Home
Quick Guide
Contents
1. Version 1 DK August 2013 QUICK GUIDE This quick guide does not replace the installation manual and the compulsory technical training course for installers DIP switch 10 should be set to ON to let the acoustic alarm activate in case of a fault REMEMBER to set the fog time on DIP switch 2 3 and 4 Table for fog time is printed inside the steel cover About avoiding accidental firing The European Norm for fog security prescribes a method to avoid accidental firing of fog e g during service However the above diagram does not include this step as the method used is dif ferent from alarm installer to alarm installer La presente gu a r pida de instalaci n en ning n caso sustituye el manual de instalaci n ni el curso de capacitaci n t cnico obligatorio para instaladores El DIP Switch 10 debe colocarse en posici n ON para dejar las se ales ac sticas activadas para avisar en caso de fallo Recuerde configurar los tiempos de disparo de la Niebla mediante los DIP Switch 2 3 y 4 Las diferentes configuraciones de tiempos de disparo viene descrita en la cara interior de la carcasa del Generador Evitar disparos accidentales La Normativa europea exige una metodolog a para evitar disparos accidentales en relaci n a la Niebla de Seguridad por ejemplo durante el mantenimiento Sin embargo el diagrama no incluye este paso ya que la metodolog a de cada instalador es diferente Denne quick guide erstatter ikke
2. GB Check that the phase and zero wires are connected correctly Compruebe que la fase y el neutro est n conectados correctamente Check at fase og 0 leder tilsluttes korrekt Tr k evt v skedunk fri af lynkobling for at undg utilsig tet affyring Lad kablet v re tilsluttet Check correct polarity When the alarm is disarmed a d must be shown in the display When the alarm is armed the d must disappear because the input must be dead Compruebe la polaridad correcta Cuando el sistema de alarma esta desconectado debe aparecer una d en el display de la unidad Cuando la alarma est conectada la d debe desaparecer pues la entrada estar libre de voltaje Kontroller korrekt polarisering Nar alarmen er frakoblet skal der komme et d i displayet Ved tilkoblet alarm forsvinder d da indgangen skal v re sp ndingsl s In the event of an alarm signal a P must be shown in the display In the event of malfunction check that 12 V in and out is working and that DIP switch 6 is set correctly Compruebe la se al desde el sistema de alarma en caso de robo El display del Generador debe mostrar una P En caso del mal funcionamiento revise la entrada de 12 V y que el DIP Switch 6 est colocado correctamente Kontroller korrekt polarisering Ved alarmsignal skal der komme et P i display Ved fejl kontroller om 12V til og fra fungerer o
3. manualen og det obligatoriske teknikkursus for installat rer DIP 10 b r v re ON s den indbyggede bibber akustisk signal for fejlmelding er tilsluttet HUSK at indstille en t getid p DIP switchene 2 3 og 4 Tabel for t getid findes indvendigt i maskinens st lkabinet Om sikring mod utilsigtet affyring Den europ iske norm for t gesikring foreskriver en metode til sikring mod utilsigtet affyring af t gen fx under service En s dan foranstaltning er ikke taget med i diagrammet da me toderne er mange og individuelle fra alarminstallat r til alarminstallat r y gt WWW PROTECTGLOBAL COM UNBEATABLE FOG SECURITY PROTEC T d di Closed in daytime Opens with alarm Zone Fault Alarm System Alarm Signal Fog Cannon Fault Rly Fluid Rly Scan and get manuals Escanee para descargar los manuales Scan og hent manualer 600i 1100i 2200i QUMULUS Action Acci n Handline GB Connect the unit to 230VAC Earth It will take the unit 15 25 min to warm up to operating temperature Conectar el dispositivo a 230VAC Tierra Dependiendo del modelo de Generador necesitar entre 15 y 25 minutos para llegar a la ptima temperatura de funcionamiento DK Maskinen tilsluttes 230VAC Jord Det tager 15 25 DIS GB min at varme op til driftstemperatur Connect the disable input to the 12V DC signal from the alarm system When the alarm is disar med DIS must be energised When the alarm is set
4. armed the 12V DC signal must disappear Se puede conectar a DIS una se al de 12V desde el sistema de alarma Al desactivar la alarma DIS tiene que recibir estos 12V y as se desactivar el Generador Cuando se arme la alarma y desaparezcan los 12 V de esta entrada la unidad estar preparada para disparar Disable indgang tilsluttes 12V DC signal fra alarm systemet Nar alarmen er frakoblet skal der vaere sp nding p DIS N r alarmen tilkobles skal 12V DC sp ndingen brydes PRIM GB SEC GB The primary input must be supplied with 12V DC from the alarm system If the alarm signal is closed in the event of burglary DIP 6 is set to ON If the alarm signal is opened DIP 6 is set to OFF La entrada a PRIMARIO debe recibir 12V de corriente continua desde el sistema de alarma En caso de robo si la se al del sistema de alarma est cerrada el DIP Switch 6 debe estar en posici n ON Si la se al del sistema de alarma est abierta el DIP Switch 6 ha de ponerse en posici n OFF Prim r indgang forsynes med 12V DC fra alarmsystemet Hvis alarmsignalet sluttes ved indbrud s ttes DIP 6 ON hvis alarmsignalet brydes s ttes DIP 6 OFF Connect the secondary input to PIR verifying sensor PIR is supplied with 12V DC from the Fog Cannon s built in 12V supply Feed 12V through the PIR contact assembly and connect to SEC Jump 12V to SEC on the Fog Cannon s terminal block The PIR contact as
