1. beckett SUBMERSIBLE PUMP OWNERS MANUAL 2 Models M250A amp M400A This pump is carefully inspected and tested to ensure both safety and operating performance The Pump is manufactured for continuous duty usage Failure to follow these instructions and warnings may result in pump damage and or serious injury Be sure to save this manual for future reference LISTED SUBMERSIBLE PUMP 552L WARNING N Risk of electrical shock this pump is supplied with a grounding conductor and a grounding type attachment plug To reduce risk of electrical shock be certain that it is connected only to a properly grounded grounding type receptacle To reduce the risk of electric shock use the pump with the flow control only on portable self contained fountains no larger than 5 feet in any dimension The National Electric Code requires that a ground fault circuit interrupter GFCI be used in the branch circuit supplying fountain pumps and other pond equipment See your electrical supplies dealer for this device Do not remove grounding pin from the plug Do not connect to any voltage other than that shown on the pump To reduce risk of electrical shock always disconnect from power outlet before handling pump or putting your hands into the water Do not let pump run dry Operate in non heated fresh water only Ensure that the pump is completely submerged for proper cooling to assure the pump s life Do not remove the pump by pulling the
2. cifique maximale est de 1 1 et dont le pH se situe entre 5 et 9 eau douce Les autres applications de liquide et les utilisations des temp ratures extr mes doivent tre approuv es l avance par Beckett La garantie ne s applique pas des dommages ou des d fauts caus s par des causes externes y compris l installation incorrecte ou d fectueuse ou la modification non autoris e la foudre les surtensions l utilisation excessive la mauvaise utilisation ou l utilisation anormale ou la mauvaise application y compris l utilisation d une mani re incompatible avec la fonction pr vue du produit Il incombe l acheteur de d terminer si le produit convient a l utilisation qu il entend en faire Si les produits sont endommag s dans le transport une r clamation doit tre d pos e aupr s du transporteur RECOURS En cas de d faut de conformit la garantie Beckett son gr r parera ou remplacera le produit ou la partie non conforme ou mettra un remboursement pour ce produit ou cette pi ce non conforme La r paration le remplacement ou le remboursement au gr de Beckett constitue le recours exclusif en cas de d faut de conformit la garantie Les r clamations au titre de la garantie doivent tre pr sent es au plus tard trois mois suivant l expiration de la p riode de garantie applicable ADMINISTRATION Les r clamations au titre de la garantie doivent tre pr sent es avec une preuve d achat ainsi que
3. n de la duraci n de las garant as impl citas as que las limitaciones o exclusiones arriba mencionadas pueden no aplican en su caso Esta garant a te da derechos legales espec ficos y usted a lo mejor tienes otros derechos que pueden variar de Estado a Estado PARA SUS RECORDS D a de Compra Numero de Modelo Nombre del Vendedor POR FAVOR GUARDE EL RECIBO EN EL CASO QUE REQUIERA SERVICIO DE GARANTIA GARANTIE LIMIT E Chaque produit de Beckett Corporation Beckett est garanti contre les d fauts de mati res et de fabrication pour la p riode de garantie applicable ainsi appel e dans les pr sentes indiqu e ci dessous Pour chaque produit la p riode de garantie commence la date de l achat par l acheteur initial Les p riodes de garantie sont les suivantes Produit P riode de garantie Produit P riode de garantie Mod les de pompes Rev tement S rie G S rie W S rie WF 2 ans PVG Sm lia cis lee 20 ans UL6500A XL 6500A Sn EPDM 40 mil 20 ans Autres mod les de pompes 1an PVC 20 mil ceinen 15 ans Etangs en poly pr form 15 ans Tous les autres produits Beckett 90 jours APPLICATION La garantie ne couvre que les produits Beckett install s et entretenus de la fa on appropri e et est limit e l application la temp rature normale de 32 F 86 F 0 C 30 C de fluides de pompage dont la gravit sp
