset Pr1 1999 9999 0 15 OFS2 Measuring Offset Pr2 1999 9999 0 16 rot Rotazione della retta di 0 000 2 000 1 000 misura 17 InE OPE functioning in Our Or Ur OUr case of measuring error 18 OPE Output power in case of 100 100 0 measuring error 19 diF Digital inputs function noF AaC noF noF No Function ASI Hold Aac Reset Alarms OFF CHSP latch SP1 2 ASi Aknowledged HE Co Alarms HoLd Hold Measure OFF Control OFF CHSP Sel Set Point SP1 2 Sel SP1 SP2 HE Co Sel Heat SP1 Cool SP2 Group Out parameters relative to the outputs Par Description Range Def Note 20 O1F Functioning of output 1 1 rEG 2 rEG 1 rEG 1 rEG Control output 1 ALno ALnc 2 rEG Control output 2 ALni OFF ALno Alarm Out nor mally opened ALnc Alarm Out nor mally closed ALni Alarm Out nor mally closed with rever se led func 21 O2F Functioning of output 2 1 rEG 2 rEG ALno see 01F ALno ALnc ALni OFF 22 O3F Functioning of output 3 1 rEG 2 rEG ALno see 01F ALno ALnc ALni OFF 23 O4F Functioning of output 4 1 rEG 2 rEG ALno see O1F ALno ALnc ALni OFF Group AL1 para
62. Regelung und entsprechende Ausg nge werden deaktiviert Die Alarmausg nge funktionieren jedoch normal weiter HANDREGELUNG BUMPLESS OPLO Durch diese Option kann nach Deaktivierung der Automatikregelung von Hand der Prozentanteil der am Ausgang vom Regler abgegebenen Leistung eingestellt werden Wenn das Ger t in die Handregelung versetzt wird ist der Prozentanteil der ausgef hrten Leistung die zuletzt am Ausgang abgegebene Leistung und kann anhand der Tasten UP und DOWN verstellt werden Bei Regelung EIN AUS entspricht der Wert 0 dem deaktivierten Ausgang w hrend ein beliebiger von 0 verschiedener Wert einem aktivierten Ausgang entspricht TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 3 Genau wie bei der Anzeige k nnen f r die Leistung die Werte H100 100 und C100 100 eingegeben werden Im Wahlmen rEG anw hlen um den Regler wieder in den automatischen Regelmodus zu versetzen 2 5 WAHL DES AKTIVEN SOLLWERTES Im Regler k nnen bis zu 2 verschiedene Sollwerte eingestellt werden SP1 SP2 daraufhin kann bestimmt werden welcher Sollwert aktiviert werden soll Die H chstzahl der Sollwerte wird im Parameter nSP in der Parametergruppe SP bestimmt Der aktive Sollwert kann gew hlt werden Durch den Parameter SPAt in der Parametergruppe SP Durch Dr cken der Taste U wenn der Parameter USrb CHSP ber den entsprechend programmierten D
63. SR verwendet werden Weitere wichtige Funktionen sind Loop Break Alarmfunktion Erreichen des Sollwertes bei berwachter Geschwindigkeit Steuerung in zwei Schritten bei durchschnittlicher Erhaltungszeit Soft Start Funktion Kompressorschutz Funktion f r Regelung bei Neutral Zone Parameterschutz auf verschiedenen Ebenen 1 2 BESCHREIBUNG DER FRONTTAFEL 1 Taste P Wird f r den Zugriff auf den Programmiermodus der Betriebsparameter und zur Eingabebest tigung verwendet 2 Taste DOWN Anhand dieser Taste wird der einzustellende Wert reduziert bzw ein Parameter angew hlt Wird die Taste gedr ckt gehalten geht man zur vorangegangenen Programmierebene zur ck bis der Programmiermodus verlassen wird 3 Taste UP Anhand dieser Taste wird der einzustellende Wert erh ht bzw ein Parameter angew hlt Wird die Taste gedr ckt gehalten geht man zur n chsten Programmierebene ber bis der Programmiermodus verlassen wird Befindet man sich nicht im Programmiermodus wird anhand dieser Taste die Regelleistung am Ausgang angezeigt 4 Taste U Bei Bet tigen dieser Taste werden die von den F hlern Pr1 und Pr2 erfassten Temperaturen und deren Differenz Pr1 Pr2 angezeigt Au erdem kann die Taste ber den Parameter USrb f r folgende Funktionen programmiert werden Autotuning oder Selftuning einschalten manuelle Regelung f r das Ger t einschalten Alarm ausschalten aktiven Set Point ndern Regelu
64. ST venga avviato automati camente all accensione successiva dello strumento a condizione che il valore di processo sia minore per Func HEAt di SP SP 2 o maggiore per Func CooL di SP SP 2 e una volta terminata la sintonizzazione venga posto automaticamente il par Auto OFF 3 se si desidera avviare l autuning FAST manualmente median te la selezione della voce tunE nel menu principale o mediante il tasto U opportunamente programmato USrb tunE In questo caso l autotuning parte a condizione che il valore di processo sia minore per Func HEAt di SP SP 5 o maggiore per Func CooL di SP SP 5 4 se si desidera che l autotuning FAST venga avviato automati camente ad ogni modifica del Set di regolazione o al termine del ci clo di Soft Start programmato L autotuning verra comunque ese guito a condizione che il valore di processo sia minore per Func HEAt di SP SP 5 o maggiore per Func CooL di SP SP 5 1 se si desidera che l autotuning OSCILLATORIO venga av viato automaticamente ogni volta che si accende lo strumento 2 se si desidera che l autotuning OSCILLATORIO venga av viato automaticamente all accensione successiva dello strumento e una volta terminata la sintonizzazione venga posto automatica mente il par Auto OFF 3 se si desidera avviare l autuning OSCILLATORIO manual mente mediante il ta
65. T DIFFERENZREGELUNG Tl 2 000 BEDIENUNGSANLEITUNG Vr 02 DEU cod ISTR MTLK31DDEU2 TECNOLOGIC S p A VIA INDIPENDENZA 56 27029 VIGEVANO PV ITALY TEL 39 0381 69871 FAX 39 0381 698730 internet http www tecnologic it e mail info tecnologic it VORTWORT In der vorliegenden Anleitung sind alle Angaben enthalten die f r eine einwandfreie Installation und Verwendung sowie Wartung des Produktes erforderlich sind Daher sollten die nachstehenden Anweisungen aufmerksam gelesen werden Alle Rechte der vorliegenden Unterlagen sind vorbehalten Nachdruck auch auszugsweise verboten soweit nicht ausdr cklich zuvor von TECNOLOGIC S p A genehmigt TECNOLOGIC S p A beh lt sich das Recht vor jederzeit ohne besondere Anzeige jene nderungen vorzunehmen die sie als notwendig erachtet Falls eine Betriebsst rung des Ger tes Personen oder Sachsch den verursachen kann muss die Anlage mit zus tzlichen elektromechanischen Schutzeinrichtungen abgesichert werden Die Firma Tecnologic S p A und ihre gesetzlichen Vertreter weisen jede Haftung f r Personen oder Sachsch den von sich die auf Ab nderungen unsachgem e falsche oder nicht den Merkmalen des Ger tes entsprechende Verwendung zur ckzuf hren sind NHALT 1 BESCHREIBUNG DES GER TES 1 ALLGEMEINE BESCHREIBUNG 2 BESCHREIBUNG DER FRONTTAFEL 2 PROGRAMMIERUNG 2 1 SCHNELLEINSTELLUNG DER SOLLWERTE 2 2 WAHL DER REGELZUSTANDE UND PROGRAMMIERUNG DER P
66. T 1 Ea heating 7 OUT 2 rEG cooling 4 6 PID REGELUNG MIT EINFACHER WIRKUNG 1rEG Alle Parameter der PID Regelung befinden sich in der Gruppe EG Die PID Regelung mit einfacher Wirkung wird aktiviert indem der Parameter Cont Pid gestellt wird und wirkt auf den Ausgang 1rEG nach dem aktiven Sollwert SP der Betriebsart FunC und dem Ergebnis des 2 stufigen PID Regelalgorithmus des Ger tes PV SP OUT 1 rEG HEat teri ter1 ter1 ter1 tcer1 tcri tert Zur Gew hrleistung einer guten Stabilit t der Variable bei schnellen Abl ufen muss als Zykluszeit tcr1 niedrig sein und der Regelausgang h ufig ansprechen In diesem Fall sollte ein Statikrelais SSR zur Steuerung des Verbrauchers verwendet werden F r den PID Regelalgoritmus mit einfacher Wirkung des Ger tes k nnen die folgenden Parameter eingestellt werden Pb Proportionalband tcr1 Zykluszeit von Ausgang 1 rEG Int Integralzeit rS manuelle R cksetzung nur bei Int 0 dEr Vorhaltezeit FuOC Fuzzy Overshoot Control Durch diesen letzen Parameter k nnen berschwingungen der Variable overshoot bei Einschaltung des Prozesses bzw bei nderung des Sollwertes vermieden werden Hierbei ist jedoch zu ber cksichtigen dass ein niedriger Parameterwert das Overshoot reduziert w hrend es ein hoher Wert erh ht ISTR MTLK31DDEU2 PAG 6 1 Wert FuOC OK 2 We
67. a memorizzazione di 4 Set Point di regolazione e pu avere sino a 4 uscite a rel o per il pilotaggio di rel statici SSR Altre importanti funzioni presenti sono funzione di Loop Break Alarm Raggiungimento Set Point a velocit controllata controllo a due spezzate con tempo di mantenimento intermedio funzione di Soft Start funzione di protezione compressore per controllo a zona neutra protezione parametri con password personalizzabile e gestione parametri su vari livelli 1 2 DESCRIZIONE PANNELLO FRONTALE TLK31D 1 Tasto P Utilizzato per accedere alla programmazione dei parametri di funzionamento e per confermare la selezione 2 Tasto DOWN Utilizzato per il decremento dei valori da impostare e per la selezione dei parametri Se mantenuto premuto consente inoltre di passare al precedente livello di programmazione sino ad uscire dalla modalit di programmazione 3 Tasto UP Utilizzato per l incremento dei valori da impostare e per la selezione dei parametri Se mantenuto premuto consente inoltre di passare al precedente livello di programmazione sino ad uscire dalla modalit di programmazione Quando non ci si trova in modalit di programmazione consente di visualizzare la potenza di regolazione in uscita 4 Tasto U Utilizzato per visualizzare le temperature misurate dalle sonde Pri e Pr2 e la loro differenza Pr1 Pr2 Inoltre pu essere program mato tramite il par USrb per At
68. alarm conditions 8 ALARM AKNOWLEDGED The alarm is active in alarm conditions and can be deactivated by key U if properly programmed USrb ASi and also if alarm conditions still exist ALARM BEHAVIOUR AT SET POINT CHANGE DEVIATION ALARMS ONLY the alarm output may behave in two different ways depending on the value added to par Ab1 0 NORMAL BEHAVIOUR The alarm is always activated when there are alarm conditions 16 ALARM NOT ACTIVATED AT SET POINT CHANGE If when Set Point change the instrument is in alarm condition the alarm is not activated It will be activated only when the process value is in non alarm conditions and then back in alarm conditions AL1i ALARM ACTIVATION IN CASE OF MEASUREMENT ERROR This allows one to establish how the alarm have behave in the event of a measurement error yES alarm active no alarm deactivated 4 12 LOOP BREAK ALARM FUNCTION All the parameters referring to the Loop Break alarm function are contained in the group ILbA The Loop Break alarm is available on all the instruments which intervenes when for any reason short circuit of a thermocouple thermocouple inversion load interruption the loop control is interrupted First of all it is necessary to establish to which output the alarm has to correspond To do this it is necessary to set the parameter relative to the output to be used O1F 02F O3F O4F in the gr
69. allarme AL1 AL2 o AL3 4 3 REGOLATORE CON TEMPERATURA ASSOLUTA O DIFFERENZIALE Attraverso il par PrrG possibile stabilire la variabile di proces so utilizzata dal regolatore per operare Il regolatore pu infatti operare considerando come variabile di pro cesso il valore misurato dall ingresso 1 Pr1 il valore misurato dal l ingresso 2 Pr2 oppure pu considerare la differenza tra i 2 ingressi Pr1 Pr2 P1 2 La selezione PrrG P1 2 porta il regolatore ad operare come re golatore differenziale In questo caso il regolatore agisce sulle uscite di regolazione in modo da mantenere la differenza Pr1 Pr2 pari al valore del Set Point Il modo di funzionamento Func CooL viene utilizzato per le applicazioni in cui l azione dell attuatore fa diminuire la differenza Pr1 Pr2 contrastando quindi la differenza Pri Pr2 che tende naturalmente ad aumentare Viceversa il modo Func HEAt viene utilizzato per le applicazioni in cui l azione dell attuatore fa aumentare la differenza Pr1 Pr2 contrastando quindi la differenza Pr1 Pr2 che tende a diminuire Ovviamente la modalit a Zona Neutra o la doppia azione realizzeranno entrambe le azioni di contrasto Temp SP1 HSEt Esempio di regolazione differenziale ON OFF On FA con Func CooL Attenzione Il regolatore gi programmato in fabbrica per eseguire la regolazione differenziale e visualizzare la differenza
70. antielaufzeit von 12 Monaten auf Baufehler oder Materialm ngel Die Garantie ist begrenzt auf Reparatur bzw Auswechslung des Produktes Das ffnen die eigenst ndige Arbeit am Ger t sowie eine unsachgem e Verwendung bzw Installation des Ger tes f hren automatisch zum Ausschluss der Garantieleistung Bei defektem Produkt innerhalb oder au erhalb der Garantielaufzeit ist die Abteilung Verkauf der Fa TECNOLOGIC zu benachrichtigen um die Erlaubnis zum Versand des Ger tes einzuholen Unter Angabe der aufgetretenen St rung ist das defekte Ger t frachtfrei an die Fa TECNOLOGIC zu senden es sei denn es wurden andere Vereinbarungen getroffen 7 TECHNISCHE DATEN 7 1 ELEKTRISCHE MERKMALE Stromversorgung 12 VAC VDC 10 Frequenz AC 50 60 Hz Aufnahme ca 4 VA F hler 2 Eingang f r Temperaturf hler PTC KTY 81 121 990 Q Fehler Ursache Abhilfe E1 Der F hler Pri kann Den F hleranschluss E1 unterbrochen oder am Ger t und die kurzgeschlossen sein oder Funktionst chtigkeit einen Wert messen der des F hlers au erhalb des zul ssigen berpr fen Bereichs liegt E2 Der F hler Pr2 kann E2 unterbrochen oder kurzgeschlossen sein oder einen Wert messen der au erhalb des zul ssigen Bereichs liegt Prozesswert nicht verf gbar ErAt Autotuning nicht Die Taste P dr cken durchf hrbar da der Istwert um den Fehler zu gr eroder kleiner als beseitigen Das erl
71. arm LbA Out1 Out2 OFF tune Start Autotuning ASi CHSP Out3 Out4 Selftuning OFF OFF OPLO Handregelung 55 LbAt Zeit f r LDA OFF 9999 OFF open loop sec Aac Reset Gruppe rEG Parameter der Regelung gespeicherter Alarm Par Beschreibung Bereich Def Note ASi Alarm quittiert 56 Cont Regelart Pid On FA Pid CHSP Auswahl Pid PID On FS nr Sequenz aktiv Sollwerte On FA EIN AUS asym OFF Zustand OFF On FS EIN AUS 77 diSP Angezeigte Variable Pr1 Pr2 P1 2 symm Pr1 Pr1 variable P1 2 Pou nr EIN AUS Neutrale Pr2 Pr2 variable SP F SP 0 Zone P1 2 Pr1 Pr2 variable AL1 AL2 57 Func Betriebsart Ausgang HEAt CooL HEAt Pou Regelleistung AL3 1 rEG SP F aktive Sollwert HEAt Heizen SP o operative umgekehrtem Sollwert CooL K hlen AL1 Alarmgrenzwert direktem ALI 58 PrrG Prozesswert f r die Pr1 Pr2 Pri AL2 Alarmgrenzwert Regelung P1 2 P1 L AL2 59 HSEt Regelhysterese 0 9999 1 AL3 Alarmgrenzwert EIN AUS und AL3 Ausschaltung Zyklus 78 AdE Abweichungswert f r OFF 9999 2 Soft Start Indexbetrieb 60 CPdt Verz gerungs zeit OFF 9999 0 79 Edit Anderung des aktiven SE AE SAE verdichterschutz 2 rEG sec Sollwertes und der SAE SAnE 61 Auto Aktivierung Fast 4 3 2 1 0 Alarme im Autotuning 0 Schnellverfahren OFF Befahigt nicht 1 2 3 4 SE Aktive Sollwert editierbar Alarmgrenzw nicht editierbar AE Aktive Sollwert nicht editierbar Alarmgrenzwe
72. at the start up of Fuoc Fuzzy Overshoot Control the process or at the changing of the Set Point to be avoided and for the Double Action PID control also TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 6 ter 2 Cycle time of the output 2rEG Prat Ratio P 2 rEG P 1 rEG To activate the AUTO TUNING function proceed as follows 1 Program and activate the desired Set Point 2 Program par Cont Pid 3 Program par Func according to the process to be controlled through output 1rEG 4 Program an output as 2rEG if the instrument controls a plant with double action 5 Program par Auto as 1 if FAST autotuning is desired automatically each time the instrument is switched on on the condition that the process value is lower with Func HEAt than SP SP 2 or higher with Func CooL than SP SP 2 2 if FASTautotuning is desired automatically the next time the instrument is switched on on the condition that the process value is lower with Func HEAt than SP SP 2 or higher with Func CooL than SP SP 2 and once the tuning is finished the par Auto is automatically swapped to the OFF state 3 if manual FAST auto tuning is desired by selecting par tunE in the main menu or by correctly programming key U as USrb tunE The Autotuning will start at the condition that the process value is lower wi
73. attivo tramite il parametro SPAt e tramite il tasto U SP1 4 La seguente combinazione di chiusura dei contatti con nessi ai due ingressi digitali permette l attivazione di uno dei 4 set point memorizzati DIG IN1 DIG IN2 SET POINT off off SP1 on off SP2 off on SP3 on on SP4 Quando la funzione attivata disabilita la selezione del set attivo tramite il parametro SPAt e tramite il tasto U HE Co La chiusura del contatto connesso all ingresso digitale 1 seleziona come attivo il set point SP2 con modalit di regolazione CooL mentre l apertura del contatto seleziona come attivo il set point SP1 con modalit di regolazione HEAt La funzione attua bile solo con nSP 2 inoltre quando attivata disabilita la sele zione del set attivo tramite il parametro SPAt e tramite il tasto U 4 15 INTERFACCIA SERIALE RS 485 Lo strumento pu essere dotato di una interfaccia di comunicazione seriale del tipo RS 485 attraverso la quale possibile collegarlo ad un rete in cui sono inseriti altri strumenti regolatori o PLC e facente capo tipicamente ad un personal computer utilizzato come supervisore dell impianto Attraverso il personal computer quindi possibile acquisire tutti i dati di funzionamento e programmare tutti i parametri di configurazione dello strumento Il protocollo software adottato nel TLK 31 D del tipo MODBUS RTU largamente utilizzato in
