Home
manual de colocación
Contents
1. Do not ever glue the tables at the machos The pieces may be joined with a hammer and a e LOPEZ PIGUEIRAS wooden wedge It is very important to start from the wall on a straight line If the wall is at a false square angle one will have to use wedges as a supplement to align the first row of tables The alignment will be checked every two rows with a 2 m aluminium ruler To place the table it will be necessary to lean the receptacle ae L pez Pigueiras S A EE Lg de Patarroa s n 27861 Covas Viveiro Lugo oa Instrucciones Tel 982 561 061 Fax 982 561 460 against the peg of the table that has already been placed then let the table fall smoothly and fit them both One must not drag adhesive along lest 1t emerge to the surface In any case take para la colocaci n de la tarima care to clean the leftover adhesive while the product is still fresh l Do not step on the pallet until 24 hours after the application ffig 5 www lopezpiguerras com e w barnizada SUBSEQUENT CONDTIONS OF THE VENUES lopecprguetras lopezprguerras com ese Once the pallet has been placed one must maintain the relative Ins truc Hons humidity of the air of the venue between 35 65 It is necessary for this purpose to control the opening of windows for fo r placement of the varnished the airing of the place and for maintaining the hygroscopic conditions of the wood MAINTENANCE INSTRUCTIONS The followin
2. META of the pallet respecting the 10 mm perimeter joint PE SISTEMA DE GOLOGACION ENCOLADO CON PISTOLA and never gluing the tongue and groove joint It is very important to start from the wall on a straight line If GUN GLUING SYSTEM the wall is at a false square angle one will have to use wedges as a supplement to align the first row of tables The alignment will be checked every two rows with a 2 m aluminium ruler To place the table it will be necessary to lean the receptacle against the peg of the table that has already been placed then let the table fall smoothly and fit them both One must not drag adhesive along so 1t does not emerge to the surface In any case take care to clean the leftover adhesive while the product is still fresh Do not step on the pallet until 24 hours after the application fig 3 SPREADER GLUING PLACEMENT SYSTEM The pallet may also be placed in the same way as traditionally used with large format parquet MATERIALS TO BE USED Adhesive for wooden floorings see manufacturer s instructions of use It is presented in cans weighing 10 20 kg according to __ the manufacturer Serrated spreader MODE OF USE l Spread the adhesive with the serrated spreader forming uniform kerbs over a thoroughly clean and vacuumed surface ng 4 2 Place the pallet over the kerbs slightly pressing on the table so as to establish perfect contact with the adhesive leaving a perimeter distance of 10mm
3. Se presenta en salchichones de 600ml para su aplicaci n con pistola L mina de polietileno espumado de espesor 3mm ranurada Pistola manual para salchich n de 600ml Boquilla con salida triangular para aplicar el adhesivo PREPARACION DEL SOPORTE El soporte puede ser de tipo cementoso cer mico madera No son v lidos los soportes de moqueta de tipo pl stico o con tratamientos bituminosos o asfalticos El soporte deber estar limpio aspirado seco y libre de grasas e impurezas La falta de planeidad m xima deber ser de 5mm de flecha m xima con regla de 2m en caso contrario se recomienda aplicar un mortero de nivelaci n Se recomienda utilizar una imprimaci n para consolidar el soporte regular la humedad y promover la adherencia MODO DE EMPLEO 1 Extender la l mina sobre el soporte sin sistema de fijaci n alguno fig 1 2 Aplicar el adhesivo en las ranuras La aplicaci n se realizar con la boquilla en posici n de 90 dejando un cord n de forma triangular de altura justo la salida de la boquilla fig 2 3 Colocaci n de la tarima respetando la junta perimetral de 10mm y nunca encolar el machihembrado Es muy importante partir en l nea recta desde la pared Si la pared esta a falso escuadro habr que suplementar con cu as para conseguir el alineado de la primera hilera de tablas Cada dos hileras se comprobar de nuevo la alineaci n con una regla de aluminio de 2m Para colocar la tabla s
