Home
low profile veterinary scale model 2842kl
Contents
1. Touche Pi ce N Description Quantit N 1 3811201 0 TAPIS EN CAOUTCHOUC 1 2 3811101 0 PLATEFORME 1 3 3610601 0 PLAN DE COUVERTURE 1 4 ECROU D AUTO VERROUILLAGE M5 32 5 3811001 0 ENSEMBLE CHASSIS 1 6 VIS PAN PHIL NC6 1 4 2 7 2138302 0 BOITIER DE JONCTION 5 8 400142 DECHARGE DE TRACTION 1 9 1304201 0 CELLULE DE CHARGE 4 10 3810001 0 PIED EN CAOUTCHOUC 3 8 4 11 RONDELLE EN CAOUTCHOUC 4 12 VIS HEX NC5 16 3 4 8 13 2005502 0 BOITIER JON CABLE DU TABLEAU DE 1 CONTROLE 14 2138803 0 TABLEAU FALCON 1 15 VIS PHIL NC6 1 4 6 16 3812901 0 BOITIER EL 1 17 ECROU DE NC 6 2 18 2033301 0 TABLEAU DE CONTROLE CABLE DE 1 DEUX BROCHES 19 401124 BARRETTE SOUTIEN POUR LES PILES 1 20 3612601 0 COUVERCLE ARRIERE 1 21 2032801 0 SUPPORT DE PILES 1 22 VIS A PLASTIQUE M6 12 2 23 PILES C 6 24 2032701 0 TABLEAU DE CONTROLE POUR CHARGER LE 1 CABLE DE LA CELLULE 25 400525 SUPPORT DE CABLE P G 7 1 26 3613001 0 SUPPORT D AFFICHAGE 1 27 PIED PLASTIQUE ROND 4 28 3513201 0 CADRAN PELSTAR 2842 1 29 RONDELLE EN PLASTIQUE M6 2 30 VIS A TETE ROSETTE M6 13 5 2 31 2033001 0 ADAPTATEUR CABLE DU TABLEAU DE 1 CONTROLE 32 420964 ADAPTATEUR 120VCA 9VDC 1 21 GARANTIE GARANTIE LIMIT E Que couvre la garantie compter de la date d achat les p se personnes Pelstar LLC sont gara
2. dd au A 9 PARTS LIST un n a GE dak el y 10 e ip 11 CAUTION AND WARNING e prevent injury never leave animal unattended while on the scale 9 To prevent injury do not transport the scale while the animal is in the weighing tray For accurate animal weighing the scale must be placed on a flat stable surface For accurate weighing verify proper operation according to the procedure described in this manual before each use e Do not use in the presence of flammable materials e Operating at other voltages and frequencies than specified could damage the equipment e Ifthe LO BAT indicator activates for accurate weighing replace the batteries or connect the scale to an AC power source as soon as possible SPECIFICATIONS GENERAL Health o meter s Low Profile Veterinary Scale model 2842KL uses highly sophisticated microprocessor technology Each precision instrument is designed to provide accurate reliable and repeatable weight measurements and features that make the weighing process simple fast and convenient The actual weighing is performed by motion sensing weighing technology to determine the weight of an active animal The animal s weight can be displayed in pounds or in kilograms The scale includes a specially designed removable rubber mat for easy cleaning The unit can be operated using its AC power adapter or by 6 C cell batterie
3. Conecta y desconecta la balanza Boton REWEIGH Permite repetidos pesajes del animal ZERO Display Digital de Ceros antes del pesaje Permite la cancelaci n tara del peso de la estera otros accesorios en la balanza Bot n LBS KG Selecciona kilogramos libras 5 Indicador BAT Cuando ON indica que las baterias de la balanza estan bajas Las baterias deben ser sustituidas 6 Indicador ZERO Cuando ON indica que la balanza esta estable y lista para ser usada 7 Display Digital LCD de 6 Exhibe el peso del animal en kilogramos 0 libras como Digitos se ve por el indicador LB en el lado derecho del display Cuando el bot n REWEIGH es liberado el display hasta que el peso del animal sea determinado Indicador LB Cuando ON indica la exhibici n del peso en libras Indicador KG Cuando ON indica la exhibici n del peso en kilogramos 27 INSTRUCCIONES DE OPERACION Presione el bot6n ON OFF para activar la balanza 2 Espere hasta que aparezca 0 0 en el display digital 3 Si usted elige usar una estera manta u otro accesorio sobre la goma incorporada aseg rese que las bordas del accesorio est n en la bandeja y no tocando la superficie donde la balanza est posicionada Presione el bot n ZERO para cancelar el peso del accesorio que est en la balanza 4 Coloque el animal la balan
4. Figura 1 Montaje Despu s del Env o Coloque la unidad de la base al rev s en una superficie estable Atornille los cuatro pies a la unidad de la base seg n lo demostrado D vuelta a la unidad de la base con el lado correcto para arriba Enchufe el cable conector del display al cable conector de la base SAR NR ES Coloque la unidad de la base sobre la mesa o m ntela en la pared como deseado Para montar la unidad la base en la pared use broca de 5 16 o 8mm 6 Coloque la estera de goma sobre la unidad la base dentro del marco designado La balanza puede ser operada por un adaptador de fuente de energ a CA o por 6 bater as C La balanza pasar autom ticamente a ser operada por bater a cuando la fuente de energ a CA estuviera ausente 25 CONFIGURACION Coloque las baterias en el soporte de la bateria ver Cambiando las Baterias abajo 2 Conecte el adaptador de la balanza a la unidad de display y al origen de energia 3 Presione el bot n ON OFF para activar la balanza El display empezara a mostrar start y despu s 0 0 4 Cuando la funci n de auto prueba est completa El display digital debe mostrar 0 0 LB debe estar indicado en lado derecho del display Para cambiar las unidades predeterminadas de la balanza a kilogramos Kg por favor contacte nuestro Centro de Soporte T cnico el 1 800 638 3722 1 708 598 9100 5 Ponga un peso no superior a 600