74. auben Werte Autotuning wiederholen nachdem die Fehlerursache gefunden wurde noAt Autotuning nicht innerhalb Das Autotuning von 12 Stunden wiederholen abgeschlossen nachdem der F hler und der Verbraucher auf ihre Funktionst chtigkeit berpr ft wurden LbA Unterbrechung des Das Ger t wieder in Einstellrings Loop break den Regelzustand alarm versetzen rEG nachdem der F hler 25 C NTC 103AT 2 10KQ 25 C Ausgang Ausg nge bis zu 4 Ausg nge 2 Relaisausg nge SPDT und 2 SPST NO 8 A AC1 3 A AC3 250 VAC oder Spannungsausg nge zur SSR Steuerung 10mA 10VDC Ausgang Hilfsversorgung max 12 VDC 20 mA Elektrische Lebensdauer der Relaisausg nge 100000 Schaltspiele Installationskategorie Il Ma Kategorie Schutzart gegen Stromschl ge Frontseitig Klasse Il Isolierungen Verst rkung zwischen den Niederspannungsbauteilen Relaisausgange und Frontseite Verst rkung zwischen den Niederspannungsbauteilen Relaisausg nge und den Unterspannungsbauteilen Versorgung Eingang Statikausg nge Keine Isolierung zwischen Versorgung und Eingang Keine Isolierung zwischen Eingang und Statikausgangen 50 WV Isolierung zwischen RS485 und Unterspannungsbauteilen 7 2 MECHANISCHE MERKMALE Geh use UL 94 VO Kunststoff Einbauma e 78 x 35 mm Einbautiefe 75 5 mm Gewicht ca 150 g Einbau Schalttafel in 29 x 71 mm Anschluss Schraubklemmleiste 2 5 mm Front Schutzart IP 65
75. chen Augenblick unterbrochen Anmerkung dies gilt nicht f r den Lesevorgang auf dem Display die Anzeige kann sich mit einer mit dem Messfilter proportionalen Verz gerung stabilisieren Mit aktivierter Hold Funktion f hrt das Instrument die Regelung in Abh ngigkeit von dem gespeicherten Messwert durch Wird der Kontakt erneut ge ffnet setzt das Instrument die normale Messwerterfassung fort OFF Wenn der an den digitalen Eingang 1 angeschlossene Kontakt geschlossen wird w hrend sich das Instrument im Zustand rEG befindet wird das Instrument in den Zustand OFF umgeschaltet Bei erneutem ffnen des Kontakts kehrt das Instrument in den Status der automatischen Regelung rEG zur ck CHSP Durch wiederholtes ffnen und Schlie en des an den Digitaleingang 1 angeschlossenen Kontakts kann aus der Sequenz einer der 2 gespeicherten Sollwerte ausgew hlt werden SP1 2 Bei Schlie en des an den Digitaleingang 1 angeschlossenen Kontakts wird Sollwert SP2 als aktiv ausgew hlt w hrend das ffnen des Kontakts Sollwert SP1 als aktiv festlegt Die Funktion ist nur bei nSP 2 verf gbar und sperrt wenn sie aktiviert ist die Auswahl des aktiven Sollwerts ber den Parameter SPAt und die Taste U HE Co Bei Schlie en des an den Digitaleingang 1 angeschlossenen Kontakts wird Sollwert SP2 als aktiv ausgew hlt mit regelung CooL w hrend das ffnen des Kontakts Sollwert SP1 als aktiv festlegt mit regelung
76. crementa o decrementa in modo veloce e dopo due secondi nella stessa condizione la velocit aumenta ulteriormente per consentire il rapido raggiungimento del valore desiderato Una volta impostato il valore desiderato premendo il tasto P si esce dalla modalit rapida di impostazione oppure si passa alla visualizzazione delle soglie di allarme vedi par 2 3 L uscita dal modo di impostazione rapida dei Set avviene alla pressione del tasto P dopo la visualizzazione dell ultimo Set oppure automaticamente non agendo su alcun tasto per circa 15 secondi trascorsi i quali il display torner al normale modo di funzionamento 2 2 SELEZIONE DEGLI STATI DI REGOLAZIONE E PROGRAMMAZIONE DEI PARAMETRI Premendo il tasto P e mantenendolo premuto per circa 2 sec si accede al men di selezione principale Mediante i tasti UP o DOWN possibile quindi scorrere le selezioni OPEr permette di accedere al men dei parametri operativi ConF permette di accedere al men dei parametri di configurazione L accesso a questa modalit pu essere protetta con una password personalizzabile OFF permette di porre il regolatore nello stato di regolazione OFF rEG permette di porre il regolatore in stato di regolazione automatica tunE permette di attivare la funzione di Autotuning o Selftuning OPLO permette di porre il regolatore nello stato di regolazione manuale e quindi di impostare il valore di regolazi
77. d Oscillatory AUTOTUNING SELFTUNING and FUZZY OVERSHOOT CONTROL for regulating the PID Furthermore the instrument allows for 2 digital inputs and RS485 serial communication using MODBUS RTU communication protocol and a transmission speed up to 38 400 baud The process value is visualized on 4 red displays while the output status is indicated by 4 LED displays The instrument is equipped with a 3 LED programmable shift indexes The instrument provides for the storage of 2 Set Points and can have up to 4 outputs relay type or can drive solid state TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 1 relays type SSR Other important available functions are Loop Break Alarm function reaching of the Set Point at controlled speed ramp and dwell function Soft Start function protection compressor function for neutral zone control parameters protection on different levels 1 2 FRONT PANEL DESCRIPTION 1 Key P This is used to access the programming parameters and to confirm selection 2 Key DOWN This is used to decrease the values to be set and to select the parameters If the key is held down the user returns to the previous programming level until he exits the programming mode Outside the programming mode it permits visualisation of the current measured by the TAHB input 3 Key UP This is used to increase the values to be set and to select the parameters If the key
78. dE LHdE 67 tcr1 Zykluszeit Ausgang 0 1 130 0 20 0 47 Ab3 Betriebskonfiguration 0 31 0 1 rEg sec Alarm AL3 siehe Ab1 68 Prat Leistungsverh ltnis 0 01 99 99 1 00 48 AL3 Alarmgrenzwert AL3 AL3L AL3H 0 2 rEg 1 rEg 49 AL3L Unterer Alarmgrenzwert 1999 AL3H 1999 69 tcr2 Zykluszeit Ausgang 0 1 130 0 10 0 AL3 f r Bandwert 2 rEg sec Alarme oder Tiefster 70 rS Manueller Reset 100 0 100 0 0 0 alarmgrenzwert AL3 sollwert f r tiefstwert 71 SLor Geschwindigkeit der 0 00 99 99 InF alarm und h chstwert erste rampe InF alarm unit min 50 AL3H Oberer Alarmgrenzwert AL3L 9999 9999 72 dur t Duration time 0 00 99 59 InF AL3 f r Bandwert InF Alarme oder H chster hrs min alarmgrenzwert AL3 73 SLoF Geschwindigkeit der 0 00 99 99 InF sollwert f r tiefstwert zweiter rampe InF alarm und h chstwert unit min alarm 74 St P Soft Start Leistung 100 100 0 51 HAL3 Hysterese auf Alarm OFF 9999 1 75 SSt Soft Start Zeit OFF OFF AL3 0 1 7 59 52 AL3d Einschaltverz gerung OFF 9999 OFF InF Alarm AL3 sec hrs min 53 AL3i Alarmaktivierung AL3 no yES no Gruppe PAn Parameter der Benutzerschnittstelle bei Messfehler Par Beschreibung Bereich Def Note Gruppe LbA Parameter des Loop Break Alarms 76 USrb Funktion der Taste U noF tunE noF Par Descrizione Range Def Note noF keine Funktion OPLO Aac 54 OLbA Ausgang f r Al
79. den H chstwert nicht berschreitet Da das Ger t f r einen permanenten Anschluss in einer Einrichtung vorgesehen ist verf gt es weder ber Schalter noch ber interne Schutzvorrichtungen gegen berstrom Daher ist ein als Abschalteinrichtung markierter bipolarer Schalter Trennschalter vorzusehen der die Stromversorgung zum Ger t unterbricht Dieser Schalter muss so nah wie m glich am Ger t und an einer f r den Betreiber gut erreichbaren Stelle installiert werden Au erdem sind alle am Ger t angeschlossenen Kreisl ufe durch geeignete den vorhandenen Stromwerten entsprechende Vorrichtungen z B Sicherungen abzusichern Es sind Kabel zu verwenden die ber geeignete den Spannungen Temperaturen und Betriebsbedingungen entsprechende Isolierung verf gen und es muss darauf geachtet werden dass die Kabel der Eingangsf hler separat von den Stromkabeln und anderen Leistungskabeln verlegt werden um eine Induktion elektromagnetischer St rungen zu vermeiden Bei Verwendung von abgeschirmten Kabeln sind diese nur einseitig zu erden Zur Speisung des Ger tes wird die Verwendung des Transformators TCTR bzw eines Transformators mit entsprechenden Merkmalen empfohlen es sollte f r jedes Ger t ein Trafo verwendet werden da zwischen Speisung und Eingang keine Isolierung besteht Vor Anschluss der Ausg nge an die Verbraucher ist unbedingt sicherzustellen dass die eingestellten Parameter auch tats chlich den gew nschten Parame
80. den Tasten UP und DOWN die Zahlen f r das im Parameter PASS eingestellte Passwort ausw hlen und anschlie end die Taste P dr cken Wenn das eingegebene Passwort nicht korrekt ist kehrt das Ger t in den vorhergehenden Programmstatus zur ck Bei richtiger Passworteingabe erscheint eine Abk rzung mit die erste Parametergruppe ISP identifiziert wird anhand der Tasten UP und DOWN kann die zu ver ndernde Parametergruppe angew hlt werden Programmierart und Verlassen des Men s ConF entsprechen dem Men OPEr F r die Deaktivierung der Passwortfunktion in dem Parameter PASS die Option PASS OFF einstellen PARAMETER GROUPS PARAMETERS SET PARAMETER Previous Previous Increase A Group A Parameter A Value Ae Na Mec Next 2 fy Next WD 2sec exi ex ecrease y Group y Parameter y Value EXIT HINWEIS Bei Verlust des Passworts das Ger t von der Stromversorgung trennen die Taste P dr cken das Ger t wieder an die Stromversorgung anschlie en und anschlie end die Taste ca 5 Sekunden gedr ckt halten Auf diese Weise haben Sie auf alle Parameter im Men ConF Zugriff und in dem Parameter PASS kann das Passwort berpr ft bzw ge ndert werden 2 3 PROGRAMMIEREBENEN DER PARAMETER Das Men OPEr enth lt normalerweise die Einstellparameter der Sollwerte allerdings kann auf dieser Ebene bestimmt werden welche Param
81. der zum normalen Regelbetrieb OPLO und umgekehrt bergegangen werden Aac Wird die Taste mindestens 1 Sekunde lang gedr ckt kann ein gespeicherter Alarm zur ckgesetzt werden siehe Abschnitt 4 11 1 ASi Wird die Taste mindestens 1 Sekunde lang gedr ckt kann ein aktiver Alarm quittiert werden siehe Abschnitt 4 11 1 CHSP Wird die Taste mindestens 1 Sekunde lang gedr ckt kann nacheinander einer der 4 gespeicherten Sollwerte angew hlt werden OFF Wird die Taste mindestens 1 Sekunde lang gedr ckt kann vom automatischen Regelmodus rEG zum deaktivierten Regelmodus OFF und umgekehrt bergegangen werden 4 14 DIGITALER EINGANGE Das Ger t kann mit zwei Digitaleingange ausgestattet sein dessen Funktion ber den in der Gruppe InP befindlichen Parameter diF konfigurierbar ist Folgende Einstellungen sind f r diesen Parameter m glich noF Dem Eingange ist keine Funktion zugeordnet Aac Durch Schlie en des Kontakts der an den Digitaleingang 1 angeschlossen ist kann ein gespeicherter Alarm zur ckgestellt werden siehe Abschnitt 4 11 ASi Durch Schlie en des Kontakts der an den Digitaleingang 1 angeschlossen ist kann ein aktiver Alarm quittiert werden siehe Abschnitt 4 11 TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 10 Hold Durch Schlie en des Kontakts der an den Digitaleingang 1 angeschlossen ist wird die Erfassung des Messwertes im glei
82. e identifying the first parameter of the selected group will be visualised by pushing the P key Again using the UP and DOWN keys it is possible to select the desired parameter and if the key P is pressed the display will alternatively show the parameter s code and its programming value which can be modified by using the UP or DOWN keys Once the desired value has been programmed push key P once more the new value will be memorised and the display will show only the code of the selected parameter TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 2 By using the UP or DOWN keys it is then possible to select a new parameter if present and modify it as described above To select another group of parameters keep the UP or DOWN key pressed for approx 2 sec afterwards the display will return to visualise the code of the group of parameters Release the key and by using the UP and DOWN keys it will be possible to select a new group if present To exit the programming mode no key should be pressed for approx 20 seconds or keep the UP or DOWN pressed until exit from the programming mode is obtained To bring up the ConF menu a personalized PASSWORD can be made necessary through the PASS parameter If this protection is required set the password number desired in the PASS parameter and exi
83. e alarm Out1 Out2 OFF CHSP Cambio Set att LbA is addressed Out3 Out4 OFF messa in OFF OFF della regolazione 55 LbAt Time necessary to acti OFF 9999 OFF 77 diSP Variable visualized on Pr1 Pr2 P1 2 vate alarm LbA sec the display P1 2 Pou Group rEG parameters relative to the control Pr1 Pr1 Value SP F SP 0 Par Description Range Def Note Pr2 Pr2 Value AL1 AL2 56 Cont Control type Pid On FA Pid P1 2 Pri Pr2 Value AL3 Pid PID On FS nr Pou Control Power On FA ON OFF asym SP F Active Set Value SP o Operative Set value AL1 AL 1 threshold AL2 AL2 threshold AL3 AL3 threshold On FS ON OFF sym nr Neutral Zone ON OFF 57 Func Functioning mode HEAt CooL HEAt output 1 rEG 58 PrrG Control process meas Pr1 Pr2 Pri urement reference P1 2 P1 L 78 AdE Shift value for the shift OFF 9999 2 index functioning 79 Edit Fast progr Active Set SE AE SAE and alarms SAE SANE SE Active Set can be modified while the alarm thresholds can 59 HSEt Hysteresis of ON OFF 0 9999 1 control or end Soft Start cycle threshold 60 CPdt Compressor Protection OFF 9999 0 time for 2 rEG sec 3 61 Auto Autotuning enable 41 3 1 21 1 0 pa rar ssa OFF Not active vo be modified while the 1 Start each power on 1 2 3 4 alana thieaholds can 2 Start at first power be
84. e automatica rEG dopo aver controllato il corretto funzionamento della sonda e dell attuatore Per escludere l allarme di Loop Break sufficiente programmare OLbA OFF 4 13 FUNZIONAMENTO DEL TASTO U Oltre alla normale funzione di visualizzazione delle variabili Pr1 Pr2 e P1 2 il tasto U pu essere programmato per eseguire altre funzioni mediante il parametro USrb contenuto nel gruppo IPAn Il parametro pu essere programmato come noF Il tasto non esegue nessuna funzione tunE Premendo il tasto per almeno 1 sec possibile attivare disattivare l Autotuning o il Selftuning se abilitati con i relativi parametri OPLO Premendo il tasto per almeno 1 sec possibile passare dal modo di regolazione automatica rEG a quello manuale OPLO e viceversa Aac Premendo il tasto per almeno 1 sec possibile resettare un allarme memorizzato vedi par 4 10 1 ASi Premendo il tasto per almeno 1 sec possibile tacitare un allarme attivo vedi par 4 10 1 CHSP Premendo il tasto per almeno 1 sec possibile selezionare a rotazione uno dei 4 Set Point memorizzati OFF Premendo il tasto per almeno 1 sec possibile passare dal modo di regolazione automatica rEG a quello di regolazione disattivata OFF e viceversa 4 14 INGRESSI DIGITALI Lo strumento pu essere dotato di due ingressi digitali il cui funzionamento configurabile mediante il parametro diF contenuto ne
85. eaktivieren ist im Men SEL ein beliebiger Regelzustand anzuw hlen rEG OPLO oder OFF Wird das Ger t w hrend eines Autotuning Zyklus bzw bei aktivierter Selftuning Funktion abgeschaltet sind diese Funktionen bei Wiedereinschaltung des Ger tes noch aktiv 4 9 ERREICHEN DES SOLLWERTES BEI VORGEGEBENER GESCHWINDIGKEIT UND AUTOMATISCHE UMSCHALTUNG ZWISCHEN ZWEI SOLLWERTEN RAMPEN UND ERHALTUNGSZEIT Alle Parameter der Rampenfunktionen befinden sich in der Gruppe EG Es kann eine Einstellung vorgenommen werden damit der Sollwert innerhalb einer vorgegebenen Zeit erreicht wird wobei diese h her ist als die Zeit die das System normalerweise ben tigen w rde Dies kann in Prozessen W rmebehandlungen chemische Behandlungen usw n tzlich sein in denen der Sollwert schrittweise und innerhalb einer vorgegebenen Zeit erreicht werden muss Au erdem kann daf r gesorgt werden dass das Ger t sobald der erste Sollwert SP1 erreicht wurde automatisch nach einer programmierten Zeit auf den zweiten Sollwert SP2 umschaltet wodurch ein einfacher automatischer W rmezyklus erzeugt wird Diese Funktionen sind f r alle programmierbaren Regelarten verf gbar Dem Betrieb liegen die folgenden Parameter zugrunde SLor Neigung der erste rampe angegeben in Einheit Minute SLoF Neigung der zweiter rampe angegeben in Einheit Minute dur t Erhaltungszeit des Sollwertes SP1 bevor automatisch auf SP2 umgescha
86. easured at 20 but that at 200 it visualises a value lower than 10 190 Therefore M1 20 D1 20 M2 200 D2 190 rot 190 20 200 20 0 944 OFSt 190 0 944 x 200 1 2 Example 2 It is desired that the instrument visualises 10 whilst the value actually measured is 0 but at 500 it visualises a 50 higher value 550 Therefore M1 0 D1 10 M2 500 D2 550 rot 550 10 500 0 1 08 OFSt 550 1 08 x 500 10 By using par FiL it is possible to program time constant of the software filter for the input value measured in order to reduce noise sensitivity increasing the time of reading In case of measurement error the instrument supplies the power as programmed on par OPE This power will be calculated according to cycle time programmed for the PID controller while for the ON OFF controllers the cycle time is automatically considered to be equal to 20 sec e g In the event of probe error with ON OFF control and OPE 50 the control output will be activated for 10 sec then it will be deactivated for 10 sec and so on until the measurement error remains By using par InE it is also possible to decide the conditions of the input error allowing the instrument to give the power programmed on par OPE as output The possibilities of par InE are Or the condition occurs in case of over range or probe breakage Ur
