Ideal Industries 61-736

image

Contents

1. CORRECT Use with line splitter DC Voltage Page 6 Measuring Resistance Ohms e Verify the circuit is de energized to obtain accurate measurements Verifying Continuity 1 e Verify the circuit is de energized e The meter will sense the level of resistance and beep if the resistance is less than 25 Q to confirm that continuity is present Page 7 Open Circuit Battery Replacement f e Ensure test leads are disconnected from circuit or components e Remove test leads from input jacks on meter e Remove the two screws from the battery cap e Remove the battery cap e Replace batteries with two AAA batteries e Assemble the battery cap to the meter and re tighten the screws Maintenance e Clean the case with a damp cloth and mild detergent Do not use abrasives or solvents Service and Replacement Parts This unit has no user serviceable parts For replacement parts or to inquire about service information contact IDEAL INDUSTRIES INC at 1 877 201 9005 or visit our website www testersandmeters com Page 8 Specifications Display Polarity Overrange Measure Rate Auto Power Off Battery Life Low Battery Indication Power Supply Accuracy Temperature Coefficient Altitude Operating Environment Storage Environment Jaw Opening Dimensions Weight Accessories included Safety
2. 400 AAC Clamp Meter Instruction Manual CLAMP CAT III 61 732 61 736 WARNING A Read First Safety Information Understand and follow operating instructions carefully Use the meter only as specified in this manual otherwise the protection provided by the meter may be impaired AN WARNING To avoid possible electric shock personal injury or death follow these guidelines e Do not use if meter appears damaged Visually inspect the meter to ensure case is not cracked and back case is securely in place e Inspect and replace leads if insulation is damaged metal is exposed or probes are cracked Pay particular attention to the insulation surrounding the connectors e Do not use meter if it operates abnormally as protection maybe impaired e Do not use during electrical storms or in wet weather e Do not use around explosive gas dust or vapor e Do not apply more than the rated voltage to the meter e Do not use without the battery and the back case properly installed e Remove the test leads from the circuit prior to removing battery cap e Do not attempt to repair this unit as it has no user serviceable parts TRANSAT gt visitus at ranscatcom 35 Vantage Point Drive Rochester NY 14624 Call 1 800 800 5001 Page 2 CAUTION To protect yourself think Safety First e Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution e Use appropriate personal protect
3. e No utilice el medidor si funciona de forma anormal ya que la protecci n puede haberse da ado e No lo utilice durante tormentas el ctricas o con tiempo h medo e No lo utilice cerca de gases polvo o vapores explosivos e No aplique al medidor un voltaje mayor que el voltaje nominal e No lo utilice sin las bater as y sin la caja posterior bien instalada e Quite los cables de prueba del circuito antes de quitar la tapa de las bater as e No intente reparar esta unidad ya que no tiene piezas reparables por el usuario Page 2 PRECAUCI N Para protegerse piense en la Seguridad ante todo e Los voltajes que superen 30 V CA o 60 V CC presentan un peligro de descarga por lo que debe tener cuidado e Utilice equipos de protecci n personal apropiados como gafas de seguridad m scaras guantes aislantes botas aislantes y esteras aislantes e Antes de cada uso Realice una prueba de continuidad poniendo en contacto los cables de prueba entre s para verificar la funcionalidad de las bater as y los cables de prueba Use el M todo de Seguridad de 3 Puntos 1 Verifique la operaci n del medidor midiendo un voltaje conocido 2 Aplique el medidor al circuito bajo prueba 3 Pruebe nuevamente con un voltaje real conocido para asegurar un funcionamiento correcto e Nunca se conecte a tierra cuando tome medidas el ctricas e Conecte el cable com n negro a tierra antes de aplicar el cable de prueba rojo
