Home
Submersible Sump Pumps
Contents
1. 6 Suggested Part Replacement Schedule 1 14 4 6 Service and Repair dE ed ed Sea o he 6 Troubleshooting EE 7 Lifetime Warranty Back Cover ii Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID SP 330 SP 330D SP 500 amp SSP 1000 Submersible Sump Pumps SP 330 SP 330D SP 500 and SSP 1000 Submersible Sump Pumps Record Serial Number From Product Decal Below Serial No 351405 005 8 06 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EE DS E UT TUE General Safety Information Safety is a combination of common sense staying alert and understanding how your sump pump works Safety Signal Words ADANGER means if the safety information is not followed someone will be seriously injured or killed AAWARNING means if safety information is not fol lowed someone could be seriously injured or killed ACAUTION means if safety information is not fol lowed someone may be injured NOTICE indicates important information that if not followed may cause damage to the equipment or flooding AAWARNING Read and understand all instruc tions Failure to follow all instructions listed belo
2. Service AWARNING The motor is oil filled and sealed for cooler run ning Allow 2 hours for the motor to cool before servicing Hot oil is under pressure and could result in severe burns Pump service must be performed only by qual ified repair personnel Service or maintenance performed by unqualified repair personnel could result in injury and may void the warranty When servicing a pump use only identical replacement parts Follow instructions in the Maintenance Section of this manual Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electrical shock or injury NOTE Disassembly of the motor will void warranty Specific Safety Information AWARNING Risk of electric shock This pump is supplied with a grounding type plug To reduce risk of electric shock be certain that it is connect ed only to a properly grounded grounding type receptacle that is protected by a GFCI For your own safety before assembling and operating this unit read this operators manual carefully and com pletely Learn the operation application and potential hazards peculiar to this unit Call the Ridge Tool Company Technical Services Department at 800 519 3456 if you have any ques tions Submersible Pump Safety ADANGER e Do not use to pump flammable or explosive flu ids such as gasoline fuel oil kerosene sol vents thinners etc Do not use in a flamm
3. AAWARNING when routing electrical cord protect cord from sharp objects hot surfaces oils and chemi cals Do not kink or tightly clamp cord replace any damaged cord immediately Ridge Tool Company 5 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID FERME ETS Testing 1 Fill sump pit with water 2 While the pump is draining the pit verify that the discharge piping is carrying the water to a point at least 15 feet away from the foundation NOTICE The outside piping must be tilted downward to drain This helps prevent debris from entering the discharge pipe and also prevents trapped water from freezing which can damage the pump 3 Install sump pit cover not included to prevent debris from clogging or damaging the pump Maintenance Instructions AWARNING Always disconnect the electrical supply or unplug the pump before attempting to install service relocate or perform any maintenance If the power source is out of sight lock and tag in the open OFF position to prevent unex pected power application Failure to do so could result in fatal electrical shock Only a qualified technician should repair this unit Improper repair could result in fatal electrical shock The motor is oil filled and sealed for cooler running Allow 2 hours for motor to cool before servicing Hot oil under pressure could result in severe burns _
4. When servicing this pump only identical replace ment parts should be used Failure to follow these steps may create a risk of flooding property dam age fatal electrical shock or other serious injury and may also void your warranty If you have any questions regarding the service or repair of this machine call or write to Ridge Tool Company Technical Service Department 400 Clark Street Elyria Ohio 44036 2023 Tel 800 519 3456 E Mail TechService ridgid com For name and address of your nearest Independent Authorized Service Center contact the Ridge Tool Company at 800 519 3456 or http www ridgid com For Customer Support call 1 877 9RIDGID 6 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID 5 330 5 3300 5 500 55 1000 Troubleshooting AWARNING Let the pump cool for a minimum of two hours before servicing because the pump contains hot oil under pressure Disconnect pump from power source before servicing TROUBLESHOOTING CHART Symptom Possible Cause s Corrective Action Pump will not start or run 1 Blown fuse or breaker 1 If blown replace with proper sized fuse or reset breaker 2 Low line voltage 2 If voltage is under 108 volts check wiring size 3 Worn motor 3 Replace motor or pump 4 Worn switch 4 Replace switch 5 Impeller
5. 1000 D charge m tres 0 1000 2000 3000 4000 5000 6000 Litres par heure Courbe de performance Tableau de performance Mod le T te de d charge Om 1 5 3 1m 4 6m SP 330 Litres heure 11734 11355 10220 6359 SP 330D Litres heure 11734 11355 10220 6359 SP 500 Litres heure 16654 15519 12112 7570 SSP 1000 Litres heure 20439 18395 15897 12718 Installation de la pompe Ae ADANGER La pompe ne doit servir que pour pomper de l eau claire Ne Putilisez pas pour des fluides tels qu essence fuel ou k ros ne ni dans une atmosph re inflammable ou explosive Toute mauvaise utilisation de la pompe pourrait causer des blessures et ou la mort AAVERTISSEMENT Pour viter les dommages la propri t les blessures graves ou la mort il faut installer la pompe correctement et suivre ces proc dures La pompe doit tre branch e dans une prise qui inclut un disjoncteur diff rentiel DD Figure 1 Coupez toujours la source de courant avant d essayer d installer de r parer de replacer ou de faire l entretien de la pompe Ne manipulez jamais une pompe ou son moteur avec les mains mouill es ou debout sur une surface mouill e ou humide ou dans l eau Installation 1 Construisez une fosse de puisard en b ton acier ou plastique d une profondeur de 24 po 60 96 cm et d au moins 11 po 27 94 cm de diam tre Figure 2 S il y a d j un puisard assurez vous qu
6. DESH GION a a A aide nigel A A an 20 rt a H Saad Som od Gb Sa e Ar 21 Curva de rendimiento y tabla de rendimiento 21 Instalaci n de la bomba EA PP SN 21 22 Pruebas cui de ala E E E aa a a net A E 23 Instrucciones de mantenimiento 23 Programa recomendado para el recambio de 2 23 Servicio y reparaci n 2 9 eus ek eee o Et av ee Da e aara 23 Correcci n de fallas sage Sa Mer pakke da a Pe a ee dae oe ee 24 Garant a de por vida Contraportada 18 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID ETOILES TRS Informacion general de seguridad La seguridad es una combinaci n de sentido com n mantenerse alerta y comprender c mo funciona su bomba de sumidero Palabras de se ales de seguridad APELIGRO significa que si no se sigue la informaci n de seguridad alguien sufrir graves lesiones o la muerte AADVERTENCIA significa que si no se sigue la informaci n de seguridad alguien podr a sufrir graves lesiones o la muerte APRECAUCION significa que si no se sigue la informacion de
7. Les outils RIDGE sont garantis contre tous vices de mat riaux et de main d oeuvre Dur e de couverture Cette garantie est applicable durant la vie enti re de l outil RIDGE La couverture cesse d s lors que le produit devient inutilisable pour raisons autres que des vices de mat riaux ou de main d oeuvre Pour invoquer la garantie Pour toutes r parations au titre de la garantie il convient d exp dier le produit complet en port pay la RIDGE TOOL COMPANY Elyria Ohio ou bien le remettre un r parateur RIDGID agr Les cl s pipe et autres outils main doivent tre ramen s au lieu d achat Ce que nous ferons pour r soudre le probl me Les produits sous garantie seront la discr tion de RIDGE TOOL soit r par s ou remplac s puis r exp di s gratuitement ou si apr s trois tentatives de r paration ou de remplacement durant la p riode de validit de la garantie le produit s av re toujours d fectueux vous aurez l option de demander le remboursement int gral de son prix d achat Ce qui n est pas couvert Les d faillances dues au mauvais emploi l abus ou l usure normale ne sont pas couvertes par cette garantie RIDGE TOOL ne sera tenue responsable d aucuns dommages directs ou indirects L influence de la l gislation locale sur la garantie Puisque certaines l gislations locales interdisent l exclusion des dommages directs ou indirects il se peut que la limitation ou exclusion ci dessus ne vous
