Home
Installation Guide Guía de instalación
Contents
1. main body 3 Insert and tighten the 2 security screws into the side of the main body as illustrated Recommended torque of 0 5 0 7NM 4 Turn power on 5 Test unit for correct operation Do not use sealant when fixing the unit to the wall Do not paint coat the main body or place graphical stickers on it or this may damage the anti microbial surface Desembalaje Coloque en la posici n deseada 15 16 pulgadas 38 40 cm a la parte superior de Placa posterior Cuerpo principal Sea cuidadoso al retirar la carcasa Es posible que la carcasa tenga bordes o esquinas filosas que pueden provocar cortes u otros da os 1 Coloque el cuerpo principal en un lienzo para evitar marcar la superficie 2 Quite los tornillos de seguridad del cuerpo principal con la herramienta de servicio incluida Gu rdelos en un lugar seguro 3 Levante la placa posterior del cuerpo principal 4 Si la entrada del cableado el ctrico se realizar desde la parte posterior quite la arandela de goma del orificio de entrada posterior del cableado el ctrico Guarde en un lugar seguro Entrada Entrada lateral del lateral del cableado cableado el ctrico el ctrico a Entrada posterior del cableado el ctrico PRECAUCI N Antes de la instalaci n decida si la entrada del cableado el ctrico se realizar desde la parte 3 1 posterior o 3 2 late
2. O UTILIZAR ESTA UNIDAD LEA TODAS LAS INSTRUCCIONES E INDICACIONES DE PRECAUCION DE ESTE MANUAL Y DE LA GUIA DE INSTALACION GUARDE ESTAS INSTRUCCIONES A ADVERTENCIA El trabajo de instalaci n y conexi n el ctrica debe realizarlo un electricista calificado conforme las leyes locales estatales y federales y los est ndares y c digos aplicables incluso las regulaciones relacionadas con la construcci n ign fuga A ADVERTENCIA Riesgo de choque el ctrico Si la carcasa se quita o se maneja incorrectamente las piezas internas de la unidad pueden causar da os o deteriorarse de manera permanente A ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS DESCARGAS EL CTRICAS O LESIONES PERSONALES OBSERVE LO SIGUIENTE ANTES DE LA INSTALACI N Antes de comenzar la instalaci n debe confirmar lo siguiente CABLEADO Compruebe que la alimentaci n el ctrica corresponda a la que aparece en la placa de especificaciones Si la unidad se conecta a un suministro el ctrico que no sea el indicado en la placa de especificaciones de esta la unidad puede sufrir da os permanentes o funcionar de manera inadecuada o insegura Debe incorporarse un sistema de desconexi n de todos los polos al cableado fijo conforme las normas locales y nacionales de cableado e La unidad debe contar con una conexi n a tierra apropiada Al conectar la unidad a la alimentaci n el ctrica conecte el cableado el ctrico conforme las leyes los c digo
3. solid state speed control device DO NOT USE ANY POWER WASH EQUIPMENT FOR CLEANING ON OR NEAR THIS UNIT AWARNING To avoid damage to the fascia surface during installation store the fascia in the original packaging until it is needed LOCATION e The unit is designed for dry internal locations only e Consult local and national accessibility codes and regulations for relevant installation guidelines Conformity and compliance is the responsibility of the installer e Ensure the required electrical supply is available for later connection e Ifthe unit is to be installed in a location subject to ADA regulations the installer should verify with their local governing entity to ensure that the unit is installed to ADA guidelines e This product is not suitable for mounting onto porous wall surfaces e g drywall without a splashback to avoid discoloring or damage to unprotected walls The recommended back panel for this product is available from Dyson AWARNING This unit contains substances known to the state of California to cause cancer birth defects and other reproductive harm Wash hand after installation or repair of this unit IMPORTANT Please refer to the Owner s Manual for details of the limited warranty Dyson will not be held liable for any damage to property or personal injury as a failure to comply with the instructions contained herein INSTRUCCIONES IMPORTANTES DE SEGURIDAD ANTES DE INSTALAR
4. Free 5 year warranty Register your warranty at www dysonairblade com AB Installation Guide Gu a de instalaci n dyson IMPORTANT SAFETY INSTRUCTIONS BEFORE INSTALLING OR USING THIS UNIT READ ALL INSTRUCTIONS AND CUSTOMARY MARKINGS IN THIS INSTALLATION GUIDE AND THE OWNER S MANUAL SAVE THESE INSTRUCTIONS AWARNING Installation work and electrical wiring must be done by qualified electrician s in accordance with all federal state and local laws and applicable codes and standards including fire rated construction AWARNING Risk of electric shock If casing is removed or handled improperly the internal components of the unit may cause harm or become permanently damaged AWARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING BEFORE INSTALLATION Before beginning any installation work you must confirm the following WIRING e Check that the electrical supply corresponds to that shown on the rating plate If the unit is connected to any electrical supply other than stated on the rating plate of the unit permanent damage or improper unsafe operation of the unit may result A means for all pole disconnection must be incorporated into fixed wiring in accordance with national and local wiring regulations e The unit must be grounded properly e When connecting the unit to the electricity supply use electrical wiring in accordance with all federal state and local laws and