5. The scale will automatically switch to battery operation when an AC power source is absent SET Place batteries in battery holder see Replacing Batteries below Plug the scale s AC adapter into the display assembly and into the power source Press the ON OFF button to turn the scale on The display will show start and then 0 0 4 When the self test function is complete The digital display should read 0 0 LB should be indicated on the right side of the display To change the default units of the scale to kilograms Kg please contact our Technical Support Center at 1 800 638 3722 or 1 708 598 9100 5 Place a weight not to exceed 600 Lb 270 Kg on the scale The digital display will blink until the weight calculation is complete Press the LBS KG button to select the weight mode either in kilograms or pounds Press the REWEIGH button the digital display should read again the weight of the item on the scale 8 Remove the weight from the scale The digital display should continue to read the weight of the item that was on the scale 9 Press the ZERO button the digital display should return to zero 10 Disconnect the power source connector from the scale then turn the scale on using ON OFF button The scale should automatically switch to battery power NOTE If the set up procedure failed go to the troubleshooting instructions If the problem is not corrected ref
6. UL La balanza esta en condici n de carga negativa Asegurese que la estera de goma est colocada sobre la base El display muestra LO BAT Las baterias estas bajas Cambie las baterias las instrucciones 29 TRAYECTORIA DE CALIBRACION Los modos son accesibles manteni ndose presionadas ciertas teclas despu s de la activaci n Las teclas deben ser presionadas y mantenidas asi por lo menos tres segundos Explicaci n del Organigrama Action gt gt Display Alterno Presione y mantenga asi por lo menos por 3 segundos REWEIGH REWEIGH REWEIGH Tecla Reweigh ZERO Tecla Zero Tecla ON OFF Prenda la balanza display StArt 200 0 LB IMPORTANTE La balanza debe estar libre al ser calibrada Calibraci n cero PUT 200 0 LB Coloque el peso de calibraci n en la balanza Retire el peso de la balanza VISTA DETALLADA DE BALANZA 49 03 42 49 09 31 LISTA DE PIEZAS No Parte No Descripcion Cde 1 3811201 0 ESTERA DE GOMA 1 2 3811101 0 PLATAFORMA 1 3 3810601 0 TAPA 1 4 AUTO CONTRATUERCA M5 32 5 3811001 0 UNIDAD DE LA BASE DE LA BALANZA 1 6 TORNILLO PAN HEAD PHIL NC6 1 4 2 7 2138302 0 ENSAMBLADURA 5 6 400142 ALIVIO DE TENSION 1
7. 9 1304201 0 CELULA DE 4 10 3810001 0 PIE DE BC3 8 4 11 ARANDELA DE CAUCHO 4 12 MANGUITO ROSCADO HEX NC5 16 3 4 8 13 2005502 0 CAJA DE CABLE DEL TABLERO 1 PRINCIPAL 14 2138803 0 TABLERO FALCON 1 15 TORNILLO PAN HEAD PHIL NC6 1 4 6 16 3812901 0 EL CAJA 1 17 TUERCA CON ARANDELA DE FRENO NC6 2 18 2033301 0 TABLERO PRINCIPAL CON CABLE DE DOS 1 PERNOS 19 401124 CORREA DEL SOPORTE DE LA BATERIA 1 20 3812601 0 TAPA POSTERIOR 1 21 2032801 0 SOPORTE DE LA BATERIA 1 22 TORNILLO DE CABEZA PLASTICA M6 12 2 23 BATERIAS C 6 24 2032701 0 CABLE DEL TABLERO PRINCIPAL PARA 1 CELULA DE CARGA 25 400525 SOPORTE DEL CABLE P G 7 1 26 3813001 0 SOSTENEDOR DEL DISPLAY 1 27 PIERNA REDONDA DE PLASTICO 4 28 3513201 0 PLATO PELSTAR 2842 1 29 ARANDELA DE PLASTICO M6 2 30 TORNILLO DE CABEZA ROSETTE M6 13 5 2 31 2033001 0 ADAPTADOR CABLE DEL 1 PRINCIPAL 32 420964 ADAPTADOR 120VAC 9VDC 1 32 GARANTIA GARANTIA LIMITADA Qu Cubre la Garantia Las balanzas de Pelstar LLC estan garantizadas a partir de la fecha de compra contra defectos de fabricaci n y mano de obra por un periodo de un 1 a o Si el funcionamiento del producto no fuese adecuado regrese el producto a Pelstar con fletes prepagados y en un embalaje adecuado Vea Para obtener Servicio de Garantia debajo para de instrucciones Si el fabricante determinase la existencia de un defecto de fabricaci n mano de obra el remed
8. ferme et renouvelez le processus de la pes e 4 V rifiez le poids avec un poids de valeur connue L cran affiche OL Le poids pos sur la balance d passe la capacit de l appareil Retirez l exc dent de poids et utilisez la balance en tenant compte de ses limites L cran affiche UL Le poids pos sur la balance est inf rieur sa capacit V rifiez que le tapis en caoutchouc est bien plac sur le ch ssis L cran affiche LO BAT Les piles sont faibles Remplacez les piles suivant les instructions 18 DE L acc s aux modes de calibrage fait en maintenant certaines touches appuy es apr s la mise sous tension et ce pendant au moins trois secondes ORDINOGRAMME Action REWESH Touche de repes e Zz Affichage ZERO Touche z ro onorr Interrupteur de Marche Arr t gt gt Affichage altern Allumez l appareil affichage Start Appuyez et maintenez ainsi 3 secondes au moins Zero 200 0 LB IMPORTANT La balance doit tre vid e de ses donn es pour le calibrage REWEIGH Calibrage z ro 200 0 LB Placez le poids de calibrage sur l appareil Retirez le poids du plateau 19 SCHEMA DE BALANCE VETERINAIRE EN PIECES DETACHEES 69 69 98 40 49 9 20 LISTE DES PIECES