8. de l nea 1 Si el voltaje est por eg de 108 voltios revise el calibre del cable suministra poca onaga de agua 2 Rotor taponado 2 Limpie el rotor Figura Descripci n Cat RIDGID Cat RIDGID Cat RIDGID Cat RIDGID SP330 SP330D SP500 SSP 1000 1 Kit de flotaci n 88557 N A 88557 N A 2 Interruptor Conjunto superior 88562 N A 88562 25138 2a Conjunto superior diafragma N A 88567 N A N A 2b Sensor de agua de estado s lido N A N A N A 25143 3 Estator 88577 88577 88582 25148 4 Soporte inferior Rotor 88587 88587 88592 25153 5 Rotor de hierro fundido 88597 88597 88597 25158 6 Voluta de hierro fundido 88602 90382 88602 88602 24 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EEE EE TE TN Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf 25 FULL LIFETIME WARRANTY What is covered RIDGID tools are warranted to be free of defects in workmanship and material How long coverage lasts This warranty lasts for the lifetime of the RIDGID tool Warranty coverage ends when the product becomes unusable for reasons other than defects in workmanship or material How you can get service To obtain the benefit of this warranty deliver via prepaid transportation the complete product to RIDGE TOOL COMPANY Elyria Ohio or any
9. est dise ada para funcionar en sumideros dom sticos nicamente La unidad est equipada con un cord n el ctrico de 8 pies de largo 2 4 m con tres espigas y puesta a tierra El motor tiene un protector t rmico de reposici n autom tica para prevenir la quemadura del motor debido a sobrecargas u obstrucciones Un interruptor flotante proporciona operaci n autom tica para mantener el nivel del agua entre los puntos preajustados de f brica La bomba est dise ada para mantener el nivel del agua entre los puntos preajustados de f brica La SSP 1000 trae un control electr nico de estado s lido para el nivel de agua La bomba se enciende autom ticamente cuando se detecta la presencia de agua AVISO Esta bomba est dise ada para manejar agua salada salmuera descargas de lavander a u otras aplicaciones que puedan contener agentes qu micos c usticos y o materiales extra os 20 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EEE EE TE TNT Esta bomba no es adecuada para su uso con fauna acuatica La bomba puede dafarse o averiarse si se usa en estas aplicaciones y esto causar la anulaci n de la garant a AVISO Se recomienda ampliamente usar un sistema de pila de reserva Las suspensiones del servicio el ctrico el flujo excesivo del agua el disparo del interruptor G F C I y el desgaste de la bomba primaria pueden cau
10. realizadas por personal calificado de reparaciones La bomba debe llevarse a un Centro Autorizado de Servicio RIDGID independiente o enviarse a la f brica Todas las reparaciones realizadas en los centros de servicio RIDGID est n garantizadas contra defectos en materiales y mano de obra Al dar mantenimiento a esta bomba s lo deben usarse piezas id nticas de repuesto marca RIDGID Si no se respetan estas advertencias habr riesgos de inundaciones da os materiales descargas el ctricas fatales u otras graves lesiones y tambi n puede causar la p rdida de la garant a Si usted tiene alguna pregunta respecto al servicio reparaci n de esta m quina llame o escriba a Ridge Tool Company Technical Service Department 400 Clark Street Elyria Ohio 44036 2023 Tel 800 519 3456 E Mail TechService Oridgid com Si desea conocer el nombre y la direcci n del Centro Autorizado de Servicio independiente m s cercano a su domicilio comun quese con Ridge Tool Company llamando al 800 519 3456 o visite nuestra p gina de Internet en http www ridgid com Para Asistencia al Cliente llame al 1 877 9RIDGIG Ridge Tool Company 23 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441_347927 paf RIDGID EL EE mets TT Correcci n de fallas ADVERTENCIA Permita que la bomba se enfr e durante dos horas como m nimo antes de repararla o darle mantenimiento porqu
11. 3000 4000 5000 6000 Gallons Per Hour Performance Chart Discharge Head 0 5 10 15 SP 330 Gallons Hour 3100 3000 2700 1680 SP 330D Gallons Hour 3100 3000 2700 1680 SP 500 Gallons Hour 4400 4100 3200 2000 SSP 1000 Gallons Hour 5400 4860 4200 3360 Pump Installation ADANGER Pump should only be used to pump clear water Do not use to pump fluids such as gaso line fuel oil or kerosene Do not use in a flam mable or explosive atmosphere Improper use could result in personal injury and or death AWARNING To prevent property damage serious injury or death proper installation of the pump is required The following procedures oe be followed Pump must be plugged into an outlet recepta cle that includes a Ground Fault Circuit Interrupter GFCI Figure 1 Always disconnect the power source before attempting to install service relocate or main tain the pump Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water Installation 1 Construct a sump pit from concrete steel or plas tic that is 24 deep and at least 11 in diameter Figure 2 If the sump already exists make sure it is the proper size Figure 2 Submersible Pump Installation 2 Make sure the electrical outlet is grounded and is rated for 115 volts and at least 15 amps The out let must be protected by a Ground Fault Circuit Interrupter GFCI AWARNING Use of a grounded re
12. A 13 14 TESUNO coito Zog feet pense ne dos de otre eme bi ehh De Mid anh 15 Instructions d entretien 15 Suggestions d horaire de remplacement des pi ces 15 Service et r paration EEN EEN ENN ERAN e ue 15 D pannage ear Se Matas eee atte aera 16 Garantie vie EE EEN NN EEN EEN NN eee de a ee eee Couverture arri re 10 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID 330 IS Informations g n rales de s curit La s curit est un m lange de sens commun vigilance et compr hension du fonctionnement de votre pompe de puisard Termes de s curit ADANGER signifie que si l information de s curit n est pas respect e une personne sera gri vement bless e ou tu e AVERTISSEMENT signifie que si l information de s curit n est pas respect e une personne pourrait tre gri vement bless e ou tu e ATTENTION signifie que si l information de s curit n est pas respect e une personne pourrait tre bless e AVIS indique de l information importante qui non respect e pourrait endommager l quipement ou inonder AVERTISSEMENT Lire et comprendre toutes l
13. Check the operation of the Ground Fault Circuit Interrupter on a monthly basis 2 Keep pump inlet clean and free of all foreign objects Inspect at least once a year and clean sump as needed 3 Check pump for proper operation monthly by filling sump with water until pump turns on 4 Inspect all plumbing connections for any leaks or looseness monthly SSP 1000 Solid State Water Sensor only 5 Pump can be checked for proper operation by briefly removing pump power cord from the back of the Solid State Water Sensor plug and inserting directly into the grounded outlet In this condition the pump will run continuously Once pump opera tion is verified replace pump power cord into the back of the Solid State Water Sensor plug see Figure 4 NOTE Disassembly of the motor will void the warranty Suggested Part Replacement Schedule Replace pump switch every 2 years See page 8 for Ridgid catalog Replace float every 2 years See page 8 for Ridgid catalog SSP 1000 uses a solid state electronic control with no moving parts see Figure 4 therefore replacement is not needed Service And Repair AWARNING Service and repair work on this pump must be per formed by qualified repair personnel Pump should be taken to a RIDGID Independent Authorized Service Center or returned to the factory All repairs made by Ridge service facilities are war ranted against defects in material and workman ship