4. o Double Insulation 3 3 4 digit LCD with 4000 counts Automatic positive implied negative polarity indication OL indication is displayed Samples 2 times pe Approximately after 400 hours continuo 250 hours continuo second nominal 10 minutes of non us with Alkaline 61 us with Alkaline 61 USE 732 736 The is displayed when battery voltage drops below operating level 2 1 5V AAA batteries NEDA R03 Includes an isolated battery compartment Stated accuracy at 23 C 5 C lt 75 RH 0 1 x specified accuracy per C 0 C to 18 C 28 C to 50 C 6561 7 ft 2000m 32 F to 122 F 0 C to 50 C at lt 70 R H 4 F to 140 F 20 C to 60 C at lt 80 RH Accepts a 1 25 32mm conductor 7 4 H x2 6 W x1 5 D 187mm H x65mm W x37mm D 6 7 oz 1909 including batteries Carrying Case Test Leads 2 1 5V AAA batteries operating instructions Complies with EN 61010 1 EN 61010 2 032 UL 61010B 1 UL 61010B 2 032 specifications Clamp rated to Cat IIl 300V Voltage rated for Cat IIl 600V Dus C ie Instrument has been evaluated and complies with insulation category III overvoltage category Ill Pollution degree 2 in accordance with IEC 644 Indoor use Page 9 Ranges amp Accuracies AC Converter 61 732 model is averaging sensing rms calibrated 61 736 model is true rms sensing Accuracy Accuracy is specified as a percentage of the rea
5. unreasonable use of the instrument Manual de Instrucciones Any implied warranties arising out of the sale of an IDEAL product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the above The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss State laws vary so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Page 11 ADVERTENCIA A Lea primero Informaci n de seguridad Comprenda y siga estas instrucciones de operaci n cuidadosamente Use el medidor s lo seg n se especifica en este manual de lo contrario la protecci n que l proporciona podr a deteriorarse AN ADVERTENCIA Para evitar una posible descarga el ctrica lesiones personales o la muerte siga estas instrucciones e No utilice el medidor si se lo ve da ado Inspeccione visualmente el medidor para asegurarse de que la caja no est agrietada y la caja posterior est colocada firmemente e Inspeccione y reemplace los cables si el aislamiento est da ado el metal est al descubierto o las sondas est n agrietadas Preste atenci n en particular al aislamiento que rodea los conectores
6. Display Icons 11 4000 count display 12 Units of measure 13 Voltage 14 Amperes 15 Ohms 16 Continuity 17 AC measurement is selected 18 DC measurement is selected 19 Polarity indicator for DC 21 22 23 16 20 Low battery indicator L d a L 21 Range 17 ac 22 Data hold Fu BE 10 A 23 APO Auto Power Off ho m VA i4 Symbols on the Unit 2 n e A Warning read the instruction manual 12 e NCV Non Contact Voltage e Cat Ill 600V Safety category 15 Page 4 OPERATION Non contact voltage NCV With the NCV tab on the tip of the clamp close to an AC voltage press the NCV but ton The NCV LED will light and the beeper will sound The closer the NCV tab is to AC voltage the louder the beep To differentiate between hot and neutral in an outlet insert the NCV tab into each slot in the outlet The beeper will be much louder on the hot side of the outlet than the neutral The test lead can also be used to differen tiate between the hot and neutral Plug the red test lead into the V 2 input jack on the meter Press the NCV button and insert the probe tip into each slot of the outlet The beeper will only beep on the hot side of the outlet Auto Manual Ranging Mode The meter defaults to autoranging mode when powered on In this mode the meter automatically selects the best range to display the measurement By pressing the Range Ce button on the meter the manual range mod
