Home

ELCODIS.COM - ELECTRONIC COMPONENTS DISTRIBUTOR

image

Contents

1. Mounting The FlexPoint 10FL 2 can be individually wall mounted using a wall mounting kit rack mounted using a 5 position space saver shelf or inserted in a 14 position power redundant FlexPoint Powered Chassis When wall mounting or shelf mounting attach the power adapter unit When connecting the FlexPoint 10FL 2 at the end of a coax segment attach the coax cable directly into the FlexPoint s BNC coax connector When connect ing it along the coax line not at the end use a T connector to tap into the cable 12 Precaci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato 14 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Obj
2. 0 SN Black Box Corporation The World s Source for Cabling and Network Connectivity ee A MARCH 2001 LMC211A MM LMC211A SM LMC211A 13MM LMC211AE MM LMC211AE SM LMC211AE 13MM FlexPoint 10FL 2 CUSTOMER Order toll free in the U S Call 877 877 BBOX SUPPORT side US call 724 746 5500 INFORMATION FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Specification MH Protocol IEEE 802 3 lOBase FL 10Base 2 Em Interface Connectors Fiber Optic 1 ST Coax 1 BNC m Cable Types MM fiber 50 125 62 5 125 100 140 um SM fiber 9 125 um 10Base 2 Coax 50 ohm RG 58A U RG 58C U RG 58 U or equivalent Supported Distances MM 850 nm fiber 2km 1 2mi 6 560 ft MM 1310 nm fiber 2km 1 2mi 6 560 ft SM 1310 nm fiber 2km 1 2 mi 6 560 ft l0Base 2 Coax 185 m 606 ft E Power 9 VDC 600 mA Physical Environmental Dimensions Weight W 3 0 xD 4 0 xH 1 0 2 lb Temperature 0 to 40 degrees C Humidity 0 90 non condensing Overview and Description The FlexPoint family of Converters supports the IEEE 802 3 and Ethernet Versions 1 0 2 0 standards They convert among 10Base FL fiber 10Base 2 thin coax and 10Base T twisted pair UTP media types The FlexPoint 10FL 2 converts from 10Base FL fiber to 10Base 2 co
3. When wall mounting or shelf mounting attach the power adapter unit When connecting the FlexPoint 10FL 2 at the end of a coax segment attach the coax cable directly into the FlexPoints BNC coax connector When connect ing it along the coax line not at the end use a T connector to tap into the cable NORMAS OFICIALES MEXICANAS NOM ELECTRICAL SAFETY STATEMENT 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas 4 Todas las instrucciones de operaci n y uso deben se 5 El aparato el ctrico no deber ser usado cerca del a ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc 6 El aparato el ctrico debe ser usado nicamente con carritos o pedelstales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de Todo otro servicio deber ser referido a personal de lificado 9 El aparato el ctrico debe ser situado de tal manera que su n no interfiera su uso La colocaci n del aparat
4. aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado 9 El aparato el ctrico debe ser situado de tal manera que su p n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama alfombra or superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u ostros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico deber ser conectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato Installation and Configuration Power Adapter Notice 1 When used in a stand alone configuration this product is intended to be used only with a Listed Direct Plug In Power Unit marked Class 2 and rated at 9Vdc 1 Amp 2 This product should always be used only with its enclosed Power Unit WARNING Before plugging the Power Adapter to any wall outlet or AC power source verify that the power on the unit is appropriate for your AC line voltage source
5. fiber and a BNC coax connector The following models are described here Model Fiber Type LM211A MM 850 nm Multimode LM211A SM 1310 nm Single mode LM211A 13MM 1310 nm Multimode LM211AE MM 850 nm Multimode LM211AE SM 1310 nm Single mode LM211AE 13MM 1310 nm Multimode The 10FL 2 provides a switch selectable 50 ohm termi nation that allows easy termination of the coax cable This function should be used only when the FlexPoint is connected at the end of a segment Note that the total length of the coax cable must not exceed 185 meters 606 ft and the number of sta tions on the coax segment must not exceed 30 sta tions per IEEE 802 3 specification Downloaded from Elcodis com electronic components distributor NORMAS OFICIALES MEXICANAS NOM ELECTRICALSAFETY STATEMENT 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas 4 Todas las instrucciones de operaci n y uso deben ser seguidas 5 El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc trico debe ser usado nicamente con carritos o les que sean recomendados por el fabricante 7 El
6. ax lt uses ST fiber and a BNC coax connector The following models are described here Model Fiber Type LM211A MM 850 nm Multimode LM211A SM 1310 nm Single mode LM211A 13MM 1310 nm Multimode LM211AE MM 850 nm Multimode LM211AE SM 1310 nm Single mode LM211AE 13MM 1310 nm Multimode The 10FL 2 provides a switch selectable 50 ohm termi nation that allows easy termination of the coax cable This function should be used only when the FlexPoint is connected at the end of a segment Note that the total length of the coax cable must not exceed 185 meters 606 ft and the number of sta tions on the coax segment must not exceed 30 sta tions per IEEE 802 3 specification Downloaded from Elcodis com electronic components distributor Installation and Configuration Power Adapter Notice 1 When used in a stand alone configuration this product is intended to be used only with a Listed Direct Plug In Power Unit marked Class 2 and rated at 9Vdc 1 Amp 2 This product should always be used only with its enclosed Power Unit WARNING Before plugging the Power Adapter to any wall outlet or AC power source verify that the power on the unit is appropriate for your AC line voltage source Mounting The FlexPoint 10FL 2 can be individually wall mounted using a wall mounting kit rack mounted using a 5 position space saver shelf or inserted in a 14 position power redundant FlexPoint Powered Chassis
7. ectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempe o o E El aparto ha sido tirado o su cubierta ha sido da ada Attach the fiber cables to the FlexPoint s connectors The FlexPoint s transmit Tx must attach to the re ceive side on the device at the far end of the fiber and the receive Rx must attach to the transmit side Switch Settings Termination switch When attaching anywhere along a coax cable except at the end the Termination switch should be set to Termination Out factory setting When attaching to the end of a cable it can be set to Termination In Note that when the switch is set to Termination In an external termination must not be attached LED indicators LED Color Description Power On Yellow Power applied Jabber Red Jabber condition Fiber Link Green Operational device detected at the far end of fiber Fiber Rx Green Received data on fiber line Coax Rx Green Received data on coax line Collision Yellow Collision detected OCopyright 1999 2001 Black Box Corporation All rights reserved 1000 Park Drive e Lawrence PA 15055 1018 724 746 5500 e Fax 724 746 0746
8. ght 1999 2001 Black Box Corporation All rights reserved 1000 Park Drive e Lawrence PA 15055 1018 724 746 5500 e Fax 724 746 0746 12 Precaci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato 14 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar normalmente o muestra un cambio en su desempe o o E El aparto ha sido tirado o su cubierta ha sido da ada Specification E Protocol IEEE 802 3 lOBase FL 10Base 2 Em Interface Connectors Fiber Optic 1 ST Coax 1 BNC M_ Cable Types MM f
9. iber 50 125 62 5 125 100 140 um SM fiber 9 125 um l0Base 2 Coax 50 ohm RG 58A U RG 58C U RG 58 U or equivalent Supported Distances MM 850 nm fiber 2km 1 2 mi 6 560 ft MM 1310 nm fiber 2km 1 2 mi 6 560 ft SM 1310 nm fiber 2km 1 2 mi 6 560 ft l0Base 2 Coax 185 m 606 ft E Power 9 VDC 600 mA Physical Environmental Dimensions Weight Temperature Humidity 3 0 xD 4 0 xH 1 0 2 1b 0 to 40 degrees C 0 90 non condensing Black Box Corporation N The World s Source for Cabling and Network Connectivity O MARCH 2001 LMC211A MM LMC211A SM LMC211A 13MM LMC211AE MM LMC211AE SM LMC211AE 13MM FlexPoint 10FL 2 CUSTOMER Order toll free in the U S Call 877 877 BBOX SUPPORT utside U S call 724 746 5500 INFORMATION FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail infoC blackbox com TRADEMARKS All applied for and registered trademarks are the property of their respective owners FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates uses and can radiate radio frequency energy and if not installed and used properly thatis in strict accordance with the manufacturer s instructions may cause interference to radio com
10. munication It has been tested and found to comply with the limits fora Class A computing device in accordance with the specifications in subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to be cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num irques de las classe A prescrites dans le R glement sur le brouillage radio lectrique publi par le minist re des Communications du Canada Overview and Description The FlexPoint family of Converters supports the IEEE 802 3 and Ethernet Versions 1 0 2 0 standards They convert among 10Base FL fiber 10Base 2 thin coax and 10Base T twisted pair UTP media types The FlexPoint 10FL 2 converts from 10Base FL fiber to 10Base 2 coax lt uses ST
11. o ico sobre una cama sof alfombra or superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los o ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u ostros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico deber ser conectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato os de Attach the fiber cables to the FlexPoint s connectors The FlexPoint s transmit Tx must attach to the re ceive side on the device at the far end of the fiber and the receive Rx must attach to the transmit side Switch Settings Termination switch When attaching anywhere along a coax cable except at the end the Termination switch should be set to Termination Out factory setting When attaching to the end of a cable it can be set to Termination In Note that when the switch is set to Termination In an external termination must not be attached LED indicators LED Color Description Power On Yellow Power applied Jabber Red Jabber condition Fiber Link Green Operational device detected at the far end of fiber Fiber Rx Green Received data on fiber line Coax Rx Green Received data on coax line Collision Yellow Collision detected Copyri

Download Pdf Manuals

image

Related Search

Related Contents

  User Manual - Comkit Online  Instrucciones de uso / HOBBY Productos para el cuidado de las  SAVE VTR 300/B Installation and Service  CardioChek User Guide - Stat  1.製品安全に対する基本方針 2.体制整備及び取組について  JamaicaVM 6.2 User Manual  S12 Poliuretano Alifático 2comp suelos  

Copyright © All rights reserved.
Failed to retrieve file