14. N A N A 2b D tecteur d eau a tat solide N A N A N A 25143 3 Inducteur 88577 88577 88582 25148 4 Fixation inducteur inf rieur 88587 88587 88592 25153 5 Rotor en fer forg 88597 88597 88597 25158 6 Volute de fer forg 88602 90382 88602 88602 16 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID Bombas sumergibles de sumidero SP 330 SP 330D SP 500 y SSP 1000 Bombas sumergibles de sumidero SP 330 SP 330D SP 500 y SSP 1000 Anote el Numero de serie indicado abajo en la calcomania del producto No de serie 351405 005 8 06 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EEE EE EE eT Indice Formulario de registro para el numero de serie de la bomba 17 Informacion general sobre seguridad een ee ee eee ee en ee ae eee eee eee 19 Seguridad el ctrica os cs ee Teraa Le we eave fa sphere ist 19 Seguridad 19 Mantenimiento y reparaci n 2 20 Informacion especifica sobre seguridad Aspectos de seguridad de la bomba sumergible 20 Descripci n y especificaciones
15. a o humedad en el piso el suelo cerca de la bomba no camine sobre el rea h meda hasta que se haya desconectado todo el suministro el ctrico Si la caja de desconexi n est en el s tano llame a un electricista Si no sigue esta advertencia podr an producirse graves descargas el ctricas Desconecte siempre la fuente de alimentaci n el ctrica antes de intentar instalar reparar reubicar o dar mantenimiento a la bomba Nunca maneje una bomba o un motor de bomba con las manos h medas o parado sobre una superficie h meda o mojada o en el agua Si no se respeta esta advertencia podr an ocurrir graves lesiones personales o la muerte El motor de la bomba est equipado con un protector t rmico de reposici n autom tica que puede causar la reactivaci n inesperada del equipo Desconecte la fuente de suministro el ctrico cuando vaya a reparar la bomba No modifique ni coloque el interruptor flotante de modo que la bomba funcione continuamente Esta bomba no est dise ada para funcionar continuamente y por tanto esto reducir su rendimiento y la vida til de la bomba No cuelgue la bomba por el mango como instalaci n permanente La bomba debe apoyarse firmemente sobre sus patas y debe quedar soportada por la tuber a r gida Con esto se reducen al m nimo las torceduras que pueden provocar da os durante el funcionamiento de la bomba Descripci n y especificaciones Descripci n Esta bomba sumergible
16. able and or explosive atmosphere Pump should only be used to pump clear water Improper use could result in personal injury and or death AWARNING If there is water or moisture on the floor or Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf ground near the pump do not walk on wet area until all power is turned off If the shut off box is in the basement call an electrician Failure to follow this warning could result in fatal electrical shock Always disconnect the power source before attempting to install service relocate or main tain the pump Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water Failure to follow this warning could result in personal injury and or death Pump motor is equipped with automatic reset ting thermal protector that could restart unex pectedly Disconnect power source when servic ing pump Do not modify float or position float switch so that pump will operate continuously Pump is not designed for continuous operation this will reduce performance and life of the pump Do not hang pump by handle for permanent installation This minimizes twisting which can lead to damage during pump operations Description and Specifications Description The submersible pump is designed for home sump operations only The unit is equipped with an 8 foot 3 prong grounding t
17. ado o sustituido tres veces durante el per odo de su garant a Ud puede optar por recibir un reembolso por el valor total de su Compra Lo que no est cubierto Esta garant a no cubre fallas debido al mal uso abuso o desgaste normal RIDGE TOOL no se hace responsable de da o incidental o consiguiente alguno Relaci n entre la garant a y las leyes locales Algunos estados de los EE UU no permiten la exclusi n o restricci n referente a da os incidentales o consiguientes Por lo tanto puede que la limitaci n o restricci n mencionada anteriormente no rija para Ud Esta garant a le otorga derechos espec ficos y puede que adem s Ud tenga otros derechos los cuales var an de estado a estado provincia a provincia 0 pais a pa s No rige ninguna otra garant a expresa Esta GARANTIA VITALICIA es la nica y exclusiva garant a para los productos RIDGID Ning n empleado agente distribuidor u otra persona est autorizado para modificar esta garant a u ofrecer cualquier otra garant a en nombre de RIDGE TOOL COMPANY 351405 005 8 06 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441_347927 paf
18. ales 7 Esta bomba tiene una tuber a de descarga de 1 1 2 NPT Si la tuber a existente tiene 1 1 4 NPT es posible usar un buje o manguito adaptador que no se incluye con la bomba No use una tuber a que tenga menos de 1 1 4 NPT Una tuber a demasiado peque a causar un rendimiento deficiente del TL San H i La superficie de trabajo del sensor debe mantenerse libre de material extra o Figura 4 Sensor de agua de estado solido 8 Se requiere una v lvula de retenci n que no se incluye con la bomba en la tuber a de descarga para impedir el reflujo al desactivar la bomba Es mejor instalar la v lvula de retenci n directamente en el punto de descarga de la bomba Enrosque una v lvula de retenci n en el punto de descarga de la bomba AVISO Tenga cuidado para no desgastar los filetes de la rosca o enroscar mal la v lvula No use un agente sellador para tuber as AVISO La finalidad del uso de la manguera flexible de descarga es nicamente temporal Para una instalaci n permanente se requiere el uso de un tubo r gido de PVC o metal Si se usa temporalmente una manguera flexible de descarga aseg rese de que la bomba est sujetada firmemente a la cuenca del sumidero para evitar movimientos La falta de una sujeci n firme de la bomba puede permitir el movimiento de la bomba y causar una interferencia en el interruptor evitando que la bomba se ponga en marcha
19. authorized RIDGID INDEPENDENT SERVICE CENTER Pipe wrenches and other hand tools should be returned to the place of purchase What we will do to correct problems Warranted products will be repaired or replaced at RIDGE TOOL S option and returned at no charge or if after three attempts to repair or replace during the warranty period the product is still defective you can elect to receive a full refund of your purchase price What is not covered Failures due to misuse abuse or normal wear and tear are not covered by this warranty RIDGE TOOL shall not be responsible for any incidental or consequential damages How local law relates to the warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may also have other rights which vary from state to state province to province or country to country No other express warranty applies This FULL LIFETIME WARRANTY is the sole and exclusive warranty for RIDGID products No employee agent dealer or other person is authorized to alter this warranty or make any other warranty on behalf of the RIDGE TOOL COMPANY Ridge Tool Company 400 Clark Street Elyria Ohio 44036 2023 Ridge Tool Subsidiary ES Emerson Electric Co KRIS EMIERSON SMS S Printed in U S A 8 06 FULL LIFETIME WARRANTY Ce qui est couvert
20. ceptacle that is protected by a GFCI reduces risk of a fatal electrical shock 3 Inspect the power cord and plug for damage If the plug is missing the grounding prong or the cord is damaged do not install the pump until the cord has been replaced 4 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID FEES SP 330D Diaphragm Switch only Remove the two fasteners in the cast iron volute near the discharge area Align the hole with the diaphragm switch and replace the fasteners with out over tightening Figure 3 Attach switch with screws 2 provided Figure 3 Diaphragm Switch AWARNING Never cut off grounding prong or use an adapter AWARNING Support pump and piping when assembling and after installation Failure to do so could cause piping to break or pump to fail which could result in property damage and or personal injury SSP 1000 Solid State Water Sensor only 5 Insert the pump power cord plug directly into the back of the Solid State Water Sensor cord plug Figure 4 Working surface of sensor to be kept free of foreign material Figure 4 Solid State Water Sensor 6 Set pump into sump Locate the pump on a solid level surface NOTICE Do not place directly on clay gravel or any loose or sandy surfaces These surfaces contain small stones or sand that may clog or damage the pump whi