7. connect s du circuit ou des composants e Retirer les fils d essai des prises d entr e du multim tre e Retirer les deux vis du capuchon de piles e Retirer le capuchon de piles e Remplacer les piles par deux piles AAA e Monter le capuchon des piles sur le multim tre et resserrer les vis Entretien e Nettoyer le bo tier avec un chiffon humide et un d tergent doux N utiliser ni abrasifs ni solvants Entretien d pannage et pi ces de rechange Cet appareil ne comporte pas de pi ces r parables par l utilisateur En se ce qui concerne les pi ces de rechange ou les renseignements concernant l entretien d pannage se mettre en rapport avec IDEAL INDUSTRIES INC Au 1 877 201 9005 ou visitez notre site web www testersandmeters com Page 20 Fiche technique Affichage Polarit D passement Fr quence de mesure Arr t automatique Dur e de service de la pile T moin de d charge de piles Alimentation Pr cision Coefficient de temp rature Altitude Environnement op rationnel Environnement de stockage Ouverture de la m choire Dimensions Poids S curit Accessoires Inclus Affichage cristaux liquides 3 3 4 chiffres avec d compte jusqu 4000 Indication de polarit automatique positif implicite n gatif L indication OL est affich e 2 chantillonnages par minute nominal Au bout de 10 minutes de non utilisation 400 heures
8. isolant est endommag le m tal expos ou les sondes fendues Porter une attention particuli re l isolant entourant les connecteurs e Ne pas utiliser le multim tre s il fonctionne de mani re anormale la protection qu il offre pouvant tre compromise e Ne pas utiliser par temps orageux ou dans la pluie e Ne pas utiliser proximit de gaz de poussi re ou de vapeurs explosifs e Ne pas soumettre le multim tre une tension sup rieure la tension nomi nale e Ne pas utiliser sans la pile ou si l arri re du bo tier n est pas bien mont e Retirer les fils d essai du circuit avant de retirer le capuchon de pile e Ne pas tenter de r parer cet appareil ll ne comporte aucune pi ce r parable par l utilisateur Page 14 ATTENTION Afin d assurer sa propre protection penser S curit avant tout e Les tensions sup rieures 30 V c a ou 60 V c c posent un risque d lectrocu tion faire donc preuve de prudence e Utiliser du mat riel de protection ad quat tels que des lunettes des crans faciaux des gants isolants des bottes isolantes et ou des tapis isolants e Avant chaque utilisation Proc der un essai de continuit et mettant les fils d essai en contact l un avec l autre afin de contr ler le fonctionnement de la pile et des fils d essai Utiliser la m thode de s curit en 3 points 1 V rifier le fonctionnement du multim tre en mesurant une tension connue 2
9. Appliquer le multim tre au circuit en cours de contr le 3 Re tester ensuite sur la tension active connue pour v rifier le bon fonctionnement e Ne jamais se mettre la terre quand on proc de des mesures lectriques e Connecter le conducteur commun noir la terre avant d appliquer le conduc teur d essai rouge sur la tension Commencer par d connecter le conducteur d essai rouge de la tension e Travailler toujours avec un quipier e Quand on se sert les sondes tenir les doigts aussi loin que possible des pointes de sonde Caract ristiques e Multim tre pince s lection de plages automatique manuelle e Valeurs efficaces r elles mod le 61 736 seulement e D tection de tension sans contact 70 600 V c a e Mesure le courant de 400 A c a e Mesure la tension c a c c et la r sistance e Continuit audible e R tention de donn es e Arr t automatique e Indicateur d puisement de piles e M choires de faible encombrement permettant de travailler dans des espaces restreints e Protection lectronique contre la surcharge sur toutes les plages Page 15 Caract ristiques Pince m choire Levier Cadran des fonctions Affichage cristaux liquides Terminal d entr e tension et r sistance V Q Terminal d entr e commun COM D tection de tension sans contact NCV 8 Plage 9 R tention de donn es 10 Fonctions de mesure No Ic nes d affichage 11 Affichage jusqu
10. Auto Power 19 rey rr m Off APO 18 foo KMQmVA 14 Simbolos de la unidad gt e A Advertencia lea el manual de 0 13 instrucciones 7 e NCV Non Contact Voltage Voltaje sin contacto 15 e Cat Ill Categor a de seguridad 600 V Page 4 OPERACION Voltaje sin contacto Non Contact Voltage NCV Manteniendo la leng eta NCV de la punta de la pinza cerca de un voltaje de CA pre sione el bot n NCV El LED NCV se encender y el emisor de pitidos sonar Cuanto m s se aproxime la leng eta NCV al voltaje de CA m s fuerte ser el pitido Para distinguir entre el vivo y el neutro de un tomacorriente introduzca la leng eta NCV en cada una de sus ranuras El pitido ser mucho m s fuerte en el lado vivo del omacorriente que en el neutro El cable de prueba puede utilizarse tambi n para dis tinguir entre el vivo y el neutro Enchufe el cable de prueba rojo en la entrada Ve Presione el bot n NCV e inserte la punta de la sonda en cada ranura del tomacorri nte El emisor de pitidos sonar nicamente en el lado vivo del tomacorriente cD Modo de selecci n de gama autom tico manual El medidor al encenderse va por defecto al modo de selecci n autom tica de gama En este modo el medidor selecciona autom ticamente la mejor gama para indicar la medida Al presionar el bot n Range Gama e del medidor el modo de selecci n manual de gama prevalecer sobre la func