87. egato all uscita configurata come 2 rEG Il modo di regolazione di tipo PID a doppia azione agisce pertanto sulle uscite 1 rEG e 2 rEG in funzione del Set point SP attivo e del risultato dell algoritmo di controllo PID a due gradi di libert dello strumento Per ottenere una buona stabilit della variabile in caso di processi veloci i tempi di ciclo tcr1 e tcr2 devono avere un valore basso con un intervento molto frequente delle uscite di regolazione In questo caso si raccomanda l uso di un rel statico SSR per il comando degli attuatori L algoritmo di regolazione PID a doppia azione dello strumento prevede l impostazione dei seguenti parametri Pb Banda Proporzionale ter1 Tempo di ciclo dell uscita 1 rEG ter2 Tempo di ciclo dell uscita 2 rEG Int Tempo Integrale rS Reset manuale solo se Int 0 dEr Tempo derivativo FuOC Fuzzy Overshoot Control Prat Power Ratio o rapporto tra potenza dell elemento comandato dall uscita 2 rEG e potenza dell elemento comandato dall uscita 1 rEG 4 8 FUNZIONI DI AUTOTUNING E SELFTUNING Tutti i parametri riguardanti le funzioni di AUTOTUNING e SELFTU NING sono contenuti nel gruppo rEG La funzione di AUTOTUNING e la funzione di SELTUNING permet tono la sintonizzazione automatica del regolatore PID La funzione di AUTOTUNING prevede il calcolo dei parametri PID attraverso un ciclo di sintonizzazione di tipo FAST oppure di ti
88. ello strumento e quando viene cambiato il valore di set point attivo Se invece si desidera realizzare un ciclo automatico dall accensio ne dello strumento occorre programmare il par nSP 2 imposta re i due valori SP1 e SP2 e naturalmente programmare i par SLor dur t e SLoF con i valori desiderati In questo caso al termine del ciclo tutte le rampe non saranno pi attive SV Unit SP1 change SP1 Value time min SV U nit SP1 AUTO change Set time min Gli esempi sono con partenza da valori inferiori a SP1 e con suc cessiva diminuzione del Set Point Nota In caso di regolatore PID se si desidera effettuare l autotu ning ed attiva una rampa questa non viene eseguita Si racco manda pertanto di eseguire l Autotuning senza attivare alcuna ram pa e quindi una volta eseguita la sintonizzazione disabilitare Au totuning Auto 0 programmare le rampe desiderate e se si de sidera la sintonizzazione automatica abilitare la funzione di Selftuning 4 10 FUNZIONE DI SOFT START Tutti i parametri riguardanti il funzionamento del Soft Start sono contenuti nel gruppo IrEG La funzione di Soft Start attuabile solo con regolazione PID e consente di limitare la potenza di regolazione all accensione dello strumento per un tempo prefissato Ci risulta utile quando l attuatore comandato dallo strumento si potrebbe danneggiare a causa di u
89. en des Ger ts immer automatisch ein OSZILLIERENDES Autotuning durchgef hrt werden soll 2 wenn beim nachfolgenden Einschalten des Ger ts immer ein OSZILLIERENDES Autotuning durchgef hrt und nach Abschluss der Abstimmung automatisch der Wert Auto OFF eingestellt werden soll 3 wenn das OSZILLIERENDE Autotuning manuell mit der Taste U eingestellt werden soll 4 wenn das OSZILLIERENDE Autotuning automatisch bei jeder Ver nderung des Set Points f r die Regelung oder nach Abschluss des programmierten Soft Start Zyklus eingeschaltet werden soll HINWEIS Das Autotuning Fast ist besonders schnell und hat keine Auswirkung auf die Regelung weil es die Parameter f r den Regler w hrend des Erreichens des Set Points kalkuliert F r die korrekte Ausf hrung des Autotunings Fast muss aber bei Start des Vorgangs eine geringf gige Differenz zwischen der Prozessvariablen und dem Set Point bestehen Deshalb schaltet das Ger t das Autotuning Fast nur dann ein wenn F r Auto 1 oder 2 gilt Der Prozesswert ist kleiner f r Func HEAt als SP SP 2 oder gr er f r Func CooL als SP SP 2 F r Auto 3 oder 4 gilt Der Prozesswert ist kleiner f r Func HEAt als SP SP 5 oder gr er f r Func CooL als SP SP 5 J Es wird empfohlen kein Autotuning FAST auszuf hren wenn der Set Point kurz vor dem ersten Ablesen steht oder wenn die gemessene Variable ungleichm
90. er wird bestimmt in welchen Zustand sich der Alarm bei einem Ger temessfehler zu versetzen hat yES Alarm aktiv no Alarm nicht aktiv 4 12 FUNKTION DES LOOP BREAK ALARMS Alle Parameter des Loop Break Alarms befinden sich in der Gruppe ILbA Bei allen Ger ten ist ein Loop Break Alarm verf gbar der den Regler sofort abschaltet wenn aus irgendeinem Grund Kurzschluss eines Thermoelements Umschaltung eines Thermoelements Lastausfall der Einstellring unterbrochen wird Zur Konfiguration des Ausgangs dem der Loop Break Alarm zugewiesen werden soll muss jedoch zuerst bestimmt werden welchem Ausgang der Alarm entsprechen soll Dazu muss in der Parametergruppe Out der Parameter des Ausgangs der verwendet werden soll O1F 02F O3F O4F unter Eingabe des entsprechenden Parameters des gew nschten Ausgangs konfiguriert werden ALno wenn der Alarmausgang bei aktivem Alarm aktiviert werden soll und bei nicht aktivem Alarm deaktiviert sein soll ALnc wenn der Alarmausgang bei deaktiviertem Alarm aktiviert werden soll und bei aktivem Alarm deaktiviert sein soll ALni wenn es das gleiche Funktionieren von ALnc w nscht aber mit Funktionieren des verneinten Vorder led zeigt der Vorder led des Ger tes den Staat des Ausganges in dieser Fall an Die Gruppe ILbA ffnen und im Parameter OLbA eingeben f r welchen Ausgang das Alarmsignal bestimmt werden soll Der Loop Break Alarm
91. erese bzw SP bei asymmetrischer Hysterese erreicht hat und aktiviert ihn wieder wenn der Wert unter SP HSEI sinkt Umgekehrt d h bei direktem Wirkungssinn oder K hlen Func CooL deaktiviert der Regler den Ausgang wenn der Istwert den Wert SP HSEt bei symmetrischer Hysterese bzw SP bei asymmetrischer Hysterese erreicht hat und aktiviert ihn wieder wenn er den Wert SP HSEt berschreitet _ DLL ZZZ DD CooL On FS HEAt On FS 4 5 EIN AUS REGELUNG BEI NEUTRALER ZONE 1 rEG 2 rEG S mtliche Parameter der EIN AUS Regelung bei neutraler Zone befinden sich in der Gruppe IrEG Dieser Betrieb kann aktiviert werden wenn 2 Ausg nge als 1 rEG und 2 rEG konfiguriert wurden die Funktion wird durch Programmieren des Parameters Cont nr bestimmt Die Regelart mit neutraler Zone wird zur Steuerung von Anlagen verwendet die ber ein Element verf gen das einen positiven Anstieg erzeugt z B ein Heizen Anfeuchten usw und ber ein Element das einen negativen Anstieg erzeugt z B K hlen Entfeuchten usw Der Regelbetrieb wirkt auf die Ausg nge die nach der programmierten Messung dem aktiven Sollwert SP und der Hysterese HSEt konfiguriert wurden Dabei verh lt sich der Regler wie folgt Er schaltet die Ausg nge ab wenn der Istwert den Sollwert erreicht und aktiviert den Ausgang 1 rEG wenn der Istwert niedriger ist als SP HSEt bzw er schaltet den Ausgang 2 rE
92. erte hier k nnen jedoch auch alle gew nschten Parameter stehen siehe Abschnitt 2 3 ConF Men der Konfigurationsparameter Dieses enth lt alle Betriebsparameter und Konfigurationsparameter Alarmkonfiguration Regelung Eingang usw 4 EG rEb gt 1 PreBe ur AI PI HBPErF fp AV Conf pl Q n n yA HHHP AV AUTOTUNING ry a t SELFTUNING tunk A HP ga A Vv y y Se OPLO OPLO PHOPLO Das Men OPEr wird durch Anw hlen des entsprechenden Menipunktes OPEr und Dr cken der Taste P ge ffnet TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 2 Nun erscheint auf der Anzeige eine Abk rzung mit der die erste Parametergruppe ISP identifiziert wird anhand der Tasten UP und DOWN kann die zu ver ndernde Parametergruppe angezeigt werden Wurde die gew nschte Parametergruppe angew hlt muss die Eingabe durch Dr cken der Taste P best tigt werden um die Abk rzung des ersten Parameters anzuzeigen Der gew nschte Parameter wird anhand der Tasten UP und DOWN angezeigt und durch Dr cken der Taste P best tigt auf der Anzeige erscheint abwechselnd die Parameterabk rzung und der ein
93. et point attivo che le soglie di allarme sono editabili SANE Sia il Set point attivo che le soglie di allarme non sono editabili 2 4 STATI DI REGOLAZIONE Il controllore pu assumere 3 diversi stati regolazione automatica rEG regolazione disattivata OFF e regolazione manuale OPLO Lo strumento pu passare da uno stato di regolazione all altro Da tastiera selezionando lo stato desiderato nel men di selezione principale Da tastiera tramite il tasto U programmando opportunamente il par USrb USrb tunE USrb OPLO USrb OFF si pu passare dallo stato rEG allo stato programmato al parametro e viceversa Mediante l ingresso digitale 1 opportunamente programmato attraverso il par diF diF OFF si pu passare dallo stato rEG allo stato OFF Automaticamente lo strumento si porta nello stato rEG al termine dell esecuzione dell autotuning All accensione lo strumento si porta automaticamente nello stato che aveva al momento dello spegnimento REGOLAZIONE AUTOMATICA rEG Lo stato di regolazione automatica il normale stato di funzionamento del controllore Durante la regolazione automatica possibile visualizzare la potenza di regolazione sul display premendo il tasto UP I valori visualizzabili per la potenza variano da H100 100 di potenza in uscita con azione inversa a C100 100 di potenza in uscita con azione diretta REGOLAZIONE D
94. eter angezeigt oder ausgeblendet werden sollen Hierzu ist wie folgt beschrieben vorzugehen Das Men ConF ffnen und den Parameter der im Men OPEr programmierbar oder nicht programmierbar sein soll anw hlen Wurde der Parameter angew hlt und ist die Led SET aus so ist der Parameter lediglich im Men ConF programmierbar leuchtet die Led hingegen so kann der Parameter auch im Men OPEr programmiert werden Zur nderung der Parameteranzeige ist die Taste U zu dr cken Die Led SET signalisiert den Anzeigezustand des Parameters leuchtet Men OPEr und ConF aus nur Men ConF Auf der unter Abschnitt 2 1 beschriebenen Schnelleinstellebene der Sollwerte erscheinen der aktive Sollwert und die Alarmgrenzwerte nur dann wenn die entsprechenden Parameter als operative Parameter konfiguriert wurden d h sie stehen im Men OPEr Eine nderung dieser Sollwerte nach der unter Abschnitt 2 1 beschriebenen Vorgehensweise unterliegt hingegen der Programmierung unter Abschnitt Edit in der Gruppe PAn Dieser Parameter kann wie folgt beschrieben ver ndert werden SE Der aktive Sollwert ist editierbar w hrend die Alarmgrenzwerte nicht editierbar sind AE Der aktive Sollwert ist nicht editierbar w hrend die Alarmgrenzwerte editierbar sind SAE Sowohl der aktive Sollwert als auch die Alarmgrenzwerte sind editierbar SAnE Weder der aktive Sollwert noch die
95. f r die ausgew hlte Betriebsart unwichtig sind und folglich automatisch ausgeblendet werden Gruppe SP Parameter des Sollwertes Par Beschreibung Bereich Def Note 1 nSP Anzahl der 1 4 1 programmierbaren Sollwerte 2 SPAt Aktiver Sollwert 1 nSP 1 3 SP1 Sollwert 1 SPLL SPHL 0 4 SP2 Sollwert 2 SPLL SPHL 0 TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 11 25 PrA1 Prozesswert f r Alarm AL1 Pr1 Pr2 P1 2 P1 L Pr1 26 AL1t Alarmart AL1 LoAb Tiefstwertalarm HiAb H chstwertalarm LHAb Bandwert alarm LodE Tiefstwertalarm HidE H chstwertalarm LHdE Bandwert alarm Abs Abs Abs Rel Rel Rel LoAb HiAb LHAb LodE HidE LHdE LoAb 27 Ab1 Betriebskonfiguration Alarm AL1 1 Einsch nicht akt 2 Verz gerter 4 Gespeicher 8 Quitterbarer 16 nicht akt bei wechsel des Sollwert Rel Al 28 AL1 Alarmgrenzwert AL1 AL1L AL1H 29 AL1L Unterer Alarmgrenzwert AL1 f r Bandwert Alarme oder Tiefster alarmgrenzwert AL1 sollwert f r tiefstwert alarm und h chstwert alarm 1999 AL1H 1999 30 AL1H Oberer Alarmgrenzwert AL1 f r Bandwert Alarme oder H chster alarmgrenzwert AL1 sollwert f r tiefstwert alarm und h chstwert alarm AL
96. f the measure in that instant P A not the reading on the display therefore the indication could settle with a proportional delay to the filter of measure With the function hold the instrument operate the control in base to the memorized measure Reopening the contact the instrument come back to the normal acquisition of the measure OFF Closing the contact connected to the digital input 1 it is possible to select the OFF control OFF CHSP Closing and opening the contact connected to the digital input 1 it is possible to select one of the 4 pre programmed Set Points on rotation SP1 2 Closing the contact connected to the digital input 1 it is possible to select as active the set point SP2 Reopening the contact is select as active the set point SP1 This function is possible only when nSP 2 and when is selected it disables the selection of the active set through the parameter SPAt and through the key U HE Co Closing the contact connected to the digital input 1 it is possible to select as active the set point SP2 in CooL mode Reo pening the contact is select as active the set point SP1 in HEAt mode This function is possible only when nSP 2 4 15 RS 485 SERIAL INTERFACE The instrument can be equipped with a RS 485 serial communication interface by means of which it is possible to connect the regulator with a net to which other instruments regulators of PLC are connected all depending
97. gestellte Wert der wiederum durch Dr cken der Tasten UP oder DOWN ver ndert werden kann Wurde der gew nschte Wert eingestellt ist erneut die Taste P zu dr cken Der neue Wert wird nun gespeichert und auf der Anzeige erscheint lediglich die Abk rzung des angew hlten Parameters Anhand der Tasten UP oder DOWN kann nun ein weiterer Parameter sofern vorhanden angew hlt und wie beschrieben ver ndert werden Soll eine neue Parametergruppe ge ffnet werden ist die Taste UP oder die Taste DOWN ca 2 Sekunden lang gedr ckt zu halten daraufhin erscheint auf der Anzeige die Abk rzung der Programmgruppe Die gedr ckte Taste loslassen anhand der Tasten UP und DOWN kann nun eine neue Parametergruppe sofern vorhanden angew hlt werden Der Programmiermodus wird verlassen wenn ca 20 Sekunden lang keine Taste mehr gedr ckt wird bzw indem die Taste UP oder DOWN solange gedr ckt gehalten wird bis der Programmiermodus verlassen wurde F r den Zugriff auf das Men ConF wird eventuell ein pers nliches PASSWORT ber den Parameter PASS angefordert F r die Aktivierung dieser Schutzfunktion f r den Parameter PASS die gew nschte Zahlenkombination eingeben und anschlie end die Funktion f r die Programmierung der Parameter verlassen Wenn die Schutzvorrichtung aktiviert ist muss f r den Zugriff auf die Parameter im Men ConF das programmierte Passwort eingegeben werden Bei der Anfrage des Passworts mit
98. h to which output the alarm has to correspond to First of all it s necessary to configure in the parameters group lOut the parameters relative to the outputs required as alarm O1F O2F 03F O4F programming the parameter relative to the desired output as follows ALno if the alarm output has to be ON when the alarm is active while it s OFF when the alarm is not active ALnc if the alarm output has to be ON when the alarm is not active while it s OFF when the alarm is active ALni if the alarm output has to be ON when the alarm is not active while it is OFF when the alarm is active but with reverse led indication led ON alarm OFF Note In all the examples that follow is made reference to the alarm AL1 Naturally the operation of the other alarms results analogous Have now access at the group AL1 and program on par QAL1 to which output the alarm signal has to be sent The alarm functioning is instead defined by parameters PrA1 1 ALARM PROCESS MEASUREMENT AL1t ALARM TYPE Ab1 ALARM CONFIGURATION AL1 ALARM THRESHOLD AL1L LOW ALARM THRESHOLD for band alarm OR MINIMUM SET OF AL1 ALARM THRESHOLD for low or high alarm AL1H HIGH ALARM THRESHOLD for band alarm OR MAXIMUM SET OF AL1 ALARM THRESHOLD for low or high alarm HAL1 ALARM HYSTERESIS AL1d ALARM ACTIVATION DELAY in sec AL1i ALARM BEHAVIOUR IN
99. he next time it is switched on 4 9 REACHING OF THE SET POINT AT CONTROLLED SPEED AND AUTOMATIC SWITCHING BETWEEN TWO SET POINTS RAMPS AND DWELL TIME All the parameters referring to the ramps functioning are contained in the group IrEG It is possible to reach the set point in a predetermined time in any case longer than the time the plant would naturally need This could be useful in those processes heating or chemical treatments etc where the set point has to be reached gradually in a predetermined time Once the instrument has reached the first Set Point SP1 it is pos sible to have automatic switching to the second Set Point SP2 af ter a set time thus obtaining a simple automatic process cycle These functions are available for all the programmable controls PID single and double action ON OFF and Neutral Zone ON OFF The function is determined by the following parameters SLor Gradient of first ramp expressed in unit minute SLoF Gradient of second ramp expressed in unit minute dur t Dwell time of Set Point SP1 before automatic switching to Set Point SP2 expressed in hrs and min The functions are deactivated when the relative parameters are InF If is desired only one ramp ex to reach SP1 it is enough to program on the par SLor the desired value The ramp SLor it will always active at power on and when the Active Set Point value is changed PV Unit SP1