21. ch could result in pump failure causing flood ing and property damage 7 This pump has a 1 1 2 NPT discharge If existing piping is 1 1 4 NPT an adapter bushing not included may be used Do not use piping that is less than 1 1 4 NPT Piping that is too small will result in reduced output 8 check valve is required in the discharge line to prevent backflow when the pump shuts off It is best to install the check valve directly to the pump dis charge Thread a check valve into pump discharge NOTICE Be careful not to strip or cross thread Do not use pipe joint sealant NOTICE Flexible discharge hose is intended for temporary use only Rigid PVC or metal pipe is required for a permanent installation If flexible dis charge hose is temporarily used make sure pump is secured in sump pit to prevent movement Failure to secure pump could allow pump movement and cause switch interference and prevent pump from starting or stopping This could result in flooding and property damage IMPORTANT Make sure there is adequate room for float switch to move freely during operation A 1 minimum is required 9 Connect 1 1 4 diameter rigid pipe to rubber boot on check valve not included Reverse boot for 1 1 2 diameter pipe Tighten clamps 10 Insert the pump cord plug directly into 115 volt grounded electrical outlet that is protected by Ground Fault Circuit Interrupter GFCI Figure 1
22. drogas alcohol o medicamentos Un solo momento de descuido puede ocasionar graves lesiones personales e V stase correctamente No use ropas sueltas ni joyas Sujete el cabello largo Mantenga su cabello sus ropas y sus guantes lejos de las piezas m viles La ropa suelta las joyas o el cabello largo pueden quedar atrapados entre las piezas m viles No se estire excesivamente Mantenga un equilibrio apropiado con los pies bien firmes en el suelo Una buena postura de los pies y un buen equilibrio permiten tener un mejor control en situaciones inesperadas Use los equipos de seguridad Use siempre protecci n para los ojos Tambi n se deben usar zapatos antirresbalantes de seguridad mascarilla antipolvo y casco en las condiciones apropiadas Ridge Tool Company 19 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441_347927 paf RIDGID EEE Sp 2900 Sp TE TO Mantenimiento y reparaci n ADVERTENCIA El motor est lleno de aceite y herm ticamente cerrado para funcionar a menor temperatura Espere durante 2 horas para que el motor se enfr e antes de iniciar cualquier tarea de mantenimiento o reparaci n El aceite caliente est bajo presi n y puede ocasionar graves quemaduras El mantenimiento y la reparaci n de la bomba deben estar a cargo de personal calificado nicamente Si estas tareas son realizadas por personas inexpertas podr an ocurrir graves l
23. ducing the risk of seri ous injury or death from electrical shock Grounded Grounding Outlet Blade ee TEST RESET Se MH Cord Figure 1 Before using test the Ground Fault Circuit Interrupter GFCI to insure it is operating cor rectly GFCI reduces the risk of electrical shock Do not use an extension cord This increases the risk of electrical shock If necessary install a properly grounded outlet closer to the pump Personal Safety AWARNING Stay alert watch what you are doing and use common sense when installing this pump Do not attempt to install this pump while tired or under the influence of drugs alcohol or med ications A moment of inattention may result in serious personal injury Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts Do not overreach Keep proper footing and bal ance at all times Proper footing and balance enables better control in unexpected situations Use safety equipment Always wear eye protec tion Dust mask non skid safety shoes and hard hat must be used for appropriate conditions 2 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID 5 30 5 3300 5 500 55 1000
24. e la bomba contiene aceite caliente bajo presi n Desconecte la bomba de la fuente de suministro el ctrico antes de intentar cualquier reparaci n o mantenimiento CUADRO DE CORRECCI N DE FALLAS S ntoma Causa s posible s Medida correctiva La bomba no arranca ni funciona 1 Interruptor o fusible quemado 1 Si se quem el fusible reempl celo con un fusible de tama o apropiado o reajuste el interruptor 2 Bajo voltaje de l nea 2 Siel voltaje est por debajo de 108 voltios revise el calibre del cable 3 Motor desgastado 3 Reemplace el motor o la bomba 4 Interruptor desgastado 4 Reemplace el interruptor 5 El rotor no est girando 5 Si el rotor no gira retire la caja y elimine el bloqueo 6 Obstrucci n del flotante 6 Aseg rese que el flotador se mueva libre arriba y abajo La bomba arranca y se detiene 1 Reflujo del agua por la tuber a 1 Instale o reemplace la v lvula de retenci n con demasiada frecuencia 2 Interruptor defectuoso 2 Reemplace el interruptor La bomba no se apaga o el 1 Sensor de agua de estado 1 Limpie la superficie del sensor ver las etapas protector t rmico se abre s lido sucio Modelo del Mantenimiento SSP 1000 solamente 2 Interruptor defectuoso 2 Reemplace el interruptor 3 Obst culo en la tuber a 3 Retire la bomba y limpie la bomba y la tuber a 4 Flotante obstruido 4 Aseg rese que el flotador se mueva libre arriba y abajo La bomba funciona pero 1 Bajo voltaje
25. e surface mouill e ou humide ou dans l eau Le non respect de cet avertissement pourrait mener une blessure et ou la mort Le moteur de la pompe est dot d un protecteur thermique r initialisation automatique qui pourrait red marrer inopin ment Coupez toujours le courant en r parant la pompe Ne modifiez pas le flotteur ni l interrupteur de position du flotteur pour que la pompe fonctionne continuellement La pompe n est pas con ue pour fonctionner continuellement et ceci r duira sa performance et sa dur e de vie suspendez pas la pompe par la poign e pour une installation permanente Ceci minimise la torsion ce qui pourrait provoquer des dommages lorsque la pompe fonctionne Description et Sp cifications Description La pompe submersible est con ue pour les op rations de d cantation r sidentielle seulement L appareil est dot d un cordon mis la terre 3 broches de 8 pieds 2 4 m Le moteur a un protecteur thermique de r initialisation automatique pour pr venir les grillages suite des surcharges ou des blocages Un interrupteur activ par flotteur fournit une op ration automatique pour conserver le niveau d eau entre les points pr tablis en usine La pompe est con ue pour maintenir automatiquement le niveau d eau entre les points pr r gl s lusine La pompe SSP 1000 est fournie avec un d tecteur de niveau d eau lectronique a tat solide La pompe se d marre aut
26. eado el ctrico debe ser realizada por un electricista calificado El cableado incorrecto puede acarrear descargas el ctricas fatales No maltrate el cord n Nunca use el cord n para transportar la bomba ni tire del cord n para desconectar el enchufe Mantenga el cord n lejos del calor aceite bordes cortantes o piezas m viles Reemplace inmediatamente los cordones da ados Los cordones da ados aumentan el peligro de descargas el ctricas La bomba debe conectarse a una toma de corriente que incluye un interruptor de circuito de tierra accidental GFCI En caso de fugas de corriente el interruptor GFCI se dispara reduciendo as el riesgo de graves lesiones o muerte por descargas el ctricas Espiga de puesta Toma con puesta a tierra a tierra M TEST RESET el ctrico Figura 1 Antes de usarlo pruebe el interruptor GFCI para asegurarse de que est funcionando correctamente Un interruptor GFCI reduce el riesgo de descargas el ctricas e No use un cord n de extensi n El cord n de extensi n aumenta el riesgo de descargas el ctricas De ser necesario instale una toma de corriente con una puesta correcta a tierra m s cerca de la bomba Seguridad personal AADVERTENCIA Mant ngase alerta atento lo que est haciendo y act e con sentido com n al instalar esta bomba No intente instalar esta bomba si est cansado o bajo el efecto de