11. automatiquement au bout de 10 minutes s il n est pas util is Appuyer sur n importe quel bouton le multim tre s allume automatiquement et affiche la derni re lecture relev e On peut neutraliser cette fonction en appuyant sur le bouton Range tout en tournant le bouton des fonctions de la position d arr t Off nimporte quelle autre position Quand APO est neutral is APO dispara t de l affichage Quand on teint le multim tre on restaure PAPO coupure automatique implicite Mesure du courant C A Amp res CORRECT INCORRECT CORRECT Conducteur Les courants Utilisation unique s annulent avec r parti seulement tion de ligne Page 18 Mesure de la tension oF Ee pa EA of Tension c a Tension c c Mesure de la r sistance Ohms e V rifier que le circuit est d sexcit pour obtenir des mesures pr cises Page 19 V rification de la continuit e V rifier que le circuit est d sexcit e Le multim tre d tectera le niveau de r sistance et mettra un signal sonore si la r sistance est inf rieure 25Q pour confirmer la pr sence d une continuit Circuit ENTRETIEN tenn Remplacement de la pile e S assurer que les fils d essai sont d
12. d utilisation en continu avec une pile alcaline 61 732 250 heures d utilisation en continu avec une pile alcaline 61 736 Le P gt est affich quand la tension de la pile tombe au dessous du niveau op rationnel 2 pilles AAA de 1 5 V NEDA R03 Comprend un logement de piles isol Pr cision nominale 23 C 5 C lt 75 H R 0 1 x pr cision sp cifi e par C 0 C 18 C 28 C 50 C 6561 7 pi 2000 m 32 F 122 F 0 C 50 C lt 70 d HR 4 F 140 F 20 C 60 C lt 80 d HR Accepte un fil de 1 25 po 32 mm 7 4 po L x 2 6 pol x 1 5 po H 187 mm L x 65 mm x 37 mm H 6 7 oz 190 g piles y compris Conforme aux normes EN 61010 1 EN61010 2 032 UL61010B 1 UL61010B 2 032 pince conforme a Cat 111 300 V Tension nominale Cat IlI 600V Etui de transport fils d essais 9 0 piles AAA de 1 5 V mode d emploi Dus C Page 21 a Double isolation Pr cision Protection 7 il t A at j Annria d i i nnri Plage et contre L appareil a t valu et il est conforme la cat gorie d isolation Ill cat gorie de ee a E i surcharge surtension Ill Degr de pollution 2 conforme la norme IEC 644 Pour une util a isation l int rieur Courant 2 A 400 0A 50Hz 60Hz 1 7 6 chiffres 1 7 10 chiffres ane C a 40 00 A 400 0A 60Hz 400Hz 3 0 6 chiffres 3 0 10 chiffres Plages et pr cisions 40
13. de funciones desde la posici n OFF APAGADO hasta cualquier otra Cuando se anula el apagado autom tico la leyenda APO desaparecer de la pantalla Al apagar el medidor se restaurar la caracter stica de apagado autom tico por defecto Medida de corriente alterna CA amperes CORRECTO INCORRECTO CORRECTO S lo un Las corrientes Uso con divi conductor se anulan sor de l nea nico Page 6 Medida de voltaje Fa Vy 7 j VI dr I OT 15 C7 gt gt _ lt ff 77 da O a LL Voltaje de CA Voltaje de CC Medida de resistencia ohms e Para obtener medidas precisas verifique que el circuito est desenergizado Page 7 Verificaci n de continuidad 1 e Verifique que el circuito est desenergizado e El medidor detectar el nivel de resistencia y emitir un pitido si la resistencia es menor que 25 Q para confirmar que existe continuidad Circuito Circuito cerrado interrumpido MANTENIMIENTO Reemplazo de las bater as e Aseg rese de que los cables de prueba est n desconectados del circuito o de los componentes e Retire los cables de prueba de los conectores hembra jacks de entrada del medidor e Quite los dos tornillos de la tapa de las bater as e Retire l