4. de Investigaci n T cnica de las Industrias de la Madera CONDICIONES PREVIAS DE LOS LOCALES CON SOLERA TRADICIONAL Para colocar la tar ma el local debe cumplir las siguientes condiciones Tener instalados todos los cerramientos que eviten la entrada de humedades del exterior Los materiales de paredes y techos tendr n una humedad inferior al 2 5 Se mantendr la humedad relativa del local entre el 30 y el 65 Se colocar una barrera de vapor mediante una l mina de polietileno PE 200 de 0 2mm de espesor solapando los pliegos 20cm y subiendo en el per metro hasta el rodapi Las instalaciones de abastecimiento electricidad calefacci n sanitarios y de otros revestimientos y pinturas deben realizarse antes de la colocaci n de la tarima Para colocar la tarima la solera debe cumplir las siguientes condiciones El contenido de humedad de la solera ser inferior al 2 5 siempre medido a una profundidad de la mitad del espesor de la solera y en los lugares m s desfavorables orientaci n norte El grosor m nimo de las soleras de mortero de cemento ser de 3cm La planitud del soporte ser tal que la flecha m xima medida con una regla de 20cm sea inferior a lmm o medida con una regla de 2m sea inferior a 3mm CONDICIONES PREVIAS DE LOS LOCAEES CON SOLERA CALEFACCION RADIANTE Las condiciones adicionales que se deben dar para colocar una tarima sobre suelo radiante son El espesor de la sol
5. e debe apoyar la hembra sobre el macho de la tabla ya colocada dejar caer la tabla con suavidad y encajar No se debe arrastrar adhesivo para que ste no reborde a la superficie En todo caso tener la precauci n de limpiar los sobrantes de adhesivo mientras el producto se mantenga fresco No pisar la tar ma hasta pasadas 24 horas de la aplicaci n fig 3 SISTEMA DE COLOCACI N ENCOLADO CON ESP TULA La tarima de pegar se puede colocar tambi n de la misma forma que tradicionalmente se ha realizado la colocaci n de parquets erandes formatos MATERIALES A UTILIZAR Adhesivo para pavimentos de madera ver las instrucciones de utilizaci n del fabricante Se presenta en latas de 10 20 kg seg n fabricante Esp tula dentada MODO DE EMPLEO 1 Extender el adhesivo con la esp tula dentada formando cordones uniformes sobre la superficie totalmente limpia y aspirada fig 4 2 Colocar la tarima sobre los cordones presionando ligeramente la tabla para su perfecto contacto con el adhesivo dejando una distancia perimetral de 10mm No encolar nunca las tablas por los machos Las piezas se pueden unir utilizando un martillo y un tarugo de madera Es muy importante partir en l nea recta desde la pared Si la pared est a falso escuadro habr que suplementar con cu as para conseguir el alineado de la primera hilera de tablas Cada dos hileras se comprobar de nuevo la alineaci n con una regla de aluminio de 2m Para colocar la
6. era por encima de las tuber as de conducci n debe ser como m nimo de 30mm Obra totalmente cerrada y limpia incluso aspirada sin restos de grasas ni polvos El contenido de humedad de la solera ser inferior al 2 Se pueden seguir las siguientes indicaciones para el secado forzado de la solera utilizando el propio sistema de calefacci n radiante e Poner en marcha el sistema e ir subiendo la temperatura eradualmente unos 2 C diarios durante una semana hasta alcanzar el r gimen normal de temperatura del sistema e Mantener la solera una semana a esta temperatura e Reducir progresivamente la temperatura gradualmente unos 2 C diarios hasta el secado completo de la solera La tarima debe cumplir las siguientes especificaciones Espesor de tarima que se debe utilizar para una adecuada optimizaci n de la transmisi n calor fica es de entre 14mm y 21mm Se deben utilizar maderas estables poco nerviosas Se deben utilizar maderas de densidad mayor o igual a 550 kg m Colocar la tarima cuando la solera haya alcanzado la temperatura ambiente seg n el sistema de colocaci n encolado a esp tula CONDICIONES PREVIAS DE LOS LOCALES CON SUELOS CERAMICOS Las condiciones adicionales que se deben dar para colocar una tarima sobre un suelo cer mico terrazos plaquetas ya sean lisos brillantes rugosos r sticos son El suelo debe estar perfectamente aspirado muy limpio y seco Colocar la tarima seg