100. here the relative parameters O1F 02F O3F O4F depending on the number of outputs available on the instrument are located The outputs can be set for the following functions Main control output 1 rEG Secondary control output 2 rEG Alarm output normally open ALno Alarm output normally closed ALnc Alarm output normally closed with led reverse indication ALni Output deactivated OFF The coupling outputs number outputs number alarms can be made in the group referring to the alarm to the alarm AL1 JAL2 o IAL3 4 3 REGULATOR WITH ABSOLUTE OR DIFFERENTIAL TEMPERATURE Through the PrrG parameter it is possible to set the process variable used by the regulator to operate In fact the regulator can operate considering the process variable as the value measured at input 1 Pr1 the value measured at input 2 Pr2 the difference between the two inputs Pr1 Pr2 P1 2 or can consider the difference between the two inputs Pr1 Pr2 but with a maximum limit and a minimum limit for the Pr2 measurement Pr2 P1 L The PrrG choices P1 2 or P1 L make the regulator operate as a differential regulator Temp SP1 HSEt Example of differential ON OFF regulation On FA with Func CooL Attention The regulator is already programmed in production to carry out differential regulation and display the temperature difference Pr1 Pr2 In these cases
101. hiesta del regolatore La protezione del tipo con ritardo dopo lo spegnimento La protezione consiste nell impedire che si verifichi un attivazione dell uscita durante il tempo impostato al parametro CPdt espresso in sec e conteggiato a partire dall ultimo spegnimento dell uscita e quindi che l eventuale attivazione si verifichi solo allo scadere del tempo CPdt Se durante la fase di ritardo attuazione per inibizione della funzione protezione compressore la richiesta del regolatore dovesse venire a mancare naturalmente viene annullata la prevista attuazione dell uscita La funzione risulta disattivata programmando CPdt OFF Durante la fase di ritardo di attuazione uscita per inibizione della funzione di protezione compressore il led relativo all uscita 2 rEG lampeggiante 4 6 REGOLATORE PID A SINGOLA AZIONE 1 rEG Tutti i parametri riguardanti la regolazione PID sono contenuti nel gruppo rEG Il modo di regolazione di tipo PID a Singola Azione attuabile impostando il parametro Cont Pid ed agisce sull uscita 1 rEG in funzione del Set point SP attivo del modo di funzionamento FunC e del risultato dell algoritmo di controllo PID a due gradi di libert dello strumento PV SP tcri teri teri tcri teri teri tert Per ottenere una buona stabilit della variabile in caso di processi veloci il tempo di ciclo tcr1 deve avere un valore basso con un intervento molto freque
102. i siano quelli desiderati e che l applicazione funzioni correttamente prima di collegare le uscite agli attuatori onde evitare anomalie nell impianto che possano causare danni a persone cose o animali 3 4 SCHEMA ELETTRICO DI COLLEGAMENTO RELAY 8A AC1 3A AC3 250VAC SSR 10mA 10VDC wh ar OF a Ele oho Ewe ho Fre ho TLK31 D OUT4 OUT3 OUT2 OUT1 SUPPLY 4 FUNZIONAMENTO 4 1 MISURA E VISUALIZZAZIONE Tutti i parametri riguardanti la misura sono contenuti nel gruppo np Mediante il par SEnS possibile selezionare la tipologia di son de che si desidera utilizzare e che pu essere termistori PTC KTY81 121 Ptc o NTC 103AT 2 ntc Al cambio di questo parametro si raccomanda di spegnere e riaccendere lo strumento per ottenere una misura corretta Una volta selezionato il tipo di sonde utilizzate mediante il parame tro Unit possibile selezionare lunit di misura della temperatu ra C o F e mediante il parametro dP la risoluzione di misura desiderata 0 1 1 0 1 Se la sonda Pr2 non viene utilizzata impostare il par Pr 2 no in modo da evitare l indicazione dell errore quando la sonda non connessa Lo strumento consente la calibrazione delle misure che pu essere utilizzata per una ritaratura dello strumento secondo le necessit dell applicazione mediante i par OFS1 OFS2 e rot Impostando il par rot 1 000 al par OFS 1
103. ia superiore alla corrente massima consentita Lo strumento essendo previsto per collegamento permanente entro un apparecchiatura non dotato n di interruttore n di dispositivi interni di protezione da sovracorrenti Si raccomanda pertanto di prevedere l installazione di un interruttore sezionatore di tipo bipolare marcato come dispositivo di disconnessione che interrompa l alimentazione dell apparecchio Tale interruttore deve essere posto il pi possibile vicino allo strumento e in luogo facilmente accessibile dall utilizzatore Inoltre si raccomanda di proteggere adeguatamente tutti i circuiti connessi allo strumento con dispositivi es fusibili adeguati alle correnti circolanti Si raccomanda di utilizzare cavi con isolamento appropriato alle tensioni alle temperature e alle condizioni di esercizio e di fare in modo che i cavi relativi ai sensori di ingresso siano tenuti lontani dai cavi di alimentazione e da altri cavi di potenza al fine di evitare l induzione di disturbi elettromagnetici Se alcuni cavi utilizzati per il cablaggio sono schermati si raccomanda di collegarli a terra da un solo lato Per l alimentazione dello strumento si raccomanda luso dell apposito trasformatore TCTR o di trasformatore con caratteristiche equivalenti e si consiglia di utilizzare un trasformatore per ogni apparecchio in quanto non vi isolamento tra alimentazione ed ingresso Infine si raccomanda di controllare che i parametri impostat
104. iderato e uscire dalla programmazione parametri Quando la protezione attiva per poter aver accesso ai parametri del menu ConF occorre impostare la password programmata Alla richiesta della password impostare attraverso i tasti UP e DOWN il numero programmato al par PASS e premere quindi il tasto P Se si imposta una password errata lo strumento ritorna nello stato di regolazione in cui si trovava precedentemente Se la password corretta il display visualizzer il codice che identifica il primo gruppo di parametri ISP e con i tasti UP e DOWN sar possibile selezionare il gruppo di parametri che si intende editare Le modalit di programmazione e di uscita dalla programmazione del men ConF sono le stesse descritte per il men OPEr La protezione mediante password disabilitata impostando il par PASS OFF PARAMETER GROUPS PARAMETERS SET PARAMETER Previous Previous Increase A Group A Parameter A Value apt SP av mit Li N Next I Next Decrease 2sec Vv Group VI Parameter y Value EXIT NOTA In caso di smarrimento della password togliere alimentazio ne allo strumento premere il tasto P e ridare alimentazione allo strumento mantenendo premuto il tasto per circa 5 sec Si avr cos accesso a tutti i parametri del menu ConF e sar possibile pertanto verificare e modificare il parametro PASS 2 3 LIVELLI DI
105. igitaleingange durch den Parameter diF diF CHSP SP1 2 HE Co Automatisch zwischen SP1 und SP2 wenn eine Erhaltungszeit dur t siehe Abschnitt 4 9 Die Sollwerte SP1 SP2 werden nach der H chstzahl der im Parameter nSP eingestellten Sollwerte angezeigt und nach einem Wert zwischen dem im Parameter SPLL und dem im Parameter SPHL eingestellten Wert verandert SPLL ist der im Parameter programmierte Eingang Hinweis In den folgenden Beispielen steht f r den Sollwert normalerweise SP jedoch funktioniert das Ger t nach dem aktivierten Sollwert 3 HINWEISE ZUR INSTALLATION UND ZUM GEBRAUCH 3 1 BESTIMMUNGSGEMASSER GEBRAUCH Das Ger t wurde als Mess und Regelger t konzipiert und entspricht der Vorschrift EN61010 1 f r das Funktionieren zu H hen bis 2000 m Bei einem Gebrauch des Ger tes f r nicht ausdr cklich in dieser Vorschrift vorgesehene Anwendungen m ssen s mtliche Schutzma nahmen getroffen werden Das Ger t darf ohne angemessene Absicherung NICHT in explosionsgef hrdeter Atmosph re verwendet werden entz ndbarer oder explosiver Atmosph re Der Installateur hat sicherzustellen dass die Normen in bezug auf elektromagnetische Kompatibilit t auch nach Installation des Ger tes erf llt werden ggf durch Verwendung von Spezialfiltern Falls eine Betriebsst rung des Ger tes Personen oder Sachsch den verursachen kann muss die Anlage mit zus tzlichen elekt
106. in den OFF Regelzustand OFF und daraufhin auf die automatische Regelung rEG gestellt werden Die Dauer eines Autotuning Zyklus ist auf maximal 12 Stunden begrenzt Wurde der Vorgang innerhalb dieser 12 Stunden nicht abgeschlossen erscheint auf der Anzeige noAt Sollte hingegen eine F hlerst rung eintreten unterbricht das Ger t nat rlich den laufenden Zyklus Die vom Autotuning berechneten Werte werden automatisch vom Regler nach Abschluss eines ordnungsgem erfolgten Autotuning Zyklus in den entsprechenden Parametern der PID Regelung gespeichert Zur Aktivierung der SELFTUNING Funktion _ ist beschrieben vorzugehen 1 Den gew nschten Sollwert einstellen und aktivieren 2 Den Parameter Cont Pid einstellen 3 Bei Steuerung mit einfacher Wirkung ist der Parameter Func nach dem durch Ausgang 1 rEG zu berwachenden Prozess einzustellen 4 Einen Ausgang als 2 rEG konfigurieren wenn das Ger t eine Anlage mit doppelter Wirkung steuert 5 Den Parameter SELF yES stellen 6 Die Programmierung der Parameter verlassen 7 Das Ger t an die angesteuerte Anlage anschlie en 8 Das Selftuning im Men punkt tunE des Hauptmen s anw hlen oder ber die entsprechend programmierte Taste U Bei aktiver Selftuning Funktion leuchtet die Led AT ST fest und alle Parameter der PID Regelung Pb Int dEr usw werden nicht mehr angezeigt wie folgt Um das Autotuning abzubrechen oder das Selftuning zu d
107. ingle Loop Mikroprozessor mit EIN AUS Regelung EIN AUS im neutralen Bereich PID mit einfacher Wirkung oder PID mit doppelter Wirkung direkt und umgekehrt mit zwei Eing ngen f r Temperaturf hler vom Typ PTC oder NTC ber die die Regelung der Temperaturdifferenz ausgef hrt werden kann Der W rmeregler kann deshalb in Anwendungen bei denen eine Regelung in Abh ngigkeit von dem Temperaturunterschied zwischen zwei Bereichen wie z B Fl ssigk hler Chiller Umluftsysteme f r die nat rliche Raumk hlung Solarzellenheizung und in vielen anderen Anwendungen in denen zwei Temperaturmessungen erforderlich sind eingesetzt werden Der Regler verf gt au erdem ber die Funktionen AUTOTUNING Fast und Oszillierend SELFTUNNING und FUZZY OVERSHOOT CONTROL f r die PID Regelung Au erdem kann das Ger t auch mit 2 konfigurierbaren Digitaleingange und einer seriellen Kommunikationsschnittstelle TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 1 RS485 mit MODBUS RTU Kommunikationsprotokoll und einer max bertragungsgeschwindigkeit von 38400 Baud ausgestattet werden Der Istwert wird auf einer vierstelligen roten Anzeige angezeigt und der Sollwert ber 4 Leds Das Ger t verf gt zudem ber eine aus 3 Leds bestehende programmierbare Abweichungsanzeige Im Ger t k nnen bis zu 2 Sollwerte gespeichert werden und es kann ber bis zu 4 Relaisausg nge verf gen oder zur Steuerung von Statikrelais S
108. inguente UL 94 VO Dimensioni 78 x 35 mm prof 75 5 mm Peso 150 g circa Installazione Incasso a pannello in foro 71 x 29 mm Connessioni Morsettiera a vite 2 5 mm Grado di protezione frontale IP 65 con guarnizione Grado di polluzione 2 Temperatura ambiente di funzionamento 0 50 C Umidit ambiente di funzionamento 30 95 RH condensazione Temperatura di trasporto e immagazzinaggio 10 60 C senza 7 3 DIMENSIONI MECCANICHE FORATURA PANNELLO E FISSAGGIO mm 78 5 5 11 5 T TLK 31D 258 5 se amr co DW BRACKETS H EE Raglio Ng gt Rael Ag it E al Ve A N N be 5 E on D d EF h AL U min 15 mm WA 7 4 CARATTERISTICHE FUNZIONALI Regolazione ON OFF ON OFF a Zona Neutra PID a singola azione PID a doppia azione Range di misura Secondo la sonda utilizzata vedi tabella Risoluzione visualizzazione 1 0 0 1 Precisione totale 0 5 fs Tempo di campionamento misura 130 ms Tipo interfaccia seriale RS 485 isolata Protocollo di comunicazione MODBUS RTU JBUS Velocit di trasmissione seriale selezionabile 1200 38400 baud Display 4 Digit Rosso h 12 mm Conformita Direttiva CEE EMC 2004 108 CE EN 61326 Direttiva CEE
109. instructions for its maintenance and use we therefore recommend that the utmost attention is paid to the following instructions and to save it This document is the exclusive property of TECNOLOGIC S p A which forbids any reproduction and divulgation even in part of the document unless expressly authorized TECNOLOGIC S p A reserves the right to make any formal or functional changes at any moment and without any notice Whenever a failure or a malfunction of the device may cause dangerous situations for persons thing or animals please remember that the plant has to be equipped with additional devices which will guarantee safety Tecnologic S p A and its legal representatives do not assume any responsibility for any damage to people things or animals deriving from violation wrong or improper use or in any case not in compliance with the instruments features 1 INSTRUMENT DESCRIPTION 1 1 GENERAL DESCRIPTION 1 2 FRONT PANEL DESCRIPTION 2 PROGRAMMING 2 1 FAST PROGRAMMING OF SET POINT 2 2 SELECTION OF CONTROL STATE AND PARAMETER PROGRAMMING 2 3 PARAMETER PROGRAMMING LEVELS 24 CONTROL STATES 2 5 ACTIVE SET POINT SELECTION 3 INFORMATION ON INSTALLATION AND USE 3 1 PERMITTED USE 3 2 MECHANICAL MOUNTING 3 3 ELECTRICAL CONNECTIONS 3 4 ELECTRICAL WIRING DIAGRAM 4 FUNCTIONS 4 1 MEASURING AND VISUALIZATION 4 2 OUTPUTS CONFIGURATION 4 3 REGULATOR WITH ABSOLUTE OR DIFFERENTIAL TEMPERATURE 44 ON OFF CONTROL 45 NEUTRAL ZONE ON OFF CO
110. l Autotuning 6 Uscire dalla programmazione parametri 7 Collegare lo strumento all impianto comandato 8 Attivare l autotuning spegnendo e riaccendendo l apparecchio se Auto 10 2 oppure mediante la selezione della voce tunE nel men principale o mediante il tasto U opportunamente program mato se Auto 3 oppure ancora variando il valore di Set se Auto 4 A questo punto la funzione di Autotuning attivata e viene segna lata attraverso il led AT ST lampeggiante Il regolatore attua quindi una serie di operazioni sull impianto colle gato al fine di calcolare i parametri della regolazione PID pi idonei Qualora non siano verificate le condizioni di valore di pro cesso per avviare l Autotuning il display visualizzer ErAt ad in dicare l impossibilit di eseguire l operazione e lo strumento si por r nel normale modo di regolazione secondo i parametri impostati precedentemente Per far scomparire l errore ErAt sufficiente premere il tasto P La durata del ciclo di Autotuning limitata ad un massimo di 12 ore Nel caso in cui il processo non sia terminato nell arco di 12 ore lo strumento visualizzer noAt Nel caso invece si dovesse verificare un errore della sonda lo stru mento naturalmente interromper il ciclo in esecuzione I valori calcolati dall Autotuning saranno memorizzati automatica mente dallo strumento al termine della corretta esecuzione del ci clo di A
111. l gruppo InP Il parametro pu essere programmato come noF nessuna funzione Aac Chiudendo il contatto connesso all ingresso digitale 1 possibile resettare un allarme memorizzato vedi par 4 10 1 ASi Chiudendo il contatto connesso all ingresso digitale 1 possibile tacitare un allarme attivo vedi par 4 10 1 Hold Chiudendo il contatto connesso all ingresso digitale 1 viene bloccata l acquisizione della misura in quell istante N B non la lettura sul display quindi l indicazione potrebbe stabilizzarsi con un ritardo proporzionale al filtro di misura Con la funzione di hold inserita lo strumento opera la regolazione in funzione della misura memorizzata Riaprendo il contatto lo strumento riprende la normale acquisizione della misura OFF Quando lo strumento nello stato EG chiudendo il contatto connesso all ingresso digitale 1 lo strumento viene posto nello stato di OFF Riaprendo il contatto lo strumento ritorna nello stato di regolazione automatica rEG CHSP Chiudendo e riaprendo il contatto connesso all ingresso digitale 1 possibile selezionare a rotazione uno dei 4 Set Point memorizzati SP1 2 La chiusura del contatto connesso all ingresso digitale 1 seleziona come attivo il set point SP2 mentre l apertura del contat to seleziona come attivo il set point SP1 La funzione attuabile solo con nSP 2 inoltre quando attivata disabilita la selezione del set
112. ltet wird angegeben in Stunden und Minuten Die Funktionen sind deaktiviert Parameter auf InF gestellt werden Wenn es nur das Erreichung des Aktivsollwert bestand w nscht Beispiel SP1 es ist zum den Abs SLor gew nschten Wert zu gliedern zu beherrschter Schnelligkeit gen gend Die Rampe wird SLor sich immer zur Z ndung des Ger tes wirksam als erweisen und wenn es den Wert von Aktivsollwert gewechselt wird Wenn es jedoch w nscht von der Z ndung des Ger tes einen automatischen Zyklus zu verwirklichen ist es notwendig den Abs nSP zu programmieren 2 die zwei Sollwertes SP1 und SP2 gliedern und nat rlich mit den die Abs SLor dur t und SLoF gew nschten Werten Alle Rampen werden nicht in dieser Fall am Ende der Zyklus aktiver sein SV Unit wenn die entsprechenden SP1 change SP1 Value time imine SV U nit sp1 AUTO change Set time min Beispiele mit Start bei niedrigeren Werten als SP1 und Reduzierung des Sollwertes Hinweis Ist bei PID Regelung ein Autotuning durchzuf hren und eine Rampe aktiv wird diese nicht durchgef hrt solange der Einstellzyklus nicht abgeschlossen wurde Folglich muss das Autotuning ohne Rampe aktiviert und nach erfolgter Abstimmung wieder deaktiviert werden Auto OFF daraufhin sind die gew nschten Rampen zu programmieren und wird eine automatische Abstimmung gew nscht so ist die Selftuning Funktion zu aktivieren