14. especificada por C 0 C a 18 C temperatura 28 C a 50 C Altitud 2000 m 6561 7 pies Ambiente de operaci n 0 C a 50 C 32 F a 122 F humedad relativa lt 70 Ambiente de 20 C a 60 C 4 F a 140 F humedad relativa lt 80 almacenamiento Abertura de la mordaza Acepta un conductor de 32 mm 1 25 Dimensiones 187 mm altura x 65 mm ancho x 37 mm prof 7 4 altura x 2 6 ancho x 1 5 prof Peso 190 g 6 7 onzas incluyendo bater as Accesorios incluidos Estuche port til Cables de prueba 2 bater as AAA de 1 5 instrucciones de operaci n Seguridad Cumple con las especificaciones EN 61010 1 EN 61010 2 032 UL 61010B 1 UL 61010B 2 032 especificaci n de la pinza Cat IIl 300V Especificaci n de voltaje Cat III 600V Mus C 2 Page 9 E Aislamiento doble Gama y Precisi n Protecci n contra El instrumento ha sido evaluado y cumple con la categor a III de aislamiento Funci n resoluci n 61 732 61 736 sobrecarga categorfa III de sobrevoltaje Grado 2 de contaminaci n de acuerdo con IEC Corriente 40 00 A 400 0 A 50Hz 60Hz 11 7 6 d gitos 1 79 10 d gitos 644 Uso en interiores aa 400A CA alterna CA 40 00 A 400 0 A 60Hz 400Hz 3 0 6 digitos8 0 10 d gitos Gamas y precisiones 400 0V 50Hz 500H2 1 2 5 digitos 1 2 8 d gitos ae N 600V 1 5 5 digitos 1 5 8 digit P 50Hz 500Hz 1 9 5 digitos 1
15. 0 0V 50Hz 500Hz 1 2 5 chiffres 1 2 8 chiffres Tension E 600 V c a c c Convertisseur c a a 600V 50Hz 500Hz 1 5 5 chiffres 1 5 8 chiffres Le mod le 61 732 assure une detection par calcul de moyenne le modele 61 jon c c 400 0V 600V 05 2 chi 736 talonn avec des valeurs efficaces r elles assure une v ritable d tection 400 0 4 000k2 40 00k0 1 0 4 chi 600 V c a c c avec des valeurs efficaces r elles 400 0k Q R sistance Zn oe 4 i Pr cision aoe aed 600 V calc La pr cision est sp cifi e sous la forme d un pourcentage de la lecture une ue SIERO quantit fixe 23 C 5 C 73 49 9 F moins de 75 d humidit relative Audible indication lt 250 Continuit Non sp cifi 600 V c a c c Response time 500ms Coefficient de temp rature 0 1 fois la sp cification de pr cision applicable par degr C de 0 C 18 C et 28 C 50 C 32 F 64 F et 82 F 122 F Remarque La protection contre la surcharge est exprim e en tension maxi efficace r elle Page 22 Page 23 Garantie Ce multim tre est garanti l acheteur primitif contre tout vice de mati re ou de fa on pour toute la vie utile dudit produit Pendant la p riode de garantie IDEAL INDUSTRIES INC remplacera ou r parera selon son choix l appareil d fectueux sous r serve de v rification du vice ou de l anomalie Cette garantie ne s appliqu
16. 4000 12 Unit s de mesure 13 Tension 14 Amp res 15 Ohms 16 Continuit 17 Mesure de c a est s lectionn e 18 Mesure de c c est s lectionn e 19 T moin de polarit pour c c 20 T moin de d charge de la pile 21 22 23 16 2 Ai a 5 3 L R tention de donn es HOLD APO n 23 Arr t automatique de l alimentation 1h MMT AAA 18 Li LI LT KM QmVA 14 Symboles figurant sur l appareil I e A Avertissement lire le mode 20 13 d emploi 12 e D tection de tension sans contact NCV e Cat Ill Cat gorie de s curit 600 V 15 Page 16 FONCTIONNEMENT D tection de tension sans contact TSC En veillant ce que l onglet NCV du bout de la pince soit pr s d une tension c a appuyer sur le bouton NCV La DEL NCV s allumera et l avertisseur sonore se d clenchera Plus le capteur NCV est proche de la tension alternative et plus le bip est fort Pour diff rencier le fil sous tension du fil neutre dans une prise introduire l onglet NCV dans chaque fente de la prise Le bip sera plus fort du c t sous tension que du c t neutre de la prise Le fil d essai rouge peut gale ment tre utilis pour diff rencier le fil sous tension du fil neutre Mettre le fil d essai rouge dans l entr e VO Appuyer sur le bouton NCV et introduire la pointe de la sonde dans chacun des trous de la prise Lavertisseur sonore ne se d clenchera que du c t sous tension de la prise S lec