5. ableado el ctrico desde el punto de entrada del cableado el ctrico hasta el bloque de terminales Si el cableado el ctrico se encuentra por encima de las paredes de gu a puede interferir con los componentes principales provocar que los tornillos de seguridad no se ajusten correctamente o que se fuerce la uni n del cuerpo principal con la placa posterior y se produzcan da os 2 Desatornille la abrazadera del cableado el ctrico de la placa posterior Quite el soporte del bloque de terminales del cableado el ctrico 3 Abra la lengiieta del soporte del bloque de terminales Ajuste el cable de l nea neutral y de conexi n a tierra en las ubicaciones del bloque de terminales correctas como se indica en el soporte del bloque de terminales 4 Antes de continuar compruebe que las conexiones se hayan realizado correctamente 5 Cierre la leng eta del soporte del bloque de terminales y col quelo dentro de la placa posterior 6 Atornille y ajuste la abrazadera del cableado el ctrico PRECAUCI N No ajuste de m s ya que puede aplastar el cableado el ctrico Ajuste del cuerpo principal PRECAUCI N No ajuste los tornillos de m s I Enganche el cuerpo principal de la unidad por encima del borde superior de la placa posterior Deslice el cuerpo principal de la unidad en la placa posterior En las instalaciones con entrada lateral de cableado el ctrico asegurese de que el se
6. applicable codes and standards including fire rated construction e If electrical wiring entry is to be from the side it must be secured using plastic or flexible metal conduit and suitable fittings that lock to the side bracket The conduit and fittings must be in accordance with local and national regulations Solid metal conduit is not suitable Ensure that the conduit and wires are long enough to connect to the backplate and the terminal block e When wiring in the back plate the maximum length for the wire s insulation to be stripped back is 0 25 e The unit requires a 15 amp circuit breaker with a dedicated line and neutral SAFETY e Isolate the power before installation or service INSTALLATION Make sure that the unit is installed in compliance with all building codes and or regulations The unit must be mounted on a flat vertical wall capable of supporting the full weight of the unit Use hardware as specified in this installation guide Ensure no pipe work gas water air or electrical cables wires or ductwork are located directly behind the drilling mounting area Dyson recommends the use of protective clothing eyeware and materials when installing repairing as necessary All metal parts in contact with this unit MUST be grounded including any wall covering Do not use sealant when fixing the unit to the wall To reduce the risk of fire or electric shock do not use this appliance with any
7. e DEBEN conectar a tierra todas las piezas met licas que entren en contacto con esta unidad incluidos los revestimientos de la pared No utilice sellador para fijar la unidad en la pared Para reducir el riesgo de incendio o descarga el ctrica no use este aparato con ning n dispositivo de control de velocidad de estado s lido NO UTILICE EQUIPOS DE LAVADO A CHORRO PARA LIMPIAR ESTA UNIDAD O LAS AREAS CERCANAS AADVERTENCIA Para evitar que la superficie de la tapa se da e durante la instalaci n guarde la tapa en su envoltorio original hasta que sea necesario sacarla UBICACI N La unidad est dise ada para colocarse en lugares interiores y secos nicamente Consulte los c digos y las normas de accesibilidad locales y nacionales para las pautas de instalaci n relevantes El cumplimiento de estas normas es responsabilidad del instalador Aseg rese de que est disponible el suministro de corriente el ctrica para conectarlo m s adelante Si la unidad se instalar en una ubicaci n conforme las normas de la ADA el instalador debe verificar con las autoridades del gobierno local para garantizar que la unidad se instale seg n las pautas de la ADA Este producto no es adecuado para su montaje en paredes de superficie porosa por ejemplo de yeso sin una protecci n contra salpicaduras para evitar la p rdida de color en la pintura o los da os en las paredes no protegidas Se encuentra disponible el panel trasero de Dyson recom