27. ec Submersible Sarl Sump Pumps SSP 1000 OPERATOR S MANUAL e Pour fran ais voire page 9 e Para el castellano ver la pagin 17 WARNING Read this Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury aded from http www thepdfportal RIDGID FERRER EEE Table of Contents Recording Form for Pump Serial 1 General Safety Information Work Area tcc tage eee ee cho ap Deda ci dates EE 2 Electrical Safety pin a AG bee athe fan eet es Cle dt ete 2 Personal Safety 2 iii A bee ded poke 3 Specific Safety Information Submersible Pump Safety 3 Description and Specifications DeSCNPUON Poe oe Dade ae a Raa dee ad Pe See ee 3 SPeCifiCALIONS ns ir Gh anaes os des heeds aid ds ae Ea rata A 4 Performance Curve and Performance Chart 2 4 Pump Installation Installation ede as a eek Shah it eh thd oh oe pee hee Se eS 4 5 6 Maintenance Instructions
28. er la pompe ou pour retirer la fiche de la prise Gardez le cordon loin de la chaleur de l huile bords tranchants ou pi ces mobiles Remplacez imm diatement les cordons endommag s car ils augmentent le risque de choc lectrique La pompe doit tre branch e dans une prise qui inclut un disjoncteur diff rentiel DD Dans le cas de fuite de courant un DD se d clenchera r duisant ainsi le risque de blessure grave ou de mort suite un choc lectrique Prise mise Broche de terre masse y TEST RESET H Cordon Figure 1 Avant d utiliser testez le disjoncteur diff rentiel DD pour vous assurer qu il fonctionne correctement Un DD r duit le risque de choc lectrique _ N utilisez pas de rallonge car cela augmente le risque de choc lectrique Si n cessaire installez une prise la terre plus pr s de la pompe S curit personnelle AVERTISSEMENT e Restez vigilant regardez ce que vous faites et utilisez du sens commun en installant cette pompe N essayez pas de l installer fatigu ou sous l influence de drogues d alcool ou de m dicaments Un moment d inattention peut provoquer de graves blessures Habillez vous correctement Ne portez pas de v tements amples ni de bijoux Attachez les cheveux longs Gardez les cheveux v tements et gants loin des pi ces mobiles car ils peuvent se prendre dans les pi ces mobiles Ne v
29. es instructions Le non respect de toutes les instructions ci apr s pourrait mener un choc lectrique mortel un incendie des dommages la propri t et ou de graves blessures CONSERVER CES INSTRUCTIONS Aire de travail ADANGER Ne faites pas fonctionner la pompe dans des atmosph res explosives telles qu en pr sence de liquides gaz ou poussi re inflammables Les moteurs de pompe cr ent des tincelles qui pourraient enflammer la poussi re ou les fum es Gardez les spectateurs les enfants et les visiteurs loin en installant la pompe Des distractions peuvent mener a des erreurs S curit lectrique il AVERTISSEMENT Cette pompe doit tre branch e dans une prise install e correctement et mise terre conform ment tous les codes et ordonnances applicables Ne retirez jamais la broche de masse et ne modifiez pas la fiche N utilisez pas de fiches d adaptateur V rifiez aupr s d un lectricien qualifi si vous n tes pas certain que la prise soit mise la terre Si la pompe une d faillance lectrique ou cesse de fonctionner la masse offre une voie de faible r sistance pour loigner l lectricit de l usager Le c blage lectrique doit tre effectu par un lectricien qualifi Tout mauvais c blage peut mener un choc lectrique mortel e N abusez pas du cordon Ne Putilisez jamais pour transport
30. esiones y la anulaci n de la garant a Al reparar una bomba use s lo piezas id nticas de repuesto Siga las instrucciones en la Secci n de mantenimiento de este manual Si no usa las piezas autorizadas o no sigue las instrucciones de mantenimiento puede crear riesgos de severas descargas el ctricas o lesiones NOTA La garant a quedar anulada si desarma el motor Informaci n espec fica de seguridad AADVERTENCIA Riesgo de descargas el ctricas Esta bomba trae un enchufe con puesta a tierra Para reducir el riesgo de descargas el ctricas aseg rese de conectarlo a una toma de corriente con puesta correcta a tierra que est protegida por un interruptor Por su propia seguridad antes de armar y operar esta unidad lea cuidadosamente todo el Manual del Operador Aprenda c mo funciona se aplica esta unidad asi como sus riesgos peculiares Si tiene alguna pregunta comun quese con el Departamento de Servicios T cnicos de Ridge Tool Company llamando al 800 519 3456 Aspectos de seguridad de la bomba sumergible APELIGRO No use la bomba para bombear l quidos inflamables o explosivos como gasolina petr leo combustible fueloil queroseno solventes diluyentes etc No la use en una atm sfera inflamable o explosiva Esta bomba s lo debe usarse para bombear agua limpia El uso inadecuado puede causar graves lesiones y o la muerte AADVERTENCIA Si hay agu
31. il soit de la bonne taille Figure 2 L installation de la pompe submersible 2 Assurez vous que la prise lectrique soit a la terre de calibre de 115 volts d au moins 15A et prot g e par un disjoncteur diff rentiel DD AAVERTISSEMENT L utilisation d une prise mise la terre prot g e par un DD r duit le risque de choc lectrique mortel 3 Inspectez le cordon d alimentation et la prise pour tout signe de dommage Si la prise n a pas de broche de masse ou si le cordon est endommag n installez pas la pompe avant de remplacer le cordon Ridge Tool Company 13 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EEE EE EE mss i Interrupteur a diaphragme SP 330D seulement 4 Retirez les deux attaches dans la volute de fonte pr s de la zone de d charge Alignez le trou avec l interrupteur a diaphragme et replacez les attaches sans trop resserrer Figure 3 Fixer l interrupteur avec les deux 2 vis fournies Figure 3 Interrupteur diaphragme AVERTISSEMENT Ne coupez jamais la broche de masse et n utilisez pas d adaptateur A AVERTISSEMENT Supportez la pompe et la tuyauterie en assemblant et apr s l installation sinon les tuyaux peuvent casser ou la pompe ne pas fonctionner menant des dommages la propri t et ou des blessures personnelles SSP 1000 D tecteur d eau tat s
32. ise el cord n y el enchufe para detectar cualquier da o Si el enchufe no tiene la espiga de puesta a tierra o el cord n est da ado no instale la bomba hasta que haya recambiado el cord n Conmutador de diafragma modelo SP 330D solamente 4 Quite los dos sujetadores del caracol de hierro fundido cerca del rea de descarga Ponga en l nea el orificio con el interruptor de diafragma y vuelva a colocar los sujetadores sin apretar demasiado Figura 3 Fije el interruptor con los 2 dos tornillos incluidos AA 7 gt Figura 3 Conmutador de diafragma AADVERTENCIA Nunca corte una espiga de puesta a tierra ni use un adaptador AADVERTENCIA soporte la bomba y la tuber a al armar e instalar la bomba Si no le da este soporte la tuber a puede romperse o la bomba puede caerse causando da os materiales y o lesiones personales SSP 1000 S lo sensor de agua de estado s lido 5 Enchufe el cord n de alimentaci n de la bomba directamente en la parte de atr s del enchufe del cord n del sensor de agua de estado s lido Figura 4 6 Coloque la bomba en el sumidero Coloque la bomba en una superficie fuerte y plana AVISO No use la bomba directamente sobre arcilla grava o en ninguna superficie de material suelto o arenoso Estas superficies contienen piedrecitas arena que pueden obstruir o da ar la bomba Esto podr a ocasionar da os a la bomba y da os materi
33. isjoncteur 2 Faible tension de ligne 2 Si la tension est sous 108 volts v rifiez la taille des fils 3 Moteur us 3 Remplacez le moteur ou la pompe 4 Interrupteur us 4 Remplacez l interrupteur 5 Rotor ne tourne pas 5 Si le rotor ne tourne pas retirez le bo tier et retirez le 6 Obstruction de flotteur blocage 6 Assurez vous que le flotteur se d place librement vers le haut et le bas Pompe d marre et s arr te trop 1 Retour d eau du tuyau 1 Installez ou remplacez le clapet souvent 2 Interrupteur d fectueux 2 Remplacez l interrupteur Pompe ne s teint pas ou le 1 D tecteur d eau tat solide 1 Nettoyer la surface de d tecteur voir les tapes protecteur thermique s arr te sale mod le SSP 1000 d entretien uniquement 2 Interrupteur d fectueux 2 Remplacez l interrupteur 3 Obstacle dans le tuyau 8 Retirez la pompe et nettoyez le pompe et les tuyaux 4 Flotteur obstru 4 Assurez vous que le flotteur se d place librement vers le haut et le bas Pompe fonctionne mais livre peu 1 Faible tension de ligne 1 Sila tension est sous 108 volts v rifiez la taille des fils ou aucune eau 2 Rotor bloqu 2 Nettoyez le rotor 4 Figure Description No cat RIDGID No cat RIDGID No cat RIDGID No cat RIDGID SP330 SP330D SP500 SSP 1000 1 Trousse de flotteur 88557 N A 88557 N A 2 Ass d interrupteur haut 88562 N A 88562 25138 2a Ass du haut membrane N A 88567