9. Health o meter LOW PROFILE VETERINARY SCALE MODEL 2842KL BALANCE VETERINAIRE MODELE 2842KL BALANZA VETERINARIA MODELO 2842KL OPERATION MANUAL MODE D EMPLOI MANUAL DE OPERACI N LOW PROFILE VETERINARY SCALE MODEL 2842KL Thank YOU for your purchase of this product Please read this manual carefully and keep it handy for ready reference Merci d avoir achet ce produit Veuillez lire attentivement ce manuel et le garder port e de main pour pouvoir le consulter tout moment Gracias por la adquisici n de este producto Lea por favor este manual cuidadosamente y mant ngalo a su alcance para una pronta referencia 1 ERANGAIS 12 ESPA OL 23 TABLE OF CONTENTS CAUTION AND WARNING EE EE 2 9 PECIFICA MON E 2 ASSEMBLY INSTRUCTIONS ada ai a i da lia 3 SETUP E tot dd 4 OPERATION INSTRUCTIONS 6 MAINTENANCE SS 6 TROUBLEESFIOOTING as 7 CALIBRATION PA TH han imakak iaa 8 EXPLODED VIEW OF SCALE
10. LCON BOARD 1 15 PHIL PAN HEAD SCREW 6 1 4 6 16 3812901 0 EL BOX 1 17 NUT WITH LOCK WASHER NC6 2 18 2033301 0 MAIN BOARD CONN TWO PIN CABLE 1 19 401124 BATTERY HOLDER STRAP 1 20 3812601 0 REAR COVER 1 21 2032801 0 BATTERY HOLDER 1 22 PLASTIC HEAD SCREW M6 12 2 23 C CELL BATTERIES 6 24 2032701 0 MAIN BOARD TO LOAD CELL CABLE 1 25 400525 CABLE HOLDER P G 7 1 26 3813001 0 DISPLAY HOLDER 1 27 ROUND PLASTIC LEG 4 28 3513201 0 FACE PLATE PELSTAR 2842 1 29 PLASTIC WASHER M6 2 30 ROSETTE HEAD SCREW M6 13 5 2 31 2033001 0 ADAPTER MAIN BOARD CABLE 1 32 420964 ADAPTER 120VAC 9VDC 1 10 LIMITED WARRANTY What does the Warranty Cover Pelstar LLC scales are warranted from date of purchase against defects of materials or in workmanship for a period of one 1 year If product fails to function properly return the product freight prepaid and properly packed to Pelstar See To Get Warranty Service below for instructions If manufacturer determines that a defect of material or in workmanship exists customers sole remedy will be repair or replacement of scale at no charge Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value All parts including repaired and replaced parts are covered only for the original warranty period Who is Covered The original purchaser o
11. Lb 270 en la balanza display digital debera parpadear hasta que el c lculo del peso sea completado 6 Presione el bot n LBS KG para seleccionar el modo de peso o en kilogramos o en libras 7 Presione el bot n REWEIGH el display digital deber mostrar nuevamente el peso del tem en la balanza 8 Retire el peso de la balanza El display digital deber continuar mostrando el peso del tem que estaba en la balanza i Presione el bot n ZERO el display digital debe volver a cero 10 Desconecte la fuente de energ a CA de la balanza y active la balanza usando el bot n ON OFF La balanza debe automaticamente pasar su energ a por bater a NOTA Si el procedimiento de configuraci n falla dir jase a las instrucciones de soluci n de problemas Si el problema no es corregido refi rase al personal de servicio calificado Cambiando las Bater as EXD TORNILLOS DE PLASTICO lt SOPORTE DE LA BATERIA Figura 2 Cambiando las Bater as Desconecte la balanza de la fuente de energ a CA Desatornille los dos tornillos plasticos y quite cuidadosamente el soporte de la bater a de la unidad de display Libere la correa de sujeci n de las bater as Substituya las bater as por nuevas y reate la correa Coloque el soporte de la bater a en la unidad de display y reinstale los dos tornillos pl sticos 26 CONFIGURACION Figura 3 Panel de Control DESCRIPCION FUNCION Boton ON OFF
12. TAJE e aaa aaa aaa aa 25 CONEIGURACI N Q u AN M De fate erati clau a 26 INSTRUCCIONES DE OPERACI N nn cala a e 28 MANTENIMIENTO dicas aa 28 SOLUCI N DE PROBLEMAS I aaa ae 29 TRAYECTORIA DE CALIBRACI N 30 VISTA DETALLADA DE LA BALANZA 31 LISTADEBIEZAS A ta ut Oa a ana 32 SARANEIA cae ed u Tu ata EE 33 23 PRECAUCION ADVERTENCIA e Para evitar lesiones nunca deje al animal solo mientras est en la balanza e evitar lesiones no traslade la balanza mientras el animal esta en la bandeja de pesaje e Para un pesaje exacto del animal la balanza debe ser colocada en una superficie plana estable Para un pesaje exacto verifique antes de cada uso la apropiada operaci n segun los procedimientos descritos en este manual e No use en presencia de materiales inflamables e Operando en otros voltajes y frecuencias que los especificados puede hacer da o al equipo e Sielindicador de LO BAT se activa para un pesaje exacto cambie las bater as o conecte la balanza a una fuente de energ a CA lo m s pronto posible ESPECIFICACIONES GENERAL La Balanza Veterinaria de Health o meter modelo 2842KL usa la tecnolog a de microprocesador altamente sofisticada Cada instrumento de precisi n es
13. UCTIONS Press the ON OFF button to turn the scale on 2 Wait until appears on the digital display 3 If you choose to use a mat blanket or other accessory on top of the built in rubber make sure that the edges of the accessory are on the scale and are not touching the surface on which the scale is positioned Press the ZERO button to cancel the weight of the accessory that is on the scale 4 Place an animal on the scale The display will blink until the weight of the animal is determined 5 If you wish to reweigh without to remove and to place an animal on the scale again press the REWEIGH button 6 Remove the animal from the scale The digital display should continue to read the animal s weight until REWEIGH or ZERO button is pressed NOTE After 2 minutes of inactivity the scale will turn itself off to conserve power To restart the scale press the ON OFF button MAINTENANCE GENERAL This section provides instructions for maintenance cleaning troubleshooting and operator replaceable parts for the Low Profile Veterinary Scale model 2842KL Maintenance operations other than those described in this section should be performed by qualified service personnel MAINTENANCE Before first use and after periods of non use check the scale for proper operation and function If the scale does not operate correctly refer to qualified service personnel 1 Check overall appearance of the total