17. 5 8 d gitos Convertidor de CA i El modelo 61 732 detecta valores promedio y esta calibrado en valores eficaces Voltaje de CC 400 0V 600V 0 5 2 d gitos rms 600 V CA CC rms 400 082 4 000k22 40 00k2 se El modelo 61 736 detecta valores eficaces rms reales 400 0k Q 1 0 4 d gitos Resistencia Precision 4 000MQ 1 5 4 digitos 600 V CA CC rms La precisi n se especifica como un porcentaje de la lectura una cantidad 40 00MQ 3 0 5 digitos r o o o o H O fija a 23 C 5 C 73 4 F 9 F y una humedad relativa menor que 75 Ea Sin especificaci n 600 V CA CC rms Coeficiente de temperatura 0 1 veces la especificaci n aplicable de Response time 500ms precisi n por grado C desde 0 C hasta 18 C y desde 28 C hasta 50 C 32 F a 64 F y 82 a 122 F Nota Protecci n contra sobrecarga especificada como el m ximo voltaje eficaz rms Page 10 Page 11 Garantia Se garantiza al comprador original del medidor contra los defectos de material y mano de obra durante la vida til del producto Durante este per odo de garant a IDEAL INDUSTRIES INC podr a su elecci n reemplazar o reparar la unidad defectuosa S ujeta a verificaci n del defecto o falla Esta garant a no se aplica a defectos resultantes del mal uso negligencia accidente reparaci n no autorizada a Cualquier ga teraci n o uso irracional de este instrumento ant a impl ci
18. a tapa de las bater as e Reemplace las bater as por dos bater as AAA e Monte la tapa de las bater as en el medidor y vuelva a apretar los tornillos Mantenimiento e Limpie la caja con un trapo humedecido y detergente suave No use abrasivos ni disolventes Piezas de servicio y de repuesto Esta unidad no contiene piezas reparables por el usuario Si necesita piezas de repuesto o averiguar sobre informaci n de servicio contacte con IDEAL INDUSTRIES INC llamando al 1 877 201 9005 o visite nuestro sitio Web www testersandmeters com Page 8 Especificaciones Pantalla Pantalla de cristal l quido LCD de 3 3 4 d gitos 4000 cuentas Polaridad Autom tica positiva impl cita indicaci n de polaridad negativa Fuera de gama Se indica en la pantalla OL Frecuencia de medici n 2 muestras por segundo nominal Apagado autom tico Despu s de aproximadamente 10 minutos sin uso Auto Power Off APO Vida de las bater as 400 horas continuas con bater as alcalinas 61 732 250 horas continuas con bater as alcalinas 61 736 Indicaci n de bater a Se indica en la pantalla cuando el voltaje de la bater a descargada cae por debajo del nivel de operaci n Fuente de alimentaci n 2 Bater as AAA de 1 5 V NEDA R03 Incluye un compartimiento para bater a aislado Precisi n Precisi n especificada a 23 C 5 C humedad relativa lt 15 Coeficiente de 0 1 x precisi n
19. al voltaje Desconecte primero el cable de prueba rojo del voltaje e Trabaje siempre con un compa ero e Al usar las sondas mantenga los dedos lo m s detr s posible de las puntas de las mismas Caracter sticas e Medidor de pinza con selecci n de gama autom tica y manual e Indicaciones de valor eficaz rms real Modelo 61 736 nicamente e Detecci n de voltaje sin contacto 70 a 600 V CA e Medida de corriente hasta 400 A CA e Medida de voltaje de CA CC y resistencia e Verificaci n de continuidad con indicaci n audible e Retenci n de datos e Apagado autom tico e Indicador de bater a descargada e Mordazas compactas para penetrar en espacios estrechos e Protecci n electr nica contra sobrecarga en todas las gamas Page 3 ee Sujeci n con mordazas Palanca Selector de funciones Pantalla de cristal l quido LCD Terminal de entrada para voltaje y resistencia V Q Terminal de entrada com n COM Voltaje sin contacto Non Contact Voltage NCV Gama Retenci n de datos 0 Funciones de medida 10 i conos de la pantalla 11 Pantalla de 4000 cuenta 7 12 Unidades de medida 13 volts 14 amperes 15 ohms 16 Continuidad 17 Est seleccionada la medida de CA 6 18 Est seleccionada la medida de CC 19 Indicador de polaridad para CC 20 Indicador de bater a descargada 21 22 23 16 21 Gama l 22 Retenci n de datos Hom ES 17 8 23 Apagado autom tico
20. ding a fixed amount at 23 C 5 C 73 4 F 9 F less than 75 relative humidity Temperature Coefficient 0 1 times the applicable accuracy specification per degree C from 0 C to 18 C and 28 C to 50 C 32 F to 64 F and 82 F to 122 F Accuracy 61 732 61 736 1 7 6 digits 1 7 10 digits 3 0 6 digits 13 0 10 digits Overload Protection Range and Function Resolution 40 004 400 0A 40 00A 400 0A 50Hz 60Hz 60Hz 400Hz 400 0V 50Hz 500Hz 600V 50Hz 500Hz 1 2 5 digits 1 5 5 digits 1 2 8 digits 1 5 8 digits 600 VDC or AC rms 600 VDC or AC rms DC Voltage 400 0V 600V 0 5 2 digits 400 092 4 000kc2 40 00k02 400 0k Q 1 0 4 digits Resistance 600 VDC or AC rms 4 000MQ 40 00MQ 1 5 4 digits 3 0 5 digits Audible indication lt 250 600 VDC or AG rms Continuity Response time 500ms Accuracy stated for crest factor lt 3 Input Impedance is 10M Page 10 Warranty Statement 61 732 61 736 This tester is warranted to the original purchaser against defects in material and workmanship for the lifetime of the product During this warranty period IDEAL INDUSTRIES INC will at its option replace or repair the defective unit subject to verification of the defect or malfunction This warranty does not apply to Medidor de pinza defects resulting from abuse neglect accident unauthorized repair alteration or