4. le produit Beckett non conforme fret pay d avance l adresse suivante Beckett Corporation Customer Service Dept 3321 E Princess Ann Rd Norfolk Va 23502 t l phone 866 466 4319 Il faut obtenir de Beckett une autorisation par t l phone avant de retourner des produits ou des pi ces non conformes Beckett inspectera tous les produits ou toutes les pi ces afin de d terminer la cause du d faut de conformit avant d approuver la garantie FRAIS D INSTALLATION D ENLEVEMENT ET D EXP DITION La garantie ne couvre pas les frais associ s l installation l enl vement et l exp dition des produits faisant l objet de r clamations au titre de la garantie D NI ET LIMITATION LA GARANTIE ET LES RECOURS EXPLICITES NONC S CI DESSUS SONT EXCLUSIFS ET TIENNENT LIEU DE TOUTE AUTRE GARANTIE ET DE TOUT AUTRE RECOURS QU ILS SOIENT VERBAUX OU CRITS EXPLICITES OU IMPLICITES DANS TOUTE LA MESURE PERMISE PAR LA LOI BECKETT NIE EXPRESS MENT TOUTES LES GARANTIES IMPLICITES Y COMPRIS LES GARANTIES IMPLICITES DE QUALIT MARCHANDE ET D ADAPTATION UN USAGE PARTICULIER TOUTES GARANTIES IMPLICITES QUI NE PEUVENT TRE NI ES SONT LIMIT ES LA DUR E DE LA GARANTIE EXPLICITE APPLICABLE BECKETT N ACCEPTE PAS DE RESPONSABILIT AU DEL DES RECOURS EXPRESSEMENT INDIQU S DANS LA PR SENTE GARANTIE QUEL QUE SOIT LE CAS BECKETT NE SERA PAS RESPONSABLE DE DOMMAGES ACCESSOIRES OU INDIRECTS LA RESPONSABILITE GLOBALE DE BECKETT
5. AUX TERMES DE LA PR SENTE GARANTIE OU EN CE QUI CONCERNE TOUT PRODUIT COUVERT PAR CELLE CI QUELQUE SOIT LA TH ORIE JURIDIQUE INVOQUEE NE DOIT PAS DEPASSER LE PRIX D ACHAT PAYE POUR LE PRODUIT NON CONFORME LES LIMITATIONS CONTENUES DANS LE PRESENT PARAGRAPHE NE S APPLIQUENT PAS AUX LESIONS CORPORELLES Certains Etats ne permettant pas l exclusion ou la limitation de dommages accessoires ou indirects ou les exclusions ou les limitations touchant la dur e d une garantie implicite les limitations ou les exclusions pr c dentes ne s appliquent peut tre pas vous La pr sente garantie vous accorde des droits juridiques particuliers mais vous jouissez peut tre galement d autres droits qui varient d un tat l autre POUR VOS DOSSIERS Date de l achat Num ro du mod le Nom du d positaire VEUILLEZ GARDER LE RE U EN CAS DE RECOURS A LA GARANTIE BECKETT CORPORATION 8321 E Princess Ann Rd Norfolk Va 23502 www beckettpumps com Toll Free 1 866 466 4319 O 2010 BECKETT CORPORATION All Rights Reserved Importador SERVICIOS HOME DEPOT S A de C V RICARDO MARGAIN ZOZAYA 555 EDIFICIO A FRACC PARQUE CORP SANTA ENGRACIA SAN PEDRO GARZA GARC A NUEVO LE N C P 66267 TEL 81 5570 00
6. UIDE D UTILISATION de la POMPE SUBMERSIBLE D beckett POMPES M250A et M400A Cette pompe est soigneusement inspect e pour v rifier leur s ret et leur bon fonctionnement dans des bassins et des fontaines Ils sont manufactur s pour l utilisation de devoir continu Il faut cependant suivre les instructions et directives suivantes sous peine de blessures ou de dommages caus s la pompe Assurez vous d avoir lu ce guide et de le conserver pour consultation ult rieure TED SUBMERSIBLE PUMP 552L AVERTISSEMENT A Risques d lectrocution Cette pompe est munie d un prise de terre et d une fiche de raccordement avec mise la terre Ne branchez l appareil qu une prise ad quatement mise la terre afin d viter