14. connectez la balance v t rinaire de la source lectrique CA 1 Nettoyez toutes les surfaces externes l aide d un chiffon ou d une lingette humide et propre Vous pouvez utiliser de l eau et du savon doux S chez ensuite avec un chiffon doux et propre Ne trempez pas le ch ssis de la balance ni le bloc d affichage dans une solution de nettoyage ou n importe quel autre liquide 3 N utilisez pas d alcool isopropylique ou autres solutions pour nettoyer l cran d affichage N LOCALISATION DES PANNES Reportez vous aux instructions suivantes pour d finir et ventuellement corriger une panne avant d appeler un technicien qualifi SYMPTOME CAUSE POSSIBLE ACTION CORRECTIVE La balance v t rinaire ne s allume pas 1 Les piles sont mortes 2 La prise lectrique est d fectueuse 3 Mauvaise alimentation lectrique 1 Remplacez les piles 2 Utilisez une autre prise 3 Changez l adaptateur Le poids affich est contestable ou la balance ne se remet pas z ro 1 corps tranger provoque une interf rence avec la balance 2 L cran n a pas affich la mention 0 0 avant la pes e 3 La balance v t rinaire n est pas pos e sur une surface ferme 4 La balance n est pas bien calibr e 1 Retirez l objet interf rant de la balance 2 Retirez l animal de la balance remettez la z ro et recommencez la pes e 3 Placez l appareil sur une surface
15. e lectrique ensuite allumez la l aide de l interrupteur Marche Arr t ON OFF L appareil doit se r gler automatiquement sur piles REMARQUE Si la proc dure d installation a chou consultez les instructions relatives la localisation des pannes Si le probl me persiste veuillez avoir recours au technicien comp tent Remplacement des piles VIS EN PLASTIQUE SUPPORT DE PILES Figure 2 Remplacement des piles 1 D branchez la balance v t rinaire de la source d alimentation CA 2 Desserrez deux vis en plastique et retirez avec pr cautions le support de piles du bloc d affichage 3 D gagez la barrette de soutien des piles Remplacez les piles usag es par des piles neuves et remettez la barrette en place 4 Positionnez le support de piles dans le bloc d affichage et fixez le nouveau avec deux vis en plastique 15 INSTALLATION Figure 3 Tableau de contr le INDICATEUR DESCRIPTION FONCTION 1 Interrupteur de Marche Allume ON et teint OFF la balance Arr t ON OFF 2 Touche de repes e Permet de renouveler la pes e de l animal REWEIGH 3 Touche ZERO Remet l cran num rique z ro avant la pes e Permet d annuler le poids tare du tapis ou de tout autre objet qui aurait ventuellement t pos sur le plateau 4 Touche LBS KG S lectionne l unit de poids kilogrammes ou livres 5 Indicateur BAT En position ON il indique que le
16. e repes e REWEIGH 6 Retirez l animal de la balance L cran num rique doit continuer afficher le poids de l animal pes tant que l une des touches REWEIGH ou ZERO n a pas t appuy e REMARQUE Apr s 2 minutes d inutilisation la balance v t rinaire s teindra automatiquement conomisant ainsi l lectricit et les piles Pour la remettre en marche il vous suffit d appuyer sur la touche de Marche Arr t ON OFF MAINTENANCE GENERALITES Cette partie donne les instructions de maintenance nettoyage localisation des pannes et pi ces remplagables par l op rateur pour la balance v t rinaire mod le 2842KL Toute op ration de maintenance autre que l une de celles d crites dans cette partie devra tre accomplie par un technicien qualifi D MAINTENANCE Avant la premi re utilisation et apr s toutes p riodes de non utilisation v rifiez le bon tat de marche et le fonctionnement pr cis de la balance Si celle ci ne fonctionne pas correctement veuillez consulter le technicien comp tent 1 V rifiez l aspect g n ral de la balance pour y d celer tout ventuel dommage ou usure 2 Contr lez l adaptateur CA en observant la pr sence ventuelle de craquelures ou usure du c ble ou encore de broches cass es ou tordues NETTOYAGE Un entretien et un nettoyage appropri s sont essentiels l assurance de l efficacit et de la haute pr cision long terme de l appareil D