113. mal rating ex for certain heating elements The function depends on the following parameters St P Soft Start power SSt Soft Start time expressed in hh mm HSEt End Soft Start cycle threshold If both parameters are programmed with values other than OFF when switched on the instrument gives an output power as programmed on par St P for the time programmed on par SSt or when is reached the absolute value programmed at par HSEt Practically the instrument works in manual condition and switches to automatic control at the elapsing of time SSt or when is reached the absolute value programmed at par HSEt To disable the Soft Start function simply program par SSt OFF Whenever a measurement errors occurs during the Soft Start execution the function is interrupted and the instrument gives an output power as programmed on par OPE If the measurement is restored the Soft Start is still deactivated If it s desired to activate the Autotuning with Soft Start set par Auto 4 The Autotuning will start automatically at the end of programmed Soft Start cycle at the condition that the process value is lower with Func HEAt than SP SP 5 or higher with Func CooL than SP SP 5 411 ALARMS OUTPUTS FUNCTIONS AL1 AL2 AL3 The alarms AL1 AL2 AL3 are depending on the process value and before to set his functioning it s necessary to establis
114. ment controlled by PV output 1rEG If par Prat 0 the output 2 rEG is disabled and the control behaves exactly as a single action PID controller through output 1 rEG SP 4 8 AUTOTUNING AND SELFTUNING FUNCTIONS All the parameters referring to the AUTO TUNING and SELF TUNING functions are contained in the group rEG time The AUTO TUNING and SELF TUNING functions permit the OUT L 7 EA 7 gt F automatic tuning of the PID controller fae S M M i i A A The AUTOTUNING function provides the calculation of the PID H Eat parameters through a FAST or OSCILLATORY type tuning cycle and at the end of this operation the parameters are stored into the i instrument s memory and remain constant during control The Single Action PID control algorithm foresees the setting ofthe The SELF TUNING function rule based TUNE IN instead allows ter1 ter1 tcri ter1 tcri tcri terl following parameters control monitoring and the continuous calculation of the parameters Pb Proportional Band during control ter1 Cycle time of the output 1rEG Both functions automatically calculate the following parameters Int Integral Time Pb Proportional Band rS Manual Reset if Int 0 only tcr1 Cycle time of the output 1 rEG dEr Derivative Time Int Integral Time FuOC Fuzzy Overshoot Control dEr Derivative Time This last parameter allows the variable overshoots
115. mento attuabile quando sono configurate 2 uscite rispettivamente come 1 rEG e 2 rEG e si ottiene programmando il par Cont nr Il funzionamento a Zona Neutra viene utilizzato per il controllo degli impianti che possiedono un elemento che causa un incremento positivo ad es Riscaldante Umidificante ecc e un elemento che causa un incremento Negativo ad es Refrigerante Deumidificante eCC TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 5 Il funzionamento di regolazione agisce sulle uscite configurate in funzione della misura del Set point SP attivo e dell isteresi HSEt programmati Il regolatore si comporta nel seguente modo spegne le uscite quando il valore di processo raggiunge il Set e attiva l uscita 1 rEG quando il valore di processo minore di SP HSEt oppure accende l uscita 2 rEG quando il valore di processo maggiore di SP HSEt Di conseguenza l elemento che causa incremento Positivo andr collegato all uscita configurata come 1 rEG mentre l elemento di incremento negativo andr collegato all uscita configurata come 2 rEG PV i de FF ef ASH heating SASA off off Gh OUT 2 rEG cooling Nel caso in cui l uscita 2 rEG venga utilizzata per il comando di un compressore prevista la funzione di protezione compressore da partenze ravvicinate Tale funzione prevede un controllo a tempo sull accensione dell uscita 2 rEG indipendentemente dalla ric
116. meters relative to alarm AL1 Par Description Range Def Note 24 OAL1 Output where alarm Out1 Out2 Out2 AL1 is addressed Out3 Out4 OFF 25 PrA1 AL1 alarm process Pr1 Pr2 Pri measurement reference P1 2 P1 L 26 AL1t Alarm AL1 type LoAb HiAb LoAb LoAb Absolute Low LHAb LodE HiAb Absolute High HidE LHdE LHAb Absolute Band LodE Deviation Low HidE Deviation High LHdE Deviation Band 27 Ab1 Alarm AL1 functioning 0 31 0 1 not activated at power on 2 delayed 4 latch 8 aknowledged 28 AL1 Alarm AL1 threshold AL1L AL1H 0 29 AL1L Low threshold band 1999 AL1H 1999 alarm AL1 or Minimum set alarm AL1 for high or low alarm 30 AL1H High threshold band AL1L 9999 9999 alarm AL1 or Maximum set alarm AL1 for high or low alarm 31 HAL1 Alarm AL1 hysteresis OFF 9999 1 32 AL1d Activation delay of OFF 9999 OFF alarm AL1 sec 33 AL1i Alarm AL1 activation in no yES no case of measuring error Group AL2 parameters relative to alarm AL2 Par Description Range Def Note 34 OAL2 Output where alarm Out1 Out2 OFF AL2 is addressed Out3 Out4 OFF 35 PrA2 AL2 alarm process Pr1 Pr2 Pr1 measurement reference P1 2 P1 L 36 AL2t Alarm AL2 type LoAb HiAb LoAb see AL1t LHAb LodE HidE LHdE 37 Ab2 Alarm AL2 functioning 0 31 0 see Ab1 38 AL2 Alarm AL2 threshold AL2L AL2H 0 39 AL2L Low threshold band 1999
117. mode is possible to program the minimum and the maximum set of AL1 by AL1L and AL1H parameters HidE DEVIATION HIGH ALARM The alarm is activated when the process value goes above the value SP AL1 and will be deactivated when it goes below the value SP AL1 HAL1 With this mode is possible to program the minimum and the maximum set of AL1 by AL1L and AL1H parameters j off HdE LHAb ABSOLUTE BAND ALARM The alarm is activated when the process value goes under the alarm threshold set on parameter TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 8 AL1L or goes higher than the alarm threshold set on parameter AL1H and will be deactivated when it goes below the value AL1H HAL1 or when it goes above the value AL1L HAL1 LHdE DEVIATION BAND ALARM The alarm is activated when the process value goes below the value SP AL1L or goes above than the value SP AL1H and will be deactivated when it goes below the value SP AL1H HAL1 or when it goes above the value SP AL1L HAL1 off Ab1 ALARM CONFIGURATION This parameter can assume a value between 0 and 31 The number to be set which will correspond to the function desired is obtained by adding the values reported in the following descriptions ALARM BEHAVIOUR AT SWITCH ON the alarm output may behave in two different ways depending on the value added to par
118. modified Start I SAE Active Set and Ser manua y alarm thresholds can 4 Start after Soft Start be modified or change Set Point SAnE Active Set and 62 SELF Selftuning enable no yES no alarm thresholds can 63 Pb Proportional band 0 9999 50 not be modified 64 Int Integral time OFF 9999 200 80 PASS Password ConF menu OFF 9999 OFF See Group SEr parameters relative to the serial communication 65 dEr Derivative time OFF 9999 50 Par Description Range Def Note sec 7 66 FuOc Fuzzy overshoot control 0 00 2 00 0 5 las a E A Ve 1 67 ter1 Cycle time of output 0 1 130 0 20 0 82 baud Transmission speed 1200 2400 9600 1rEg _ sec Baud rate 9600 19 2 68 Prat Power ratio 2 rEg 0 01 99 99 1 00 38 4 1 rEg 83 PACS Access at the LoCL LorE LorE 69 tcr2 Cycle time of 2 rEg 0 1 130 0 10 0 programming through SOC serial port 70 rS Manual reset 100 0 100 0 0 0 ren oo any 71 SLor Gradient of first ramp 0 00 99 99 InF remote progr InF Ramp not active InF unit min 6 PROBLEMS MAINTENANCE AND GUARANTEE 72 dur t Duration time between 0 00 99 59 InF two ramps InF 6 1 ERROR SIGNALLING InF Time not active hrs min Error Reason Action 73 SLoF Gradient of second 0 00 99 99 InF E1 The probe Pr1 may be Check the correct ramp i nF E1 interrupted or in short
119. molti PLC e programmi di supervisione disponibili sul mercato il manuale del protocollo di comunicazione degli strumenti della serie TLK disponibile a richiesta Il circuito d interfaccia consente di sulla stessa linea Per mantenere la linea in condizioni di riposo richiesto il collegamento di una resistenza Rt al termine della linea del valore di 120 Ohm Lo strumento dotato di due morsetti chiamati A e B che devono essere connessi a tutti i morsetti omonimi della rete Per il cablaggio della linea sufficiente quindi un doppino intrecciato di tipo telefonico Tuttavia in particolare quando la rete risulta molto lunga o disturbata consigliabile adottare un cavo a 3 poli intrecciato e schermato collegato come in figura Se lo strumento dotato di interfaccia seriale devono essere programmati i seguenti parametri tutti disponibili nel gruppo di parametri SEr Add Indirizzo della stazione Impostare un numero diverso per ogni stazione da 1 a 255 baud Velocit di trasmissione baud rate impostabile da 1200 a 38400 baud Tutte le stazioni devono avere la stessa velocit di trasmissione PACS Accesso alla programmazione Se impostato come LoCL significa che lo strumento programmabile solo da tastiera se impostato come LorE significa che programmabile sia da tastiera che tramite linea seriale collegare sino a 32 strumenti TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01
120. n abgebrochen und das Ger t sorgt daf r dass am Ausgang die im Parameter OPE eingestellte Leistung abgegeben wird Der Soft Start bleibt dennoch deaktiviert auch wenn die Messung wiederhergestellt wurde Wenn es w nscht den Autotuning mit dem Soft Start auszuf hren steckt ein es ist notwendig den Abs Auto 4 oder 4 zu programmieren Auf diese Art und Weise wird der autotuning am Ende der Zyklus von Soft Start ausgef hrt werden nat rlich der Istwert kleiner bei Func HEAt als SP SP 5 oder gr er bei Func CooL als SP SP 5 4 11 ALARMBETRIEB AL1 AL2 AL3 Zur Betriebskonfiguration der Alarme deren Ansprechen mit dem Istwert AL1 AL2 AL3 verbunden ist muss vorher bestimmt werden welchem Ausgang der Alarm entsprechen soll Herzu m ssen zun chst in der Parametergruppe Out die Parameter der Ausg nge die als Alarme O1F O2F O3F verwendet werden sollen konfigurieren werden indem der Parameter des gew nschten Ausgangs programmiert wird ALno wenn der Alarmausgang bei aktivem Alarm aktiviert werden soll und bei nicht aktivem Alarm deaktiviert sein soll ALnc wenn der Alarmausgang bei deaktiviertem Alarm aktiviert werden soll und bei aktivem Alarm deaktiviert sein soll ALni wenn es das gleiche Funktionieren von ALnc w nscht aber mit Funktionieren des verneinten Vorder led zeigt der Vorder led des Ger tes den Staat des Ausganges in dieser Fall an
121. n error conditions the instrument provides an output power as programmed on par OPE and activates the desired alarms if the relative parameters ALni have been programmed yES 6 2 CLEANING We recommend cleaning of the instrument with a slightly wet cloth using water and not abrasive cleaners or solvents which may damage the instrument 6 3 GUARANTEE AND REPAIRS The instrument is under warranty against manufacturing flaws or faulty material that are found within 12 months from delivery date The guarantee is limited to repairs or to the replacement of the instrument The eventual opening of the housing the violation of the instrument or the improper use and installation of the product will bring about the immediate withdrawal of the warranty s effects In the event of a faulty instrument either within the period of warranty or further to its expiry please contact our sales department to obtain authorisation for sending the instrument to our company The faulty product must be shipped to TECNOLOGIC with a detailed description of the faults found without any fees or charge for Tecnologic except in the event of alternative agreements 7 TECHNICAL DATA 7 1 ELECTRICAL DATA Power supply 12 VAC VDC 10 Frequency AC 50 60 Hz Power consumption 4 VA approx Input s 2 inputs for temperature probes PTC KTY 81 121 990 Q 25 C NTC 103AT 2 10KQ 25 C 2 digital inputs for free voltage contacts Ou
122. na potenza troppo elevata forni ta quando questi non ancora in condizioni di regime ad esempio nel caso di alcuni elementi riscaldanti Il funzionamento stabilito dai seguenti parametri St P Potenza di Soft Start SSt Tempo massimo di Soft Start espresso in hh mm HSEt Soglia disabilitazione ciclo Soft Start Una volta impostati i parametri ai valori desiderati all accensione lo strumento provveder a fornire in uscita la potenza impostata al par St P per il tempo impostato al par SSt o sino al raggiungi mento del valore assoluto impostato al par HSEt In pratica lo strumento opera in regolazione manuale per commuta re automaticamente in regolazione automatica al termine del tempo SSt o quando il valore di processo uguale al valore pro grammato al par HSEt Per escludere la funzione di Soft Start sufficiente impostare il par SSt OFF Qualora durante l esecuzione del Soft Start si verifichi un errore di misura la funzione viene interrotta e lo strumento passa a fornire in uscita la potenza impostata al par OPE Se la misura si ripristina il Soft Start rimane comunque disattivato Se si desidera eseguire l Autotuning con il Soft Start inserito oc corre programmare il par Auto 4 4 In questo modo l autotuning verr eseguito al termine del ciclo di Soft Start 4 11 FUNZIONAMENTO DELLE USCITE DI ALLARME AL1 AL2 AL3 Per
123. ndite TECNOLOGIC per ottenere l autorizzazione alla spedizione Il prodotto difettoso quindi accompagnato dalle indicazioni del difetto riscontrato deve pervenire con spedizione in porto franco presso lo stabilimento TECNOLOGIC salvo accordi diversi 7 DATI TECNICI 7 1 CARATTERISTICHE ELETTRICHE Alimentazione 12 VAC VDC 10 Frequenza AC 50 60 Hz Assorbimento 4 VA circa TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 13 Ingresso i 2 ingressi per sonde di temperatura PTC KTY 81 121 990 Q 25 C o NTC 103AT 2 10KQ 25 C 2 ingressi digitali per contatti liberi da tensione Uscita e Sino a 4 uscite A rel 2 SPDT e 2 SPST NO 8 A AC1 3 A AC3 250 VAC o in tensione per pilotaggio SSR 10mA 10VDC Vita elettrica uscite a rel 100000 operaz Categoria di installazione II Categoria di misura Classe di protezione contro le scosse elettriche Frontale in Classe Il Isolamenti Rinforzato tra parti in bassa tensione uscite a rel e frontale Rinforzato tra parti in bassa tensione uscite a rel e parti in bassissima tensione alimentazione ingresso e uscite statiche Rinforzato tra alimentazione e uscite a rel Nessun isolamento tra alimentazione e ingresso Nessun isolamento tra alimentazione ingresso e uscite statiche Isolamento a 50 V tra RS485 e parti in bassissima tensione 7 2 CARATTERISTICHE MECCANICHE Contenitore Plastico autoest
124. ng to the previously programmed parameters To make the error ErAt disappear press key P The Auto tuning cycle duration has been limited to 12 hours maximum If Auto tuning is not completed within 12 hours the instrument will show noAt on the display In case of probe error the instrument automatically stops the cycle in progress The values calculated by Auto tuning are automatically stored in the instrument s memory at the end of the correct PID parameters tuning To activate the SELF TUNING function proceed as follows 1 Program and activate the desired Set Point 2 Program par Cont Pid 3 Program par Func according to the process to be controlled through output 1rEG 4 Program an output as 2rEG if the instrument controls a dual action plant 5 Program par SELF yES 6 Exit from the parameter programming 7 Connect the instrument to the controlled plant 8 Activate Self tuning selecting par tunE in the main menu or by correctly programming key U When the Self tuning function is active the led AT ST is permanently lit up and all the PID parameters Pb Int dEr etc are no longer visualized To stop the Auto tuning cycle or deactivate the Self tuning function select one of the control types rEG OPLO or OFF from the menu SEL If the instrument is switched off during Auto tuning or with the Self tuning function activated these functions will remain activated t