les risques de chocs lectriques Les risques de chocs lectriques employez la pompe avec la commande d coulement seulement sur les fontaines portatives de contained pas plus en grande partie que 5 pieds dans n importe quelle dimension Le National Electric Code le Code National de L lectricit exige qu un disjoncteur de fuite la terre GFCI soit utilis dans le circuit de d rivation alimentant les pompes pour fontaine ou autre quipement pour bassins Consultez votre revendeur de fournitures lectriques ce sujet Ne retirez pas la broche de mise la terre de la fiche Ne branchez pas l appareil une source de tension autre que celle sp cifi e sur la Pompe D branchez toujours l app
7. areil de la prise de courant avant de le manipuler ou de plonger vos mains dans l eau les risques de chocs lectriques Ne laissez pas la pompe courir sec Fonctionnez en eau doux non chauff seulement Assurez vous que la pompe est compl tement submerg e pour que le refroidissement appropri assure la vie de la pompe N enlevez pas la pompe en tirant le cordon de secteur Le cordon de secteur ne peut pas tre remplac la pompe devrait tre jet e si n importe quels dommages se produisent Afin d viter que l eau ne s coule sur le cordon et ne s infiltre dans la prise de courant le cordon doit former une boucle sous la prise formant ainsi une boucle d gouttement Boucle D gouttement AU LA SEE a Commande D coulement Tournante Cr pine D Entr e Roue Ailettes ENTRETIEN MISE EN GARDE D branchez toujours la Pompe avant de la manipuler ou de proc der des travaux d entretien SI LA POMPE NE FONCTIONNE PAS V RIFIEZ CE QUI SUIT e V rifiez le disjoncteur et essayez une autre prise de type disjoncteur de fuite la terre GFCI pour vous assurer que la Pompe est aliment e en courant e V rifiez d charge de la Pompe roue ailettes et tuyaux pour obstructions e V rifiez la cr pine d entr e d air pour vous assurer qu elle n est pas colmat e e Rincez avec de l eau pour enlever n importe quel habillage d algues e Pour n
8. es you specific legal rights and you may also have other rights that vary from State to State FOR YOUR RECORDS Date of Purchase Model Number Name of Dealer PLEASE KEEP RECEIPT IN CASE OF WARRANTY SERVICE GARANTIA LIMITADA Cada uno de los producto de Beckett Corporation Beckett esta garantizado por el Periodo de Garantia como se define en esta garantia que se menciona abajo contra defectos en material y manufactura El Periodo de Garantia para cada producto comienza en el dia de compra por el comprador original El Periodo de Garantia es el siguiente Tipo de Producto o Nombre Periodo de Garantia Tipo de Producto o Nombre Periodo de Garantia Modelos de Bombas Material Linear Serie G Serie W Serie WF 2 a os SON VG En r 20 a os 2 a os 40 Mil EPDM UL6500A XL 6500A 20 a os Otros modelos de Bombas 1 a o 20 mil PVC 15 a os Estanques de Poly Pre Formados 15 a os Todos los dem s productos Beckett 90 d as APLICACI N La garant a nicamente cubre los productos Beckett que hayan sido correctamente instalados y mantenidos y se limita a la aplicaci n de fluidos para bombas a una temperatura normal 32 F a 86 F 0 C a 30 C con una la especificaci n gravitacional de hasta 1 1 y con un pH dentro del rango de 5 a 9 agua fresca Cualquier otra aplicaci n de l quidos o uso de temperaturas extremas debe ser aprobado previamente por Beckett La garan