17. er to qualified service personnel Replacing Batteries R gt W BERN 20 PLASTIC SCREWS BATTERY HOLDER Figure 2 Replacing Batteries Disconnect the scale from the AC power source Unscrew two plastic screws and carefully remove the battery holder from the display assembly Release attachable strap from the batteries Replace the batteries with new ones and reattach the strap Position the battery holder into the display assembly and reinstall two plastic screws Figure 3 Control Panel ITEM DESCRIPTION FUNCTION 1 ON OFF button Turns scale ON and OFF REWEIGH button Allows repeated reweighing of animal ZERO button Zeros Digital Display prior to weighing Enables the cancellation tare of weight of mat or other accessories on the scale LBS KG button Selects kilograms or pounds 5 BAT indicator When ON indicates scale batteries are low The batteries should be replaced 6 ZERO indicator When ON indicates the scale is stable and ready for use 7 Digital Display 6 Digit Displays animal weight in kilograms or pounds as shown by the LB or indicator on the right side of the display When REWEIGH button is depressed display will blink until animal e weight is determined LB indicator When ON indicates displaying weight in pounds KG indicator When ON indicates displaying weight in kilograms OPERATION INSTR
18. f the product must have proof of purchase to receive warranty service Pelstar dealers or retail stores selling Pelstar products do not have the right to alter or modify or any way change the terms and conditions of this warranty What is Excluded Your warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instruction abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get Warranty Service Make sure you keep your sales receipt or document showing proof of purchase Call 1 800 815 6615 or 1 708 598 9100 to receive a return authorization number Attach proof of purchase to your defective product along with your name address daytime telephone number and description of the problem Carefully package the product and send with shipping and insurance prepaid to Pelstar LLC Attention R A Repair Department 7400 W 100th Place Bridgeview IL 60455 If your scale is not covered by warranty or has been damaged an estimate of repair costs or replacement costs will be provided to you for a
19. io unico sera la reparaci n reemplazo de la balanza sin cargo alguno para el cliente El se realizara con un equipo componente nuevo remanufacturado Si el producto se encontrase fuera producci n se le remplazara con un producto similar del mismo o mayor valor Todas las partes incluyendo las partes separadas remplazadas estan cubiertas Unicamente durante el periodo original de la garantia Qui n Esta Cubierto El comprador original del producto debe poder comprobar la compra para hacer v lida la garant a Los distribuidores o minoristas de Pelstar no tienen derechos para alterar modificar o cambiar de ninguna manera los t rminos y condiciones de esta garant a Qui n Est Excluido La garant a no cubre el desgaste normal de las partes o da os como resultado de Uso negligente o mal uso del equipo uso de voltajes o corrientes inapropiadas utilizaci n contraria a las instrucciones de operaci n abuso incluyendo modificaciones da os en transporte reparaciones o alteraciones no autorizadas M s a n la garant a no cubre sucesos naturales como fuego inundaciones huracanes o tornados Esta garant a le d a Ud derechos legales espec ficos puede tener adem s otros derechos que var an de pa s a pa s estado a estado provincia a provincia o jurisdicci n a jurisdicci n Para obtener Servicio de Garant a Aseg rese de conservar su recibo de venta o un documento que demuestre prueba de la com
20. iques Adaptateur 120VCA 60Hz 6 piles Environnement Temp ratures de fonctionnement 50 F a 95 F 10 C 35 C Temp ratures de stockage 30 F 125 F 0 C 50 C Humidit 85 Dimensions Longueur 42 106 6 cm Largeur 2238 56 6 Hauteur 2 5 cm Poids 45 Lb 20 45 Kg MODE D ASSEMBLAGE La balance v t rinaire 2842KL a t calibr e en usine Elle est fournie en quatre parties assembler le ch ssis le bloc d affichage le tapis et les pieds en caoutchouc Retirez chaque partie de son carton et d ballez la avec pr caution pour viter d en rayer les divers c t s BLOC D AFFICHAGE ADAPTATEUR CA CONNECTEUR DU CABLE DU CHASSIS CHASSIS TAPIS EN CAOUTCHOUC Figure 1 Assemblage apr s envoi Mettez le ch ssis l envers sur une surface ferme Fixez les quatre pieds au ch ssis en les vissant comme l indique l illustration Remettez le ch ssis l endroit Branchez le connecteur du c ble de l affichage celui du c ble du ch ssis Oe P NS Placez le ch ssis sur la table ou fixez le au mur selon votre choix Pour effectuer une installation murale du ch ssis utilisez une m che de 5 16 ou 8 mm 6 Placez le tapis en caoutchouc sur le ch ssis dans le cadre qui lui est destin La balance v t rinaire fonctionne avec un adaptateur lectrique CA ou avec 6 piles C En l absence d une source lectrique CA la balance se r glera au
21. ntis contre les d fauts de mat riel ou de fabrication pour une p riode d un 1 an Renvoyez Pelstar port pay et bien emball le produit qui fonctionne mal Voir Pour Obtenir un Service de Garantie ci dessous pour des instructions Si le fabricant constate un d faut de mat riel ou de fabrication le p se personne sera r par ou chang sans aucun frais pour le client Le remplacement se fera avec un produit ou composant neuf ou corrig Si le produit n est plus disponible le remplacement se fera par un appareil similaire d une valeur gale ou sup rieure Les frais de toutes les pi ces r par es ou chang es sont couvertes seulement pour la p riode de garantie originale Qui est couvert par la garantie Le premier acheteur du produit doit avoir les pi ces justificatives de lui donnant droit au service de garantie Les concessionnaires ou les d taillants des produits Pelstar n ont pas le droit de modifier ou de changer les termes et conditions de cette garantie Ce que la garantie ne couvre Votre garantie ne couvre pas une usure normale des pi ces ou un dommage r sultant des l ments suivants n gligence ou mauvais usage du produit branchement sur un courant ou un voltage non appropri usage non conforme au mode d emploi abus comprenant le fait de trifouiller l appareil le dommage occasionn pendant le transport les r parations alternance sans autorisation De plus la garantie ne couvre pa