125. ng ausschalten 5 Led OUT1 Signalisiert den Zustand des Ausgangs OUT1 6 Led OUT2 Signalisiert den Zustand des Ausgangs OUT2 7 Led OUTS Signalisiert den Zustand des Ausgangs OUT3 8 Led OUT4 Signalisiert den Zustand des Ausgangs OUT4 9 Led SET Blinkend signalisiert diese Led den Zugriff auf den Programmiermodus 10 Led AT ST Signalisiert dass die Selftuning Funktion eingeschaltet ist leuchtet bzw das Autotuning gerade l uft blinkt 11 Led Abweichungsindex Signalisiert dass der Ist Wert den im Parameter AdE eingegebenen Wert unterschritten hat 12 Led Abweichungsindex Signalisiert dass der Ist Wert im Bereich SP AdE SP AdE liegt 13 Led Abweichungsindex Signalisiert dass der Ist Wert den im Parameter AdE eingegebenen Wert Uberschritten hat 2 PROGRAMMIERUNG 2 1 SCHNELLEINSTELLUNG DER SOLLWERTE Anhand dieses Vorgangs l sst sich der aktive Sollwert und ggf die Alarmgrenzwerte schnell einstellen siehe Abschnitt 2 3 Die Taste P kurz dr cken auf der Anzeige erscheint SP n n steht f r die Nummer des zu diesem Zeitpunkt aktiven Sollwertes und abwechselnd der eingestellte Wert Erh ht wird der Wert anhand der Taste UP reduziert wird er anhand der Taste DOWN Bei Bet tigung dieser Tasten steigt oder sinkt der Wert um eine Einheit werden die Tasten hingegen mindestens eine Sekunde gedr ckt gehalten steigt bzw sinkt der Wert schnell und nach zwei Sekunden n
126. nte dell uscita di regolazione In questo caso si raccomanda l uso di un rel statico SSR per il comando dell attuatore L algoritmo di regolazione PID a singola azione dello strumento prevede l impostazione dei seguenti parametri Pb Banda Proporzionale ter1 Tempo di ciclo dell uscita 1rEG Int Tempo Integrale rS Reset manuale solo se Int 0 dEr Tempo derivativo FuOC Fuzzy Overshoot Control Quest ultimo parametro premette di eliminare le sovraelongazioni della variabile overshoot all avviamento del processo o al cambiamento del Set Point Occorre tener presente che un valore basso del parametro riduce l overshoot mentre un valore alto lo aumenta time 1 Valore FuOC OK 2 Valore FuOC troppo alto 3 Valore FUOC troppo basso 4 7 REGOLATORE PID A DOPPIA AZIONE 1 rEG 2 rEG Tutti i parametri riguardanti la regolazione PID sono contenuti nel gruppo IrEG La regolazione PID a Doppia Azione viene utilizzata per il controllo degli impianti che possiedono un elemento che causa un incremento positivo ad es Riscaldante e un elemento che causa un incremento negativo ad es Raffreddante e viene attuata quando sono configurate 2 uscite rispettivamente come 1 rEG e 2 rEG e programmando il par Cont Pid L elemento che causa incremento Positivo andr collegato all uscita configurata come 1rEG mentre l elemento di incremento negativo andr coll
127. och schneller wodurch der gew nschte Wert schnell erreicht wird Wurde der gew nschte Wert eingestellt und die Taste P gedr ckt wird der Schnelleinstellmodus verlassen bzw auf der Anzeige erscheinen die Alarmgrenzwerte siehe Abschnitt 2 3 Der Schnelleinstellmodus wird nach Dr cken der Taste P nach Anzeige des letzten Sollwertes verlassen oder automatisch wenn ca 15 Sekunden lang keine Taste mehr gedr ckt wurde Daraufhin kehrt die Anzeige zum normalen Betriebsmodus zur ck 2 2 WAHL DER REGELZUST NDE UND PROGRAMMIERUNG DER PARAMETER Wird die Taste P ca 2 Sekunden lang gedr ckt gehalten ffnet sich das Hauptmen Anhand der Tasten UP oder DOWN werden die verschiedenen Wahlm glichkeiten angezeigt OPEr ffnet das Men der Betriebsparameter ConF ffnet das Men der Konfigurationsparameter OFF versetzt den Regler in den FF Zustand rEG aktiviert den automatischen Regelzustand des Reglers tunE Aktiviert die Autotuning oder Selftuning Funktion OPLO aktiviert die Handregelung des Reglers und erm glicht eine Einstellung des Regelwertes in anhand der Tasten UP und DOWN Wurde der gew nschte Men punkt angew hlt wird er durch Dr cken der Taste P best tigt Die Men punkte OPEr und ConF ffnen Untermen s mit verschiedenen Parametern und zwar OPEr Men der Betriebsparameter Dieses enth lt normalerweise die Einstellparameter der Sollw
128. on PID Measurement range according to the used probe see range table Display resolution according to the probe used 1 0 1 0 01 0 001 Overall accuracy 0 5 fs 1 digit Sampling rate 130 ms Serial Interface RS485 insulated Communication protocol MODBUS RTU JBUS Baud rate Programmable from 1200 38400 baud Display 4 Digit Red h 12 mm Compliance ECC directive EMC 2004 108 CE EN 61326 ECC directive LV 2006 95 CE EN 61010 1 7 5 MEASURING RANGE TABLE INPUT dP 0 dP 1 PTC KTY81 121 55 150 C 55 0 150 0 C SEnS Ptc 67 302 F 67 0 302 0 F NTC 103 AT2 50 110 C 50 0 110 0 C SEnS ntc 58 230 F 58 0 230 0 F 7 6 INSTRUMENT ORDERING CODE TLK31abcdefghhD a INPUTS T thermistors PTC NTC TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 13 b OUTPUT OUT1 R Relay O VDC for SSR c OUTPUT OUT2 R Relay O VDC for SSR None d OUTPUT OUT3 R Relay O VDC for SSR None e OUTPUT OUT4 R Relay O VDC for SSR None f COMMUNICATION INTERFACE S RS 485 Serial interface No interface g DIGITAL INPUTS l 2 digital inputs None hh SPECIAL CODES TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 14 Ww TLK 31 D ELEKTRONISCHER W RMEREGLER MI
129. one da attuare mediante i tasti UP e DOWN Una volta selezionata la voce desiderata premere il tasto P per confermarla Le selezioni OPEr e ConF fanno accedere a sottomen contenenti pi parametri e precisamente OPEr Men parametri operativi contiene normalmente i parametri di impostazione dei Set point ma pu contenere tutti i parametri desiderati vedi par 2 3 ConF Men parametri di configurazione contiene tutti i parametri operativi e i parametri di configurazione funzionamento Configurazione allarmi regolazione ingresso ecc EG P 20B08_ zZ A CE GE A Hold for Vv 2sec 4 LP OPEL HE A W Conf 757 A vy sn OFF OFF POF F_ lt 3 A V AUTOTUNING ry t SELFTUNING kun 4 P e AY tse OPLO OPLO poeta I TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 2 Per accedere al men OPEr selezionare quindi l opzione OPEr e premere il tasto P A questo punto il display visualizzer il codice che identifica il primo gruppo di parametri SP e con i tasti UP e DOWN sar possibile selezionare il gruppo di
130. ontrol are contained in the group IrEG This type of control can be obtained by programming par Cont On FS or On FA and works on the output programmed as 1 rEG depending on the measure on the active Set Point SP on the functioning mode Func and on the hysteresis HSEt The instrument carries out an ON OFF control with symmetric hysteresis if Cont On FS or with asymmetrical hysteresis if Cont On Fa OUT 1 rEG HEAt On FS CooL On FS The control works in the following way in the case of reverse action or heating FunC HEAt it deactivates the output when the process value reaches SP HSEt in case of symmetrical hysteresis or SP in case of asymmetrical hysteresis and is then activated again when the process value goes below value SP HSEt Vice versa in case of direct action or cooling Func CooL it deactivates the output when the process value reaches SP HSEt in case of symmetrical hysteresis or SP in case of asymmetrical hysteresis and is activated again when the process value goes above value SP HSEt 4 5 NEUTRAL ZONE ON OFF CONTROL 1 rEG 2 rEG All the parameters referring to Neutral Zone ON OFF control are contained in the group IrEG This type of control can be obtained when 2 outputs are programmed respectively as 1 rEG and 2 rEG and the par Cont nr The Neutral Zone control is used to control plants in which there i
131. oup Out programming the parameter as ALno if the alarm output has to be ON when the alarm is active while it is OFF when the alarm is not active ALnc if the alarm output has to be ON when the alarm is not active while it is OFF when the alarm is active ALni if the alarm output has to be ON when the alarm is not active while it is OFF when the alarm is active but with reverse led indication led ON alarm OFF Enter group LbA and program which output the alarm signal has to be addressed to on par OLbA The Loop Break alarm is activated if the output power remains at the 100 of the value for the time programmed on par LbAt expressed in sec To avoid false alarms the value of this parameter has to be set considering the time the plant takes to reach the Set point when the measured value is a long distance from it for example at the plant start up On alarm intervention the instrument visualizes the message LbA and behaves as in the case of a measurement error giving a power output as programmed on par OPE programmable in the group InP To restore normal functioning after the alarm select the control mode OFF and then re program the automatic control rEG after checking the correct functioning of probe and actuator To exclude the Loop Break alarm set OLbA OFF 4 13 FUNCTIONING OF KEY U The function of key U can be set through par USrb
132. parametri che si intende editare Una volta selezionato il gruppo di parametri desiderato premere il tasto P e verr visualizzato il codice che identifica il primo parametro del gruppo selezionato Sempre con i tasti UP e DOWN si pu selezionare il parametro desiderato e premendo il tasto P il display visualizzer alternativamente il codice del parametro e la sua impostazione che potr essere modificata con i tasti UP o DOWN Impostato il valore desiderato premere nuovamente il tasto P il nuovo valore verr memorizzato e il display mostrer nuovamente solo la sigla del parametro selezionato Agendo sui tasti UP o DOWN quindi possibile selezionarne un altro parametro se presente e modificarlo come descritto Per tornare a selezionare un altro gruppo di parametri mantenere premuto il tasto UP o il tasto DOWN per circa 2 sec trascorsi i quali il display torner a visualizzare il codice del gruppo di parametri Rilasciare quindi il tasto premuto e con i tasti UP e DOWN sar possibile selezionare un altro gruppo se presente Per uscire dal modo di programmazione non agire su alcun tasto per circa 20 secondi oppure mantenere premuto il tasto UP o DOWN sino ad uscire dalla modalit di programmazione Per accedere al men ConF potrebbe essere invece richiesta una PASSWORD personalizzabile attraverso il par PASS Qualora si desideri disporre di questa protezione impostare al pa rametro PASS il numero di password des
133. po OSCILLATORIO terminato il quale i parametri vengono memoriz zati dallo strumento e durante la regolazione rimangono costanti TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 6 La funzione di SELFTUNING rule based TUNE IN prevede inve ce il monitoraggio della regolazione ed il continuo ricalcolo dei pa rametri durante la regolazione Entrambe le funzioni calcolano in modo automatico i seguenti parametri Pb Banda Proporzionale ter1 Tempo di ciclo dell uscita 1 rEG Int Tempo Integrale dEr Tempo derivativo FuOC Fuzzy Overshoot Control e per la regolazione PID a doppia azione anche ter2 Tempo di ciclo dell uscita 2 rEG Prat Rapporto P 2 rEG P 1 rEG Per attivare la funzione di AUTOTUNING procedere come segue 1 Impostare ed attivare il Set point desiderato 2 Impostare il parametro Cont Pid 3 Se il controllo a singola azione impostare il parametro Func in funzione del processo da controllare attraverso l uscita 1 rEG 4 Configurare un uscita come 2 rEG se lo strumento comanda un impianto con doppia azione 5 Impostare il parametro Auto come 1 se si desidera che l autotuning FAST venga avviato automati camente ogni volta che si accende lo strumento a condizione che il valore di processo sia minore per Func HEAt di SP SP 2 o maggiore per Func CooL di SP SP 2 2 se si desidera che l autotuning FA
134. re il ritardo impostato al par AL1d espresso in sec e solo trascorso tale tempo l allarme verr attivato MEMORIA ALLARME Si possono avere 2 differenti comportamenti dell uscita di allarme a seconda del valore sommato al par Ab1 0 ALLARME NON MEMORIZZATO L allarme rimane attivo so lo nelle condizioni di allarme 4 ALLARME MEMORIZZATO L allarme si attiva quando vi so no le condizioni di allarme e rimane attivo anche se tali condizioni non permangono sino a quando non viene premuto il pulsante U se opportunamente programmato USrb Aac o interviene l ingresso digitale 1 opportunamente programmato diF Aac Nell esempio il comportamento rappresentato con un allarme di massima assoluto TACITAZIONE ALLARME Si possono avere 2 differenti comporta menti dell uscita di allarme a seconda del valore sommato al par Ab1 0 ALLARME NON TACITABILE L allarme rimane sempre attivo nelle condizioni di allarme 8 ALLARME TACITABILE L allarme si attiva quando vi sono le condizioni di allarme e pu essere disattivato mediante il pulsante U se opportunamente programmato USrb ASi o interviene l in gresso digitale 1 opportunamente programmato diF ASi anche se le condizioni di allarme permangono COMPORTAMENTO ALLARME AL CAMBIO DEL SET POINT SOLO PER ALLARMI RELATIVI Si possono avere 2 differenti comportamenti dell uscita di allarme a seconda del valore somma
135. rogrammed on par SPHL Note in all the following examples the Set point is indicated as SP however the instrument will act according to the Set point selected as active 3 INFORMATION ON INSTALLATION AND USE 3 1 PERMITTED USE The instrument has been projected and manufactured as a measuring and control device to be used according to EN61010 1 for the altitudes operation until 2000 ms TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 3 The use of the instrument for applications not expressiy permitted by the above mentioned rule must adopt all the necessary protective measures The instrument CANNOT be used in dangerous environments flammable or explosive without adequate protection The installer must ensure that EMC rules are respected also after the instrument installation if necessary using proper filters Whenever a failure or a malfunction of the device may cause dangerous situations for persons thing or animals please remember that the plant has to be equipped with additional devices which will guarantee safety 3 2 MECHANICAL MOUNTING The instrument in case 78 x 35 mm is designed for flush in panel mounting Make a hole 71 x 29 mm and insert the instrument fixing it with the provided special brackets We recommend that the gasket is mounted in order to obtain the front protection degree as declared Avoid placing the instrument in environments with very high humidi
136. romechanischen Schutzeinrichtungen abgesichert werden 3 2 MECHANISCHER EINBAU Das Ger t befindet sich in einem 78 x 35 mm Geh use und ist f r den Schalttafeleinbau vorgesehen Es wird in eine 29 x 71 mm Aussparung gesetzt und daraufhin mit dem vorgesehenen Klemmb gel befestigt Es wird darauf hingewiesen dass zur Gew hrleistung der angegebenen Front Schutzart die zur Ausstattung geh rende Dichtung zu verwenden ist Die Innenseite des Ger tes sollte weder Staub noch starker Feuchtigkeit ausgesetzt werden da sich Kondenswasser bilden k nnte oder in das Ger teinnere leitende Teile oder Stoffe gelangen k nnten Au erdem ist sicherzustellen dass das Ger t ausreichend bel ftet ist ein Einbau in Bereichen in denen sich Einrichtungen befinden die einen Betrieb des Reglers au erhalb der angegebenen Temperaturgrenzwerte verursachen k nnten ist unbedingt zu vermeiden Das Ger t ist so weit wie m glich entfernt von Quellen die starke elektromagnetische St rungen verursachen k nnten d h von Motoren Sch tzen Relais Magnetventilen usw zu installieren 3 3 ELEKTRISCHE ANSCHL SSE Das Ger t anschlie en dazu jeweils einen Leiter je Klemme anschlie en und entsprechend beiliegendem Anschlussschema vorgehen dabei sicherstellen dass die Netzspannung den Hinweisen auf dem Ger t entspricht und der Anschlusswert der am TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 Ger t angeschlossenen Verbraucher
137. rt FuOC zu hoch 3 Wert FuOC zu niedrig 4 7 PID REGELUNG MIT DOPPELTER WIRKUNG 1 rEG 2 rEG Alle Parameter der PID Regelung befinden sich in der Gruppe EG Die PID Regelung mit doppelter Wirkung wird zur Steuerung von Anlagen verwendet die ber ein Element verf gen das einen positiven Anstieg erzeugt z B Heizen und ber ein Element das einen negativen Anstieg z B K hlen Die Funktion wird aktiviert wenn 2 Ausg nge als 1 rEG und 2 rEG konfiguriert und der Parameter Cont Pid gestellt wurde Das den positiven Anstieg erzeugende Element muss an den als 1 rEG konfigurierten Ausgang angeschlossen werden w hrend das den negativen Anstieg erzeugende Element an den als 2 rEG konfigurierten Ausgang angeschlossen wird Die PID Regelung mit doppelter Wirkung wirkt folglich auf die Ausg nge 1 rEG und 2 rEG nach dem aktiven Sollwert SP und dem Ergebnis des 2 stufigen PID Regelalgorithmus des Ger tes Zur Gew hrleistung einer guten Stabilit t der Variable bei schnellen Abl ufen m ssen die Zykluszeiten tcr1 und tcr2 niedrig sein und die Regelausg nge h ufig ansprechen In diesem Fall sollte ein Statikrelais SSR zur Steuerung der Verbraucher verwendet werden F r den PID Regelalgorithmus mit doppelter Wirkung des Ger tes k nnen die folgenden Parameter eingestellt werden Pb Proportionalband tcr1 Zykluszeit von Ausgang 1 rEG tcr2 Zykluszeit von Ausgang 2 rEG