9. ettoyer la r gion de roue ailettes Tournez le logement 45 dans le sens contraire des aiguilles d une montre Tenez le grand logement circulaire et tirez le directement dehors Tourner la roue ailettes la main pour assurer qu il peut tourner librement e Employez un courant d eau pour enlever n importe quels d bris e Un entretien mensuel prolonge la dur e de service de la Pompe HAUTEUR DE REFOULEMENT MAX m LIMITED WARRANTY Each Beckett Corporation Beckett product is warranted to be free from defects in material and workmanship for the applicable Warranty Period herein so called set forth below The Warranty Period for each product commences on the date of purchase by the original purchaser The Warranty Periods are as follows Product Type or Name Warranty Period Product Type or Name Warranty Period Pump Models Waterfall Weir amp Skimmer 5 Years G Series W Series WF Series 2 Years Liner Material UL6500A XL 6500A 35 MP VO ses ensure deve earner dessa pees 20 Years Other Pump Models PA 40 mil EPDM 20 Years Pre Formed Poly Ponds 20 mil PVC 15 Years All Other Beckett Products 90 days APPLICATION The warranty covers only properly installed and maintained Beckett products and is limited to application at normal temperature 32 F to 86 F 0 C to 30 C pumpi
10. ll be inspected to determine cause of failure before warranty is approved INSTALLATION REMOVAL AND OR SHIPPING CHARGES The warranty does not cover any costs associated with the installation removal or shipping of products subject to warranty claims DISCLAIMER AND LIMITATION THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE FULL EXTENT PERMITTED BY LAW BECKETT EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED ALL SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY BECKETT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN THIS WARRANTY IN NO EVENT SHALL BECKETT BE LIABLE OR RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES BECKETT S AGGREGATE LIABILITY UNDER THIS WARRANTY OR WITH RESPECT TO ANY PRODUCT COVERED HEREBY UNDER ANY LEGAL THEORY SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE NONCONFORMING PRODUCT THE LIMITATIONS CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO INJURY TO THE PERSON Some States do not allow the exclusion or limitation of incidental or consequential damages or exclusions or limitations on the duration of an implied warranty so the above limitations or exclusions may not apply to you This warranty giv
11. mplazado En caso de da os al cable toda la bomba debe ser desechada Al retirar la bomba del agua s quela siempre cuidadosamente para impedir que el agua corra por el cable e ingrese en el tomacorriente TEL 81 557000 Importador SERVICIOS HOME DEPOT S A de C V Lazo De Goteo RICARDO MARGAIN ZOZAYA 555 EDIFICIO A FRACC PARQUE CORP SANTA ENGRACIA SAN PEDRO GARZA GARC A NUEVO LE N C P 66267 QUI Descarga Impulsor Control de Flujo que Rota Entrada de la Pantalla Sos fee MANTENIMIENTO CUIDADO Desconecte siempre de la toma el ctrica antes de tocar la Bomba SI LA BOMBA NO FUNCIONA REVISE LO SIGUIENTE e Revise el fusible del circuito y pruebe otro tomacorriente GFCI para asegurarse de que la Bomba recibe alimentaci n el ctrica e Revise la boca de descarga impulsor y la tuber a de la Bomba para asegurarse de que no contiene obstrucciones o estrangulamientos e Revise el filtro de malla de entrada para asegurarse e Limpie con un chorro de agua para quitar cualquier acumulaci n de las algas e Limpiar el rea del Impulsor gire la tapa del impulsor 45 en el sentido contrario de las agujas del reloj y jale derecho hacia fuera Haga girar el impulsor a mano para comprobar que pueda rotar libremente e Use un cepillo peque o con un chorro de agua para limpiar dentro e Mantenimiento en cada mes le ayudara que le dure mas la Bomba G