21. e pas aux vices r sultant d une utilisation abusive de la n gligence d un accident d une r paration non autoris e ou d une utilisation d raisonnable PONS 35 Vantage Point Drive Toutes les garanties implicites r sultant de la vente d un produit IDEAL y com pris mais non de fa on limitative les garanties de valeur marchande et d adapta R h t NY 1 462 4 tion une fin particuli re sont limit es ce qui pr c de Le fabricant ne sera pas OC es er tenu responsable de la perte d utilisation de l instrument ou tout autre dommage indirect ou cons cutif d bours ou pr judice financier ou de toute r clamation ou 1 800 800 5001 r clamations pour tout dommage d bours ou pr judice financier s E 3 Les lois des tats variant il est possible que les limitations ou exclusions ci gt ici dessus ne s appliquent pas vous Cette garantie vous conf re des droits l gaux _ gt Visit us at Transcat com _ sp cifiques et il est possible que vous b n ficiez galement d autres droits lesquels varient d tat tat ND 4952 2 Made in Taiwan Hecho en Taiwan Fabriqu Taiwan Page 24
22. e will override the auto ranging feature of the meter A Co appears in the upper left side of the display Continue pressing the Range button until the desired range is obtained Use this mode to lock in a specific range for repeated measurements To return to the utoranging mode either depress the Range button for greater than 1 second or turn the meter off and then back on again et ata Hold Feature ess the Hold button on the side of the meter to toggle in and out of the data hold ode HOLD appears in the upper left of the meter display when data hold is ctive Use the data hold feature to lock a measurement reading on the display ess the Hold button again to unlock the display and obtain a real time reading T9 3 UT Auto Power Off APO Feature The meter automatically powers itself down after about 10 minutes of no use Press any button and the meter will wake up and display the last reading taken before power down This feature can be overridden by holding the Range button while turning the function switch from Off to any other position When APO is defeated the APO will be removed from the display Turning the meter off will restore the APO default Page 5 Measuring AC Current Amps CORRECT INCORRECT Single Currents Conductor cancel only Measuring Voltage AC Voltage
23. i n de selecci n autom tica de gama del medidor En el lado superior izquierdo de la pantalla aparece un Ce Contin e presionando el bot n Range Gama hasta llegar a la gama deseada Utilice este modo para mantener fija una gama espec fica cuando deba hacer medidas repetidas Para volver al modo de selecci n autom tica de gama puede mantener presionado el bot n Range Gama durante m s de 1 segundo o apagar el medidor y encenderlo nuevamente Caracter stica de retenci n de datos Presione el bot n Hold Retenci n ubicado en el costado del medidor para entrar y salir sucesivamente del modo de retenci n de datos Cuando la funci n de retenci n de datos est activa aparece en la parte superior izquierda de la pantalla del medidor la leyenda HOLD RETENCI N Utilice la caracter stica de retenci n de datos para fijar una lectura de medida en la pantalla Para que la indicaci n de la pantalla deje de estar fija y pueda obtenerse una lectura en tiempo real vuelva a presionar el bot n Hold Retenci n Page 5 Caracter stica de apagado autom tico Auto Power Off APO El medidor se desactiva autom ticamente despu s de 10 minutos sin uso Si en esa situaci n presiona cualquier bot n el medidor se reactivar e indicar en su pantalla la ltima lectura tomada antes de desactivarse Esta caracter stica puede ser anulada manteniendo presionado el bot n Range Gama mientras se hace girar el conmutador