8. e la parte posterior el cableado el ctrico de la pared debe alinearse al punto de entrada del cableado el ctrico posterior de la placa posterior Utilice un l piz para marcar la ubicaci n sobre la pared Utilice la placa posterior para marcar la ubicaci n de los cuatro puntos de fijaci n Perfore Fije el panel trasero opcional si es necesario y 3 1 Entrada posterior del cableado el ctrico 0 25 pulgadas X Fy O Ubicaciones de los elementos de fijaci n primarios x4 No utilice tornillos avellanados Colocaci n de la placa posterior en la pared Fije la placa posterior firmemente a la pared con los elementos de montaje adecuados seg n el tipo de pared y el peso de la unidad No utilice tornillos avellanados No ajuste completamente hasta asegurar el cableado el ctrico Instalaci n del cableado el ctrico 1 Corte el orificio de entrada de la arandela de goma en el tama o correcto deje un orificio m s peque o que el di metro del cableado el ctrico para asegurarse de que el cableado el ctrico quede ajustado ES a Coloque el cableado el ctrico a trav s de la arandela Aseg rese de que el cableado el ctrico sea lo suficientemente largo para que se deslice correctamente por la placa posterior y hasta el bloque de terminales El cableado el ctrico debe queda
9. endado para este producto A ADVERTENCIA Esta unidad contiene sustancias reconocidas por el estado de California como causantes de c ncer anomal as cong nitas y otros da os reproductivos L vese las manos despu s de instalar o reparar esta unidad IMPORTANTE Consulte el Manual del propietario de para obtener informaci n sobre la garant a limitada Dyson no ser responsable de ning n da o a la propiedad o lesi n personal que se produzcan por no seguir las instrucciones especificadas en este documento Unpacking Main body Use caution when removing the casing The casing may have sharp edges corners which may cut or cause harm 1 Place the main body on a cloth to avoid marking its surface 2 Remove the security screws from the main body using the service tool provided Store safely 3 Lift the backplate out of the main body 4 If electrical wiring entry is to be from the rear remove the rubber grommet from the rear electrical wiring entry hole Store safely Positioning Side cable Side cable entry entry Rear cable entry CAUTION Before installation decide if the electrical wiring entry is to be from 3 1 the rear or 3 2 the side Follow the relevant instructions NOTE This product is not recommended for mounting onto porous wall surfaces e g drywall without a splashback to avoid discoloring or damage to
10. ing the backplate to the wall Fit the backplate securely to the wall using the appropriate hardware for the wall type and weight of the unit Do not use counter sunk screws Do not secure tightly until after the electrical wiring has been secured Installing the electrical wiring 1 Cut the entry hole in the rubber grommet to the correct size leave a hole smaller than the diameter of the electrical wiring to ensure the electrical wiring fits tightly a Pull the electrical wiring through the grommet Ensure the electrical wiring is long enough to route correctly through the backplate to the terminal block The electrical wiring must sit in the dedicated channel Fit the grommet into the backplate Ensure it is secure Secure the screws in the backplate Proceed with step 4 Connecting to terminal block 3 2 Side electrical wiring entry Left IMPORTANT Electrical wiring entry can be either from the 1 left or the right Decide which before you start The unit is designed to have only one side electrical wiring entry point Ensure you work only on the side of the fascia that you have chosen for the electrical wiring entry point 2 Use pliers to carefully nip out only one pre marked break out panel in the correct side of the main body Align to one of the edges and break off an initial part of the panel Align to the other edge and break off the second
11. llo del soporte lateral est ubicado correctamente contra el cuerpo principal Inserte y ajuste los 2 tornillos de seguridad en el lateral del cuerpo principal como se muestra en la ilustraci n Torsi n recomendada 0 5 a 0 7 NM Encienda la alimentaci n el ctrica 5 Pruebe la unidad para verificar si funciona correctamente No utilice sellador para fijar la unidad en la pared No pinte ni cubra el cuerpo principal tampoco coloque etiquetas adhesivas ya que pueden da ar la superficie antimicrobiana JN 55266 PN 60251 02 04 25 03 13 Dyson Customer Care Helpline L nea directa de Asistencia al cliente de Dyson www dysonairblade com dyson If you have any questions on the installation please call us toll free at 1 888 DYSON AB 1 888 397 6622 Si tiene alguna pregunta sobre la instalaci n ll menos a este n mero de acceso gratuito 1 888 DYSON AB 1 888 397 6622 NSF PROTOCOL P335 HYGIENIC COMMERCIAL HAND DRYERS The NSF logo is a registered trademark of NSF International Corporation