12. ng fluids with a specific gravity up to 1 1 and with a pH range of 5 to 9 fresh water Other liquid applications and extreme temperature uses must be approved in advance by Beckett The warranty does not apply to or cover damages or defects caused by external causes including but not limited to improper or faulty installation or unauthorized modification lightning electrical surges abuse misuse or abnormal use or misapplication including use in a manner inconsistent with the product s intended function The purchaser is responsible for determining the suitability of the product for its intended use If products are damaged in transit a claim should be filed with the carrier REMEDY If there has been a failure to conform to the warranty Beckett will at Beckett s option repair replace or issue a refund for the particular nonconforming product or part Repair replacement or refund at Beckett s option is the exclusive remedy in the event of a failure to conform to the warranty Warranty claims must be made within 3 months after expiration of the applicable Warranty Period ADMINISTRATION Warranty claims must be made by returning the nonconforming Beckett product freight prepaid along with proof of purchase to Beckett Corporation Customer Service Dept 3321 E Princess Ann Rd Norfolk Va 23502 Telephone 866 466 4319 authorization from Beckett is required prior to returning nonconforming products or parts All products or parts returned wi
13. power cord Power cord cannot be replaced pump should be discarded if any cord damage occurs Ensure that the electrical cord loops below the electrical outlet to form a Drip Loop This will prevent water from running down the cord into the electrical outlet Drip Loop She i a C Impeller Discharge Rotating Flow Control Intake Screen MAINTENANCE CAUTION Always disconnect from the electrical outlet before handling the Pump IF THE PUMP FAILS TO OPERATE CHECK THE FOLLOWING e Check the circuit breaker and try another GFCI protected outlet to ensure the Pump is getting electrical power e Check the pump discharge impeller and tubing for obstructions Check the intake screen to ensure it is not clogged Flush with water to remove any algae build up To clean the Impeller area rotate the volute 45 counter clockwise and pull it straight out Rotate the impeller by hand to ensure that it can spin freely Use a stream of water to remove any debris Monthly maintenance will add to your Pump s life MANUAL del PROPIETARIO de la BOMBA SUMERGIBLE beckett Modelos M250A y M400A Series Esta bomba se ha examinado y probado cuidadosamente para seguridad y funcionamiento Fabricada para uso continuo Sin embargo el no seguir las instrucciones y advertencias de este manual puede dar como resultado que la bomba sufra da os y o que se produzcan lesiones graves A
14. s ser n inspeccionados para determinar la causa de la falla antes de que se apruebe la garant a INSTALACI N REMOCI N Y O GASTOS ENV OS La garant a no incluye gasto asociados con la instalaci n remoci n o flete de los productos sujetos a los reclamos bajo garant a RENUNCIAS Y LIMITACIONES LA GARANT A EXPRESA Y LOS REMEDIOS DESCRITOS ARRIBA SON LOS NICOS Y EN LUGAR QUE CUALQUIER OTRA GARANT A O REMEDIOS SEAN ORALES O ESCRITOS EXPRESOS O IMPL CITOS DE LA MANERA MAS AMPLIA QUE PERMITA LA LEY BECKETT DE MANERA EXPRESA RENUNCIA CUALQUIER Y TODAS LAS GARANT AS IMPL CITAS INCLUYENDO SIN LIMITACI N ALGUNA LAS GARANT AS IMPL CITAS DE COMERCIALIDAD Y USO PARA UN FIN ESPECIFICO SI LAS GARANT AS IMPL CITAS NO PUEDEN SER RENUNCIADAS TODAS LAS GARANT AS IMPL CITAS EST N LIMITADAS A LA DURACI N DE LA GARANT A EXPRESA APLICABLE BECKETT NO ACEPTA RESPONSABILIDAD SUPERIOR A LOS REMEDIOS MENCIONADOS DE MANERA EXPRESA POR ESTA GARANT A EN NING N CASO BECKETT SER CULPABLE O RESPONSABLE POR DA O INCIDENTALES O CONSECUENCIALES LA RESPONSABILIDAD AGREGADA DE BECKETT S BAJO ESTA GARANT A O RESPECTO A LOS PRODUCTOS CUBIERTOS POR LA MISMA BAJO CUALQUIER TEOR A LEGAL NO PODR N EXCEDER DEL PRECIO DE COMPRA PAGADO POR EL PRODUCTO INADECUADO LAS LIMITACIONES DE ESTE P RRAFO NO APLICARAN A DA OS A PERSONAS Algunos Estados no permiten la exclusi n o limitaci n de da os incidentales o da os consecuenciales o la exclusi n o limitaci