34. l a o y limpie el sumidero seg n sea necesario 3 Compruebe el buen funcionamiento de la bomba cada mes llenando el sumidero con agua hasta que la bomba se active 4 Revise cada mes todas las conexiones de tuber as para detectar cualquier fuga o pieza aflojada SSP 1000 S lo sensor de agua de estado s lido 5 Es posible controlar que la bomba funcione correctamente quitando brevemente el cord n de alimentaci n de la bomba de la parte de atr s del enchufe del sensor de agua de estado s lido y enchuf ndolo directamente el tomacorriente conectado a tierra Bajo estas condiciones la bomba trabaja en forma continua Una vez comprobado el funcionamiento de la bomba vuelva a enchufar el cord n de alimentaci n de la bomba en la parte de atr s del enchufe del cord n del sensor de agua de estado s lido ver Figura 4 NOTA Desarmar el motor puede causar la anulaci n de la garant a Programa recomendado de recambio de piezas Reemplace el interruptor de la bomba cada 2 a os Use el n mero de Cat RIDGID que se indica en la p gina 24 Reemplace el flotante cada 2 a os Use el n mero de Cat RIDGID que se indica en la p gina 24 La bomba SSP 1000 usa un control electr nico de estado s lido sin partes en movimiento ver Figura 4 as que no se requieren repuestos Servicio y reparaci n AADVERTENCIA y reparaci n en esta bomba deben ser
35. ll del fondo de la cuenca AVISO El tubo exterior debe estar inclinado hacia abajo para drenar Esto ayuda a prevenir que los desechos entren en el tubo de descarga y asimismo evita que el agua retenida se congele lo que puede da ar la bomba 3 Instale la cubierta de la cuenca del sumidero que no se incluye con la bomba para prevenir que los desechos obstruyan o da en la bomba Instrucciones de mantenimiento ADVERTENCIA Desconecte siempre el suministro el ctrico o desenchufe la bomba antes de intentar instalar reparar reubicar o realizar cualquier tarea de mantenimiento Si la fuente de alimentaci n el ctrica no est visible bloquee y etiquete la posici n abierta en posici n OFF de apagado para prevenir la aplicaci n inesperada del suministro el ctrico De no hacerlo as usted puede sufrir una descarga el ctrica fatal S lo un electricista calificado debe intentar reparar esta unidad La reparaci n inadecuada puede ocasionar descargas el ctricas fatales El motor est lleno de aceite y est sellado herm ticamente para funcionar menor temperatura Espere 2 horas para que el motor se enfr e antes de repararlo El aceite caliente est bajo presi n y puede acarrear graves quemaduras 1 Compruebe el funcionamiento del Interruptor de circuito de tierra accidental GFCI cada mes 2 Mantenga limpio y libre de todo objeto extra o el punto de entrada de la bomba Rev selo una vez a
36. not rotating 5 If impeller will not turn remove housing and remove blockage 6 Float obstruction 6 Make sure float moves freely up and down Pumps start and stops too 1 Backflow of water from 1 Install or replace check valve often piping 2 Defective switch 2 Replace switch Pump will not shut off or 1 Dirty Solid State Water 1 Clean sensor face see Maintenance steps thermal protector turns off Sensor Model SSP 1000 only 2 Defective switch 2 Replace switch 3 Obstacle in piping 3 Remove pump and clean pump and piping 4 Float obstructed 4 Make sure float moves freely up and down Pump operates but delivers 1 Low line voltage 1 If voltage is under 108 volts check wiring size little or no water 2 Plugged impeller 2 Clean out impeller Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID SP 330 SP 330D SP 500 SSP 1000 Submersible Sump Pumps Figure Description RIDGID cat RIDGID cat RIDGID cat RIDGID cat SP330 SP330D SP500 SSP 1000 1 Float Kit 88557 N A 88557 N A 2 Switch Top Assembly 88562 N A 88562 25138 2a Top Assembly diaphragm N A 88567 N A N A 2b Solid State Water Sensor N A N A N A 25143 3 Stator 88577 88577 88582 25148 4 Lower Bracket Rotor 88587 88587 88592 25153 5 Cast Iron Impeller 88597 88597 88597 25158 6 Cast Iron Volute 88602 90382 88602 88602 8 Ridge Tool C
37. o se detenga Esto podr a causar una inundaci n o da os materiales IMPORTANTE Aseg rese de que haya un espacio suficiente para que el interruptor flotante se mueva libremente durante la operaci n Se requiere un espacio libre de 1 pulgada como m nimo 9 Conecte un tubo r gido de 1 1 4 pulgadas de di metro al manguito de goma en la v lvula de retenci n que no se incluye con la bomba Voltee el manguito hacia el tubo de 1 1 2 pulg de di metro Apriete las abrazaderas 10 Inserte el enchufe del cord n de suministro el ctrico de la bomba directamente en la toma el ctrica de puesta a tierra de 115 voltios que est protegida mediante un interruptor de circuito de tierra accidental Figura 1 22 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441_347927 paf RIDGID 5 330 5 3300 500 55 1000 AADVERTENCIA cuando vaya a tender el cord n de alimentaci n el ctrica prot jalo contra objetos cortantes superficies calientes aceites y agentes qu micos Evite los quiebres no ponga abrazaderas apretadas en el cord n reemplace de inmediato todo cord n da ado Pruebas 1 Llene la cuenca del sumidero con agua 2 Mientras la bomba est drenando la cuenca verifique que el tubo de descarga est llevando el agua hasta un punto situado por lo menos a 4 5 m m s a
38. olide uniquement 5 Introduire la fiche du cordon d alimentation de la pompe directement dans le dos de la prise du cordon du d tecteur d eau tat solide Voir Fig 4 La surface de travail du senseur doit tre libre de mat riaux trangers Figure 4 D tecteur d eau tat solide 6 Placer la pompe dans le puisard Placer la pompe sur une surface solide et niveau AVIS Ne placez pas directement sur l argile le gravier ou toutes surfaces laches ou sablonneuses car elles contiennent de petites roches ou du sable qui pourraient bloquer ou endommager la pompe provoquant une d faillance et donc une inondation et des dommages la propri t 7 La pompe a une d charge de 1 1 2 po 3 8 cm S il a un tuyau de 1 1 4 po 3 17 cm NPT vous pouvez utiliser un raccordement d adaptateur non fourni N utilisez pas de tuyau de moins de 1 1 4 po 3 17 cm NPT car les tuyaux trop petits auront une sortie r duite 8 Il faut un clapet dans la ligne de d charge pour viter tout retour l arr t de la pompe Il est pr f rable d installer directement le clapet la d charge Enfilez le sur la d charge de pompe AVIS Attention de ne pas d nuder ou fausser le filetage N utilisez pas de mastic de jointement AVIS Le flexible de d charge doit tre utilis seulement temporairement 1 faut un tuyau de m tal ou de PVC rigide pour une installation permanente Si vous utilisez
39. omatiquement quand la pr sence d eau est d tect e AVIS Cette pompe n est pas con ue pour traiter l eau sal e la saumure les refoulements de lavage ou toute autre application pouvant contenir des produits chi miques caustiques et ou des mati res trang res Cette pompe ne convient pas pour la vie aquatique La pompe peut tre endommag e ou manquer si utilis e pour ces applications et cela annulera la garantie AVI 5 ll est fortement recommand d utiliser un syst me de secours de batterie Les pannes de courant le d bit d eau excessif le d clenchement de DD et l usure de la pompe primaire peuvent provoquer des inondations Un syst me de secours r duit ce risque Contactez votre distributeur Ridge Tool 12 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EEE EE Sp cifications Moteur prier s 1 3 HP et 1 2 HP Enroulement a courtterme 1 HP courant a enroulement auxiliaire Calibre Monophase 120V 1 3 HP 9 5 A 1 2 HP 10 A 1HP 9 8 Pompe WS HP sis eda eee su 3100 gal h W2 AP 4400 gal h rss 5400 gal h Plage de temp rature liquide 40F 120F Coupure de niveau d encl 9 po 7 po SSP 1000 Coupure de niveau de d cl 4 po po SSP 1000 SP 300 SP 300D SP 500 20 SP 500A E ssp