12. not use counter sunk screws Connecting to terminal block ZX WARNING Risk of electric shock Ensure power is not connected 1 Ensure the electrical wiring does not sit above the electrical wiring guide from the electrical wiring entry point to the terminal block If the electrical wiring sits above the guide walls it may interfere with main components prevent the security screws being fitted correctly or risk the main body being forced onto the backplate causing damage 2 Unscrew the electrical wiring clamp from the backplate Remove the electrical wiring terminal block holder 3 Open the flap on the terminal block holder Secure the line neutral and ground wires into the correct terminal block locations as indicated on the terminal block holder 4 Verify the connections are correct before proceeding 5 Close the flap on the terminal block holder and fit it into the backplate 6 Screw in and secure the electrical wiring clamp CAUTION Do not overtighten and crush the electrical wiring Attaching main body CAUTION Do not overtighten screws 1 Hook the main body of the unit over the top rim of the backplate 2 Swing the main body of the unit down onto the back plate For installations with the electrical wiring entry on the side ensure that the side bracket seal is correctly seated against the
13. omo gu a al realizar las perforaciones Aseg rese de que no haya ninguna tuber a de gas agua aire ni cables el ctricos alambres o conductos directamente detr s de la zona de montaje perforaci n 7 Empuje el cableado el ctrico por el soporte lateral y el sello del soporte lateral como se muestra Aseg rese de que el cableado el ctrico sea lo suficientemente largo para que se deslice correctamente por la placa posterior y hasta el bloque de terminales NOTA El largo del cableado el ctrico 0 25 pulgadas X Py O Ubicaciones de los elementos de fijaci n primarios x4 No utilice tornillos avellanados O Quinto orificio para entrada lateral ser diferente para las entradas del lado izquierdo y derecho 8 NOTA Aseg rese de usar el conector de conducto o collar n de cable apropiado no suministrado para la instalaci n Colocaci n de la placa posterior en la pared Fije la unidad principal firmemente a la pared con los elementos de montaje adecuados seg n el tipo de pared y el peso de la unidad Deslice el soporte lateral en el hueco entre la pared y la placa posterior Atornille a la pared y ajuste seg n corresponda No utilice tornillos avellanados Conexi n al bloque de terminales AX ADVERTENCIA Riesgo de choque el ctrico Aseg rese de que la alimentaci n el ctrica no est conectada 1 Aseg rese de que el cableado el ctrico no se encuentre por encima de la gu a del c
14. part of the panel Break off the whole part from the center After break off clean up the excess plastic Drill holes CAUTION Do not use the backplate as a NOTE If the side entry option is chosen a fifth hole will need to be drilled in the wall Make sure you work on the correct side for SA the installation The break out on the main body must match up with the bracket on the backplate Once the break out panel on the main body has been removed there is no option to swap sides looms Right guide when drilling Ensure no pipe work gas water air or electrical cables wires or ductwork are located directly behind the drilling mounting area 7 Pull the electrical wiring through the side bracket and side bracket seal as shown Ensure that electrical wiring is long enough to route correctly through the backplate to the terminal block NOTE Electrical wiring length will be different for left and right side entries 0 255 X Py O Primary fixing locations x4 Do not use countersunk screws O 5th hole for side entry 8 NOTE Ensure suitable cable gland conduit connector is used not provided for the installation Fixing the backplate to the wall Fit the main unit securely to the wall using the appropriate hardware for the wall type and weight of the unit Slide the side bracket into the recess between the wall and the backplate Screw to the wall and secure with the appropriate fitting Do
15. r posicionado en el canal dise ado para tal fin Sujete la arandela a la placa posterior Aseg rese de que est bien firme Ajuste los tornillos en la placa posterior Siga con el paso 4 Conexi n al bloque de terminales 3 2 Entrada lateral del cableado el ctrico IMPORTANTE La entrada del cableado el ctrico puede realizarse desde la derecha o la izquierda Antes de comenzar decida cu l utilizar La unidad est dise ada para tener un solo punto de entrada lateral del cableado el ctrico NOTA Si elije la entrada lateral deber perforar un quinto orificio en la pared Aseg rese de trabajar en el lado correcto para la instalaci n La salida del cuerpo principal debe coincidir con el soporte de la placa posterior Una vez que quita el panel de salida del cuerpo principal no podr cambiar de lado Izquierda Aseg rese de trabajar solo del lado de la tapa que ha elegido para ubicar el punto de entrada del cableado el ctrico Use alicates para cortar cuidadosamente solo un panel de salida marcado previamente del lado correcto del cuerpo principal Alinee con una de las esquinas y separe una parte inicial del panel Alinee con la otra esquina y separe la segunda parte del panel Separe toda la pieza desde el centro Despu s de separar limpie el exceso de pl stico Perfore 10 Derecha 5 PRECAUCI N No utilice la placa posterior c