7. g processes are recommended for the cleaning and maintenance of the pallet For daily cleaning use the BONA CARE cleaner which has been especially created for varnished wooden floors It N J ESS effectively eliminates stains and dirt without leaving any marks SISTEMA DE COLOCACI N ENCOLADO CON ESP TULA or waste behind Prior to cleaning vacuum or sweep the floor o so as to remove dust and waste SPREADER GLUING PEACEMENT SYSTEM For in depth cleaning use the REEFRESHER BONA CARE refresher which revivifies the surface giving 1t a newly finished 4 E A appearance as well as continuous protection against wear Prior LZ A EE to cleaning vacuum or sweep the floor to eliminate dust and EOFS Prat a A waste First one must carry out the daily cleaning process so as to ensure that the floor is completely clean and dry before the refresher is applied The orbital floor sander and polisher SS BONA BUFFER used with a red scourer is recommended for this cleaning job Use the BONA CARE cleaner once again MN I WN with a clean mop to eliminate all dirt remains Once this is dry spread the refresher with a BONA MICROFIBER cleaning pad over small areas applying a thin and homogenous layer Let it dry for 2 hours If necessary apply a second refresher Instrucciones de colocaci n avaladas por coat Wait for 24 hours before floor can be used normally again Asociaci n
8. n el sistema de colocaci n que m s convenga CONDICIONES DE ALMACENAMIENTO DE LA TARIMA La tarima se mantendr en su envoltorio original hasta el momento de la colocaci n SISTEMA DE COLOCACI N CLAVADO Es el sistema tradicional de colocaci n por excelencia Se recomienda colocar un rastrel de madera de dureza media alta de ancho 30mm atornillado a la solera Se recomienda la distribuci n de los rastreles paralela a la direcci n menor del recinto Se comprobar su paralelismo y nivelaci n Se colocar una l nea de rastreles como m ximo a l0cm de las paredes La separaci n m xima entre rastreles ser de 35cm para tarima de espesor 17 19mm 45cm para tarima de espesor 21mm Es recomendable rellenar el espacio entre rastreles con aislantes tipo planchas de poliestireno expandido fibra de vidrio o lana de roca La tabla se clava sobre el macho normalmente con clavadoras autom ticas con un ngulo de inclinaci n de 45 Se recomienda la utilizaci n de clavos de hierro de 1 4x40mm stos penetrar n en el rastrel como m nimo 20mm Se dejar desde la tarima hasta la pared una junta perimetral del 0 15 de la anchura del entablado siendo como m nimo de 10mm Se desaconseja totalmente encolar los machos que provocar a un efecto de mermas acumuladas SISTEMA DE COLOCACI N ENCOLADO CON PISTOLA MATERIALES A UTILIZAR Adhesivo para pavimentos de madera ver las instrucciones de utilizaci n del fabricante
9. re according to the spreader gluing placement system PREVIOUS CONDITIONS OF VENUES WITH CERAMIC FEOORS The additional conditions to be met for placing a pallet on a ceramic floor terrazzos shingles whether smooth glossy rough rustic are The floor must have been thoroughly vacuumed very clean and very dry Place the pallet according to the most convenient placement system PALLET STORAGE CONDITIONS The pallet will remain in its original wrapping until it is placed NAILING PLACEMENT SYSTEM This is the traditional placement system par excellence It is advisable to place a wooden fillet of medium high hardness and a width of 50 mm screwed onto the girder It is advisable to distribute the fillets in parallel to the lower direction of the room Their parallelism and levelling will be checked A line of fillets will be placed at 10 cm the most from the walls The maximum separation between the fillets will be of 35 cm for a pallet with a 17 19 mm thickness 45 cm for a pallet with a 17 19 mm thickness It is advisable to fill the space between the fillets with insulators such as expanded polystyrene sheets fibreglass or kaolin wool The table will be nailed onto the peg normally with automatic nailers with an inclination angle of 45 It is advisable to use iron nails of 1 4 x 40 mm These will sink at least 20mm into the fillets A perimeter joint of 0 15 of the width of the skirting board measuring a
10. t least 10 mm will be left between the pallet and the wall It is completely unadvisable to glue the pegs which would lead to an effect of accumulated losses GUN GLUING SYSTEM MATERIALS TO BE USED Adhesive for wooden floorings see manufacturer s instructions of use It is presented in 600 ml fascines to be applied with a gun Foamed polyethylene sheets with a 3 mm thickness and grooved Manual gun for application of 600 ml fascine Nozzle with triangular outlet for applying the adhesive PREPARATION OF THE SUPPORT The support may be cementitious ceramic wooden Fitted carpet supports are not valid as neither are plastic type ones or those with bituminous or asphaltic treatments The support will have to be clean vacuumed dry and free of grease and impurities The maximum lack of flatness will have to be a displacement of 5mm with a 2 cm rule If this be otherwise mortar levelling is recommended It is advisable to use a priming to consolidate the support regulate humidity and enhance adherence MODE OF USE I Spread the sheet over the support without any type of fixation fig 1 2 Apply the adhesive onto the slots Application will be carried out with the nozzle at a 90 position leaving a triangular kerb right at the outlet of the nozzle fig 2