40. ompany Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID Pompes de puisard submersibles SP 330 SP 330D SP 500 et SSP 1000 Pompes de puisard submersibles SP 330 SP 330D SP 500 et SSP 1000 Enregistrez le num ro de s rie de la d calcomanie du produit ci apr s No de s rie 351405 005 8 06 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EEE EE EEE ET Table des mati res Formulaire d enregistrement du num ro de s rie de la pompe 9 Informations g n rales de s curit Aire de travail 2 aan die ee aoe Le d tente PR antenne 11 S curit lectriqu suis ra a SE pee donne RES lea aes 11 S curit personnelle visa SIN cis bade eG hak kee banda EIN ka hae a ew hides bade 11 SONICO 12 Information de s curit sp cifique S curit de pompe submersible 12 Description et sp cifications DESCAPION 2242228 a baa Pe eee haa DRE eee e Pt ne 12 Specifications Wa eae 13 Courbe et tableau de performance 13 Installation de la pompe Installation 8 NENNT N NN eG H
41. ous penchez pas trop Posez bien les pieds et assurez vous de ne jamais perdre l quilibre car cela vous permet de mieux contr ler les situations inattendues Utilisez de l quipement de s curit Portez toujours une protection oculaire Utilisez des masques antipoussi res des souliers de s curit antid rapants et un casque protecteur selon le cas Ridge Tool Company 11 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EEE EEE ETES ET Service AVERTISSEMENT Le moteur est rempli d huile et scell pour r duire P chauffement Attendez 2 heures pour que le moteur refroidisse avant tout entretien L huile chaude est sous pression et pourrait br ler gravement Lentretien de la pompe doit tre effectu seulement par un personnel d entretien qualifi L entretien et la r paration par une personne non qualifi e pourraient provoquer des blessures et annuler la garantie faisant le service de la pompe utilisez seulement des pi ces de rechange identiques Suivez les instructions sous la section d entretien de manuel Utilisez des pi ces non autoris es ou le non respect des instructions d entretien peut causer un risque de choc lectrique ou de blessure NOTE D monter le moteur annulera la garantie Information de s curit sp cifique AAVERTISSEMENT Risque de choc lectrique Cette pompe est aliment e par une
42. pi 4 57 m de la fondation AVI 5 La tuyauterie ext rieure doit tre pench e vers le bas pour drainer ce qui aide a emp cher les d bris d entrer dans le tuyau de d charge et aussi l eau emprisonn e de geler ce qui pourrait endommager la pompe 3 Installez le couvercle de fosse de puisard non fourni pour viter que les d bris bloquent ou endommagent la pompe Instructions d entretien AAVERTISSEMENT e Coupez toujours le courant ou d branchez la pompe avant d essayer d installer r parer replacer ou entretenir l appareil Si la source de courant est hors de vue verrouillez et tiquetez en position ouverte OFF pour viter toute application impr vue de courant Sinon cela pourrait mener un choc lectrique mortel Seul un technicien qualifi devrait r parer cet appareil Toute mauvaise r paration peut mener un choc lectrique mortel Le moteur est rempli d huile et scell pour r duire l chauffement Attendez 2 heures pour que le moteur refroidisse avant tout entretien L huile chaude est sous pression et pourrait br ler gravement 1 V rifiez l op ration du disjoncteur diff rentiel DD chaque mois 2 Gardez l entr e de la pompe propre et sans objets trangers Inspectez au moins une fois et nettoyez le puisard au besoin 3 V rifiez la pompe pour vous assurer de son bon fonctionnement chaque mois en remplissant le puisard d eau jusq
43. prise mise la terre Pour r duire les risques de choc lectrique assurez vous qu elle soit branch e seulement a une prise mise a la terre correctement prot g e par un DD Pour votre propre s curit avant d assembler et de faire fonctionner l appareil lisez attentivement et en entier ce manuel des op rations Apprenez l application d op ration et les dangers possibles de cet appareil ci Appelez les sevices techniques de Ridge Tool Company au 800 519 3456 si vous avez des questions S curit de la pompe submersible ADANGER e N utilisez pas pour pomper des fluides inflammables ou explosifs tels qu essence fuel k ros ne solvants diluants etc N utilisez pas dans une atmosph re inflammable et ou explosive La pompe doit seulement servir pour pomper de l eau claire Une mauvaise utilisation peut mener des blessures personnelles et ou la mort AVERTISSEMENT e S il y a de l eau ou de l humidit sur le sol ou sur le plancher pr s de la pompe ne marchez pas dessus avant de couper le courant Si la bo te d arr t est dans le sous sol appelez un lectricien Le non respect de cet avertissement pourrait mener un choc lectrique mortel Coupez toujours la source de courant avant d essayer d installer de r parer de replacer ou de faire l entretien de la pompe Ne manipulez jamais une pompe ou son moteur avec les mains mouill es ou debout sur un
44. sar inundaciones Un sistema de pila de reserva reduce este riesgo Consulte a su distribuidor de Ridge Tool Company Especificaciones Motor EE 1 3 HP y 1 2 HP Polo protegido 1 HP Fase dividida Capacidad nominal 120V monof sica 1 3 HP 9 5 Amps 1 2 HP 10 Amps 1 HP 9 8 Amps 3100 GPH a cero pies 4400 a cero pies 5400 GPH a cero pies Gama de temperaturas de los l quidos 40F a 120F Nivel de activaci n 9 0 23 Nivel de activaci n 7 0 18 SSP 1000 Nivel de desactivaci n 4 0 10 Nivel de desactivaci n 3 0 08 m SSP 1000 Curva de rendimiento 25 SP 300 a 20 SP 500A LI ssp 1000 15 gt S 10 5 0 1000 2000 3000 4000 5000 6000 Litros por hora Tabla de rendimiento Cabeza de Modelo descarga Om 1 5m 3 1m 4 6m SP 330 Litros hora 11734 11355 10220 6359 SP 330D Litros hora 11734 11355 10220 6359 SP 500 Litros hora 16654 15519 12112 7570 SSP 1000 Litres hora 20439 18395 15897 12718 Instalaci n de la bomba We Esta bomba s lo debe usarse para bombear agua limpia No use esta bomba para bombear l quidos como gasolina petr leo combustible fueloil o queroseno No la use en atm sferas inflamables explosivas El uso incorrecto podr a ocasionar lesiones personales y o la muerte AADVERTENCIA Para prevenir da os ma
45. seguridad alguien puede lesionarse AVISO indica informaci n importante que si no se sigue puede causar da os al equipo o inundaciones AADVERTENCIA Lea y comprenda todas las instrucciones Pueden ocurrir descargas el ctricas incendios da os materiales y o graves lesiones personales si no se siguen todas las instrucciones indicadas a continuaci n CONSERVE ESTAS INSTRUCCIONES rea de trabajo APELIGRO No opere la bomba en atm sferas explosivas como por ejemplo en presencia de l quidos gases o polvos inflamables Los motores de la bomba generan chispas que pueden incendiar el polvo o los gases Mantenga a los transe ntes ni os y visitantes lejos del sitio de instalaci n cuando vaya a instalar la bomba Las distracciones pueden ocasionar errores Seguridad el ctrica ill A ADVERTENCIA We Esta bomba debe conectarse a una toma de corriente correctamente instalada y ponerse a tierra en conformidad con todas las ordenanzas y c digos aplicables Nunca elimine la espiga de puesta a tierra ni modifique el enchufe de ninguna manera No use enchufes adaptadores Consulte a un electricista calificado si no est seguro de que la toma est puesta a tierra Si la bomba sufre un desperfecto el ctrico o se aver a la puesta a tierra proporciona una ruta de baja resistencia para llevar la electricidad lejos del usuario La distribuci n del cabl
46. soit pas applicable Cette garantie vous donne des droits sp cifiques qui peuvent tre ventuellement compl t s par d autres droits pr vus par votre l gislation locale Il n existe aucune autre garantie expresse Cette GARANTIE PERPETUELLE INTEGRALE est la seule et unique garantie couvrant les produits RIDGID Aucun employ agent distributeur ou tiers n est autoris modifier cette garantie ou offrir une garantie suppl mentaire au nom de la RIDGE TOOL COMPANY FULL LIFETIME WARRANTY Qu cubre Las herramientas RIDGID est n garantizadas contra defectos de la mano de obra y de los materiales empleados en su fabricaci n Duraci n de la cobertura Esta garant a cubre a la herramienta RIDGID durante toda su vida til La cobertura de la garant a caduca cuando el producto se torna inservible por razones distintas a las de defectos en la mano de obra o en los materiales C mo obtener servicio Para obtener los beneficios de esta garant a env e mediante porte pagado la totalidad del producto a RIDGE TOOL COMPANY en Elyria Ohio o a cualquier Servicentro Independiente RIDGID Las llaves para tubos y dem s herramientas de mano deben devolverse a la tienda donde se adquirieron Lo que hacemos para corregir el problema El producto bajo garant a ser reparado o reemplazado por otro a discreci n de RIDGE TOOL y devuelto sin costo o si a n resulta defectuoso despu s de haber sido repar