22. pproval prior to servicing or replacing Pelstar LLC 7400 West 100th Place Bridgeview IL 60455 1 800 815 6615 or 1 708 598 9100 www healthometermedical com Health o meter is a registered trademark of Sunbeam Products Inc Boca Raton FL 33431 11 BALANCE VETERINAIRE MODELE 284281 TABLE DES MATIERES PREGAUTION ET PREVENTION e ai a a 13 SPECIFICATIONS td 13 MODE D ASSEMBLAGE tat 14 INSTALLATION EE 15 MODE DE FONCTIONNEMENTT 17 MAINTENANCE ec a E Te Esa 17 LOCALISATION DES PANNES 18 MODE DECAEIBRACE ren A 19 SCHEMA DU PESE PERSONNE EN PIECES 20 LISTE DES PIECES nets chya A A en relate 21 GARANTE Sen za A a u ua ela ada da As 22 12 PRECAUTION ET PREVENTION Pour pr venir toute blessure accidentelle ne laissez jamais un animal sans surveillance sur la balance Pour pr venir toute blessure accidentelle ne transportez jamais la balance avec l animal sur le plateau Pour obtenir une lecture du poids exacte placez la balance v t rinaire sur une surface plane et stable Pour obtenir une lec
23. pra Llame 1 800 815 6615 o 1 708 598 9100 para recibir un n mero de autorizaci n para retorno Adjunte prueba de la compra al producto con defecto junto con su nombre direcci n n mero de tel fono de d a y descripci n del problema Empaquete el producto cuidadosamente y env elo con transporte y seguro pagados por adelantado a Pelstar LLC Atenci n R A Departamento de Reparaci n 7400 W 100th Place Bridgeview IL 60455 Si su balanza no est cubierta por garant a o ha sido da ificada un presupuesto de los costos de reparaci n o reemplazo ser prove do a usted para aprobaci n antes del mantenimiento o reemplazo Pelstar LLC 7400 West 100th Place Bridgeview IL 60455 1 800 815 6615 or 1 708 598 9100 www healthometermedical com Health o meter es una marca registrada de Sunbeam Products Inc Boca Raton FL 33431 33
24. proyectado para proveer medidas de peso exactas confiables repetibles y caracter sticas que hacen el proceso de pesaje simple r pido y conveniente El pesaje propiamente dicho es realizado por medio de tecnolog a de pesaje que detecta movimiento para determinar el peso de un animal activo El peso del animal puede ser presentado en libras o en kilogramos La balanza incluye una estera de goma especialmente proyectado para limpieza m s f cil La unidad puede ser operada usando su adaptador de energ a CA o por medio 6 bater as C ESPECIFICACIONES DE LA BALANZA Capacidad y Resoluci n 600 Lb x 0 2 Lb 270 Kg x 0 1 Kg Requerimientos de Energia Adaptador 120VCA 60Hz 6 x bater as de tama o Ambiental Temperaturas de Operaci n 50 F hasta 95 F 10 C hasta 35 de Almacenamiento 30 F hasta 125 0 C hasta 50 C Humedad 85 Dimensiones Fisicas Largo 42 106 6 cm Ancho 22 56 8 cm Altura 2 5 cm Peso 45 Lb 20 45 Kg 24 INSTRUCCIONES DE MONTAJE Esta balanza 2842KL ha sido calibrada en f brica Es enviada en cuatro partes montadas la unidad de la base la unidad de display la estera de goma y los pies de goma Saque cada unidad de su cart n y desempaquete el material cuidadosamente para evitar ralladuras en las partes de la unidad UNIDAD DE DISPLAY ADAPTADOR CA CABLE CONECTOR DE LA BASE UNIDAD DE LA BASE ESTERA DE GOMA
25. s SCALE SPECIFICATIONS Capacity and Resolution 600 Lb x 0 2 Lb 270 Kg x 0 1 Kg Power Requirements Adapter 120VAC 60Hz 6 x C size batteries Environmental Operating temperatures 50 F to 95 F 10 C to 35 C Storage temperatures 30 F to 125 F 0 C to 50 C Humidity 85 Physical Dimensions Length 42 106 6 cm Width 22 56 8 cm Height 2 5 cm Weight 45 Lb 20 45 Kg ASSEMBLY INSTRUCTIONS This 2842KL scale has been calibrated at the factory It is shipped in four assembled parts the base assembly the display assembly the rubber mat and rubber feet Remove each assembly from its carton and unwrap packing material carefully to prevent scratching the units parts DISPLAY ASSEMBLY AC ADAPTER BASE CABLE CONNECTOR BASE ASSEMBLY a RUBBER MAT Figure 1 Assembly After Shipment Place the base assembly upside down on a steady surface Screw the four feet onto base assembly as shown Turn the base assembly right side up Plug the display cable connector into the base cable connector SEP e Place the display assembly the table or mount it on wall as desired For mounting the display assembly on the wall use 5 16 or 8mm drill bit 6 Place the rubber mat on the base assembly inside the designated frame The scale may be operated by an AC power source adapter or by 6 C cell batteries