16. ral Siga las instrucciones pertinentes NOTA Este producto no est recomendado para su montaje en paredes de superficie porosa por ejemplo de yeso sin una protecci n contra salpicaduras para evitar la p rdida de color en la pintura o los da os en las paredes no protegidas Se encuentra disponible un panel trasero de Dyson para este producto la cara frontal Las medidas recomendadas de las alturas se indican desde el piso Altura para un hombre adulto 51 pulgadas Altura para una mujer adulta 50 pulgadas Altura para un usuario en silla de ruedas 50 pulgadas Altura para un ni o de 5 a 8 a os 36 5 pulgadas Altura para un ni o de 8 a 11 a os 40 5 pulgadas Altura para un ni o de 11 a 14 a os 43 5 pulgadas PRECAUCI N No utilice la placa posterior como gu a al realizar las perforaciones Aseg rese de que no haya ninguna tuber a de gas agua aire ni cables el ctricos alambres o conductos directamente detr s de la zona de montaje perforaci n 1 Seleccione la altura adecuada Estas son alturas recomendadas pero es posible que deban adaptarse a cada instalaci n en particular 2 Los espacios m nimos son 1 2 pulgadas en la parte superior 8 7 pulgadas en los laterales No debe haber obstrucciones entre la unidad y el piso Mida la ubicaci n en la pared Si la entrada del cableado el ctrico se realiza desd
17. s y las normas federales estatales y locales aplicables incluso las regulaciones relacionadas con la construcci n ign fuga e Sila entrada de cableado el ctrico se realiza desde la parte lateral se debe asegurar mediante un conducto de pl stico o metal flexible y accesorios indicados que se ajusten al soporte lateral El conducto y los accesorios deben cumplir las normas locales y nacionales No utilice un conducto de metal s lido Aseg rese de que el conducto y los cables sean lo suficientemente largos como para conectarse a la placa posterior y al bloque de terminales e Al colocar el cableado en la placa posterior el largo m ximo de aislamiento del cable para tirar es de 0 25 pulgadas e La unidad necesita un disyuntor de 15 amperes con una l nea exclusiva y neutra SEGURIDAD A sle la alimentaci n el ctrica antes de la instalaci n o de realizar el mantenimiento INSTALACI N Aseg rese de que la unidad se instale conforme todos los c digos y normas de construcci n La unidad debe montarse en una pared plana vertical que sea capaz de soportar el peso total de la unidad Use los accesorios tal como se detalla en esta gu a de instalaci n Aseg rese de que no haya ninguna tuber a de gas agua aire ni cables el ctricos alambres o conductos directamente detr s de la zona de montaje perforaci n Dyson recomienda el uso de ropa gafas y materiales de protecci n al instalar o reparar seg n sea necesario S
18. unprotected walls A back panel for this product is available from Dyson 15 16 to top of fascia Recommended height measurements are from the floor 51 adult male height 50 adult female height 50 wheelchair user height 36 5 children 5 8 years old height 40 5 children 8 11 years old height 43 5 child 11 14 years old height CAUTION Do not use the backplate as a guide when drilling Ensure no pipe work gas water air or electrical cables wires or ductwork are located directly behind the drilling mounting area 1 Select the appropriate height Recommended heights are shown but may need to be adjusted for each individual installation 2 Minimum clearances are above 1 2 sides 8 7 There should be no obstruction between the unit and the floor 3 Measure the location on the wall If electrical wiring entry is to be from the rear the electrical wiring from the wall must align with rear electrical wiring entry point in the backplate Mark the location on the wall with a pencil Use the backplate to mark the locations for the four fixing points Drill holes Fix the optional back panel if required 3 1 Rear electrical wiring entry ES ed YX Y O Primary fixing locations x4 Do not use countersunk screws Fix
Download Pdf Manuals
Related Search
Related Contents
Heath Zenith 3035466 (AC-6180) User's Manual Liebert PEX Condenser Technical Manual Manual de uso y cuidado Guide d`utilisation du logiciel GWERN Version 7 33-550型 33-551型 33-552型 33-553型 33-554型 33-570型 33 StarTech.com C15HPSM wire connector 取扱説明書 - 加藤電機 Sun Cobalt™ RaQ™ XTR server appliance カメラマウント645D用 取扱説明書 Copyright © All rights reserved.