11. t unfavourable places oriented to the north The minimum thickness of the cement mortar girders will be of 3 cm The flatness of the support will be such that the maximum displacement measured with a 20 cm ruler will be of less than 1 mm or of less than 5 mm if measured with a 2 m ruler PREVIOUS CONDITIONS OF VENUES WITH A GIRDER WITH RADIATING HEATING The additional conditions that must be met for placing a pallet on a radiating floor are the following The thickness of the girder above the conduction pipes must be of at least 30 mm The work must be absolutely closed and clean without any dust or grease The humidity content will have to be of less than 2 The following indications may be followed for the forced drying of the girder using the actual radiating heating system e Putting the system on and raising the temperature some 2 C a day for a week until the normal temperature regime of the system 1s reached e Maintaining the girder at this temperature for a week e Progressively reducing the temperature about 2 C a day until the girder is completely dry The pallet must meet the following specifications The thickness of the pallet to be used for an adequate optimisation of the heat transmission should be of between 14 mm and 21 mm One must use stable not too nervous wood One must use wood with a density of 550 kg m or more Place the pallet once the girder has reached ambient temperatu
12. tabla se debe apoyar la hembra sobre el macho de la tabla ya colocada dejar caer la tabla con suavidad y encajar No se debe arrastrar adhesivo para que ste no reborde a la superficie En todo caso tener la precauci n de limpiar los sobrantes de adhesivo mientras el producto se mantenga fresco No pisar la tarima hasta pasadas 24 horas de la aplicaci n ffig 5 CONDICIONES POSTERIORES DE LOS LOCALES Se debe mantener la humedad relativa del aire del local una vez colocada la tarima entre el 35 65 Para ello es necesaria la apertura controlada de ventanas para la aireaci n del local y mantenimiento de las condiciones higrosc picas de la madera INSTRUCCIONES DE MANTENIMIENTO Se recomienda para la limpieza y mantenimiento de la tarima los siguientes procesos Para la limpieza diaria utilizar el limpiador BONA CARE desarrollado especialmente para suelos de madera barnizados Elimina de forma efectiva las manchas y suciedad sin dejar marcas o residuos Antes de limpiar aspirar o barrer el suelo para quitar el polvo y residuos Para la limpieza en profundidad utilizar el restaurador REFRESHER BONA CARE Reaviva la superficie proporcionando un aspecto reci n acabado y una continua protecci n contra el desgaste Antes de limpiar aspirar o barrer el suelo para quitar el polvo y residuos Se realizar primero la limpieza diaria asegur ndose de que el suelo esta completamente limpio y seco antes de aplicar el resta
13. urador Se recomienda utilizar una maquina orbital BONA BUFFER con estropajo rojo para realizar esta limpieza Utilizar de nuevo el limpiador BONA CARE con una mopa limpia para eliminar todos los restos de suciedad Una vez seco extender el restaurador con una almohadilla BONA MICROFIBER en zonas peque as aplicando una capa fina y homog nea Dejar secar unas 2 horas En caso necesario aplicar una segunda mano de restaurador Esperar 24 horas para el uso normal del suelo PREVIOUS CONDITIONS OF THE VENUES WITH A TRADITIONAL GIRDER In order to place the pallet the venue must meet the following conditions All the closures needed for preventing the entrance of humidity from the outside The materials of walls and ceilings having a humidity of less tan 23 The relative humidity of the establishment remaining at a level of between 30 and 65 A steam barrier will be placed by means of a PE 200 polyethylene plate with a thickness of 0 2 mm the folds overlapping about 20 cm and raising in the perimeter up to the skirting board The installations related to supply electricity heating bathroom installations as well as other coatings and paint jobs will have to be done before the pallet is placed In order to place the pallet the girder will have to meet the following conditions The humidity content of the girder will have to be of less than 2 5 always at a depth of half of the thickness of the girder and in the mos