26. s les catastrophes naturelles comme l incendie l inondation l ouragan et la tornade Cette garantie vous donne des droits l gitimes sp cifiques Le client peut galement b n ficier de certains autres droits qui varient selon les pays les tats les provinces ou les juridictions Pour obtenir un service de garantie Assurez vous d avoir conserv votre re u ou tout autre document prouvant votre achat Appelez le 1 800 815 6615 ou le 1 708 598 9100 pour recevoir un num ro d autorisation de renvoi Joignez votre preuve d achat au produit d fectueux en indiquant vos nom adresse num ro de t l phone dans la journ e et en donnant une description du probl me Emballez soigneusement le produit envoyez le avec port et assurance pay s d avance Pelstar LLC Attention R A Repair Department 7400 W 100th Place Bridgeview IL 60455 Si votre p se b b n est pas couvert par la garantie ou a t endommag une estimation des frais de r paration ou de remplacement sera soumise votre approbation avant l ex cution de la r paration ou du remplacement Pelstar LLC 7400 West 100th Place Bridgeview IL 60455 1 800 815 6615 or 1 708 598 9100 www healthometermedical com Health o meter est une marque d pos e de of Sunbeam Products Inc Boca Raton FL 33431 22 BALANZA VETERINARIA MODELO 284281 INDICE PRECAUCI N Y ADVERTENCIA EEN 24 ESPEGIFIGAGIONE Si xx ae Ta UE KL 24 INSTRUCCIONES DE MON
27. s piles sont faibles et doivent tre remplac es 6 Indicateur ZERO En position ON il indique que la balance est stable et pr te l emploi 7 Ecran num rique LCD Affiche le poids de l animal en kilogrammes ou 6 chiffres livres selon la s lection de l indicateur LB ou KG sur le c t droit de l cran Quand la touche de repes e REWEIGH est appuy e l affichage lt y clignote jusqu d termination du poids de l animal 8 Indicateur LB En position ON il indique l affichage du poids en livres 9 Indicateur KG En position ON il indique l affichage du poids en kilogrammes 16 MODE DE FONCTIONNEMENT Appuyez sur l interrupteur de Marche Arr t ON OFF pour allumer l appareil Attendez que la mention 0 0 apparaisse sur l cran num rique Si vous avez d cid de placer un tapis une petite couverture ou un autre accessoire sur le caoutchouc int gr du plateau v rifiez que les bords de cet accessoire sont bien sur le plateau et ne touchent pas la surface sur laquelle la balance est pos e Appuyez sur la touche ZERO pour annuler le poids de la couverture ou de tout autre accessoire pos sur le plateau Placez l animal sur la bascule L affichage clignotera jusqu d termination du poids de l animal 5 Si vous souhaitez effectuer une nouvelle pes e sans retirer et remettre l animal sur la balance il vous suffit d appuyer sur la touche d
28. s superficies externas con un pa o h medo limpio o con tis Una soluci n suave de jab n y agua puede ser usada Seque con un pa o suave limpio 2 No sumerja la base de la balanza o la unidad de display en soluciones de limpieza u otro l quido 3 No use Alcohol Isopropilo u otras soluciones para limpiar la superficie del display SOLUCION DE PROBLEMAS Refi rase a las siguientes instrucciones para verificar y corregir cualquier falla antes de contactar al personal de servicio SINTOMA POSIBLE CAUSA ACCI N CORRECTIVA La balanza no se prende 1 Bateria terminada 2 Enchufe el ctrico con defecto 3 Mala fuente de energia 1 Cambie las baterias 2 Use otro enchufe 3 Sustituya el adaptador Peso cuestionable o la balanza no vuelve a cero Objeto externo interfiriendo en la balanza 2 El display no mostr 0 0 antes del pesaje 3 La balanza no esta colocada sobre una superficie estable 4 La balanza no esta calibrada Remueva de la balanza el objeto que esta interfiriendo 2 Remueva el animal vuelva la balanza a cero y empiece el proceso de pesaje nuevamente 3 Coloque la balanza en una superficie estable y empiece el proceso de pesaje nuevamente 4 Confiera el peso con un valor de peso sabido display muestra OL La carga en la balanza excede su capacidad Remueva el peso excesivo y use la balanza sus limites display muestra
29. scale exceeds the capacity Remove the excess weight and use the scale according to its limits The display shows UL The scale is in under load condition Make sure the rubber mat is placed on the base The display shows LO BAT The batteries are low Replace batteries according to instructions CALIBRATION The modes are accessible by holding certain keys pressed after power up The keys must be pressed and held for at least three seconds Flowchart Key Action gt gt Alternate Display Press and hold at leastthree seconds Zero REWEIGH REWEIGH D REWEIGH Reweigh key ZERO key ON OFF key Turn on the scale display StArt 200 0 LB IMPORTANT Scale must be clear when calibrating Zero calibration 200 0 LB EXPLODED VIEW OF SCALE E 22 09 42 69 402 69 69 PARTS LIST Key No Part No Description Qty 1 3811201 0 RUBBER MAT 1 2 3811101 0 PLATFORM 1 3 3810601 0 COVER PLANE 4 SELF LOCK NUT M5 32 5 3811001 0 SCALE BASE ASSY 1 6 PHIL PAN HEAD SCREW NC6 1 4 2 7 2138302 0 JUNCTION BOX 5 8 400142 STRAIN RELIEF 1 9 1304201 0 LOAD CELL 4 10 3810001 0 RUBBER FOOT NC3 8 4 11 RUBBER WASHER 4 12 HEX SOCKET SCREW NC5 16 3 4 8 13 2005502 0 JUN BOX MAIN BOARD CABLE 1 14 2138803 0 FA