47. sont garanties contre d fauts de mat riau et main d oeuvre En r parant cette pompe seules des pi ces de rechange identiques doivent tre utilis es sinon cela pourrait cr er un risque d inondation de dommages la propri t de choc lectrique mortel ou d autres blessures graves et annuler votre garantie Si vous avez des questions au sujet du service ou des r parations de cet appareil appelez ou crivez Ridge Tool Company Technical Service Department 400 Clark Street Elyria Ohio 44036 2023 T l 800 519 3456 Courriel TechService ridgid com Pour le nom et l adresse de votre centre de service autoris ind pendant le plus pr s contactez la Ridge Tool Company au 800 519 3456 ou http www ridgid com Pour l Assistance au Client appeler le 1 877 9RIDGID Ridge Tool Company 15 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EEE EE EE ETES AT D pannage AVERTISSEMENT Laissez refroidir la pompe pendant au moins deux heures avant toute r paration car la pompe contient de l huile sous pression D branchez la pompe de la source de courant avant tout entretien TABLEAU DE D PANNAGE Sympt me Cause s possible s Mesure corrective Pompe ne d marre pas ou ne 1 Fusible ou disjoncteur grill 1 Si grill remplacez avec la bonne taille de fusible tourne pas ou r initialiser le d
48. temporairement un flexible assurez vous que la pompe est bien install e dans la fosse du puisard pour viter tout d placement sinon cela pourrait cr er une interf rence d interrupteur et emp cher la pompe de d marrer ou d arr ter ce qui pourrait mener des inondations et des dommages la propri t IMPORTANT Assurez vous qu il y ait suffisamment d espace pour que l interrupteur flotteur se d place librement durant l op ration faut au moins 1 2 54 cm 9 Raccordez le tuyau rigide de 1 1 4 po 3 17 cm de diam tre au manchon de caoutchouc du clapet non fourni Inversez le manchon pour les tuyaux de 1 1 2 po 3 8 cm de diam tre Resserrez les pinces 10 Ins rez la prise du cordon de la pompe directement dans une prise la terre de 115 volts prot g e par un disjoncteur diff rentiel DD Figure 1 A AVERTISSEMENT En acheminant le cordon prot gez le des objets tranchants surfaces chaudes huiles et produits chi miques viter les coques du cordon ne pas appliquer au cordon de colliers de serrage resserr s remplacer en suite tout cordon endommag 14 Ridge Tool Company Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID EEE EE EE TE AT Testing 1 Remplissez la fosse du puisard d eau 2 Tandis que la pompe vide la fosse v rifiez que le tuyau de d charge transporte l eau un point au moins 15
49. teriales graves lesiones o muerte se requiere la instalaci n correcta de la bomba Por tanto deben seguirse estos procedimientos La bomba debe conectarse a una toma con puesta tierra que incluya un interruptor de circuito de tierra accidental GFCI Figura 1 Desconecte siempre la fuente de alimentaci n el ctrica antes de intentar instalar reparar reubicar o dar mantenimiento a la bomba Nunca maneje la bomba o el motor de la bomba con manos h medas o si usted est de pie sobre una superficie mojada o h meda o en agua cuando la bomba est conectada al suministro el ctrico Instalaci n 1 Construya una cuenca de concreto acero o pl stico para el sumidero que tenga 24 pulgadas 61 cm de fondo y al menos 11 pulgadas 28 cm de di metro Figura 2 Si ya hay un sumidero aseg rese de que tenga el tama o correcto Figura 2 Instalaci n de bomba sumergible 2 Aseg rese de que la toma de corriente est puesta a tierra y tenga capacidad nominal para 115 voltios y al menos 15 amperios La toma debe estar protegida por un interruptor de circuito de tierra accidental GFCI AADVERTENCIA El uso de una toma con puesta a tierra protegida con un interruptor GFCI reduce el riesgo de descargas el ctricas fatales Ridge Tool Company 21 Pdf downloaded from http www thepdfportal net 3e9ba97e 13bf 4ad7 a708 afa8706eb441 347927 pdf RIDGID cocina EE TE TN 3 Rev
50. u ce que la pompe d marre 4 Inspectez toutes les connexions de plomberie pour toutes fuites ou desserrement chaque mois SSP 1000 D tecteur d eau tat solide uniquement 5 Pour v rifier le bon fonctionnement de la pompe retirer bri vement le cordon d alimentation de la pompe de l arri re de la prise du d tecteur d eau tat solide et le brancher directement dans la prise de courant mise la terre Dans cette condition la pompe travaille continuellement Une fois v rifi le bon fonctionnement de la pompe rebrancher le cordon d alimentation de la pompe dans le dos de la prise du d tecteur d eau tat solide voir Figure 4 NOTE D montez le moteur annulera la garantie Suggestions d horaire de remplacement des pi ces Remplacez l interrupteur de la pompe tous les 2 ans Voir la page 16 pour le no de cat Remplacez le flotteur aux 2 ans Voir la page 16 pour le No de cat Ridgid Le mod le SSP 1000 utilise un d tecteur lectronique tat solide qui n a pas de pi ces mobiles voir Figure 4 et pourtant il a pas besoin de pi ces de rechange Service et r paration AVERTISSEMENT Le travail de service et r paration de cette pompe doit tre effectu par un personnel qualifi La pompe doit tre apport e un centre de service autoris ind pendant RIDGID ou retourn e lusine Toutes les r parations effectu es dans des installations de service Ridge
51. w may result in fatal electric shock fire property damage and or serious personal injury SAVE THESE INSTRUCTIONS Work Area ADANGER Do not operate pump in explosive atmospheres such as in the presence of flammable liquids gases or dust Pump motors create sparks which may ignite the dust or fumes Keep by standers children and visitors away while installing pump Distractions can result in mistakes Electrical Safety W AWARNING This pump must be plugged into an outlet properly installed and grounded in accordance with all applicable codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use any adapter plugs Check with a qualified electrician if you are not sure the outlet is grounded If the pump should electrically malfunction or break down grounding provides a low resistance path to carry electricity away from the user Electrical wiring must be performed by a quali fied electrician Improper wiring could result in fatal electrical shock Do not abuse cord Never use the cord to carry the pump or pull the plug from an outlet Keep cord away from heat oil sharp edges or mov ing parts Replace damaged cords immediate ly Damaged cords increase the risk of electrical shock Pump must be plugged into an outlet recepta cle that includes a Ground Fault Circuit Interrupter GFCI In the event of current leak age a GFCI will trip thus re
52. ype power cord The motor has an automatic reset thermal protector to prevent burnouts due to overloading or clogging The pump is designed to automatically maintain water level between factory preset points The SSP 1000 is provided with a solid state electronic water level control When water is detected the pump will start automatically NOTICE This pump is not designed to handle salt water brine laundry discharge or any other appli cation which may contain caustic chemicals and or for eign materials This pump is not suitable for use with aquatic life Pump damage or failure could occur if used in these applications and will void the warranty NOTICE It is strongly recommended that a battery back up system be used Power outages excessive water flow G F C I tripping and primary pump wear can cause flooding A battery back up sys tem reduces this risk Contact your Ridge Tool distrib utor RIDGID FERME ETS Specifications Motor 1 3 amp 1 2 Shaded Pole 1HP Split Phase Rating EE 120V Single Phase 1 3 HP 9 5 Amps 1 2 HP 10 Amps 1HP 9 8 Amps Pump WO GE 3100 GPH 0 Ft 1 2 HP 4400 GPH 0 Ft e E 5400 GPH 0 Ft Liquid temperature range 40F to 120 Cut in 9 7 SSP 1000 Cut out level 4 3 SSP 1000 Performance Curve 25 Discharge Feet 0 1000 2000
Download Pdf Manuals
Related Search
Related Contents
Procedimiento para la Medición del Potencial de Hidrógeno 備 エントランスライト 取扱説明書 4. Understanding Groundwater & Wells in Manual Drilling Loi 95-014 1995-07-13 PR Chapitre I : Dispositions générales Manual de instalación y mantenimiento Electroválvulas de 4 y 5 vias Franklin S - J Series User's Manual Copyright © All rights reserved.