5. g om DIP switch 6 st r rigtigt Check correct polarity When the PIR is activated an S must be shown in the display In the event of malfunction check that the PIR is working correctly and that DIP switch 7 is set correctly Compruebe la polaridad correcta Cuando el PIR se activa debe mostrarse una S en el display de la unidad En caso de mal funcionamiento compruebe que el PIR funciona correctamente y que el DIP Switch 7 est puesto correctamente en OFF Kontroller korrekt polarisering Nar PIR aktiveres skal der komme et S i displa yet Ved fejl kontroller om PIR virker korrekt og om DIP switch 7 st r rigtigt Check that an A is shown in the display Compruebe si se muestra A en el display de la unidad Kontroller at der kommer et A i displayet The display will scroll continuously typically H r d A b A t c see meanings in the manual or on the inside of the cover screen In aar to fire a fog the following must be displa yed r A P S Meaning r The unit is warm A P S All triggers are active and DIS d is not blocking the machine El display de la unidad mostrar de forma c clica los siguientes c digos H r d A b A t c Vea stos c digos en el manual o en el interior de la carcasa del Generador Para realizar el disparo de la Niebla el display debe mostrar r A P S Significado r La unidad est preparada para d
6. isparar A P S Todas las entradas est n activas y DIS d no bloquea la m quina El Generador entrar en funcionamiento typisk H r d A b A t c se betydningen i manual eller indvendig i st lkabinettet For at kunne affyre tage skal f lgende visning v re tilstede r A P S Det betyder r Maskinen er varm A P S Alle triggere er aktive og d ma ikke v re tilstede n r alarmen er tilkoblet Before you finish the installation also consider the need and method of connecting the outgoing signals The diagram on the reverse page only shows the principle of the relay connections These will depend on what the individual alarm system is able to handle Tamper circuit is not shown The Fog Cannon has a normal tamper switch which can be integrated in a usual tamper circuit Always remember to make a full scale test to check that the alarm system fog security system and PIR sensor are working together and to ensure that the amount of fog will cover the secured area as expected Antes de finalizar la instalaci n considere la posibilidad de conectar al sistema de alarma las se ales de estado salientes del Ca n En el diagrama en la p gina posterior se indican las principales conectividades Estas depender n de la configuraci n de cada sistema de alarma instalado por cada instalador No se muestra el circuito de Tamper El Generador de Niebla tiene un interruptor normal Tamper que puede ser integrado en un circuit
7. o Tamper com n Recuerde siempre hacer una prueba completa de disparo para comprobar que el sistema de alarma el dispositivo de Niebla de Seguridad y el sensor PIR se activar n y funcionar n de forma ptima en caso de robo Adem s aseg rese de que la duraci n y la configuraci n del disparo generar suficiente cantidad de Niebla como para cubrir el rea a proteger F r installationen afsluttes b r man overveje tilslutning af udg ende signaler fra rel erne Diagrammet p bagsiden viser principperne i tilslutningerne detaljerne vil afh nge af det enkelte alarmsystem og dets muligheder for at h ndtere de aktuelle signaler Tamper forbindelsen vil ligeledes afh nge af anl ggets forskellige enheder Vi anbefaler p det kraftigste at overf re t gekanonens 3 rel udgange til alarmanl g get Husk altid at afslutte med en fuldskalatest for at sikre sammenspillet mellem alarmsystem t gekanon og PIR sensor
8. sembly has a normal break function Set DIP 7 to OFF Conectar la entrada a SECUNDARIO desde el PIR sensor de detecci n pasivo El PIR puede ser alimentado por la salida de 12V de corriente continua del propio Generador A falta de los 12V en el terminal SEC el Ca n de Niebla entrar en funcionamiento La posici n del DIP Switch 7 ser en OFF Sekund r indgang tilsluttes PIR verificerende sensor PIR forsynes med 42V DC fra gede 12 Volt forsyning 12V f res igennem PIR ens kontakts t og sluttes til SEC 12V luses over til SEC pa t gekanonens klemraekke PIR ens kontaktsaet har normal brydefunktion og DIP 7 s ttes til OFF t gekanonens indbyg ARM GB E DK This input is normally not used Set DIP 5 to OFF Esta entrada normalmente no se utiliza Mantenga el DIP Switch en posici n OFF Denne indgang anvendes normalt ikke og DIP 5 s ttes til OFF The unit is ready for testing when it is fully war med up Remember to set a fog time on the DIP switches 2 3 and 4 La unidad estar lista para realizar el disparo cuando se haya calentado y haya alcanzado la temperatura adecuada Recuerde configurar los tiempos de disparo con los DIP Switch 2 3 y 4 Maskinen er klar til test n r den er fuldt opvar met Husk at vaeskedunken skal v re korrekt fastgjort i lynkoblingen Displayet k rer en kontinuerlig rulletekst Check Comprobaciones Kontrol
Download Pdf Manuals
Related Search
Related Contents
YT-1000R English.hwp MODE D`EMPLOI - Roland Central Europe Cliccate qui per un nuovo BenQ MP724 DLP User Guide Manual Design House 753251 Use and Care Manual KULINARISK Manual de Usuario Vanguardia en Tecnología S.A. de C.V. Mallette Des femmes et des hommes Copyright © All rights reserved.
Failed to retrieve file