30. scale for any obvious damage wear and tear 2 Inspect AC adapter for cord cracking or fraying or for broken or bent prongs CLEANING Proper care and cleaning is essential to ensure a long life of accurate and effective operation Disconnect the scale from the AC power source 1 Clean all external surfaces with a clean damp cloth or tissue Mild soap and water solution may be used Dry with a clean soft cloth 2 Do not immerse the scale base or display assembly into cleaning or other liquid solution 3 Do not use Isopropyl Alcohol or other solutions to clean the display surface TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on Dead Battery Faulty electrical outlet Bad power supply Replace batteries Use a different outlet Replace adapter Questionable weight or the scale does not zero External object interfering with the scale The display did not show 70 0 before weighing 3 Scale is not placed ona stable surface 4 Scale is out of calibration a N Remove interfering object from the scale Remove animal zero the scale and begin weighing process again 3 Place the scale ona stable surface and begin weighing process again 4 Check weight with known weight value The display shows OL The load on the
31. tomatiquement sur piles 14 INSTALLATION 1 Placez les piles dans le support pr vu cet effet cf le paragraphe Remplacer les piles ci dessous 2 Branchez l adaptateur CA de l appareil au bloc d affichage et la source d alimentation 3 Appuyez sur l interrupteur Marche Arr t ON OFF pour allumer l appareil L cran de visualisation affichera la mention Start d marrage suivie de 0 0 4 Apr s accomplissement du test automatique L cran num rique doit afficher 0 0 A droite de l cran doit alors appara tre la mention LB Pour modifier la programmation par d faut de l unit de poids en kilogramme kg veuillez contacter notre Centre d Assistance Technique aux num ros 1 800 638 3722 ou 1 708 598 9100 5 Placez un poids ne d passant pas 600 Lb 270 Kg sur la balance v t rinaire L cran num rique doit maintenant clignoter lt jusqu ce que le calcul du poids soit termin 6 Appuyez sur la touche LBS KG pour s lectionner l unit de poids de votre choix kilogrammes ou livres 7 Appuyez sur la touche REWEIGH l cran num rique doit pr sent lire nouveau le poids de l objet pos sur le plateau 8 Retirez l objet du plateau L cran num rique doit encore afficher le poids de l objet en question 9 Appuyez sur la touche ZERO l cran num rique doit pr sent se remettre z ro 10 D connectez la balance de la sourc
32. ture du poids exacte v rifiez le bon fonctionnement de la bascule en appliquant la proc dure d crite dans ce manuel avant chaque utilisation Ne pas utiliser en pr sence de substances inflammables Le fonctionnement sous d autres tensions et fr quences que celles sp cifi es dans ce manuel est susceptible d endommager l appareil Si l indicateur LO BAT est actif remplacez les piles ou connectez d s que possible la balance une source d alimentation AC pour obtenir une lecture du poids exacte SPECIFICATIONS GENERALITES La balance v t rinaire mod le 2842KL utilise une technologie tr s sophistiqu e parmi les technologies de microprocesseur disponibles aujourd hui sur le march Chaque instrument de pr cision est con u pour donner la mesure exacte fiable et r p table du poids et pr sente des caract ristiques qui font de la pes e un processus simple rapide et pratique La mesure r elle du poids s effectue par l application d une technologie de pes e sp ciale sensible au mouvement de fa on d terminer le poids d un animal actif Le poids peut tre lu en livres ou en kilogrammes La balance est quip e d un tapis en caoutchouc sp cialement con u pour faciliter le nettoyage de l appareil La balance peut tre utilis e avec son adaptateur lectrique CA ou avec 6 piles C SPECIFICATIONS DE LA BALANCE VETERINAIRE Capacit et R solution 600 Lb x 0 2 Lb 270 Kg x 0 1 Kg Exigences lectr
33. za El display hasta que el peso del animal sea determinado 5 Si usted desea repesar sin sacar y colocar el animal en la balanza otra vez presione el bot n REWEIGH 6 Retire el animal de la balanza El display digital debera continuar mostrando el peso del animal hasta que el bot n REWEIGH o ZERO sea presionado NOTA Despu s de 2 minutos de inactividad la balanza se apaga para ahorrar energia Para reactivar la balanza presione bot n ON OFF MANTENIMIENTO GENERAL Esta secci n provee instrucciones para mantenimiento limpieza soluci n de problemas piezas reemplazables del operador para la Balanza Veterinaria Modelo 2842KL Otras operaciones de mantenimiento aparte de las descritas en esta secci n deben ser realizadas por el personal de servicio calificado MANTENIMIENTO Antes de usarla por primera vez y despu s de periodos sin usarla confiera la balanza para una operaci n y funci n apropiadas Si la balanza no operar correctamente refi rase personal de servicio calificado 1 Verifique el aspecto total de la balanza para saber si hay cualquier da o desgaste obvios 2 Inspeccione el cargador de CA para verificar cord n con grietas o corro do o para dientes quebrados o acodados LIMPIEZA Cuidado apropiado y limpieza son esenciales para asegurar una larga vida de operaci n exacta y eficaz Desconecte la balanza de la fuente de energ a CA 1 Limpie todas la
Download Pdf Manuals
Related Search
Related Contents
COLTS AND RANGERS Norma 1.2 Mode d`emploi Philips LED Bulb 8718291664260 GP83 Service Manual (EN) H6050D-R(5.0).cdr Samsung RL39THCIH Felhasználói kézikönyv AFG2021 Arbitrary Function Generator Programmer Manual Copyright © All rights reserved.
Failed to retrieve file