24. ive equipment such as safety glasses face shields insulating gloves insulating boots and or insulating mats e Before each use Perform a continuity test by touching the test leads together to verify the functionality of the battery and test leads Use the 3 Point Safety Method 1 Verify meter operation by measuring a known voltage 2 Apply meter to circuit under test 3 Return to the known live voltage again to ensure proper operation e Never ground yourself when taking electrical measurements e Connect the black common lead to ground or neutral before applying the red test lead to potential voltage Disconnect the red test lead from the voltage first e Always work with a partne e When using the probes keep fingers as far behind the probe tips as possible m Features e Auto manual ranging clamp meter e Non Contact Voltage 70 600VAC e Measures 400 AAC Current e Measures AC DC Voltage and Resistance e Audible continuity e Data hold e Auto Power Off e Low Battery Indicator e Compact jaws for reaching into tight spaces e Electronic overload protection on all ranges 61 732 model is averaging sensing rms calibrated e 61 736 model is true rms sensing Page 3 Features Jaw Clamp Lever Function Dial Display LCD Volts and resistance V Q input terminal 6 Common COM input terminal 7 Non Contact Voltage NCV 8 Range 9 Data Hold 10 Measuring Functions or QUES
25. ta originada en la venta de un producto IDEAL incluyendo pero sin limitarse a ellas garant as impl citas de comerciabilidad y adecuaci n para un prop sito particular se limitan a lo indicado anteriormente El fabricante da os emerg no ser responsable por la p rdida del uso del instrumento u otros entes o concomitantes gastos o p rdida econ mica o por cualquier reclamaci n de dichos da os gastos o p rdidas econ micas Las leyes estatales var an por lo que las limitaciones o exclusiones anteriores pueden no aplicarse en su caso Esta garant a le da derechos legales espec ficos y usted puede tener tambi n otros derechos que var an de estado a estado Page 12 Multim tre pince Mode d emploi 61 732 61 736 Page 13 AVERTISSEMENT A Lire en premier Informations concernant la s curit Veiller comprendre et se conformer scrupuleusement au mode d emploi N utiliser le multim tre que de la fa on sp cifi e dans le pr sent manuel d faut la protection offerte par le multim tre pourra tre compromise A AVERTISSEMENT Pour viter tout risque d lectrocution de l sions personnelles ou de mort se conformer aux directives suivantes e Ne pas utiliser le multim tre s il para t endommag Examiner le multim tre pour s assurer que son bo tier n est pas fissur et que sa partie arri re est bien assujettie e Inspecter et remplacer les conducteurs si l
26. tion automatique manuelle de plage Le multim tre se met sur le mode de s lection automatique de plage quand on Pallume Sur ce mode le multim tre s lectionne la meilleure plage d affichage de la mesure Lorsqu on appuie sur le bouton de Plage du multim tre le mode de s lection manuelle de plage neutralisera la fonction de s lection automatique de plage du multim tre Un Co est affich dans le coin sup rieur gauche de l af fichage Continuer appuyer sur le bouton de plage Range jusqu ce qu on obtienne la plage d sir e Utiliser ce mode pour verrouiller une plage particuli re afin de proc der des mesures r p t es Pour retourner sur le mode de s lection automatique de plage appuyer sur le bouton Range plage pendant plus d une seconde ou teindre le multim tre et le rallumer Fonction de r tention des donn es Appuyer sur le bouton Hold r tention situ sur le c t du multim tre pour bas culer dans et hors du mode de r tention des donn es HOLD est affich dans le coin sup rieur gauche de l affichage du multim tre quand la fonction de r ten tion des donn es est active Utiliser la fonction de r tention des donn es pour verrouiller une lecture de mesure sur l affichage Appuyer nouveau sur le bou ton Hold R tention pour d verrouiller l affichage pour obtenir une lecture en temps r el Page 17 Fonction Arr t automatique de l alimentation APO Ce multim tre s teint