15. segurese de leer y conservar este manual para consultas futuras SUBMERSIBLE PUMP 552L ADVERTENCIA Riesgo de choque el ctrico esta bomba se proporciona con un conductor de tierra y un enchufe con conexi n a tierra Para reducir el riesgo de choques el ctricos ench fela Unicamente a un tomacorriente conectado a tierra Para reducir el riesgo de choques el ctricos use la bomba que tiene control de flujo solamente en fuentes portatiles contenidas no mas grandes de 1 52 m en cualquier dimension El C digo El ctrico Nacional de los Estados Unidos requiere el uso de un disyuntor de circuitos en caso de fugas a tierra GFCI que debe conectarse a la rama del circuito el ctrico que abastece las bombas de fuentes y otro equipo para estanques Consulte a su proveedor de productos el ctricos acerca de este dispositivo No retire la clavija de tierra de la enchufe No conecte la bomba a voltajes distintos de los especificados en la bomba Para reducir el riesgo de choques el ctricos desconecte siempre la bomba de su tomacorriente antes de manipularla o de introducir las manos en el agua No permita que la bomba funcione en seco Haga funcionar la bomba nicamente en agua dulce no calentada Aseg rese de que la bomba quede completamente sumergida para garantizar su enfriamiento y prolongar su duraci n No extraiga la bomba tirando del cable de alimentaci n el ctrica El cable de alimentaci n el ctrica no puede ser ree
16. t a no aplica o cubre da os o defectos causados por causas externas incluyendo pero no limit ndose a instalaci n inapropiada o defectuosa o modificaciones no autorizadas tormentas el ctricas cambios de corriente el ctrica abuso uso no recomendado uso anormal o aplicaci n incorrecta incluyendo el usar el producto de manera inconsistente con su finalidad El comprador es responsable de determinar la conveniencia del producto para el uso intencionado Si el producto se da a en transito cualquier queja o demanda deber ser presentada con el transportista REMEDIOS Si ha existido una falta en la garant a Beckett bajo su propia discreci n optar por reparar remplazar o otorgar una devoluci n por los producto o parte particular que no cumpla con ella Reparar remplazar o devolver a la nica discreci n de Beckett ser el nico remedio en el caso que no se conforme a la garant a Los reclamos amparados por la garant a deben ser hechos dentro de los 3 meses siguientes a la expiraci n del Periodo de Garant a ADMINISTRACI N Los reclamos bajo la garant a deber n ser hechos regresando el producto defectuoso con gastos de env o prepagados con comprobante de compra a Beckett Corporation Customer Service Dept 3321 E Princess Ann Rd Norfolk Va 23502 tel fono 866 466 4319 Autorizaci n telef nica por parte de Beckett es requerida antes de regresar cualquier parte o producto inadecuado Todos los productos o partes devuelta
Download Pdf Manuals
Related Search
Related Contents
Répondre aux besoins de vos patients Cuecehuevos Egg Central® CEC-10 INSTRUCCIONES & LIBRO TAFCO WINDOWS NU2-138V-I Instructions / Assembly SISC for Seasoned Schemers HardingFPA-X User`s Manual Barrera inmaterial de seguridad tipo 4 Philips LCD Monitor Electronic User`s Manual User Manual - Elite Cruises and Travel Dossier pédagogique à télécharger - Opéra Théâtre de Saint Phonix SOXE3GPW mobile phone case Copyright © All rights reserved.