138. rt SP AL1H berschreitet off Ab1 ALARMKONFIGURATION Der Parameter kann einen Wert zwischen O und 31 annehmen Die einzugebende Zahl die der entspricht ergibt sich aus der beschriebenen Werte ALARMVERHALTEN BEI EINSCHALTUNG Der Alarmausgang verh lt sich je nach dem im Parameter Ab1 summierten Wert auf 2 verschiedene Arten 0 NORMALES VERHALTEN Der Alarm wird bei einem Alarmzustand stets aktiviert 1 BEI EINSCHALTUNG NICHT AKTIVER ALARM Befindet sich das Ger t bei Einschaltung in einem Alarmzustand wird dieser nicht aktiviert Der Alarm wird lediglich aktiviert wenn der Istwert nach erfolgter Einschaltung nicht den alarmfreien Zustand und dann den Alarmzustand erreicht hat gew nschten Betriebsart Summe der nachstehend TECNOLOGIC spa TLK 31 D BEDIENUNGSANLEITUNG Vr 02 ISTR MTLK31DDEU2 PAG 9 Beispiel mit ABSOLUTER TIEFSTWERTALARM ALARMVERZ GERUNG Der Alarmausgang verh lt sich je nach dem im Parameter Ab1 summierten Wert auf 2 verschiedene Arten 0 NICHT VERZ GERTER ALARM Der Alarm wird sofort beim Auftreten des Alarmzustands aktiviert 2 VERZ GERTER ALARM Beim Auftreten eines Alarmzustands startet die im Parameter AL1d eingegebene Verz gerung angegeben in Sekunden und erst nach Ablauf dieser Zeit wird der Alarm aktiviert ALARMSPEICHER Der Alarmausgang verh lt sich je nach dem im Parameter Ab1 summierten Wert auf 2 verschiedene Ar
139. rte editierbar SAE Sowohl aktive Sollwert als auch die Alarmgrenzwerte sind editierbar SAnE Weder aktive Sollwert noch die Alarmgrenzwerte sind editierbar 80 PASS Passwort f r den Zugriffl OFF 9999 OFF auf die Betriebsparameter Gruppe SEr Parameter der seriellen Kommunikation Par Beschreibung Bereich Def Note 81 Add Stationsadresse fir 0 255 1 serielle Kommunikation 82 baud Baud rate serieller Port 1200 2400 9600 9600 19 2 38 4 83 PACS Zugriff auf die LoCL LorE LorE Programmierung ber seriellen Port LoCL Ger t lediglich ber die Tastatur programmierbar LorE Ger t sowohl ber die Tastatur als auch ber den seriellen Port programmiert 6 ST RUNGEN WARTUNG UND GARANTIE 6 1 FEHLERMELDUNGEN und der Verbraucher auf ihre Funktionst chtigkeit berpr ft wurden Die Taste P dr cken ErEP M gliche St rung im EEPROM Speicher Bei einem Messfehler gibt das Ger t am Ausgang die im Parameter OPE eingestellte Leistung ab und aktiviert alle gew nschten Alarme wenn bei den entsprechenden Parametern ALni yES eingegeben wurde 6 2 REINIGEN Es wird empfohlen das Ger t mit einem feuchten Tuch mit etwas Wasser oder mit einem l sungsmittelfreien leichten Reinigungsmittel zu reinigen 6 3 GEW HRLEISTUNG UND INSTANDSETZUNG Das Ger t hat ab Lieferdatum eine Gar
140. s an element which causes a positive increase ex Heater humidifier etc and an element which causes a negative increase ex Cooler de humidifier etc The control functions works on the programmed outputs depending on the measurement on the active Set Point SP and on the hysteresis HSEt The control works in the following way it deactivates the outputs when the process value reaches the Set Point and it activates the output 1 rEG when the process value goes below value SP HSEt or it activates the output 2 rEG when the process value goes above SP HSEt TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 ISTR MTLK31DENG2 PAG 5 Consequently the element causing a positive increase has to be Please remember that a low value on this parameter reduces the connected to the output programmed as 1rEG while the element overshoot while a high value increase it causing a negative increase has to be connected to the output programmed as 2 rEG ES SP PV lt _ N a EN A i sl cifra 1 Value FuOC OK OUT 1 rEG 2 Value FuOC too high heating 3 Value FuOC too low OUT 2 rEG cooling 4 7 DOUBLE ACTION PID CONTROL 1 rEG 2 rEG All the parameters referring to PID control are contained in the If 2 rEG output is used to control compressor is possible to use the group IrEG Compressor Protection function that has the meaning to avoid The Double Action PID control is
141. s been chosen through the Unit parameter it is possible to choose the temperature measurement unit C or F and through the dP parameter the resolution of the measurement desired 0 1 1 0 1 If the Pr2 probe is not used set the Pr2 parameter NO to avoid an error being indicated when the probe is not connected The instrument allows for measuring calibration which may be used to recalibrate the instrument according to application needs by using par OFSt and rot Programming par rot 1 000 in par OFSt it is possible to set a positive or negative offset that is simply added to the value read by the probe before visualisation which remains constant for all the measurements If instead it is desired that the offset set should not be constant for all the measurements it is possible to operate the calibration on any two points In this case in order to decide which values to program on par OFSt and rot the following formulae must be applied rot D2 D1 M2 M1 OFSt D2 rot x M2 where M1 measured value 1 D1 visualisation value when the instrument measures M1 M2 measured value 2 D2 visualisation value when the instrument measures M2 It then follows that the instrument will visualise DV MV x rot OFSt where DV visualised value MV measured value Example 1 It is desired that the instrument visualises the value effectively m
142. s less for Func HEAt than SP SP 2 or greater for Func CooL than SP SP 2 For Auto 3 or 4 the process value is less for Func HEAt than SP SP 5 or greater for Func CooL than SP SP 5 The FAST autotuning is not indicated when the Set point is close to the initial reading or when the variable measured varies in an ir regular way during the tuning cycle for reasons due to the process the variable rises or decreases In these cases it is advisable to use the Oscillatory type Autotuning which implements some ON OFF regulation cycles that make the process value oscillate around the Set point values that once finis hed pass to the PID type regulation with parameters calculated by the Autotuning 6 Exit from the parameter programming 7 Connect the instrument to the controlled plant 8 Activate the Auto tuning by switch off and turn on the instrument if Auto 1 or 2 or by selecting par tunE in the main menu or by correctly programming key U At this point the Auto tuning function is activated and is indicated by the flashing led AT ST The regulator carries out several operations on the connected plant in order to calculate the most suitable PID parameters If at the Auto tuning start the condition for the lower or higher process value is not found the display will show ErAt and the instrument will be swapped to normal control conditions accordi
143. scomparire l errore sono verificate le Provare quindi a condizioni per poterlo ripetere l autotuning avviare quando le condizioni lo permettono noAt Autotuning non terminato Provare a ripetere l au entro 12 ore totuning dopo aver con trollato il funzionamento della sonda e dell attuatore LbA Interruzione dell anello di Rimettere lo strumento regolazione Loop break nello stato di regolazio alarm ne rEG dopo aver con trollato il funzionamento della sonda e dell attuatore ErEP Possibile anomalia nella Premere il tasto P memoria EEPROM In condizioni di errore di misura lo strumento provvede a fornire in uscita la potenza programmata al par OPE e provvede ad attivare le uscite di allarme se il relativo par ALni programmato yES 6 2 PULIZIA Si raccomanda di pulire lo strumento solo con un panno leggermente imbevuto d acqua o detergente non abrasivo e non contenente solventi 6 3 GARANZIA E RIPARAZIONI Lo strumento garantito da vizi di costruzione o difetti di materiale riscontrati entro i 12 mesi dalla data di consegna La garanzia si limita alla riparazione o la sostituzione del prodotto L eventuale apertura del contenitore la manomissione dello strumento o l uso e l installazione non conforme del prodotto comporta automaticamente il decadimento della garanzia In caso di prodotto difettoso in periodo di garanzia o fuori periodo di garanzia contattare l ufficio ve
144. sollte ein abgeschirmtes 3 aderiges Flechtkabel verwendet und entsprechend Abbildung angeschlossen werden Ist das Ger t mit einer seriellen Schnittstelle ausgestattet so sind die nachstehenden und alle in der Gruppe SEr enthaltenen Parameter zu programmieren Add Stationsadresse F r jede Station eine andere Nummer eingeben 1 bis 255 baud bertragungsgeschwindigkeit baud rate einstellbar auf einen Wert zwischen 1200 und 38400 Baud F r alle Stationen muss die gleiche bertragungsgeschwindigkeit eingegeben werden PACS Zugriff auf die Programmierung Wird LoCL eingegeben ist das Ger t nur ber die Tastatur programmierbar wird hingegen LorE eingegeben kann sowohl ber die Tastatur als auch ber die serielle Leitung programmiert werden Bei Zugriff auf die Programmierung ber die Tastatur w hrend eine Kommunikation ber die serielle Schnittstelle l uft erscheint auf der Anzeige die Meldung buSy und weist damit auf den Zustand belegt hin HOST PC PLC shield A Im B 120 ohm RS485 i Interface GN A B GND A B GND A B GND 10 8 9 1018 9 10 8 9 TLK31 n 1 TLK31 n 2 TLK31 n N 4 16 KONFIGURATION DER PARAMETER MIT ODER A01 Das Ger t verf gt ber eine Steckbuchse die eine bertragung der Betriebsparameter von und zum
145. sotto del valore SP AL1L oppure quando il valore di processo sale al di sopra del valore SP AL1H e si disattiva quando rientra nel campo SP AL1H HAL1 SP AL1L HAL 1 LHAb LHdE Ab1 CONFIGURAZIONE DELL ALLARME Il parametro pu assumere un valore compreso tra 0 e 31 Il numero da impostare che corrisponder al funzionamento desi derato viene ottenuto sommando i valori riportati nelle seguenti descrizioni COMPORTAMENTO ALLARME ALL ACCENSIONE Si possono avere 2 differenti comportamenti dell uscita di allarme a seconda del valore sommato al par Ab1 0 COMPORTAMENTO NORMALE L allarme viene attivato sempre quando vi sono le condizioni di allarme 1 ALLARME NON ATTIVO ALL AVVIAMENTO Se all avviamen to lo strumento si trova nelle condizioni di allarme questo non viene attivato L allarme si attiver solo quando il valore di processo do po l accensione non si portato nelle condizioni di non allarme e successivamente nelle condizioni di allarme PV AL1 Nell esempio il comportamento rappresentato con un allarme di minima assoluto RITARDO ALLARME Si possono avere 2 differenti comportamenti dell uscita di allarme a seconda del valore sommato al par Ab1 0 ALLARME NON RITARDATO L allarme si attiva immediata mente al verificarsi delle condizioni di allarme 2 ALLARME RITARDATO Al verificarsi delle condizioni di allar me viene fatto parti
146. sto U 4 se si desidera che l autotuning OSCILLATORIO venga av viato automaticamente ad ogni modifica del Set di regolazione o al termine del ciclo di Soft Start programmato NOTA L Autotuning di tipo Fast risulta particolarmente rapido e non manifesta alcun effetto sulla regolazione poich calcola i para metri del regolatore durante la fase di raggiungimento del Set Point Per la corretta esecuzione dell autotuning di tipo Fast per ne cessario che all avvio del ciclo vi sia una certa differenza tra la va riabile di processo ed il Set Point per questa ragione lo strumento avvia l autotuning Fast solo quando Per Auto 1 o 2 il valore di processo minore per Func HEAt di SP SP 2 o maggiore per Func CooL di SP SP 2 Per Auto 304 il valore di processo minore per Func HEAt di SP SP 5 o maggiore per Func CooL di SP SP 5 L Autotuning FAST non indicato quando il Set point prossimo alla lettura iniziale o quando la variabile misurata varia in modo irregolare durante il ciclo di sintonizzazione per motivi dovuti al processo la variabile sale o scende In questi casi si consiglia l uso dell Autotuning di tipo oscillatorio il quale attua alcuni cicli di regolazione ON OFF che portano il valore di processo ad oscillare intorno al valore di Set point terminati i quali passa alla regolazione di tipo PID con i parametri calcolati dal
147. t the programming parameters When the protection is activated to be able to gain access to the parameters it will be necessary to type in the programmed password from the ConF menu When the password is required type in using the UP and DOWN keys the number programmed at the PASS parameter and then press the P key If the wrong password is typed in the instrument returns to the regulatory state that it was previously in If the password is correct the display will visualise the code identifying the first group of parameters JSP and with keys UP and DOWN it will be possible to select the desired group of parameters The programming and exit modes for the ConF menu are the same as those described for menu OPEr This protection by password is deactivated by setting the PASS parameter OFF PARAMETER GROUPS PARAMETERS SET PARAMETER Previous Previous Increase A Group A Parameter Value 3 HF HeH nSP i un a pH Er Next er Next D 2se y Next sc Ny Nex yy Decrease Vv Group VI Parameter y Value EXIT PLEASE NOTE If the password is lost turn off the instrument press the P key and turn the instrument back on keeping the key held down for about 5 seconds In this way access is made to all parameters of the ConF menu and it will therefore be possible to check and modify the PASS parameter 2 3 PARAMETERS PROGRAMMING LEVE
148. tata al parametro AL1 per disattivarsi quando scende al di sotto della soglia AL1 HAL1 Con questa modalit possi bile impostare ai par AL1L e AL1H i limiti entro i quali possibile programmare la soglia AL1 TECNOLOGIC spa TLK 31 D ISTRUZIONI PER L USO Vr 01 ISTR MTLK31DITA1 PAG 8 LodE ALLARME RELATIVO DI MINIMA L allarme viene attivato quando il valore di processo scende al di sotto del valore SP AL1 per disattivarsi quando sale al di sopra della soglia SP AL1 HAL 1 Con questa modalit possibile impostare ai par AL1L e AL1H i limiti entro i quali possibile programmare la soglia AL1 HidE ALLARME RELATIVO DI MASSIMA L allarme viene attiva to quando il valore di processo sale al di sopra del valore SP AL1 per disattivarsi quando scende al di sotto della soglia SP AL1 HAL1 Con questa modalit possibile impostare ai par AL1L e AL1H i limiti entro i quali possibile programmare la so glia AL1 HidE LHAb ALLARME ASSOLUTO A FINESTRA L allarme viene atti vato quando il valore di processo scende al di sotto della soglia di allarme impostata al parametro AL1L oppure sale al di sopra del la soglia di allarme impostata al parametro AL1H e si disattiva quando rientra nel campo AL1H HAL1 AL1L HAL 1 LHdE ALLARME RELATIVO A FINESTRA L allarme viene atti vato quando il valore di processo scende al di
149. ten 0 NICHT GESPEICHERTER ALARM Der Alarm bleibt nur im Alarmzustand aktiv 4 GESPEICHERTER ALARM Der Alarm aktiviert sich im Alarmzustand und bleibt auch dann noch bestehen wenn dieser Zustand nicht mehr besteht bis die Taste U gedr ckt wird sofern sie entsprechend programmiert wurde USrb Aac Beispiel mit ABSOLUTER H CHSTWERTALARM ALARMQUITTIERUNG Der Alarmausgang verh lt sich je nach dem im Parameter Ab1 summierten Wert auf 2 verschiedene Arten 0 NICHT QUITTIERBARER ALARM Der Alarm bleibt in einem Alarmzustand stets aktiv 8 QUITTIERBARER ALARM Der Alarm wird in einem Alarmzustand aktiviert und l sst sich anhand der Taste U quittieren sofern diese Taste entsprechend programmiert wurde USrb ASi auch wenn der Alarmzustand weiterhin besteht ALARMVERHALTEN BEI WECHSEL DES SOLLWERT NUR FUR RELATIVER ALARM Man kann 2 verschiedene Verhalten vom Ausgang von Alarm haben nach dem zum Abs addierten Wert Ab1 0 NORMALES VERHALTEN Der Alarm wird bei einem Alarmzustand stets aktiviert 16 ALARMVERHALTEN BEI WECHSEL DES SOLLWERT Wenn das Ger t in den Bedingungen von Alarm dieser nach dem Wechsel des Sollwert ist wird es nicht bet tigt Der Alarm wird nur bet tigen wenn der Wert von Proze nach dem Wechsel des Sets den Bedingungen von nicht Alarm nicht gebracht wird und sp t in die Bedingungen von Alarm AL1i ALARMAKTIVIERUNG BEI MESSFEHLER Hi
150. terwerten entsprechen und die Anwendung richtig funktioniert damit keine St rungen in der Anlage verursacht werden die zu Personen oder Sachsch den f hren k nnten vorgesehenen 3 4 ANSCHLUSSPLAN RELAY 8A AC1 3A AC3 250VAC SSR 10mA 10VDC 13 4181 48 42 po ho De ho Foe ho OUT3 OUT2 OUT1 TLK31 D OUT4 SUPPLY 4 BETRIEB 4 1 MESSUNG UND ANZEIGE Alle Parameter der Messfunktion befinden sich in der Gruppe InP Nachdem eingestellt wurde welche Fuhler verwendet werden sollen k nnen mit dem Parameter Unit die Ma einheit f r die Temperatur C oder F und mit dem Parameter dP die Temperaturaufl sung ausgew hlt werden Wenn der F hler Pr2 nicht verwendet wird muss f r den Parameter Pr 2 die Einstellung Pr 2 no gew hlt werden um zu vermeiden dass eine Fehlermeldung erscheint wenn der F hler nicht angeschlossen ist Das Ger t erm glicht eine Messkalibrierung die je nach Anwendung zur Neueinrichtung des Ger tes verwendet werden kann hierzu werden die Parameter OFS1 OFS2 und rot verwendet Wird der Parameter rot 1 000 gestellt kann im Parameter OFS 1 und oder 2 ein positiver oder negativer Offset eingestellt werden der einfach vor der Anzeige zu dem vom F hler gemessenen Wert hinzuaddiert wird und bei allen Messungen konstant bleibt ISTR MTLK31DDEU2 PAG 4 Soll der eingestellte Offset hingegen nicht bei allen Mess
151. th Func HEAt than SP SP 5 or higher with Func CooL than SP SP 5 4 if it s desired to activate the FAST autotuning automatically to every change of Set Point or at the end of programmed Soft Start cycle The Autotuning will start at the condition that the process value is lower with Func HEAt than SP SP 5 or higher with Func CooL than SP SP 5 1 If OSCILLATORY autotuning should be automatically activated every time the machine is turned on 2 If OSCILLATORY autotuning should be activated automatically the next time the instrument is turned on and once the tuning is finished the Auto OFF parameter is automatically activated 3 If OSCILLATORY autotuning should be activated manually through the U key 4 If OSCILLATORY autotuning should be automatically activated with every modification to the regulation Set or at the end of the Soft Start cycle programmed PLEASE NOTE The Fast type Autotuning is particularly quick and shows no signs of having any effect on the regulation as it calculates the parameters of the regulator during the phase when the Set Point is reached For the correct execution of the Fast type autotuning it is however necessary that at the cycle start up there is a certain difference between the process variable and the Set Point For this reason the instrument only activates the Fast autotuning when For Auto 1 or 2 The process value i
152. thresholds can be modified SAnE Both the active Set Point and the alarm thresholds cannot be modified 2 4 CONTROL STATES The controller can act in 3 different ways automatic control rEG control off OFF and manual control OPLO The instrument is able to pass from one state to the other by selecting the desired state from the main selection menu suing the keyboard By using the key U on the keyboard suitably programming par USrb USrb tunE USrb OPLO USrb OFF it is possible to pass from rEG state to the state programmed on the parameter and vice versa By using the digital input 1 suitably programming par diF diF OFF it is possible to pass from rEG state to the state OFF and vice versa Automatically the instrument swaps into rEG state at the and of the auto tuning execution When switched on the instrument automatically reassumes the state it was in when it was last switched off AUTOMATIC CONTROL rEG Automatic control is the normal functioning state of the controller During automatic control it is possible to visualize the control power on the display by pushing key UP The range of the power values goes from H100 100 of the output power with reverse action to C100 100 of the output power with direct action CONTROL OFF OFF The instrument can be swapped into the OFF state i e the control and the relative o
153. tivare Autotuning o Selftuning Mettere lo strumento in regolazione manuale Tacitare l allarme Cambiare il Set Point attivo Disattivare la regolazione 5 Led OUT1 Indica lo stato dell uscita OUT1 6 Led OUT 2 Indica lo stato dell uscita OUT2 7 Led OUT 3 Indica lo stato dell uscita OUT3 8 Led OUTA Indica lo stato dell uscita OUT4 9 Led SET Lampeggiando indica l ingresso nella modalit di programmazione 10 Led AT ST Indica la funzione Selftuning inserita acceso o Autotuning in corso lampeggiante 11 Led Indice di scostamento Indica che il valore di processo inferiore rispetto al Set del valore impostato al par AdE 12 Led Indice di scostamento Indica che il valore di processo all interno del campo SP AdE SP AdE 13 Led indice di scostamento Indica che il valore di processo superiore rispetto al Set del valore impostato al par AdE 2 PROGRAMMAZIONE 2 1 IMPOSTAZIONE RAPIDA DEI SET POINT Questa procedura permette di impostare in modo veloce il Set Point attivo ed eventualmente le soglie di allarme vedi par 2 3 Premere il tasto P quindi rilasciarlo e il display visualizzer SP n dove n il numero del Set Point attivo in quel momento alternato al valore impostato Per modificarlo agire sui tasti UP per incrementare il valore o DOWN per decrementarlo Questi tasti agiscono a passi di un digit ma se mantenuti premuti oltre un secondo il valore si in
154. tput s Up to 4 outputs 2 SPDT and 2 SPST NO 8 A AC1 3 A AC3 250 VAC or in tension to drive SSR 10mA 10VDC Electrical life for relay outputs 100000 operat Installation category Il Measurement category Protection class against electric shock Class II for Front panel Insulation Reinforced insulation between the low voltage section relay outputs and the front panel Reinforced insulation between the low voltage section relay outputs and the extra low voltage section inputs SSR outputs No insulation between supply inputs and SSR outputs 50 V insulation between RS485 and extra low voltage section 2 MECHANICAL DATA Housing Self extinguishing plastic UL 94 VO Dimensions 78 x 35 mm depth 64 mm Weight 150 g approx Mounting Flush in panel in 71 x 29 mm hole Connections 2 5 mm screw terminals block Degree of front panel protection IP 65 mounted in panel with gasket Pollution situation 2 Operating temperature 0 50 C Operating humidity 30 95 RH without condensation Storage temperature 10 60 C min 12 mm RECOMMENDED 7 PANEL CUTOUT jj wd 4 DOO ss TIO MAX 12 mm PANEL GASKET 7 4 FUNCTIONAL FEATURES Control ON OFF Neutral zon single and double acti
155. tuning function OPLO to swap the regulator to the manual control state ni and therefore to program the control value using the UP and DOWN keys Once the desired item has been selected push key P to confirm Selecting OPEr and ConF gives the possibility of accessing other menus containing additional parameters and more precisely OPEr Operating parameters Menu this normally contains the Set Point parameters but it can contain all the desired parameters see par 2 3 ConF Configuration parameters Menu this contains all the operating parameters and the functioning configuration parameters alarm configuration control input etc A re 1 EG iP eaeg Hold for 2 sec on OFF Fo Peer 4 ay AUTOTUNING ToT t SELFTUNING Eun RHP Bea Y Vv Li gt OPLO POPLO T To enter the menu OPEr select the option OPEr and press the key P The display will now show the code identifying the first group of parameters ISP and by pressing the UP and DOWN keys it will be possible to select the group of parameters to be modified Once the desired group of parameters has been selected the cod
156. ty levels or dirt that may create condensation or introduction of conductive substances into the instrument Ensure adequate ventilation to the instrument and avoid installation in containers that house devices which may overheat or which may cause the instrument to function at a higher temperature than the one permitted and declared Connect the instrument as far away as possible from sources of electromagnetic disturbances such as motors power relays relays solenoid valves etc 3 3 ELECTRICAL CONNECTION Carry out the electrical wiring by connecting only one wire to each terminal according to the following diagram checking that the power supply is the same as that indicated on the instrument and that the load current absorption is no higher than the maximum electricity current permitted As the instrument is built in equipment with permanent connection inside housing it is not equipped with either switches or internal devices to protect against overload of current the installation will include a two phase circuit breaker placed as near as possible to the instrument and located in a position that can easily be reached by the user and marked as instrument disconnecting device which interrupts the power supply to the equipment It is also recommended that all the electrical circuits connected to the instrument must be protect properly using devices ex fuses proportionate to the circulating currents It is strongly recommended that cables
157. typically on a personal computer used as plant supervisor Using a personal computer it is possible to acquire all the function information and to program all the instruments configuration parameters The software protocol adopted for TLK31D is a MODBUS RTU type widely used in several PLC and supervision programs available on the market TLK series protocol manual is available on request The interface circuit allows the connection of up to 32 instruments on the same line To maintain the line in rest conditions a 120 Ohm resistance Rt must be connected to the end of the line The instrument is equipped with two terminals called A and B which have to be connected with all the namesake terminals of the net For the wiring operation they must be interlaced with a double cable telephonic type Nevertheless particularly when the net results very long or noised it is advisable to adopt a screened cable wired as in the drawing If the instrument is equipped with a serial interface the parameters to be programmed are the following all present in the parameters group ISEr Add Address of the station Set a different number for each station from 1 to 255 baud Transmission speed baud rate programmable from 1200 to 38400 baud All the stations have to have the same transmission speed PACS Programming access If programmed as LoCL this means that the instrument is only programmable from the keyboard if programmed as
158. ungen konstant bleiben kann die Kalibrierung an zwei beliebigen Punkten vorgenommen werden In diesem Fall sind zur Bestimmung der in den Parametern OFS und rot einzugebenden Werte die folgenden Formeln zu verwenden rot D2 D1 M2 M1 OFS D2 rot x M2 Hierbei ist M1 der gemessene Wert 1 D1 der anzuzeigende Wert wenn das Ger t M1 misst M2 der gemessene Wert 2 D2 der anzuzeigende Wert wenn das Ger t M2 misst Daraus ergibt sich f r das Ger t die folgende Anzeige DV MV x rot OFS Hierbei ist DV der angezeigte Wert MV der gemessene Wert Beispiel Das Ger t soll bei 20 den tats chlich gemessenen Wert anzeigen und bei 100 einen um 10 niedrigeren Wert 90 Daraus ergibt sich M1 20 D1 20 M2 100 D2 90 rot 90 20 100 20 0 875 OFS 90 0 875 x 100 2 5 Im Parameter FiL kann die Zeitkonstante des Softwarefilters der Messung des Eingangswertes derart eingestellt werden dass die Empfindlichkeit gegen Messst rungen reduziert wird Zeit wird erh ht Bei Messfehlern sorgt das Ger t daf r dass am Ausgang die im Parameter OPE eingegebene Leistung abgegeben wird Diese Leistung wird nach der f r den PID Regler programmierten Zykluszeit berechnet w hrend f r die EIN AUS Regler automatisch eine Zykluszeit von 20 Sekunden angenommen wird z B bei F hlerfehler und EIN AUS Regelung und OPE
159. utotuning nei parametri relativi alla regolazione PID Per attivare la funzione di SELFTUNING procedere come segue 1 Impostare ed attivare il Set point desiderato 2 Impostare il parametro Cont Pid oppure 3 Pt se lo stru mento comanda un azionamento motorizzato a posizionamento temporale 3 Se il controllo a singola azione impostare il parametro Func in funzione del processo da controllare attraverso l uscita 1 rEG 4 Configurare un uscita come 2 rEG se lo strumento comanda un impianto con doppia azione o un azionamento motorizzato a posi zionamento temporale 5 Impostare il parametro SELF yES 6 Uscire dalla programmazione parametri 7 Collegare lo strumento all impianto comandato 8 Attivare il Selftuning mediante la selezione della voce tunE nel men principale o mediante il tasto U opportunamente programmato Quando la funzione di Selftuning attiva il led AT ST si accende in modo fisso e tutti i parametri di regolazione PID Pb Int dEr ecc non vengono pi visualizzati Per interrompere il ciclo di Autotuning o disattivare il Selftuning se lezionare dal men SEL uno qualsiasi degli stati di regolazione rEG OPLO o OFF Se lo strumento viene spento durante l autotuning o con la funzione di Selftuning attivata alla sua riaccensione le funzioni risulteranno inserite 4 9 VARIAZIONE DINAMICA DEL SET POINT E COMMUTAZIO NE AUTOMATICA TRA DUE SET POINT RAMPE E TEMPO
160. utputs are deactivated The alarm outputs are instead working normally BUMPLESS MANUAL CONTROL OPLO By means of this option it is possible to manually program the power percentage given as output by the controller by deactivating automatic control When the instrument is swapped to manual control the power percentage is the same as the last one supplied and can be modified using the UP and DOWN keys As in the case of automatic control the programmable values range from H100 100 to C100 100 To return to automatic control select rEG in the selection menu 2 5 ACTIVE SET POINT SELECTION This instrument permits pre programming of up to 4 different Set points SP1 SP2 SP3 SP4 and then selection of which one must be active The maximum number of Set points is determined by the par nSP located in the group of parameters JSP The active Set point can be selected by parameter SPAt in the group of parameters JSP by key U if par USrb CHSP by the digital inputs if diF CHSP SP1 2 SP1 4 or HE Co Automatically between SP1 and SP2 if a time dur t see par 4 8 has been programmed Set Points SP1 SP2 SP3 SP4 will be visible depending on the maximum number of Set Points selected on par nSP and they can be programmed with a value that is between the value programmed on par SPLL and the one p
161. vi massima 28 AL1 Soglia allarme AL1 AL1L ALIH 0 51 HAL3 Isteresi allarme AL3 OFF 9999 1 29 AL1L Soglia inferiore allarme 1999 AL1H 1999 52 AL3d Ritardo attivazione al OFF 9999 OFF AL1 a finestra o limite larme AL3 sec inferiore del set AL1 per 53 AL3i Attivazione allarme AL3 no yES no allarmi di minima o in caso di errore di massima misura 30 AL1H Soglia inferiore allarme AL1L 9999 9999 Gruppo LbA parametri relativi al Loop Break Alarm AL1 a finestra o limite Par Descrizione Range Def Note DIEBE Aube 54 OLbA Uscita destinata allal Out Out2 OFF alarmie di aminima ci larme LbA Out3 Out4 esta AL1 OFF 9999 1 SE 31 HAL1 Isteresi allarme i 32 AL1d Ritardo attivazione al OFF 9999 OFF DE PEA E ESSER larme AL1 sec z PRE F 33 AL1i Attivazione allarme AL1 no yES no gruppe das paramet relativi le a Def Note Da 56 Cont Tipo di regolazione Pid On FA Pid misura Tp Pid PID On FS nr Gruppo AL2 parametri relativi all allarme AL2 On FA ON OFF asim f Par Descrizione Range Def Note On FS ON OFF simm 34 OAL2 Uscita destinata allal Out1 Out2 OFF nr ON OFF a Zona larme AL2 Out3 Out4 Neutra OEE 57 Func Modo di funzionamento HEAt CooL HEAt 35 PrA2 Valore di processo per Pri Pr2 Pri uscita 1 rEG allarme AL2 P1 2 HEAt Riscaldamento 36 AL2t Tipo allarme AL2 LoAb HiAb LoAb CooL Raffreddamento vedi AL1t LHAb LodE
162. wird aktiviert wenn die Ausgangsleistung w hrend der im Parameter LbAt eingegebenen Zeit angegeben in Sekunden beim Wert von 100 bleibt Zur Vermeidung von Fehlalarmen muss der Einstellwert dieses Parameters unter Ber cksichtigung der Zeit zum Erreichen des Sollwertes eingegeben werden wenn der gemessene Wert stark hiervon abweicht z B bei Einschaltung der Anlage Bei Ansprechen des Alarms erscheint auf der Ger teanzeige die Meldung LbA und das Ger t verh lt sich wie bei einem Messfehler wobei am Ausgang die im Parameter OPE programmierbar in der Gruppe InP eingestellte Leistung abgegeben wird Zur Wiederherstellung des normalen Betriebs nach einem Alarm ist die Regelart OFF anzuw hlen und schlie lich der automatische Regelbetrieb rEG zu aktivieren nachdem der F hler und der Verbraucher auf ihre einwandfreie Funktionst chtigkeit berpr ft wurden Zur Deaktivierung des Loop Break Alarms ist lediglich OLbA OFF zu programmieren 4 13 FUNKTION DER TASTE U Die Funktion der Taste U kann im Parameter USrb der Gruppe IPAn bestimmt werden Folgende Einstellungen sind f r diesen Parameter m glich noF Keine Funktionsbelegung der Taste tunE Wird die Taste mindestens 1 Sekunde lang gedr ckt kann das Autotuning oder Selftuning aktiviert deaktiviert werden OPLO Wird die Taste mindestens 1 Sekunde lang gedr ckt kann zum automatischen Regelbetrieb rEG o
163. with proper insulation according to the working voltages and temperatures be used Furthermore the input cable of the probe has to be kept separate from line voltage wiring If the input cable of the probe is screened it has to be connected to the ground with only one side For the electrical supply of the instrument it s recommended to use an external transformer TCTR or with equivalent features and to use only one transformer for each instrument because there is no insulation between supply and input We recommend that a check should be made that the parameters are those desired and that the application functions correctly before connecting the outputs to the actuators so as to avoid malfunctioning that may cause irregularities in the plant that could cause damage to people things or animals 3 4 ELECTRICAL WIRING DIAGRAM RELAY 8A AC1 3A AC3 250VAC SSR 10mA 10VDC 13 4181 48 42 E io ho Foro ho Ere fo OUT4 OUT3 OUT2 OUT1 TLK31 D SUPPLY 4 FUNCTIONS 4 1 MEASURING AND VISUALIZATION All the parameters referring measurements are contained in the group InP TECNOLOGIC spa TLK 31 D OPERATING INSTRUCTIONS Vr 02 Using par SEnS it s possible to select the type of input probe which can be thermistors PTC KTY81 121 Ptc or NTC 103AT 2 ntc We recommend to switch on and off the instrument when these parameters are modified in order to obtain a correct measuring Once the type of probe ha

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation - Thermo-hygro  Conditions générales Web    CAFETERA COFFEEMAKER CAFETEIRA  Bighorn Safe 7144ELX Instructions / Assembly  QB-V850MINI, QB-V850MINIL On-Chip Debug Emulator User`s  Dell 857-10569 Computer Monitor User Manual  Spektrum SPMSR410  Le secrétaire li`Etat à la France d`attire-mer,  Service Manual, UBK 815 Bicycle.fm  